Date 2014-04-30
HUAWEI TECHNOLOGIES CO., LTD.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 About This Document
1.1 Scope
1.2 Intended Audience
1.3 Change History
1.4 Differences Between Base Station Types
2 Overview of Handover
3 Intra-Frequency Handover
3.1 Overview
3.1.1 Intra-Frequency Soft Handover
3.1.2 Intra-Frequency Hard Handover
3.1.3 Inter RNC Handover
3.2 Intra-Frequency Handover Procedure
3.3 Intra-Frequency Handover Measurement
3.3.1 Intra-Frequency Handover Measurement Quantities
3.3.2 Intra-Frequency Handover Measurement Events
3.3.3 Triggering of Event 1A
3.3.4 Triggering of Event 1B
3.3.5 Triggering of Event 1C
3.3.6 Triggering of Event 1D
3.4 Intra-Frequency Handover Decision and Execution
3.5 Follow-up Procedures for Soft Handover Failures
3.5.1 Overview
3.5.2 Rate Reduction After an SHO Failure
3.5.3 D2F Transition After a Soft Handover Failure
3.5.4 E2D Reconfiguration After a Soft Handover Failure
3.6 Signaling Procedures for Intra-Frequency Handover
3.6.1 Intra-NodeB Intra-Frequency Soft Handover Signaling Procedure
3.6.2 Intra-RNC Inter-NodeB Intra-Frequency Soft Handover Signaling Procedure
3.6.3 Inter-RNC Intra-Frequency Soft Handover Signaling Procedure
3.6.4 Intra-RNC Inter-NodeB Intra-Frequency Hard Handover Signaling Procedure
3.6.5 Inter-RNC Intra-Frequency Hard Handover Signaling Procedure
3.7 Addition of Detected Set Cells to the Active Set
3.8 TTI Switch or E2D for BE Services Based on P-CPICH RSCP
3.9 Weak-Coverage-based or Low-Load-based SRB HS-DSCH to DCH
4 Inter-Frequency and Inter-RAT Handover
4.1 Overview
4.2 Inter-frequency and Inter-RAT Handover Switches
4.3 Signaling Procedures for Inter-Frequency Handover
4.3.1 Inter-Frequency Handover Within One RNC
4.3.2 Inter-Frequency Handover Between RNCs
4.4 Signaling Procedures for Inter-RAT Handover
4.4.1 3G-to-2G Handover in the CS Domain
4.4.2 3G-to-2G Handover in the PS Domain
4.4.3 3G-to-2G Handover in Both CS Domain and PS Domain
4.4.4 2G-to-3G Handover in the CS Domain
4.4.5 2G-to-3G Handover in the PS Domain
5 Coverage-based or QoS-based Handover
5.1 Coverage-based or QoS-based Handover Procedure
5.2 Coverage-based or QoS-based Handover Measurement
5.2.1 Overview
5.2.2 Coverage-based or QoS-based Handover Measurement Report Modes
5.2.3 Coverage-based or QoS-based Handover Measurement Quantity
5.2.4 Neighboring Cells to Be Measured
5.2.5 Coverage-based or QoS-based Handover Measurement Events
5.2.6 Penalty for Measurement Failures
5.2.7 BSIC Verification Requirements for 2G Cells
5.2.8 Inter-Frequency Measurements in Batches
5.3 Coverage-based or QoS-based Handover Decision and Execution
5.3.1 Inter-Frequency Coverage-based or QoS-based Handover Decision and Execution
5.3.2 3G-to-2G Coverage-based and QoS-based Handover Decision and Execution
5.4 Rules for 3G-to-2G Coverage-based or QoS-based Handover
5.5 3G-to-2G NACC
5.6 3G-to-2G PS Handover
5.7 2G-to-3G Handover
5.8 System Processing After a Handover Failure
5.8.1 Inter-Frequency Handover Failure
5.8.2 Inter-RAT Handover Failure
6 Non-Coverage-based Handover
6.1 Load-based Inter-Frequency Handover
6.1.1 Load-based Inter-Frequency Handover Procedure
6.1.2 Load-based Inter-Frequency Handover Measurement
6.1.3 Load-based Inter-Frequency Handover Decision and Execution
6.2 Load-based Inter-RAT Handover
6.2.1 Load-based Inter-RAT Handover Procedure
6.2.2 Load-based Inter-RAT Handover Measurement
6.2.3 Load-based Inter-RAT Handover Decision and Execution
6.3 Service-based Inter-RAT Handover
6.3.1 Switches for Service-based Inter-RAT Handover
6.3.2 Service-based Inter-RAT Handover Procedure
6.4 Rules for Enabling Load-based or Service-based Inter-RAT Handover
6.5 Interchanging Inter-RAT Load Information
7 HSPA Handover
7.1 HSDPA Handover
7.1.1 HSDPA Intra-Frequency Handover
7.1.2 HSDPA Inter-Frequency Handover
7.1.3 HSDPA Inter-RAT Handover
7.2 HSUPA Handover
7.2.1 HSUPA Intra-Frequency Handover
7.2.2 HSUPA Inter-Frequency Handover
7.2.3 HSUPA Inter-RAT Handover
7.3 HSPA+ Handover
7.3.1 Overview
7.3.2 Preselection Phase
7.3.3 Fallback Phase
7.3.4 Retry Phase
7.4 Anti-Frequent Serving Cell Change
7.5 HSPA Retry
8 HCS Handover
8.1 Overview
8.2 HCS Handover Procedure
8.3 UE Speed Estimation
8.4 HCS Handover Measurement
8.5 HCS Handover Execution
8.5.1 Inter-Layer Handover in Fast Movement
8.5.2 Inter-Layer Handover in Slow Movement
8.6 Signaling Procedure of HCS Handover
8.7 Interoperability Between HCS Handover and Other Handovers
8.7.1 Interoperability Between HCS Handover and Intra-Frequency Handover
8.7.2 Interoperability Between HCS Handover and Inter-Frequency Handover
8.7.3 Interoperability Between HCS Handover and Inter-RAT Handover
9 Blind Handover
9.1 Overview
9.2 Triggering of Event 1F
9.3 Blind Handover Based on Event 1F
10 Handover Protection
10.1 Anti-Ping-Pong
10.2 Handover Retry
10.2.1 Inter-Frequency Handover Retry
10.2.2 Inter-RAT (3G-to-2G) Handover Retry
10.3 Inter-RAT Multimedia Fallback
10.4 Transferring Event Report to Periodical Report
11 Neighboring Cell Combination
11.1 Overview
11.2 Neighboring Cell Combination Switches
11.3 Procedure of the Neighboring Cell Combination
12 Missing Neighboring Cell Detection
12.1 Overview
12.2 Missing Intra-Frequency Neighboring Cell Detection
12.3 Missing Inter-Frequency or Inter-RAT Neighboring Cell Detection
13 Compressed Mode
13.1 Overview
13.2 Compressed Mode Switches
13.3 Compression Methods
13.4 Compression Types
13.5 Measurement Timer Length
13.6 Check of Compressed Mode Parameter Settings During Inter-RNC Handover
13.7 Compatibility Switch for Dual-frequency Receiver
13.8 Compatibility Switches for HSPA
14 Related Features
14.1 WRFD-01061006 HSDPA Mobility Management
14.2 WRFD-01061204 HSUPA Mobility Management
14.3 WRFD-020304 Inter Frequency Hard Handover Based on DL QoS
14.4 WRFD-020309 Inter-RAT Handover Based on DL QoS
15 Network Impact
15.1 WRFD-020302 Inter Frequency Hard Handover Based on Coverage
15.1.1 System Capacity
15.1.2 Network Performance
15.2 WRFD-020304 Inter Frequency Hard Handover Based on DL QoS
15.2.1 System Capacity
15.2.2 Network Performance
15.3 Inter Frequency Hard Handover Based on UL QoS
15.3.1 System Capacity
15.3.2 Network Performance
15.4 WRFD-020309 Inter-RAT Handover Based on DL QoS
15.4.1 System Capacity
15.4.2 Network Performance
15.5 Inter-RAT Handover Based on UL QoS
15.5.1 System Capacity
15.5.2 Network Performance
15.6 WRFD-01061006 HSDPA Mobility Management
16 Engineering Guidelines
16.1 WRFD-020201 Intra Node B Softer Handover
16.1.1 Requirements
16.1.2 Activation
16.1.3 MML Command Examples
16.1.4 Activation Observation
16.1.5 Deactivation
16.1.6 MML Command Examples
16.2 WRFD-020202 Intra RNC Soft Handover
16.2.1 Requirements
16.2.2 Activation
16.2.3 MML Command Examples
16.2.4 Activation Observation
16.2.5 Deactivation
16.2.6 MML Command Examples
16.3 WRFD-020203 Inter RNC Soft Handover
16.3.1 Requirements
16.3.2 Activation
16.3.3 MML Command Examples
16.3.4 Activation Observation
16.3.5 Deactivation
16.3.6 MML Command Examples
16.4 WRFD-020301 Intra Frequency Hard Handover
16.4.1 Requirements
16.4.2 Activation
16.4.3 MML Command Examples
16.4.4 Activation Observation
16.4.5 Deactivation
16.4.6 MML Command Examples
16.5 WRFD-01061204 HSUPA Mobility Management
16.5.1 Requirements
16.5.2 Activation
16.5.3 Activation Observation
16.5.4 Deactivation
16.6 WRFD-01061404 HSUPA 2ms/10ms TTI Handover
16.6.1 Requirements
16.6.2 Activation
16.6.3 Activation Observation
16.6.4 Deactivation
16.7 WRFD-021200 HCS (Hierarchical Cell Structure)
16.7.1 Requirements
16.7.2 Activation
16.7.3 MML Command Examples
16.7.4 Activation Observation
16.7.5 Deactivation
16.7.6 MML Command Examples
16.8 WRFD-020302 Inter Frequency Hard Handover Based on Coverage
16.8.1 When to Use This Feature
16.8.2 Required Information
16.8.3 Requirements
16.8.4 Activation
16.8.5 MML Command Examples
16.8.6 Activation Observation
16.8.7 Deactivation
16.8.8 MML Command Examples
16.8.9 Performance Monitoring
16.9 WRFD-020304 Inter Frequency Hard Handover Based on DL QoS
16.9.1 When to Use This Feature
16.9.2 Required Information
16.9.3 Requirements
16.9.4 Activation
16.9.5 MML Command Examples
16.9.6 Activation Observation
16.9.7 Deactivation
16.9.8 MML Command Examples
16.10 Inter Frequency Hard Handover Based on UL QoS
16.10.1 When to Use This Feature
16.10.2 Required Information
16.10.3 Requirements
16.10.4 Activation
16.10.5 MML Command Examples
16.10.6 Activation Observation
16.10.7 Deactivation
16.10.8 MML Command Examples
16.11 WRFD-020303 Inter-RAT Handover Based on Coverage
16.11.1 Requirements
16.11.2 Activation
16.11.3 MML Command Examples
16.11.4 Activation Observation
16.11.5 Deactivation
16.11.6 MML Command Examples
16.12 WRFD-020309 Inter-RAT Handover Based on DL QoS
16.12.1 Requirements
16.12.2 Activation
16.12.3 MML Command Examples
16.12.4 Activation Observation
16.12.5 Deactivation
16.12.6 MML Command Examples
16.13 Inter-RAT Handover Based on UL QoS
16.13.1 Requirements
16.13.2 Activation
16.13.3 MML Command Examples
16.13.4 Activation Observation
16.13.5 Deactivation
16.13.6 MML Command Examples
16.14 WRFD-020308 Inter-RAT Handover Phase 2
16.14.1 Requirements
16.14.2 Deployment
16.15 WRFD-02030801 NACC(Network Assisted Cell Change)
16.15.1 Requirements
16.15.2 Activation
16.15.3 MML Command Examples
16.15.4 Activation Observation
16.15.5 Deactivation
16.15.6 MML Command Examples
16.16 WRFD-02030802 PS Handover Between UMTS and GPRS
16.16.1 Requirements
16.16.2 Activation
16.16.3 MML Command Examples
16.16.4 Activation Observation
16.16.5 Deactivation
16.16.6 MML Command Examples
16.17 WRFD-020305 Inter-RAT Handover Based on Service
16.17.1 Requirements
16.17.2 Activation
16.17.3 MML Command Examples
16.17.4 Activation Observation
16.17.5 Deactivation
16.17.6 MML Command Examples
16.18 WRFD-020306 Inter-RAT Handover Based on Load
16.18.1 Requirements
16.18.2 Activation
16.18.3 MML Command Examples
16.18.4 Activation Observation
16.18.5 Deactivation
16.18.6 MML Command Examples
16.19 WRFD-020310 3G/2G Common Load Management
16.19.1 Requirements
16.19.2 Activation
16.19.3 MML Command Examples
16.19.4 Activation Observation
16.19.5 Deactivation
16.19.6 MML Command Examples
16.20 WRFD-01061006 HSDPA Mobility Management
16.20.1 Requirements
16.20.2 Activation
16.20.3 Activation Observation
16.20.4 Deactivation
17 Parameters
18 Counters
19 Glossary
20 Reference Documents
1 About This Document
1.1 Scope
This document describes handover, including its technical principles, network impact, and engineering
guidelines. This document covers the following features:
WRFD-020201 Intra NodeB Softer Handover
Change Type
Feature change
Editorial change
RAN16.0 Draft A (2014-01-20)
Compared with Issue 05 (2013-12-30) of RAN15.0, Draft A (2014-01-20) of RAN16.0 includes the
following changes.
Base Station
Macro
Micro
LampSite
Feature Support by Macro, Micro, and LampSite Base Stations
Feature ID
WRFD-020201
Function Implementation in Macro, Micro, and LampSite Base Stations
NA
2 Overview of Handover
Handover is a basic function of the cellular mobile network. The purpose of handover is to ensure that a
UE in CELL_DCH state is served continuously when it moves.
Figure 2-1 shows the handovers supported by the Universal Mobile Telecommunications System (UMTS),
which include intra-frequency handover, inter-frequency handover, and inter-RAT handover.
Figure 2-1 Handovers supported by the UMTS
3 Intra-Frequency Handover
3.1 Overview
Intra-frequency handover is classified into:
Intra-frequency soft handover: Multiple radio links are connected to the UE at the same time
during handover.
Intra-frequency hard handover: Only one radio link is connected to the UE during handover.
Item
Scenario
Item
Uplink signal
Downlink signal
Resource use
Hysteresis value
1A
1B
1C
1D
NA is the number of cells not forbidden to affect the reporting range in the active set. The
parameter CellsForbidden1A(BSC6900,BSC6910) indicates whether adding the cell to the active
set affects the relative threshold of event 1A.
MBest is the measurement value of the best cell in the active set.
R1a is the reporting range or the relative threshold of soft handover. The threshold parameters of
the CS non-VP services, CS VP services, and PS services are as follows:
IntraRelThdFor1ACSNVP(BSC6900,BSC6910)
IntraRelThdFor1ACSVP(BSC6900,BSC6910)
IntraRelThdFor1APS(BSC6900,BSC6910)
NOTE:
For the PS and CS combined services, the thresholds for CS services are used.
For the single signaling connection of the UE, the thresholds for CS services are used.
C: curve of Th1A
NB is the number of cells not forbidden to affect the reporting range in the active set. The
parameter CellsForbidden1B(BSC6900,BSC6910) indicates whether adding the cell to the active
set affects the relative threshold of event 1B.
MBest is the measurement value of the best cell in the active set.
R1b is the reporting range or the relative threshold of soft handover. The threshold parameters of
the CS non-VP services, CS VP services, and PS services are as follows:
IntraRelThdFor1BCSNVP(BSC6900,BSC6910)
IntraRelThdFor1BCSVP(BSC6900,BSC6910)
IntraRelThdFor1BPS(BSC6900,BSC6910)
NOTE:
For the PS and CS combined services, the thresholds for CS services are used.
If the UE currently has only signaling connections, the thresholds for CS services are used.
C: curve of Th1B
CIONew is the cell individual offset value of the cell in the reporting range. It is equal to the sum
of CIO(BSC6900,BSC6910) and CIOOffset(BSC6900,BSC6910), which is the offset between the
cell in the reporting range and the best cell in the active set.
MInAS is the measurement value of the worst cell in the active set.
E: curve of Th1C
Th1C = (CPICH Ec/N0 of the worst cell in the active set) + (hysteresis/2)
where
Hysteresis is equal to the value of Hystfor1C(BSC6900,BSC6910).
If the signal quality of a cell not in the active set is higher than Th 1C for a period of time specified
by TrigTime1C(BSC6900,BSC6910) (Time to trigger in the figure), the UE reports event 1C, as shown in
the figure.
The UE reports event 1C for qualified cells after the number of cells in the active set reaches the
maximum value. The maximum number of cells in the active set can be set by
theMaxCellInActiveSet(BSC6900,BSC6910) parameter.
B: signal quality curve of a cell in the active set or the monitored set
C: curve of Th1D
NOTE:
To enable the UEs in the cells in the monitored set to report event 1D, you need to turn on the intra-
frequency hard handover switch, that is, select theHO_INTRA_FREQ_HARD_HO_SWITCH switch of
the HoSwitch(BSC6900,BSC6910) parameter in the SET UCORRMALGOSWITCH command.
Table 3-3 lists different types of intra-frequency handover decision and execution based on different
events.
Table 3-3 Intra-frequency handover decision and execution
1A
1B
1C
1D
When this switch is set to OFF, a serving cell change procedure is allowed.
NOTE:
The follow-up procedures for soft handover failures reduce the possibility of received total wideband
power (RTWP) or channel element (CE) congestion in a cell but increase the number of RB
reconfigurations and the call drop rate.
If the RNC receives a 1A, 1C, or 1D measurement report, the RNC tries to add the corresponding
cell to the active set. If the addition fails, the RNC performs the estimation procedure for rate
reduction.
Figure 3-6 Estimation procedure for rate reduction
1. The RNC evaluates whether the measurement quantity of the cell failing to be admitted meets the
condition of rate reduction.
If the condition is met, the RNC performs a rate reduction process for the access service
immediately, as described in the "Procedure of Rate Reduction Execution" section.
If the condition is not met, the RNC performs the next step (Step 2).
The condition of rate reduction is as follows: Mnew >
Mbest_cell - RelThdForDwnGrd(BSC6900,BSC6910)
Mnew is the CPICH Ec/N0 measurement value of the cell failing to be admitted.
Mbest_cell is the CPICH Ec/N0 measurement value of the best cell in the active set.
RelThdForDwnGrd(BSC6900,BSC6910) is a parameter.
2. The RNC evaluates whether the number of SHO failures in the cell exceeds
the ShoFailNumForDwnGrd(BSC6900,BSC6910).
If the number of SHO failures in the cell is smaller than
the ShoFailNumForDwnGrd(BSC6900,BSC6910):
If the timer has not been started, the RNC starts it.
If the timer has been started, the RNC increments the SHO failure counter by one.
The timer length is set through the parameter ShoFailPeriod(BSC6900,BSC6910).
The SHO failure counter of a cell is used to record the number of SHO failures in this cell. For
each UE, the RNC records the number of SHO failures in three cells at most. For SHO failures
in any other cells, the RNC does not record the number.
