Anda di halaman 1dari 46

TUV

SUD
IS0 9001
NASA FIRE TECHNOLOGY LIMITED

FIRE SAFETY PRODUCTS & SOLUTIONS

Proudly Made in India


NASA FIRE TECHNOLOGY LIMITED 1
TUV
SUD
IS0 9001

NASA FIRE TECHNOLOGY LIMITED 2


index

who we are 5

product overview

nasa semi-automatic 8 - 11

nasa automatic 12 - 13

nasa ire suppression systems 14 - 15

nasa mini ire tender 16 - 19

nasa spill handling kit 20 - 21

nasa lame retardant chemical granules 22 - 23

nasa product gallery 24 - 25

characteristics of extinguishing media used 26 - 27

technical details of all products 28 - 35

technical comparison of nasa semi-automatic 36 - 37

with conventional ire extinguishers

select customer testimonials* 38 - 41

frequently asked questions 42 - 43

certiications 44

* (Partial list)

NASA FIRE TECHNOLOGY LIMITED 3


Years of innovation, research and development, and 18 iterations of product design have given us a product that
is the best in the world, and proudly designed and made in India.

Dr. H. S. Purohit
Managing Director

NASA FIRE TECHNOLOGY LIMITED 4


who we are

Novel Access of Scientists Aspiration

We are a team of engineers with a mission to bring a complete revolution


in the world of ire safety by offering sustainable ire safety solutions. In
order to accomplish our mission, we need to provide proactive means for the
community through:

1) Education: To showcase and educate how ire can be avoided with a better
understanding of the ire chemistry - a triangle

2) Invention: Keeping in mind numerous limitations faced by century old


conventional ire extinguishing technology, reliable ire safety equipments
and systems have been invented by NASA Fire Technology Limited for the
irst time in the world to satisfy a long awaited need for true ire safety.

NASA Fire Technology Limited designs and develops various clean gas
products, systems and accessories for ire prevention and safety. We have
also designed some very eficient lame retardant chemical granules for
specialized ire safety applications. Our team has dedicated 30 years to
researching and conducting in-depth studies on working conditions and
human psychology to revolutionize the ire safety industry.

Unlike other extinguishers, our stainless steel devices are leak proof and
maintenance free. Our ire detecting and extinguishing devices provide a
safer environment for everyone and have also drastically reduced inancial
losses of our customers. NASA wants Fire and Accident to become history
by eliminating all chances of Fire or Accidents taking place due to incorrect
practices, lack of awareness or acts of negligence.

NASA strongly opposes the use of the word Fire Fighting and appeals to
everyone to believe in taking preventive action rather than curative one. After
all, Fire is GOD and GOD cannot be fought with. But surely, we can prevent
his curse. This is what he constantly conveys and prays during all NASA
Seminars and Workshops.

Not A Single Accident

NASA FIRE TECHNOLOGY LIMITED 5


who we are

leave outdated technology in the dust...


no more injuries, no more weightlifting...
NASA FIRE TECHNOLOGY LIMITED 6
introducing hi-tech and superior
fire safety products & solutions
for a safer world
NASA FIRE TECHNOLOGY LIMITED 7
nasa semi-automatic

NASA believes in not compromising at any level. It took 30+ years of intensive
research to develop a unique, hi-tech and intelligent Fire Extinguisher, which
has been a long awaited need of the industry. Approved by one of the best
certifying agencies in the world, Underwriters Laboratory (UL) and Bureau
of Indian Standards (BIS), UL Listed NASA 227 MAR and BIS Listed (ISI)
NASA 200 MAR respectively have been appreciated by every user in terms
of performance and reliability. Suitable for all classes A,B and C of ire,
corrosion free and maintenance free ire extinguisher, it comes with a gas
shelf life of 10 years. The unique leak proof valve design is the best in TUV
SUD
the world, and is patent pending. Furthermore, this extinguisher can be IS0 9001

used multiple times until the last drop, while other extinguishers have many
limitations.

decade experience - it does not leak UL approved pressure gauge specially unique design: discharges intelligently
designed for NASA products

lock-pin design: does not jam unique ring: protects the extinguisher

SEMI-AUTOMATIC WITH UL LISTED NS_123 CLEAN GAS

Product Code Model Capacity (kg) Gross Weight (kg) Listing

NS_227 NASA 227 MAR 2.27 4.4 UL

NS_200 NASA 200 MAR 2.00 4.1 BIS (ISI)

NS_400 NASA 400 MAR 4.00 7.5 -

NS_600 NASA 600 MAR 6.00 10.0 -


NASA 227 MAR
NMNS_227 2.27 4.4 -
NON-MAGNETIC
NASA 200 MAR
NMNS_200 2.00 4.1 -
NON-MAGNETIC

NASA FIRE TECHNOLOGY LIMITED 8


Features:

Non corrosive stainless steel


design.

Leak proof long life up to 10 years.

Can be used multiple times till


the last drop, without losing its
effectiveness

Lock pin is intelligently designed,


where there is no chance of getting
jammed.

Non conductor up to 100kV power


supply. (Both AC and DC)

Discharge pipe is made from


SS304, ensures long operational
life.

The design is intelligently done to


provide a comfortable experience in
handling the extinguisher.
UL listed NASA 227 MAR model BIS listed NASA 200 MAR model
Uniform discharge pressure in
addition to unique dip tube design
ensures discharge of extinguishant
till the last drop(99+%),
maintaining the eficiency of the
extinguisher.

Unique discharge nozzle in


combination with discharge cap
and delector, helps to achieve
a homogenous mixture without
air pockets. Thus, increasing
the extinguishing capacity
instantaneously by getting a bigger
coverage area.

Cylinder Base Ring protects the


extinguisher from any impact due
to a fall.

UL approved label with excellent


UV protection, fastness and high
performance adhesion properties.
Also available in red color in capacities of 2kg, 4kg, 6kg respectively
Available in non-magnetic models,
compatible with medical diagnostic
equipments.

NASA FIRE TECHNOLOGY LIMITED 9


nasa semi-automatic accessories

We design with aesthetics in mind. Your extinguisher should not only be a


necessity, but also a welcome accessory to your home or workplace.

