Sub Head 1: EARTH WORK
1.1 Earth work in excavation by mechanical means (Hydraulic Excavator)/ cum
manual means in foundation trenches or drains (not exceeding 1.5 m
in width or 10 sqm on plan) including dressing of sides and ramming
of bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil

1.2 Earth work in excavation by mechanical means (Hydraulic excavator)/ cum


manual means over areas (exceeding 30cm in depth. 1.5m in width
as well as 10 sqm on plan) including disposal of excavated earth,
lead upto 50m and lift upto 1.5m, disposed earth to be levelled and
neatly dressed.
All kinds of soil

1.3 Extra for every additional lift of 1.5 m or part thereof in excavation / cum
banking excavated or stacked materials.
All kinds of soil
1.4 Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms,
depth upto 1.5 m including getting out the excavated soil, and then
returning the soil as required, in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering,
etc. and disposing of surplus excavated soil as directed, within a lead
of 50 m:

1.4.1 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm metre
dia.
1.4.2 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm metre

1.5 Clearing grass and removal of the rubbish upto a distance of 50 m 100 sqm
outside the periphery of the area cleared.
1.6 Filling available excavated earth (excluding rock) in trenches, plinth, cum
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.

gdmspl 1 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


1.7 Supplying and filling in plinth with Jamuna sand under floors, including cum
watering, ramming, consolidating and dressing complete.

1.8 Earth work in surface excavation not exceeding 30 cm in depth but 100 sqm
exceeding 1.5 m in width as well as 10 sqm on plan including disposal
of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be
levelled and neatly dressed :
All kinds of soil
1.9 Ploughing the existing ground to a depth of 15 cm to 25 cm and 100 sqm
watering the same.
All kinds of soil.
Total : Sub Head No. 1
Sub Head 2: CEMENT CONCRETE WORK
2.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centring and shuttering - All work upto plinth
level :
2.1.1 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm cum
nominal size)
2.1.2 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm cum
nominal size).
2.1.3 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm cum
nominal size)
2.1.4 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm Cum.
nominal size)
2.2 Providing and fixing up to floor five level precast cement concrete cum
string or lacing courses, copings, bed plates, anchor blocks, plain
window sills, shelves, louvers, steps, stair cases, etc., including
hoisting and setting in position with cement mortar 1:3 (1 Cement : 3
coarse sand), cost of required centering complete.
a) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20
mm nominal size)

2.3 Providing and mixing the Red, chocolate, orange, buff or yellow (red Kg.
oxide of iron) light shade/ dark shade pigment in precast cement
concrete pigment in mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3
graded stone aggregate 20 mm nominal size)

gdmspl 2 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


2.4 Providing and laying damp-proof course 40 mm thick with cement sqm
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
12.5 mm nominal size).
2.5 Extra for providing and mixing water proofing material in cement per 50 kg
concrete work in doses by weight of cement as per manufacturers cement
specification.

2.6 Applying a coat of residual petroleum bitumen of grade of VG-10 of sqm


approved quality using 1.7 kg per square metre on damp proof course
after cleaning the surface with brushes and finally with a piece of cloth
lightly soaked in kerosene oil.
2.7 Making plinth protection 50mm thick of cement concrete1:3:6 (1 sqm
cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal
size) over 75mm thick bed of dry brick ballast 40mm nominal size,
well rammed and consolidated and gouted with fine sand, including
finishing the to smooth.
Total : Sub Head No. 2
Sub Head 3: REINFORCED CEMENT CONCRETE WORK
3.1 Providing and laying in position machine batched and machine mixed
design mix M-25 grade cement concrete for reinforced cement
concrete work, using cement content as per approved design mix,
including pumping of concrete to site of laying but excluding the cost
of centering, shuttering, finishing and reinforcement, including
admixtures in recommended proportions as per IS: 9103 to
accelerate, retard setting of concrete, improve workability without
impairing strength and durability as per direction of Engineer-in-
charge. (Note :- Cement content considered in this item is @ 330
kg/cum. Excess/ less cement used as per design mix is
payable/recoverable separately).

3.1.1 All works upto plinth level cum


3.1.2 All works above plinth level upto floor V level. cum
3.2 Extra for providing richer mixes at all floor levels.
Note:- Excess/less cement over the specified cement content used
ispayable /recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC /RMC. cum
(Note:- Cement content considered in M-30 is @ 340 kg/kg/cum)

gdmspl 3 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


3.3 Add for using extra cement in the items of design mix over and above quintal
the specified cement content therein.
3.4 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four cum
floors or part thereof.
3.5 Steel reinforcement for R.C.C. work including straightening, cutting, kg
bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars grade FE 500 D as per IS1786

3.6 Steel reinforcement for R.C.C. work including straightening, cutting, kg


bending, placing in position and binding all complete above plinth
level.
Thermo-Mechanically Treated bars grade FE 500 D as per IS 1786
3.7 Centring and shuttering including strutting, propping etc. and removal
of form for :
3.7.1 Foundations, footings, bases of columns, etc. for mass concrete. sqm
3.7.2 Walls (any thickness) including attached pilasters, butteresses, plinth sqm
and string courses etc.
3.7.3 Suspended floors, roofs, landings, balconies and access platform sqm
3.7.4 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm
3.7.5 Columns, Pillars, Piers, Abutments, Posts and Struts sqm
3.7.6 Stairs, (excluding landings) except spiral-staircases sqm
3.7.7 Suspended floors, roofs, landings , balconies and access platform. sqm
with water proof ply 12 mm thick. (For exposed surface)
3.7.8 Lintels, beams, plinth beams, girders, bressumers, cantilevers & sqm
columns , walls . with water proof ply 12 mm thick. (For exposed
surface)
3.8 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse
sand: 4 graded stone aggregate 6 mm nominal size), reinforced with
1.6 mm dia mild steel wire, including centering and shuttering,
roughening cleaning, fixing and finishing in cement mortar 1:3 (1
cement: 3 fine sand) etc. complete, excluding plastering of the jambs,
sills and soffits.

3.8.1 a) 50 mm thick sqm


3.8.2 b) 75 mm thick sqm
3.9 Add for plaster drip course/ groove in plastered surface or moulding to meter
R.C.C. projections.

gdmspl 4 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


3.10 Makiing core cut in slab, beam, column for diiferent dia pipes by core
cutting machine and making good and water tight the space between
pipe and the structure with concrete. The annular space between the
pipe and the sleeves shall be sealed (upto a minimum depth 25 mm)
with fire resistant acrylic based sealent of approved make and quality.

3.10.1 a) 150 mm dia each


3.10.2 b) 100 mm dia each
Total : Sub Head No. 3
Sub Head 4: BRICK MASONRY WORK
4.1 Brick work with common burnt clay F.P.S. (non modular) bricks of cum
class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
4.2 Providing and laying autoclaved aereated cement blocks masonary cum
with 200/300 mm thick AAC block in superstructure above plinth level
up to floor V level in Cement mortar 1:6 (1 cement : 6 Coarse sand)

4.3 Brick work with non modular fly ash bricks conforming to IS:12894, cum
class designation 10 average compressive strength in super structure
above plinth level up to floor V level in :
Cement mortar 1:6 (1 cement : 6 Coarse sand)
4.4 Extra for brick work/AAC block masonry/ Tile brick masonry in cum
superstructure, above floor V level for every four floors or part thereof
by mechanical means
4.5 Half brick masonry with common burnt non modular bricks of class sqm
designation 7.5, in super structure above plinth and upto floor V level.
Cement mortar 1 : 4 (1 cement : 4 coarse sand)

4.6 Extra for half brick masonry in superstructure, above floor V level for sqm
every four floors or part thereof by mechanical means
4.7 Extra for providing and placing in position 2 nos 6mm dia M.S. bard at sqm
every third course of half brick masonry
4.8 Brick work with common burnt clay machine moulded modular bricks
of class designation 12.5 in exposed brick work including making
horizontal and vertical grooves 10 mm wide 12 mm deep complete in
cement mortar 1:6 (1 cement : 6 coarse sand).

gdmspl 5 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


4.8.1 From ground level upto plinth level cum
4.8.2 Above plinth level upto floor V level cum
4.9 Tile brick masonry work 5 cm thick with common burnt clay F.P.S. sqm
(non modular) tile bricks of class designation 10 in cement mortar 1:3
(1 cement : 3 coarse sand) in superstructure above plinth and upto
floor five level.
4.10 Providing and fixing partition upto ceiling height consisting of G.I. sqm
frame and required board, including providing and fixing of frame work
made of special section power pressed/ roll form G.I. sheet with zinc
coating of 120 gms/sqm(both side inclusive), consisting of floor and
ceiling channel 50mm wide having equal flanges of 32 mm and 0.50
mm thick, fixed to the floor and ceiling at the spacing of 610 mm
centre to centre with dash fastener of 12.5 mm dia meter 50 mm
length or suitable anchor fastener or metal screws with nylon plugs
and the studs 48 mm wide having one flange of 34 mm and other
flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor
and ceiling channel and placed at a spacing of 610 mm centre to
centre by 6 mm dia bolts and nuts, including fixing of studs along both
ends of partition fixed flush to wall with suitable anchor fastener or
metal screws with nylon plugs at spacing of 450 mm centre to centre,
and fixing of boards to both side of frame work by 25 mm long dry wall
screws on studs, floor and ceiling channels at the spacing of 300 mm
centre to centre. The boards are to be fixed to the frame work with
joints staggered to avoid through cracks, M.S. fixing channel of 99
mm width (0.9 mm thick having two flanges of 9.5 mm each) to be
provided at the horizontal joints of two boards, fixed to the studs using
metal to metal flat head screws, including jointing and finishing to a
flush finish with recommended jointing compound, jointing tape, angle
beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two
coats of primer suitable for board as per manufactures specification
and direction of engineer in charge all complete.
75mm overall thickness partition with 12.5 mm thick double skin
tapered edged plain Gypsum board conforming to IS: 2095: part I

Total : Sub Head No. 4

gdmspl 6 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Sub Head 5 : Stone Work
5.1 Random rubble masonry with hard stone in foundation and plinth cum
including levelling up with cement concrete 1:6:12 (1cement : 6
coarse sand : 12graded stone aggregate 20 mm nominal size) upto
plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)

5.2 Coursed rubble masonry with hard stone (first or second sort) in cum
superstructure above plinth level and upto floor five level.
Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse
sand)
Total : Sub Head No. 5
Sub Head 6: Steel Work
6.1 Steel work in built up tubular ( round, square or rectangular hollow kg
tubes etc.) for frame work, gate, trusses etc., including cutting,
hoisting, fixing in position and applying a priming coat of approved
steel primer, including welding and bolted with special shaped
washers etc. complete
a) Electric resistance or induction butt welded tubes.
b) Primer will be low VOC content less than 250 grams / Litre

6.2 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved
steel primer using structural steel etc. as required.
6.2.1 In gratings, frames, guard bar, ladder, railings, brackets, gates and kg
similar works kg 90.10
6.3 Supplying and fixing rolling shutters of approved make, made of
required size M.S. laths, interlocked together through their entire
length and jointed together at the end by end locks, mounted on
specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull
operation complete, including the cost of providing and fixing
necessary 27.5 cm long wire springs manufactured from high tensile
steel wire of adequate strength conforming to IS: 4454 - part 1 and
M.S. top cover of required thickness for rolling shutters

6.3.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover sqm sqm

gdmspl 7 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


6.4 Extra for providing grilled rolling shutters manufactured out of 8 mm sqm
dia M.S. bar instead of laths as per design approved by Engineer-in-
charge, (area of grill to be measured).
6.5 Providing and fixing Grab bar supports etc for disable friendly toilets
using brush #8 finished Stainless steel members ( Stainless Steel
Grade 316 ) including hold fasts, cutting, drilling, hoisting, fixing and
argon welding etc. in position as per approved drawing and direction
of Engineer in charge. ( work shall be executed through deptt.
approved specialised agency only )

6.5.1 a) wash basin Grab bar (2.5kgs) as per drawings each


6.5.2 b) W.C. back rest (3.5kgs) as per drawings each
6.5.3 c) L-Shape Grab bar (3.5kgs) as per drawings each
6.5.4 d) Swing-Up Grab bar (4.7kgs) as per drawings each
Total : Sub Head No. 6
Sub Head 7:Wood Work
7.1 Providing wood work in frames of doors, windows, clerestory windows cum
and other frames, wrought framed and fixed in position with hold fast
lugs or with dash fasteners of required dia & length (hold fast lugs or
dash fastener shall be paid for separately).
Kiln seasoned and chemically treated Sal wood
7.2 Providing and fixing panelled or panelled and glazed shutters for
doors, windows and clerestory windows, including ISI marked M.S.
pressed butt hinges bright finished of required size with necessary
screws, excluding panelling which will be paid for separately, all
complete as per direction of Engineer-in-charge.
7.2.1 Second class teak wood sqm
35 mm thick shutters
7.3 Providing and fixing panelling or panelling and glazing in panelled or
panelled and glazed shutters for doors, windows and clerestory
windows (Area of opening for panel inserts excluding portion inside
grooves or rebates to be measured). Panelling for panelled or
panelled and glazed shutters 25 mm to 40 mm thick:
7.3.1 Decorative plywood both side decorative veneer (Type - I) sqm
conforming to IS 1328 BWR type

gdmspl 8 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


7.4 Extra for providing ISI marked Stainless Steel butt hinges instead of sqm
M.S. pressed butt hinges bright finished of required size with
necessary screws. (Shutter area to be measured).
7.5 Providing and fixing ISI marked flush door shutters conforming to IS : sqm
2202 (Part I) non-decorative type, core of block board construction
with frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on
both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with
necessary screws

7.6 Extra for Providing and fixing flush doors with decorative veneering sqm
instead of non decorative ISI marked flush door shutters conforming
to IS: 2202 (Part I) on one side only
7.7 Extra for providing lipping with 2nd class teak wood battens 25 mm sqm
minimum depth on all edges of flush door shutters (over all area of
door shutter to be measured).
7.8 Providing and fixing expandable fasteners of specified size with Each
necessary plastic sleeves and galvanised M.S. screws including
drilling holes in masonry work /CC/ R.C.C. and making good etc.
complete.
50 mm long
7.90 Providing and fixing curtain rods of 1.25 mm thick chromium plated Meter
brass plate, with two chromium plated brass brackets fixed with C.P.
brass screws and wooden plugs, etc., wherever necessary complete :
20 mm dia

7.10 Providing and fixing aluminium sliding door bolts, ISI marked
anodised anodic coating not less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or shade, with nuts and screws
etc. complete :
7.10.1 300x16 mm Each
7.11 Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or shade, with necessary
screws etc. complete :
7.11.1 300x10 mm Each

gdmspl 9 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


7.11.2 200x10 mm Each
7.11.3 150x10 mm Each
7.11.4 100x10 mm Each
7.12 Providing and fixing aluminium handles, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868) transparent or
dyed to required colour or shade, with necessary screws etc.
complete :
7.12.1 125 mm Each
7.12.2 100 mm Each
7.12.3 75 mm Each
7.13 Providing and fixing aluminium hanging floor door stopper, ISI Each
marked, anodised (anodic coating not less than grade AC 10 as per
IS : 1868) transparent or dyed to required colour and shade, with
necessary screws etc. complete.
a) Twin rubber stopper
7.14 Providing & Fixing decorative high pressure laminated sheet of plain / sqm
wood grain in gloss / matt / suede finish with high density protective
surface layer and reverse side of adhesive bonding quality conforming
to IS : 2046 Type S, including cost of adhesive of approved quality.
a) 1.0 mm thick.

7.15 Providing wood work in frames of false ceiling, partitions etc. sawn cum
and fixed in position :
a) Sal wood

gdmspl 10 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


7.16 Supply and install modular toilet cubicles of MERINO-BESCO make each
'TITAN STD' series or equivallent as per manufaturer's std
specifications.All intermediate panels, pilasters, doors shall be made
up of Solid Compact Laminate (Phenolic Core Board) as per IS 2046
based on thermosetting resins, homogeneously reinforced with
cellulose fibers making cubicles impervious to Water, resistant to Fire,
etc. Compact laminate should be Greenguard and IGBC certified, All
accessories shall be SS 304 grade including all hardware/fittings. The
pilaster are anchored to the flooring using adjustable SS legs.The SS
SQUARE top rail shall be fixed on the top of the pilasters. Std
accessories include SS Hinges, SS Door knob, SS thumb turn
indicator, SS coat hook, SS SQUARE top rail and SS channels (All
accessories in SS 304 grade) SS legs in SS 316 Grade.Titan Std
Series Cubicles: Std Sizes (W x D x H)- 900 mm x 1550 mm x 21000
mm, ( Height is including 150 mm gap from bottom) Door Size- 600
mm

7.17 Providing and fixing SS finish pure 8100 Type 2 Package with Pair of each
Pure 8100 Design Lever Handle on Roses & escutcheons. Including
271a Sash lock with 72mm CTC, 55mm Backset 20mm Square
forend. EPC 60mm length one side key other side thumb turn
operation all complete , Make -DORMA or equivallent
7.18 Providing and fixing SS Finish 100 mm Mortise Keyless Latch ISI each
marked100mm SS finish handles of approved
quality with necessary screws etc. complete.Make- Godrej , Model no:
9155-LKYLDMKL1
7.19 Providing and fixing SS Finish CYLINDRICAL LOCKS - Keyless each
(Toilet) Latch ISI marked100mm SS finish handles of
approvedquality with necessary screws etc. complete.Make- Godrej ,
Model no: 9843-LKYPDC547
7.20 Providing and fixing aluminium extruded section body tubular type each
universal hydraulic door closer (having brand logo with ISI, IS : 3564,
embossed on the body, door weight upto 36 kg to 80 kg and door
width from 701 mm to1000 mm), with double speed adjustment with
necessary accessories and screws etc. complete.

gdmspl 11 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


7.21 Providing and fixing SS Finish 200 mm Pull handle of each
approvedquality with necessary screws etc. complete.Make- Godrej ,
Model no: 7557-LKYPDMN37 or equivallent
Total : Sub Head No. 7
Sub Head No. 8 :Flooring
8.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded sqm
stone aggregate) finished with a floating coat of neat cement,
including cement slurry, but excluding the cost of nosing of steps etc.
complete.
40 mm thick with 20 mm nominal size stone aggregate
8.2 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 sqm
cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick.

8.3 Kota stone slab flooring over 20 mm (average) thick base laid over sqm
and jointed with grey cement slurry mixed with pigment to match the
shade of the slab, including rubbing and polishing complete with base
of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
8.4 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and sqm
pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3
coarse sand) and jointed with grey cement slurry mixed with pigment
to match the shade of the slabs, including rubbing and polishing
complete.
8.5 Shot blasted Kota stone slab flooring over 20 mm (average) thick sqm
base laid over and jointed with grey cement slurry mixed with pigment
to match the shade of the slab, complete with base of cement mortar
1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
8.6 Extra for Prefinished nosing in treads of steps of Kota Stone / Metre
sandstone slab
8.7 Extra for Kota stone / sand stone in treads of steps and risers using sq. m.
single length upto 1.05 m

gdmspl 12 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


8.8 Providing and laying vitrified floor tiles in different sizes (thickness to sqm
be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS : 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4
coarse sand), including grouting the joints with white cement and
matching pigments etc., complete.
Size of Tile 600x600 mm

8.9 Providing and laying Vitrified tiles in different sizes (thickness to be


specified by manufacturer), with water absorption less than 0.08 %
and conforming to I.S. 15622, of approved make, in all colours &
shade, in skirting, riser of steps, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with
white cement & matching pigments etc. complete.