Before the SHO failure evaluation timer expires, no action is taken and the RNC waits for the
next measurement report period.
When the SHO failure evaluation timer expires, the RNC sets the SHO failure counter of the
corresponding cell to 0 and ends the evaluation.
If the number of SHO failures in the cell is larger than or equal to the
parameter ShoFailNumForDwnGrd(BSC6900,BSC6910), the RNC performs a rate reduction
process for the access service,
1. The RNC performs a rate reduction process for the access service.
To determine the access rate after the rate reduction, see the "Rate Negotiation at Admission
Control" section in Load Control Feature Parameter Description.
If the rate reduction fails, the RNC sets the SHO failure counter of the cell to 0 and ends the rate
reduction process.
2. If the rate reduction succeeds, the RNC makes an admission decision for the UE.
If admitting the UE to the cell succeeds, the RNC adds this cell to the active set without
measurement and adds the radio link for the UE.
If admitting the UE to the cell fails, the RNC starts the penalty timer
(DcccShoPenaltyTime(BSC6900,BSC6910)) to avoid a rate increase triggered by DCCC
within the period. When the penalty timer expires, the RNC sets the SHO failure counter of
the cell to 0 and ends the rate reduction process.
If the RNC fails to perform a soft handover again, it performs the estimation and execution
procedures, as previously described.
NOTE:
The RNC does not trigger E2D reconfiguration for the UE if the soft handover fails due to a downlink
admission failure. This is because the uplink resources of the target cell are not congested if only a
downlink admission failure occurs.
The connections involved in the intra-NodeB intra-frequency softer handover change are as follows:
Before the softer handover, only cell 1 is connected to the UE.
During the softer handover, both cell 1 and cell 2 are connected to the UE.
After the softer handover, only cell 2 is connected to the UE. Cell 1 is removed from the active
set.
Figure 3-9 Signaling procedure for intra-NodeB intra-frequency soft handover
After the soft handover, only NodeB 2 is connected to the UE. The active set of NodeB 1 is
removed.
Figure 3-11 Signaling procedure for intra-RNC inter-NodeB intra-frequency soft handover
After the SRNC makes a soft handover decision, it sets up a connection between NodeB 3 under
another RNC and the UE, and releases the connection between NodeB 1 and the UE.
Figure 3-13 Signaling procedure for inter-RNC intra-frequency soft handover
Figure 3-15 Signaling procedure for intra-RNC inter-NodeB intra-frequency hard handover
As shown in Figure 3-15, NodeB 1 is the source NodeB and NodeB 2 is the target NodeB.
As shown in Figure 3-17, NodeB 1 is the source NodeB and NodeB 2 is the target NodeB.
NOTE:
When the HO_INTRA_FREQ_DETSET_INTO_ACTSET_OPTSWH under the HoSwitch parameter is
turned on, the HO_INTRA_FREQ_DETSET_RPRT_SWITCH under theHOSWITCH parameter and
the HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH under the HOSWITCH parameter do not
need to be turned on, because the first switch incorporates the functions of the latter two switches.
Upon receiving an RRC CONNECTION SETUP COMPLETE message from a UE, the RNC
sends a measurement control message to the UE, instructing the UE to start a periodic P-CPICH
RSCP measurement task if the following conditions are both met:
Either DRA_BASE_COVER_BE_TTI_INIT_SEL_SWITCH in
the DraSwitch(BSC6900,BSC6910) parameter
or DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH in
theDraSwitch2(BSC6900,BSC6910) parameter is turned on. In
addition, BASE_RSCP_BE_TTI_E2D_INITSEL_EFFECT_SWITCH in
the RscpEffectAlgoSwitch parameter is turned on.
The value of the Establishment cause IE in the RRC CONNECTION REQUEST message is any
of the following: Originating Streaming Call, Originating Interactive Call, Originating Background
Call, Originating Subscribed traffic Call, Terminating Streaming Call, Terminating Interactive Call,
Terminating Background Call, Originating High Priority Signalling, Terminating High Priority
Signalling, Inter-RAT cell re-selection, and Inter-RAT cell change order.
If either of the preceding conditions is not met, the RNC does not send a measurement control
message to the UE.
The UE periodically reports measurement reports in unacknowledged mode (UM), thereby
preventing call drops caused by SRB-triggered RLC
reset.RrcRscpPeriodTimer(BSC6900,BSC6910) specifies the interval at which the UE
reports measurement reports. IntraFreqFilterCoef(BSC6900,BSC6910) specifies the
filtering coefficient.
Periodic P-CPICH RSCP Measurement for UEs with an RAB
After a UE has established a service or a reconfiguration procedure is complete, the RNC sends a
measurement control message to the UE, instructing the UE to start a periodic P-CPICH RSCP
measurement task or stop the current one and start a new task if the following conditions are both
met:
Either DRA_BASE_COVER_BE_TTI_RECFG_SWITCH in the DraSwitch parameter
or DRA_BASE_COVER_BE_E2D_SWITCH in the DraSwitch2 parameter is turned on. In
addition, BASE_RSCP_BE_TTI_E2D_RECFG_EFFECT_SWITCH in
the RscpEffectAlgoSwitch parameter is turned on.
The UE is in the CELL_DCH state and has established a PS BE service.
If either of the preceding conditions is not met, the RNC does not send a measurement control
message to the UE or sends a measurement control message to stop periodic P-CPICH RSCP
measurement.
The UE periodically reports measurement reports in UM, thereby preventing call drops caused
by SRB-triggered RLC reset. RabRscpPeriodTimer specifies the interval at which the UE
reports measurement reports. IntraFreqFilterCoef specifies the filtering coefficient.
The SRB of the UE is carried over HSDPA, and the UE is in the CELL_DCH state. For details
about SRB over HSDPA, see HSPA Evolution Feature Parameter Description.
If either of the preceding conditions is not met, the RNC does not send a measurement control message
to the UE or sends a measurement control message to stop periodic P-CPICH RSCP and Ec/N0
measurement.
The UE periodically reports measurement reports in UM, thereby preventing call drops caused by SRB-
triggered RLC reset. RsvU32Para8(BSC6900,BSC6910) specifies the interval at which the UE reports
measurement reports. IntraFreqFilterCoef(BSC6900,BSC6910) specifies the filtering coefficient.
NOTE:
Unless otherwise specified, inter-RAT handover refers to the handover performed between 3G and 2G
networks. For details about the handover between UMTS and LTE networks, seeInteroperability Between
UMTS and LTE Feature Parameter Description.
Type
Coverage-based handover
QoS-based handover
Type
Load-based handover
Service-based handover
HCS handover
Figure 4-2 Signaling procedure for inter-frequency handover between NodeBs within one RNC
As shown in Figure 4-2, NodeB 1 is the source NodeB, whereas NodeB 2 is the target NodeB. From step
1 through step 6, a new connection is set up. From step 7 through step 9, the original connection is
released.
NodeB 1 is the source NodeB, whereas NodeB 2 is the target NodeB. From step 1 through step 10, a
new connection is set up. From step 11 through step 13, the original connection is released.
For a UE in CELL_DCH state using both CS and PS domain services, the inter-RAT handover procedure
is based on the measurement reports from the UE but is initiated from the UTRAN.
The UE performs the inter-RAT handover from UTRA RRC connected mode to GSM connected mode
first. After the UE sends a HANDOVER COMPLETE message to the GSM/BSS, the UE initiates a
temporary block procedure towards the GPRS to suspend the GPRS services. After the CS domain
services are released on the GSM side, the inter-RAT handover in the PS domain is initiated and then
completed.
If the inter-RAT handover from UTRA RRC Connected Mode to GSM Connected Mode succeeds, the
handover is regarded as successful, no matter whether the UE initiates a temporary block procedure
towards the GPRS.
In case of inter-RAT handover failure, the UE may go back to the UTRA RRC Connected Mode and re-
establish the connection in the original state.
When the CS connection is terminated, the BSS may send a RESUME message to the SGSN. However,
resume is impossible since the radio access system has changed. Therefore, the SGSN acknowledges
the resume through a RESUME NACK message.
The UE sends a ROUTING AREA UPDATE REQUEST message to the SGSN to resume the GPRS
service. The update mode depends on the network operation mode in use.
Figure 4-7 Intra-SGSN service suspended and resumed
Figure 4-8 Inter-SGSN service suspended and resumed
5.2.1 Overview
If the UE can perform measurement only in compressed mode during the measurement phase, the RNC
needs to start the compressed mode before sending a measurement control message to the UE.
Otherwise, the RNC can directly send a measurement control message to the UE. Upon receipt of the
measurement control message, the UE performs inter-frequency or inter-RAT handover measurement.
For details about the compressed mode, see chapter 13 Compressed Mode.
Two RNC-level
timers, CsHoPrioMeasTimerLen(BSC6900,BSC6910) and PsHoPrioMeasTimerLen(BSC6900,BSC69
10), are available in the SET UHOCOMM command.
These timers specify the time interval from the time when an inter-frequency measurement control
message for CS or PS services is sent to the time when an inter-RAT measurement control message for
CS or PS services is sent. When a UE processing a CS or PS service is about to perform an inter-
frequency or inter-RAT handover, the RNC preferentially sends the UE an inter-frequency measurement
control message after compressed mode is started. If no inter-frequency neighboring cell meets the
required conditions or the inter-frequency handover fails, the RNC sends the UE an inter-RAT
measurement control message after the corresponding timer expires.
If CsHoPrioMeasTimerLen(BSC6900,BSC6910) or PsHoPrioMeasTimerLen(BSC6900,BSC69
10) is set to 0, the RNC sends the UE an inter-frequency measurement control message and an
inter-RAT measurement control message at the same time.
If CsHoPrioMeasTimerLen(BSC6900,BSC6910) or PsHoPrioMeasTimerLen(BSC6900,BSC69
10) is set to a non-zero value, the RNC preferentially sends the UE an inter-frequency measurement
control message. The RNC sends the UE an inter-RAT measurement control message only after the
corresponding timer expires.
The cell-level
timers CsHoPrioMeasTimerLen(BSC6900,BSC6910) and PsHoPrioMeasTimerLen(BSC6900,BSC691
0) are available in the ADD UCELLHOCOMM command. The meanings of the cell-level timers are the
same as those of the RNC-level timers. When both the cell- and RNC-level timers are set, the cell-level
timers prevail. During a handover, the timers in the best cell prevail.
During a coverage-based handover, if the CPICH signal quality of the current cell improves, the UE
reports event 2F. Then, the RNC stops the compressed mode and the coverage-based handover. For the
conditions for stopping a QoS-based handover for CS services, see the "Link Stability Control for AMR"
section in AMR Feature Parameter Description. For the conditions for stopping a QoS-based handover for
BE services, see the "Link Stability Control for BE" section in DCCC Feature Parameter Description.
The measurement control message contains the measurement report mode, measurement quantities,
neighboring cells to be measured, and parameters for measurement events.
When the measurement report conditions are met, the UE sends measurement reports to the RNC in
event-triggered report mode or periodical report mode. Based on the measurement reports received from
the UE, the RNC determines whether to perform a handover.
2D
2F
2B
3A
For details about event triggering conditions, see section 14.2.1 Inter-frequency reporting events and
14.3.1 Inter-RAT reporting event in 3GPP TS 25.331 V10.0.0.
Triggering of Event 2D
After the trigger conditions of event 2D are fulfilled and maintained until the value of the Event
2D Trigger Delay parameter is reached, the UE sends the event 2D measurement report
message.
Event 2D is triggered on the basis of the following formula:
QUsed TUsed2d - H2d/2
QUsed is the measured quality of the used frequency.
TUsed2d is the absolute quality threshold of the cell that uses the current frequency. It is specified by
the event 2D threshold. The event 2D threshold varies depending on the service type and
measurement quantity, as described in Table 5-2.
H2d is the event 2D hysteresis value. It is used to prevent ping-pong triggering of events 2D and
2F.
The principles for using event 2D-related parameters (event 2D trigger delay, hysteresis for event
2D, and threshold for triggering event 2D) in different scenarios are as follows:
When the neighboring cells are inter-frequency neighboring UMTS cells, event 2D-related
parameters configured for inter-frequency handover are used.
When the neighboring cells are neighboring GSM cells, event 2D-related parameters configured
for inter-RAT handover are used.
When the neighboring cells are neighboring LTE cells, event 2D-related parameters configured
for UMTS-to-LTE handover are used.
When the neighboring cells are neighboring LTE and GSM cells, event 2D-related parameters
configured for inter-RAT handover are used.
When the neighboring cells are neighboring LTE cells and inter-frequency neighboring UMTS
cells, event 2D-related parameters configured for inter-frequency handover are used.
When the neighboring cells are neighboring LTE cells, neighboring GSM cells, and inter-
frequency neighboring UMTS cells, or when the neighboring cells are neighboring GSM cells and
inter-frequency neighboring UMTS cells, the event 2D-related parameters to be used depend on the
setting of the CoexistMeasThdChoice(BSC6900,BSC6910)parameter.
If this parameter is set to COEXIST_MEAS_THD_CHOICE_INTERFREQ, event 2D-
related parameters configured for inter-frequency handover are used.
If this parameter is set to COEXIST_MEAS_THD_CHOICE_INTERRAT, event 2D-related
parameters configured for inter-RAT handover are used.
NOTE:
The CoexistMeasThdChoice(BSC6900,BSC6910) parameter is an RNC-level parameter and also a cell-
level parameter. The RNC-level CoexistMeasThdChoice(BSC6900,BSC6910)parameter can be set by
running the SET UHOCOMM command. The cell-
level CoexistMeasThdChoice(BSC6900,BSC6910) parameter can be set by running the ADD
UCELLHOCOMM command. If the cell-level CoexistMeasThdChoice(BSC6900,BSC6910) parameter
has been set, the setting of the RNC-levelCoexistMeasThdChoice(BSC6900,BSC6910) parameter does
not take effect.
Scenario Event
NOTE:
For the PS and CS combined services, when
the HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH switch under
the HoSwitch(BSC6900,BSC6910) parameter is set to ON, the threshold for triggering event 2D is
specified
by CSPSMRABThd2DEcN0(BSC6900,BSC6910) or CSPSMRABThd2DRSCP(BSC6900,BSC6910) for
inter-frequency or inter-RAT handover. Otherwise, the threshold is set to the higher of the CS or PS
services.
If the UE only has signaling connections, the threshold for triggering event 2D for CS services is used.
Triggering of Event 2F
After the trigger conditions of event 2F are fulfilled and maintained until the value of the Event
2F Trigger Delay parameter is reached, the UE sends the event 2F measurement report message.
Event 2F is triggered on the basis of the following formula:
QUsed TUsed2f + H2f/2
where
QUsed is the measured quality of the used frequency.
TUsed2f is the absolute quality threshold of the cell that uses the current frequency. It is specified by
the event 2F threshold. The event 2F threshold varies depending on the service type and
measurement quantity, as described in Table 5-3.
H2f is the event 2F hysteresis value. It is used to prevent ping-pong triggering of events 2D and
2F.
The principles for using event 2F-related parameters in different networking scenarios are the
same as those for using event 2D-related parameters. For details, see the "Triggering of Event
2D" section. Table 5-3 describes event 2F-related parameters.
Table 5-3 Event 2F-related parameters
Scenario Event
NOTE:
For the PS and CS combined services, when
the HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH switch under
the HoSwitch(BSC6900,BSC6910) parameter is set to ON, the threshold for triggering event 2F is
specified
by CSPSMRABThd2FEcN0(BSC6900,BSC6910) or CSPSMRABThd2FRSCP(BSC6900,BSC6910) for
inter-frequency or inter-RAT handover. Otherwise, the threshold is set to the higher of the CS or PS
services.
If the UE only has signaling connections, the threshold for triggering event 2F for CS services is used.
Triggering of Event 2B
After the trigger conditions of event 2B are fulfilled and maintained until the value of
the TimeToTrig2B(BSC6900,BSC6910) parameter is reached, the UE sends the event 2B
measurement report message.
Event 2B is triggered on the basis of the following formula:
QNoused TNoused2b + H2b/2
QUsed TUsed2b - H2b/2
where
QNoused is the measured quality of the cell that uses the other frequencies.
H2b is the event 2B hysteresis value set through the parameter HystFor2B(BSC6900,BSC6910).
TNoused2b is the quality threshold of the cells that use the target frequencies.
Based on the service type and measurement quantity, this threshold can be configured through
the following parameters:
TargetFreqCsThdEcN0(BSC6900,BSC6910)
TargetFreqCsThdRscp(BSC6900,BSC6910)
TargetFreqR99PsThdEcN0(BSC6900,BSC6910)
TargetFreqR99PsThdRscp(BSC6900,BSC6910)
TargetFreqHThdEcN0(BSC6900,BSC6910)
TargetFreqHThdRscp(BSC6900,BSC6910)
TUsed2b is the absolute quality threshold of the cell that uses the current frequency.
NOTE:
For the PS and CS combined services, when the
switch HoSwitch(BSC6900,BSC6910): HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH is set
to ON, TUsed2b is specified
by CSPSMRABThd2DEcN0(BSC6900,BSC6910) or CSPSMRABThd2DRSCP(BSC6900,BSC691
0), and TNoused2b is specified
byTargetFreqCSPSMRABThdEcNo(BSC6900,BSC6910) or TargetFreqCSPSMRABThdRscp(B
SC6900,BSC6910). Otherwise, the threshold is set to the higher of the CS or PS services.
If the UE only has signaling connections, the thresholds for CS services are used.
Triggering of Event 3A
After the trigger conditions of event 3A are fulfilled and maintained until the value of
the TrigTime3A(BSC6900,BSC6910) parameter is reached, the UE sends the measurement
report of event 3A.
Event 3A is triggered on the basis of the following formula:
QUsed TUsed - H3a/2 and MOtherRAT + CIOOtherRAT TOtherRAT + H3a/2
where
QUsed is the measurement value of the cell at the currently used frequency.
TUsed is the absolute quality threshold of the cell that uses the current frequency. Based on the
service type and measurement quantity in the coverage-based handover, TUsedcan be configured
through the following parameters:
UsedFreqCSThdEcN0(BSC6900,BSC6910)
UsedFreqCSThdRSCP(BSC6900,BSC6910)
UsedFreqHThdEcN0(BSC6900,BSC6910)
UsedFreqHThdRSCP(BSC6900,BSC6910)
UsedFreqR99PsThdEcN0(BSC6900,BSC6910)
UsedFreqR99PsThdRSCP(BSC6900,BSC6910)
In the coverage-based handover, based on the measurement quantity (CPICH Ec/N0 or
RSCP), TUsed is configured as follows:
If the measurement quantity is CPICH Ec/N0:
If event 2D is triggered by RSCP, TUsed is configured as the maximum value 0 dB.
If event 2D is triggered by Ec/N0, TUsed is configured as the Ec/N0 threshold specified by the
previous parameters.
If the measurement quantity is CPICH RSCP:
If event 2D is triggered by RSCP, TUsed is configured as the RSCP threshold specified by the
previous parameters.
If event 2D is triggered by Ec/N0, TUsed is configured as the maximum value -25 dBm.