NASA FIRE TECHNOLOGY LIMITED 10


for private homes only

NASA FIRE TECHNOLOGY LIMITED 11


nasa automatic

NASA Clean Gas based automatic Fire Detecting and Extinguishing Units
are unique, hi-tech and intelligent devices meant to extinguish early stage
initial ires without taking anybodys consent. The uniqueness lies in its
independent working, without any external source of energy. It purely works
on Natures most reliable principle of gravity. No power source / batteries
required! Still 100% reliable. Over a period of 30 years of intensive research
and development efforts, the product design has been upgraded to perfection
by trying to eliminate every minuscule limitations and ensuring a smooth
TUV
reliable operation. These products come in various capacities ranging from SUD

0.35 kg (NASA 2T) to 11 kg (NASA 150T), depending on the volume of IS0 9001

application from 20 cubic feet to 670 cubic feet respectively.

unique valve design highly reliable temperature sensor UL approved pressure gauge specially
designed for NASA products

AUTOMATIC MODELS WITH UL LISTED NS_123 CLEAN GAS


Max. Coverage
Product Code Model Capacity (kg) Gross Weight (kg)
(cu ft)
NA_2T NASA 2T 0.35 1.00 20

NA_8T NASA 8T 0.75 1.75 45

NA_16T NASA 16T 1.00 2.30 60

NA_22T NASA 22T 1.80 3.10 110

NA_22TS NASA 22 SP 2.29 4.50 130

NA_42T NASA 42T 3.50 5.45 210

NA_100T NASA 100T 8.20 10.75 500

NA_150T NASA 150T 11.00 14.10 670

NASA FIRE TECHNOLOGY LIMITED 12


Features:

Non corrosive stainless steel


design.

Non conductor up to 100 kV power


supply. (Both AC and DC)

Ideal 24 hour protection for special


hazards where piped systems are
impractical.

Easy to install.

99+% of discharge providing


maximum extinguishant eficiency.

Valve automatic function is safe NASA 2T & NASA 8T with typical vertical model
in every manner, eliminating the vertical valve bodies installation inside electronic panel
chances of any valve component
falling during discharge.

Valve design ensures choke-free


nozzle operation.

Excellent solution for ire safety


and spot protection of critical
areas.

Depending on area of application NASA 16T with horizontal valve body NASA 42 T / NASA 100T / NASA 150T
and availability of space, NASA
automatic units are available in
horizontal and vertical models in
various capacities & temperature
ratings.

Suggested Applications:

Inside electric panels, server racks,


LPG cylinder chamber, car dickey
with CNG kit, enclosed solvent
drum storage warehouse, etc.

typical horizontal model installation inside server rack

NASA FIRE TECHNOLOGY LIMITED 13


nasa ire suppression system

Since many years, there is a practice of installing ire extinguishers outside


electric panels to safeguard against electric hazards. Now, when there is a
ire arising out of short circuit inside the panel, these extinguishers cease to
be of any effectiveness, since ire is inside and the extinguishant is sprayed
on the outer surface.

Considering the modern day infrastructure and industrial needs, there


are similar critical areas, which require 24 x 7 ire protection. NASA ire
TUV
suppression systems are specially customized and engineered clean agent SUD

based ire safety solutions to cater such requirements. These suppression IS0 9001

systems consist of advanced NASA leak proof valves, installed at a safe


place, along with preix pipes and unique discharge nozzles, going inside
the critical area, to suppress the ire. Property of NASA clean agent prevents
reignition, unless ventilated.

heavy duty weigh scale unique interlocking leakproof nozzle for manual discharge nozzle for automatic discharge
valve design

Applications: A range of Critical areas like data centres, server rooms, control rooms, electronics,
telecommunication rooms, LT/ HT electric panels, transformer areas, medical equipment, libraries and medical
record rooms, false ceilings, heat treatment furnaces (dip tanks), lammable liquid storage warehouses, Blow
room areas of textile industries, paint booths, paint mixing areas, coating operations, oil pumping stations, engine
compartments, engine and machinery spaces, CNC machines, conveyor ovens, commercial kitchens, exhaust
ducts etc., which require 24 x 7 ire protection.

NASA FIRE SUPPRESSION SYSTEM MODELS WITH UL LISTED NS_123 CLEAN GAS

Product Code Model Capacity Reach

NSS_250 TMH NASA 250 TMH 25 kg* 25 - 30 ft

NSS_500 TMH NASA 500 TMH 50 kg* 25 - 30 ft

* Total no. of cylinders and capacity of clean gas can be customized based on actual situation.

NASA FIRE TECHNOLOGY LIMITED 14


Features:

Based on survey of the area of


application, NASA engineers design
a customized ire suppression
system to it the customers safety
requirement

Provides extensive reach with the


designed piping network

Suitable for all A,B, C and


electrical ires

Non conductor up to 100 kV power


supply (Both AC and DC)

Interlocking Leak proof long life


valve design with 10 years gas
shelf life typical NASA ire suppression system

Available in both, self actuated


(thermal sensor based) as well
as manually actuated systems,
depending on the requirement

Uniform discharge pressure till


the last drop of extinguishent
(more than 98%), maintaining the
eficiency of the extinguisher

Unique discharge nozzle design,


gives excellent coverage area.

NASA NS_123 based Clean agent


leaves no residue with minimum
collateral damage and minimum
downtime. The area, simply needs
to be ventilated after application.

NASA suppression systems come


with a pressure gauge and a weigh
scale to monitor the constant
pressure and the amount of
extinguishent used.

