SPECIFICATIONS MEASUREMENT SOLUTIONS

4" to 20" Sentry Series


Bulletin SS02001 Issue/Rev. 1.2 (7/14)
We put you first.
And keep you ahead.

SMITH METER TURBINE METERS


The Smith Meter Sentry Series Turbine Meter is a
rimmed, rotor-type meter with helical blades. Sentry Series
Turbine Meters utilize both an upstream and downstream
stator and have tungsten carbide bearings with a hydrody-
namic thrust balance system. They provide highly accurate
measurement required for custody transfer of petroleum
liquids such as crude oil and refined products in larger
pipelines.

FEATURES
Rimmed rotor for durability and high resolution Model Code K2DG
pulse output
Helical blades for a streamlined flow pattern
less susceptible to cavitation OPERATING SPECIFICATIONS
All Stainless Steel wetted parts for corrosion- Linearity4
free service 0.15% linearity over normal flow range.
Tungsten carbide bearings provide long life on 0.10% linearity over 5:1 flow range.
low lubricity liquids 0.07% linearity over 5:1 flow range.
Hydrodynamic thrust balance system to mini-
mize friction and wear on thrust bearings which
Repeatability
allows for long service life and high accuracy
Per API MPMS or OIML R-117-1.
NACE Compliance to MR0175/ISO 15156-1

FLOW RANGE
OPTIONS Meter
Normal Flow Range3
Nominal K-Factor1
Units1 Min.
Sizes (Pulses/Unit) 5%
Bidirectional flow allows the meter to accurately Rate3
Max. Rate

register flow in either direction. BPH 150 1,500 2,100


4"2
Multiple pickup coils are used when direction sensing m3/h 24 240 13,210
or pulse security is required. A third pickup coil is avail- BPH 250 2,500 1,050
6" LF2
m3/h 40 400 6,615
able to drive auxiliary equipment, such as a back-up
BPH 400 4,000 1,050
counter or prover. 6" 2
m3/h 64 635 6,615
0.10% and 0.07% linearity available. BPH 750 7,500 525
8"2
High-resolution (HR) output available on 4" through m3/h 120 1,195 3,300
8" meters to increase the pulse output per unit volume BPH 1,200 12,000 525
10"
to allow proving with a smaller-size pipe prover1. m3/h 191 1,910 3,300
BPH 1,800 18,000 265
12"
m3/h 286 2,860 1,670
1 Available with higher resolution (HR) pulse output than the BPH 2,700 27,000 105
16"
nominal K-factor: size 4" - x1.5; sizes 6" LF, 6", and 8" - x2 m3/h 430 4,295 662
2 Metric units are nominal and may not convert precisely. BPH 3,500 35,000 105
18"
3 For bidirectional flow, the minimum flow rate is 20% of the m3/h 557 5,565 662
normal maximum rate.
BPH 4,200 42,000 105
4 Linearities and pressure drops based on 0.82 sp. gr., 20"
1 mPas (1.5 cP) liquid. m3/h 668 6,680 662
Overspeed
MATERIALS OF CONSTRUCTION
130% of maximum flow rate for 5% duty cycle. Body 316 Series Stainless Steel
Flanges Carbon Steel
End Connections (Not Wetted) Optional: 304 Series Stainless Steel
Class 150, 300, 600, ANSI B16.5, 125-250 AARH Internals 300 Series Stainless Steel, Except 430
Stainless Steel Rotor Buttons
finish raised face (RF) flanges.
Bearings and Tungsten Carbide
Consult factory for higher working pressure or other types Thrust Washers
of flanges.