In the uplink QoS-based handover, based on the measurement quantity (CPICH Ec/N0 or
RSCP), TUsed is configured as the maximum value according to section 10.37.39 Intra-
frequency measurement reporting criteria in 3GPP TS 25.331 V10.0.0, as described below:
If the measurement quantity is CPICH Ec/N0, TUsed is configured as the maximum value 0
dB.
If the measurement quantity is CPICH RSCP, TUsed is configured as the maximum value
-25 dBm.
In the downlink QoS-based handover:
If the measurement quantity is CPICH Ec/N0, TUsed is configured as the maximum value 0
dB.
If the measurement quantity is CPICH RSCP, based on the service type, TUsed can be
configured as one of the following sums:
UsedFreqCSThdRSCP(BSC6900,BSC6910)andDlRscpQosHyst(BSC6900,BSC6910)
UsedFreqR99PsThdRSCP(BSC6900,BSC6910)andDlRscpQosHyst(BSC6900,BSC69
10)
UsedFreqHThdRSCP(BSC6900,BSC6910)andDlRscpQosHyst(BSC6900,BSC6910)
MOtherRAT is the measurement value of the cell (in another RAT) in the reporting range.
CIOOtherRAT is the cell individual offset value of the cell (in another RAT) in the reporting range,
which is equal to the sum of CIO(BSC6900,BSC6910) andCIOOffset(BSC6900,BSC6910).
TOtherRAT is the absolute inter-RAT handover threshold. Based on different service types (CS
services, PS R99 services, or PS HSPA services), this threshold can be configured through the
following parameters:
TargetRatCsThd(BSC6900,BSC6910)
TargetRatR99PsThd(BSC6900,BSC6910)
TargetRatHThd(BSC6900,BSC6910)
For details, see Interoperability Between UMTS and LTE Feature Parameter Description.
5.2.6 Penalty for Measurement Failures
For coverage-based or QoS-based handovers, including inter-frequency handovers and 3G-to-2G
handovers, if the UE fails to send a useful measurement report (a measurement report is regarded as
useless if it does not contain any neighboring cells or does not meet the requirement) before the
measurement timer expires, a penalty is imposed on the UE as follows:
If an inter-frequency handover measurement in compressed mode was performed, this
measurement is stopped and the UE is prohibited from performing any inter-frequency handover
measurement in compressed mode triggered by any cause within the duration specified by the
penalty timer.
If a 3G-to-2G handover measurement in compressed mode was performed, this measurement is
stopped and the UE is prohibited from performing any 3G-to-2G handover measurement in
compressed mode triggered by any cause within the duration specified by the penalty timer.
The penalty timer is specified either by an RNC-level or cell-level
parameter PenaltyTimerForCMFailCov(BSC6900,BSC6910). The RNC-level parameter is set using
the SET UHOCOMM command and the cell-level parameter is set using the ADD
UCELLHOCOMM command.
When a UE keeps camping on a cell, it can only initiate one QoS-based inter-frequency or inter-RAT
handover in the cell. Therefore, if a UE fails to perform a QoS-based inter-frequency or inter-RAT
handover in a cell due to the compressed mode penalty, it can no longer initiate the same type of
handover as long as it keeps camping on the cell.
After receiving the periodical measurement report of the inter-frequency cell, the RNC starts the following
decision procedures:
1. Decides whether both the CPICH Ec/N0 value and CPICH RSCP value of the target cell pilot
signal meet the requirement of inter-frequency handover.
The evaluation formula is listed below:
Mother_Freq + CIOother_Freq Tother_Freq + H/2
where
Mother_Freq is the CPICH Ec/N0 or CPICH RSCP measurement value of the target cell
reported by the UE. Both of the two measurement values of the inter-frequency cell must
satisfy the formula.
CIOother_Freq is the cell individual offset value of the target cell. It is equal to the sum
of CIO(BSC6900,BSC6910) and CIOOffset(BSC6900,BSC6910).
Tother_Freq is the quality threshold of the cells that use the target frequencies during inter-
frequency handovers. For details, see the "Triggering of Event 2B" section.
H is the inter-frequency hard handover hysteresis value set through the
parameter HystForPrdInterFreq(BSC6900,BSC6910).
2. When InterFreqHOConsiderRTWPSw(BSC6900,BSC6910) is set to ON, the RNC checks
whether the RTWP and CPICH RSCP of a neighboring cell in the measurement report meet the
following formula: RTWP - CPICH RSCP < Target frequency uplink coverage limit threshold. If the
formula is met, the UE can perform a coverage-based inter-frequency hard handover to the
neighboring cell. When InterFreqHOConsiderRTWPSw(BSC6900,BSC6910) is set to OFF, the
RNC does not make the judgement.
The target frequency uplink coverage limit threshold is specified by bits 19 to 24 of
the RsvU32Para13 parameter in the SET UALGORSVPARA command.
The target frequency uplink coverage limit threshold is specified by
the TargetFreqUlCoverLimitThd parameter in the SET UCELLINTERFREQHOCOV command.
3. The RNC starts the hard handover time-to-trigger timer. The value of the hard handover time-to-
trigger timer is specified by theTimeToTrigForPrdInterFreq(BSC6900,BSC6910) parameter. The
RNC stops the timer when any of the following conditions is met:
Before the timer expires, if the RNC receives a measurement report from the UE and the
measurement report contains CPICH Ec/N0 and CPICH RSCP of a neighboring cell, the RNC
determines whether the following formula is met: Mother_Freq + CIOother_Freq < Tother_Freq - H/2. If the
formula is met, the RNC stops the timer and does not select the neighboring cell in the
measurement report as the target cell.
If the InterFreqHOConsiderRTWPSw(BSC6900,BSC6910) is set to ON, the RNC
checks whether the RTWP and CPICH RSCP of a neighboring cell meet the following
formula, RTWP-CPICH RSCP Target frequency uplink coverage limit threshold. If the
formula is met, the RNC stops the timer and does not select the neighboring cell in the
measurement report as the target cell. If
the InterFreqHOConsiderRTWPSw(BSC6900,BSC6910) is set to OFF, the RNC does not
make the judgement.
4. After the hard handover time-to-trigger timer expires, the RNC ranks the cells in the latest
measurement report in descending order by signal quality and selects the cell with the best signal
quality for inter-frequency handover. For example, the cell with the highest CPICH RSCP in the
latest measurement report is selected, as shown in Figure 5-2.
Figure 5-2 Selecting the cell with the highest CPICH RSCP
After receiving the event 2B measurement reports of CPICH RSCP and CPICH Ec/N0 for the inter-
frequency cell, the RNC starts the following procedure:
1. Adds all the pilot cells that trigger event 2B to a cell set and arranges the cells according to the
measurement quality of CPICH_Ec/N0 in descending order.
2. If the InterFreqHOConsiderRTWPSw(BSC6900,BSC6910) is set to ON, the RNC checks
whether the RTWP and CPICH RSCP of a neighboring cell in the measurement report meet the
following formula: RTWP - CPICH RSCP Target frequency uplink coverage limit threshold. If the
formula is met, the UE cannot perform a coverage-based inter-frequency hard handover to the
neighboring cell and the RNC deletes the neighboring cell from the cell set.
3. Selects a cell from the cell set in sequence and instructs the UE to perform a handover to the cell.
After receiving the periodical measurement report of GSM cells, the RNC performs the following decision
and execution procedure:
1. Decides whether the quality of 2G cells meets the conditions of inter-RAT handover.
The evaluation formula is listed below:
Mother_RAT + CIOother_RAT Tother_RAT + H/2
where
Mother_RAT is the measurement result of inter-RAT handover received by the RNC.
CIOother_RAT is the cell individual offset value of the target cell. It is equal to the sum
of CIO(BSC6900,BSC6910) and CIOOffset(BSC6900,BSC6910).
Tother_RAT is the quality threshold of the cells that use the target frequencies during inter-
RAT handovers. For details, see the "Triggering of Event 3A" section.
H is the inter-RAT handover hysteresis value set
through HystforInterRAT(BSC6900,BSC6910).
For the PS and CS combined services, the thresholds for CS services are used.
2. If the conditions described in 1 are met, the RNC starts the time-to-trigger timer.
The value of the time-to-trigger timer is specified by
the TimeToTrigForVerify(BSC6900,BSC6910) parameter (with BSIC acknowledged) or
theTimeToTrigForNonVerify(BSC6900,BSC6910) parameter (with BSIC unacknowledged). If the
RNC receives a measurement report from the UE before the timer expires and the signal quality of
a neighboring cell meets the following formula, the RNC stops the timer and does not select the
neighboring cell in the measurement report as the target cell:
Mother_RAT + CIOother_RAT < Tother_RAT - H/2
When the BSICVerify(BSC6900,BSC6910) parameter is set to REQUIRED, the BSIC
acknowledged mode is used. The BSICVerify(BSC6900,BSC6910) parameter is a cell-level
parameter and also a RNC-level parameter, which is set by running the ADD
UCELLINTERRATHOCOV and SET UINTERRATHOCOV commands, respectively.
3. After the time-to-trigger timer expires, the RNC ranks the cells in the latest measurement report in
descending order by signal quality and selects the cell with the best signal quality for inter-RAT
handover.
Before performing an inter-RAT handover, the RNC checks the signal quality of the best cell. If the
signal quality of the best cell is poor, the RNC does not trigger an inter-RAT handover. This
increases the inter-RAT handover success rate. The method of determining the signal quality of the
best cell is as follows:
The RNC checks whether the switches for reporting the signal quality of intra-frequency
neighboring cells in periodical inter-RAT measurement for a single CS service and a single PS
service, respectively, are turned on:
For a single CS service, the switch can be turned on by
selecting HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of
theHoSwitch1(BSC6900,BSC6910) parameter in the SET
UCORRMALGOSWITCH command.
For a single PS service, the switch can be turned on by
selecting HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of
theHoSwitch1(BSC6900,BSC6910) parameter in the SET
UCORRMALGOSWITCH command.
For CS and PS combined services, the switch is the same as that for a single CS service.
If at least one switch is turned on, the periodical inter-RAT measurement reports sent by the
UE to the RNC contain the signal quality information about the cells in the active set. The
RNC checks the signal quality of the best cell in the active set of the measurement report. If
an inter-RAT neighboring cell meets the conditions of inter-RAT handover, the RNC further
checks whether the Ec/N0 of the best cell in the active set meets the following formula:
Ec/N0 Lower Thd for Inter-RAT Intra-Frequency Handover
(UsedIRATHOLowerThdEcNo(BSC6900,BSC6910)) Ec/N0 of the best cell Ec/N0 Upper
Thd for Inter-RAT Intra-Frequency Handover
(UsedIRATHOUpperThdEcNo(BSC6900,BSC6910))
If the preceding formula is met, the RNC decides to perform an inter-RAT handover.
Otherwise, the RNC decides not to perform an inter-RAT handover. Note that the RNC needs
to send an intra-frequency neighboring cell measurement control message to the UE because
the RNC decides whether to perform an inter-RAT handover based on the signal quality of
intra-frequency neighboring cells. The size of the inter-RAT measurement report increases
when it contains the intra-frequency neighboring cell measurement result, increasing the call
drop rate.
If neither switch is turned on, the RNC selects a target cell and triggers a 3G-to-2G handover.
NOTE:
In an area where 2G and 3G networks are deployed, if the inter-RAT handover success rate is
lower than expected or if the customer is unsatisfied with the situation where the 3G network signal
quality is good enough for UEs to camp on but UEs are nevertheless handed over to the 2G
network, then:
Turn on the switch for a single CS service to increase the inter-RAT handover success
rate of CS services, that is, selectHO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of
the HoSwitch1(BSC6900,BSC6910) parameter.
Turn on the switch for a single PS service to increase the inter-RAT handover success
rate of PS services, that is, selectHO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of
the HoSwitch1(BSC6900,BSC6910) parameter.
Upon receipt of the first non-blank measurement report, the RNC selects a target cell according to the
policy described in Table 5-4.
Table 5-4 Target cell selection policy
Measurement Report on
After receiving the event 3A measurement report of 2G cells, the RNC performs the following decision
and execution procedure:
1. Puts all the 2G cells that trigger event 3A into a cell set and arranges the cells according to the
measurement quality in descending order.
2. Selects a cell from the cell set in sequence and instructs the UE to perform a handover to the cell.
Before deciding the 3G-to-2G handover, the RNC considers 2G cell capability, service capability, and UE
capability.
2G cell capability: 2G cell capability is configured through the
parameter RatCellType(BSC6900,BSC6910). This parameter indicates whether the cell supports
the GSM, GPRS, or EDGE.
Service required capability: The Required 2G Capability (Req2GCap(BSC6900,BSC6910))
specifies the capability of 2G cells required by inter-RAT handover. This indicates whether the
service is supported by the GSM, GPRS, or EDGE.
UE capability: Upon the reception of the UE capability information message, the RNC decides
whether to start the inter-RAT measurement. The information indicates whether the UE supports the
GSM, GPRS, or EDGE.
The following table describes the impacts of different types of capability on handover decision. If the
capability of all neighboring 2G cells does not meet the requirement, the inter-RAT measurement will not
be triggered.
Table 5-5 Impacts of different types of capability on handover decision
The RNC initiates the coverage-based or QoS-based UMTS-to-GSM handover only when Service
Handover Indicator is as follows:
HO_TO_GSM_SHOULD_BE_PERFORM
HO_TO_GSM_SHOULD_NOT_BE_PERFORM
The RNC triggers a service-based or load-based 3G-to-2G handover only when the Service Handover
Indicator is set to HO_TO_GSM_SHOULD_BE_PERFORM.
The IE Service Handover Indicator indicates the CN policy for the service handover to the 2G network.
This IE is indicated in the Radio Access Bearer (RAB) assignment signaling assigned by the CN, or
provided by the RNC side.
The algorithm
switch HoSwitch(BSC6900,BSC6910): HO_INTER_RAT_RNC_SERVICE_HO_SWITCH decides
whether the service attribute of inter-RAT handover is based on the RNC or the CN.
If the switch is set to ON, the service attribute of inter-RAT handover is based on the parameter
configured on the RNC side.
If the switch is set to OFF, the service attribute of inter-RAT handover is first based on the CN
when the indicator is contained in the RAB assignment signaling assigned by the CN. If the CN does
not allocate a service indicator, the service attribute of inter-RAT handover is based on the RNC
side.
Through the SHIND(BSC6900,BSC6910) parameter, the service handover indicators are set as follows:
HO_TO_GSM_SHOULD_BE_PERFORM: means that the handover to the 2G network is
performed when 2G signals are available.
HO_TO_GSM_SHOULD_NOT_BE_PERFORM: means that the handover to the 2G network is
performed when 3G signals are weak but 2G signals are strong.
HO_TO_GSM_SHALL_NOT_BE_PERFORM: means that the handover to the 2G network is not
performed even when 3G signals are weak but 2G signals are strong.
By default, the RNC does as follows:
For a UE with a single signaling RAB, the RNC supports the handover to the GSM, which is not
recommended.
For the UE accessing combined services (with CS services), the RNC sets the service handover
indicator of the UE to that of CS services, because CS services have the highest QoS priority.
For the UE accessing combined services (with only PS services), the RNC sets the service
handover indicator of the UE to that of PS services with the highest QoS priority
If the service handover indicators are not configured by the CN, each indicator can be set to the service
parameter index of a service on the RNC. Each service parameter index is the index of one typical
service RAB, which involves a set of service type, source description, CN domain ID, and maximum rate
(bit/s).
NOTE:
RIM messages can be exchanged between the UTRAN and GERAN through the eCoordinator when the
following conditions are met:
Huawei devices used in the UTRAN and GERAN are connected to the same eCoordinator.
The CN to which the UTRAN and GERAN connect does not support the RIM procedure or the
RIM procedure is not enabled for the UTRAN and GERAN.
When the RIM procedure is performed through the eCoordinator, the switches for the RIM procedure
must be set to on for NEs involved in the procedure, such as BSC, eCoordinator, and RNC. Otherwise,
the RIM procedure cannot be performed through the eCoordinator and these NEs cannot send RIM
messages to or respond to RIM messages from the CN.
With NACC, the RNC sends a cell change order carrying the SI/PSI of the GERAN to the UE when a
UMTS-to-GSM handover is triggered. To enable the NACC function, do as follows:
Run the SET UCORRMALGOSWITCH command to
set HoSwitch(BSC6900,BSC6910): HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH to
ON.
Run the ADD UEXT2GCELL or MOD UEXT2GCELL command to
set SuppRIMFlag(BSC6900,BSC6910) to TRUE.
(Optional) Select the RIM_ON_ECO_SWITCH check box under
the PROCESSSWITCH5(BSC6900,BSC6910) parameter in the SET URRCTRLSWITCH command
when the RIM procedure is performed through the eCoordinator.
6 Non-Coverage-based Handover
Non-coverage-based handover consists of load-based handover and service-based handover:
Load-based handover can be further classified into two types:
Load-based inter-frequency handover. For details, see section 6.1 Load-based Inter-
Frequency Handover.
Load-based inter-RAT handover. For details, see section 6.2 Load-based Inter-RAT
Handover.
Service-based handover can be further classified into two types:
Service-based inter-frequency handover. For details, see the "Inter-Frequency DRD for
Service Steering" section in Directed Retry Decision Feature Parameter Description.
Service-based inter-RAT handover. For details, see section 6.3 Service-based Inter-RAT
Handover.
The inter-frequency cells with the same coverage area have the same CPICH RSCP values. By
measuring the CPICH RSCP of the serving cell, the RNC obtains quality of the cells with the same
coverage area and determines whether to allow a blind handover, which increases the probability of
successful blind handover.
1. The RNC initializes the timer of intra-frequency measurement for blind handover. The timer is
specified by internal algorithm and does not need to be configured.
2. The RNC initiates a periodical intra-frequency measurement.
The measurement report mode is set to periodical report.
The reporting period is BlindHOIntrafreqMRInterval(BSC6900,BSC6910).
The list of measured cells contains only the cells that trigger LDR.
3. After receiving from the UE the intra-frequency measurement reports for conditional blind
handover, the RNC checks whether the following condition is met:
CPICH RSCP of the cell in the measurement report
BlindHOQualityCondition(BSC6900,BSC6910)
If the condition is met, the RNC increments the counter of the number of intra-frequency
measurement reports for blind handover by 1.
If the condition is not met, the RNC does not perform a blind handover to the cell that
triggers LDR and stops intra-frequency measurement for blind handover.
4. When the counter reaches the value of BlindHOIntrafreqMRAmount(BSC6900,BSC6910), the
RNC initiates a blind handover to the target cell.
If the counter does not reach this value, the RNC waits for the next intra-frequency measurement
report from the UE.
5. If the timer of intra-frequency measurement for blind handover expires, the RNC does not perform
a blind handover to the target cell and stops intra-frequency handover measurement for blind
handover.
If the inter-frequency handover based on coverage or QoS is triggered, the RNC stops the intra-frequency
measurement for conditional blind handover.
1. The LDR algorithm learns that a cell is in basic congestion and provides target cells and the UE
with low priority for handover.