NASA suppression system for typical electric panels,


with discharge nozzles going inside the panel

NASA FIRE TECHNOLOGY LIMITED 15


nasa mini ire tender

NASA Manual Movable ire extinguishing trolleys are mini ire tenders meant
to effectively extinguish early stage initial ire before it grows big. It has been
observed that Fire has a Tendency to Multiply 50 times in the irst 8 minutes.
And a Fire Tender would probably take on an average 20-45 minutes to reach
the site of ire. Just imagine the multiplication of ire in this period and the
kind of destruction that could have been averted by the mere presence of a
high performance NASA mini ire tender that could have done the job before
the ire multiplies. NASA mini ire tenders are equipped with interlocking
leak proof long life valve design, which ensures highly reliable operational TUV
SUD

performance. These trolleys come in various capacities ranging from 7.3 kg to IS0 9001

50 kg, depending on the area of application and the criticality of the material
handled.

unique interlocking valve design ensures minimum loss compact design for ease of storage

MANUAL MOVABLE MINI FIRE TENDER WITH UL LISTED NS_123 CLEAN GAS & PRESSURE GAUGE

Product Code Model Capacity (kg) Gross Weight (kg) Reach (ft)

NT_73 NASA 73 MMT 7.3 19.00 8-10

NT_100 NASA 100 MMT 10.0 22.00 8-10

NT_300 NASA 300 MMT 30.0 70.00 25-30

NT_500 NASA 500 MMT 50.0 90.00 35-40

NASA FIRE TECHNOLOGY LIMITED 16


Features:

Non corrosive stainless steel


design.

Interlocking leak proof long life


valve design.

To ensure minimum loss of


extinguishant during discharge,
additional working valve near the
nozzle is provided.

Can be used multiple times till the last


drop without losing its effectiveness.

Non-conductor up to 100 kV power


supply. (Both AC and DC)

99+% of discharge providing


maximum extinguishant eficiency.

Always ready at your doorsteps


to protect you and your premises
during ire emergency.

Excellent solution to control ires


from a range of 5 to 40 ft and for
ires in inaccessible areas like false
ceilings, warehouses, etc.

NASA FIRE TECHNOLOGY LIMITED 17


nasa mini ire tender

NASA FIRE TECHNOLOGY LIMITED 18


NASA MINI FIRE TENDER FIRE TENDER

Very small in size Very big in size

Anyone can operate Skills required to operate

Cost is less than 2 Lacs Cost may range in several Lacs

Zero response time Can be a very long response time

Minimum investment Large investment


Remaining material can be used again. No material loss Generally it adds futher loss of other material in the
because of Clean Gas based NASA design plant because of water used by Fire Brigade
Big Down Time to restore the activity and huge
No Down Time - no production loss
production loss
No residual effect. No cleaning is required Effort required to clean up because of residual effect

Low maintenance cost High maintenance costs

No recurring expenses Regular expenses


Always ready at your doorstep to protect you and your
May be unable to reach ire emergency in time
premises during ire emergency

NASA FIRE TECHNOLOGY LIMITED 19


nasa spill handling kit

Once upon a time, energy used to be generated by burning wood / coal.


There used to be sand buckets to extinguish these ires after the work was
done. Today, the world has moved on from wood / coal to kerosine followed
by gasoline and many other such fuels. But the practice of such old sand
buckets, which cease to be of any use in extinguishing these modern fuel
ires, is yet prevalent. They have not evolved.
NASA has developed some excellent lame retarding chemical granules,
which are free lowing and come with a 10 year lifetime. Packed in an TUV
SUD
excellent cassette design, it is very comfortable to handle these spill-kits in IS0 9001

contrast to the outdated conventional sand buckets.

outdated technology a hi-tech substitue a typical application

SPILL HANDLING KIT


Max. Area Coverage
Product Code Model Capacity (kg) Gross Weight (kg)
(sq ft)
NL_4 NASA LICI COVER 4.00 5.00 3 X 3

NASA FIRE TECHNOLOGY LIMITED 20


Features:

Unique Cassette design enables


very simple use, without any
pressure.

No maintenance required.

Excellent solution for managing


early stage small quantity solvent
spillage.

Easy to handle and carry to the


spot of application.

No detrimental effect to
environment or living beings.

Looks hi-tech.

Packing is not susceptible to


corrosive atmosphere.

Applications:

Petrol pumps, Reineries,


Laboratories, Oil burners, Pantry
/ kitchen area, Solvent tanks,
Railway engines, Hospitals,
Automobile workshops, etc.

NASA FIRE TECHNOLOGY LIMITED 21


nasa lame retardant chemical granules

Unattended cable trenches are one of the most critical hidden hazards
in modern day industries. Over a period of time, a signiicant amount of
garbage, water, oil etc gathers inside these trenches. Pests could be another
problem responsible for damaging some of these cables. Any ire arising
due to short circuit or fusing of such damaged cables will have the power
to spread across the entire cable trench enguling the entire industry into
lames and creating an inferno.
NASA lame retardant granules can be illed up in such cable trenches to
prevent any spread of ire across the trench. These granules are available in
different grades.

cable trench illed with nasa lame retardant chemical granules

NASA FIRE TECHNOLOGY LIMITED 22


Features:

Free lowing lame retardant


granules for ire safety of cable
trenches.

Eliminates cable damage by acting


as a barrier to rodents or pests.

No maintenance required.

No detrimental effect to
environment or living beings.

Very easy application right at the


time of laying down the cables. unattended cable trenches

Available in strong (5 year life)


and super strong (10 year life) in
different packing of 5 kg, 10 kg,
20 kg and 50kg.

Applications:

In all underground or on the ground


cable galleries in various industries
including reineries, ships, navy,
chemical industries, hospitals,
railways, etc.

electrical ire leading to inferno

cable trench illed with nasa lame


retardant chemical granules

NASA FIRE TECHNOLOGY LIMITED 23


nasa product gallery

typical NASA 2T installation inside typical NASA 8T installation inside typical NASA 16T installation inside
electrical panel electrical panel server rack

NASA 227 MAR installation at a steel NASA 42T installation on CNC machine NASA 42T installation on electrical panels
coating unit Note: Due to space constraint, the cylinder
stays outside the panel while the automatic
discharge nozzle goes inside the panel

NASA FIRE TECHNOLOGY LIMITED 24


NASA 100MMT for ire safety of an non magnetic NASA 227 MAR installed for typical NASA ire suppression system for ire
electrical research laboratory ire safety of MRI machine at a hospital safety of a color coating unit

typical NASA 227 MAR installation in a typical NASA ire suppression system for safety of electrical panels (in open condition)
hospital building

NASA FIRE TECHNOLOGY LIMITED 25


characteristics of extinguishing media used

UL approved NS_123 based NASA Liquid state when in pressurized


proprietary clean gas mixture used. condition.