8.9.1 Size of Tile 500x500 mm sqm


8.9.2 Size of Tile 600x600 mm sqm
8.10 Providing and fixing Ist quality ceramic glazed wall tiles conforming to sqm
IS: 15622 (thickness to be specified by the manufacturer), of
approved make, in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick bed of cement mortar 1:3
(1 cement : 3 coarse sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white cement mixed with pigment
of matching shade complete.

8.11 Stone tile (polished) work for wall lining over 12 mm thick bed of sqm
cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @
3.3 kg/sqm including pointing in white cement complete
Granite of any colour and shade

gdmspl 13 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


8.12 Providing and laying flamed finish Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of the
building all complete as per the architectural drawings with 18 mm
thick stone slab over 20 mm (average) thick base of cement mortar
1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and
pointing with white cement slurry admixed with pigment of matching
shade including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge :

8.12.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, sqm
Cat Eye or equivalent.
8.13 Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms,
vanity counters, window sills , facias and similar locations of required
size, approved shade, colour and texture laid over 20 mm thick base
cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch ups,
including rubbing, curing, moulding and polishing to edges to give
high gloss finish etc. complete at all levels.

8.13.1 Granite of any colour and shade sqm


Area of slab over 0.50 sqm
8.14 Chequerred precast cement concrete tiles 22 mm thick in footpath & sqm
courtyard, jointed with neat cement slurry mixed with pigment to
match the shade of tiles, including rubbing and cleaning etc.
complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4
coarse sand). Light shade pigment using white cement
Medium shade pigment using 50% white cement 50% Grey cement

8.15 40 mm thick rubbed stone flooring over 20 mm (average) thick base sqm
of cement mortar 1:5 (1 cement :5 coarse sand) with joints 3 mm
thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust)
admixed with pigment to match the shade of stone and pointing with
same mortar. a)White sand stone

gdmspl 14 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


8.16 Providing and laying tactile tile (for vision impaired persons as per sqm
standards) of size 300x300x9.8mm having with water absorption less
than 0.5% and conforming to IS: 15622 of approved make in all
colours and shades in for outdoor floors such as footpath, court yard,
multi modals location etc., laid
on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand)
in all shapes & patterns including grouting the joints with white cement
mixed with matching pigments etc. complete as per direction of
Engineer-in-Charge.

8.17 Providing and fixing Glass mossaic tiles at finished plain wall surface sqm
of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in
customize design as per direction of Engineer-in- Charge. The glass
mosaic tiles to be fixed on the wall surface with the help of approved
adhesive applied at the rate of 2.5 kg per sqm and grouting of the
same. The rate is inclusive of all operation, material and required
pattern approved by Engineer-in-Charge:

8.18 Rough Kota stone slab flooring over 20 mm (average) thick base laid sqm
over and jointed with grey cement slurry mixed with pigment to match
the shade of the slab, including cleaning all complete with base of
cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
8.19 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of sqm
approved make and colour using acid and/or alkali resisting mortar
bedding, and joints filled with acid and/or alkali resisting cement as
per IS: 4457, complete as per the direction of Engineer-in- Charge In
flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4
coarse sand)
Acid and alkali resistant tile

8.2 Providing and fixing stone slab with table rubbed, edges rounded and sqm
polished, of size 75x50 cm deep and 3.0cm thick, fixed in urinal
partitions by cutting a chase of appropriate width with chase cutter
and embedding the stone in the chase with epoxy grout or with
cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone
aggregate 6 mm nominal size) as per direction of Engineer-in-charge
and finished smooth.
Granite Stone of approved shade

gdmspl 15 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


8.21 Extra for making groove on stone work steps tread to make it anti-skid metre
, size of groove 8mm wide 3mm deep all complete as per direction of
Engineer -in-charge (stone work shall be paid seperatly)

Total : Sub Head No. 8


Sub Head No. 9 :Roofing
9.1 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 metre
coarse sand : 4 stone aggregate 10 mm and down gauge), including
finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per
standard design in 75x75 mm deep chase
9.2 Making khurras 45x45 cm with average minimum thickness of 5 cm each
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400
micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse
sand) and a coat of neat cement, rounding the edges and making and
finishing the outlet complete.

9.3 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm sqm
x20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70
and initial emittance > 0.75 on waterproof and sloped surface of
terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1
cement : 4 coarse sand) and grouting the joints with mix of white
cement & marble powder in ratio of 1:1, including rubbing and
polishing of the surface upto 3 cuts complete, including providing
skirting upto 150 mm height along the parapet walls in the same
manner.

9.4 Providing and laying roof insulation with 40 mm thick impervious sqm
sprayed,closed cell free Rigid Polyurethane foam over deck insulation
conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum),
over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying
400 G polythene
sheet over PUF spray and providing a wearing course of 40 mm thick
cement screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate
20 mm nominal size) in chequered rough finish, in panels of 2.5 m x
2.5 m and embedding with 24 G wire netting and sealing the joints
with polymerized mastic, all complete as per direction of Engineer-in-
Charge.

gdmspl 16 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


9.5 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm
sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm,
including cleaning the slab surface with brushes and finally with a
piece of cloth lightly soaked in kerosene oil complete :
With residual type petroleum bitumen of grade VG - 10 .

9.6 Providing and fixing tiled false ceiling of approved materials of size sqm
595x595 mm in true horizontal level, suspended on inter locking metal
grid of hot dipped galvanized steel sections ( galvanized @ 120
grams/ sqm, both side inclusive) consisting of main T runner with
suitably spaced joints to get required length and of size 24x38 mm
made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm
center to center and cross T of size 24x25 mm made of 0.30 mm
thick (minimum) sheet, 1200 mm long spaced between main T at
600 mm center to center to form a grid of 1200x600 mm and
secondary cross T of length 600 mm and size 24x25 mm made of
0.30 mm thick (minimum) sheet to be interlocked at middle of the
1200x600 mm panel to form grids of 600x600 mm and wall angle of
size 24x24x0.3 mm and laying false ceiling tiles of approved texture in
thegrid including, required cutting/making, opening for services like
diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T
runners to be suspended from ceiling using GI slotted cleats of size
27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm
long dash fasteners, 4mm GI adjustable rods with galvanised butterfly
level clips of size 85 x 30x 0.8 mm spaced at 1200 mm center to
center along main T, bottom exposed width of 24 mm of all T-sections
shall be pre-painted with polyesterpaint, all complete for all heights as
per specifications, drawings and as directed by Engineer-in-charge.GI
Metal Ceiling Lay in plain Tegular edge Global white color tiles of size
595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet
having galvanizing of 100 gms/sqm (both sides inclusive) and electro
statically polyester powder coated of thickness 60 microns (minimum),
including factory painted after bending.

Total : Sub Head No. 9

gdmspl 17 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Sub Head No. 10 :Finishing
10.1 12 mm cement plaster of mix : sqm
1:6 (1 cement : 6 coarse sand)
10.2 15 mm cement plaster on rough side of single or half brick wall of mix sqm
1:6 (1 cement : 6 coarse sand)

10.3 6 mm cement plaster of mix sqm


1:3 (1 cement : 3 fine sand)
10.4 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating sqm
coat of neat cement.
20 mm cement plaster
10.5 Providing and applying plaster of paris putty of 2 mm thickness over sqm
plastered surface to prepare the surface even and smooth complete.

10.6 Wall painting with acrylic emulsion paint, having VOC (Volatile sqm
Organic Compound ) content less than 50 grams/ litre, of approved
brand and manufacture, including applying additional coats wherever
required, to achieve even shade and colour (Exterior Grade)
Two coats

10.7 Wall painting with premium acrylic emulsion paint of the interior grade, sqm
having VOC (Volatile Organic Compound) content less than 50
grams/litre of approved brand and manufacture, including applying
additional coats whereever required to achieve even shade and
colour. (Interior Grade)
Two or more coats on new work

10.8 Finishing with Deluxe Multi surface paint system for interiors and sqm
exteriors using Primer as per manufacturers specifications:
Painting wood work with Deluxe Multi Surface Paint of
requiredbshade. Two or more coat applied @ 0.90 ltr/10 sqm over
annunder coat of primer applied @0.75 ltr/ 10 sqm of approved brand
and manufacture.

10.9 French spirit polishing : sqm


Two or more coats on new works including a coat of wood filler.

gdmspl 18 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


10.10 Painting with synthetic enamel paint, having VOC (Volatile Organic sqm
Compound) content less than 150 grams/ litre, of approved brand and
manufacture, including applying additional coats wherever required to
achieve even shade and colour.
Two coats
10.11 Finishing walls with textured exterior paint of required shade : New sqm
work (Two or more coats applied @ 3.28 ltr/10 sqm) over and
including priming coat of exterior primer applied @ 2.20kg/10 sqm
10.12 Distempering with 1st quality acrylic distemper, having VOC (Volatile sqm
Organic Compound ) content less than 50 grams/ litre, of approved
brand and manufacture, including applying additional coats wherever
required,
to achieve even shade and colour.
a) Two coats

Total : Sub Head No. 10


Sub Head No. 11 :ALUMINIUM WORK
11.1 Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular sections/
appropriate Z sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with dash fasteners of
required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass
/ stainless steel screws, all complete as per architectural drawings
and the directions of Engineer-in-charge. (Glazing, paneling and dash
fasteners to be paid for separately.

11.1.1 For fixed portion Kilogram


Powder coated aluminium (minimum thickness of powder coating 50
micron)

gdmspl 19 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


11.1.2 For shutters of doors, windows & ventilators including providing and Kilogram
fixing hinges/ pivots and making provision for fixing of fittings
wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50
micron) kg 435.75

11.2 Providing and fixing glazing in aluminium door, window, ventilator


shutters and partitions etc. with EPDM rubber / neoprene gasket etc.
complete as per the architectural drawings and the directions of
engineer-in-charge.
(Cost of aluminium snap beading shall be paid in basic item)
11.2.1 With float glass panes of 4.0 mm thickness sqm
11.2.2 With float glass panes of 5.50 mm thickness sqm
11.3 Providing and fixing 100mm brass locks (best make of approved Each
quality) for aluminium doors including necessary cutting and making
good etc. complete.
11.4 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Meter
Stone work by providing weather silicon sealant over backer rod of
approved quality as per architectural drawings and direction of
Engineer-in-charge complete.
a) Upto 5mm depth and 5 mm width.
11.5 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire Sqm
and 1.4 mm wide aperture with
matching wood beading
Total : Sub Head No. 11
Sub Head 12 : WATER PROOFING TREATMENT WORK

gdmspl 20 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


12.1 Providing and laying water proofing treatment to vertical and sqm
horizontal surfaces of depressed portions of W.C., kitchen and the like
consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with
water proofing compound conforming to IS 2645 in recommended
proportions including rounding off junction of vertical and horizontal
surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse
sand) mixed with water proofing compound in recommended
proportion including rounding off junction of vertical and horizontal
surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at
1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of
PVC sheet should be 100 mm wide and pasted to each other with
bitumen @ 1.7 kg/sqm).

gdmspl 21 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


12.2 Providing and laying integral cement based water proofing treatment sqm
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: a) Applying
a slurry coat of neat cement using 2.75 kg/sqm of cement admixed
with water proofing compound conforming to IS. 2645 and approved
by Engineer-in-charge over the RCC slab including adjoining walls
upto 300 mm height including cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of
cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with
water proofing compound conforming to IS : 2645 and approved by
Engineer-in-charge to required slope and treating similarly the
adjoining walls upto 300 mm height including rounding of junctions of
walls and slabs c) After two days of proper curing applying a second
coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless
cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with
water proofing compound conforming to IS : 2645 and approved by
Engineer-in-charge including laying glass fibre cloth of approved
quality in top layer of plaster and finally finishing the surface with
trowel with neat cement slurry and making pattern of 300x300 mm
square 3 mm deep. e) The whole terrace so finished shall be flooded
with water for a minimum period of two weeks for curing and for final
test. All above operations to be done in order and as directed and
specified by the Engineer -in- Charge :
a) With average thickness of 120 mm and minimum thickness at
khurra as 65 mm.

12.3 Grading roof for water proofing treatment with Cement concrete 1:2:4 cum
(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size).
Total : Sub Head No. 12
Sub Head 13 : ROAD WORKS/ EXTERNAL DEVELOPMENTAL
WORKS

gdmspl 22 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


13.1 Preparation and consolidation of sub grade with power road roller of 8 sqm
to 12 tonne capacity after excavating earth to an average of 22.5 cm.
depth, dressing to camber and consolidating with road roller including
making good the undulations etc. and re-rolling the sub grade and
disposal of surplus earth lead upto 50 metres.
13.2 Extra for compaction of earth work in embankment under optimum cum
moisture conditions to give at least 95% of the maximum dry density
(proctor density).
13.3 Construction of granular sub-base by providing close graded Material
conforming to specifications, mixing in a mechanical mix plant at
OMC, carriage of mixed material by tippers to work site, for all leads &
lifts, spreading in uniform layers of specified thickness with motor
grader on prepared surface and compacting with vibratory power
roller to achieve the desired density, complete as per specifications
and directions of Engineer-in-Charge.

13.3.1 a) With material conforming to Grade-I (size range 75 mm to 0.075 cum


mm) having CBR Value-30
13.3.2 b) With material conforming to Grade-II (size range 53 mm to 0.075 cum
mm ) having CBR Value-25
13.3.3 c) With material conforming to Grade-III (size range 26.5 mm to 0.075 cum
mm ) having CBR Value-20
13.4 Construction of dry lean cement concrete sub base over a prepared cum
sub-grade with coarse and fine aggregate conforming to IS:383, the
size of coarse aggregate not exceeding 25 mm, aggregate cement
ratio not to exceed 15:1, aggregate gradation after blending to be as
per specifications, cement content not to be less than 150 Kg/cum,
optimum moisture content to be determined during trial length
construction, concrete strength not to be less than 10 Mpa at 7 days,
mixed in a batching plant, transported to site, for all leads & lifts, laid
with a mechanical paver, compacting with 8-10 tonne vibratory roller,
finishing and curing etc. complete as per direction of Engineer-
incharge.

gdmspl 23 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


13.5 Providing and applying tack coat using hot straight run bitumen of sqm
grade VG - 10, including heating the bitumen, spraying the bitumen
with mechanically operated spray unit fitted on bitumen boiler,
cleaning and preparing the existing road surface as per
specifications :
On bituminous surface @ 0.50 Kg / sum.

13.6 Providing and laying Dense Graded Bituminous Macadam using CUM
crushed stone aggregates of specified grading, premixed with
bituminous binder and filler, transporting the hot mix to work site by
tippers, laying with paver finisher equiped with electronic sensor to the
required grade, level and alignment and rolling with smooth wheeled,
vibratory and tandem rollers as per specifications to achieve the
desired compaction and density, complete as per specificatons and
directions of Engineer-in-Charge.
50 to 100 mm average compacted thickness with bitumen of grade
VG-30 @5% (percentage by weight of total mix) and lime filler @ 2%
(percentage by weight of Aggregate) prepared in Batch Type Hot Mix
Plant of 100-120 TPH capacity.

13.7 Providing and laying Bituminous concrete using crushed stone cum
aggregates of specified grading, premixed with bituminous binder and
filler, transporting the hot mix to work site by tippers, laying with paver
finisher equiped with electronic sensor to the required grade, level
and alignment and rolling with smooth wheeled, vibratory and tandem
rollers to achieve the desired compaction and density as per
specification, complete and as per directions of Engineer-in-Charge.
40/50 mm compacted thickness with bitumen of grade VG-30 @5.5%
(percentage by weight of total mix) and lime filler @ 3% (percentage
by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-
120 TPH capacity.

gdmspl 24 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


13.8 Providing and laying C.C. pavement of mix M-25 with ready mixed cum
concrete from batching plant. The ready mixed concrete shall be laid
and finished with screed board vibrator , vacuum dewatering process
and finally finished by floating, brooming with wire brush etc. complete
as per specifications and directions of Engineer-incharge. (The panel
shuttering work shall be paid for separately).

13.9 Centring and shuttering including strutting, propping etc. and removal sqm
of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
13.10 Providing and applying 2.5mm thick road marking strips (retro- sqm
reflective) of specified shade/ colour using hot thermoplastic material
by fully/ semi automatic thermoplastic paint applicator machine fitted
with profile shoe, glass beads dispenser, propane tank heater and
profile shoe heater, driven by experienced operator on road surface
including cost of material, labour ,T&P, cleaning the road surface of all
dirt, seals, oil, grease and foreign material etc. complete as per
direction of Engineer-in-charge and accordance with applicable
specifications.(cost of Staincile shall be shall be paid seperatly)

13.11 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and sqm
chisel dressed on top, for paving in floors, drains etc. laid over 20mm
thick base mortar 1:4 (1cement:4 coarse sand) with joints 10mm wide
filled with same mortar including ruled pointing etc. complete as per
direction of engineer-in charge
13.12 Providing and laying at or near ground level factory made kerb stone Cum
i/c kerb cut, round curve etc. of M-25 grade cement concrete in
position to the required line, level and curvature, jointed with cement
mortar 1:3 (1 cement: 3 coarse sand), including making joints with or
without grooves (thickness of joints except at sharp curve shall not to
more than 5mm), including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge (length
of finished kerb edging shall be measured for payment). (Precast C.C.
kerb stone shall be approved by Engineer-in-charge).

gdmspl 25 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


13.13 Providing and fixing at or near ground level factory made kerb sqm
channel of size 250x450x50mm RCC slab of M-30 grade , including
reinforcement with 6 mm dia M.S. bars 2 nos & 4nos on each side,
including setting in position in footpath to the required level and line
over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5
coarse sand), having joint thickness not more than 5mm except on
curve, including filling of joints with same cement mortar and making
grooves etc. complete as per direction of Engineer-in-charge.

13.14 Providing and laying 60mm thick factory made cement concrete sqm
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size, design &
shape, laid in required colour and pattern over and including 50mm
thick compacted bed of coarse sand, filling the joints with fine sand
etc. all complete as per the direction of Engineer-in-charge.

13.15 40 mm thick fine dressed stone flooring over 20 mm (average) thick sqm
base of cement mortar 1:5 (1 cement : 5 coarse sand), including
pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an
admixture of pigment to match the shade of stone.
A) White sand stone
13.16 Tile brick Brick on edge flooring with with common burnt clay sqm
machine moulded F.P.S. (non modular) bricks of class designation
12.5 conforming to IS : 2690 (Part I) of size 230x115x50 mm laid on
20mm thick bed (average) 1:6 (1 cement : 6 coarse sand) & joints
filled with 1:6 (1 cement : 6 coarse sand) all complete in approved
pattern and direction of Engineer in Charge.