2. The RNC selects the target cell based on the measurement results. The report period is specified
by the parameter PrdReportInterval(BSC6900,BSC6910).
The target cell must meet the following conditions:
The CPICH RSCP value of the target cell is larger
than TargetFreqThdRscp(BSC6900,BSC6910).
The CPICH Ec/N0 value of the target cell is larger
than TargetFreqThdEcN0(BSC6900,BSC6910)
The target cell is not in the basic congestion state.
The RNC performs an inter-frequency hard handover to the target cell directly.
CIOOtherRAT is the cell individual offset value of the cell (in another RAT) in the reporting range,
which is equal to the sum of CIO(BSC6900,BSC6910) andCIOOffset(BSC6900,BSC6910).
TOtherRAT is the absolute inter-RAT handover threshold. Based on different service types (CS, PS
domain R99 services, or PS domain HSPA services), this threshold can be configured through the
following parameters:
InterRATNCovHOCSThd(BSC6900,BSC6910)
InterRATNCovHOPSThd(BSC6900,BSC6910)
For the PS and CS combined services, the thresholds for CS services are used.
Except for the triggering phase, the procedure of service-based inter-RAT handover is the same as that of
the Load-based inter-RAT handover. For details, see section 6.2.3 Load-based Inter-RAT Handover
Decision and Execution.
When a service is established, the RNC requests the handover to the GSM based on the service type and
service handover indicator assigned by the CN.
Figure 6-3 shows an example of rules for the indicator of the 3G-to-2G handover based on load and
service.
Figure 6-3 Example of rules for indicator of 3G-to-2G handover based on load and service
HO_TO_GSM_SHOULD_NOT_BE_PERFORM
The RNC initiates the service-based 3G-to-2G handover only when the Service Handover Indicator is
HO_TO_GSM_SHOULD_BE_PERFORM.
Before deciding the 3G-to-2G handover, the RNC considers 2G cell capability
(RatCellType(BSC6900,BSC6910)), service required capability (Req2GCap(BSC6900,BSC6910)) and
UE capability.
The following table describes the impacts of different types of capability on handover decision.
Table 6-1 Impacts of different types of capability on handover decision
If the capability of all neighboring 2G cells does not meet the requirement, the inter-RAT measurement
will not be triggered.
The procedure for load information interchanging between the source 3G cell and target 2G cell
is described as follows:
1. When the RNC sends a RELOCATION REQUIRED message to the 3G CN,
If the switch SndLdInfo2GsmInd(BSC6900,BSC6910) is set to ON, the RELOCATION
REQUIRED message includes the Old BSS To New BSS Information IE that includes the load
information of the 3G source cell.
If the switch SndLdInfo2GsmInd(BSC6900,BSC6910) is set to OFF, then the RELOCATION
REQUIRED message does not include the Old BSS To New BSS Information IE.
2. When the RNC receives the RELOCATION COMMAND message from the 2G CN,
If the switch NcovHoOn2GldInd(BSC6900,BSC6910) is set to ON, the RNC obtains the load
information of the 2G target cell by reading the Inter-System Information Transparent Container IE,
which is included in the RELOCATION COMMAND message.
If the 2G load is lower than CSHOOut2GloadThd(BSC6900,BSC6910) (for CS service),
or if the 2G load is lower than PSHOOut2GloadThd(BSC6900,BSC6910)(for PS service), the
RNC continues the inter-RAT handover procedure; otherwise, the RNC returns the Relocation
Cancel message to the CN to cancel this inter-RAT handover and makes another handover
attempt to the next candidate cell generated in the cell list based on inter-RAT measurement.
If the Inter-System Information Transparent Container IE, is not included in the
RELOCATION COMMAND message, the load information of the 2G target cell is not
considered and this inter-RAT handover is continued.
If the switch NcovHoOn2GldInd(BSC6900,BSC6910) is set to OFF, the RNC continues the
inter-RAT handover procedure without considering the thresholds.
In 2G-to-3G handover based on load or service, the RNC can make an admission decision
considering the load information of the 3G target cell. This can avoid the worsening of the 3G
system performance caused by 2G-to-3G handover based on the load or service if the 3G system
load is high.
The procedure is described as follows:
1. When the RNC sends a RELOCATION REQUEST ACKNOWLEDGE message to the 3G CN,
If the switch SndLdInfo2GsmInd(BSC6900,BSC6910) is set to ON, the RELOCATION
REQUEST ACKNOWLEDGE message includes the New BSS To Old BSS Information IE,
which includes the load information of the 3G target cell.
If the switch SndLdInfo2GsmInd(BSC6900,BSC6910) is set to OFF, the RELOCATION
REQUEST ACKNOWLEDGE message does not include the New BSS To Old BSS
Information IE.
2. Depending on the network requirement, the 2G network decides whether to use the load
information sent to the 3G network for judgment.
3. When the RNC receives the RELOCATION REQUEST message from the 3G CN,
If the 3G cell is not in the basic congestion state, the RNC continues the inter-RAT
handover procedure.
If the 3G cell is in the basic congestion state, the RNC returns RELOCATION FAILURE
message to the CN to cancel the inter-RAT handover.
NOTE:
For the concept of "basic congestion", see Load Control Feature Parameter Description.
7 HSPA Handover
7.1 HSDPA Handover
This section describes the WRFD-01061006 HSDPA Mobility Management feature.
Handling of Event 1B
After receiving an event 1B report, the RNC determines whether to delete a cell.
If the cell to be deleted is not an HSDPA serving cell, the cell is directly removed.
Handling of Event 1C
After receiving an event 1C report, the RNC decides whether to change the worst cell.
If the cell to be replaced is not an HSDPA serving cell, the cell is directly removed.
Handling of Event 1D
If experiencing uplink out-of-synchronization, the HSDPA serving cell is changed and its serving link is
removed when the link restoration timer (RlRstrTmr(BSC6900,BSC6910)) expires.
The RESERVED_SWITCH_1_BIT29 switch under RsvSwitch1(BSC6900,BSC6910) in the SET
UALGORSVPARA command controls whether a cell change to the HSDPA target cell is allowed if the
HSDPA target cell is in uplink out-of-synchronization state.
When the switch is turned on, the cell change is prohibited.
As shown in Figure 7-2, when the UE moves from cell 1 (an HSDPA cell) to cell 2 (an R99 cell),
the inter-frequency handover conditions are met and event 2B is triggered. The RNC makes a
handover decision for HSDPA services according to the neighboring cell measurement report,
and reconfigures the service onto the DPCH of cell 2.
Figure 7-2 Inter-frequency handover from an HSDPA cell to an R99 cell
As shown in Figure 7-3 when the UE moves from cell 2 (an R99 cell) to cell 1 (an HSDPA cell),
the inter-frequency handover conditions are met and event 2B is triggered. The RNC hands over
the UE to the DPCH first, and then to the HS-PDSCH if the service can be carried on the HS-
PDSCH.
Figure 7-3 Inter-frequency handover from an R99 cell to an HSDPA cell
As shown in Figure 7-4 when the UE moves from cell 1 (an HSDPA cell) to cell 2 (an HSDPA
cell) and the inter-frequency handover conditions are met, the UE is handed over from cell 1 to
cell 2. The target cell becomes the new serving HS-PDSCH cell.
If the serving or target cell is in load congestion when the UE performs a serving cell update for
inter-frequency or inter-RAT handover, the service is reconfigured from the HS-PDSCH to the
DPCH.
The hard handovers of an HSDPA cell are the same as those of an R99 cell.
Figure 7-4 Inter-frequency handover between HSDPA cells
After deciding that a cell can be added to the E-DCH active set,
If the admission in the downlink fails, the cell is added to neither the E-DCH active set nor the
DCH active set. It waits for the next event 1A report for retry.
Otherwise, if the admission in the downlink succeeds, the RNC perform the HSUPA admission in
the uplink.
If HSUPA admission in the uplink succeeds, the cell is added to the E-DCH active set and
the DCH active set.
If HSUPA admission in the uplink fails, the cell is added only to the DCH active set. If the
DCH admission in the uplink still fails, the cell is added to neither the E-DCH active set nor the
DCH active set. It waits for the next event 1A report for retry.
Handling of Event 1B
If the number of radio links in the DCH active set is larger than one, then:
If the cell to be removed is not an HSUPA serving cell, the cell is directly removed.
Whether the cells under the adjacent RNC support CS Voice over HSPA is determined by the
RNC-level parameter CSVoiceoverHSPASuppInd(BSC6900,BSC6910).
After the best cell of a UE changes, if the size of the DCH or E-DCH active set of the new best
cell is different from those of the old best cell, the RNC removes or reconfigures radio links to
adapt to the size and configuration of the new best cell.
Handling of Event 1C
When event 1C is triggered, the UE reports the event-triggered list that contains good cells and
the cells to be replaced, and sequences the cells from the highest to the lowest quality according
to measurement quantity.
After receiving the measurement report, the RNC proceeds as follows:
If the new cell supports HSUPA, then:
If the current number of cells in the E-DCH active set is smaller than the value
of MaxEdchCellInActiveSet(BSC6900,BSC6910), the new cell is added to the E-DCH active
set.
If the current number of cells in the E-DCH active set is equal to the value
of MaxEdchCellInActiveSet(BSC6900,BSC6910) and the cell to be replaced is also included
in the E-DCH active set, the new cell joins the E-DCH active set through replacement.
If the current number of cells in the E-DCH active set is equal to the value
of MaxEdchCellInActiveSet(BSC6900,BSC6910) and the cell to be replaced is not included
in the E-DCH active set, the new cell is added only to the DCH active set.
If the current service is CS Voice over HSPA and the cell to be removed is an E-DCH serving cell,
then:
If the new best cell supports both HSDPA and HSUPA, the cell is reconfigured to be an
HS-DSCH serving cell or an E-DCH serving cell.
If the new best cell supports HSDPA but not HSUPA, the current service is changed from
CS Voice over HSPA to CS Voice over DCH through the reconfiguration. If there remain other
HSDPA services, the serving cell should be updated and the new best cell should be the HS-
PDSCH serving cell.
If the new best cell supports neither HSUPA nor HSDPA, the current service is
reconfigured to be CS Voice over DCH. If the cell to be removed is an E-DCH serving cell, the
HS-DSCH serving cell must be removed at the same time. Therefore, a new E-DCH serving
cell or HS-DSCH serving cell must be determined. The method is the same as that of removing
the serving cell, as described in the previous section of Handling of Event 1B.
If the new cell does not support HSUPA, the cell is added to only the DCH active set.
Handling of Event 1D
If the criteria for intra-frequency hard handover are fulfilled, the RNC performs intra-frequency
hard handover after receiving the event 1D report. If the criteria for intra-frequency hard
handover are not fulfilled, the RNC performs intra-frequency soft handover based on the
measurement report.
If the uplink service is carried on the E-DCH, then:
If the new best cell in the active set supports HSUPA and the HSPA hysteresis timer
(HspaTimerLen(BSC6900,BSC6910)) expires, the E-DCH serving cell becomes the best cell. The
HSPA hysteresis timer is restarted after the cell change.
If the new best cell in the active set does not support HSUPA,
The uplink service is directed to the DCH through the reconfiguration. If the
reconfiguration fails, the service is still carried on the E-DCH. The UE is connected to the new
best cell only on the DCH.
Triggering of Event 1J
MInAS is the measurement result of the cell in the E-DCH active set with the lowest measurement
result.
H1J is the hysteresis parameter for event 1J and is determined
by Hystfor1J(BSC6900,BSC6910).
If the measurement result is CPICH-Ec/N0, MNew and MInAS are expressed as ratios.
If the measurement result is CPICH-RSCP, MNew and MInAS are expressed in mW.
Figure 7-5 Triggering of event 1J
B: signal quality curve of the worst cell in the E-DCH active set
C: signal quality curve of a cell not in the E-DCH active set but included in DCH active set
D: signal quality curve of a cell not in the E-DCH active set but included in DCH active set
In Figure 7-5, the hysteresis and the cell individual offsets for all cells equal 0.
The first measurement report is sent when primary CPICH D becomes better than primary
CPICH B. The "cell measurement event result" of the measurement report contains the
information of primary CPICH D and CPICH B.
On the assumption that the E-DCH active set has been updated after the first measurement report
(E-DCH active set is now primary CPICH A and primary CPICH D), the second report is sent
when primary CPICH C becomes better than primary CPICH A. The "cell measurement event
result" of the second measurement report shows that primary CPICH C is better than primary
CPICH A in quality.
The following parameters need to be set on the RNC LMT:
Hystfor1J(BSC6900,BSC6910): hysteresis of event 1J
After receiving the intra-frequency measurement report from the UE, the RNC decides whether
to go to the execution phase, depending on the information in the report.
Handling of Event 1J
Event 1J provides the solution to the issue of how to add an HSUPA cell in a DCH active set to
an E-DCH active set. This event is triggered when a non-active E-DCH but active DCH primary
CPICH becomes better than an active E-DCH primary CPICH.
When event 1J is triggered, the UE reports the event-triggered list that contains good cells and
the cells to be replaced, and sequences the cells from the highest to the lowest quality according
to measurement quantity.
After receiving the measurement report, the RNC proceeds as follows:
If the current number of cells in the E-DCH active set is smaller than the value
of MaxEdchCellInActiveSet(BSC6900,BSC6910), the cell where event 1J is triggered is
reconfigured to E-DCH.
If the current number of cells in the E-DCH active set is equal to the value
of MaxEdchCellInActiveSet(BSC6900,BSC6910), the RNC searches the measurement report for
the non-serving Cell_EDCH with the lowest measured quality in the E-DCH active set. Then, the
uplink of the cell where event 1J is triggered is reconfigured from DCH to E-DCH, and the uplink of
CELL-EDCH is reconfigured from E-DCH to DCH.
If experiencing uplink out-of-synchronization, the HSUPA serving cell is changed and its serving
link is removed when the link restoration timer (RlRstrTmr(BSC6900,BSC6910)) expires.
The RESERVED_SWITCH_1_BIT29 switch under RsvSwitch1(BSC6900,BSC6910) in
the SET UALGORSVPARA command controls whether a cell change to the HSUPA target cell
is allowed if the HSUPA target cell is in uplink out-of-synchronization state.
When the switch is turned on, the cell change is prohibited.
For HSUPA, 2 ms TTI and 10 ms TTI are applicable but not all the cells support 2 ms TTI. When
both 2ms-TTI-capable and 2ms-TTI-incapable cells exist in a network, a UE may undergo
handovers between E-DCHs of 10 ms TTI and 2 ms TTI (WRFD-01061404 HSUPA 2ms/10ms
TTI Handover).
Only when all the cells in the E-DCH active set support 2 ms TTI can the services be configured
to the E-DCH with 2 ms TTI. If any cell in the E-DCH active set does not support 2 ms TTI, the
services are configured on the E-DCH with 10 ms TTI.
The detailed principles are as follows:
When the uplink service is carried on the E-DCH with 2 ms TTI, if a cell that supports only 10 ms
TTI is to be added to the E-DCH active set, the source cell undergoes a radio bearer reconfiguration
to 10 ms TTI. A soft handover to the target cell is performed.
Upon each handover, if a radio link needs to be added, removed, or replaced, the RNC judges
whether all the cells in the E-DCH active set and the UE support 2 ms TTI.
If they all support 2 ms TTI and the uplink service is currently carried on the E-DCH with 10 ms
TTI, the RNC reconfigures the service to the E-DCH with 2 ms TTI.
If the reconfiguration fails, a timer is started for periodic retries to the E-DCH with 2 ms
TTI.
If the handover is performed before the timer expires, the timer is stopped.
After the handover, the RNC decides whether to start the timer, based on the handover
result.
Scenario 1
Scenario 2
Scenario 3
If the current service is CS Voice over HSPA and the target cell supports both HSDPA and HSUPA, the
target cell is reconfigured as an HSPA serving cell. Otherwise, the service of CS Voice over HSPA must
first be reconfigured as CS Voice over DCH.
Whether the target RNC supports CS Voice over HSPA is determined by the
parameter CSVoiceOverHspaSuppInd(BSC6900,BSC6910).
Scenario 1: Inter-Frequency Handover from an HSUPA Cell to Another HSUPA Cell
Assume that the UE moves from HSUPA cell 1 to HSUPA cell 2 and that the two cells are inter-
frequency neighboring cells, as shown in Figure 7-6.
Figure 7-6 Inter-frequency handover from an HSUPA cell to another HSUPA cell
During this procedure, event 2B is triggered. The HSUPA admission request is made for the
target cell by the RNC.
If the request is accepted, the handover is performed through the physical channel
reconfiguration message.
If the request is rejected, the RB reconfiguration is implemented, and the services on the E-DCH
are reconfigured for the DCH.
Assume that the UE moves from HSUPA cell 1 to non-HSUPA cell 2 and that the two cells are
inter-frequency neighboring cells, as shown in Figure 7-7.
Figure 7-7 Inter-frequency handover from an HSUPA cell to a non-HSUPA cell
During this procedure, event 2B is triggered, and the target cell does not support HSUPA. The
DCH admission request is made for the target cell. If the request is accepted, the RB
reconfiguration is implemented, and the services on the E-DCH are reconfigured for the DCH.
Scenario 3: Inter-Frequency Handover from a Non-HSUPA Cell to an HSUPA Cell
Assume that the UE moves from non-HSUPA cell 1 to HSUPA cell 2 and that the two cells are
inter-frequency neighboring cells, as shown in Figure 7-8.
Figure 7-8 Inter-frequency handover from a non-HSUPA cell to an HSUPA cell
7.3.1 Overview
The basic mechanisms of handover remain unchanged after the introduction of HSPA+. New functions
are added to handle the scenario where the source cell and target cell support different HSPA+
technologies or where admission control prevents the UE from using the preferred technologies.
Whether a neighboring cell supports HSPA+ technologies can be set through the
parameter CellCapContainerFdd(BSC6900,BSC6910).
Figure 7-9 shows the procedure of HSPA+ technology configuration.
Figure 7-9 Procedure of HSPA+ technology configuration
The target cell does not support HSDPA or HSUPA but has a DRD neighboring cell.
If the admission fails during the reconfiguration, the timer
(ChannelRetryHoTimerLen(BSC6900,BSC6910)) is started. Periodic retries to HS-DSCH or E-DCH are
performed.
8 HCS Handover
8.1 Overview
HCS handover (WRFD-021200 HCS) is one type of inter-frequency handover and inter-RAT handover.
HCS handover is based on UE speed estimation, and is also called speed-based handover.
In a 3G network, hot spots in radio communication may appear with the increase of subscribers and
traffic. This requires more cells to increase the network capacity. More cells and smaller cell radius lead to
more frequent handovers of UEs. For a UE in fast movement, frequent handovers reduce call quality,
increase uplink interference, and increase signaling load. Here, Hierarchical Cell Structure (HCS) is a
mechanism that arranges different cells at different layers, each layer granted a priority. HCS handover
instructs UEs to stay at cells with different priorities based on speed estimation, increasing the network
capacity.
Figure 8-1 shows an HCS example with three layers.
