KUAT TEKAN BETON


(ASTM C.39-95)
Contoh : Dikerjakan : Ir. A. Subagdja, MT.
Asal : Design Mixed K-225 Diperiksa :
Tanggal uji : Tanggal :

Dimensi sampel Berat Berat/ Beban P Kuat


Nomor p l t Sampel Volume Maksimum Tekan Ket.
Sampel
Cm Cm Cm Gram Gr/Cm3 KN Kgf/Cm2
1 2 3 4 5 6=5/(2x3x4) 7 8=7/(2x3) 9
1 15.00 15.00 15.00 8050.0 2.385 540 244.7
2 15.00 15.00 15.00 7950.0 2.356 465 210.7
3 15.00 15.00 15.00 8350.0 2.474 460 208.5
4 15.00 15.00 15.00 7970.0 2.361 405 183.5
5 15.00 15.00 15.00 8260.0 2.447 485 219.8
6 15.00 15.00 15.00 8300.0 2.459 565 256.1
7 15.00 15.00 15.00 8180.0 2.424 560 253.8
8 15.00 15.00 15.00 8225.0 2.437 935 423.7
9 15.00 15.00 15.00 8455.0 2.505 1075 487.2
10 15.00 15.00 15.00 8470.0 2.510 852 386.1
11 15.00 15.00 15.00 8550.0 2.533 695 315.0
12 15.00 15.00 15.00 8065.0 2.390 795 360.3
13 15.00 15.00 15.00 8031.0 2.380 920 417.0
14 15.00 15.00 15.00 8000.0 2.370 755 342.2
15 15.00 15.00 15.00 8400.0 2.489 780 353.5
16 15.00 15.00 15.00 8200.0 2.430 790 358.0
17 15.00 15.00 15.00 8060.0 2.388 620 281.0
18 15.00 15.00 15.00 8050.0 2.385 780 353.5
19 15.00 15.00 15.00 8100.0 2.400 850 385.2
20 15.00 15.00 15.00 8350.0 2.474 810 367.1
21 15.00 15.00 15.00 8000.0 2.370 825 373.9
Rata-rata 8191.2 2.427 712.5 322.9
Rata-Rata Kuat Tekan (sbm) Kgf/Cm 2
322.9
Standar Deviasi (Sd) Kgf/Cm2 82.53
Konstanta Statistik (k) 1.64
Kuat Tekan Karakteristik ((sbk) Kgf/Cm 2
188
Catatan:
1 KN = 101,9716 Kgf Kuat Tekan Beton ( b)= PA ( kgf/Cm )
2

Standar Deviasi ( Sd) =



n

1
n-1
( bm b)2 2
( kgf/Cm )
A

t
Kuat Tekan
Karakteristik ( bk )=
bm -k .. Sd ( kgf/Cm )
2

dimana:
P= Beban Tekan Maksimum ( kgf )
l p A= Luas Bidang Tekan ( Cm 2 ) = pxl
LABORATORIUM UJI BAHAN
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI BANDUNG
JL. GEGERKALONG HILIR DS. CIWARUGA KOTAK POS 6468 BDCD Tlp. (022) 2013789-2013898 Ext. 266 BANDUNG

KUAT TEKAN BETON


(ASTM C.39-95)
Contoh : Kubus Beton K-225 Dikerjakan : Ir. A. Subagdja, MT.
Asal : Design Mixed K-225 Diperiksa :
Tanggal uji : Tanggal :

