Block Diagram

Inlet % Flowrate Outlet % Flowrate


Components (kg/s) T120 Components (kg/s)
Water 66.4 0.1928 Water 66.40 0.1535
Filtate gas/liquid
Acetone 27.9 0.0810 Acetone 27.90 0.0644
separator
Monomer 5.70 0.0132
Monomer 5.70 0.01655
Total 100 0.2311
Total 100 0.29045

Components % Flowrate
to Ejector (kg/s)
Air 90 0.05341
Acetone 10 0.00593

Total 100 0.05934


Ejector

Item Number P121

Description Ejector

Number Off 1

Dimns. rate or capacity 2.20 m 3/s

Analysis of material handled Air 90%


Mass %
Acetone 10%

Material Mild steel

Working pressure 4 bar g

0.2 bar abs

Working temp. degrees C 140

Services LP steam

Remarks

Block Diagram
Dry air suction

Discharge to
Steam Jet Ejector
HP steam condensate
Calculation

1.0 Dry air suction

1.1 Determine the number of steam ejector stage

202.491

Source: Schutte&Koerting

Suction pressure given: 0.2 bar abs

: 202.491 mm Hg abs

: 5.90501 in Hg abs

From the graph given, the one stage of steam jet ejector has been chosen.
Suction temperature: ambient, 25o C

Air density at ambient temperature and 0.2 bar abs: 0.131 kg/m3

Air suction capacity: 213.628 kg/hr

From graph below:

5.90501

470.90 PPH

Source: Schutte&Koerting

470.90 PPH dry air = 213.628 kg/hr

1 lb/hr = 0.4535927 kg/hr


1.2 Determine the suction pipe diameter

Volumetric flow rate = 213.628 kg/hr 0.131 m3/kg

=1630.74 m3/hr

From the data Petronas Technical Standards PTS 31.38.01.11, November 2002

Preliminary piping size, velocities for air and other gases = 10 to 20 m/s

Piping size chosen:

Schedule 30
Nominal Pipe Size, mm 200
Inside diameter, mm 205.0
Inside area, cm2 330.2
Pipe suction diameter, in 8.0

Source: Schutte&Koerting
Source: Schutte&Koerting

Use reducer to reduce the 8 to 6 suction connection of steam jet ejector.

2.0 Discharge to condensate

2.1 Discharge rate given: 2.20 m3/s (7920 m3/hr)

Temperature: 25oc

Pressure: 1atm

Superheated steam velocity: 30 to 60 m/s (Source: Petronas Piping Guide)

From the data Petronas Technical Standards PTS 31.38.01.11, November 2002

Piping size chosen:

Schedule 30
Nominal Pipe Size, mm 300
Inside diameter, mm 307.1
Inside area, cm2 740.5
Pipe suction diameter, in 12.09

Use reducer to reduce the 12 to 6 discharge connection of steam jet ejector.


3.0 HP steam flow rate

3.1 Mass balance = 7920m3/hr 1630.74m3 /hr


= 6289.26 m3/hr

From the data Petronas Technical Standards PTS 31.38.01.11, November 2002

Superheated steam velocity: 30 to 60 m/s

Schedule 30
Nominal Pipe Size, mm 250
Inside diameter, mm 257.4
Inside area, cm2 520.5
Pipe suction diameter, in 10

Use reducer to reduce the 10 to 3 steam connection of steam jet ejector.

The size in inches chosen for the design is 6 based on the calculation.