Anda di halaman 1dari 4

JH Oilfield Equipment & Technologies, LLC MB2014-02

11433 Brittmoore Park Dr.,


Houston, TX 77041 Maintenance Bulletin
Tel: 281 6063230 Fax: 281 6063237

Top Drive

Weekly Maintenance

OPERATION ANDMaintenance
Weekly MAINTENANCE
Items PROCEDURE REV 2

1. Pin Roll of Lifting ring


Oil point
2 points on pin roll of bail
Lubricate method
Feed grease into the glib by grease gun.
Inspect Item
a Lubrication of bail pins.
b Baffle of bail pin and screw.

2. Guide beam and carriage.


Oil point
4 points on the bottom of tackle.
16 points on each side of tackle.

Lubricate method
Feed grease into the glib by grease gun, 2 washes
for each point.

Inspect Item
aInspect wheels working situation. No Blocks.
b. Check the wearing situation of the wheel,
replace it when necessary.
c. Inspect the fixed bolts on wheels
Page 1 of 4
JH Oilfield Equipment & Technologies, LLC MB2014-02
11433 Brittmoore Park Dr.,
Houston, TX 77041 Maintenance Bulletin
Tel: 281 6063230 Fax: 281 6063237

check whether the lock washer lock well.

3. Leaning Device

Inspect Item
a. Wearing situation on bolts of link
leaning hydraulic tank.
b. The position and clamps of lock
collar clamp on link.
c. The lubrication and lock of joint bearing.
Lubricate Point
Connecting pins of Joint bearings and rings.
Lubricate method
Lock collar
Feed grease into the glib by grease gun
clamp of link

4. Reactive torque inspection


Inspect Item
a. Inspect fixture of bolt.
b. Inspect the drift of reactive torque. It is
necessary to adjust the reactive torque if it
drifts away more than 3mm.

5. IBOP Maintenance
Oil Site
Remote control IBOP glib point 1, manual IBOP glib point 1.
Lubricating mode
Page 2 of 4
JH Oilfield Equipment & Technologies, LLC MB2014-02
11433 Brittmoore Park Dr.,
Houston, TX 77041 Maintenance Bulletin
Tel: 281 6063230 Fax: 281 6063237

Feed lubricating grease into glib by grease gun, twice for each points.

O
FF
O
FF

O
N
O
N

Remote IBOP
Manual IBOP

6. Loosen proof Device


Inspect Items
a Bolt fixture.
b Safety lock rope.
Installation of anti-loosing device
a. Cover molybdenum lubricating grease below bolt head on
the surface of locking bolt.
b. Make sure all the connecting joints are locked to the
required torque before installing the anti-loose device.
c. Clear the surface of IBOP, main shaft and protecting
connector. Ensure surfaces are bright and clean without any grease.
d. Put pairs of anti-loosing device on the joint.
e. Put the tong dies on the center of connection.
f. Fasten bolts by torque wrench, till the torque to 350 Nm.
g. Fix all bolts by steel wire.

Page 3 of 4
JH Oilfield Equipment & Technologies, LLC MB2014-02
11433 Brittmoore Park Dr.,
Houston, TX 77041 Maintenance Bulletin
Tel: 281 6063230 Fax: 281 6063237

7. Back-up Tong
Maintenance Item
a.Please disconnect the right side fixed pin only (initial
position of back-up tong, refers to the direction facing to
the top drive)
b.There is a grease fitting on the bottom of the pin of rig
ht side Grease 3-4 times for each fitting by grease gun

Fixed pin

Page 4 of 4