Discharge as a liquid that rapidly Very effective invention to


evaporates in the atmosphere. extinguish ire and is a result of 30
years of usage experience.
Environmentally friendly and
has almost zero ozone depletion In contrast to conventional dry
potential. chemical agents which can be
corrosive, NS_123 leaves no
Colorless (like water) and has a residue after application causing
slightly ether like odor. little or no collateral damage on the
equipment in the vicinity of ire.
NS_123 is a safe, effective,
environmentally acceptable In terms of eficiency to extinguish
chemical blend based on the ire as well as its environmental
raw material HCFC-123. It was friendliness, NS_123 is a very well
originally introduced in the 90s balanced clean agent combination.
to replace severe ozone depleting
Halon 1211.

PHYSICAL PROPERTIES OF NS_123 (HCFC_123 BASED) EXTINGUISHING MEDIA

Chemical Formula C2HCI2F3 Vapour Pressure @ 25C 11.2 psig


Extinguishing Concentration:
Molecular Weight Approx. 150 g/mol 6 -7% by volume
N-Heptane Cup Burner
Acute Toxicity - Lowest
Boiling Point 25.5C @ 760 mm Hg 2%
Observed Adverse Effect Level
Acute Toxicity - No Observed
Liquid Density @ 25C 1460 kg/m3 1%
Adverse Effect Level

COMPARISON OF VARIOUS CLEAN GASES USED ACROSS THE WORLD


FM 200 / HFC 227ea/
Features NASA NS_123 FE36 / HFC 236fa Halon 1211 (Banned)
FE 227
Ozone Depletion
0.0098 0 0 7.1
Potential
Global Warming
77 3,220 9,810 1,890
Potential
Atmospheric Life Span 1.34 years 34.2 years 240 years 16 years

Reference: The case of new production of HCFC-123 beyond 2020 for use in production of Halotron I and in
other niche ire protection applications Prepared by: Hughes Associates, Inc. in July 1, 2009.

NASA FIRE TECHNOLOGY LIMITED 26


effectiveness comparison between NASA & CO2
volume enclosure 100 cu. feet

approximately approximately
7% concentration 38% concentration

nasa semi-automatic

nasa automatic

NASA FIRE TECHNOLOGY LIMITED 27


nasa semi-automatic technical details

MODEL: NASA 227 MAR MODEL: NASA 200 MAR


Item
PRODUCT CODE: NS_227 PRODUCT CODE: NS_200
UL Approved (Certiicate No: 20151217-
Certiication BIS Approved (CM/L - 7200017592)
EX15287)
Main container S.S. 304 Cylinder with 1.2 mm thickness S.S. 304 Cylinder with 1.2 mm thickness

Valve Body Pressure Die-Casted Stainless Steel 304 Pressure Die-Casted Stainless Steel 304
Discharge
Mechanism Leak Proof Auto Shut Off Mechanism Leak Proof Auto Shut Off Mechanism
UL listed NS_123 NASA Proprietary
Extinguishent HCFC 123 based Clean Agent
Clean Gas Mixture
Nozzle with
Conical Delector Multidirectional
Multidirectional

Discharge Cap S.S. 304 with black color powder coating S.S. 304 with black color powder coating
UL Approved Pressure Gauge compatible with UL Approved Pressure Gauge compatible with
Pressure Gauge
NASA NS_123 clean gas NASA NS_123 clean gas
Cylinder Pressure 100 psi 100 psi

Test Pressure 300 psi 300 psi

Range 2 - 3 meters 2 - 3 meters


Operating Temp
Range -40C to +49C -10C to +55C

Capacity 2.27 kg 2 kg

Rating 2B:C UL Rating 8B ISI Rating


UL Approved Clean Agent Detector/ as per BIS UL Approved Clean Agent Detector/ as per BIS
Tests
standards (calibrated to 18 grams / year) standards (calibrated to 18 grams / year)
Warranty 10 Years * 10 Years *

Discharge Time Minimum 16 Sec Minimum 16 Sec


Charge Retention:
End Discharge <1%
<1%

Shipping Weight 4.50 kg Max 4.50 kg Max


Empty Cylinder 2.0 kg Approx
2.1 kg Approx
Weight
Packing
56 x 33 x 19.5 56 x 33 x 19.5
Dimensions (cm)
* against manufacturing defects

NASA FIRE TECHNOLOGY LIMITED 28


MODEL: NASA 400 MAR MODEL: NASA 600 MAR
Item
PRODUCT CODE: NS_400 PRODUCT CODE: NS_600
Certiication As per BIS Speciications As per BIS Speciications

Main container S.S. 304 Cylinder with 1.2 mm thickness S.S. 304 Cylinder with 1.2 mm thickness

Valve Body Pressure Die-Casted Stainless Steel 304 Pressure Die-Casted Stainless Steel 304
Discharge
Mechanism Leak Proof Auto Shut Off Mechanism Leak Proof Auto Shut Off Mechanism

Extinguishent HCFC 123 based Clean Agent HCFC 123 based Clean Agent
Nozzle with
Conical Delector Multidirectional
Multidirectional

Discharge Cap S.S. 304 with black color powder coating S.S. 304 with black color powder coating
UL Approved Pressure Gauge compatible with UL Approved Pressure Gauge compatible with
Pressure Gauge
NASA NS_123 clean gas NASA NS_123 clean gas
Cylinder Pressure 125 psi 125 psi

Test Pressure 400 psi 400 psi

Range 3 - 4 meters 3 - 4 meters


Operating Temp
Range -10C to +55C -10C to +55C

Capacity 4 kg 6 kg

Rating 1A 13BC (ISI Rating) 2A 21BC (ISI Rating)


UL Approved Clean Agent Detector/ as per BIS UL Approved Clean Agent Detector/ as per BIS
Tests
standards (calibrated to 18 grams/year) standards (calibrated to 18 grams/year)
Warranty 10 Years * 10 Years *

Discharge Time Minimum 25 Sec Minimum 36 Sec


Charge Retention:
End Discharge <1%
<2%

Shipping Weight 7.50 kg max 10.00 kg max


Empty Cylinder 3.50 kg Approx
4.00 kg Approx
Weight
Packing
66 x 40 x 25 Approx 70 x 45 x 30 Approx
Dimensions (cm)
* against manufacturing defects