13.17 7.50cm thick Brick flooring with common burnt clay machine moulded sqm
F.P.S. (non modular) of class designation 12.5 of size 230x115x75mm
thick including cement slurry etc. over 20mm (average) thick base in
cement mortar 1:4 (1 cement : 4 coarse sand ) and joints filled with
1:4 (1 cement : 4 coarse sand) all complete in approved pattern and
direction of Engineer in Charge.

13.18 Supplying and stacking at site & filling the same in pit. cum
Moorum

gdmspl 26 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


13.19 Supplying & stacking of graded stone aggregate at site of size range.

13.19.1 90mm to 45 mm cum


13.19.2 63mm to 45 mm cum
13.19.3 53mm to 22.4 mm cum
13.19.4 d) stone screening 13.2mm nominal size ( Type A ) cum
13.19.5 e) stone screening 11.2mm nominal size ( Type B ) cum
13.19.6 f) red bajari at site cum
13.20 Laying, spreading and compacting stone aggregate of specified sizes cum
to WBM specifications in uniform thickness, hand picking, rolling with
3 wheeled road / vibratory roller 8-10 tonne capacity in stages to
proper grade and camber, applying and brooming requisite type of
screening / binding material to fill up interstices of coarse aggregate,
watering and compacting to the required density .

Total : Sub Head No. 13


Sub Head 14 : SANITARY FIXTURES AND TOILET REQUISITES

14.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as Each
per IS 13983 with C.I. brackets and stainless steel plug 40 mm
including painting of fittings and brackets, cutting and making good
the walls wherever required :
Kitchen sink with drain board
510x1040 mm bowl depth 200mm.

14.2 Providing and fixing 32 mm C.P. cast brass bottle trap with unions, Each
complete including cutting and making good the walls and floors, all
complete
Make : Jaquar
14.3 Providing and fixing of 15 mm dia brass angle valve (inlet fitting ball Each
valve type) having strainer screen complete with wall flange of
following make and model:(or equal approved)
Make : ARCO, Spain
Colour/Finish : Chrome

gdmspl 27 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


14.4 Providing and fixing of 15 mm dia, 450 mm long flexible connection Each
pipe having EPDM rubber internal core and stainless steel braided
outer sheath complete with C.P brass end nuts, of approved make.

14.5 Providing and fixing C.P brass ablution faucet (health faucet) Each
comprising hand held shower with operating lever, 1 m long flexible
tube and wall hook all complete.
NOTE: Faucet shall meet Green Building/ GRIHA certification
requirement for flow.
Make : JAQUAR
Model : Continental
Cat. No. : 573 GA
Colour/Finish : Chrome

14.6 Providing and fixing vitreous china wash basin and special C.I Each
brackets, including C.P. brass waste of standard pattern, complete
including cutting and making good the walls and floors, wherever
required of the following make and type: (or equal approved)
Make : Hindware
Model : NEO
Cat. No. : 10098
Colour : White

14.7 Providing and fixing white vitreous china battery based infrared Each
sensor operated urinal of approx. size 610 x 390 x 370 mm having
pre & post flushing with water (250 ml & 500 ml consumption), having
water inlet from back side, including fixing to wall with suitable
brackets all as per manufacturers specification and direction of
Engineer-in-charge.

14.8 Providing and fixing of spring loaded self closing type 15 mm dia C.P Each
brass pillar cock with wall flange,of following make. (or equal
approved).
NOTE: Pillar Cock shall meet Green Building/ GRIHA certification
requirement for flow.
Make : Jaquar
Model : PRS-031GA

gdmspl 28 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


14.9 Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete.
14.9.1 Flexible pipe Each
40 mm dia
14.10 Providing and fixing white vitreous china pedestal type water closet Each
(European type W.C. pan) with seat and lid, with all fittings and
fixtures complete, including cutting and making good the walls and
floors wherever required :
14.11 Providing, fixing and commissioning remotely operated pneumatic Each
dual flush WC Flushing Cistern with Flushing Actuator Plate (of
approved finish), cutting and making good the walls including making
connection with WC Pan, all as per the Manufacturer`s specifications,
of the following make and type:(or equal approved)
Make : COMMANDER

14.12 Providing and fixing vitreous china large flat back Urinal Basin of size Each
580 mm x 380 mm x 350 mm deep, 32 mm dia C.P. brass domical
waste, complete, cast iron hangers for support, including cutting and
making good the walls wherever required, of the following make and
type (or equal approved)
14.13 Providing and fixing C.P. brass long body bib cock of approved quality Each
conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore

Total : Sub Head No. 14


Sub Head 15 : SOIL, WASTE & VENT AND RAIN WATER
PIPEWORK
15.1 Providing and fixing soil, waste and vent pipes :
15.1.1 100 mm dia. Centrifugally cast (spun) iron socket & spigot (S&S) pipe Metre
as per IS: 3989.
15.1.2 75 mm dia. Centrifugally cast (spun) iron socket & spigot (S&S) pipe Metre
as per IS: 3989.
15.2 Providing and fixing M.S. holder-bat clamps of approved design to
Sand Cast iron/cast iron (spun) pipe embedded in and including
cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size)
including cost of cutting holes and making good the walls etc. :

gdmspl 29 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


15.2.1 for 100 mm dia pipe Each
15.2.2 for 75 mm dia pipe Each
15.3 Providing and fixing bend of required degree with access door,
insertion rubber washer 3 mm thick, bolts and nuts complete
15.3.1 100 mm dia. Sand cast iron S&S as per IS - 3989 Each
15.4 Providing and fixing plain bend of required degree.
15.4.1 100 mm dia. Sand cast iron S&S as per IS : 3989 Each
15.4.2 75 mm dia. Sand cast iron S&S as per IS : 3989 Each
15.5 Providing and fixing single equal plain junction of required degree with Each
access door, insertion rubber washer 3 mm thick, bolts and nuts
complete.
100 x 100 x 100 mm Sand cast iron S&S as per IS - 3989
15.6 Providing and fixing single equal plain junction of required degree Each
100 x 100 x 100 mm Sand cast iron S&S as per IS - 3989
15.7 Providing and fixing double equal plain invert branch of required Each
degree:
100x100x100x100 mm Sand cast iron S&S as per IS - 3989
15.8 Providing and fixing single equal plain invert branch of required
degree:
15.8.1 100x100x100 mm Sand cast iron S&S as per IS - 3989 Each
15.8.2 75x75x75 mm Sand cast iron S&S as per IS - 3989 Each
15.9 Providing and fixing terminal guard
15.9.1 100 mm Sand cast iron S&S as per IS - 3989 Each
15.9.2 75 mm Sand cast iron S&S as per IS - 3989 Each
15.10 Providing lead caulked joints to sand cast iron / centrifugally cast
(spun) iron pipes and fittings of diameter.
15.10.1 100 mm Each
15.10.2 75 mm Each
15.11 Providing and fixing M.S. stays and clamps for sand cast iron /
centrifugally cast (spun) iron pipes of diameter.
15.11.1 100 mm Each
15.11.2 75 mm Each

gdmspl 30 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


15.12 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent
pipes and fittings with two coats of synthetic enamel paint of any
colour such as chocolate grey, or buff etc. over a coat of primer (of
approved quality) for new work :
15.12.1 100 mm diameter pipe Metre
15.12.2 75 mm diameter pipe Metre
15.13 Providing and fixing G.I. pipes complete with G.I. fittings including
trenching and refilling etc.
External work
For Waste line in toilets and Kitchen
15.13.1 32 mm dia. nominal bore Metre
15.13.2 40 mm dia. nominal bore Metre
15.13.3 50 mm dia. nominal bore Metre
15.14 Painting G.I. pipes and fittings with synthetic enamel white paint with
two coats over a ready mixed priming coat, both of approved quality
for new work :
For Waste line in toilets and Kitchen
15.14.1 32 mm dia. nominal bore Metre
15.14.2 40 mm dia. nominal bore Metre
15.14.3 50 mm dia. nominal bore Metre
15.15 Cutting chases in brick masonry walls for following diameter sand cast
iron/ centrifugally cast (spun) iron pipes and making good the same
with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded
stone aggregate 12.5 mm nominal size), including necessary plaster
and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :
For Waste line in toilets and Kitchen

15.15.1 50 mm dia Metre


15.16 Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i)
Single socketed pipes.
15.16.1 75 mm diameter Metre
15.16.2 110 mm diameter Metre

gdmspl 31 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


15.17 Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Single socketed pipes.

15.17.1 Single pushfit Coupler


15.17.1.1 75 mm diameter Each
15.17.1.2 110 mm diameter Each
15.18 Providing and fixing unplasticised -PVC pipe clips of approved design
to unplasticised - PVC rain water pipes by means of 50x50x50mm
hard wood plugs, screwed with M.S. screws of required length
including cutting brick work and fixing in cement mortar 1:4 (1
cement : 4 coarse sand) and making good the wall etc. complete.

15.18.1 75 mm Each
15.18.2 110 mm Each
15.19 Providing and fixing to the inlet mouth of rain water pipe cast iron Each
grating 15 cm diameter and weighing not less than 440 grams.
15.20 Providing and fixing of floor traps formed of Cast Iron 'P' traps Each
complete, including cost of cutting and making good the walls and
floors wherever required.
100 mm inlet and 100 mm outlet
15.21 Providing and fixing floor trap Extension Piece made out of 100 mm Each
dia M.S. pipe (heavy grade C-Class) of required length (upto 450 mm)
with 32 mm to 50 mm dia threaded maleable iron sockets ( maximum
4 nos.) welded as side inlets, neatly finished, inside and outside
painted with 2 coats of redoxide primer & 2 coats of synthetic enamel
paint, including the cost of jointing with floor trap with dripseal joint.

15.22 Providing and fixing floor drain points formed out of 100 X 50 mm dia Each
reducing elbow with suitable extension piece including cost of cutting
and making good the walls and floors wherever required.
15.23 Providing and fixing 125 mm dia round chrome plated bronze grating Each
with frame, screw down type embedded in floor, all complete.

gdmspl 32 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


15.24 Providing and fixing screwed down type nickel bronze alloy cast floor Each
cleanout with opening arrangements for soil / waste pipe and other
necessary fittings inlcuding jointing, all complete as per standard
detail.
For 100 mm dia pipe
15.25 Providing and fixing cleanout with opening arrangements by providing Each
300 mm long G.I. nipple welded to 6 mm thick flange sealed with 6
mm thick blank flange including nuts and bolts, rubber insertions etc.
all complete as per standard detail.
For 100 mm dia pipe
15.26 Providing and fixing single unequal plain junction of required degree : Each
100x100x75 mm
Sand cast iron S&S as per IS - 3989

15.27 Providing and fixing on wall face unplasticised Rigid PVC rain water Metre
pipes conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Single socketed pipes.
160 mm diameter

15.28 Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Single socketed pipes.

15.28.1 Single Coupler :


15.28.1.1 160 mm diameter Each
15.28.2 Bend 87.5
15.28.2.1 160 mm diameter Each
15.29 Providing and fixing unplasticised -PVC pipe clips of approved design Each
to unplasticised - PVC rain water pipes by means of 50x50x50mm
hard wood plugs, screwed with M.S. screws of required length
including cutting brick work and fixing in cement mortar 1:4 (1
cement : 4 coarse sand) and making good the wall etc. complete.
160 mm

gdmspl 33 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Total : Sub Head No. 15
Sub Head 16 : WATER SUPPLY
16.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with lamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction
of Engineer in Charge.
Internal work Exposed on wall

16.1.1 15 mm nominal outer dia .Pipes. Metre


16.1.2 20 mm nominal outer dia .Pipes. Metre
16.1.3 25 mm nominal outer dia .Pipes. Metre
16.1.4 32 mm nominal outer dia .Pipes. Metre
16.1.5 40 mm nominal outer dia .Pipes. Metre
16.1.6 50 mm nominal outer dia .Pipes. Metre
16.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer
in Charge
Concealed work including cutting chases and making good the walls
etc.

16.2.1 15 mm nominal outer dia .Pipes. Metre


16.2.2 20 mm nominal outer dia .Pipes. Metre
16.2.3 25 mm nominal outer dia .Pipes. Metre
16.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement ,trenching ,refilling & testing of
joints complete as per direction of Engineer in Charge.
External work

gdmspl 34 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


16.3.1 15 mm nominal outer dia .Pipes. Metre
16.3.2 20 mm nominal outer dia .Pipes. Metre
16.3.3 25 mm nominal outer dia .Pipes. Metre
16.3.4 32 mm nominal outer dia .Pipes. Metre
16.3.5 40 mm nominal outer dia .Pipes. Metre
16.3.6 50 mm nominal outer dia .Pipes. Metre
16.4 Making connection of G.I. distribution branch with G.I. main of
following sizes by providing and fixing tee,including cutting and
threading the pipe etc. complete
16.4.1 25 to 40 mm nominal bore Each
16.4.2 50 to 80 mm nominal bore Each
16.5 Providing and fixing of nickel plated brass/ nonferrous alloy fullyway
ball valve ( minimum working pressure of 20 bar ) with operating
handle of approved make.
16.5.1 15 mm dia Each
16.5.2 20 mm dia Each
16.5.3 25 mm dia Each
16.5.4 32 mm dia Each
16.5.5 40 mm dia Each
16.5.6 50 mm dia Each
16.6 Providing and fixing Cast Iron butterfly valve as per IS: 13095 of
Class PN 10, having epoxy coated disc, carbon steel shaft, EPDM /
nitrile rubber field replacible body lining and of approved make.
including a set of MS flanges, required nos. of nut & bolts all
complete.
16.6.1 65 mm dia ( with lever) No.
16.6.2 80 mm dia ( with lever) No.

gdmspl 35 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


16.11 Providing and fixing in position the medium class (Class B) G.I. pipes
(IS:1239) with all fittings, specials & clamps effecting proper
connections, cutting and making good the walls and floors etc.
(Internal Work). Note: Pipe work in shafts, ceiling voids and terrace
shall be supported/ fixed on MS structural supports with U-clamps
complete with nuts and washers.Cost for MS structural work for
supports shall be included in the rates all complete. ( At terrace level
and riser mains)

16.11.1 65 mm dia Metre


16.11.2 80 mm dia Metre
16.11.3 100 mm dia Metre
16.12 Painting G.I. pipes and fittings with synthetic enamel white paint with
two coats over a ready mixed priming coat, both of approved quality
for new
work :
16.12.1 65 mm dia Metre
16.12.2 80 mm dia Metre
16.12.3 100 mm dia Metre

gdmspl 36 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


16.13 Providing, Laying, Jointing and Testing of HDPE Pipes and Fittings.
The work shall be done as per specifications and in general shall
include:
a) Providing HDPE pipes (of PE 80 grade as per IS 4984-1995 ). The
pipes shall have a working pressure of PN 10.x
b) Providing fabricated and moulded fittings of same or higher grade
and upto 63 mm OD shall be rated PN 16 and 75 mm OD and above
shall be rated for PN 10.
Providing, laying and fixing HDPE compression type fittings (as
required, adaptor fittings, saddles, etc. including jointing, testing etc.
all complete. The compression fittings upto 63 mm OD shall be rated
PN 16 and 75 mm OD and above shall be rated for PN 10.
c) Laying in position in excavated trenches.
d) Jointing by heat fusion technique.
e) Providing and laying LDPE/PVC warning tape ( in florescent colour)
of size 25 mm wide and 50 micron thick. The warning tape shall be
laid 150 mm above the pipe crown.

16.13.1 90 mm dia. ( PN 10 ) Metre


16.13.2 110 mm dia. ( PN 10 ) Metre
16.13.3 160 mm dia. ( PN 10 ) Metre
Total : Sub Head No. 16
Sub Head 17 : SEWERAGE AND STORM WATER DRAINAGE
17.1 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes
with collars jointed with stiff mixture of cement mortar in the proportion
of 1 : 2 (1 cement : 2 fine sand) including testing of joints etc.
complete.
17.1.1 150 mm dia. R.C.C. pipe Metre
17.1.2 250 mm dia. R.C.C. pipe Metre
17.1.3 300 mm dia. R.C.C. pipe Metre
17.1.4 450 mm dia. R.C.C. pipe Metre
17.1.5 500 mm dia. R.C.C. pipe Metre
17.1.6 600 mm dia. R.C.C. pipe Metre

gdmspl 37 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


17.2 Constructing brick masonry manhole in cement mortar 1:4 ( 1 Each
cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8
graded stone aggregate 40mm nominal size), inside plastering 12mm
thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with
floating coat of neat cement and making channels in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
nominal size) finished with a floating coat of neat cement complete as
per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame
(light duty) 455x610 mm internal dimensions, total weight of cover and
frame to be not less than 38 kg (weight of cover 23 kg and weight of
frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5

17.3 Extra for depth for manholes. Metre


Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5

gdmspl 38 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


17.4 Constructing brick masonry circular type manhole 0.91 m internal dia Each
at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4
coarse sand), in side cement plaster 12 mm thick with cement mortar
1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat
cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size), and making necessary
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating
coat of neat cement, all complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade
designation) 560 mm internal diameter conforming to I.S. 12592, total
weight of cover and frame to be not less than 182 kg., fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12mm thick cement plaster at the external
surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5

17.5 Extra depth for circular type manhole 0.91m internal dia (at bottom) Metre
beyond 0.91 m to 1.67 m
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5

gdmspl 39 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


17.6 Providing orange colour safety foot rest of minimum 6 mm thick Each
plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross section as 23 mmx25
mm and over all minimum length 263 mm and width as 165 mm with
minimum 112 mm space between protruded legs having 2 mm tread
on top surface by ribbing or chequering besides necessary and
adequate anchoring projections on tail length on 138 mm as per
standard drawing and suitable to with stand the bend test and
chemical resistance test as per specifications and having
manufactures permanent identification mark to be visible even after
fixing, including fixing in manholes with 30x20x15 cm cement
concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal
size) complete as per design.

17.7 12 mm cement plaster of mix : sq. m.


