FEATURES
Rimmed rotor for durability and high resolution Model Code K2DG
pulse output
Helical blades for a streamlined flow pattern
less susceptible to cavitation OPERATING SPECIFICATIONS
All Stainless Steel wetted parts for corrosion- Linearity4
free service 0.15% linearity over normal flow range.
Tungsten carbide bearings provide long life on 0.10% linearity over 5:1 flow range.
low lubricity liquids 0.07% linearity over 5:1 flow range.
Hydrodynamic thrust balance system to mini-
mize friction and wear on thrust bearings which
Repeatability
allows for long service life and high accuracy
Per API MPMS or OIML R-117-1.
NACE Compliance to MR0175/ISO 15156-1
FLOW RANGE
OPTIONS Meter
Normal Flow Range3
Nominal K-Factor1
Units1 Min.
Sizes (Pulses/Unit) 5%
Bidirectional flow allows the meter to accurately Rate3
Max. Rate
INSTALLATION
MAXIMUM WORKING PRESSURE
The meter must be mounted in a horizontal attitude (5)
- PSI (kPa)
within a suitable flow conditioning assembly and is rec-
ANSI Carbon Steel Flanges Stainless Steel Flanges
ommended that the meter be installed downstream of a
150 285 (1,965) 275 (1,896)
300 740 (5,102) 720 (4,964)
strainer for protection and upstream of the system control
600 1,480 (10,205) 1,440 (9,929) valve.
Refer to the installation manual MN02003 for full instructions.
METER OPERATING TEMPERATURE RANGE
Carbon Steel Stainless Steel
Meter with:
Flanges Flange APPLICATIONS
-20F to 225F -50F to 225F High Viscosity
Pickup Coil
-29C to 107C -46C to 107C
The flow range of turbine meters is reduced considerably
-20F to 158F -50F to 158F
Pickup Coil and Preamp when metering viscous liquids. The minimum flow rate
-29C to 70C -46C to 70C
Pickup Coil and Preamp -20F to 225F -50F to 225F must be increased as the viscosity increases. The follow-
with 24" Standoff -29C to 107C -46C to 107C ing relationships can be used to approximate the increase
Consult factory for temperatures outside noted ranges. (reduction in range) that will maintain the stated linearity.
BP = (2 x P) + 1.25 Vp
Vo
Pressure Drop4
Flow - Cubic Meters per Hour
20 50 100 500 1,000 5,000 10,000
10
9.0
8.0 Data based on 0.8 sp. gr., 60
7.0 50
6.0
2.0 mPas (2.0 cP) viscosity.
40
5.0
4.0 30
25
3.0
F in
20
in
in
in
in
in
4 in
6 in
8 in
6L
10
12
16
18
20
2.0 15
P 10 P
PSI 9.0 kPa
1.0 8.0
0.9 7.0
0.8 6.0
0.7 5.0
0.6
4.0
0.5
0.4 3.0
2.5
0.3
2.0
0.2 1.5
1.0
0.9
0.8
0.1
100 500 1,000 5,000 10,000 50,000 100,000
4 Linearities and pressure drops based on 0.82 sp. gr., 1 mPas (1.5 cP) liquid.
1 2 3 4 5 6 7 8 9 10 11
K 2 D F A 0 A 1 0 0 0
Position 8: Pickup Coils and Preamplifiers Position 10: Compliance with Standards
Meter Mounted Junction Box(es) with 0 - UL/CUL Listed
0 - 1 Pickup Coil 3 - ATEX / IEC Ex Certified
1 - 1 Pickup Coil and Preamplifier 4 - ATEX / IEC Ex / PED7 Certified
2 - 2 Pickup Coils 5 - UL / CUL / CRN
3 - 2 Pickup Coils and 2 Preamplifiers
4 - 2 Pickup Coils and 1 Preamplifier Position 11: Specials
7 - 3 Pickup Coils and 2 Preamplifiers 0 - None
P - 3 Pickup Coils and 3 Preamplifiers X - Special - Specify
Pickup Coil(s) with Explosion Proof Totalizer/Flow Rate
Indicator
A
A
2 3" Explosion-Proof Box
(76)
2"
(51)
1" NPT B
Dimensions inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective
engineering drawings.
Note: Meter weights by flange class with one pickup coil and explosion-proof box. Add 5 lb (2.3 kg) for each additional pickup coil and
explosion-proof box.
8 Add 24" for a standoff when using a preamplifier for temperatures 158F to 225F (70C to 107C).
USA Operation
1602 Wagner Avenue
Erie, Pennsylvania 16510 USA
P:+1 814.898.5000
FMC Technologies
Measurement Solutions, Inc. Germany Operation
500 North Sam Houston Parkway West, Smith Meter GmbH
www.fmctechnologies.com/measurementsolutions Suite 100 Regentstrasse 1
Houston, Texas 77067 USA 25474 Ellerbek, Germany
2014 FMC Technologies. All rights reserved. SS02001 Issue/Rev. 1.2 (7/14) P:+1 281.260.2190 P:+49 4101.304.0
6