Anda di halaman 1dari 3

www.sefindia.org :: View topic - Amplification of Accidental Torsional... https://www.sefindia.org/forum/viewtopic.php?

p=61784

www.sefindia.org
STRUCTURAL ENGINEERING FORUM OF INDIA [SEFI]

Search

Like 74k Share Follow @sefindia 4,041 followers

Subscriptions Digest Preferences FAQ Search Memberlist Usergroups Register Security Tips Donate
Profile Log in to check your private messages Log in to website Log in to forum
Warning: Make sure you scan the downloaded attachment with updated antivirus tools before opening them. They may contain viruses.
Use online scanners here and here to upload downloaded attachment to check for safety.

Amplification of Accidental Torsional moment as per ASCE7-05

www.sefindia.org Forum Index -> SEFI General Discussion

View previous topic :: View next topic

Author Message

gs70 Posted: Sat Nov 02, 2013 7:45 am Post subject: Amplification of Accidental Torsional moment as per
General Sponsor ASCE7-05

Dear Sefians

ASCE7-05 calls for Amplification of Accidental Torsional moment (cl.12.8.4.3). Can any one please
let me know how to apply this on ETABS model ? I attached the relevant codal provision herewith.

Joined: 19 Aug 2008 I am designing a Substation building in UAE and the Design approving authority asked for
Posts: 16 amplification of Accidental Torsional moment in ETABS or otherwise.

Thanks in anticipation.

Srinivas

Warning: Make sure you scan the downloaded attachment with updated antivirus tools before opening
them. They may contain viruses.
Use online scanners here and here to upload downloaded attachment to check for safety.

ASCE 7-05 Minimum Design Loads for buildings and other Struc 159.pdf
Description:
Filename: ASCE 7-05 Minimum Design Loads for buildings and other Struc 159.pdf
Filesize: 62.17 KB Download

Downloaded: 548 Time(s)

Back to top

btgprasad Posted: Wed Nov 06, 2013 9:31 am Post subject:


...
It may be possbile in ETABS if you define diaphram for each level.

run with 5% eccentricity (acc. torsion as in 12.8.4.2).check the deformed model for dispacements
delta max and delta ave for all levels as per 12.8.4.3.

calculate Ax for each level.


Joined: 05 Aug 2008
Posts: 117
calculate acc. eccentricity 5% of building width (0.05B) and multiply with Ax for each level.

Opt for overwrite eccentricities OPTION.enter absolute value for each level.

follow for same in other Y-direction.please let me know if it worked.

1 of 3 04/10/2017, 09:29
www.sefindia.org :: View topic - Amplification of Accidental Torsional... https://www.sefindia.org/forum/viewtopic.php?p=61784

Regards,
btg

untitled.jpeg.jpg
Description: i

Filesize: 72.47 KB
Viewed: 756 Time(s)

Back to top

gs70 Posted: Sat Nov 16, 2013 4:32 pm Post subject: Torsional amplification factor in ETABS
General Sponsor
Dear Mr Prasad

Thank you sir for the clear and detailed reply regarding my query.

It worked well.

Joined: 19 Aug 2008 Regards


Posts: 16
Srinivas

Back to top

Display posts from previous: All Posts Oldest First Go

All times are GMT


www.sefindia.org Forum Index -> SEFI General Discussion

Page 1 of 1

Jump to: SEFI General Discussion Go


Translate topic Go
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum

2003, 2008 SEFINDIA, Indian Domain Registration


Publishing or acceptance of an advertisement is neither a guarantee nor endorsement of the advertiser's product or service. advertisement policy

2 of 3 04/10/2017, 09:29
www.sefindia.org :: View topic - Amplification of Accidental Torsional... https://www.sefindia.org/forum/viewtopic.php?p=61784

Sign Up

3 of 3 04/10/2017, 09:29

Anda mungkin juga menyukai