For external surface plaster of 0.91 m dia, 1.22 m dia & 1.52 m dia
manhole
1:4 (1 cement: 4 coarse sand)
17.8 Constructing brick masonry road gully chamber 50x45x60 cm with Each
bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including
500x450 mm pre-cast R.C.C. horizontal grating with frame complete
as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5

17.9 Providing, Laying, Jointing and Testing of Under Ground Sewerage


Pipes
The work shall be done as per specifications and in general shall
include:
a) Providing UPVC drain pipes ( orange in colour) conforming to
IS:15328 and of class SN 8
b) Laying in position pipes in trenches.
c) Jointing with water tight sealing rings

17.9.1 110 mm dia Metre

gdmspl 40 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


17.10 Providing, Laying, Jointing and Testing of Under Ground Sewerage
Pipes
The work shall be done as per specifications and in general shall
include:
a) Providing UPVC drain pipes ( orange in colour) conforming to
IS:15328 and of class SN 4
b) Laying in position pipes in trenches.
c) Jointing with water tight sealing rings

17.10.1 a) 160 mm dia Metre


17.11 Providing and fixing square-mouth UPVC gully trap complete with
C.I. grating brick masonry chamber with water tight C.I. cover with
frame of 300 x300 mm size (inside) the weight of cover to be not less
than 4.50 kg and frame to be not less than 2.70 kg as per standard
design :
17.11.1 100x100 mm size P type Each
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
17.12 Extra for encasing the laid pipe with pea gravel (size 20mm), 150 mm
all around.
17.12.1 110 mm dia Metre
17.12.2 160 mm dia Metre
17.13 Constructing brick masonry water tight grease trap (with three Each
chambers , each of 0.6 M X 0.6 M in plan) with 75 class designation
bricks in cement mortar 1 : 5 ( 1 cement : 5 fine sand ) earth work,
excavation in all kinds of soil, foundation concrete 1 : 4 : 8 mix (1
cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal
size) inside and outside plastering 12 mm thick with cement mortar 1 :
3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat
cement including constructing baffle wall, stainless steel angles on
corners, stainless steel perforated plates with stainless steel lifting
handles in each chamber, inlet and outlet fittings in UPVC, double
seal C.I. covers complete as per standard design :
Inside size 1.8 m x 0.6 m and 1.2 m deep including three nos. 60x60
cm. C.I. Cover and frame (double seal weight of cover and frame not
less than 75 kg)

gdmspl 41 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


17.14 Extra for excavating trenches for pipes, cables etc. in all kinds of soil
for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over
corresponding basic item for depth upto 1.5 metre).
17.14.1 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm Metre
dia
17.14.2 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm Metre

17.15 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil
for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is
over corresponding basic item for depth upto 1.5 metre.)
17.15.1 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm Metre
dia
17.15.2 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm Metre

17.16 Constructing brick masonry circular manhole 1.52 m internal dia at


bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4
coarse sand) inside cement plaster 12 mm thick with cement mortar
1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat
cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size) and making necessary
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating
coat of neat cement, all complete as per standard design :

17.16.1 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade Each
designation) 560 mm internal diameter conforming to I.S. 12592, total
weight of cover and frame to be not less than 182 kg. fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12 mm thick cement plaster at the external
surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5

gdmspl 42 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


17.17 Extra depth for circular type manhole 1.52 m internal dia (at bottom) Metre
beyond 2.30 m :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
17.18 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse
sand : 10 graded stone aggregate 40 mm nominal size) up to
haunches of S.W. pipes including bed concrete as per standard
design :
For R.C.C. NP2 PIPE
17.18.1 150 mm diameter S.W. pipe Metre
17.18.2 250 mm diameter S.W. pipe Metre
17.18.3 300 mm diameter S.W. pipe Metre
Total : Sub Head No. 17
Sub Head 18 : MISCELLANEOUS ITEMS
18.1 Providing and fixing M.S. Tubular frames for doors, windows, Kg
ventilators and cupboard with rectangular/ L-Type sections, made of
1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish,
with profiles of required size, including fixing of necessary butt hinges
and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete
block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size)

18.2 Providing and fixing G.I. vent pipe with antimosquito grating of the Each
following sizes (for under ground/over head water tanks only):
80 mm dia
18.3 Providing and fixing in position following sizes pipe inserts with puddle
flanges, fabricated with heavy duty MS pipe pieces conforming to IS:
1239 and puddle flange made of 6 mm thick MS plate welded to the
pipe piece, entire piece hot dipped galvanised, all complete as per
Standard Detail, including fixing at desired position in the form work
for RCC walls / slabs before pouring of concrete.

18.3.1 0.91
1.66
25 mm`mmdiadeep
deep with
with S.F.R.C.
S.F.R.C. cover and No.
18.3.2 frame
32 mm dia( heavy
( heavy
duty,
duty,HD-20
HD-20 grade No.
designation) 560 mm internal diameter
conforming to IS 12592, total weight of
gdmspl cover and frame to be not less than 182 43 psda
kg. fixed in
in cement
cement concrete
concrete1:2:4
1 : 2 : 4 (1
cement(1: cement
2 coarse: 2 :coarse
4 graded
: 4 graded
stone
SCHEDULE OF RATES
1.66 `m
0.91 m deep
deep with
with S.F.R.C.
S.F.R.C. cover and
frame ( heavy ( heavy
duty,
duty,HD-20
HD-20 grade
Items designation) 560 mm internal Description
diameter Unit Quantity Rate Amount
18.3.3 40 mm dia
conforming to IS 12592, total weight of No.
cover
18.3.4 50 mmanddia frame to be not less than 182 No.
18.3.5 65 mm diain
kg. fixed in cement
cement concrete
concrete1:2:4
1 : 2 : 4 (1 No.
cement(1: cement
2 coarse: 2 :coarse
4 graded
: 4 graded
stone
18.3.6 80 mm aggregate
dia 20 20
aggregate
stone mmmmnominal
nominal size) No.
including
18.3.7 100 mm dia centering shuttering all No.
complete. (Excavation, foot rests and 12
18.3.8 150 mm dia No.
mm thick cemnet plaster at the external
18.3.9 250 mm shall
surface dia be paid for seperately) No.
Total : Sub Head No. 18
Sub Head 19: point wiring
19.1 Wiring for light point/fanpoint/exhaust fan point/call bell point with 1.5 Point
sq.mm.FRLS PVC insulated, copper conductor single core cable in
surface/recessed steel conduit, with modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC
insulated copper conductor single core cable etc. as required.
Group C

19.2 Wiring for light / power plug with 2x4 sq.mm. FRLS PVC insulated, M
copper conductor, single core cable in surface/recessed steel conduit
along with 1 No. 4 sq.mm FRLS PVC insulated copper conductor
single core cable for loop earthing as required

19.3 Wiring for circuit/ submain wiring along with earth wire with the
following sizes of FRLS PVC insulated copper conductor, single core
cable in surface/recessed steel conduit as required
19.3.1 2x1.5 sq.mm.+ 1x1.5 sq.mm. earth wire M
19.3.2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire M
19.3.3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire M
19.3.4 4 x 4 sq.mm. + 2 x 4 sq.mm. earth wire M
19.3.5 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire M
19.3.6 4 x 10 sq.mm. + 2 x 10 sq.mm. earth wire M
19.3.7 4 x 16 sq.mm. + 2 x 16 sq.mm. earth wire M
19.4 Supplying and drawing following pair 0.5 sq mm FRLS PVC insulated
annealed copper conductor, unarmored telephone cable in the
existing surface/recessed steel/ PVC conduit as required.
19.4.1 2 Pair M

gdmspl 44 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


19.4.2 20 Pair M
19.5 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid M
copper conductor PE insulated, shielded with fine tinned copper braid
and protected with PVC sheath in the existing surface/recessed
steel/PVC conduit as required.
19.6 Supplying and fixing of following sizes of steel conduit alonwith the M
accessories in surface/recess including painting in case of surface
conduit, or cutting the wall and making good the same in case of
recessed conduit as required :
25 mm
19.7 Supplying and fixing stepped type elctronic fan regulator on the Each
existing modular plate switch box including connection but excluding
modular plate etc. as required.
19.8 Supplying and fixing following size/modules, GI box alongwith Each
modular base & cover plate for modular switches in recess etc as
required. ( for telephone, TV outlets, Bell Push etc)
1 or 2 Module (75mmx75mm)
19.9 Supplying and fixing GI box with modular plate and cover in front on No.
surface or in recess, including providing and fixing 3 pin 5/6 amps.
modular socket outlet and 5/6 amps. Modular switch, connections etc.
as required. (For light plugs).
19.10 Supplying and fixing GI box with modular plate and cover in front on No.
surface or in recess, including providing and fixing 6 pin 5/6 & 15/16
amps. modular socket outlet and 15/16 amps. Modular switch,
connections etc. as required.
19.11 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction Each
box/ wooden block including connection etc. as required.
19.12 Installation, testing and commissioning of pre-wired, flourescent Each
fitting/compact flourescent fitting of all types, with all accessories and
tube etc. directly on ceiling/wall, including connection with 1.5 sqmm
FRLS PVC insulated, copper conductor, single core cable and
earthing etc, as required.

gdmspl 45 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


19.13 Installation, testing and commossioning of ceiling fan, including wiring Each
the down rods of standard length (upto 30cm) with 1.5 sq.mm. FRLS
PVC insulated, copper conductor, single core cable, incuding
providing and fixing phenolic laminated sheet cover on the fan box
etc. as required.
19.14 Installation of exhaust fan in the existing opening, including making Each
good the damage, connection, testing, commissioning etc. as
required.
Upto 450 mm sweep
19.15 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box Each
for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of
1.5 mm thick M.S. sheet with its top surface hacked for proper
bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by
means of 3.3 mm dia round headed screws, one lock at the corners.
Clamp shall be made of 12 mm dia M.S. bar bent to shape as per
standard drawing.

19.16 Supply, installation, testing and commissioning of Main Distribution


Frame Krone type with lockable box as required
19.16.1 20 Pair No.
19.16.2 200 Pair No.
Total:Subhead 19
Subhead 20 : Distribution Boards
20.1 Supplying and fixing following way prewired SP&N MCB distribution
board of steel sheet for 240 volts on surface/recess complete with
loose wire box, terminal connectors for all incoming and outgoing
circuits, duly prewired with suitable size FRLS PVC insulated copper
conductor up to terminal blocks, tinned copper bus bar, neutral link,
earth bar, din bar, detachable gland plate, interconnections, power
painted including earthing etc. as required, ( But without MCB/RCCB/
Isolator)

20.1.1 2+4way/6way, Double Door Each


20.1.2 2+8way/10way, Double Door Each
20.1.3 2+12way/14way, Double Door Each

gdmspl 46 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


20.2 Supplying and fixing following way prewired TP&N MCB distribution
board of steel sheet for 415 volts on surface/recess complete with
loose wire box, terminal connectors for all incoming and outgoing
circuits, duly prewired with suitable size FRLS PVC insulated copper
conductor up to terminal blocks, tinned copper bus bar, neutral link,
earth bar, din bar, detachable gland plate, interconnections, power
painted including earthing etc. as required, ( But without MCB/RCCB/
Isolator)

20.2.1 4 way (4+12), Double Door Each


20.2.2 6 way (4+18), Double Door Each
20.2.3 8 way (4+24), Double Door Each
20.2.4 12 way (4+36), Double Door Each
20.3 Supplying and fixing following way prewired vertical type TP&N MCB Each
distribution board of steel sheet for 415 volts on surface/recess
complete with loose wire box, dust protected, duly powder painted,
inclusive of 200 amps tinned copper busbar, common neutral link,
earth bar, din bar for mounting MCB's, terminal connectors for all
incoming and outgoing circuits, duly prewired with adequate size
FRLS PVC insulated copper conductor up to terminal
connector/neutral link, earthing etc as required ( But without
MCB/RCCB/ Isolator). (Note: Prewired vertical type MCB TPDB is
normally used where 3 phase outlets are required.)
12 Way Double Door

20.4 Supplying and fixing of following rating, 415 volts, 'C' curve,miniature
circuit breaker suitable for inductive load of following poles in the
existing MCB DB complete with connections, testing and
commissioning etc. as required
20.4.1 32 amp FP MCB Each
20.4.2 40 amp FP MCB Each
20.4.3 63 amp FP MCB Each

gdmspl 47 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


20.5 Supply, installation, testing and commissioning of M.V. cubicle type
suitable for 415 V AC three phase 4 wire system, 35kA fault
level,totally enclosed floor mounted free standing type, dust, damp
and vermin proof Panel complete with incoming and outgoing
switchgears and meters, M.V. danger notice plate, interconnections
with suitable capacity aluminium leads/solid aluminium strips, rods,
connection of incoming and outgoing cables with thimbles, powder
coated painted complete as per drawing as required.

20.5.1 Main Panel at Ground Floor


Meter Compartment (Without meter)
Meter compartment of suitable size with CTs controlled (800/5A) 3
phase 4 wire dual direct type kWHr meters. - 2 Nos.
2 Nos. 800A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker with microprocessor release and opration counter.
2 No. VIF meter (VIF) with CT's 800/5A & control of 2A SP MCB
2 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :
1000A Phase and 500A Neutral TPN busbars of aluminium with
colour coded heat shrinkable sleeves and with SMC/DMC supports at
every 600mm intervals and at both ends
BUS COUPLERS
1 No.800A, 415V, 50kA rupturing capacity, EDO FP Air Circuit Breaker
as B/C without protective releases but with Under voltage release and
ON-OFF indication lamps.
Outgoings
4 Nos. 630A, 415V, Ics=Icu=35kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
4 Nos. 160A, 415V, Ics=Icu=35kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
2 Nos. 63A 10kA FP MCB Each
20.5.2 Common area Panel at Ground Floor
1 No. 160A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle

gdmspl 48 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


1 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :
200A Phase and Neutral TPN busbars of aluminium with colour
coded heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
OUTGOINGS :
4 Nos. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
2 Nos. 100A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
2 Nos. 63A 10kA FP MCB
2 Nos. 40A 10kA FP MCB Each
20.5.3 Floor Panels (Ground Floor)
1 No. 160 A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :
200A Phase and Neutral TPN busbars of aluminium with colour
coded heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
OUTGOINGS :
1 No. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
13 Nos. 32A 10kA FP MCB
15 Nos. 40A 10kA FP MCB Each
20.5.4 Floor Panels (First Floor)
1 No. 160 A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :

gdmspl 49 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


200A Phase and Neutral TPN busbars of aluminium with colour
coded heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
OUTGOINGS :
1 No. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
12 Nos. 63A 10kA FP MCB
18 Nos. 32A 10kA FP MCB
10 Nos. 40A 10kA FP MCB Each
20.5.5 Floor Panels (Second Floor)
1 No. 160 A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :
200A Phase and Neutral TPN busbars of aluminium with colour
coded heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
OUTGOINGS :
1 No. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
5 Nos. 63A 10kA FP MCB
8 Nos. 32A 10kA FP MCB
7 Nos. 40A 10kA FP MCB Each
20.5.6 Floor Panels (Third Floor)
1 No. 160 A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :

gdmspl 50 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


200A Phase and Neutral TPN busbars of aluminium with colour
coded heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
OUTGOINGS :
1 No. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
7 Nos. 63A 10kA FP MCB
10 Nos. 32A 10kA FP MCB
5 Nos. 40A 10kA FP MCB Each
20.5.7 Floor Panels (Fourth Floor)
1 No. 125 A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :
200A Phase and Neutral TPN busbars of aluminium with colour
coded heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
OUTGOINGS :
2 Nos. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
8 Nos. 32A 10kA FP MCB
6 Nos. 40A 10kA FP MCB Each
20.5.8 Floor Panels (Fifth Floor)
1 No. 125 A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB

BUSBARS :
200A Phase and Neutral TPN busbars of aluminium with colour
coded heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
OUTGOINGS :

gdmspl 51 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


2 Nos. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN MCCB with
phase spreader & extended rotary handle
5 Nos. 32A 10kA FP MCB
10 Nos. 40A 10kA FP MCB Each
20.5.9 Main LT Panel (Academic Block)
INCOMERS : FROM 2 Nos. 630 kVA TRANSFORMERS
Each Incomer have following
1 No. 1000A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker with microprocessor release and opration counter.
1 set of indicating lamps to indicate ON, OFF and TRIP for breaker

1 Set of phase indicating lights LED type with control of 2A SP MCB

1 Set 0-1000A ammeter with Class-1 1000/5A CTs


1 No. Multifunction meter (MFM) with Class-1 1000/5A CTs and RS
485 port
1 No. CL-1 15VA 1000/5A CTs for APFCR
1 Set of over/under voltage realy with CL-5P10 15VA 1000/5A CTs
contacts for trip and alarm
1 No.15kVAR Fix type Capacitor bank each 63A, 415V, Ics=Icu=35kA
rupturing capacity, TPN, MCCB and 63A TP capacitor duty contactor
with ON-OFF push buttons and set of indicating lights.

INCOMERS : FROM 2 Nos. 500 kVA DG SETS


Each incomer have following
1 No. 800A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker with microprocessor release and opration counter.
1 set of indicating lamps to indicate ON, OFF and TRIP for breaker

1 Set of phase indicating lights LED type with control of 2A SP MCB

1 Set 0-800A ammeter with Class-1 800/5A CTs


1 No. Multifunction meter (MFM) with Class-1 800/5A CTs and RS 485
port
1 Set of over/under voltage realy with CL-5P10 15VA 800/5A CTs
contacts for trip and alarm

gdmspl 52 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


1 Set Reverse power relay with CL-5P10 15VA 800/5A CTs contacts
for trip and alarm
INCOMERS : FROM 1 No. 250 kVA DG SETS
Each incomer have following
1 No. 630A/400A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker with microprocessor release and opration counter.
1 set of indicating lamps to indicate ON, OFF and TRIP for breaker

1 Set of phase indicating lights LED type with control of 2A SP MCB

1 Set 0-400A ammeter with Class-1 400/5A CTs


1 No. Multifunction meter (MFM) with Class-1 400/5A CTs and RS 485
port
1 Set of over/under voltage realy with CL-5P10 15VA 400/5A CTs
contacts for trip and alarm
1 Set Reverse power relay with CL-5P10 15VA 400/5A CTs contacts
for trip and alarm
BUS BAR
1000A Phase and 500A Neutral TPN busbars of aluminium with
colour coded heat shrinkable sleeves and with SMC/DMC supports at
every 600mm intervals and at both ends
315A Phase and Neutral TPN busbars of aluminium with colour coded
heat shrinkable sleeves and with SMC/DMC supports at every
600mm intervals and at both ends
BUS COUPLERS
1 No.1000A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker as B/C without protective releases but with Under voltage
release and ON-OFF indication lamps.
1 No. 630A/400A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker as B/C without protective releases but with Under voltage
release and ON-OFF indication lamps.
INTERLOCKING :

gdmspl 53 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Interlocking system with electrical Interlocking between Five Incomers
and two buscoupler for operation, so that at any time no two different
power supply shall be ON & Conected together as per interlocking
scheme as shown on SLD drwing No. KES-1339 - E -101.

PLC PANEL
Programmable Logic Controller (PLC Based AMF cum load
Mangement Control Panel) to control of 3 Nos. D.G. Sets. incomers
and 2 Nos. Tranformers incomers and 2 Nos. Bus Couplers with
each provided the following:
1. 3-way On/Off Master/ self selector switch for Auto Load
Mangement by auto start/stop of required Gensets.
2. Complete AMF Operation
3. Protection for Low level lub oil (LLOP), High Water Temperature
(HWT), Three Times start on failure lock the D.G., U/V, O/V, U/F &
O/F.
4.Suitable Nos. of Indication Lights, Push Buttons, Selector Switches,
Battery Charger CVCC type with auxiliary relays and Auxliary
contactors etc. complete as required.
OUTGOINGS :
Note : All outgoing feeders shall have ammeter, inbuilt selector switch
and set of Class-1 CTs, ON indicating lamps & Phase spreaders.