NASA FIRE TECHNOLOGY LIMITED 29


nasa automatic technical details

MODEL: NASA_2T MODEL: NASA_8T


Item
PRODUCT CODE: NA_2T PRODUCT CODE: NA_8T
Main container Stainless Steel - 304 Stainless Steel - 304
Valve Body
Pressure Die-Casted Stainless Steel - 304 Pressure Die-Casted Stainless Steel - 304
Assembly
UL Listed NS_123 NASA Proprietary Clean Gas UL Listed NS_123 NASA Proprietary Clean Gas
Extinguishent
Mixture Mixture
Nozzle with
Multi Directional Multi Directional
Conical Delector
UL listed NS_123 clean gas compatible UL UL listed NS_123 clean gas compatible UL
Pressure Gauge
approved pressure gauge approved pressure gauge
UL Approved Thermobulb Temp Range: UL Approved Thermobulb Temp Range:
Sensor
57 2C, 68 2C, 93 2C etc. 57 2C, 68 2C, 93 2C etc.
Installation
Aluminum Aluminum
Bracket
Capacity 0.35 kg 0.75 kg

Working Pressure 100 psi 100 psi

Test Pressure 300 psi 300 psi

Coverage 20 cubic feet 45 cubic feet

Max Height 4 feet 4 feet


Max Floor Area
16 square feet 16 square feet
Coverage
Charge Retention:
<1% <1%
End Discharge
Operating Source Temperature Temperature
Operating
Gravity Gravity
Mechanism
UL Approved Clean Gas Leak Detector UL Approved Clean Gas Leak Detector
Test
(calibrated to 18 grams/year) (calibrated to 18 grams/year)
Approx Shipping
1.0 kilogram 1.75 kilograms
Weight
Packing
26. 5 x 15.5 x 10.5 33 x 15.5 x 10.5
Dimensions (cm)

NASA FIRE TECHNOLOGY LIMITED 30


MODEL: NASA_16T MODEL: NASA_22T
Item
PRODUCT CODE: NA_16T PRODUCT CODE: NA_22T
Main container Stainless Steel - 304 Stainless Steel - 304
Valve Body
Pressure Die-Casted Stainless Steel - 304 Pressure Die-Casted Stainless Steel - 304
Assembly
UL Listed NS_123 NASA Proprietary Clean Gas UL Listed NS_123 NASA Proprietary Clean Gas
Extinguishent
Mixture Mixture
Nozzle with
Multi Directional Multi Directional
Conical Delector
UL listed NS_123 clean gas compatible UL UL listed NS_123 clean gas compatible UL
Pressure Gauge
approved pressure gauge approved pressure gauge
UL Approved Thermobulb Temp Range: UL Approved Thermobulb Temp Range:
Sensor
57 2C, 68 2C, 93 2C etc. 57 2C, 68 2C, 93 2C etc.
Installation
Aluminum Aluminum
Bracket
Capacity 1 kg 1.8 kg

Working Pressure 100 psi 100 psi

Test Pressure 300 psi 300 psi

Coverage 60 cubic feet 110 cubic feet

Max Height 5 feet 6 feet


Max Floor Area
25 square feet 36 square feet
Coverage
Charge Retention:
<1% <1%
End Discharge
Operating Source Temperature Temperature
Operating
Gravity Gravity
Mechanism
UL Approved Clean Gas Leak Detector UL Approved Clean Gas Leak Detector
Test
(calibrated to 18 grams/year) (calibrated to 18 grams/year)
Approx Shipping
2.3 kilograms 3.1 kilograms
Weight
Packing
40 x 19.5 x 12 21 x 21 x 25
Dimensions (cm)

NASA FIRE TECHNOLOGY LIMITED 31


nasa automatic technical details

MODEL: NASA_22TS MODEL: NASA_42T


Item
PRODUCT CODE: NA_22TS PRODUCT CODE: NA_42T
Main container Stainless Steel - 304 Stainless Steel - 304
Valve Body
Pressure Die-Casted Stainless Steel - 304 Pressure Die-Casted Stainless Steel - 304
Assembly
UL Listed NS_123 NASA Proprietary Clean Gas UL Listed NS_123 NASA Proprietary Clean Gas
Extinguishent
Mixture Mixture
Nozzle with
Multi Directional Multi Directional
Conical Delector
UL listed NS_123 clean gas compatible UL UL listed NS_123 clean gas compatible UL
Pressure Gauge
approved pressure gauge approved pressure gauge
UL Approved Thermobulb Temp Range: UL Approved Thermobulb Temp Range:
Sensor
57 2C , 68 2C, 93 2C etc. 57 2C , 68 2C, 93 2C etc.
Installation
Aluminum Aluminum
Bracket
Capacity 2.29kg 3.5 kg

Working Pressure 100 psi 100 psi

Test Pressure 300 psi 300 psi

Coverage 130 cubic feet 210 cubic feet

Max Height 7 feet 8 feet


Max Floor Area
49 square feet 64 square feet
Coverage
Charge Retention:
<1% <1%
End Discharge
Operating Source Temperature Temperature
Operating
Gravity Gravity
Mechanism
UL Approved Clean Gas Leak Detector UL Approved Clean Gas Leak Detector
Test
(calibrated to 18 grams/year) (calibrated to 18 grams/year)
Approx Shipping
4.5 kilograms 5.45 kilograms
Weight
Packing
56 x 33 x 19.5 21 x 21 x 25
Dimensions (cm)

NASA FIRE TECHNOLOGY LIMITED 32


MODEL: NASA_100T MODEL: NASA_150T
Item
PRODUCT CODE: NA_100T PRODUCT CODE: NA_150T
Main container Stainless Steel - 304 Stainless Steel - 304
Valve Body
Pressure Die-Casted Stainless Steel - 304 Pressure Die-Casted Stainless Steel - 304
Assembly
UL Listed NS_123 NASA Proprietary Clean Gas UL Listed NS_123 NASA Proprietary Clean Gas
Extinguishent
Mixture Mixture
Nozzle with
Multi Directional Multi Directional
Conical Delector
UL listed NS_123 clean gas compatible UL UL listed NS_123 clean gas compatible UL
Pressure Gauge
approved pressure gauge approved pressure gauge
UL Approved Thermobulb Temp Range: UL Approved Thermobulb Temp Range:
Sensor
57 2C , 68 2C, 93 2C etc. 57 2C , 68 2C, 93 2C etc.
Installation
Aluminum Aluminum
Bracket
Capacity 8.2 kg 11 kg

