Anda di halaman 1dari 10

Made Date Sheet

03-Nov-17 1
Check Date Rev.
04-Nov-17 0
PROJECT TITLE:RIYADH PAVILON
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (F1)
Geometrical Properties Material Properties
Depth of Soil overburden 2 m Weight of soil "soil" 18 kN/m3
Thickness of plain concrete 100 mm Weight of plain concrete "pc" 24 kN/m3
Thickness of Slab on garde 150 mm Weight of reinforced concrete "rc" 24 kN/m3
Depth of Column "D" 500 mm Safe bearing pressure "q" 100 kN/m2
Width of Column "B" 500 mm Eff. Net bearing pressure "qnet" 51.3 kN/m2
Required Area of footing 3 m2 Strength of concrete "fc" 30 N/mm2
Required Length of footing 1.79 m Strength of steel "fy" 420 N/mm2
Required Width of footing 1.78 m Clear cover to concrete 50 mm
Provided Length of footing "L" 1.8 m Dia of rebar 12 mm
Provided Width of footing "W" 1.8 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 3.24 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 350 mm s, constant depend on column location 40 Inetrior
Length of plain concrete 1.99 m Loading
Width of plain concrete 2.08 m Floor Finish on SOG 2 kN/m2
Live load on SOG 5 kN/m2
Reinforcement Service Dead Load "Pdl" 125 kN
Type of Reinforcement No. Area Service Live Load "Pll" 38 kN
Bottom Reinforcement Long dir. 11 1244.07 Live load reduction factor 1
Bottom Reinforcement Short dir. 11 1244.07 Total Serivce Load "Ptot" 163 kN
Total Ultimate Load "Pu,tot" 210.8 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 3.6 kN/m 2
REQUIRED DIMENSIONS 1.79 1.78 350
Soil overburden 36 kN/m2 PROVIDED DIMENSIONS 1.8 1.8 350
Adjust for Concrete 2.1 kN/m2
Total surcharge 48.7 kN/m2
Ult. press under RC base "pu" 66.1603164 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.699 N/mm2
Effective dept "d1" short dir 294.00 mm
Effective dept "d2" long dir 282.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 23.2223 kN/m
Shear stress short dir. 0.08 N/mm2 O.K < 0.699 N/mm2
Shear long dir /m 23.69 kN/m
Shear stress long dir. 0.08 N/mm2 O.K < 0.699 N/mm2
Made Date Sheet
0 03-Nov-17 2
Check Date Rev.
0 04-Nov-17 0
PROJECT TITLE:RIYADH PAVILON
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (F1)
````
Average effective depth "dav" 288.00 mm
Shear perimeter "bo" 3152.00 mm
Allowable shear stress is least of:
a) vc = *1+(2/c)f'c 2.10 N/mm2
6
b) vc = *0.083*(s*dav/bo + 2)f'c 1.93 N/mm2

c) vc = * 0.33*f'c 1.36 N/mm2

Therefore allowable shear stress vc = 1.36 N/mm2


Effective shear force at perimeter 169.718 kN
Actual shear stress 0.19 N/mm2 O.K < 1.36 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 25.1575 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85**f'c*L

Ast = 231.95 mm2


Ast,min = 0.0018*L*H 1134 mm2
Hence Provide Ast = 1134.00 mm2
Provide12mm dia 11 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2/(1+)
Therefore = L / W 1.00
Therefore revised reinforcement 11 No of bars dia 12 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 24.7719 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85**f'c*W

Ast = 228.38 mm2

Ast,min = 0.0018*W*H 1134 mm2


Hence Provide Ast = 1134.00 mm2

Provide12mm dia 11 No. of Bars


Made Date Sheet
03-Nov-17 1
Check Date Rev.
04-Nov-17 0
PROJECT TITLE: RIYADH PAVILON
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (F2)
Geometrical Properties Material Properties
Depth of Soil overburden 2 m Weight of soil "soil" 18 kN/m3
Thickness of plain concrete 100 mm Weight of plain concrete "pc" 24 kN/m3
Thickness of Slab on garde 150 mm Weight of reinforced concrete "rc" 24 kN/m3
Depth of Column "D" 300 mm Safe bearing pressure "q" 100 kN/m2
Width of Column "B" 300 mm Eff. Net bearing pressure "qnet" 51.3 kN/m2
Required Area of footing 1 m2 Strength of concrete "fc" 30 N/mm2
Required Length of footing 1.09 m Strength of steel "fy" 420 N/mm2
Required Width of footing 1.08 m Clear cover to concrete 50 mm
Provided Length of footing "L" 1.2 m Dia of rebar 12 mm
Provided Width of footing "W" 1.2 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 1.44 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 350 mm s, constant depend on column location 40 Inetrior
Length of plain concrete 1.29 m Loading
Width of plain concrete 1.38 m Floor Finish on SOG 2 kN/m2
Live load on SOG 5 kN/m2
Reinforcement Service Dead Load "Pdl" 50 kN
Type of Reinforcement No. Area Service Live Load "Pll" 10 kN
Bottom Reinforcement Long dir. 7 791.683 Live load reduction factor 1
Bottom Reinforcement Short dir. 7 791.683 Total Serivce Load "Ptot" 60 kN
Total Ultimate Load "Pu,tot" 76 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 3.6 kN/m 2
REQUIRED DIMENSIONS 1.09 1.08 350
Soil overburden 36 kN/m2 PROVIDED DIMENSIONS 1.2 1.2 350
Adjust for Concrete 2.1 kN/m2
Total surcharge 48.7 kN/m2
Ult. press under RC base "pu" 64.5599728 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.699 N/mm2
Effective dept "d1" short dir 294.00 mm
Effective dept "d2" long dir 282.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 6.52056 kN/m
Shear stress short dir. 0.02 N/mm2 O.K < 0.699 N/mm2
Shear long dir /m 6.97 kN/m
Shear stress long dir. 0.02 N/mm2 O.K < 0.699 N/mm2
Made Date Sheet
0 03-Nov-17 2
Check Date Rev.
0 04-Nov-17 0
PROJECT TITLE: RIYADH PAVILON
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (F2)
````
Average effective depth "dav" 288.00 mm
Shear perimeter "bo" 2352.00 mm
Allowable shear stress is least of:
a) vc = *1+(2/c)f'c 2.10 N/mm2
6
b) vc = *0.083*(s*dav/bo + 2)f'c 2.35 N/mm2