BUS SECTION-1
2 Nos. 800A, 415V, 50kA rupturing capacity, MDO TPN Air Circuit
Breaker with Thermal Magnetic (TM) releases, OC/SC protection.

2 Nos.400A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with


extended rotary handle
1 No. 400A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
extended rotary handle with Thermal Magnetic (TM) releases, OC/SC
protection and operation counter. for 200 kVAR capacitor panel - 1

BUS SECTION-2

gdmspl 54 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


2 Nos. 800A, 415V, 50kA rupturing capacity, MDO TPN Air Circuit
Breaker with Thermal Magnetic (TM) releases, OC/SC protection.

1 Nos.400A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with


extended rotary handle
1 No. 400A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
extended rotary handle with Thermal Magnetic (TM) releases, OC/SC
protection and operation counter. for 200 kVAR capacitor panel - 1

BUS SECTION-3
2 Nos.400A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with Each
extended rotary handle
20.5.10 Main LT Panel (PG Hostel)
INCOMERS : FROM 2 Nos. 500 kVA TRANSFORMERS
Each Incomer have following
1 No. 800A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker with microprocessor release and opration counter.
1 set of indicating lamps to indicate ON, OFF and TRIP for breaker

1 Set of phase indicating lights LED type with control of 2A SP MCB

1 Set 0-800A ammeter with Class-1 800/5A CTs


1 No. Multifunction meter (MFM) with Class-1 800/5A CTs and RS 485
port
1 No. CL-1 15VA 800/5A CTs for APFCR
1 Set of over/under voltage realy with CL-5P10 15VA 800/5A CTs
contacts for trip and alarm
1 No.10kVAR Fix type Capacitor bank each 63A, 415V, Ics=Icu=35kA
rupturing capacity, TPN, MCCB and 63A TP capacitor duty contactor
with ON-OFF push buttons and set of indicating lights.

INCOMERS : FROM 2 Nos. 500 kVA DG SETS


Each incomer have following
1 No. 800A, 415V, 50kA rupturing capacity, EDO FP Air Circuit
Breaker with microprocessor release and opration counter.

gdmspl 55 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


1 set of indicating lamps to indicate ON, OFF and TRIP for breaker

1 Set of phase indicating lights LED type with control of 2A SP MCB

1 Set 0-800A ammeter with Class-1 800/5A CTs


1 No. Multifunction meter (MFM) with Class-1 800/5A CTs and RS 485
port
1 Set of over/under voltage realy with CL-5P10 15VA 800/5A CTs
contacts for trip and alarm
1 Set Reverse power relay with CL-5P10 15VA 800/5A CTs contacts
for trip and alarm
BUS BAR
1000A Phase and 500A Neutral TPN busbars of aluminium with
colour coded heat shrinkable sleeves and with SMC/DMC supports at
every 600mm intervals and at both ends
BUS COUPLERS
1 No.800A, 415V, 50kA rupturing capacity, EDO FP Air Circuit Breaker
as B/C without protective releases but with Under voltage release and
ON-OFF indication lamps.
INTERLOCKING :
Interlocking system with electrical Interlocking between Four Incomers
and One buscoupler for operation, so that at any time no two different
power supply shall be ON & Conected together as per interlocking
scheme as shown on SLD drwing No. KES-1339 - E -101.

PLC PANEL
Programmable Logic Controller (PLC Based AMF cum load
Mangement Control Panel) to control of 2 Nos. D.G. Sets. incomers
and 2 Nos. Transformers incomers and 1 No. Bus Couplers with
each provided the following:
1. 3-way On/Off Master/ self selector switch for Auto Load
Mangement by auto start/stop of required Gensets.
2. Complete AMF Operation
3. Protection for Low level lub oil (LLOP), High Water Temperature
(HWT), Three Times start on failure lock the D.G., U/V, O/V, U/F &
O/F.

gdmspl 56 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


4.Suitable Nos. of Indication Lights, Push Buttons, Selector Switches,
Battery Charger CVCC type with auxiliary relays and Auxliary
contactors etc. complete as required.
OUTGOINGS :
Note : All outgoing feeders shall have ammeter, inbuilt selector switch
and set of Class-1 CTs, ON indicating lamps & Phase spreaders.

BUS SECTION-1
3 Nos.315A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
extended rotary handle
2 Nos.200A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
extended rotary handle
1 No. 315A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
extended rotary handle with Thermal Magnetic (TM) releases, OC/SC
protection and operation counter. for 160 kVAR capacitor panel - 2

BUS SECTION-2
3 Nos.315A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
extended rotary handle
2 Nos.250A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
extended rotary handle
1 No. 315A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with Each
extended rotary handle with Thermal Magnetic (TM) releases, OC/SC
protection and operation counter. for 160 kVAR capacitor panel - 2

Total: Subhead 20
Subhead 21: Earthing
21.1 Earthing with G.I. earth pipe 4.5 meter long, 40mm dia including Each
accessories, and providing masonry enclosure with cover plate having
locking arrangement and watering pipe etc. with charcoal/coke and
salt as required.
21.2 Earthing with G.I. earth plate 600 mm X 600 mm X 3 mm thick Each
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 metre long
etc. with charcoal/ coke and salt as required.

gdmspl 57 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


21.3 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick Each
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 metre long
etc. with charcoal/ coke and salt as required. (for lift)
21.4 Supplying and laying 25 mm X 5 mm cooper strip at 0.50 meter below M
ground as strip earth electrode including connection/ terminating with
G.I. with nut, bolt, spring, washer etc as required. ( Jointing shall be
done by overlapping and with 2 sets of nut bolt & spring washer
spaced at 50mm )
21.5 Supplying and laying 25 mm X 5 mm G.I. strip at 0.50 meter below M
ground as strip earth electrode including connection/ terminating with
G.I. with nut, bolt, spring, washer etc as required. ( Jointing shall be
done by overlapping and with 2 sets of nut bolt & spring washer
spaced at 50mm )
21.6 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. Each
pipe from earth electrode including connection with brass nut, bolt,
spring, washer excavation and re-filling etc. as required.
21.7 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe M
from earth electrode including connection with brass nut, bolt, spring,
washer excavation and re-filling etc. as required.
21.8 Providing and fixing 25 mm x 5 mm Copper strip on surface or in M
recess for connection etc. as required.
21.9 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess M
for connection etc. as required.
21.10 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for M
loop earthing as required.
Total: Subhead 21
Subhead 22: Cable, Cable Tray and Miscellaneous Items
22.1 Supplying and installing Following size of perforated pre-painted M.S.
cable trays with perforation not more than 17.5% in convenient
sections, joined with connectors, suspended from the ceiling with M.S.
suspenders including bolts & nuts, painting suspenders etc as
required.
22.1.1 300mm widthx50mm depthx1.6mm thickness M

gdmspl 58 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


22.2 Supplying and installing Following size of perforated pre-painted M.S.
cable trays bends with perforation not more than 17.5% joined with
connectors, suspended from the ceiling with M.S. suspenders
including bolts & nuts, painting suspenders etc as required.
Note: As per Site Requirement

22.2.1 300mm widthx50mm depthx1.6mm thickness Each


22.3 Laying and fixing of one number PVC insulated and PVC sheathed /
XLPE power cable of 1.1 KV grade of following size in the existing
RCC/HUME/Metal pipe as required.
22.3.1 Upto 35 sq. mm M
22.3.2 Above 35 sq. mm and upto 95 sq. mm M
22.3.3 Above 95 sq. mm and upto 185 sq. mm M
22.3.4 Above 185 sq. mm and upto 400 sq. mm M
22.4 Laying and fixing of one number PVC insulated and PVC sheathed /
XLPE power cable of 1.1 KV grade of following size on cable tray as
required.
22.4.1 Upto 35 sq. mm (clamped with 1 mm thick saddle) M
22.6 Supplying and making indoor end termination with brass compression
gland and aluminium lugs for following size of PVC insulated and PVC
sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.
22.6.1 3 X 10 sq. mm Each
22.6.2 3.5 x 25 sqmm Each
22.6.3 3.5 x 70 sqmm Each
22.6.4 3.5 x 95 sqmm Each
22.6.5 3.5 x 185 sqmm Each
22.6.6 3.5 x 240 sqmm Each
22.6.7 3.5 x 300 sqmm Each
22.6.8 4 x 10 sq.mm. Each
22.6.9 4 x 16 sq.mm. Each
22.7 Supplying following size of PVC insulated and PVC sheathed / XLPE
aluminium armoured conductor cable of 1.1 KV grade as required.

22.7.1 3 X 10 sq. mm M
22.7.2 3.5 x 25 sqmm M

gdmspl 59 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


22.7.3 3.5 x 70 sqmm M
22.7.4 3.5 x 95 sqmm M
22.7.5 3.5 x 185 sqmm M
22.7.6 3.5 x 240 sqmm M
22.7.7 3.5 x 300 sqmm M
22.7.8 4 x 10 sq.mm. M
22.7.9 4 x 16 sq.mm. M
22.8 Supplying and laying of one number Double walled corrugated high
density polyethylene pipe having corrugation on the outer wall and
plain surface inner wall conforming to IS: 14930 Part- I and II
complete with necessary HDPE fitting for protection of 1.1KV grade
under ground cable directly in ground at a depth of 50cm including
excavating and refilling the trench etc. as required.

22.8.1 77mm outer dia M


22.8.2 110mm outer dia M
22.8.3 145mm outer dia M
22.8.4 175mm outer dia M
22.8.5 300 mm outer dia M
22.9 Constructing masonry Chamber 45x45x45 cm inside, in brick work in No.
cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with
C.I. surface box 100mm top diameter, 160 mm bottom diameter and
180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size ) , i/c necessary excavation, foundation concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design :
450 x 450 x 450 mm deep

gdmspl 60 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


22.10 Constructing masonry Chamber 60x60x75 cm inside, in brick work in No.
cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with
C.I. surface box 100mm top diameter, 160 mm bottom diameter and
180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size ) , i/c necessary excavation, foundation concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5

22.11 Constructing masonry Chamber 90x90x100 cm inside, in brick work in No.


cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with
C.I. surface box 100mm top diameter, 160 mm bottom diameter and
180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size ) , i/c necessary excavation, foundation concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5

22.12 Laying of one number PVC insulated and PVC sheathed / XLPE M
power cable of 11 KV grade of following size in the existing RCC/
HUME/ METAL pipe as required.
Above 120 sq. mm and upto 400 sq. mm
22.13 supplying and making indoor cable end termination with heat Each
shrinkable jointing kit complete with all accessories including lugs
suitable for following size of 3 core, XLPE aluminium conductor cable
of 11 KV grade as required.
240 Sq.mm.

gdmspl 61 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


22.14 Supplying of following sizes of 11 kV grade aluminium conductor M
XLPE armoured cable conforming to IS : 7098 (part-2)
3C 240 Sq.mm. Al
22.15 Fabricating,supplying and installing following size of Hot-Dip M
Galvanised Raceways including horizontal and vertical bends and
other accessories as required and duly suspended from the ceiling
with 10 mm dia fully threaded GI suspenders and galvanised 'C'
channel mount fixed to ceiling with expension bolts. Raceway shall be
complete with removable 3 mm thick GI cover, knock out holes on
sides and fixing accessories earthing with 8 SWG copper earth wire
complete
250 mm wide and 50 mm deep Raceways (sheet thickness 2.0mm)

Total: Subhead 22
Subhead 23: Rising Mains
23.1 Supplying, installing on wall, testing and commissioning of following
capacity Air Insulated Compact Type Rising Mains for use on 3 phase
4 wire 415 volts, 50Hz A.C. supply with enclosure made of 1.6mm
thick steel sheet duly powder coated in convenient sections complete
with 4 Nos aluminium bus bars, necessary joints & expansion joints,
fire barrier at each floor, provision of tapping at every metre,
continuous earthing with 2 Nos aluminium strip of suitable size (one
on each side) including, G.I. clamping brackets,
angle iron bracket, steel fasteners, connecting to earthing system
etc. as required

23.1.1 200 amps 15KA SC for 1 sec Meter


23.1.2 315 amps 25KA SC for 1 sec Meter
23.1.3 400 amps 30KA SC for 1 sec Meter
23.1.4 500 amps 35KA SC for 1 sec Meter

gdmspl 62 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


23.2 Supplying, installing, connecting to existing Air Insulated Compact
Type bus trunking/ rising mains, testing and commissioning of
following capacity Plug In/ Tap Off Box for use on 3 phase 4 wire 415
volts, 50Hz A.C. supply with 1.6mm thick steel sheet enclosure
duly powder coated with provision of MCCB (but without MCCB)
complete etc. as required

23.2.1 125 amps 15KA SC for 1 sec Each


23.2.2 200 amps 25KA SC for 1 sec Each
23.3 Providing and fixing following rating and breaking capacity and pole
MCCB in existing cubicle panel board including drilling holes in
cubicle panel, making connections, etc. as required.
23.3.1 630 Amp, 50KA, FPMCCB Each
Total: Subhead 23
Subhead 24: Fire Alarm System
24.1 Supplying, laying and connecting of following size 1.1 kV grade M
copper conductor control cable (conforming to IS:1554 Part I) on wall
or on existing cable tray/ in existing pipe/trench with clamping,
dressing or drawn in existing ducts all as required.
2X 1.5 sq.mm.unarmoured cable
24.2 Supply, installing connecting up, testing and commissioning of the
following fire alarm equipment :
24.2.1 Addressable Manual call point with builtin fault isolator No.
24.2.2 Addressable loop powered Hooter/Sounder with builtin fault isolator No.

24.3 Supply, installing, testing and commissioning of optical analog No.


addressable Smoke Detectors with builtin fault isolator'.
24.4 Supply, installing, testing and commissioning of analog addressable No.
Heat Detectors with builtin fault isolator'.

gdmspl 63 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


24.5 Supply, installation , testing & commissioning of Analogue No.
Addressable Fire Alarm Panel of approved make and having following
features
No. of Loops : 12 Loop (Each loop shall have minimum capacity of
200 Devices)
Salient Features : LCD Display (Min. 80 Characters), Fire Detection &
Alarm Panel up to 126 panels ,complete with sufficient numbers of
programmable relay controls for controlling AHUs, pressurization fans,
ventilation fans at fire pump room,Built-in battery backup with battery
charger, Operator control switches like Acknowledge, Alarm Silence,
Alarm activate, System reset etc., LED indicators for Warnings and
other features as per specifications.

Total: Subhead 24
Subhead 25: Lightning Protection System
25.1 Providing and fixing of lightning conductor finial, made of 25 mm dia Each
300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6
mm thick G.I. base plate including holes etc. complete as required.

25.2 Jointing copper / G.I. tape (with another copper/ G I tape, base of the Each
finial or any other metallic object) by riveting / nut bolting/ sweating
and soldering etc as required.
25.3 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or M
surface of wall for lightning conductor complete as required. (For
horizontal run)
25.4 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or M
surface of wall for lightning conductor complete as required. (For
vertical run)
25.5 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. Each
strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and
spring washers etc. complete as required.
25.6 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode M
directly in ground as required.
Total: Subhead 25
Subhead 26: Package Type Substations
26.1 400kVA PACKAGE TYPE SUBSTATION (For Type-E and Type-F)

gdmspl 64 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Supply, installation, testing and commissioning of 11KV/433V
package type outdoor substation consisting of following :
HT COMPARTMENT
Breaker
Supply, Installation, Testing & Commissioning of 11kv, 21kA, SF6
insulated 3-way non extensible compact ring main unit comprising 2
nos of load break switches as incomer & outgoing of 630A with
integral earth switch, with neon live cable indicators and 1 no. of
vacuum or SF6 circuit breaker of 630A with integral earth switch, with
self powered over current and earth fault realy, with shunt trip coil of
230V AC, with push button for circuit breaker manual tripping, with
SF6 gas pressure monitor, pad locking facility with degree of IP67
protection. Make: Schnieder / ABB / C&S : 1No.

Current Transformer
660V, Resin cast, Single phase, 75/5A, 5VA, Cl-1.0, Qty-3Nos
Potential Transformer
11kV, Resin cast, Three phase, Ratio 11kV/110V, 50VA, Cl-1.0, ILV
12/28/75kV, VF 1.2 continuous, 1.9 for 8 Hours with HRC fuses on HT
LT side , Qty-1No
Metering
MFM, Cl-1.0, Digital, Model: EM6400, Qty : 1No
Indicating Lamps
One set, Make : Teknic/Vaishno
TRANSFORMER COMPARTMENT
Transformer
11kV/433V, 400kVA, 3 Phase, 50Hz, Cast Resin Dry type, Dyn11, Air
Natural Cooled, Copper wound, With Off Load Tap Changer, Tap
range +5 to 5% in steps 2.5%, With OTI & WTI (Oil & Winding temp
indicator )
LT COMPARTMENT
Switchgears
2 Nos. 630A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
4 Nos. 100A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle

gdmspl 65 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Bus Coupler
1 No. 100A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 No. Auto transformer switch of 100A Make : ASCO by EMERSON

Metering
Ammeter, Cl-1.0, Digital
Voltmeter, Cl-1.0, Digital
Switches
Ammeter selector, Voltmeter selector in built type,
Indicating Lamps
Two sets, Make : Teknic/Vaishno
LT CTs
660V, Resin cast, 630/5A, 5VA, and 100/5A, 5VA Cl 1.0
Enclosure - Sheet steel Thickness
2.0 mm for non-load bearing members , CRCA
2.0 mm for load bearing members, CRCA
100 X 50 , ISMC channel for base
Degree of Protection
IP53 for HT / LT Compartment
IP23 for Transformer compartment
Applicable standard
IEC : 62271-202
Interconnection
1R x 3c X 95 Sq mm HT XLPE CABLE between HT unit and
Transformer
Suitable cross section Aluminium bus bar between Transformer and
LT unit
Paint shade
Dark admiralty as per shade 632 of IS:5 for exterior, Ultra blue for
Canopy and Black for base frame, Pure polyester powder coated
Cable entry
HT & LT Power cables bottom side Each
26.2 315kVA PACKAGE TYPE SUBSTATION (For Type-A and VIP Guest
House)

gdmspl 66 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Supply, installation, testing and commissioning of 11KV/433V
package type outdoor substation consisting of following :
HT COMPARTMENT
Breaker
Supply, Installation, Testing & Commissioning of 11kv, 21kA, SF6
insulated 3-way non extensible compact ring main unit comprising 2
nos of load break switches as incomer & outgoing of 630A with
integral earth switch, with neon live cable indicators and 1 no. of
vacuum or SF6 circuit breaker of 630A with integral earth switch, with
self powered over current and earth fault realy, with shunt trip coil of
230V AC, with push button for circuit breaker manual tripping, with
SF6 gas pressure monitor, pad locking facility with degree of IP67
protection. Make: Schnieder / ABB / C&S : 1No.