Working Pressure 100 psi 100 psi

Test Pressure 300 psi 300 psi

Coverage 500 cubic feet 670 cubic feet

Max Height 10 feet 12 feet


Max Floor Area
100 square feet 144 square feet
Coverage
Charge Retention:
<1% <1%
End Discharge
Operating Source Temperature Temperature
Operating
Gravity Gravity
Mechanism
UL Approved Clean Gas Leak Detector UL Approved Clean Gas Leak Detector
Test
(calibrated to 18 grams/year) (calibrated to 18 grams/year)
Approx Shipping
10.75 kilograms 14.1 kilograms
Weight
Packing
26 x 25 x 28.5 26 x 25 x 28.5
Dimensions (cm)

NASA FIRE TECHNOLOGY LIMITED 33


nasa mini ire tender technical details

MODEL: NASA 73 MMT MODEL: NASA 100 MMT


Item
PRODUCT CODE: NT_73 PRODUCT CODE: NT_100
Main Container Stainless Steel 304 Cylinder Stainless Steel 304 Cylinder
UL Approved Pressure Gauge compatible with UL Approved Pressure Gauge compatible with
Pressure Gauge
NASA NS_123 NASA NS_123
Master Valve
Stainless Steel 304 Cylinder Stainless Steel 304 Cylinder
Leak Proof
Flexible Tube Fibre Woven Hose of 3 meter Fibre Woven Hose of 3 meter
Spray Gun Nozzle
Stainless Steel 304 Stainless Steel 304
Valve
Spray Gun Stainless Steel 304 (1.2 meter) Stainless Steel 304 (1.2 meter)

Cylinder Pressure 125 psi 125 psi

Test Pressure 300 psi 300 psi

Capacity 7.3 kg 10 kg
UL listed NS_123 NASA Proprietary Clean UL listed NS_123 NASA Proprietary Clean
Extinguishent
Agent Gas Agent Gas
Time for
Approx 22 Seconds Approx 30 Seconds
Discharge
Discharge Rate Approx 330 grams / second Approx 330 grams / second
Standard Packing
Approx 19 kg Approx 22 kg
Weight
Safe Distance to
8 - 10 ft 8 -10 ft
Fight
Operating Temp
-40C to +55C -40C to +55C
Range
Charge Retention:
<1% <1%
End Discharge
Packing
30 x 30 x 120 30 x 30 x 120
Dimensions (cm)
Trolley Material
Stainless Steel 304 Stainless Steel 304
Construction
Trolley Castors Two (Stainless Steel 304) Two (Stainless Steel 304)

Trolley Wheels Two (Nylon) Two (UHMW)

NASA FIRE TECHNOLOGY LIMITED 34


MODEL: NASA 300_MMT MODEL: NASA 500_MMT
Item
PRODUCT CODE: NT_300 PRODUCT CODE: NT_500
Main Container Stainless Steel 304 Cylinder Stainless Steel 304 Cylinder
UL Approved Pressure Gauge compatible with UL Approved Pressure Gauge compatible with
Pressure Gauge
NASA NS_123 NASA NS_123
Master Valve
Stainless Steel 304 Cylinder Stainless Steel 304 Cylinder
Leak Proof
Flexible Tube Fibre Woven Hose of 1.5 meter Fibre Woven Hose of 3 meter
Spray Gun Nozzle
Stainless Steel 304 Stainless Steel 304
Valve
Spray Gun Stainless Steel 304 (0.5 meter) Stainless Steel 304 (1.2 meter)

Cylinder Pressure 125 psi 150 psi

Test Pressure 300 psi 400 psi

Capacity 30 kg 50 kg
UL listed NS_123 NASA Proprietary Clean UL listed NS_123 NASA Proprietary Clean
Extinguishent
Agent Gas Agent Gas
Time for
Approx 85 Seconds Approx 135 Seconds
Discharge
Discharge Rate Approx 350 grams / second Approx 375 grams / second
Standard Packing
Approx 70 kg Approx 90 kg
Weight
Safe Distance to
25 - 30 ft 35 - 40 ft
Fight
Operating Temp
-40C to +55C -40C to +55C
Range
Charge Retention:
<2%<2%
End Discharge
Packing
40.5 x 40.5 x 115 45 x 45 x 130
Dimensions (cm)
Trolley Material
Stainless Steel 304 Stainless Steel 304
Construction
Trolley Castors Four (Stainless Steel 304) (Stainless Steel 304)

Trolley Wheels Four (UHMW) (UHMW)

NASA FIRE TECHNOLOGY LIMITED 35


technical comparison

SUMMARY NASA SEMI AUTOMATIC VS CONVENTIONAL EXTINGUISHERS

Features NASA Water CO2 DCP Powder Mech Foam CO2


A, B, C & Electric BC/ ABC and
Effective on Class A Only B Only B&C
Fires Electric Fires
Pressurized By Argon Gas Cartridge Gas Cartridge Gas Cartridge CO2
Extinguishing UL Listed NS_123 Dry Chemical
Water AFFF CO2
Media Clean Gas Powder
Operating Semi Automatic /
Manual / Complex Manual / Complex Manual / Complex Manual / Complex
Mechanism Very Easy
Training Required None Skilled Operator Skilled Operator Skilled Operator Skilled Operator
Extinguishent
10 Years 1 Year 1 Year 1 Year 5 Years
Shelf Life
Clean Gas Mechanism Destroys Paper Destroys Possible
The Aftermath Heavy Cylinder
Safe for Machinery Documents Computers Electrocution
Multiple Usage Possible Not Possible Not Possible Not Possible Not Possible
10 Years Unless
Warranty 1 Year 1 Year 1 Year 1 Year
Seal is Broken

Detailed Comparison of NASA with CO2 Extinguisher:

Features NASA NS_123 Extinguisher CO2 Extinguisher


NS_123 gas comes out in liquid droplet form It is gas form, so gets mixed with air, hence the
Effectiveness
for long penetration and effective coverage. same is not very effective.
It requires only around 6-7% concentration to It requires approximately 38% - 40%
Application
control the ire. concentration to control the ire.
For effective usage it is to be used from very
Distance It can be used from a safe distance.
close distance of ire.
Weight Weighs around 4.5 kg Weighs around 18 kg
Multiple Time Maintains the pressure even after multiple Pressure drop on usage, so it is not possible to
Usage usage. use multiple times.
There is no formation of ice on discharge - the This generally results in ice formation on
Electrical Fire
operation is safe for electrical ire. discharge hence not safe on electric ires.
Cold Burn There are no chances of cold burn. There are chances of cold burn.
Static current
No possibility of static current generation. High possibility of static current generation.
generation
Design of the product makes it very easy to use Adequate training is required for operating it
Training
even for an untrained person. eficiently.
Maintenance and This does not require regular maintenance and This requires regular maintenance and
reilling periodical reilling. periodical reilling.
Entirely made of stainless steel (SS -304) so
Body Generally there is detrimental magnetic effect.
there is no detrimental magnetic effect.
All kind of ire It can be used for all three class of ire It cannot be used for all three class of ire

NASA FIRE TECHNOLOGY LIMITED 36


Detailed Comparison of NASA with AFFF (Aqueous Film Forming Foam) Extinguisher:

Features NASA NS_123 Extinguisher AFFF Extinguisher


Takes lesser time to cover the area under ire. Takes longer time to cover the area under ire.
Effectiveness

Effectiveness in
More effective. Generally takes more time - less effective.
oil / solvent ire
Effect on property /The Gas evaporates - has no residual effect.
It can spoil the property of material under ire.
material due to ire Preserves the property of material under ire.
Life of the No Protein based compound used, therefore Generally Protein based compound used,
product life of the product is longer. therefore life of the product is limited.
Subsequent Subsequent cleaning is not required hence no Subsequent cleaning is required, hence longer
Cleaning down time. downtimes and production losses.
Maintains the pressure even after using Pressure drop on usage, so it is not possible to
Multiple usage
multiple times. use multiple times.
Puncture and failure Internal liner is not required hence there is no Improper internal liner can lead to corrosion,
of extinguisher chance of puncture and failure of extinguisher puncture of liner and failure of extinguisher
Nonconductor to Nonconductor, tested up to 100 KV power Generally It is not good to use on live electrical
electrical ire supply on, can be used on live electrical ire. ire because of conductivity.
Design of the product makes it very easy to use Adequate training is required for operating it
Training
even for an untrained person. eficiently.
Use in extreme It can be used from -40 degree to +49 degree Generally, It is not eficient if used in negative
environment Celsius environment. temperature environment.
Maintenance and This does not require regular maintenance and This requires regular maintenance and
reilling periodical reilling. periodical reilling.

Detailed Comparison of NASA with DCP (Dry Chemical Powder) Extinguisher:

Features NASA NS_123 Extinguisher DCP Extinguisher


The Gas evaporates - has no residual effect.
Effect on property It can spoil the property of material under ire.
Preserves the property of material under ire.
Limited life as well as loses the eficiency over
Eficient life Stable for longer eficient life
a period of time.
Subsequent Subsequent cleaning is not required hence no Subsequent cleaning is required, hence a lot of
Cleaning down time. downtime and loss of productivity.
Maintains the pressure even after using Pressure drop on usage, so it is not possible to
Multiple usage
multiple times. use multiple times.
Puncture and failure Internal liner is not required hence there is no Improper internal liner can lead to corrosion,
of extinguisher chance of puncture and failure of extinguisher puncture of liner and failure of extinguisher
There is a visibility issue after discharge of
Visibility It is a clear gas therefore there is no visibility issue.
extinguisher.
Design of the product makes it very easy to use Adequate training is required for operating it
Training
even for an untrained person. eficiently.
Static current There is no possibility of static current There is a possibility of static current
generation generation. generation.
Maintenance and This does not require regular maintenance and This requires regular maintenance and
reilling periodical reilling. periodical reilling.
Made of stainless steel (SS -304) therefore Generally there is a detrimental magnetic
Body
there is no detrimental magnetic effect. effect.

NASA FIRE TECHNOLOGY LIMITED 37


select customer testimonials

The Proof is in the Pudding

NASA FIRE TECHNOLOGY LIMITED 38


NASA FIRE TECHNOLOGY LIMITED 39
select customer testimonials

NASA FIRE TECHNOLOGY LIMITED 40


NASA FIRE TECHNOLOGY LIMITED 41
frequently asked questions

Q. Are NASA stainless steel extinguishers completely non-corrosive?

A. Stainless Steel is LESS SUSCEPTIBLE to corrosion in most environments, and is far superior than mild steel
extinguishers. In extreme acidic environments, even Stainless Steel grades 304 and 316 have a tendency to corrode.
It is highly advised to safeguard your extinguishers in a safe enclosed cabinet to prevent damage from such extreme
environments.

Q. Is it possible to use NASA semi-automatic or mini ire tender multiple times? Does it leak out after single usage?

A. Unlike conventional extinguishers, the unique, advance and high-tech NASA leak proof valve design makes it
possible to use the NASA semi-automatic ire extinguisher or the NASA mini ire tender multiple times, till less than
1% charge retention. NASA products are good to use for a lifespan of 10 years without leakage.
For example, If you utilize a little quantity of the extinguishant today, and once the valve is totally closed, the
remaining extinguishant is still good to use till the remaining lifespan of 10 years without any signiicant pressure
drop or leakage.

Q. There are so many models in NASA automatic. How to make the right selection?

A. NASA automatic ire extinguisher comes in various capacities as shown in table on page no. 12. These different
capacities are recommended based on the volume of the critical chamber that needs to be protected. For example, if
we need to secure an LPG cylinder chamber, which is less than 20 cubic foot in volume, we can go with the smallest
model called NASA 2T. If we want to secure an electric panel with a volume of 35 cubic feet, we need to select the
higher model called NASA 8T. If we want to protect an enclosed solvent drum storage warehouse of 10ft x 6 ft x 10ft
(i.e. 600 cubic feet), we will prefer the highest capacity model called NASA 150T. We strongly recommend you to
consult NASA technical person to suggest the best suitable model for any given application.