INSTALLATION
MAXIMUM WORKING PRESSURE
The meter must be mounted in a horizontal attitude (5)
- PSI (kPa)
within a suitable flow conditioning assembly and is rec-
ANSI Carbon Steel Flanges Stainless Steel Flanges
ommended that the meter be installed downstream of a
150 285 (1,965) 275 (1,896)
300 740 (5,102) 720 (4,964)
strainer for protection and upstream of the system control
600 1,480 (10,205) 1,440 (9,929) valve.
Refer to the installation manual MN02003 for full instructions.
METER OPERATING TEMPERATURE RANGE
Carbon Steel Stainless Steel
Meter with:
Flanges Flange APPLICATIONS
-20F to 225F -50F to 225F High Viscosity
Pickup Coil
-29C to 107C -46C to 107C
The flow range of turbine meters is reduced considerably
-20F to 158F -50F to 158F
Pickup Coil and Preamp when metering viscous liquids. The minimum flow rate
-29C to 70C -46C to 70C
Pickup Coil and Preamp -20F to 225F -50F to 225F must be increased as the viscosity increases. The follow-
with 24" Standoff -29C to 107C -46C to 107C ing relationships can be used to approximate the increase
Consult factory for temperatures outside noted ranges. (reduction in range) that will maintain the stated linearity.

Electrical Approvals Viscous Min. = Normal Min. x Viscosity (cP)


UL/CUL, Listed 557 N Class I Groups C and D; Class I, Rate Rate Meter Size (in)
Zone I, Group IIB; Class I, Zone I, AExd IIB T6 IP66;
UNL-UL ENCL. 4, CNL-CSA ENCL. 4; Tamb -50C to 70C Note: Caution should be used when dealing with liquids that
result in a viscous minimum rate greater than two times the
ATEX / IEC Ex normal, since variations in operating temperature can result in
PTB 08 ATEX 1034X, IEC Ex PTB 08.0040X substantial meter factor shifts.
Ex d IIC T6 Tamb = -40C to 70C IP66
Low Density
Essential Health and Safety Requirements When metering light hydrocarbons such as LPG or other
EN/IEC 60079-0: Electrical apparatus for potentially liquids with specific gravity less than 0.8, the minimum
explosive atmospheres general requirements flow range should be shifted upward. The amount of shift
EN/IEC 60079-1: Electrical apparatus for potentially can be approximated by multiplying the normal minimum
explosive atmospheres flameproof enclosures 'd' flow rate by the following factor:
EN 60529: Degrees of protection provided by
enclosures (IP code) Rate Increasing Factor = 0.9
EMC Compliance: (by Council Directive 2004/108/EC)
S
Electromagnetic Emissions: EN 61000-6-3
Electromagnetic Immunity: EN 55022 Where: S = The specific gravity of the liquid being metered.
IEC 61000-4-2: Electrostatic Discharge (ESD), Level 3+ The increased flow rate should not exceed the meter's
(8.0 kV by contact, 12 kV by air) overspeed flow rate.
IEC 61000-4-3: Radiated Electromagnetic Field, Level 3
(10 V/m)
IEC 61000-4-4: Electrical Fast Transient (Burst), Level 2
(1kV)
IEC 61000-4-5: Electrical High Energy Pulses (Surge),
Installation Class 3, Criterion B

2 Bulletin SS02001 Issue/Rev. 1.2 (7/14)


Minimum Back Pressure PICKUP COIL SPECIFICATIONS
In order to prevent cavitation, API M.P.M.S. Chapter 5
Type: Variable reluctance.
recommends a minimum back pressure according to the
following: Le Re

BP = (2 x P) + 1.25 Vp
Vo

Where: BP = Minimum back pressure


P = Pressure drop at maximum flow rate
VP = Absolute vapor pressure at operating
Electrical Characteristics
temperature
Effective Series Resistance (Re ): 1,020 (20%)
Effective Series Inductance (Le ): 450 mH @ 1,000 Hz
Example:
Minimum Open Circuit Voltage (Vo): 300 millivolts p/p at
6" Sentry at 4,000 BPH P = 6 psi.
minimum flow rate
Absolute vapor pressure of butane at operating
Maximum Transmission Distance: 2,000 ft (610 m) using
temperature - Vp = 50 psia.
#20 AWG two-conductor, shielded cable
Min. BP = (2 x 6) + 1.25 (50)
Notes: A preamplifier is recommended for remote instrumenta-
= 74.5 psi tion that does not have Common Mode Noise Rejection. See
Bulletin SS02012 for PA-6 Preamplifier Specifications.