Current Transformer
660V, Resin cast, Single phase, 75/5A, 5VA, Cl-1.0, Qty-3Nos
Potential Transformer
11kV, Resin cast, Three phase, Ratio 11kV/110V, 50VA, Cl-1.0, ILV
12/28/75kV, VF 1.2 continuous, 1.9 for 8 Hours with HRC fuses on HT
LT side , Qty-1No
Metering
MFM, Cl-1.0, Digital, Model: EM6400, Qty : 1No
Indicating Lamps
One set, Make : Teknic/Vaishno
TRANSFORMER COMPARTMENT
Transformer
11kV/433V, 315kVA, 3 Phase, 50Hz, Cast Resin Dry type, Dyn11, Air
Natural Cooled, Copper wound, With Off Load Tap Changer, Tap
range +5 to 5% in steps 2.5%, With OTI & WTI (Oil & Winding temp
indicator )
LT COMPARTMENT
Switchgears
3 Nos. 200A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
1 No. 100A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle

gdmspl 67 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


2 Nos. 40A, 10kA MCB
1 No. Auto transformer switch of 500A Make : ASCO by EMERSON

Metering
Ammeter, Cl-1.0, Digital
Voltmeter, Cl-1.0, Digital
Switches
Ammeter selector, Voltmeter selector in built type,
Indicating Lamps
Two sets, Make : Teknic/Vaishno
LT CTs
660V, Resin cast, 200/5A, 5VA, and 100/5A, 5VA Cl 1.0,
Enclosure - Sheet steel Thickness
2.0 mm for non-load bearing members , CRCA
2.0 mm for load bearing members, CRCA
100 X 50 , ISMC channel for base
Degree of Protection
IP53 for HT / LT Compartment
IP23 for Transformer compartment
Applicable standard
IEC : 62271-202
Interconnection
1R x 3c X 95 Sq mm HT XLPE CABLE between HT unit and
Transformer
Suitable cross section Aluminium bus bar between Transformer and
LT unit
Paint shade
Dark admiralty as per shade 632 of IS:5 for exterior, Ultra blue for
Canopy and Black for base frame, Pure polyester powder coated
Cable entry
HT & LT Power cables bottom side Each
26.3 500kVA PACKAGE TYPE SUBSTATION (For P.G. Hostels, Student
Dining and WSC-1)
Supply, installation, testing and commissioning of 11KV/433V
package type outdoor substation consisting of following :
HT COMPARTMENT

gdmspl 68 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Breaker
Supply, Installation, Testing & Commissioning of 11kv, 21kA, SF6
insulated 3-way non extensible compact ring main unit comprising 2
nos of load break switches as incomer & outgoing of 630A with
integral earth switch, with neon live cable indicators and 1 no. of
vacuum or SF6 circuit breaker of 630A with integral earth switch, with
self powered over current and earth fault realy, with shunt trip coil of
230V AC, with push button for circuit breaker manual tripping, with
SF6 gas pressure monitor, pad locking facility with degree of IP67
protection. Make: Schnieder / ABB / C&S : 1No.

Current Transformer
660V, Resin cast, Single phase, 75/5A, 5VA, Cl-1.0, Qty-3Nos
Potential Transformer
11kV, Resin cast, Three phase, Ratio 11kV/110V, 50VA, Cl-1.0, ILV
12/28/75kV, VF 1.2 continuous, 1.9 for 8 Hours with HRC fuses on HT
LT side , Qty-1No
Metering
MFM, Cl-1.0, Digital, Model: EM6400, Qty : 1No
Indicating Lamps
One set, Make : Teknic/Vaishno
TRANSFORMER COMPARTMENT
Transformer
11kV/433V, 500kVA, 3 Phase, 50Hz, Cast Resin Dry type, Dyn11, Air
Natural Cooled, Copper wound, With Off Load Tap Changer, Tap
range +5 to 5% in steps 2.5%, With OTI & WTI (Oil & Winding temp
indicator )
LT COMPARTMENT
Switchgears
Air circuit breaker, 4P, 433V, 800A, 50kA, Microprocessor (Master
pack- MVS-ET2) based release, Fixed with (O/L,S/C,E/F) Protection,
Qty: 1No
Metering
Ammeter, Cl-1.0, Digital
Voltmeter, Cl-1.0, Digital
Switches

gdmspl 69 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Ammeter selector, Voltmeter selector in built type,
Indicating Lamps
Two sets, Make : Teknic/Vaishno
LT CTs
660V, Resin cast, 800/5A, 5VA, Cl 1.0,
Enclosure - Sheet steel Thickness
2.0 mm for non-load bearing members , CRCA
2.0 mm for load bearing members, CRCA
100 X 50 , ISMC channel for base
Degree of Protection
IP53 for HT / LT Compartment
IP23 for Transformer compartment
Applicable standard
IEC : 62271-202
Interconnection
1R x 3c X 95 Sq mm HT XLPE CABLE between HT unit and
Transformer
Suitable cross section Aluminium bus bar between Transformer and
LT unit
Paint shade
Dark admiralty as per shade 632 of IS:5 for exterior, Ultra blue for
Canopy and Black for base frame, Pure polyester powder coated
Cable entry
HT & LT Power cables bottom side Each
26.4 630kVA PACKAGE TYPE SUBSTATION (For Academic Block)
Supply, installation, testing and commissioning of 11KV/433V
package type outdoor substation consisting of following :
HT COMPARTMENT
Breaker

gdmspl 70 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Supply, Installation, Testing & Commissioning of 11kv, 21kA, SF6
insulated 3-way non extensible compact ring main unit comprising 2
nos of load break switches as incomer & outgoing of 630A with
integral earth switch, with neon live cable indicators and 1 no. of
vacuum or SF6 circuit breaker of 630A with integral earth switch, with
self powered over current and earth fault realy, with shunt trip coil of
230V AC, with push button for circuit breaker manual tripping, with
SF6 gas pressure monitor, pad locking facility with degree of IP67
protection. Make: Schnieder / ABB / C&S : 1No.

Current Transformer
660V, Resin cast, Single phase, 75/5A, 5VA, Cl-1.0, Qty-3Nos
Potential Transformer
11kV, Resin cast, Three phase, Ratio 11kV/110V, 50VA, Cl-1.0, ILV
12/28/75kV, VF 1.2 continuous, 1.9 for 8 Hours with HRC fuses on HT
LT side , Qty-1No
Metering
MFM, Cl-1.0, Digital, Model: EM6400, Qty : 1No
Indicating Lamps
One set, Make : Teknic/Vaishno
TRANSFORMER COMPARTMENT
Transformer
11kV/433V, 630kVA, 3 Phase, 50Hz, Cast Resin Dry type, Dyn11, Air
Natural Cooled, Copper wound, With Off Load Tap Changer, Tap
range +5 to 5% in steps 2.5%, With OTI & WTI (Oil & Winding temp
indicator )
LT COMPARTMENT
Switchgears
Air circuit breaker, 4P, 433V, 1000A, 50kA, Microprocessor (Master
pack- MVS-ET2) based release, Fixed with (O/L,S/C,E/F) Protection,
Qty: 1No
Metering
Ammeter, Cl-1.0, Digital
Voltmeter, Cl-1.0, Digital
Switches
Ammeter selector, Voltmeter selector in built type,

gdmspl 71 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Indicating Lamps
Two sets, Make : Teknic/Vaishno
LT CTs
660V, Resin cast, 1000/5A, 5VA, Cl 1.0,
Enclosure - Sheet steel Thickness
2.0 mm for non-load bearing members , CRCA
2.0 mm for load bearing members, CRCA
100 X 50 , ISMC channel for base
Degree of Protection
IP53 for HT / LT Compartment
IP23 for Transformer compartment
Applicable standard
IEC : 62271-202
Interconnection
1R x 3c X 95 Sq mm HT XLPE CABLE between HT unit and
Transformer
Suitable cross section Aluminium bus bar between Transformer and
LT unit
Paint shade
Dark admiralty as per shade 632 of IS:5 for exterior, Ultra blue for
Canopy and Black for base frame, Pure polyester powder coated
Cable entry
HT & LT Power cables bottom side Each
26.5 315kVA PACKAGE TYPE SUBSTATION (For STP)
Supply, installation, testing and commissioning of 11KV/433V
package type outdoor substation consisting of following :
HT COMPARTMENT
Breaker

gdmspl 72 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Supply, Installation, Testing & Commissioning of 11kv, 21kA, SF6
insulated 3-way non extensible compact ring main unit comprising 2
nos of load break switches as incomer & outgoing of 630A with
integral earth switch, with neon live cable indicators and 1 no. of
vacuum or SF6 circuit breaker of 630A with integral earth switch, with
self powered over current and earth fault realy, with shunt trip coil of
230V AC, with push button for circuit breaker manual tripping, with
SF6 gas pressure monitor, pad locking facility with degree of IP67
protection. Make: Schnieder / ABB / C&S : 1No.

Current Transformer
660V, Resin cast, Single phase, 75/5A, 5VA, Cl-1.0, Qty-3Nos
Potential Transformer
11kV, Resin cast, Three phase, Ratio 11kV/110V, 50VA, Cl-1.0, ILV
12/28/75kV, VF 1.2 continuous, 1.9 for 8 Hours with HRC fuses on HT
LT side , Qty-1No
Metering
MFM, Cl-1.0, Digital, Model: EM6400, Qty : 1No
Indicating Lamps
One set, Make : Teknic/Vaishno
TRANSFORMER COMPARTMENT
Transformer
11kV/433V, 315kVA, 3 Phase, 50Hz, Cast Resin Dry type, Dyn11, Air
Natural Cooled, Copper wound, With Off Load Tap Changer, Tap
range +5 to 5% in steps 2.5%, With OTI & WTI (Oil & Winding temp
indicator )
LT COMPARTMENT
Switchgears
1 No. 160A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
2 Nos. 100A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
2 Nos. 63A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with
phase spreader & extended rotary handle
Metering
Ammeter, Cl-1.0, Digital

gdmspl 73 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Voltmeter, Cl-1.0, Digital
Switches
Ammeter selector, Voltmeter selector in built type,
Indicating Lamps
Two sets, Make : Teknic/Vaishno
LT CTs
660V, Resin cast, 160/5A, 5VA, and 100/5A, 5VA Cl 1.0,
Enclosure - Sheet steel Thickness
2.0 mm for non-load bearing members , CRCA
2.0 mm for load bearing members, CRCA
100 X 50 , ISMC channel for base
Degree of Protection
IP53 for HT / LT Compartment
IP23 for Transformer compartment
Applicable standard
IEC : 62271-202
Interconnection
1R x 3c X 95 Sq mm HT XLPE CABLE between HT unit and
Transformer
Suitable cross section Aluminium bus bar between Transformer and
LT unit
Paint shade
Dark admiralty as per shade 632 of IS:5 for exterior, Ultra blue for
Canopy and Black for base frame, Pure polyester powder coated
Cable entry
HT & LT Power cables bottom side Each
Total: Subhead 26
Subhead 27: STREET LIGHT FIXTURES
27.1 Supply of following type of prewired street light luminaires complete
with lamps, ballast, transformers, drivers as required of following
makes and models (or approved equivalent)
27.1.1 Type : LED Greenline Smart Luminaire with 25W Lamp
Make : Philips
Model No. : BRP020 1X10LED S1 HP/CW
Mounting Height : 4 M with 0.2M bracket
Wattage - 25 W

gdmspl 74 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Lamp Code - White
Maintenance Factor -0.80
Lumen Output - 1650 lms No.
27.1.2 Type : 20m Road NMV - LED Luminaire with 45W Lamp
Make : Philips
Model No. : BRP320 1X24LED-HP/CW PSU
Mounting Height : 6M with 0.5M bracket
Wattage - 45 W
Lamp Code - White
Maintenance Factor -0.80
Lumen Output - 3500 lms No.
27.1.3 Type : 20m Road Main -LED Luminaire with 72W Lamp
Make : Philips
Model No. : BRP410 LED CW072MRFGS1PSUGR
Mounting Height : 6M with 0.5M bracket
Wattage - 72 W
Lamp Code - White
Maintenance Factor -0.80
Lumen Output - 7000 lms No.
27.1.4 Type : 40M Road Main - LED Luminaire with 72W Lamp
Make : Philips
Model No. : BRP410 LED CW072MRFGS1PSUGR
Mounting Height : 8 M WITH 1m bracket
Wattage - 72 W
Lamp Code - White
Maintenance Factor -0.80
Lumen Output - 7000 lms No.
27.1.5 Type : 40M Road NMV+footpath - LED Luminaire with 72W Lamp
Make : Philips
Model No. : RP410 LED CW072MRFGS1PSUGR
Mounting Height : 7 M WITH 1m bracket
Wattage - 72 W
Lamp Code - White
Maintenance Factor -0.80
Lumen Output - 7000 lms No.
Total: Subhead 27

gdmspl 75 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Sub Head 28: PUMPING MACHINERY AND ALLIED EQUIPMENTS

28.1 HYDROPNEUMATIC SYSTEMS FOR RESIDENTIAL AND


ACADEMIC BLOCK
28.1.1 Supply, installing, testing and commissioning of clear water Factory
Fitted packaged hydropneumatic pumping system for general water
supply ( with variable frequency drive for each pump) as per following
details:
System Capacity
Maximum System Discharge : 60 M3/hr
System Pressure : 6.0 kg/cm2
The packaged unit shall be complete with :
a) Pumps: Vertical monoblock booster pumpset with mechanical seal
and VFD-

Main Pumps- 3 Nos. (each of 50% capacity)


Material of Construction (M.O.C):
Corrosion Resistant in general
: Casing Stainless Steel -AISI 304
: Impeller Stainless Steel -AISI 304
: Shaft Stainless Steel - AISI 316
: Pump Head Cast Iron/ Stainless
Steel - AISI 304
: Base Cast Iron
: Motor Stool Cast Iron

Motor: 2900 RPM; 3Ph 415V 50Hz


Insulation Class - F
Protection - IP54 Min.
b) Pressure Tank: FRP vessel with replacable polyetheruethane
(PEU) bladder certified for drinking water. Minimum 8 Bar pressure
rating 1No. of 200 to 250 Lts. Capacity.
c) Interconnecting Pipe work, Valves and Vibration Eliminators :
Common suction & delivery headers in Stainless Steel (Grade 304).
Isolating valves, non return valves and vibration eliminators on suction
& delivery sode of pumps.

gdmspl 76 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


d) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure transducers etc.
g) System Control Panel : The system control panel shall be factory
built and tested and shall have the following minimum features:

i) Fully protected, powder coated metallic housing.


ii) Complete switchgear, under/over voltage protection, single phase
preventors etc.
iii) VFDs for all the pumps
iv) Site programmable application optimised software
v) Integrated Modbus interface for BMS compatibility
vi) Large graphic display with as easy to use menu.
Programmable Control System shall be PLC based, duly authentiated Set
by the Pump Manufacturer.
28.2 WATER SUPPLY PUMPS AND CONTROL PANEL FROM WATER
RECEIVING STATION TO W.S.C.- I
28.2.1 Supply, installing, testing and commissioning of clear water pumps for
general water supply as per following details: ( Of Indigenous Make )

The pump unit shall be complete with :


Pumps: Horizontal monoblock booster pumpset with mechanical seal

Material of Construction (M.O.C):


Corrosion Resistant in general
: Casing Cast Iron
: Impeller Stainless Steel
: Shaft Carbon Steel
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - B Min
Protection - IP44 Min.
Duty:
Discharge : 30 M3/hr.
Working Head : 35 M Nos.

gdmspl 77 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


28.1.2.2 Supply, installation, testing and commissioning of electric pump
control panel metal clad cubicle type suitable for 415 V AC three
phase 4 wire 50Hz supply system. The panel shall be completely
compartmentalised and complete with relays, contactors, starters,
PLC logic and sequence controller Aluminium Bus Bars, designation
labels as per requirement, continuous earth bar, panel separators,
protective screens, cable clamping support system, top/bottom cable
gland plates for incoming and out going cable entries as per details
given below:

Programmable Control System for the following logic:


i) Pump I starts at set cut in pressure.
ii) Pump I stops if the cut out pressure is achieved otherwise Pump 2
starts if pressure keeps on falling.
iii) Pump 1 and Pump 2 stop the moment cut out pressure is
achieved.
iv) Pump 3 starts at set cut in pressure
v) Pump 3 stops if the cut out pressure is achieved otherwise Pump 2
starts if pressure keeps on falling.
vi) Pump 3 and Pump 2 stop the moment cut out pressure is
achieved.
vii) Pump I starts at set cut in pressure and so on.
The idea is to keep all the three pumps operational but with one
remaining standby at any particular moment.
Note: The start stop operation of the pumps shall be controlled with
pressure switches. Pressure switches and interconnecting control
cabling to be paid seperatly.
There shall be an audio visual alarm in case any pump fails to start.

INCOMING
100A TPN 25KA MCCB with rotary handle - 1 No.
BUSBARS
A set of 200 A 415V 50Hz 3 Phase four wire copper busbars.
INSTRUMENTS FOR INCOMER

gdmspl 78 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Ammeter 0-100A with Selector Switch
( including a set of CTs 100/5A)
Voltmeter 0-500V with selector switch.
A set of phase indicating light with
HRC fuses.
INSTRUMENTS ON OUTGOINGS
Analog Ammeter (0-30 A) Direct for each pump.
Indication lights for motor ON-OFF TRIP indicating lamps (RGA)
-03 nos. with control 6A SP MCB's for each pump
Selector switch (A/M) for auto/manual mode selection for the pumping
system
OUTGOING FEEDERS
For Pumps
32A 10KA TP MCB 7.5 HP star delta starter, overload relay, single
phase preventer, timer etc. - 3 Nos. Dry run protection with sensor
complete as required.
Note: Switchgear and starter ratings are indicative. The Tenderer shall Set
quote for the actual rating required as per the pump model proposed
by him.
28.3 SUMP DRAINAGE PUMP
28.3.1 Supply, installing, testing and commissioning drainage pumping
system in the sump of Under ground Pump Room comprising of the
following:
a) 2 Nos.Vertical fully floodable type submersible drainage pumps in
close coupled design single stage, suitable for handling minimum 12
mm dia solids.
Duty
Discharge of each pump : 300 LPM
Working Head : 16 M
Material of Construction (M.O.C):
Corrosion Resistant in general
: Bearings Anti friction,
prelubricated ball bearings,
packed with grease for life.

gdmspl 79 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Motor: Dry Motor with built in over
load protection
Protection - IP68.
Insulation Class - F
b) Electric control panel for automatic operation of pumps as per the
water level in the sump.The pump operation shall be controlled with
magnetic float type level controller.The Panel shall comprise of
incoming switch/MCB, voltmeter & ammeter, On-Off-Trip lamps,
starters with circuit breakers for each pump, single phase preventor
for three phase motors only for each starter, rotating start sequence,
both pumps to work simultaneously to meet peak flow
There shall be an audio-visual alarm, if any pump fails to start.

c) Power cabling and control cabling between magnetic float type


controller panel and pump panels.
d) Each pump should be skid base mounted of 9" height to avoid
mud choking.
e) Pump suspension systemwith Stainless Steel Sling wire with `U` Set
clamp.
28.4 WATER TREATMENT PLANT
28.4.1 Collection of water sample and getting it tested from reputed lab as Job
per IS:10500
28.4.2 Providing, installing, testing and commissioning vertical down flow No.
type multi grade sand bed pressure filter capable of filtering 35
cum/hour of water at prescribed filtration rate of 15 cum/sq.m./hr. The
filter shall comprise of MSRL shell, rubber lining thickness of
minimum 4mm, suitable for a test pressure of minimum 7.0
kg/sq.cm. , complete with mounting pedestals, manhole cover, PVC
filtering nozzles mounted on steel plate, 100 mm dia frontal piping
with butterfly valve, sampling arrangement, pressure guage, first
charge of filter media. etc. The vessel shall be suitably treated with
anti-corrosive paint and epoxy paint of approved shade externally

Filteration unit as described above having following parameters


Dia - 1750 MM
Height on Straight - 2000 MM

gdmspl 80 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Shell Thickness - 6MM
Dishend Thickness - 8MM
Rubberlining thickness - 4 MM (Min.)
Test Pressure - 7 Kg/cm2
Media Bed Depth - 1000MM
28.4.3 Providing, installing, testing and commissioning chlorine doser No.
comprising 100 litres capacity HDPE tank, electronic metering pump
of 0 - 6 litres/hr.capacity against the minimum line pressure of 3
kg/cm2 , injection fitting, solution delivery tube etc. including making
electrical connection including synchronisation for auto operation with
raw water feed pump, all complete.