c) vc = * 0.33*f'c 1.36 N/mm2

Therefore allowable shear stress vc = 1.36 N/mm2


Effective shear force at perimeter 53.6788 kN
Actual shear stress 0.08 N/mm2 O.K < 1.36 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 7.84404 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85**f'c*L

Ast = 72.18 mm2


Ast,min = 0.0018*L*H 756 mm2
Hence Provide Ast = 756.00 mm2
Provide12mm dia 7 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2/(1+)
Therefore = L / W 1.00
Therefore revised reinforcement 7 No of bars dia 12 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 6.04378 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85**f'c*W

Ast = 55.59 mm2

Ast,min = 0.0018*W*H 756 mm2


Hence Provide Ast = 756.00 mm2

Provide12mm dia 7 No. of Bars


Made Date Sheet
03-Nov-17 1
Check Date Rev.
04-Nov-17 0
PROJECT TITLE: GRNADA CENTER 1942 DF
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (86)
Geometrical Properties Material Properties
Depth of Soil overburden 2.2 m Weight of soil "soil" 18 kN/m3
Thickness of plain concrete 100 mm Weight of plain concrete "pc" 24 kN/m3
Thickness of Slab on garde 250 mm Weight of reinforced concrete "rc" 24 kN/m3
Depth of Column "D" 500 mm Safe bearing pressure "q" 300 kN/m2
Width of Column "B" 500 mm Eff. Net bearing pressure "qnet" 244.4 kN/m2
Required Area of footing 7 m2 Strength of concrete "fc" 30 N/mm2
Required Length of footing 2.56 m Strength of steel "fy" 420 N/mm2
Required Width of footing 2.55 m Clear cover to concrete 50 mm
Provided Length of footing "L" 2.2 m Dia of rebar 16 mm
Provided Width of footing "W" 2.2 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 4.84 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 500 mm s, constant depend on column location 40 Inetrior
Length of plain concrete 2.76 m Loading
Width of plain concrete 3.05 m Floor Finish on SOG 2 kN/m2
Live load on SOG 5 kN/m2
Reinforcement Service Dead Load "Pdl" 1268 kN
Type of Reinforcement No. Area Service Live Load "Pll" 322 kN
Bottom Reinforcement Long dir. 12 2412.75 Live load reduction factor 1
Bottom Reinforcement Short dir. 10 2010.62 Total Serivce Load "Ptot" 1590 kN
Total Ultimate Load "Pu,tot" 2036.8 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 6 kN/m 2
REQUIRED DIMENSIONS 2.56 2.55 500
Soil overburden 39.6 kN/m2 PROVIDED DIMENSIONS 2.2 2.2 500
Adjust for Concrete 3 kN/m2
Total surcharge 55.6 kN/m2
Ult. press under RC base "pu" 312.009804 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.699 N/mm2
Effective dept "d1" short dir 442.00 mm
Effective dept "d2" long dir 426.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 183.462 kN/m
Shear stress short dir. 0.42 N/mm2 O.K < 0.699 N/mm2
Shear long dir /m 186.89 kN/m
Shear stress long dir. 0.44 N/mm2 O.K < 0.699 N/mm2
Made Date Sheet
0 03-Nov-17 2
Check Date Rev.
0 04-Nov-17 0
PROJECT TITLE: GRNADA CENTER 1942 DF
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (86)
````
Average effective depth "dav" 434.00 mm
Shear perimeter "bo" 3736.00 mm
Allowable shear stress is least of:
a) vc = *1+(2/c)f'c 2.10 N/mm2
6
b) vc = *0.083*(s*dav/bo + 2)f'c 2.27 N/mm2

c) vc = * 0.33*f'c 1.36 N/mm2

Therefore allowable shear stress vc = 1.36 N/mm2


Effective shear force at perimeter 1764.62 kN