Pressure Drop4
Flow - Cubic Meters per Hour
20 50 100 500 1,000 5,000 10,000
10
9.0
8.0 Data based on 0.8 sp. gr., 60
7.0 50
6.0
2.0 mPas (2.0 cP) viscosity.
40
5.0
4.0 30
25
3.0
F in

20
in
in

in
in
in
4 in

6 in

8 in
6L

10
12

16
18
20

2.0 15

P 10 P
PSI 9.0 kPa
1.0 8.0
0.9 7.0
0.8 6.0
0.7 5.0
0.6
4.0
0.5
0.4 3.0
2.5
0.3
2.0

0.2 1.5

1.0
0.9
0.8
0.1
100 500 1,000 5,000 10,000 50,000 100,000

Flow - Barrels per Hour

4 Linearities and pressure drops based on 0.82 sp. gr., 1 mPas (1.5 cP) liquid.

Bulletin SS02001 Issue/Rev. 1.2 (7/14) 3


CATALOG CODE
The following guide defines the correct Sentry turbine meter for a given application and the respective catalog code. This
code is part of the ordering information and should be included on the purchase order.

1 2 3 4 5 6 7 8 9 10 11
K 2 D F A 0 A 1 0 0 0

Position 1: Code 8 - MMRT with PA-11 and 1 Pickup Coil


K - Catalog Code 9 - MMRT with PA-11 and 2 Pickup Coils
Pickup Coil(s) with Online Diagnostics
Position 2: Product Line S - 1 Pickup Coil and AccuLERT6 XU
2 - Turbine Meter T - 2 Pickup Coils and AccuLERT6 XU
Extended Temperature Range with Preamplifier on
Position 3: Model 24-Inch Standoff
D - Sentry Series ANSI End Connections D - 1 Pickup Coil and 1 Preamplifier
J - 2 Pickup Coils and 2 Preamplifiers
Position 4: Size and Type Extended Temperature Range with Online Diagnostics
R - 4-Inch T - 8-Inch High Resolution on 24-Inch Standoff
V - 4-Inch High Resolution J - 10-inch E - 1 Pickup Coil and AccuLERT6 XU
F - 6-Inch Low Flow K - 12-Inch K - 2 Pickup Coils and AccuLERT6 XU
W - 6-Inch Low Flow, High L - 16-Inch Extended Temperature Range with Explosion Proof
Resolution Totalizer/Flow Rate Indicator on 24-Inch Standoff
G - 6-Inch M - 18-Inch
F - MMRT with PA-11 and 1 Pickup Coil
S - 6-Inch High Resolution N - 20-Inch
L - MMRT with PA-11 and 2 Pickup Coils
H - 8-Inch
Miscellaneous
Position 5: Pressure Class M - INVALCO 202D Totalizer with Pickup Coil
ANSI End Connections (ASME B16.5) N - INVALCO 202D Totalizer with Pickup Coil on 24-Inch
A - Class 150 Standoff
B - Class 300 X - Special
D - Class 600
Position 9: Testing / Linearity
Position 6: End Connections5
0 - Carbon Steel RF Flanges Linearity
F - 304 Stainless Steel RF Flanges 0 0.15%
1 0.10% (5:1 flow turndown)
Position 7: Internal Configuration
2 0.07% (5:1 flow turndown)
A - Unidirectional Flow, 430 Stainless Steel Buttons
B - Bidirectional Flow, 430 Stainless Steel Buttons 3 Special testing