Figure 8-1 HCS with three layers
Micro cell
Densely populated areas
High requirement for capacity
Slow-moving environment
Pico cell
Indoor coverage
Outdoor blind spot coverage
Slow-moving environment
The pico cell has the highest HCS priority but the smallest coverage and the macro cell has the lowest
HCS priority but the largest coverage.
Based on speed estimation, the RNC instructs a fast-moving UE to select a cell with a lower HCS priority
to decrease the frequency of handovers, and instructs a slow-moving UE to select a cell with a higher
HCS priority to increase the network capacity.
RNC supports the HCS with eight priorities. The priority level of a cell is set by
the HCSPrio(BSC6900,BSC6910) parameter.
To allow HCS handover, the RNC must enable the function through
the HoSwitch(BSC6900,BSC6910): HO_ALGO_HCS_SPEED_EST_SWITCH parameter.
8.2 HCS Handover Procedure
HCS handover is based UE speed estimation. Figure 8-2 shows HCS handover procedure.
Figure 8-2 HCS handover procedure
NOTE:
A UE can report the UE Mobility State Indicator IE only in the networks complying with 3GPP
Release 7 or later.
For details about speed estimation and cell reselection parameters for the UEs in idle mode or in
the CELL_PCH/URA_PCH state, see the UE Behaviors in Idle Mode Feature Parameter
Description.
After UE enters CELL_DCH state from CELL_PCH/URA_PCH or idle state, based on the number of
changes of the best cell within a specified period, the speed estimation algorithm estimates the moving
speed of the UE. Then, the RNC decides the UE speed.
The procedure for high-speed estimation is as follows:
If HoSwitch(BSC6900,BSC6910): HO_ALGO_HCS_SPEED_EST_SWITCH is set to ON and
the cell has an HCS priority that is not the lowest, the RNC initiates a high-speed estimation for the
UE after receiving an event 1D report.
If the number of changes of the best cell for the UE is higher than
the NFastSpdEst(BSC6900,BSC6910) within the TFastSpdEst(BSC6900,BSC6910), the RNC
decides that the UE is in fast movement.
The procedure for low-speed estimation is as follows:
If the HoSwitch(BSC6900,BSC6910): HO_ALGO_HCS_SPEED_EST_SWITCH is set
to ON and the cell has an HCS priority that is not the highest, the RNC starts the
timerTCycleSlow(BSC6900,BSC6910) after the RRC connection is set up.
When the timer TCycleSlow(BSC6900,BSC6910) expires, the RNC initiates a low-speed
estimation for the UE.
If the number of changes of the best cell for the UE is lower than
the NSlowSpdEst(BSC6900,BSC6910) within the TSlowSpdEst(BSC6900,BSC6910), the RNC
decides that the UE is in slow movement.
If frequent changes of the best cell occur, several events 1D for the same cell may be recorded. This may
lead to inaccurate UE speed estimation. Therefore, a mechanism is used for anti-ping-pong event 1D
recording.
During the recent period specified by TRelateLength(BSC6900,BSC6910), if multiple event 1Ds
are reported for a certain cell, only the first one is recorded.
In inter-RAT HCS handover, event 3C takes only GSM RSSI as measurement quantity.
Triggering of Event 2C
When the signal quality of a non-used frequency is above a certain threshold, the UE reports event 2C to
the RNC.
After the conditions of event 2C are fulfilled and maintained until the
parameter TrigTime2C(BSC6900,BSC6910) is reached, the UE reports the event 2C measurement
report message.
Event 2C is triggered on the basis of the following formula:
QNoused TNoused2c + H2c/2
where
QNoused is the measured quality of the cell that uses the other frequencies.
TNoused2c is the absolute quality threshold of the cell that uses the other frequencies,
namely, InterFreqNCovHOThdEcN0(BSC6900,BSC6910).
H2c is the event 2C hysteresis value Hystfor2C(BSC6900,BSC6910).
If the UE is in slow movement, the RNC instructs the UE to select a cell with a higher HCS
priority.
If the UE is in normal movement, no inter-layer handover occurs.
When the RNC instructs the UE to select a cell with a lower or higher HCS priority, the neighboring cells
whose frequency band is not supported by the UE are not taken into account. If there are neighboring
cells with several candidate frequencies, the RNC selects one of the frequencies randomly.
If the best cell changes, the high-speed estimation for the UE is triggered.
QoS problem caused by the quality imbalance between uplink and downlink
9 Blind Handover
9.1 Overview
There are two types of blind handover: emergent blind handover and non-emergent blind handover.
Emergent blind handover is triggered by 1F event that indicates the used frequency becomes
worse. The UE must perform emergent handover to avoid call drops.
Non-emergent blind handover may be triggered by LDR, DRD, or HCS speed estimation.
For details about LDR and DRD, see Load Control Feature Parameter Description.
For details about HCS speed estimation, see chapter 8 HCS Handover
The parameter BlindHoFlag(BSC6900,BSC6910) is configured for neighboring cells and determines
whether a blind handover to this cell is allowed.
The BlindHoFlag(BSC6900,BSC6910) parameter in the ADD UINTERFREQNCELL command and
the BlindHoFlag(BSC6900,BSC6910) parameter in the ADD U2GNCELL command specify whether a
cell is considered as a candidate cell for inter-frequency or inter-RAT blind handover, respectively.
The parameter BlindHOPrio(BSC6900,BSC6910) indicates the blind handover priority of the cell. The
value 0 represents the highest priority.
Currently, Huawei does not support inter-RNC blind handovers.
NOTE:
Inter-frequency and inter-RAT blind handovers are also controlled by the inter-frequency and inter-RAT
handover switches in addition to the blind handover switch. When the inter-frequency or inter-RAT
handover switch is not turned on, an inter-frequency or inter-RAT blind handover cannot be performed
after event 1F is received.
1. The RNC gets the actual best cell from event 1F. If the quality of the best cell meets the blind
handover condition, that is the quality of the best cell is larger than or equal
toBlindHORSCP1FThreshold(BSC6900,BSC6910), the RNC gets neighboring cells for blind
handover of the best cell, and filtrates the cells that belong to the frequency bands that UEs do not
support. If the quality of the best cell is lower
than BlindHORSCP1FThreshold(BSC6900,BSC6910), the UE is at the edge of the network
coverage and the blind handover is not allowed.
2. If there are multiple neighboring cells for blind handover, the RNC chooses the cell must support
all the current services of UE. When there are multiple such cells, the RNC choose the neighboring
cell for blind handover randomly.
If any inter-frequency cell does not meet the above conditions, then the RNC chooses the inter-RAT cells
with the highest priority of blind handover. The blind handover priority of the cell is specified by the
parameter BlindHOPrio(BSC6900,BSC6910)..
If an inter-frequency blind handover based on event 1F fails, the RNC takes the same penalty measures
as those for an inter-frequency handover failure. For details, see section 5.8.1 Inter-Frequency Handover
Failure
10 Handover Protection
10.1 Anti-Ping-Pong
Inter-Frequency Anti-Ping-Pong
For the 2G-to-3G handover, the measurement control message is delivered through a system
information broadcast of 2G when the 2G cell has a neighboring 3G cell. The dual-mode MS
performs the inter-RAT measurement in idle timeslots and reports the measurement result. Based
on the reported measurement values, the BSC decides whether to perform the handover to the 3G
network.
To avoid the ping-pong handover between 2G and 3G, the 2G-to-3G handover penalty algorithm
is used.
When the UE is handed over from 2G to 3G and if any CS domain service exists, the system
increases the hysteresis of event 3A through the
parameterInterRATPingPongHyst(BSC6900,BSC6910) to prevent the UE from the ping-
pong handover between 2G and 3G in the period specified by the
parameterInterRATPingPongTimer(BSC6900,BSC6910). During the penalty time, the
previous periodical report will be changed to the event 3A report. The value 0 indicates that the
system does not take measures to avoid ping-pong handover between 2G and 3G networks.
After the retry timer expires, the UE makes a handover attempt to the cell again until the number
of retry times exceeds the maximum number of retry times. If the handover succeeds or two new
event 2B reports are received, the periodical retry is stopped.
For the inter-frequency handover based on coverage or QoS, the following two parameters determine the
retry period and the maximum number of retry times:
Retry timer: PeriodFor2B(BSC6900,BSC6910)
For CS services or CS and PS combined services, the HANDOVER FROM UTRAN signaling
procedure on the Uu interface is performed only when the handover based on CS services is made.
For a PS service or combined PS services, the CELL CHANGE ORDER FROM UTRAN or
HANDOVER FROM UTRAN signaling procedure on the Uu interface is performed.
If the HANDOVER FROM UTRAN FAILURE or CELL CHANGE ORDER FROM UTRAN
FAILURE message is received, the handover on the Uu interface fails.
If the "Inter-RAT handover failure cause" in HANDOVER FROM UTRAN FAILURE message
is "Configuration unacceptable", or if the "Inter-RAT change failure cause" in CELL CHANGE
ORDER FROM UTRAN FAILURE message is "Configuration unacceptable", the RNC does not
make a handover retry to the cell.
Otherwise, the related retry timer for the cell is started. After the retry timer expires, the UE
makes a handover attempt to the cell again until the number of retry times exceeds the maximum
number of retry times.
If the handover succeeds or the new event 3A or 3C report is received, the periodical retry is
stopped.
Compared with the traditional speech service of the GSM, the VP service of the UMTS can
transmit not only speech services between the calling party and the called party, but also the
images and videos captured by both parties. Since the actual implementation is limited by
terminals and networks, the VP service sometimes carries only speech and may fail to transmit
images or videos. In this scenario, the Service Change and Unrestricted Digital Information
Fallback (SCUDIF) provide the fallback mechanism that changes a video call to a common
speech call.
As specified in section 4.3 Core Network procedure in 3GPP TS 23.172 V10.0.0, the fallback
service of the VP is categorized into the following two types:
The process of changing multimedia services back to speech services during call setup. The
RNC does not take part in the process. Therefore, the detailed description of fallback process is not
given.
The process of changing multimedia services back to speech services during the call.
Currently, the network-initiated multimedia fallback is performed only for the 3G-to-2G
handover. Service changes triggered by the UEs are not supported.
Fallback is initiated when both of the following occasions are met:
The RNC decides to send an inter-RAT handover request after receiving periodical measurement
reports of event 1A, 3A, or 3C.
The service is combined with a VP, and the "Alternative RAB Parameters" in the RAB
ASSIGNMENT message is a valid AMR speech format.
Figure 10-1 shows the service change procedure for the 3G-to-2G handover. The network
initiates the service change, that is, the RNC initiates the change from the VP service to the
speech service during the call.
Figure 10-1 Service change procedure for the 3G-to-2G handover in the CS domain
1. The CN sends the SRNC a RANAP RAB ASSIGNMENT REQUEST message to set up the VP
service.
2. During 3G-to-2G handover, the SRNC sends a RANAP RAB MODIFY REQUEST message to
change the VP service to the AMR speech service. In the section 9.1.46 RAB MODIFY REQUEST
and 9.2.1.45 Requested RAB Parameter Values in 3GPP TS 25.413 V6.5.0, the information
element (IE) Alternative RAB Configuration Request is also added to the RAB MODIFY REQUEST
message, which enables the RNC to request the CN to change the VP service to the AMR speech
service.
3. The MSC initiates the Bearer Capability (BC) negotiation with the UE.
4. After the negotiation, the RNC is requested to perform service change.
When the multimedia fallback ends, the RNC decides whether to perform the 3G-to-2G
handover according to the current measurements reported by the UE.
The CN initiates the RAB reconfiguration to request both parties to perform the multimedia
fallback. The single VP service falls back to the single AMR speech service. The multi-RAB
service combined with VP falls back to the multi-RAB service combined with AMR. If the
multimedia fallback succeeds, that is, the video phone in the service falls back to speech
successfully, the inter-RAT handover is initiated. Otherwise, the inter-RAT handover fails.
ReportIntervalfor1C(BSC6900,BSC6910)
ReportIntervalfor1J(BSC6900,BSC6910)
The following parameters specify the number of reporting times of events for periodical reporting:
PeriodMRReportNumfor1A(BSC6900,BSC6910)
PeriodMRReportNumfor1C(BSC6900,BSC6910)
PeriodMRReportNumfor1J(BSC6900,BSC6910)
When the actual reporting times exceed the set value, the periodical reporting ends.
NOTE:
When the number of configured intra-frequency neighboring cells exceeds 32,
the HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH andHO_INTRA_FREQ_DETSET_RPRT_S
WITCH switches of the HoSwitch(BSC6900,BSC6910) parameter must be turned on. Otherwise, the
RNC will not select these extra intra-frequency neighboring cells as candidate target cells.
NOTE:
When the number of configured intra-frequency neighboring cells exceeds 32,
the HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH andHO_INTRA_FREQ_DETSET_RPRT_S
WITCH switches of the HoSwitch(BSC6900,BSC6910) parameter must be turned on. Otherwise, the
RNC will not select these extra intra-frequency neighboring cells as candidate target cells.
13 Compressed Mode
13.1 Overview
Compressed mode control is a mechanism whereby certain idle periods are created in radio frames
during which the UE can perform measurements on other frequencies. The UE must use the compressed
mode if the UE needs to measure the pilot signal strength of an inter-frequency cell or inter-RAT cell and
has a single-frequency receiver only.
Figure 13-1 Compressed mode
SF/2
The RNC automatically determines the type of compressed mode on the basis of the spreading factor
used in the uplink or the downlink.
When the downlink spreading factor is greater than or equal to the
parameter DlSFTurnPoint(BSC6900,BSC6910), the SF/2 approach is preferred. Otherwise, the
high layer scheduling is used.
When the uplink spreading factor is greater than or equal to the
parameter UlSFTurnPoint(BSC6900,BSC6910), the SF/2 approach is preferred. Otherwise, the
high layer scheduling is used.
Inter-RAT measurement
The value of the IE "Adjacent frequency measurements without compressed mode" reported by
the UE is TRUE.
For a UE that supports DC-HSDPA/DC-HSUPA:
If the UE has a DC-HSDPA/DC-HSUPA service, all the cells involved in inter-frequency
measurement are at the same frequency as the secondary carrier.
If the UE does not have a DC-HSDPA/DC-HSUPA service, all the cells involved in inter-
frequency measurement are at the same frequency, with a 5 MHz spacing from the current
cell, but within the same band as the current cell.
If a UE that supports DC-HSDPA/DC-HSUPA does not meet the preceding conditions, it needs
to perform inter-frequency or inter-RAT measurement in compressed mode. In this case, the
same sequence and type of compressed mode are required by the primary and secondary
carriers.
Each physical frame can provide three to seven timeslots for the inter-frequency or inter-RAT cell
measurement.
If the parameter is set to Limited, the reconfiguration from E-DCH to DCH is required before
compressed mode is activated. HSUPA UEs perform neighboring cell measurement in compressed
mode. In addition, HSUPA services cannot be established when compressed mode is activated.
If the parameter is set to BasedOnUECap, the RNC determines whether to perform E2D
procedure before compressed mode activated based on the UE capability.
HSPA+ Compatibility
14 Related Features
14.1 WRFD-01061006 HSDPA Mobility Management
Prerequisite Features
The intra-frequency handover function in this feature requires at least one of the following
features:
WRFD-020201 Intra NodeB Softer Handover
WRFD-020202 Intra RNC Soft Handover
WRFD-020203 Inter RNC Soft Handover
The inter-frequency handover function in this feature requires the WRFD-020302 Inter Frequency
Hard Handover Based on Coverage feature.
The inter-RAT handover function in this feature requires the WRFD-020303 Inter-RAT Handover
Based on Coverage feature.
None
Impacted Features
The intra-frequency handover function in this feature requires at least one of the following
features:
WRFD-020201 Intra NodeB Softer Handover
WRFD-020202 Intra RNC Soft Handover
WRFD-020203 Inter RNC Soft Handover
The inter-frequency handover function in this feature requires the WRFD-020302 Inter Frequency
Hard Handover Based on Coverage feature.
The inter-RAT handover function in this feature requires the WRFD-020303 Inter-RAT Handover
Based on Coverage feature.
Impacted Features
None
Impacted Features
None
None
Impacted Features
None
15 Network Impact
15.1 WRFD-020302 Inter Frequency Hard Handover Based on Coverage
No impact.
Network Performance
The HSDPA Mobility Management feature implements all types of handovers between adjacent cells. This
provides continuous coverage and better service quality for HSDPA UEs.
RAN16.0 introduces the fast HSDPA serving cell change function, which has the following impacts on
network performance:
The delay of HSDPA serving cell change is shortened by about 400 ms. (The delay of HSDPA
serving cell change is the interval between the time when the RNC sends the PH CH RECFG
message and the time when the RNC receives the PH CH RECFG CMP message.)
The HSDPA throughput is increased by 10% to 15%.
The success rate of HSDPA serving cell changes is increased by 5% to 10%.
16 Engineering Guidelines
16.1 WRFD-020201 Intra Node B Softer Handover
This section describes how to activate, verify, and deactivate the basic feature WRFD-020201 Intra
NodeB Softer Handover.
16.1.1 Requirements
Dependencies on Hardware
Not supported by Micro base stations.
Dependencies on Other Features
This feature does not depend on other features.
License
This feature is not under license control.
16.1.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches). In this step,
selectHO_INTRA_FREQ_SOFT_HO_SWITCH under HandOver Switch to enable soft handover.
2. Run the RNC MML command SET UHOCOMM (CME single configuration: UMTS Radio Global
Configuration Express > HandOver Parameter Configuration > RNC Oriented Handover Algorithm
Common Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
set Softer handover combination indicator switch to MAY or MUST.
3. Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell; CME batch
modification center: not supported) to add an intra-frequency neighboring cell.
4. Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented Intra-
frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set the parameter related to handover.
16.1.5 Deactivation
Run the RNC MML command SET UHOCOMM (CME single configuration: UMTS Radio Global
Configuration Express > HandOver Parameter Configuration > RNC Oriented Handover Algorithm
Common Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
set Softer handover combination indicator switch to MUST_NOT.
16.2.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
This feature is not under license control.
16.2.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to enable soft handover.
2. Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell; CME batch
modification center: not supported) to add an intra-frequency neighboring cell.
3. Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented Intra-
frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set the parameter related to handover.
16.2.3 MML Command Examples
//Activating Intra RNC Soft Handover
SET UCORRMALGOSWITCH: HoSwitch=HO_INTRA_FREQ_SOFT_HO_SWITCH-1;
ADD UINTRAFREQNCELL: RNCId=202, CellId=2381, NCellRncId=203, NCellId=3291,
SIB11Ind=TRUE, SIB12Ind=FALSE, TpenaltyHcsReselect=D0, NPrioFlag=FALSE;
SET UINTRAFREQHO: FilterCoef=D3, IntraFreqMeasQuantity=CPICH_EC/N0,
PeriodMRReportNumfor1C=D16, ReportIntervalfor1C=D4000;
16.2.5 Deactivation
Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS Radio
Global Configuration Express > Connection_Oriented RRM Switch Configuration > Connection Oriented
Algorithm Switches; CME batch modification center: Modifying RNC Parameters in Batches) to set Softer
handover combination indicator to disable the soft handover.
16.3.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
This feature is not under license control.
