EXPORT CONTROLLED Rolls-Royce
250-020 SERIES OPERATION AND MAINTENANCE
Table 9 (cont)
()Thislimitis applicable only during one-engine-inoperative (O.E |) operation of multi-engine aircraft
@ Thislimitis AA approvedtor continuous operation; butis authorized by the engine manufacturer only
during one-engine-inoperative (O.E |) operation of mutti-engine aircraft, andemergency engine op-
eration
® Refer to Special Inspections, Table 604, Engine-Inspection/Check, 72-00-09. Also, record
temperature and duration in the Engine Log Book (pink pages, Turbine Assembly, Part IV,
Inspection Record).
(Check Part V of the Engine Log for the part number of the Srd-stage turbine wheel. If the Srd-stage
Wheel is PIN689855 1, 6898567, 6899733, 6898743, 6898753 or 6898763, the following overtery
ature limits shall apply: 1) 810-927°C (1490—1700°F) for 10 seconds maximum or 2) 937°C (1700°F}
peak. Ifeither of these limits are exceeded, record the condition encountered in Part lof the Engine
Log, Return these Engine Log pages and the turbine to an Overhaul Agency for replacement of the
8rd-stage turbine wheel
NOTE: With the exception of the 810-899°C (1490-1650°F) temperature encountered for 6 to
Table 10
Output Shaft Torque Limits - 250-C20 Engine
Power
Torque Pressure at 100% No
tof (um) (KPa) hp kw) Time Limit
993 (633) 109 (782) 480) (336) 10 sec
967 (498) 101 (696) 420 (313) 30min
336 (456) 93 (641) 385 (287) Max Continuous*
302 (410) 83 (672) 346 (258) Continuous
NOTE: *This limit is FAA approved for continuous operation; but is authorized by the engine
manufacturer only during one-engine- inoperative (O.E.I.) operation of multi-engine aireratt,
and emergency engine operation.
72-00-00
Page 87
Jul 15/89
Rolls-Royce Proprietary Date = Uncontilled Printed CopyEXPORT CONTROLLED Rolls-Royce
250-C20 SERIES OPERATION AND MAINTENANCE
Table 9
Measured Gas Temperature Limits (TOT) ~ 250-C20B, ~C20F, ~C20J, -C208, ~C20W Engines:
‘Steady State
‘Temp Range Time Maintenance Action
810°C (1490: Takeoff (5 min) If steady state time or condition
10°C (1490°F) 30 minute power (1) limits are exceeded
810°C (1490°F) Max continuous (2) Inspect turbine (8)
Over 927°C (1700°F) Not Allowed Remove turbine for heavy rain-
tenance or overhaul (5),
-Duning Starting and Shutdown
‘Temp Range Ime Maintenance Action
Upto 810°C (1490°F) No limit None.
810-927°C (1490-1700°F) Over 10 seo (5) Inspect turbine (8) (4)
927-999°C (1700-1830°F) Not allowed (5) Inspect turbine (8) (4)
Over 999°C (1830°F) Not allowed Remove turbine for heavy
maintenance or overhaul
NOTE: Refer to Troubleshooting, 72-00-09, Table 101, item 9, when start temperature
consistently exceeds 860°C (1580°F).
During Power Transient
‘Tema Range Time ‘Maintenance Action
Upto 79°C (1484°F) No ltt (Transient only) None.
779-B10°C (1434-1480°F) Until stabilized (5 min max) None.
810-843°C (1490-1550°F) 0 to 6 sec (intentional use None.
of temperatures in excess
of 810°C (1490°F) is not
recommended)
B10-843°C (1490-1550°F) «Sto 12 seconds Max of 8 occurrences per life of
each turbine wheel (3) (4)
810-843°C (1490-1550°F) Over 12 seconds Inspect turbine (8) (4).
B43-927°C (1550-1700°F) Not allowed Inspect turbine (3) (4).
Over 927°C (1700°F) Not allowed Remove turbine for heavy
maintenance or overhaul
‘One Engine Inoperative andor Emergency
Multi-Engine Operation (250-C20B, ~C20F Engine!
Temp Range Time Maintenance Action
Up to 810°C (1490°F) No limit None,
810-843°G (1490-1550°F) to 6 seconds None,
843-899" (1550-1650°F) to 6 seconds Inspect turbine,
B10-888°C (1490-1850°F) 6 ta 12 seconds Max of 8 occurrences
per life of each
turbine wheel (8) (4).
B10 to 899°C (1490-1650°F) Over 12 seconds Remove turbine for
heavy maintenance
of overhaul
(Over 899°C (1650°F) Not allowed Remove turbine for
heavy maintenance
72-00-00
Page 56
dun 1/04,