Position 8: Pickup Coils and Preamplifiers Position 10: Compliance with Standards
Meter Mounted Junction Box(es) with 0 - UL/CUL Listed
0 - 1 Pickup Coil 3 - ATEX / IEC Ex Certified
1 - 1 Pickup Coil and Preamplifier 4 - ATEX / IEC Ex / PED7 Certified
2 - 2 Pickup Coils 5 - UL / CUL / CRN
3 - 2 Pickup Coils and 2 Preamplifiers
4 - 2 Pickup Coils and 1 Preamplifier Position 11: Specials
7 - 3 Pickup Coils and 2 Preamplifiers 0 - None
P - 3 Pickup Coils and 3 Preamplifiers X - Special - Specify
Pickup Coil(s) with Explosion Proof Totalizer/Flow Rate
Indicator

5 Low temperature (below -20F) requires stainless steel end connections.


6 The AccuLERT also provides dual channel preamplification and online diagnostics.
7 PED required for all European countries; equipment must be manufactured by Ellerbek, Germany facility.

4 Bulletin SS02001 Issue/Rev. 1.2 (7/14)


DIMENSIONS
Inches (mm) and Pounds (kg)

A
A
2 3" Explosion-Proof Box
(76)
2"
(51)

1" NPT B

Second pickup coil spaced


90 electrical degrees, +/- 60
degrees from first coil (optional)

Dimensions inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective
engineering drawings.

Class 150 Class 300 Class 600


ANSI ANSI ANSI
Size A B8 C Wt. C Wt. C Wt.
12.0 5.8 9.0 65 10.0 85 10.8 110
4"
(305) (149) (228) (30) (254) (38) (273) (50)
14.0 6.9 11.0 135 12.5 185 14.0 295
6"LF
(356) (175) (279) (61) (318) (84) (356) (134)
14.0 6.9 11.0 100 12.5 145 14.0 245
6"
(356) (175) (279) (45) (318) (66) (356) (111)
16.0 7.9 13.5 155 15.0 230 16.5 320
8"
(406) (201) (343) (70) (381) (104) (419) (114)
24.0 9.0 16.0 265 17.5 350 20.0 560
10"
(610) (228) (406) (120) (445) (159) (508) (294)
30.0 10.0 19.0 385 20.5 575 22.0 750
12"
(762) (253) (483) (175) (521) (261) (559) (340)
40.0 11.6 23.5 835 25.5 1,080
16"
(1,016) (294) (597) (379) (648) (490)
45.0 12.6 25.0 1,060 28.0 1,405
18" CF
(1,143) (320) (635) (481) (711) (638)
50.0 13.6 27.5 1,510
20" CF CF
(1,270) (345) (699) (686)

Note: Meter weights by flange class with one pickup coil and explosion-proof box. Add 5 lb (2.3 kg) for each additional pickup coil and
explosion-proof box.

8 Add 24" for a standoff when using a preamplifier for temperatures 158F to 225F (70C to 107C).

Bulletin SS02001 Issue/Rev. 1.2 (7/14) 5


We put you first.
And keep you ahead.

Revisions included in SS02001 Issue/Rev. 1.2 (7/14):


Page 1: Flow Range Normal Flow Range (Min. Rate) revised.
The specications contained herein are subject to change without notice and any user of said specications should verify from the manufacturer that the specications are currently
in effect. Otherwise, the manufacturer assumes no responsibility for the use of specications which may have been changed and are no longer in effect.
Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the Contact
Us link in the left-hand column.

USA Operation
1602 Wagner Avenue
Erie, Pennsylvania 16510 USA
P:+1 814.898.5000
FMC Technologies
Measurement Solutions, Inc. Germany Operation
500 North Sam Houston Parkway West, Smith Meter GmbH
www.fmctechnologies.com/measurementsolutions Suite 100 Regentstrasse 1
Houston, Texas 77067 USA 25474 Ellerbek, Germany
2014 FMC Technologies. All rights reserved. SS02001 Issue/Rev. 1.2 (7/14) P:+1 281.260.2190 P:+49 4101.304.0