Other Requirements
The Iur interface is configured between adjacent RNCs.
16.3.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to enable soft handover.
2. Run the RNC MML command ADD UNRNC (CME single configuration: IUR Configuration
Express > Neighbouring RNC > Neighboring RNC; CME batch modification center: not supported)
or MOD UNRNC (CME single configuration: IUR Configuration Express > Neighbouring RNC >
Neighboring RNC; CME batch modification center: not supported) to enable cross-Iur soft
handover.
3. Run the RNC MML command ADD UEXT3GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
3G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) to add a neighboring RNC cell.
4. Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell; CME batch
modification center: not supported) to add an intra-frequency neighboring cell.
5. Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented Intra-
frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set the parameter related to handover.
16.3.5 Deactivation
Run the RNC MML command MOD UNRNC (CME single configuration: IUR Configuration Express >
Neighbouring RNC > Neighboring RNC; CME batch modification center: not supported) to disable the
cross-Iur soft handover.
16.3.6 MML Command Examples
//Deactivating Inter RNC Soft Handover
MOD UNRNC: NRncId=1, SHOTRIG=CS_SHO_SWITCH-0&HSPA_SHO_SWITCH-
0&NON_HSPA_SHO_SWITCH-0;
16.4.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
This feature is not under license control.
16.4.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to select HO_INTRA_FREQ_HARD_HO_SWITCH from the HandOver
switch list.
2. Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell; CME batch
modification center: not supported) to add an intra-frequency or inter-RNC neighboring cell.
3. If cross-Iur hard handover is required, add the neighboring RNC and neighboring RNC cell. Run
the RNC MML command ADD UNRNC (CME single configuration: IUR Configuration Express >
Neighbouring RNC > Neighboring RNC; CME batch modification center: not supported) to add a
neighboring RNC. Run the RNC MML commandADD UEXT3GCELL (CME single configuration:
Object Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 3G External Cell; CME batch modification center: Modifying RNC External
Cell Parameters in Batches) to add a neighboring RNC cell. Run the RNC MML command ADD
UINTRAFREQNCELL (CME single configuration: UMTS Cell Configuration Express > Neighboring
Cell > Intra-frequency Neighboring Cell; CME batch modification center: not supported) to set the
neighboring relationships.
4. Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented Intra-
frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set the parameter related to handover.
16.4.5 Deactivation
Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS Radio
Global Configuration Express > Connection_Oriented RRM Switch Configuration > Connection Oriented
Algorithm Switches; CME batch modification center: Modifying RNC Parameters in Batches) to
deselect HO_INTRA_FREQ_HARD_HO_SWITCH from the Handover switch list.
16.5.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
The feature WRFD-010612 HSUPA Introduction Package must be configured before this feature is
activated.
License
The license "High Speed Uplink Packet Access" on the RNC side has been activated. The license "
the number of NodeBs with HSUPA function enabled" on the NodeB side has been activated. For
details about the license items and how to activate the license, see License Management Feature
Parameter Description.
16.5.2 Activation
The methods of activating intra-frequency, inter-frequency, and inter-RAT handovers are the same for
HSUPA users and R99 users. For the activation procedures for configuring HSUPA Mobility Management,
see the following sections:
16.4 WRFD-020301 Intra Frequency Hard Handover
16.5.4 Deactivation
This feature does not need to be deactivated.
16.6.1 Requirements
Dependencies on Hardware
Dependencies on RNC Hardware
This feature does not depend on the RNC hardware.
Dependencies on NodeB Hardware
The BTS3812E, BTS3812A, or BTS3812AE is configured with the EBBI, EBOI, EULP, or
EULPd board.
The BBU3806 is configured with the EBBC or EBBCd board.
The BBU3900 is configured with the WBBPb or WBBPd board.
16.6.2 Activation
This feature is license controlled. It takes effect after its license is activated. For details about how to
activate the license, see License Management Feature Parameter Description.
16.6.4 Deactivation
This feature does not need to be deactivated.
16.7.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
The license "Hierarchical Cell Structure" on the RNC side has been activated. For details about the
license items and how to activate the license, see License Management Feature Parameter
Description.
Other Requirements
To enable videophone services to fall back to voice services, the MSC and UE must comply with
3GPP Release 6. For details, see section 4.3 Core Network procedure in 3GPP TS 23.172 V10.0.0.
16.7.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches).
In this step, select the following check boxes under the HoSwitch(BSC6900,BSC6910) parameter:
HO_ALGO_HCS_SPEED_EST_SWITCH
HO_INTRA_FREQ_SOFT_HO_SWITCH
HO_INTER_FREQ_HARD_HO_SWITCH
HO_INTER_RAT_PS_OUT_SWITCH
HO_INTER_RAT_CS_OUT_SWITCH
In this step, select the CMP_DL_LOAD_BALANCE_SWITCH check box under
the Compatibility Switch2 parameter.
2. Run the RNC MML command ADD UCELLHCS (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell HCS Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches). In this step, set Use of HCS to USED.
3. Set the HCS parameters for different types of neighboring cells as follows:
Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell;
CME batch modification center: not supported) to add an intra-frequency neighboring cell and
set the HCS parameters.
Run the RNC MML command ADD UINTERFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Inter-frequency Neighboring Cell;
CME batch modification center: not supported) to add an inter-frequency neighboring cell and
set the HCS parameters.
Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification
center: not supported) to add an inter-RAT neighboring GSM cell and set the HCS
parameters.
4. For the cells whose HCS parameters have been set, run the RNC MML command ADD
UCELLHCSHO (CME single configuration: UMTS Cell Configuration Express > Cell Parameters >
Cell Oriented HCS Handover Algorithm Parameters; CME batch modification center: Modifying
UMTS Cell Parameters in Batches). In this step, setSpdEstSwitch to ON.
5. Run the RNC MML command SET UHCSHO (CME single configuration: UMTS Radio Global
Configuration Express > HandOver Parameter Configuration > RNC Oriented HCS HO Algorithm
Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to set the
RNC-level HCS parameters according to network plan.
16.7.5 Deactivation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches). In this step, deselectHO_ALGO_HCS_SPEED_EST_SWITCH from
the HoSwitch parameter.
2. Run the RNC MML command MOD UCELLHCS (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell HCS Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches). In this step, set Use of HCS to NOT_USED.
3. Run the RNC MML command MOD UCELLHCSHO (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell Oriented HCS Handover Algorithm Parameters;
CME batch modification center: Modifying UMTS Cell Parameters in Batches). In this step,
set SpdEstSwitch to OFF.
16.8.3 Requirements
Dependencies on Hardware
This feature does not depend on the hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
The license "Inter frequency hard handover" on the RNC side has been activated. For details about
the license items and how to activate the license, see License Management Feature Parameter
Description.
Other Requirements
The UE supports relevant measurements and the handover procedure.
16.8.4 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches). In this step, selectHO_INTER_FREQ_HARD_HO_SWITCH from
the HandOver Switch drop-down list.
2. Run the RNC MML command ADD UINTERFREQNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > Inter-frequency Neighboring Cell; CME batch
modification center: not supported) to add an inter-frequency neighboring cell.
3. Run the RNC MML command ADD UCELLINTERFREQHOCOV (CME single configuration:
UMTS Cell Configuration Express > Cell Parameters > Cell Oriented Coverage Based Inter-
frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERFREQHOCOV (CME single configuration: UMTS Radio Global Configuration Express >
HandOver Parameter Configuration > RNC Oriented Coverage Based Inter-frequency Handover
Measurement Algorithm Parameters; CME batch modification center: Modifying RNC Parameters
in Batches) (RNC level) to configure parameters related to coverage-based inter-frequency hard
handover.
5. After the event 2D measurement report is reported, check whether the RNC has sent the UE
an RRC_MEAS_CTRL message and the traced message contains the information element
interFrequencyMeasurement, as shown in Figure 16-2.
Figure 16-2 Inter-frequency measurement control message
6. After the inter-frequency measurement control message is reported, check whether the RNC has
sent the UE an RRC_PH_CH_RECFG message, and the UE has sent the RNC
RRC_PH_CH_RECFG_CMP message, as shown in Figure 16-3 and Figure 16-4.
Figure 16-3 Physical channel reconfiguration message
Figure 16-4 Physical channel reconfiguration complete message
16.8.7 Deactivation
Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS Radio
Global Configuration Express > Connection_Oriented RRM Switch Configuration > Connection Oriented
Algorithm Switches; CME batch modification center: Modifying RNC Parameters in Batches). In this step,
deselect HO_INTER_FREQ_HARD_HO_SWITCH fromHandOver Switch.
VS.RRC.MrRpt.2D
VS.HHO.AttInterFreqOut.CS.TrigRscp
VS.HHO.AttInterFreqOut.CS.TrigEcNo
VS.HHO.AttInterFreqOut.PS.TrigRscp
VS.HHO.AttInterFreqOut.PS.TrigEcNo
When a UE is located at the cell edge, it reports event 2D to trigger a coverage-based inter-frequency or
inter-RAT hard handover.
If the value of the VS.RRC.MrRpt.2D counter is small, the number of coverage-based inter-
frequency hard handovers triggered in a measurement period is small, which indicates that the gains
provided by this feature are not obvious.
If the value of the counter is large and is similar to the value of
the VS.HHO.AttInterFreqOut.CS.TrigRscp,
VS.HHO.AttInterFreqOut.CS.TrigEcNo,VS.HHO.AttInterFreqOut.PS.TrigRscp,
or VS.HHO.AttInterFreqOut.PS.TrigEcNo counter, the inter-frequency hard handovers that
happened in the measurement period are mainly coverage-based inter-frequency hard handovers,
which indicates that the gains provided by this feature are obvious.
If the value of the counter is large and is much greater than the value of
the VS.HHO.AttInterFreqOut.CS.TrigRscp,
VS.HHO.AttInterFreqOut.CS.TrigEcNo,VS.HHO.AttInterFreqOut.PS.TrigRscp,
or VS.HHO.AttInterFreqOut.PS.TrigEcNo counter, both coverage-based inter-frequency hard
handovers and coverage-based inter-RAT hard handovers happened in the measurement period.
16.9.3 Requirements
Dependencies on Hardware
This feature does not depend on the hardware.
Dependencies on Other Features
The feature WRFD-020302 Inter Frequency Hard Handover Based on Coverage must be configured
before this feature is activated.
License
The license "Inter Frequency Hard Handover Based on DL QoS " on the RNC side has been
activated. For details about the license items and how to activate the license, seeLicense
Management Feature Parameter Description.
16.9.4 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to activate the inter-frequency hard handover.
2. Run the RNC MML command ADD UINTERFREQNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > Inter-frequency Neighboring Cell; CME batch
modification center: not supported) to add an inter-frequency neighboring cell.
3. Run the RNC MML command ADD UCELLINTERFREQHOCOV (CME single configuration:
UMTS Cell Configuration Express > Cell Parameters > Cell Oriented Coverage Based Inter-
frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERFREQHOCOV (CME single configuration: UMTS Radio Global Configuration Express >
HandOver Parameter Configuration > RNC Oriented Coverage Based Inter-frequency Handover
Measurement Algorithm Parameters; CME batch modification center: Modifying RNC Parameters
in Batches) (RNC level) to configure parameters related to DL-QoS-based inter-frequency hard
handover.
4. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
activate inter-frequency hard handover based on downlink QoS for BE services.
5. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center:Modifying RNC Parameters in Batches) to
activate inter-frequency hard handover based on downlink QoS for AMR and AMR-WB services.
6. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center:Modifying RNC Parameters in Batches) to
activate inter-frequency hard handover based on downlink QoS for VP services.
16.9.7 Deactivation
1. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
deactivate inter-frequency hard handover based on downlink QoS for BE services.
2. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
deactivate inter-frequency hard handover based on downlink QoS for AMR and AMR-WB services.
3. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
deactivate inter-frequency hard handover based on downlink QoS for VP services.
16.10.3 Requirements
Dependencies on Hardware
This feature does not depend on the hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
The license "Inter Frequency Hard Handover Based on UL QoS " on the RNC side has been
activated. For details about the license items and how to activate the license, seeLicense
Management Feature Parameter Description.
16.10.4 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to activate the inter-frequency hard handover.
2. Run the RNC MML command ADD UINTERFREQNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > Inter-frequency Neighboring Cell; CME batch
modification center: not supported) to add an inter-frequency neighboring cell.
3. Run the RNC MML command ADD UCELLINTERFREQHOCOV (CME single configuration:
UMTS Cell Configuration Express > Cell Parameters > Cell Oriented Coverage Based Inter-
frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERFREQHOCOV (CME single configuration: UMTS Radio Global Configuration Express >
HandOver Parameter Configuration > RNC Oriented Coverage Based Inter-frequency Handover
Measurement Algorithm Parameters; CME batch modification center: Modifying RNC Parameters
in Batches) (RNC level) to configure parameters related to UL-QoS-based inter-frequency hard
handover.
4. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
activate inter-frequency hard handover based on uplink QoS for BE services.
5. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center:Modifying RNC Parameters in Batches) to
activate inter-frequency hard handover based on uplink QoS for AMR and AMR-WB services.
6. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center:Modifying RNC Parameters in Batches) to
activate inter-frequency hard handover based on uplink QoS for VP services.
3. Ensure that the UE sends an RRC_MEAS_RPRT message to the RNC and the message
contains the event 6A parameter, as shown in Figure 16-6.
Figure 16-6 RRC_RB_RECFG message
4. Ensure that the RNC sends an RRC_MEAS_CTRL message to the NodeB to start event-
triggered or periodic inter-frequency measurement.
16.10.7 Deactivation
1. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
deactivate inter-frequency hard handover based on uplink QoS for BE services.
2. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
deactivate inter-frequency hard handover based on uplink QoS for AMR and AMR-WB services.
3. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
deactivate inter-frequency hard handover based on uplink QoS for VP services.
16.11.1 Requirements
Dependencies on Hardware
This feature does not depend on the hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
The license "Coverage Based Inter-RAT Handover Between UMTS and GSM/GPRS" on the RNC
side has been activated. For details about the license items and how to activate the license,
see License Management Feature Parameter Description.
Other Requirements
The UE supports relevant measurements and the handover procedure.
To enable videophone services to fall back to voice services, the MSC and UE must comply with
3GPP Release 6. For details, see section 4.3 Core Network procedure in 3GPP TS 23.172 V10.0.0.
16.11.2 Activation
NOTE:
This feature can be batch activated using the CME. For detailed operations, see the following section in
the CME product documentation or online help: Managing the CME > CME Guidelines > Enhanced
Feature Management > Feature Operation and Maintenance.
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches). In this step,
selectHO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH from
the HandOver Switch list.
2. Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification center:
not supported) to add an inter-frequency neighboring GSM cell.
3. Run the RNC MML command ADD UCELLINTERRATHOCOV (CME single configuration: UMTS
Cell Configuration Express > Cell Parameters > Cell Oriented Coverage Based Inter-rat Handover
Measurement Algorithm Parameters; CME batch modification center: Modifying UMTS Cell
Parameters in Batches) (cell level) or SET UINTERRATHOCOV (CME single configuration: UMTS
Radio Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
Coverage based Inter-rat Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) (RNC level) to configure parameters related to
coverage-based inter-RAT handover to GSM.
4. Run the RNC MML command MOD UTYPRABBASIC (CME single configuration: UMTS Radio
Global Configuration Express > Typical Service Configuration > Basic Information for
Typical Traffic Radio Access Bearer; CME batch modification center: not supported). In this step,
set Service Handover Indicator toHO_TO_GSM_SHOULD_NOT_BE_PERFORM.
16.11.3 MML Command Examples
//Activating Inter-RAT Handover Based on Coverage
SET UCORRMALGOSWITCH: HoSwitch=HO_INTER_RAT_CS_OUT_SWITCH-
1&HO_INTER_RAT_PS_OUT_SWITCH-1;
4. Click to display Uu Interface Trace on the RNC LMT. Under Uu Message Type,
select RRC_MEAS_CTRL.
5. Check in the traced messages whether the RNC has sent the UE an inter-RAT measurement
control message shown in Figure 16-8.
Figure 16-8 Inter-RAT measurement control message
NOTE:
To verify the measurement-based inter-RAT handover triggered by uplink QoS of UEs, you need
to Run the RNC MML command SET UQOSACT to turn on the QoS switches of different service
types and attenuate the signals of the current cell. Check whether UEs send the uplink QoS
measurement reports to the RNC. The verification steps are the same as those for event 2D.
The inter-RAT blind handover triggered by event 1F is a special application. You need to measure
the pilot strength and quality scope of the best cell where the blind handover is to be triggered.
Generally, the inter-RAT blind handover is not needed and therefore does not need to be verified.
To check whether a videophone service has fallen back to a voice service after being handed over to the
GSM network, perform the following steps:
1. Start Iu Interface Trace and Uu Interface Trace on the RNC LMT.
2. After video phone services are established, check in the Uu Interface Trace dialog box that the
UE sends to the RNC an RRC_MEAS_RPRT message, which contains the 3A report.
3. In the Iu Interface Trace dialog box, check that the RNC sends
an RAB_MODIFY_REQ message to the CN. In the RAB_MODIFY_REQ message, the value of
the IE alternativeRABConfigurationRequest is alternative-RAB-configuration-Requested.
16.11.5 Deactivation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to deactivate this feature.
2. Run the RNC MML command RMV UCELLINTERRATHOCOV (CME single configuration: UMTS
Cell Configuration Express > Cell Parameters > Cell Oriented Coverage Based Inter-rat Handover
Measurement Algorithm Parameters; CME batch modification center: not supported) (cell level)
or SET UINTERRATHOCOV (CME single configuration: UMTS Radio Global Configuration
Express > HandOver Parameter Configuration > RNC Oriented Coverage based Inter-rat Handover
Measurement Algorithm Parameters; CME batch modification center: Modifying RNC Parameters
in Batches) (RNC level) to remove or restore the parameters related to coverage-based inter-RAT
handover to GSM.
16.12.1 Requirements
Dependencies on Hardware
This feature does not depend on the hardware.
Dependencies on Other Features
The feature WRFD-020302 Inter Frequency Hard Handover Based on Coverage must be configured
before this feature is activated.
License
The license "Inter-RAT Handover Based on DL QoS" on the RNC side has been activated. For
details about the license items and how to activate the license, see License Management Feature
Parameter Description.
Other Requirements
The UE supports relevant measurements and the handover procedure.
16.12.2 Activation
1. (Optional) Run the RNC MML command SET UCORRMALGOSWITCH (CME single
configuration: UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification
center: Modifying RNC Parameters in Batches). In this step,
selectHO_INTER_RAT_PS_OUT_SWITCH under the HandOver Switch parameter.
NOTE:
Before activating this feature, perform 1 if HO_INTER_RAT_PS_OUT_SWITCH are not turned
on. You can run the RNC MML command LST UCORRMALGOSWITCH to check whether this
switch have been turned on.
2. Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification center:
not supported) to add an inter-RAT neighboring cell.
3. Run the RNC MML command SET UQOSHO (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC Oriented QoS Handover
Measurement Algorithm Parameters; CME batch modification center: Modifying RNC Parameters
in Batches) to set RNC-level parameters related to Inter-RAT Handover Based on DL QoS.
4. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
turn on QoS switches for different traffic classes.
16.12.5 Deactivation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches). In this step,
deselectHO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH under
the HandOver Switch parameter.
NOTE:
Do not
perform 1 if HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH have
been turned on before activating this feature.
2. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
turn off QoS switches for different traffic classes.
16.13.1 Requirements
Dependencies on Hardware
This feature does not depend on the hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
The license "Inter-RAT Handover Based on UL QoS" on the RNC side has been activated. For
details about the license items and how to activate the license, see License Management Feature
Parameter Description.
Other Requirements
The UE supports relevant measurements and the handover procedure.
16.13.2 Activation
1. (Optional) Run the RNC MML command SET UCORRMALGOSWITCH (CME single
configuration: UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification
center: Modifying RNC Parameters in Batches). In this step,
selectHO_INTER_RAT_PS_OUT_SWITCH under the HandOver Switch parameter.
NOTE:
Before activating this feature, perform 1 if HO_INTER_RAT_PS_OUT_SWITCH are not turned
on. You can run the RNC MML command LST UCORRMALGOSWITCH to check whether this
switch have been turned on.
2. Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification center:
not supported) to add an inter-RAT neighboring cell.
3. Run the RNC MML command SET UQOSHO (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC Oriented QoS Handover
Measurement Algorithm Parameters; CME batch modification center: Modifying RNC Parameters
in Batches) to set RNC-level parameters related to Inter-RAT Handover Based on UL QoS.
4. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
turn on QoS switches for different traffic classes.
3. Ensure that the NodeB reports to the RNC an NBAP_DEDI_MEAS_RPRT message, which
carries the event E parameter, as shown in Figure 16-10.
Figure 16-10 RRC_RB_RECFG message
4. Ensure that the RNC sends to the UE an RRC_MEAS_CTRL message and starts inter-frequency
measurement of the event or period type. Then, check that the corresponding traced message
indicates that the RNC has sent the inter-frequency measurement control message to the UE, as
shown in Figure 16-11.
Figure 16-11 RRC_RB_RECFG message
16.13.5 Deactivation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches). In this step,
deselectHO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH under
the HandOver Switch parameter.
NOTE:
Do not
perform 1 if HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH have
been turned on before activating this feature.
2. Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio Global
Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS Enhancement
Algorithm Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to
turn off QoS switches for different traffic classes.
16.14.1 Requirements
Dependencies on Hardware
The RNC should support the NACC RIM procedure and PS handovers. When RIM messages are
exchanged through the eCoordinator, the RNC should support the RIM procedure that is
implemented through Huawei proprietary eCoordinator.
Dependencies on Other Features
This feature is required only when one or several of the following inter-RAT handover features are
introduced:
WRFD-020303 Inter-RAT Handover Based on Coverage
WRFD-020305 Inter-RAT Handover Based on Service
WRFD-020306 Inter-RAT Handover Based on Load
WRFD-021200 HCS (Hierarchical Cell Structure)
License
This feature is not under license control.
Other Requirements
The UE must support the NACC procedure and PS handover.
The BSC must support the NACC RIM (RAN Information Management) procedure and
PS handover. When RIM messages are exchanged through the eCoordinator, the RNC must
support the RIM procedure that is implemented through Huawei proprietary eCoordinator.
The SGSN must support the NACC procedure and PS handover.When RIM messages
are exchanged through the CN, the SGSN must support the NACC procedure.
16.14.2 Deployment
For details about how to activate, verify, and deactivate this feature, see the following sections:
16.15 WRFD-02030801 NACC(Network Assisted Cell Change)
16.15.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
The configurations of the features on which this feature depends are complete. This feature
depends on the feature WRFD-020308 PS Inter-RAT Handover Phase 2.
License
The license "NACC(Network Assisted Cell Change)" on the RNC side has been activated. For
details about the license items and how to activate the license, see License Management Feature
Parameter Description.
Other Requirements
The UE must support the NACC procedure and comply with 3GPP Release 5 or later.
The BSC must support the NACC RIM (RAN Information Management) procedure.
When RIM messages are exchanged through the CN, the SGSN must comply with 3GPP
Release 5 or later and support the NACC procedure.
When RIM messages are exchanged through the eCoordinator, the BSC, RNC, and
Huawei proprietary eCoordinator must support the RIM procedure that is implemented through
the eCoordinator.
16.15.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to open the following switches in theHandOver switch parameter:
HO_INTER_RAT_PS_OUT_SWITCH
HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH
HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH
NOTE:
When the HO_INTER_RAT_PS_OUT_SWITCH is turned on,
the HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH does not take effect.
2. Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches)(for new neighboring cell) or MOD UEXT2GCELL(CME single configuration: Object Group
> UMTS Service Configuration and Maintenance Management > External Cell Configuration >
RNC 2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) (for the existing neighboring cell) to set Inter-RAT cell support RIM indicator to TRUE.
3. (Optional) If RIM messages are exchanged through Huawei proprietary eCoordinator, run the
RNC MML command SET URRCTRLSWITCH, and select theRIM_ON_ECO_SWITCH check box
under the PROCESSSWITCH5 parameter.
message.
5. Trace messages over the Uu interface to check whether there is an
RRC_CELL_CHANGE_ORDER_FROM_UTRAN message that carries system information on the
GSM side.
To enable RIM messages to be exchanged through Huawei proprietary eCoordinator, do as follows:
1. Run the RNC MML command LST UCORRMALGOSWITCH and check the settings of the PS
inter-RAT handover, NACC, and Relocation switches.
2. Run the RNC MML command LST UEXT2GCELL and check whether the inter-RAT neighboring
cell supports the RIM procedure.
3. Run the RNC MML command LST URRCTRLSWITCH and check whether the BSC supports the
RIM procedure that is implemented through the eCoordinator.
4. Check the signaling messages over the Sg interface before the UMTS-to-GSM handover is
performed. If an RNC DIRECT INFORMATION TRANSFER message has been sent to the
eCoordinator and an ECO DIRECT INFORMATION TRANSFER message sent by the
eCoordinator has been received over the Sg interface, the WRFD-02030801 NACC(Network
Assisted Cell Change) feature takes effect.
NOTE:
To implement this feature, the UE should support NACC. Therefore, the NACC-supportive UEs are
required for activation.
16.15.5 Deactivation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to setHO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH in
the HandOver switch parameter to 0.
2. Run the RNC MML command MOD UEXT2GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) to set Inter-RAT cell support RIM indicator toFALSE.
3. If RIM messages are exchanged through Huawei proprietary eCoordinator, run the RNC MML
command SET URRCTRLSWITCH, and deselect the RIM_ON_ECO_SWITCHcheck box under
the PROCESSSWITCH5 parameter.
16.16.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
The configurations of the features on which this feature depends are complete. This feature
depends on the feature WRFD-020308 PS Inter-RAT Handover Phase 2.
License
The license "PS Handover Between UMTS and GPRS" on the RNC side has been activated. For
details about the license items and how to activate the license, see License Management Feature
Parameter Description.
Other Requirements
The UE, GSM BSC, and SGSN must support the PS handover.
If RIM messages are exchanged through Huawei proprietary eCoordinator, the BSC and RNC must
connect to the same eCoordinator and be able to exchange RIM messages with the eCoordinator.
16.16.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to open the following switches in theHandOver switch parameter:
HO_INTER_RAT_PS_OUT_SWITCH
HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH
2. Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) to add a neighboring GSM cell to the UMTS coverage and to set the Inter-RAT cell
support PS HO indicator parameter to TRUE.
3. Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification center:
not supported) to add a neighboring GSM cell for the UMTS cell.
4. (Optional) Run the RNC MML command SET UINTERRATHOCOV (CME single configuration:
UMTS Radio Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
Coverage based Inter-rat Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set inter-RAT handover measurement related
parameters.
16.16.5 Deactivation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to setHO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH in
the HandOver switch parameter to 0.
2. Run the RNC MML command MOD UEXT2GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) to set the SuppPSHOFlag parameter toFALSE.
16.17.1 Requirements
Dependencies on Hardware
This feature does not depend on the hardware.
Dependencies on Other Features
This feature does not depend on other features.
License
The license "Inter system Service Handover" on the RNC side has been activated. For details about
the license items and how to activate the license, see License Management Feature Parameter
Description.
Other Requirements
To enable videophone services to fall back to voice services, the MSC and UE must comply with
3GPP Release 6. For details, see section 4.3 Core Network procedure in 3GPP TS 23.172 V10.0.0.
16.17.2 Activation
NOTE:
This feature can be batch activated using the CME. For detailed operations, see the following section in
the CME product documentation or online help: Managing the CME > CME Guidelines > Enhanced
Feature Management > Feature Operation and Maintenance.
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches). In this step,
selectHO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH from
the HandOver Switch list.
2. Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) to add a neighboring GSM cell.
3. Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification center:
not supported) to set neighbor relationships with the neighboring GSM cell.
4. Run the RNC MML command ADD UCELLHOCOMM (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell Oriented Handover Common Algorithm
Parameters; CME batch modification center: Modifying UMTS Cell Parameters in Batches). In this
step, set Inter-RAT CS handover switch or Inter-RAT PS handover switch to ON.
5. Run the RNC MML command ADD UCELLINTERRATHONCOV (CME single configuration:
UMTS Cell Configuration Express > Cell Parameters > Cell Oriented None-Coverage Based Inter-
rat Handover Measurement Algorithm Parameters; CME batch modification center: Modifying
UMTS Cell Parameters in Batches) (cell level) or SET UINTERRATHONCOV (CME single
configuration: UMTS Radio Global Configuration Express > HandOver Parameter Configuration >
RNC Oriented None-Coverage based Inter-rat Handover Measurement Algorithm Parameters;
CME batch modification center: Modifying RNC Parameters in Batches) (RNC level) to configure
parameters related to non-coverage-based inter-frequency handover to GSM.
To check whether a videophone service has fallen back to a voice service after being handed over to the
GSM network, perform the following steps:
1. Start Iu Interface Trace and Uu Interface Trace on the RNC LMT.
2. After video phone services are established, check in the Uu Interface Trace dialog box that the
UE sends to the RNC an RRC_MEAS_RPRT message, which contains the 3A report.
3. In the Iu Interface Trace dialog box, check that the RNC sends
an RAB_MODIFY_REQ message to the CN. In the RAB_MODIFY_REQ message, the value of
the IE alternativeRABConfigurationRequest is alternative-RAB-configuration-Requested.
16.17.5 Deactivation
Run the RNC MML command MOD UCELLHOCOMM (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell Oriented Handover Common Algorithm Parameters; CME
batch modification center: Modifying UMTS Cell Parameters in Batches). In this step, set Inter-RAT CS
handover switch or Inter-RAT PS handover switch to OFF.
16.18.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
If this feature is used for HSDPA or HSUPA load control, the feature WRFD-010610 HSDPA
Introduction Package or WRFD-010612 HSUPA Introduction Package has been configured
correspondingly before this feature is activated.
License
The license "Inter system Load Handover" on the RNC side has been activated. For details about
the license items and how to activate the license, see License Management Feature Parameter
Description.
Other Requirements
To enable videophone services to fall back to voice services, the MSC and UE must comply with
3GPP Release 6. For details, see section 4.3 Core Network procedure in 3GPP TS 23.172 V10.0.0.
16.18.2 Activation
NOTE:
This feature can be batch activated using the CME. For detailed operations, see the following section in
the CME product documentation or online help: Managing the CME > CME Guidelines > Enhanced
Feature Management > Feature Operation and Maintenance.
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to activate the inter-RAT handover. In this step, select
the HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH check boxes
under the parameter HandOver Switch.
2. Run the RNC MML command SET UCORRMALGOSWITCH. In this step, select
the HO_INTER_RAT_RNC_SERVICE_HO_SWITCH check box under the HandOver
Switch parameter.
3. Run the RNC MML command MOD UTYPRABBASIC. In this step, set Service Handover
Indicator to HO_TO_GSM_SHOULD_BE_PERFORM.
NOTE:
Setting Service Handover Indicator to HO_TO_GSM_SHOULD_BE_PERFORM facilitates feature
verification during lab tests. On a live network, set this parameter according to the network plan.
Ensure that the parameter setting is consistent with the LDR action-related parameter setting
mentioned in 11.
4. Enable the uplink air-interface LDR algorithm by selecting the UL_UU_LDR check box under
the Switch for Cell Load Control parameter in the RNC MML command ADD
UCELLALGOSWITCH.
5. Enable the downlink air-interface LDR algorithm by selecting the DL_UU_LDR check box under
the Switch for Cell Load Control parameter in the RNC MML commandADD
UCELLALGOSWITCH.
6. Enable the cell credit LDR algorithm by selecting the CELL_CREDIT_LDR check box under
the Switch for Cell Load Control parameter in the RNC MMLcommand ADD
UCELLALGOSWITCH.
7. Enable the credit load control algorithm at the NodeB or cell group level by selecting
the NODEB_CREDIT_LDR_SWITCH or LCG_CREDIT_LDR_SWITCH check box under the load
control algorithm switch parameter in the RNC MML command SET ULDCALGOPARA.
8. Enable the credit load congestion control algorithm at the NodeB or cell group level by selecting
the NODEB_CREDIT_LDR or LCG_CREDIT_LDR check box under the NodeB LDC algorithm
switch parameter in the RNC MML command ADD UNODEBALGOPARA.
NOTE:
Performing 4 to 8 facilitates feature verification during lab tests. On a live network, set the
parameters according to the network plan.
9. Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) to add the information about a GSM cell.
10. Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification center:
not supported) to add the GSM cell as a neighboring cell of the UMTS cell.
11. Run the RNC MML command ADD UCELLLDR (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell LDR Algorithm Parameters; CME batch
modification center: Modifying UMTS Cell Parameters in Batches) to set the inter-RAT handover
policy for the UMTS cell. In this step, set DL LDR fourth action toCSInterRatShouldBeLDHO(CS
domain inter-rat should be load handover), DL LDR fifth
action to PSInterRatShouldBeLDHO(PS domain inter-rat should be load handover), UL LDR
fourth action to CSInterRatShouldBeLDHO(CS domain inter-rat should be load handover),
and UL LDR fifth action toPSInterRatShouldBeLDHO(PS domain inter-rat should be load
handover).
NOTE:
Setting UL/DL LDR first action to CSInterRatShouldBeLDHO(CS domain inter-rat should be
load handover) and UL/DL LDR second action toPSInterRatShouldBeLDHO(PS domain inter-
rat should be load handover) facilitates feature verification during lab tests. On a live network, set
these parameters according to the network plan.
12. Run the RNC MML command MOD UCELLLDM. In this step, set the following parameters to
appropriate values: UL LDR trigger threshold, UL LDR release threshold, DL LDR trigger threshold,
DL LDR release threshold, and DL State Trans Hysteresis threshold.
13. Run the RNC MML command MOD UNODEBLDR. In this step, set UL LDR Credit SF reserved
threshold to an appropriate value for the credit LDR algorithm at the NodeB or cell group level.
14. Run the RNC MML command SET ULDCPERIOD. In this step, set LDR period timer length to
an appropriate value.
15. Run the RNC MML command ADD UCELLINTERRATHONCOV (CME single configuration:
UMTS Cell Configuration Express > Cell Parameters > Cell Oriented None-Coverage Based Inter-
rat Handover Measurement Algorithm Parameters; CME batch modification center: Modifying
UMTS Cell Parameters in Batches) (at the cell level) orSET UINTERRATHONCOV (CME single
configuration: UMTS Radio Global Configuration Express > HandOver Parameter Configuration >
RNC Oriented None-Coverage based Inter-rat Handover Measurement Algorithm Parameters;
CME batch modification center: Modifying RNC Parameters in Batches) (at the RNC level) to
configure parameters related to non-coverage-based inter-frequency handover to GSM.
16.19.1 Requirements
Dependencies on Hardware
This feature does not have any special requirements for hardware.
Dependencies on Other Features
This feature is required only when one of the following features is available:
WRFD-020305 Inter-RAT Handover Based on Service
WRFD-020306 Inter-RAT Handover Based on Load
WRFD-021200 HCS (Hierarchical Cell Structure)
WRFD-020400 DRD Introduction Package
WRFD-020308 Inter-RAT Handover Phase 2
License
The license "3G/2G Common Load Management" on the RNC side has been activated. For details
about the license items and how to activate the license, see License Management Feature
Parameter Description.
Other Requirements
The CN and BSS must support this feature.
Before deploying this feature, ensure that the Handover Request Acknowledge messages sent from
GSM to UMTS carry load information of GSM cells, because the RNC needs to determine whether
to allow a UMTS-to-GSM handover based on load information of GSM cells.
16.19.2 Activation
1. Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration: UMTS
Radio Global Configuration Express > Connection_Oriented RRM Switch Configuration >
Connection Oriented Algorithm Switches; CME batch modification center: Modifying RNC
Parameters in Batches) to enable the inter-RAT handover. In this step,
select HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH through
the HandOver Switch.
2. Run the RNC MML command SET UINTERRATHONCOV (CME single configuration: UMTS
Radio Global Configuration Express > HandOver Parameter Configuration > RNC Oriented None-
Coverage based Inter-rat Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to enable the 3G/2G common load management
function. In this step, select the Send Load Info to GSM Ind and NCOV Reloc Ind Based on
GSM Cell Load.
3. Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object Group >
UMTS Service Configuration and Maintenance Management > External Cell Configuration > RNC
2G External Cell; CME batch modification center: Modifying RNC External Cell Parameters in
Batches) to add a GSM cell neighboring to the UMTS coverage.
4. Run the RNC MML command ADD U2GNCELL(CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch modification center:
not supported) to set a GSM cell as the UMTS cell's neighboring cell.
NOTE:
Consult Huawei engineers about the verification solution to obtain professional technical support.
16.19.5 Deactivation
Run the RNC MML command SET UINTERRATHONCOV (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented None-Coverage
based Inter-rat Handover Measurement Algorithm Parameters; CME batch modification center: Modifying
RNC Parameters in Batches) to set the parameter Send Load Info to GSM Ind to OFF and the
parameter NCOV Reloc Ind based on GSM cell load to OFF.
16.19.6 MML Command Examples
//Deactivating 3G/2G Common Load Management
SET UINTERRATHONCOV: SndLdInfo2GsmInd=OFF, NcovHoOn2GldInd=OFF;
16.20.1 Requirements
Dependencies on Hardware
None
Dependencies on Other Features
The configurations of the features that are required by this feature are complete. This feature
requires the WRFD-010610 HSDPA Introduction Package feature.
License
The licenses "HSDPA RRM package 1" and "HSDPA function" on the NodeB side have been
activated. For details about how to activate licenses, see License Management Feature Parameter
Description.
16.20.2 Activation
The methods of activating intra-frequency, inter-frequency, and inter-RAT handovers are the same for
HSDPA UEs and R99 UEs. For details, see the following sections:
16.4 WRFD-020301 Intra Frequency Hard Handover
16.20.4 Deactivation
This feature does not need to be deactivated.