Actual shear stress 1.09 N/mm2 O.K < 1.36 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 247.97 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85**f'c*L

Ast = 1531.77 mm2


Ast,min = 0.0018*L*H 1980 mm2
Hence Provide Ast = 1980.00 mm2
Provide16mm dia 10 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2/(1+)
Therefore = L / W 1.00
Therefore revised reinforcement 10 No of bars dia 16 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 364.112 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85**f'c*W

Ast = 2263.69 mm2

Ast,min = 0.0018*W*H 1980 mm2


Hence Provide Ast = 2263.69 mm2

Provide16mm dia 12 No. of Bars


Made Date Sheet
03-Nov-17 1
Check Date Rev.
04-Nov-17 0
PROJECT TITLE: GRNADA CENTER 1942 DF
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (86)
Geometrical Properties Material Properties
Depth of Soil overburden 2 m Weight of soil "soil" 18 kN/m3
Thickness of plain concrete 100 mm Weight of plain concrete "pc" 24 kN/m3
Thickness of Slab on garde 250 mm Weight of reinforced concrete "rc" 24 kN/m3
Depth of Column "D" 500 mm Safe bearing pressure "q" 300 kN/m2
Width of Column "B" 500 mm Eff. Net bearing pressure "qnet" 248 kN/m2
Required Area of footing 7 m2 Strength of concrete "fc" 30 N/mm2
Required Length of footing 2.57 m Strength of steel "fy" 420 N/mm2
Required Width of footing 2.56 m Clear cover to concrete 50 mm
Provided Length of footing "L" 2.2 m Dia of rebar 16 mm
Provided Width of footing "W" 2.2 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 4.84 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 500 mm s, constant depend on column location 40 Inetrior
Length of plain concrete 2.77 m Loading
Width of plain concrete 3.06 m Floor Finish on SOG 2 kN/m2
Live load on SOG 5 kN/m2
Reinforcement Service Dead Load "Pdl" 1292 kN
Type of Reinforcement No. Area Service Live Load "Pll" 336 kN
Bottom Reinforcement Long dir. 12 2412.75 Live load reduction factor 1
Bottom Reinforcement Short dir. 10 2010.62 Total Serivce Load "Ptot" 1628 kN
Total Ultimate Load "Pu,tot" 2088 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 6 kN/m 2
REQUIRED DIMENSIONS 2.57 2.56 500
Soil overburden 36 kN/m2 PROVIDED DIMENSIONS 2.2 2.2 500
Adjust for Concrete 3 kN/m2
Total surcharge 52 kN/m2
Ult. press under RC base "pu" 317.363813 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.699 N/mm2
Effective dept "d1" short dir 442.00 mm
Effective dept "d2" long dir 426.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 188.197 kN/m
Shear stress short dir. 0.43 N/mm2 O.K < 0.699 N/mm2
Shear long dir /m 191.69 kN/m
Shear stress long dir. 0.45 N/mm2 O.K < 0.699 N/mm2
Made Date Sheet
0 03-Nov-17 2
Check Date Rev.
0 04-Nov-17 0
PROJECT TITLE: GRNADA CENTER 1942 DF
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING (86)
````
Average effective depth "dav" 434.00 mm
Shear perimeter "bo" 3736.00 mm
Allowable shear stress is least of:
a) vc = *1+(2/c)f'c 2.10 N/mm2
6
b) vc = *0.083*(s*dav/bo + 2)f'c 2.27 N/mm2

c) vc = * 0.33*f'c 1.36 N/mm2

Therefore allowable shear stress vc = 1.36 N/mm2


Effective shear force at perimeter 1811.15 kN
Actual shear stress 1.12 N/mm2 O.K < 1.36 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 252.225 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85**f'c*L

