POZZOLITH 101Ri

Set retarding and water reducing admixture

DESCRIPTION DOSAGE
POZZOLITH 101Ri is a non-chloride, extra-set retarding POZZOLITH 101Ri is used at the rate of range from 300
and water reducing admixture which allows the control of 500 ml per 100 kg cementitious. By trial mixture, find
setting times to be extended over a broad span of time the right dosage for the target setting time.
without the likelihood of extended, uncontrollable setting.
Setting time is controlled by varying the dose rate of DISPENSING
POZZOLITH 101Ri over a broad range of dose rates.
1. Introduce either undiluted solution or diluted solution
POZZOLITH 101Ri meets and exceeds JIS A6204 and of POZZOLITH 100Ri into the mixer at the mix.
ASTM C494 requirements for type B retarding and type 2. POZZOLITH 100Ri solution is part of mixing water.
D water-reducing and retarding admixtures. Adjust mixing water content.

POZZOLITH 100Ri does not contain intentionally added RATE OF HARDENING


calcium chloride or chloride based ingredients.
The temperature of the concrete mix and the ambient
RECOMMENDED FOR temperature (forms, earth, reinforcement, air, etc.) affect
the hardening rate of concrete. At higher temperature,
the area where cold-joint may appear concrete hardens more rapidly which may cause
continuous placement of mass concrete problems with placing and finishing.
hot weather concrete
use in all types of concrete where retardation of set One of the functions of POZZOLITH 101Ri admixtures is
and improved performance are desired to retard the set of concrete. Within the normal dosage
range, it will generally extend the compaction and setting
FEATURES AND BENEFITS time of concrete containing normal Portland cement
approximately 1 to 8 hours compared to a plain
control setting-time over a broad time span by concrete mix, depending on job materials and
varying the dose rate temperatures. Trial mixed should be made with job
water reduction and improved strength material, approximating job conditions to determine the
controls reaction of initial hydration between cement dosage required.
and water in fresh concrete and reduces hydration
heat development, and in the result of it, lowers POZZOLITH 101Ri admixture may be used at less than
highest temperature of fresh concrete recommended dosage for the purpose of retardation
improves water-tightness only.
improves durability
PACKAGING
COMPRESSIVE STRENGTH POZZOLITH 101Ri is supplied in bulk and in 205 litre
drums.
Concrete produced with POZZOLITH 101Ri admixture
will have rapid strength development after initial set CAUTIONS
occurs. If retardation is within the normal ASTM C 494
types B and D specifications, POZZOLITH 101Ri 1. If POZZOLITH 101Ri has frozen, thaw at 2C or
admixture will develop higher early (24 hours) and higher above completely reconstitute by mechanical
ultimate strengths than plain concrete when used within agitation. Do not use pressurized air for agitation.
the recommended dosage range and under normal, 2. Another admixture, rain water, etc. should not
comparable curing conditions penetrate in a container of POZZOLITH 101Ri during
storage
I Pozz101Ri/2/1201

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
POZZOLITH 101Ri

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.