Multi Timer
function Timer
DIN W48 x H48mm, Solid-State, Multi
=\Features
Realization of wide range of power supply
24-240VAC 50/60Hz / 24—240VDC 12VDC
Various output operation (6 kinds mode:
‘Multi time range (16 kinds of time range)
@Wide control time (0.
Easy setting of time, lime range, output operation mode
eBuilt—in LED indicator:
Ay tinin Store une
Ordering information
for output status
AT 8 N AT|| 11] [DN
3 2 (it [i in oua tyne
nn] START
“ 7°) instaneous contact DPDT (Ie) by Teme lit DPOT (Ze) stantaneous contact SPDT (1c
bel Maltunction ‘Smm amplitude at frequency of 10 iz in each of X, Y, Z directions for 10 minutes
opval Ce Ws *.
‘Auton 2-38ATN Series
™Connections
ATEN
*IAl. IF] mode #(A1], (B), (FI), [1] mode
:
1 9 ES LOAD
A
(Dimensions
eracke os Panel cut-out
o— ity
T t
:
nn Min 62 wit
mi
I
I
Penet (Unit:mm)
B-39 AutonicsMulti Timer
‘Front panel identification
Output
Time limit output operation{ON) : Light on
Operation mose display
Time range disalay
ATS
‘A, AI, B, F, FI, I mose)
range selector
(Changing tho time
unit per 4 revolutions)
sri Ron Se ATHDN/ATIIEN
A, F, FA, C, D, I mo
Time unit}
Operation mode
(see, min, hour, 10h)
Please rotate the time range switch and operation mode switch to CW (Clockwise) direction,
Time specifications
Time range Time unit Time setting range
05 0.05-0.5
10 sec 011.0
5 05-5
io 10
os 005-05
70 min 1-10
5 O55
10 =o
os T05-05
72 01-10
: hour Tes
To eal)
os 005-05
10 01-10,
5 10h O55
10 1=10
‘Output operation mode of each model
@AT8N @ATIIDN/ATIIEN
Display] Output operation mode Display] Output operation mode
A POWER ON DELAY A (GNAL ON DELAY
At POWER ON DELAY 1 F FLICKER (OFF START)
B POWER ON DELAY 2 FI FLICKER 1 (ON START)
F FLICKER (OFF START) ce SIGNAL OFF DELAY
FA FLICKER 1 (ON START) D SIGNAL ON/OFF DELAY
I INTERVAL 1 INTERVAL
Autonics 8-40ATN Series
‘=\Output operation mode(AT8N)
Setting time, 12 tr.
Al:Return time(Max. 100s}
Mode
POWER ON
DELAY MODE
POWER ON
DELAY 1 MODE,
(One-shot
output)
POWER ON
DELAY 2 MODE
FLICKER MODE
FLICKER 1
MODE
INTERVAL
MODE
‘ime tmit contact NO. 1-4
Instantaneous contact NO 1-3
ee)
eratonfpower LED
Time tit contact NC
Instantaneous contact NC 1-4
Instantanooue contact NO 1-3
Time fmt output operation LED
Time tit contact NC B=
Instantaneous contact NC 1-4
Instantanooue contact NO 1-2
“me fmt output operation LED
Ime tnt contact NO. 1=3
“ime bmi
Instantaneous contact NC +
Instantanoous contact NO 1-3
Instantaneous contact NC T=
Instantaneous contact NO 1-2
Time limit output operation LED
peraton/oomer LED
Time chart
When using FF
Please set the
‘output operation modes, ifthe time Is set too shor, the output may not work properly
ime at Teast over 100ms,
AutonicsMulti Timer
=|Output operation mode(AT11DN/AT11EN)
Mode Time chart
SIGNAL AESET 27
ON DELAY MoDE Te tonite
vant 2
FLICKER RESET 2-7
MODE Time mt cotet NO
Tio mou opeeion ED —
Opwatonfoowe! LED
FLICKERT ne
MODE ‘Time limit contact NO
stant
wert
SIGNAL
OFF DELAY Tine tnt conan NC
MODE tnt entct NO [
SIGNAL ON 7
JOFF DELAY Time tn contact NC
bet me Int contact NO
INTERVAL sie ine
MODE ‘Time limit contact NO L_
Tie mou pean LED —
Operant LED
Note). If power is removed or the RESET terminal is shortcircuited, the timer will be reset
2. 1f the INHIBIT terminalis short-circuited during a timing cycle, the time will stop.