Q. How do I make the right selection of suitable temperature rating sensor in NASA automatic for my application?

A. The idea behind selecting the right temperature rating sensor is to minimize the damage due to ire. For example,
server rack areas are maintained at 22-25C temperature. We would recommend a NASA automatic device with
temperature rating of 57C+/- 2C instead of 68C+/- 2C to minimize the damage. While for electric panels in
ambient temperature, we would not recommend a temperature rating of 57C+/- 2C. Instead we would go with 68
C+/- 2C or even higher, if required.

Q. Should we provide a total looding solution for ire safety of a server rack area?

A. While ire typically has a potential to initiate inside the server rack, we have observed a lot of industries providing
complete looding systems for the entire server room area. In following such a practice, a signiicant portion of the
server rack might get damaged by the time, ire is detected and extinguished. In contrast, NASA automatic devices
it right inside the server racks and immediately extinguish the ire that occurs inside the rack, thus preventing a
larger damage.

NASA FIRE TECHNOLOGY LIMITED 42


Q. When I used the extinguisher, I found that water is coming out.

A. No Sir, it is not water but it is the charged NASA NS_123 extinguishant, which looks like water. When you press
the valve lever slowly, it may so happen that little NASA Gas (NS_123) propels out in liquid droplet form and it
evaporates rapidly depending on the temperature conditions of the atmosphere without leaving any residue.

Q. Is NASA Clean Agent non-toxic?

A. NASA NS_123 clean agent is approved by Underwriters Laboratory, USA and NASA HCFC 123 based clean agent
is approved by BIS, India for ire extinguishing purposes. They are also approved under the US EPA under the SNAP
program as of October 21, 2014. NASA Clean Gas is one of the most balanced clean gases available, which can
extinguish a ire as well as have negligible effect on environment as compared to other clean gases. Ideally speaking,
the amount of carbon monoxide generated during ire is extremely detrimental to the environment, while a little
quantity of NASA clean gas used to extinguish the same would be completely harmless, non-toxic. (http://www.epa.
gov/ozone/snap)

Q. Is NASA Extinguishant compatible to the food or pharmaceutical industry?

A. NASA Clean gas may come out in liquid form, but it has a tendency to rapidly evaporate in gaseous phase.
In comparison to water or powder based extinguishers, it might cause negligible or no damage to the property of
substance on ire. Yet, it is dificult to validate its compatibility with each and every eatable item available on earth.

Q. How does the NASA Spill Handling Kit Licicover work? What is the application?

A. NASA Spill Handling Kit consists of free lowing coated granules, which have excellent absorbing as well as ire
extinguishing capacity. In contrast to the conventional outdated sand buckets, it is an excellent advanced technology,
which can be comfortably sprinkled on any oil/ solvent spillage, thereby absorbing it. In addition, when physically
sprinkled on a ire, the coating gets decomposed due to higher temperatures, thus creating a blanket to cover and
extinguish the ire.

Q. How do we use the NASA Flame Retardant Chemical Granules?

A. NASA Flame Retardant Chemical Granules are free lowing granules, which can be simply poured in the cable
trench, maintaining a minimum level of 5mm above the cables.

Q. How can I purchase a NASA product?

A. You can simply email us your requirement at sales@nasairetechnology.com

NASA FIRE TECHNOLOGY LIMITED 43


certiicates

CERTIFICATE CERTIFICATE
The Certification Body
The Certification Body
of TV SD South Asia Private Limited
of TV SD South Asia Private Limited
certifies that
certifies that

NASA FIRE TECHNOLOGY LIMITED NASA FIRE TECHNOLOGY LIMITED


24, Shreeji Industrial Estate, Behind Shanteshwar Mahadev,
C-2, Balaji Complex, Nehrupark, Vastrapur,
Behind BOC India Ltd., Soni- Ni- Chawl, NH No.8, Rakhial,
Ahmedabad - 380 015, Gujarat, INDIA
Ahmedabad - 380 023, Gujarat, INDIA

has implemented a Quality Management System


has implemented a Quality Management System
in accordance with ISO 9001:2008
in accordance with ISO 9001:2008
For Scope of
For Scope of

Design & Supply of Clean Agent Fire Extinguishers,


Manufacturing of Clean Agent Fire Extinguishers,
Fire Preventive Equipment & Systems.
Fire Preventive Equipment & Systems.

The certificate is valid in conjunction


The certificate is valid in conjunction
with the main-certificate From 2015-12-29 until 2016-08-29
Subject to successful completion of follow up audit before 2016-07-10 with the main-certificate From 2015-12-29 until 2016-08-29
The present status of this Certificate can be obtained on www.tuv-sud.in Subject to successful completion of follow up audit before 2016-07-10
Further clarifications regarding the scope of this certificate may be obtained by consulting the certification body The present status of this Certificate can be obtained on www.tuv-sud.in
Further clarifications regarding the scope of this certificate may be obtained by consulting the certification body
Certificate Registration No. 99 100 11957/01
Certificate Registration No. 99 100 11957/02
Date of Initial certification : 2013-08-30
Date of Initial certification : 2013-08-30

Certification Body Certification Body


of TV SD South Asia Private Limited, Mumbai of TV SD South Asia Private Limited, Mumbai
Member of TV SD Group Member of TV SD Group

TV SD South Asia Pvt. Ltd. TV SD House Saki Naka Andheri (East) Mumbai 400072 Maharashtra India TV SD South Asia Pvt. Ltd. TV SD House Saki Naka Andheri (East) Mumbai 400072 Maharashtra India

NASA FIRE TECHNOLOGY LIMITED 44


Proudly Made in India

Ahmedabad
C-2 Balaji Complex Nehru Park
Vastrapur Ahmedabad 380 015
+91.79.4002.8750
Mumbai
321 TV Industrial Estate SK Ahire Marg
Worli Mumbai 400 030
+91.22.2492.3197
New Delhi
A 183 Okhla Phase 1
New Delhi 110 020
+91.11.4140.6363
New York
61 Greenpoint Ave Suite 306
Brooklyn NY 11222
+1.212.473.9797

www.nasairetechnology.com
sales@nasairetechnology.com

Emergency Hotline 24/7


+91.93.7627.4021

Anda mungkin juga menyukai