Ast = 1558.42 mm2


Ast,min = 0.0018*L*H 1980 mm2
Hence Provide Ast = 1980.00 mm2
Provide16mm dia 10 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2/(1+)
Therefore = L / W 1.00
Therefore revised reinforcement 10 No of bars dia 16 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 373.965 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85**f'c*W

Ast = 2326.22 mm2

Ast,min = 0.0018*W*H 1980 mm2


Hence Provide Ast = 2326.22 mm2

Provide16mm dia 12 No. of Bars


Made Date Sheet
03-Nov-17 1
Check Date Rev.
04-Nov-17 0
PROJECT TITLE: GOSI RIMAL-SWITCH GEAR
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING 1
Geometrical Properties Material Properties
Depth of Soil overburden 1.5 m Weight of soil "soil" 18 kN/m3
Thickness of plain concrete 100 mm Weight of plain concrete "pc" 24 kN/m3
Thickness of Slab on garde 200 mm Weight of reinforced concrete "rc" 24 kN/m3
Depth of Column "D" 500 mm Safe bearing pressure "q" 150 kN/m2
Width of Column "B" 300 mm Eff. Net bearing pressure "qnet" 108.8 kN/m2
Required Area of footing 4 m2 Strength of concrete "fc" 35 N/mm2
Required Length of footing 2.16 m Strength of steel "fy" 420 N/mm2
Required Width of footing 1.95 m Clear cover to concrete 50 mm
Provided Length of footing "L" 1.7 m Dia of rebar 12 mm
Provided Width of footing "W" 1.7 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 2.89 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 400 mm s, constant depend on column location 40 Inetrior
Length of plain concrete 2.36 m Loading
Width of plain concrete 2.35 m Floor Finish on SOG 2 kN/m2
Live load on SOG 5 kN/m2
Reinforcement Service Dead Load "Pdl" 427 kN
Type of Reinforcement No. Area Service Live Load "Pll" 30 kN
Bottom Reinforcement Long dir. 11 1244.07 Live load reduction factor 1
Bottom Reinforcement Short dir. 11 1244.07 Total Serivce Load "Ptot" 457 kN
Total Ultimate Load "Pu,tot" 560.4 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 4.8 kN/m 2
REQUIRED DIMENSIONS 2.16 1.95 400
Soil overburden 27 kN/m2 PROVIDED DIMENSIONS 2.2 2 400
Adjust for Concrete 2.4 kN/m2
Total surcharge 41.2 kN/m2
Ult. press under RC base "pu" 133.048433 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.755 N/mm2
Effective dept "d1" short dir 344.00 mm
Effective dept "d2" long dir 332.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 64.6615 kN/m
Shear stress short dir. 0.19 N/mm2 O.K < 0.755 N/mm2
Shear long dir /m 65.59 kN/m
Shear stress long dir. 0.20 N/mm2 O.K < 0.755 N/mm2
Made Date Sheet
0 03-Nov-17 2
Check Date Rev.
0 04-Nov-17 0
PROJECT TITLE: GOSI RIMAL-SWITCH GEAR
LOCATION: RIYADH
DESIGN OF ISOLATED FOOTING 1
````
Average effective depth "dav" 338.00 mm
Shear perimeter "bo" 2952.00 mm
Allowable shear stress is least of:
a) vc = *1+(2/c)f'c 1.66 N/mm2
6
b) vc = *0.083*(s*dav/bo + 2)f'c 2.42 N/mm2

c) vc = * 0.33*f'c 1.46 N/mm2

Therefore allowable shear stress vc = 1.46 N/mm2


Effective shear force at perimeter 489.266 kN
Actual shear stress 0.49 N/mm2 O.K < 1.46 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 55.4147 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85**f'c*L

Ast = 436.06 mm2


Ast,min = 0.0018*L*H 1224 mm2
Hence Provide Ast = 1224.00 mm2
Provide12mm dia 11 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2/(1+)
Therefore = L / W 1.00
Therefore revised reinforcement 11 No of bars dia 12 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 77.9085 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85**f'c*W

Ast = 614.42 mm2

Ast,min = 0.0018*W*H 1224 mm2


Hence Provide Ast = 1224.00 mm2

Provide12mm dia 11 No. of Bars

Anda mungkin juga menyukai