3, When using F, FI output operation mod
Please set the time at least over L00ms,
1 time is set too short, the output may not work praperly
‘AutonATN Series
Proper usage
Repeat function(Flicker)
Able to use one AT Timer for 3 Sub Relays and
2 Timers (Plicker function)
Simple to use
eswiteh A
licker function with only one AV
Start, Switch B: Reset
Wares
“4 GO)
al input
It is able to use voltage output type as input
signal source instead of open collector output in
id~state circuit (Proximity sensor, Photo~
electric sensor) whieh has range of 10-30VDC
output voltage
When H signal change to L,
When transistor(Q) is ON st
residual voltage under 0.5
Timer will start
tus, please make
10-0v06
GINTERVAL mode
Able to make Instantaneous ON and T
me limit
(Self—holding circuit) with using INTERVAL mode.
OTerminal connection
DPlease wire correctly with wiring instructions
Connect the power line without observing
polarity for ATN series AC power type, but
please be aware of power connection for DC
power type.
Te Timer Te TimariaTa
x “| renee
aw INTERVAL modo >
‘Glnput signal condition(ATI1DN, ATITEN)
1. Relay contact input
Please use gold=p
Led switches with good contact
bouncing time for contact
input. (pen resistance:Over 100k®, Short
resistance:Underlk 2)
wPlease use a contact that can function reliably
at BVDC 0.4mA.
2. NPN open collector transistor input
circuit
Please use the characteristic of transistor as follow:
Veco : Min. 25V
Min, 10mA.
iebo : Max. 0.2uh
Residual voltage
Max. 0.59
Power supply] __8Pin Type
AC Type | Terminal @ -
Se type) Terminal D+
When turning off the power, be aware of inductive
voltage. (If using power line with another high
voltage line or eneray line near by, it may cause
inductive volta
Power ripple should be un and power
supply should be within range of allowable voltage
for DC power type,
Please supply the power quickly when using a
switeh or a relay contact. Otherwise it may cause
time error or power reset failure
3) The load of Control output should be under rated
load capacity.
Autonics:OSetting time
Do not chang
ime range, Operation mode
1e range or operation mode while
time operating, When changing it, please power off
or apply reset signal.
input connection
DATIDN/ATLIEN Timer is transformer-less
typ
“ting relay contact for input signal and transistor,
therefore please check following for connec
Fig. 1) ATHDNIATITEN
“Sensor?
2)When using the terminal @ as a common terminal
of input signal as (Pig. 2
t may cause damage to
che inner circuit of ATLIDN/ATLIBN, please use
che terminal @ for common terminal as (Fig. 3)
Fig. 2) ia. 3)
Nott Into
Potty
Power
‘more than one timer with one contact,
or transistor input, the short current is flowed
when it is connected as (Fig. 4). Please connect
the power phase correctly as (Fig. 5) correctly.
‘Be Bie
AVInhibit, Start, Reset signal applied by short—
ircuting input terminal @-®, @-@ or @-C.
it may cause internal circuit damaged by wrong
5)Ié using power line with another high voltage line
or energy line at the same conduit, it may cause
inductive voltage. Therefore please use seperated
conduit for power line.
6)When input (Start, Reset, Inhibit) wire is long,
plese use shielded wire and it should be shor
Autonics:
Multi Timer
Common
1)If operating the unit in high temperature, it may
cause damage to internal components Electrolytic
Condenser ete)
2)Please use it as
ig. 7) in order not to flow
leakage current into timer
Fa. 6) Fo
Power
Pow
3)Environment
Please avoid the following places:
Where this product may be damaged by strong
impact or vibration,
eWhere corrosive &
water, oil, dust exist.
Where magnetic and electrical noise occ
ou
or flammable gas and
jere there are high temperature and humidity
beyond rated specification.
Where there are strong alkalis and acids.
eWhere there are direct rays of sun,