Dimensi sampel Berat Berat/ Beban P Kuat


Nomor p l t Sampel Volume Maksimum Tekan Ket.
Sampel
Cm Cm Cm Gram Gr/Cm3 KN Kgf/Cm2
1 2 3 4 5 6=5/(2x3x4) 7 8=7/(2x3) 9
1 15.00 15.00 15.00 8050.0 2.385 540 244.7
2 15.00 15.00 15.00 7950.0 2.356 465 210.7
3 15.00 15.00 15.00 8350.0 2.474 460 208.5
4 15.00 15.00 15.00 7970.0 2.361 405 183.5
5 15.00 15.00 15.00 8260.0 2.447 485 219.8
6 15.00 15.00 15.00 8300.0 2.459 565 256.1
7 15.00 15.00 15.00 8180.0 2.424 560 253.8
8 15.00 15.00 15.00 8225.0 2.437 935 423.7
9 15.00 15.00 15.00 8455.0 2.505 1075 487.2
10 15.00 15.00 15.00 8470.0 2.510 852 386.1
11 15.00 15.00 15.00 8550.0 2.533 695 315.0
12 15.00 15.00 15.00 8065.0 2.390 795 360.3
13 15.00 15.00 15.00 8031.0 2.380 920 417.0
14 15.00 15.00 15.00 8000.0 2.370 755 342.2
15 15.00 15.00 15.00 8400.0 2.489 780 353.5
16 15.00 15.00 15.00 8200.0 2.430 790 358.0
17 15.00 15.00 15.00 8060.0 2.388 620 281.0
18 15.00 15.00 15.00 8050.0 2.385 780 353.5
19 15.00 15.00 15.00 8100.0 2.400 850 385.2
20 15.00 15.00 15.00 8350.0 2.474 810 367.1
21 15.00 15.00 15.00 8000.0 2.370 825 373.9
Rata-rata 8191.2 2.427 712.5 322.9
Rata-Rata Kuat Tekan (sbm) Kgf/Cm 2
322.9
Standar Deviasi (Sd) Kgf/Cm2 82.53
Konstanta Statistik (k) 1.64
Kuat Tekan Karakteristik ((sbk) Kgf/Cm 2
188
Catatan:
1 KN = 101,9716 Kgf Kuat Tekan Beton ( b)= PA ( kgf/Cm )
2

Standar Deviasi ( Sd) =



n

1
n-1
( bm b)2 2
( kgf/Cm )
A

t
Kuat Tekan
Karakteristik ( bk )=
bm -k .. Sd ( kgf/Cm )
2

dimana:
P= Beban Tekan Maksimum ( kgf )
l p A= Luas Bidang Tekan ( Cm 2 ) = pxl
LABORATORIUM UJI BAHAN
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI BANDUNG
JL. GEGERKALONG HILIR DS. CIWARUGA KOTAK POS 6468 BDCD Tlp. (022) 2013789-2013898 Ext. 266 BANDUNG

KUAT TEKAN BETON


(ASTM C.39-95)
Contoh : Kubus Beton K-225 Dikerjakan : Asep + Bejo
Asal : Ex. Lab. Diperiksa : 06.12.2005
Tanggal uji : Tanggal : 07.12.2005

Dimensi sampel Berat Berat/ Beban P Kuat


Nomor p l t Sampel Volume Maksimum Tekan Ket.
Sampel
Cm Cm Cm Gram Gr/Cm3 KN Kgf/Cm2
1 2 3 4 5 6=5/(2x3x4) 7 8=7/(2x3) 9
1 15.30 15.40 14.92 7591.3 2.159 159 68.8
2 15.20 15.20 15.20 7674.4 2.185 166 73.3
3 14.80 15.40 15.20 7351.9 2.122 148 66.2

Rata-rata 7539.2 2.156 157.7 69.4


Rata-Rata Kuat Tekan (sbm) Kgf/Cm 2
69.4
Standar Deviasi (Sd) Kgf/Cm2 3.57
Konstanta Statistik (k) 1.64
Kuat Tekan Karakteristik ((sbk) Kgf/Cm 2
64
Catatan:
1 KN = 101,9716 Kgf Kuat Tekan Beton ( b)= PA ( kgf/Cm )
2

Standar Deviasi ( Sd) =



n

1
n-1
( bm b)2
( kgf/Cm )
2

t
Kuat Tekan
Karakteristik ( bk )=
bm -k .. Sd ( kgf/Cm )
2

dimana:
P= Beban Tekan Maksimum ( kgf )
l p A= Luas Bidang Tekan ( Cm 2 ) = pxl
LABORATORIUM UJI BAHAN
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI BANDUNG
JL. GEGERKALONG HILIR DS. CIWARUGA KOTAK POS 6468 BDCD Tlp. (022) 2013789-2013898 Ext. 266 BANDUNG