28.4.4 Supplying, installing, testing and commissioning of horizontal / vertical


monoblock booster pumpsets as per following details: (Of Indigenous
Make)
The pump unit shall be complete with :
a) Pumps: Horizontal / vertical monoblock booster pumpset with
mechanical seal
a) Raw Water Feed Pumps 2W+1S
Discharge : 35 M3/Hr
Head : 15 m
Supply of
Fixing
Excavating
Constructing
Providing
Supplying
Material and &and
and
vitreous
trenches
fixing
installation
brick
grease
brick
fixing
ConstructionfixingPVC
masonry
china
masonry
in
of
Sand
mineral
M.S.
trapwaste
position
required
of 80electric
(M.O.C):half
Structural
Castopen
wool
pipework
xmanhole
stall
the
40
width
Iron control
preformed
surface
xmedium
lipped
Rain
work
Soil,
46
forcomprising
with
cm
pipes
panel,
drain
Waste
Water
fabricated
class
Urinal
(inside)
pipe
75cables,
with
cubical
Pipes
and
class
sectionsof
G.I.
ofbasin
UPVC
bricks
with
from
Vent
pipes
etc.
of
designation
type,
one
with
approved
including
standard
pipes
pipes
ofwith
'ROCK
made
class
brick
C.P.all
of
out of6brick
approved
min.
bricks
sections
designation
spreader
make
excavation
thick
fittings,
fittings
LLOYD'
Corrosion 14
in
conforming
kg./sq.cm.
and
specials
i.e.
brand
pipe,
cement
guage
make
masonry
for
Resistant75
rounds,
specials,
32
sockets
on
in
MS mortar
conforming
mm
&
pressure
cement
to
inpipes
sheet
solid
clamps
wall
C.P.
IS:1729
effecting
and
general 1of
angles,
with
stove
brass
:mortar
injection
dressing
5following
effecting
to(1
inlet
including
proper
enamelled,
trap
IS
cement
slotted
1and
moulded
:of
:anddiameters
4
proper
1729
connections,
sides,
outlet
angles,
(1
fittings
unions
: 5for cement
including
fine
and
ramming
connections,
drain
automatic
complete,
channels
and
including
sand)
fabricated
:earth
with
specials,
4fittings
of
R.C.C.
fine
operation
including
bricks
bottoms,
cast
painting
work
cutting
fittings
sand)
iron
and
top
i.e.
of
in
of the
specials,
and
slab
cutting
including
hangers
bends,
depth
class
chases
excavation
pipes specials
with
designation
with
upto
pumps
to
tees,
infor
i.e.
:1
earth
size,
walls
bitumastic
1.5
and
: support,
crosses,
bends,
Casing 2
like
in
drilling,
m
:4
excavation,
refilling
and
item
elbows,
75
including
mix
tees,
in
floors
boss
including
paint,
no.
(1
welding,
cement
Cast including
cement
crosses,
bends,
2.1
connections,
and
getting
10
wrapping
Iron complete
mortar
cutting
cm
fixing
making,
reducers
: painting
boss
out
2thick
coarse
and
pipe
1the
and
connections,
access
with
:including
bed
4welding
soil
threaded
pipes
sections
(1
making
sand
incoming
concrete
cement
aspieces,
with
required
to
painting
: 4good
with
tail
access
insert
graded
:two
switch,
adaptors
4
1pieces
Polythene
fine
:the
in
plates
with
coats
5pieces,
layers
sand)
10
stone
DOL/
walls
and
two
for
(1
of
in
star-delta
adaptors
caps
aggregate
RCC
cement
wherever
connections
not
plastered
coats
anti-corrosive
based exceeding
etc.
of
hessian
structural
:anti-corrosive
5
required.
jointing
12
for
starers,
20fine
to
mm
mm
paint
connections
cloth,
other
sand
20with
thick
nominal
members
automatic
and
binding
cm
:materials,
cement
paint
10
with
surrounding
in
size),
graded
to
on
with
with
as
switches,
depth
solvent,
other
buried
foundation
cleanouts,
1G.I.
directed
stone
: including
4with
wire
materials,
and
chasing,
(1
auxilary
aggregate
sand
cement
mesh
concealed
concrete
plugs,
by consolidating
150
cutting
switches,
Engineer-in-charge
of
cleanouts,
:reducers,
size
40
4mm
1pipework
coarse
:mm
and
424
all: pressure
8
G.x3/4",
nominal
making
around
cowls,
mix
plugs,
sand)
each
and (1
: Impeller Stainless Steel
switches,
reducers,
good
cement
including
size)
offsets,
deposited
finished
with
(external
stichingtwo
and
the:etc.with
coats
works):
walls,
425
cutting
ammeters,
cowls,
layer
coarse
in
mmG.I.
a enamel
floating
pipe
complete
bythick
and
wire
offsets,
sand
ramming,
ducts,
voltmeters,
cement
making
and
coat
paint
: in
8etc.
applying
all
sunken
graded
ofwatering
of
concrete
respects
good
in
neat
approved
phase
pipe
stone
floors,
cement
the etc.
ducts,
1including
indicators
:walls
aggregate
2quality
under
and :on
plaster
4sunken
(1
and
disposing
inside
testing
slung
and
cement
all40
floors
12complete
shade
and
floors,
mm
mm
from
ofof : complete
(for
2exposed
nominal
thick
surplus
coarse
over
ceiling
under
(The
pipe in
a
Contractor
slung
installation.
size)
hangers,
sand
including
excavated
surfaces
coat
two coats
of:inside
from :graded
primer
4 havingShaft
provision
supports,
(for
soil
ceiling
must
plastering
hot
as
ontwo
stone
submit
water
directed
exposed
including
of Stainless
clamps,
stone
all12
exposed
aggregate
the
clamps,
within
pipework.
baffle
mm ladders
100 Steel
Singlethick
apipes).
walls
mm
hangers,
lead
12.5Line
and
(Internal
with
thick
of
34.5
mm 50
lockable
Diagram
cement
concreting
and cm
nominal
MWork)
: jointing
deep covers
mortar
andsize)
and
allwith
Fabrication
around
for
third
for
1 refined
: water
filling
3onefor
(1
drawing
pipes
cement
storage
haunches
pig
19 cm
lead,indeep,
:tanks,
for
sunken
complete
3including
coarse
Consultant's
eachgrating
floors
40
sand)
in12all
mm
for
and
mmrespects
approval
finished
drains
thick
jointing
cement and
etc.).
including
with
before
with
plaster
45 acm refined
floating
supplying
long
1
painting
: 4embedded
pig
(1
coatcement
the
lead,
of ofexposed
panel).
neat
complete
:2.54cement
coarse
cm
pipes onin
Motor:
all respects
and
sand)
with
either making
two with
side 2900
coats ofRPM;
ainchannels
including
floating
brick enamel 3Ph
masonry,
coat
in of415V
painting
cement
paint neat
40of 50Hz
ofconcrete
mmcement
approved
exposed
thickinside 1100shade
:pipes
2 :xthe460and
with
mix
drain,
cmquality
(1
two
stone
cement
itscoats
topover
cover
and: of
2
a
enamel
coarse
exposed
coat
and 7.5
of primer,
sand
paint
cm side thick
: of
4including
etc.
Insulation graded
approved
bedClass concrete
stone
disposal
shade
- Baggregate
Min1 :of and
5 surplus
10quality(1cement
20 mm earth
overnominal
:acomplete
5 coat
finesize)sand
of primer,
as
neatly
: per
10
etc.
finished
standard
graded stone
complete
design aggregate
Protection with
as perF.P.S.
- IP44 40
design
bricks
mm
Min.:nominal: size) with 40 mm flooring in No.
cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded
stone aggregate 12.5 mm nominal size) with a floating coat of neat
cement including all earth excavation, refilling and disposal of
surplus earth complete as per standard design :

gdmspl 81 psda
plastered 12 mm thick with with 1 : 4 (1 cement : 4 coarse sand)
finished with a floating coat of neat cement on inside and exposed
surfaces having two stone baffle walls 34.5 cm deep and third one
19 cm deep, each 40 mm thick and 45 cm long embedded 2.5 cm on
SCHEDULE OF RATES
either side in brick masonry, 40 mm thick 100 x 60 cm stone cover
and 7.5 cm thick bed concrete 1 : 5 10 (1cement : 5 fine sand : 10
Items graded stone aggregate 40 Description
mm nominal size) with 40 mm flooring in Unit Quantity Rate Amount
cement concrete 1 : 2 : 4
28.4.5 Supply, installation, testing and ( 1 cement : 2 coarseofsand
commissioning : 4 graded
electric pump
control panel metal clad cubicle type suitable for 415V ACof three
stone aggregate 12.5 mm nominal size) with a floating coat neat
cement including all earth excavation,
phase 50Hz supply system. The panel shall be refilling and disposal of
completely
surplus earth complete
compartmentalised and as per standard
complete with design
relays, : contactors, starters,
sequential pump controller, Aluminum Bus Bars, designation labels as
per requirement, continuous Aluminium earth bar, panel separators,
protective screens, cable clamping support system, top/bottom cable
gland plates for incoming and out going cable entries as per details
given below:

Sequential pump controller is to keep all three pumps operational but


with one remaining standby at any particular moment.
Note: The start stops operation of the pumps shall be controled with
magnetic float type level sensors in the treated water tank. The
control cabling between sensors and the panel will be paid separately
as per the actual measurement under a separate item.
There shall be an audio visual alarm in case any pump fails to start.

INCOMING
63A FP 10 KA MCB - 1 No.
BUSBARS
A set of 63 A 415V 50Hz 3 Phase four wire copper busbars.
INSTRUMENTS FOR INCOMER
Ammeter 0-60A with Selector Switch
( including a set of CTs 60/5A)
Voltmeter 0-500V with selector switch.
A set of phase indicating light with
HRC fuses.
INSTRUMENTS ON OUTGOINGS
Ammeter with selector switch for each
pump.
Indication lights for ON-OFF-TRIP indication for each pump
Selector switch for auto/manual mode selection for the pumping
system
OUTGOING FEEDERS
For Pumps
Selector switch for (A/M) auto/manual operation - 01 no..

gdmspl 82 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


1 no. - 32A 10KA TP MCB 5 HP DOL starter, overload relay, single
phase preventer, timer etc. - 3 Nos. Dry run protection with sensor
complete as required.
Note: Switchgear and starter ratings are indicative. The Tenderer shall Set
quote for the actual rating required as per the pump model proposed
by him.
28.5 CABLING AND MAIN PANEL
28.5.1 Supplying and fixing of following types and sizes of 1.1 KV grade PVC
insulated conductor armoured cable conforming to IS : 1554.
28.5.1.1 3C 2.5 sq.mm. `Copper` conductor M
28.5.1.2 3C 4 sq.mm. Copper conductor M
28.5.1.3 4C 4 sq.mm. Copper conductor M
28.5.1.4 4 C 16 sq.mm. `Al' conductor M
28.5.1.5 3.5C 35 sq.mm. `Al' conductor M
28.5.2 Supplying, laying & terminating of following types and size of 1.1 KV
grade PVC isulated armoured control cables conforming to IS : 1554
Part-II
28.5.2.1 2C 1.5 sq.mm.Cu. Conductor M
28.5.2.2 3C 1.5 sq.mm.Cu. Conductor M
28.5.3 Supplying and making end termination with brass double compression
glands and copper/aluminium lugs for following size of PVC insulated
and PVC sheathed/XLPE copper/aluminium conductor cable of 1.1
KV grade as required :
28.5.3.1 3C 2.5 sq.mm. `Copper` conductor Set
28.5.3.2 3C 4 sq.mm. Copper conductor Set
28.5.3.3 4C 4 sq.mm. Copper conductor Set
28.5.3.4 4 C 16 sq.mm. `Al' conductor Set
28.5.3.5 3.5C 35 sq.mm. `Al' conductor Set
28.5.4 Providing and fixing following size G.I. strip / wire on surface or in
recess for body earthing of motors as required.
28.5.4.1 25x5 mm G.I. strip M
28.5.4.2 8 SWG dia. M

gdmspl 83 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


28.5.5 Supply, fabricating and installing following size of perforated M.S.
powder coated (of approved shade) (0.65 micron) cable trays
including horizontal and vertical bends, reducers, tees, cross
members and other accessories as required and duly suspended from
the ceiling with M.S. suspenders and including painting etc. as
required :

28.5.5.1 100 mm. width x 40 mm. depth x 1.6 mm. thickness M


28.5.5.2 150 mm. width x 50 mm. depth x 1.6 mm. thickness M
28.5.5.3 300 mm. width x 50 mm. depth x 1.6 mm. thickness M
28.5.6 Supply, installation, testing and commissioning of electric pump
control panel metal clad cubicle type suitable for 440V AC three
phase 50Hz supply system. The panel shall be completely
compartmentalised and complete with Aluminium Bus Bars,
designation labels as per requirement, continuous Aluminium earth
bar 40mm x 6 mm, panel separators, protective screens, cable
clamping support system, top/bottom cable gland plates for incoming
and out going cable entries as per details given below:

MAIN PANEL WATER PUMPING SYSTEM (IN W.S.C.)


INCOMER
160 A 25KA FP MCCB with phase spreader and extended rotary
handles - 1 No.
BUSBARS
A set of 315 A 415V 50Hz TPN 3 Ph 4 wire aluminium busbars. C./D.
1 Amp/ mm2.
INSTRUMENTS FOR INCOMER
A set of instrumentation with a set of Current transformer 160/5A with
Ammeter 0-160A, Selector Switch, Voltmeter 0-500V with selector
switch, a set of phase indicating lights with mcb fuses and energy
meter (KWH).
OUTGOING FEEDERS
25A FP 10KA MCB - 2 Nos.
32A FP 10KA MCB - 2 Nos.
63A FP 10 KA MCB - 2 No.
100A TPN 25KA MCCB with phase spreader and extended rotary Set
handle - 4 Nos.
28.6 PIPE WORK AND VALVES

gdmspl 84 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


28.6.1 Providing,fixing, jointing, testing and commissioning medium class
(Class B) G.I. Pipe work conforming to IS:1239 (Part I)-1990 for pipes
upto 150 mm dia.and MS pipe work conforming to IS:3589-1991 for
pipes above 150mm dia. with all fittings, flanges,specials & clamps
effecting proper connections, including painting with two coats of
epoxy paint of approved quality and shade over a coat of primer on
exposed pipework,complete in all respects : (Pipe work restricted
within the plant room for suction and delivery headers and delivery
pipe of submersible pumps)

28.6.1.1 150 mm dia pipe M


28.6.1.2 100 mm dia pipe M
28.6.1.3 80 mm dia pipe M
28.6.1.4 65 mm dia pipe M
28.6.1.5 50 mm dia pipe M
28.6.1.6 40 mm dia pipe M
28.6.2 Providing and fixing butterfly valve of approved make including a set
of MS flanges, required nos. of nut & bolts all complete and as per
following specification:
MOC:
Body - Cast Iron
Shaft - Carbon Steel / Stainless Steel
Body Liner - EPDM/ nitrile rubber
Disc - Epoxy coated C.I./ D.I.
28.6.2.1 150 mm dia ( with lever) (PN 16) Nos.
28.6.2.2 100 mm dia ( with lever) (PN 16) Nos.
28.6.2.3 80 mm dia ( with lever) (PN 16) Nos.
28.6.2.4 65 mm dia ( with lever) (PN 16) Nos.
28.6.2.5 50 mm dia ( with lever) (PN 16) Nos.
28.6.3 Providing and fixing Dual plate (Wafer type) check valve (non return
valve) of Class PN 16, having cast iron body, stainless steel disc
( AISI 316), trim and spring of approved make. including a set of MS
flanges, required nos. of nut & bolts all complete.
28.6.3.1 100 mm dia Nos.
28.6.3.2 80 mm dia Nos.
28.6.3.3 65 mm dia Nos.

gdmspl 85 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


28.6.4 Providing and fixing of flanged C.I (Pot) strainer on suction ends
submerged in water tanks, all complete.
28.6.4.1 250 mm dia Nos.
28.6.5 Providing and fixing of flanged end Pot/ Bucket type strainer in cast
iron body with stainless steel perforated sheet screen basket,
complete with drain plug.
28.6.5.1 65 mm dia Nos.
28.6.5.2 80 mm dia Nos.
28.6.6 Providing and fixing of nickel plated brass/ nonferrous alloy fullyway
ball valve ( minimum working pressure of 20 bar ) with operating
handle of approved make.
28.6.6.1 40 mm dia Nos.
28.6.6.2 32 mm dia Nos.
28.6.7 Providing and fixing heavy duty resilient rubber neoprene lined single
arch vibration eliminators suitable for raw water up to 70 deg.C
temperature, pressure upto 15 Bar and vacuum rating upto 700 mm
Hg.
28.6.7.1 100 mm dia Nos.
28.6.7.2 80 mm dia Nos.
28.6.8 Supplying, installation, setting, testing and commissioning of Nos.
differential type pressure switches of size 100 mm dia for operation of
pumps.
28.6.9 Supplying, installation, setting, testing and commissioning of pressure Nos.
gauge with isolation cock, all complete
28.6.10 Providing and fixing level indicator assembly for water tanks Set
comprising 2 nos. 15 mm dia gunmetal level guage isolation cocks
with screwed ends, heavy guage transparent polythelyne tube of upto
6.0 m length, 100 mm wide x 20 mm thick teak wood indicating board
painted with level indications in cms and litres, as required.

28.7 LEVEL CONTROLLERS IN OVERHEAD TANKS

gdmspl 86 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


28.7.1 Supplying, fixing and commissioning of magnetic float type automatic Set
level controller comprising of magnetic float type level sensors of
Stainless Steel (Grade 304) construction (low & high level sensing
in over head water tank) and level control unit with manual overide
facility in a weather proof enclosure (Minimum IP 65 Rating) for auto
opening and closing of solenoid valves, including control cabling
between sensor, controller and solenoid valves etc, all complete.