KUAT TEKAN BETON (Compressive Strength of Cilindrical Specimens)


(ASTM C.39-96)
Mutu Beton (f'c): 25.0 MPa Jenis Sampel : Silinder Dia. 15 x 30 (Cm)
3625.9 Psi Dibuat tgl. : 02/12/2011
Diuji tgl. : 26/12/2011
Diperiksa : IR. A. SUBAGJA, MT.
Dimensi sampel Berat Beban Kuat Tekan beton (fc)
Nomor Berat/ Volume (f'cr-fc'i)
D T Sampel Maksimum 14 hari 28 hari
Sampel
mm mm Gram Gr/mm3 N Mpa MPa Mpa
1 2 3 4 5 6 7 8 9
1 150.60 301.90 12671.0 0.00236 525000 29.5 33.5 0.1
2 150.90 299.60 12634.0 0.00236 420000 23.5 26.7 42.0
3 150.90 300.20 12483.0 0.00232 520000 29.1 33.0 0.0
4 150.00 301.00 12550.0 0.00236 490000 27.7 31.5 2.8
5 150.40 304.30 12681.0 0.00234 495000 27.9 31.6 2.3
6 150.00 301.40 12560.0 0.00236 505000 28.6 32.5 0.5
7 152.00 303.30 12504.0 0.00227 570000 31.4 35.7 6.4
8 150.60 302.80 12517.0 0.00232 445000 25.0 28.4 22.8
9 151.00 300.90 12518.0 0.00232 425000 23.7 27.0 38.4
10 151.00 301.70 12576.0 0.00233 530000 29.6 33.6 0.2
11 150.80 301.20 12552.2 0.00233 610000 34.1 38.8 31.8
12 151.60 301.00 12609.2 0.00232 580000 32.1 36.5 11.2
13 151.30 299.70 12812.2 0.00238 560000 31.1 35.4 4.9
14 149.60 299.80 12436.1 0.00236 560000 31.8 36.2 9.2
15 150.40 299.60 12655.8 0.00238 560000 31.5 35.8 7.0
16 150.30 298.60 12539.8 0.00237 520000 29.3 33.3 0.0
17 150.40 301.00 12631.7 0.00236 535000 30.1 34.2 1.1
18 150.20 300.80 12599.1 0.00236 480000 27.1 30.8 5.7
19 150.80 301.90 12623.6 0.00234 560000 31.3 35.6 6.0
Rata-rata 0.00234 520526 29.2 33.2 = 192.5
Rata-Rata Kuat Tekan (f'cr) MPa 33.2
Standar Deviasi (SD) MPa 0.77
Faktor pengali 1.01
Konstanta Statistik (k) 1.66
Kuat Tekan Karakteristik (f'c) 28 hr MPa 31.9
f'c Rencana MPa 25.0

Catatan: :
Kuat Tekan Beton ( fc)=
P (MPa )
1 KN = 1000 N
A

( f'cr-fc)2
n

P
1
A Standar Deviasi ( Sd ) = ( MPa )
n-1
Kuat Tekan Karakteristik ( f'c)= f'cr-k. . Sd ( MPa )
dimana:
T P= Beban Tekan Maksimum ( kgf)
1
A= Luas Bidang Tekan ( Cm )
2
= D 2

4
D 1 MPa = 9,807966 kgf/Cm
2

219

C:\My Document/Bagdja/Format uji.doc


Compatibility Report for KUAT TEKAN REVISI.xls
Run on 07/01/2012 11:49

The following features in this workbook are not supported by earlier


versions of Excel. These features may be lost or degraded when opening
this workbook in an earlier version of Excel or if you save this workbook
in an earlier file format.

Minor loss of fidelity # of


occurrences

One or more objects in this workbook such as shapes, WordArt, or text 1


boxes may allow text to overflow the object boundaries. Earlier versions
of Excel do not recognize this option and will hide overflowing text.

Tekan Silinder'!A1:N52
Version

Excel 97-2003

Anda mungkin juga menyukai