28.7.2 Providing, fixing, wiring and commissioning Solenoid Valves as per


following sizes
28.7.2.1 15 mm dia (ND) Nos.
28.7.2.2 20 mm dia (ND) Nos.
28.7.3 Providing, fixing, wiring and commissioning Motorised Valves as per
following sizes
28.7.3.1 40 mm dia (ND) Nos.
28.7.3.2 50 mm dia (ND) Nos.
28.7.4 Providing, fixing, testing and commissioning of motorised valve
byepass arrangement with two nos. full bore ball valves/ Butterfly
valves including taping the G.I main of upto 65 mm dia (Tees with
plugs already provided in the main), fixing neccassary fittings like
tees, elbows, unions and nipples etc, complete as required.
28.7.4.1 15 mm dia (ND) Nos.
28.7.4.2 20 mm dia (ND) Nos.
28.7.4.3 40 mm dia (ND) Nos.
28.7.4.4 50 mm dia (ND) Nos.
28.8 RECYCLED WATER SUPPLY ZONE
28.8.1 HYDROPNEUMATIC SYSTEMS FOR TREATED EFFLUENT
TRANSFER TO RESIDENTIAL AND ACADEMIC BLOCK
28.8.1.1 Supply, installing, testing and commissioning of clear water Factory
Fitted packaged hydropneumatic pumping system for general water
supply ( with variable frequency drive for each pump) as per following
details:
System Capacity
Maximum System Discharge : 30 M3/hr
System Pressure : 6.0 kg/cm2
The packaged unit shall be complete with :

gdmspl 87 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


a) Pumps: Vertical monoblock booster pumpset with mechanical seal
and VFD-

Main Pumps- 3 Nos. (each of 50% capacity)

Material of Construction (M.O.C):


Corrosion Resistant in general
: Casing Stainless Steel -AISI 304
: Impeller Stainless Steel -AISI 304
: Shaft Stainless Steel - AISI 316
: Pump Head Cast Iron/ Stainless
Steel - AISI 304
: Base Cast Iron
: Motor Stool Cast Iron
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Protection - IP54 Min.
b) Pressure Tank: FRP vessel with replacable polyetheruethane
(PEU) bladder certified for drinking water. Minimum 8 Bar pressure
rating 1No. of 200 to 250 Lts. Capacity.
c) Interconnecting Pipe work, Valves and Vibration Eliminators :
Common suction & delivery headers in Stainless Steel (Grade 304).
Isolating valves, non return valves and vibration eliminators on suction
& delivery sode of pumps.
d) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure transducers etc.
g) System Control Panel : The system control panel shall be factory
built and tested and shall have the following minimum features:

i) Fully protected, powder coated metallic housing.


ii) Complete switchgear, under/over voltage protection, single phase
preventors etc.
iii) VFDs for all the pumps
iv) Site programmable application optimised software
v) Integrated Modbus interface for BMS compatibility

gdmspl 88 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


vi) Large graphic display with as easy to use menu.
Programmable Control System shall be PLC based, duly authentiated Set
by the Pump Manufacturer.
28.8.2 TREATED EFFLUENT TREATMENT
28.2.2.1 Supply, installing, testing and commissioning of treated effluent feed
pumps as per following details:
The pump unit shall be complete with :
a) Pumps: Horizontal monoblock booster pumpset with mechanical
seal
Material of Construction (M.O.C):
Corrosion Resistant in general
: Casing Cast Iron
: Impeller Stainless Steel
: Shaft Carbon Steel
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - B Min
Protection - IP44 Min.
Duty:
Discharge : 30.0 M3/hr.
Working Head : 18 M Nos.
28.8.2.2 Providing, installing, testing and commissioning Disc Filter as per
following details
Details of Equipment
Rating : 50 Micron
Flow rate : 30 M3/hr.
Size : 2 inch
Housing Material : Polyproplene Unit

gdmspl 89 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


28.8.2.3 Providing, installing, testing and commissioning of Ultra Filtration Job
(UF) system for further polishing treated effluent and capable of
producing 30,000 litre / hour of polished water meeting the
requirements given in Section-B & D of Scope of Work. The system
shall be complete with UF Feed Pumps (1W+1S), CIP Pumps
(1W+1S), Backwash Pumps (1W+1S), Cartridge Filters, UF
Membranes Flushing / Cleaning System, complete instrumentation for
automation and monitoring, Rotameters, Pressure Gauges,
interconnecting pipework, electrical cabling and switchgear, all
complete as described in Scope of Work enclosed herewith.
Note: The process and the control system of Ultra Filtration (UF)
Package shall be in complete conformity of the UF Membrane
Manufacturer

28.8.2.4 Supplying, installing, testing and commissioning of Submersible


drainage pumps as per following details: (for plant room drainage )
a) Pumps: Non-clog fully floodable submersible pump suitable to
minimum 12 mm solid handling capacity
Starter for the pumps will be in Main panel
Material of construction ( M.O.C)
Corrosion Resistant in general pump housing- Stainless Steel
304 AISI Impeller- Stainless Steel 304 AISI Shaft -
Stainless Steel 304 AISI
Motor:
Housing Stainless Steel
RPM 2900
Insulation Class F
Protection Degree IP68
Suspension System
Duty:
Discharge : 300 LPM.
Head : 16 M Nos.
28.8.2.5 Supplying, installing, testing and commissioning of following water
quality monitring devices.
Online digital pH indicator Nos.
28.8.2.6 Providing hardness testing kit with reagents No.

gdmspl 90 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


28.8.2.7 Providing, fixing, testing and commissioningof Electro Magnetic Flow
Transmeter with Communication Port, of approved makes.
Suitability: Sewage Effluent
MOC:
Body : Non-corrosive
Lining : PTFE
Flanges : Stainless Steel
Electrode : Stainless Steel
Coil Housing : Stainless Steel
Pressure Rating : Minimum 10 Bar
Temerature Withstanding : upto 850 C
Display: LCD showing both flow rate and totalised flow
Communication Port: RS 485
100 mm dia No.
Total : Sub Head No. 28
Sub Head 29: SEWAGE TEATMENT PLANT
29.1 Supplying, placing and commissioning the materials and components Job
for the natural process based sewage treatment system. This scope
includes supply, installing, testing and commisioning of all media,
gravel, soil, enzymes, microbial solutions, plantation etc.

29.2 PLANT AND EQUIPMENT FOR TERTIARY TREATMENT


29.2.1 Supplying, installing, testing and commissioning of Submersible
tertiary treatment feed pumps (common for MGF & ACF) as per
following details: (for plant room drainage)
a) Pumps: Non-clog fully floodable submersible pump suitable to
minimum 12 mm solid handling capacity
Starter for the pumps will be in Main panel ( Item no. 2.10)
Material of construction ( M.O.C)
Corrosion Resistant in general
pump housing- Stainless Steel 304 AISI
Impeller- Stainless Steel 304 AISI
Shaft - Stainless Steel 304 AISI
Motor:
Housing Stainless Steel
RPM 2900

gdmspl 91 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Insulation Class F
Protection Degree IP68
Suspension System
Duty:
Discharge : 25 cum./hour
Head : 30 M Nos.
29.2.2 Providing, installing, testing and commissioning vertical down flow
type multi grade sand bed pressure filter capable of filtering 25
cum/hour of water at prescribed filtration rate of 15 cum/sq.m./hr. The
filter shall comprise of MSRL shell, rubber lining thickness of
minimum 4mm, suitable for a test pressure of minimum 7.0
kg/sq.cm. , complete with mounting pedestals, manhole cover, PVC
filtering nozzles mounted on steel plate, 100 mm dia frontal piping
with butterfly valve, sampling arrangement, pressure guage, first
charge of filter media. etc. The vessel shall be suitably treated with
anti-corrosive paint and epoxy paint of approved shade externally

Filteration unit as described above having following parameters


Dia - 1500 MM
Height on Straight - 2000 MM
Shell Thickness - 6MM
Dishend Thickness - 8MM
Rubberlining thickness - 4 MM (Min.)
Test Pressure - 7Kg/cm2
Media Bed Depth - 1000MM No.
29.2.3 Providing, installing, testing and commissioning vertical down flow
type activated carbon filter capable of filtering 25 cum/hour of water
at prescribed filtration rate of 15 cum/sq.m./hr. The filter shall
comprise of MSRL shell, rubber lining thickness of minimum 4mm,
suitable for a test pressure of minimum 7.0 kg/sq.cm. , complete with
mounting pedestals, manhole cover, PVC filtering nozzles mounted
on steel plate, 100 mm dia frontal piping with butterfly valve,
sampling arrangement, pressure guage, first charge of filter media.
etc. The vessel shall be suitably treated with anti-corrosive paint and
epoxy paint of approved shade externally

gdmspl 92 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Filteration unit as described above having following parameters
Dia - 1500 MM
Height on Straight - 2000 MM
Shell Thickness - 6MM
Dishend Thickness - 8MM
Rubberlining thickness - 4 MM (Min.)
Test Pressure - 7Kg/cm2
Media Bed Depth - 1000MM No.
29.2.4 Providing, installing, testing and commissioning chemical doser Nos.
comprising 100 litres capacity HDPE tank, electronic metering pump
of 0 - 6 litres/hr. capacity injection fitting, solution delivery tube etc.
including making electrical connection for auto operation, all
complete.
29.2.5 Providing, installing, testing and commissioning UV Disinfection
System for the complete disinfection of the final effluent of the
following make or equal approved.
Flow : 25.0 M3/Hr
Make: Alfa UV No.
29.2.6 Supply, installing, testing and commissioning of treated effluent
transfer pumps (from STP to W.S.C.-II) as per following details:
The packaged unit shall be complete with :
Pumps: Mono block pumps suitable to handle waste water with
mechanical seal -
2 nos. (1 working+1 standby)
Material of Construction (M.O.C):
Corrosion Resistant in general
: Casing Cast Iron
: Impeller Cast Iron/
Stainless Steel 304 AISI
: Shaft Carbon Steel
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Protection - IP54 Min.
Duty:
Discharge (each pump) : 30 M3/Hour
Head : 35 M Nos.

gdmspl 93 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


29.2.7 Providing, fixing, jointing, testing and commisioning interconnecting Lot
pipe work, valves, pressure gauges with isolating cocks etc.

29.2.8 Providing, fixing, connecting, testing and commisioning power and Lot
control cabling between electric control panel, pumps, level sensors
& controllers, solenoid valves, etc. including cable trays, race ways,
conduits etc.
29.2.9 Supply, installation, testing and commissioning of Electric Control
Panel metal clad cubicle type suitable for 415V AC three phase 50Hz
supply system. The panel shall be section wise compartmentalised
and complete with relays, contactors, starters, sequential pump
controllers, Aluminum Bus Bars, designation labels as per
requirement, continuous earth bar, panel separators, protective
screens, cable clamping support system, top/bottom cable gland
plates for incoming and out going cable entries, ar required.

Note: Sequential controller for each set of pumps is to keep all three No.
pumps operational but with one remaining standby at any particular
moment.
29.2.10 Supplying, installing, testing and commissioning of following water Nos.
quality monitring devices.
Online digital pH indicator
29.2.11 Providing hardness testing kit with reagents No.
29.2.12 Providing, fixing, testing and commissioningof Electro Magnetic Flow
Transmeter with Communication Port, of approved makes.
Suitability: Sewage Effluent
MOC:
Body : Non-corrosive
Lining : PTFE
Flanges : Stainless Steel
Electrode : Stainless Steel
Coil Housing : Stainless Steel
Pressure Rating : Minimum 10 Bar
Temerature Withstanding : upto 850 C
Display: LCD showing both flow rate and totalised flow
Communication Port: RS 485

gdmspl 94 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


29.2.12.1 80 mm dia Nos.
29.2.12.2 100 mm dia Nos.
Total : Sub Head No. 29
Sub Head 30 : FIRE FIGHTING INSTALLATION
30.1 HYDRANT SYSTEM
30.1.1 CONDENSER WATER PIPE
Supplying, fixing, testing and commissioning of condenser water
pipes of following sizes of MS 'C' class along with necessary clamps,
vibration isolators and fittings such as bends,tees etc.but excluding
valves, strainers, gauges etc. adequately supported on rigid supports
duly painted/buried in ground excavation and refilling etc. as per
specification and as required complete in all respect.

Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS
: 1239 and pipes size above 150mm shall be welded black steel pipe
heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet
for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet
for pipes of 400 mm dia and above.
Pipe work for Internal / Exposed Hydrant System
100mm dia. M
30.1.2 Providing, laying, jointing, testing and commissioning pipe work for
Internal / Exposed Hydrant System including fixing of pipe work on
walls, beams, slabs, columns etc. with M. S. supports (duly painted),
adjustable hangers, complete in all respects.
Material: M.S pipe Class 'C' conforming to IS:1239 for pipes upto
150 mm dia and IS:3589-1991 for pipes above 150 mm dia.
Fittings: UL and FM approved ductile iron Fittings Upto 50 mm dia
pipes suitable for threaded joints ; Heavy Class MS fittings for pipes
above 50 mm dia suitable for butt welding and flanged joints.
Painting: Pipe work shall be painting with two coats of enamel paint of
fire red shade over a coat of primer.
30.1.2.1 80 mm dia pipe M
30.1.2.2 50 mm dia pipe M
30.1.2.3 25 mm dia pipe M
30.1.3 Supplying, fixing, testing and commissioning of following valves,
gauges and strainers for condenser water circulation as per
specifications.

gdmspl 95 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet &
O - ring & PN 16 pressure rating as specified.
30.1.3.1 100mm dia. Nos.
30.1.4 NON - RETURN VALVE with dual plate of C I body SS plates
vulcanized NBR seal flanged end & PN 16 pressure rating as
specified.
30.1.4.1 100mm dia. Nos.
30.1.5 Providing and fixing of nickel plated brass/ nonferrous alloy fullyway
ball valve ( minimum working pressure of 20 bar ) with operating
handle as per specification and of approved make.
30.1.5.1 25 mm dia. No.
30.1.6 Providing and fixing stainless steel (grade AISI 304) single headed No.
landing valve (hydrant) conforming to IS : 5290 - 1993 with 63 mm
female instantaneous outlet connection with blank caps and chains
conforming to IS: 903 all complete
30.1.7 Providing and fixing impact, abrasion and weathering resistant No.
rubberised fabric lined (RRL) hose pipe conforming to IS : 636-1979
(Type -2) of 63 mm dia and 15 m length with stainless steel (grade
AISI 304) instantaneous male and female couplings conforming to IS:
903-1975.
30.1.8 Providing and fixing Controlled Percolating (CP) Hose ISI marked No.
(IS:8423) 63 mm dia x 15 m long complete with instantaneous type
stainless steel (grade AISI 304) 63 mm dia, ISI marked Male &
Female couplings (IS:903) bound and riveted to hose pipe with
copper rivets and 1.5 mm copper wire. (For external hydrants)
30.1.9 Providing and fixing in position the industrial type pressure gauges Nos..
with gun metal / brass valves complete as required
30.1.10 Providing and fixing swinging type first aid fire hose reel comprising No.
20 mm dia 36 m long thermoplastic reinforced hose reel tubing
conforming to IS :12585 Type-2, MS drum with fixing bracket
conforming to IS:884 and with 5 mm dia stainless steel (grade AISI
304) shut off nozzle conforming to IS:8090, all complete

30.1.11 Providing and fixing stainless steel (grade AISI 304) branch pipe No.
nozzle conforming to IS : 903, suitable for instantaneous connections
to hose coupling etc. as required:

gdmspl 96 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


30.1.12 Providing and fixing standard Fireman's Axe with heavy insulated No.
rubber handle.
30.1.13 Providing, fabricating and fixing single/ double leaf door with frame
only for all internal fire hydrants fabricated from MS sections, welded
construction, having glazed panels with reinforced glass, integral
three point locking arrangement, stove enamelled fire red finish with
"FIRE HOSE" written on front, suitable to house two nos.15m lengths
of canvas hose with couplings, 1 no. branch pipe and 1 no. first aid
fire hose reel along with the landing valve all complete.

Size 1300x950 mm ( approximate) No.


30.1.14 Providing and fixing weather proof outdoor type hose cabinet made of No.
not less than 1.5 mm CRCA MS sheet having glazed door, locking
arrangement, painted with two coats of enamel paint over a coat of
primer and of size suitable to accomodate yard hydrant, two nos. 15
m lengths of 63 mm dia RRL hose pipe and branch pipe.
Minimum Size 900 x 600 x 350 mm

30.1.15 Providing, fixing and testing forged brass 25 mm dia screwed inlet No.
single acting air release valve with 25 mm dia ball valve on inlet side
and pressure gauge with isolating cock.
30.2 FIRE PUMPS & CONTROL PANELS
NOTES :
1) Pumps shall be capable of furnishing not less than 150% of rated
capacity at a head of not less than 65% of the rated head. The shut
off head shall not exceed 120% of rated head.
2) Valves on suction and delivery sides shall be paid seperately as
per relevant items in other subheads.
30.2.1 Supply, installing, testing and commissioning of clear water packaged
Fire Fighting Pumping System at Terrace Level ( fixed speed type) as
per following details:
The packaged unit shall be complete with :
a) Pumps: Horizontal / vertical monoblock booster pumpset with
mechanical seal -
1 no.

gdmspl 97 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


Material of Construction (M.O.C):
Corrosion Resistant in general
: Casing Cast Iron
: Impeller Stainless Steel
: Shaft Stainless Steel
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Protection - IP54 Min.
Duty:
b) Interconnecting Pipe work, Valves and Vibration Eliminators :
Common suction & delivery headers in G.I (Heavy Class ), `Y`
Strainer, Isolating valves, non return valves and vibration eliminators
on suction & delivery side of pumps.
c) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure switches etc.
g) Electric control panel, cubical type, made out of 14 guage MS
sheet stove enamelled, for automatic/manual/remote operation of the
fire pump above. Control panel (to be installed at terrace near the
pump) with incoming 63A TPN switch disconnector, DOL automatic
pressure switch operated starters with push buttons for manual over
ride, control wiring, ammeter, voltmeter, phase indicators, Remote
Panel with push buttons for manual operation (the remote panel shall
be located at ground level) all complete (The Contractor must submit
the Single Line Diagram and Fabrication drawing for Consultant's
approval before supplying the panel).

h) Shade: The entire package including pump, skid, interconnecting


piping shal be finished in Fire Red Colour.
30.2.1.1 Discharge : 900 LPM
Head : 35 M SET
30.2.2 Providing and fixing Cast Iron sluice valve with hand wheel, having
rising stem (OS & Y Type) complete with bolts, nuts, rubber insertions
etc. all complete (as per IS:14846)
30.2.2.1 100 mm dia No.

gdmspl 98 psda
SCHEDULE OF RATES

Items Description Unit Quantity Rate Amount


30.2.3 Providing and fixing mechanical locking of sluice/ butterfly valve with No.
leather strap and pad lock complete
Total : Sub Head No. 30