17 Parameters
Table 17-1 Parameter description
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RsvS B SET No Non Meaning: RRM algorithm reserved U32 Switch Para 4. The 32-
witch4 S UAL ne e bit parameter is reserved for further change request use. Disuse
C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
0 parameter is not recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_4_BIT1,
RESERVED_SWITCH_4_BIT2,
RESERVED_SWITCH_4_BIT3,
RESERVED_SWITCH_4_BIT4,
RESERVED_SWITCH_4_BIT5,
RESERVED_SWITCH_4_BIT6,
RESERVED_SWITCH_4_BIT7,
RESERVED_SWITCH_4_BIT8,
RESERVED_SWITCH_4_BIT9,
RESERVED_SWITCH_4_BIT10,
RESERVED_SWITCH_4_BIT11,
RESERVED_SWITCH_4_BIT12,
RESERVED_SWITCH_4_BIT13,
RESERVED_SWITCH_4_BIT14,
RESERVED_SWITCH_4_BIT15,
RESERVED_SWITCH_4_BIT16,
RESERVED_SWITCH_4_BIT17,
RESERVED_SWITCH_4_BIT18,
RESERVED_SWITCH_4_BIT19,
RESERVED_SWITCH_4_BIT20,
RESERVED_SWITCH_4_BIT21,
RESERVED_SWITCH_4_BIT22,
RESERVED_SWITCH_4_BIT23,
RESERVED_SWITCH_4_BIT24,
RESERVED_SWITCH_4_BIT25,
RESERVED_SWITCH_4_BIT26,
RESERVED_SWITCH_4_BIT27,
RESERVED_SWITCH_4_BIT28,
RESERVED_SWITCH_4_BIT29,
RESERVED_SWITCH_4_BIT30,
RESERVED_SWITCH_4_BIT31,
RESERVED_SWITCH_4_BIT32
Unit: None
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_4_BIT12:0,RESERVED_SWITCH_4_B
IT13:0,RESERVED_SWITCH_4_BIT14:0,RESERVED_SWIT
CH_4_BIT15:0,RESERVED_SWITCH_4_BIT16:0,RESERVED
_SWITCH_4_BIT17:0,RESERVED_SWITCH_4_BIT18:0,RES
ERVED_SWITCH_4_BIT19:0,RESERVED_SWITCH_4_BIT2
0:0,RESERVED_SWITCH_4_BIT21:0,RESERVED_SWITCH_
4_BIT22:0,RESERVED_SWITCH_4_BIT23:0,RESERVED_S
WITCH_4_BIT24:0,RESERVED_SWITCH_4_BIT25:0,RESER
VED_SWITCH_4_BIT26:0,RESERVED_SWITCH_4_BIT27:0,
RESERVED_SWITCH_4_BIT28:0,RESERVED_SWITCH_4_B
IT29:0,RESERVED_SWITCH_4_BIT30:0,RESERVED_SWIT
CH_4_BIT31:0,RESERVED_SWITCH_4_BIT32:0
RsvS B SET No Non Meaning: RRM algorithm reserved U32 Switch Para 4. The 32-
witch4 S UAL ne e bit parameter is reserved for further change request use. Disuse
C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
1 parameter is not recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_4_BIT1,
RESERVED_SWITCH_4_BIT2,
RESERVED_SWITCH_4_BIT3,
RESERVED_SWITCH_4_BIT4,
RESERVED_SWITCH_4_BIT5,
RESERVED_SWITCH_4_BIT6,
RESERVED_SWITCH_4_BIT7,
RESERVED_SWITCH_4_BIT8,
RESERVED_SWITCH_4_BIT9,
RESERVED_SWITCH_4_BIT10,
RESERVED_SWITCH_4_BIT11,
RESERVED_SWITCH_4_BIT12,
RESERVED_SWITCH_4_BIT13,
RESERVED_SWITCH_4_BIT14,
RESERVED_SWITCH_4_BIT15,
RESERVED_SWITCH_4_BIT16,
RESERVED_SWITCH_4_BIT17,
RESERVED_SWITCH_4_BIT18,
RESERVED_SWITCH_4_BIT19,
RESERVED_SWITCH_4_BIT20,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_4_BIT21,
RESERVED_SWITCH_4_BIT22,
RESERVED_SWITCH_4_BIT23,
RESERVED_SWITCH_4_BIT24,
RESERVED_SWITCH_4_BIT25,
RESERVED_SWITCH_4_BIT26,
RESERVED_SWITCH_4_BIT27,
RESERVED_SWITCH_4_BIT28,
RESERVED_SWITCH_4_BIT29,
RESERVED_SWITCH_4_BIT30,
RESERVED_SWITCH_4_BIT31,
RESERVED_SWITCH_4_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_4_BIT1,
RESERVED_SWITCH_4_BIT2,
RESERVED_SWITCH_4_BIT3,
RESERVED_SWITCH_4_BIT4,
RESERVED_SWITCH_4_BIT5,
RESERVED_SWITCH_4_BIT6,
RESERVED_SWITCH_4_BIT7,
RESERVED_SWITCH_4_BIT8,
RESERVED_SWITCH_4_BIT9,
RESERVED_SWITCH_4_BIT10,
RESERVED_SWITCH_4_BIT11,
RESERVED_SWITCH_4_BIT12,
RESERVED_SWITCH_4_BIT13,
RESERVED_SWITCH_4_BIT14,
RESERVED_SWITCH_4_BIT15,
RESERVED_SWITCH_4_BIT16,
RESERVED_SWITCH_4_BIT17,
RESERVED_SWITCH_4_BIT18,
RESERVED_SWITCH_4_BIT19,
RESERVED_SWITCH_4_BIT20,
RESERVED_SWITCH_4_BIT21,
RESERVED_SWITCH_4_BIT22,
RESERVED_SWITCH_4_BIT23,
RESERVED_SWITCH_4_BIT24,
RESERVED_SWITCH_4_BIT25,
RESERVED_SWITCH_4_BIT26,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_4_BIT27,
RESERVED_SWITCH_4_BIT28,
RESERVED_SWITCH_4_BIT29,
RESERVED_SWITCH_4_BIT30,
RESERVED_SWITCH_4_BIT31,
RESERVED_SWITCH_4_BIT32
Default Value:
RESERVED_SWITCH_4_BIT1:0,RESERVED_SWITCH_4_BI
T2:0,RESERVED_SWITCH_4_BIT3:0,RESERVED_SWITCH_
4_BIT4:0,RESERVED_SWITCH_4_BIT5:0,RESERVED_SWI
TCH_4_BIT6:0,RESERVED_SWITCH_4_BIT7:0,RESERVED
_SWITCH_4_BIT8:0,RESERVED_SWITCH_4_BIT9:0,RESER
VED_SWITCH_4_BIT10:0,RESERVED_SWITCH_4_BIT11:0,
RESERVED_SWITCH_4_BIT12:0,RESERVED_SWITCH_4_B
IT13:0,RESERVED_SWITCH_4_BIT14:0,RESERVED_SWIT
CH_4_BIT15:0,RESERVED_SWITCH_4_BIT16:0,RESERVED
_SWITCH_4_BIT17:0,RESERVED_SWITCH_4_BIT18:0,RES
ERVED_SWITCH_4_BIT19:0,RESERVED_SWITCH_4_BIT2
0:0,RESERVED_SWITCH_4_BIT21:0,RESERVED_SWITCH_
4_BIT22:0,RESERVED_SWITCH_4_BIT23:0,RESERVED_S
WITCH_4_BIT24:0,RESERVED_SWITCH_4_BIT25:0,RESER
VED_SWITCH_4_BIT26:0,RESERVED_SWITCH_4_BIT27:0,
RESERVED_SWITCH_4_BIT28:0,RESERVED_SWITCH_4_B
IT29:0,RESERVED_SWITCH_4_BIT30:0,RESERVED_SWIT
CH_4_BIT31:0,RESERVED_SWITCH_4_BIT32:0
W HS that a cell does not support HSUPA due to high CPU load on the
RF UP DSP. This switch is turned off by default. OFF: This switch is
D- A turned off. When the NodeB reports that the cell does not
02 2ms support HSUPA services, the RNC does not trigger retry to the
02 TTI HSPA channel in the following scenarios:The current cell
03 Inte support the channel retry from the DCH to the E-DCH.The
W r current cell support channel retries from DCH to the E-DCH and
RF RN the HSDSCH. ON: This switch is turned on. When the NodeB
D- C reports that the cell does not support HSUPA services, the RNC
02 Soft does not trigger retry to the HSPA channel during the DCH to E-
03 Han DCH channel retry. 3.
03 dov PERFENH_MC_OPT_AFTER_RETRANS_CHG_SWITCH:
W er Policy used when the RNC receives a request for changing the
RF Inte target number of retransmissions during an E-DCH-to-DCH
D- r- (E2D) channel migration. ON: This switch is turned on. Upon
14 RA receiving the request for changing the target number of
02 T retransmissions, the RNC continues the channel migration
18 Han procedure and then updates measurement control. OFF: This
dov switch is turned off. Upon receiving the request for changing the
W
er target number of retransmissions, the RNC instantly updates
RF
Bas measurement control and then performs the channel migration.
D-
ed However, this increases the call drop rate. 4.
15
on PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH: Whether
02
Cov the RNC changes the radio bearer identity when CS services are
17
erag handed over from E-DCHs or HS-DSCHs to DCHs. This switch
W is turned off by default. When this switch is turned on, the RNC
RF e
changes the radio bearer identity. When this switch is turned off,
D- Ser
the RNC does not change the radio bearer identity. For details,
02 vice
see section 8.6.4.2 in 3GPP TS 25.331 V8.4.0. 5.
04 -
PERFENH_RRC_DRD_FAILED_RED_GSM_SWITCH:
00 Bas
Whether the RNC carries the information about the configured
W ed
neighboring GSM cells in the RRC CONNECTION REJECT
RF PS
message when neighboring GSM cells are configured during an
D- Han
RRC inter-RAT redirection based on admission failures. For UEs
02 dov
of 3GPP Release 6 or a later version, when this switch is turned
05 er
on, the RNC carries the information about the configured
03 fro
neighboring GSM cells in the RRC CONNECTION REJECT
m
W message. When this switch is turned off, the RNC does not carry
UM
RF the information about the configured neighboring GSM cells in
TS
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
LTE Whether the RNC re-attempts to apply for DCH resources when
Co the NodeB sends to the RNC cause value not-enough-user-plane-
mbi processing-resources during the request of E-DCH or HS-DSCH
nati resources for an intra-RAT handover. When this switch is turned
on on, the RNC re-attempts to apply for the DCH resources in the
of preceding scenario. When this switch is turned off, the RNC
One stops applying for any channel resources. 17.
CS PERFENH_LTE_NCELL_FILTE_OPT_SWITCH: Whether the
Ser RNC filters out neighboring LTE cells based on the principle of
vice preferentially selecting a maximum of four LTE FDD EARFCNs
and and four LTE TDD EARFCNs when the following conditions are
One met: 1. The active set contains more than one cell. 2. Each cell is
PS configured with multiple neighboring LTE cells. 3.
Ser HO_MC_NCELL_COMBINE_SWITCH of the "HoSwitch"
vice parameter in the "SET UCORRMALGOSWITCH" command
Dir and HO_MC_LTE_NCELL_COMBINE_SWITCH of the
ect "HoSwitch1" parameter in the "SET UCORRMALGOSWITCH"
Sig command are turned on. When this switch is turned on, the RNC
nali filters out the neighboring LTE cells based on the principle of
ng preferentially selecting a maximum of four LTE FDD EARFCNs
Con and four LTE TDD EARFCNs, preferentially selects the
nect neighboring LTE cells with the largest number of times the LTE
ion cells are configured as the neighboring cells for different cells in
Re- the active set until the number of the selected neighboring LTE
esta cells meets the specifications, and then filters out the excessive
blis neighboring LTE cells to obtain the candidate neighboring cell
hme list. When this switch is turned off, the RNC selects the
nt neighboring LTE cells with the largest number of times the LTE
(DS cells are configured as the neighboring cells for different cells in
CR) the active set until the number of the selected neighboring LTE
cells meets the specifications, filters out the excessive
Inte
neighboring LTE cells, and then selects the neighboring LTE
r-
cells on the selected EARFCNS according to the principle of
RA
preferentially selecting a maximum of four LTE FDD EARFCNs
T
and four LTE TDD EARFCNs. 18.
Han
PERFENH_U2L_PUNISH_BASED_ABS_FREQ_SWITCH:
dov
Whether a UE is allowed to perform a non-coverage-based
er
UMTS-to-LTE redirection after a redirection from UMTS to LTE
Bas
when
ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
on HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_SWITCH of
Loa the HoSwitch1 parameter in the SET UCORRMALGOSWITCH
d command is turned on. When this switch is turned on, the UE is
not allowed to be redirected back to LTE. When this switch is
turned off, the UE is allowed to be redirected back to LTE. 19.
PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SWITCH:
Value of the HE bit IE during the RB reconfiguration. The HE bit
IE indicates whether the AMD PDU contains the length indicator
(LI). For details about this parameter, see 3GPP TS 25.321.
When this switch is turned on. During the RB reconfiguration,
the value of the HE bit IE for other operators' RNCs is
unchanged. When this switch is turned off. During the RB
reconfiguration, the HE bit IE for other operators' RNCs is
forcibly changed to the value of the HE bit IE for Huawei RNC,
which results in call drops. 20.
PERFENH_HHO_RELOC_OUT_WITH_MR_SWITCH:
Whether compatibility processing is performed on the
RELOCATION REQUIRED message during a combined hard
handover and SRNS relocation. When this switch is turned on.
Compatibility processing is performed so that the
RELOCATION REQUIRED carries the RSCP and Ec/N0
measurement results of the target cell. When this switch is turned
off. Compatibility processing is not performed so that the
RELOCATION REQUIRED does not carry the RSCP and Ec/N0
measurement results of the target cell. 21.
PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITCH:
Whether to initiate service-based UMTS-to-LTE handovers or
redirections after a P2D procedure is triggered for CS users.
After this switch is turned on, service-based UMTS-to-LTE
handovers or redirections are allowed, causing the CS service
establishment to fail. After the switch is turned off, service-based
UMTS-to-LTE handovers or redirections are not allowed. 22.
PERFENH_RB_RECFG_TRIG_SERVICE_U2L_SWITCH:
Whether to initiate service-based UMTS-to-LTE handovers or
redirections after RBs are reconfigured for a PS user. After this
switch is turned on, service-based UMTS-to-LTE handovers or
redirections are allowed after RBs are reconfigured for a PS user.
In this case, the user is always in the compressed mode if
"ChannelRetryHoTimerLen" is set to a value other than 0 in the
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
_ALLOW_D2F_SWITCH:1,PERFENH_RAB_REL_WITH_PS
_D2F_OPT_SWITCH:1,PERFENH_DRNC_CU_WITHOUT_E
XTCELL_SWITCH:1,PERFENH_HO_NODEB_UP_RES_LIM
IT_E2D_SWITCH:1,PERFENH_LTE_NCELL_FILTE_OPT_S
WITCH:1,PERFENH_U2L_PUNISH_BASED_ABS_FREQ_S
WITCH:0,PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SW
ITCH:1,PERFENH_HHO_RELOC_OUT_WITH_MR_SWITC
H:0,PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITCH:0,P
ERFENH_RB_RECFG_TRIG_SERVICE_U2L_SWITCH:0,PE
RFENH_PERMIT_U2L_ONLY_UE_FROM_L_SWITCH:0,PE
RFENH_DTXDRX_ENABLEDELAY_CFGOPT_SWITCH:1,P
ERFENH_MCDRD_FAIL_PENALTY_OPT_SWITCH:1,PERF
ENH_HSDPA_SPI_WEIGHT_UPDATE_SWITCH:0
W er Policy used when the RNC receives a request for changing the
RF Inte target number of retransmissions during an E-DCH-to-DCH
D- r- (E2D) channel migration. ON: This switch is turned on. Upon
14 RA receiving the request for changing the target number of
02 T retransmissions, the RNC continues the channel migration
18 Han procedure and then updates measurement control. OFF: This
W dov switch is turned off. Upon receiving the request for changing the
RF er target number of retransmissions, the RNC instantly updates
D- Bas measurement control and then performs the channel migration.
15 ed However, this increases the call drop rate. 4.
02 on PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH: Whether
17 Cov the RNC changes the radio bearer identity when CS services are
W erag handed over from E-DCHs or HS-DSCHs to DCHs. This switch
RF e is turned off by default. When this switch is turned on, the RNC
D- Ser changes the radio bearer identity. When this switch is turned off,
02 vice the RNC does not change the radio bearer identity. For details,
04 - see section 8.6.4.2 in 3GPP TS 25.331 V8.4.0. 5.
00 Bas PERFENH_RRC_DRD_FAILED_RED_GSM_SWITCH:
ed Whether the RNC carries the information about the configured
W
PS neighboring GSM cells in the RRC CONNECTION REJECT
RF
Han message when neighboring GSM cells are configured during an
D-
dov RRC inter-RAT redirection based on admission failures. For UEs
02
er of 3GPP Release 6 or a later version, when this switch is turned
05
fro on, the RNC carries the information about the configured
03
m neighboring GSM cells in the RRC CONNECTION REJECT
W message. When this switch is turned off, the RNC does not carry
RF UM
TS the information about the configured neighboring GSM cells in
D- the RRC CONNECTION REJECT message. 6.
02 to
LTE PERFENH_IRAT_COV_HO_NCELL_PRE_SWITCH: Whether
06 high-priority neighboring cells or frequencies are preferred
05 Loa
during coverage-based inter-RAT handovers. When this switch is
W d
turned on, high-priority neighboring cells or frequencies are
RF Bas
preferred. If neighboring cells or frequencies have the same
D- ed
priority, those with better signal quality are preferred. If their
15 PS
signal quality is the same, the first selected neighboring cell or
02 Han
frequency is the target cell or frequency. For UMTS-to-GSM
20 dov
handovers, the neighboring cell with a smaller value of the
er
W "HOPrio" parameter in the "ADD U2GNCELL" command is
fro
RF preferentially selected as the target cell. For UMTS-to-LTE
m
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
PERFENH_RCS_PS_DL_ON_DCH_SWITCH,
PERFENH_HSUPA_CAP_CHG_HRETRY_LMT_SWITCH,
PERFENH_MC_OPT_AFTER_RETRANS_CHG_SWITCH,
PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH,
PERFENH_RRC_DRD_FAILED_RED_GSM_SWITCH,
PERFENH_IRAT_COV_HO_NCELL_PRE_SWITCH,
PERFENH_LTE_NCELL_SEL_OPT_SWITCH,
PERFENH_GSM_NCELL_SEL_OPT_SWITCH,
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWITCH,
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH,
PERFENH_MULTI_PS_DCCC_SWITCH,
PERFENH_CHL_CHG_FAIL_MC_OLPC_OPT_SWITCH,
PERFENH_SET2MBR_ALLOW_D2F_SWITCH,
PERFENH_RAB_REL_WITH_PS_D2F_OPT_SWITCH,
PERFENH_DRNC_CU_WITHOUT_EXTCELL_SWITCH,
PERFENH_HO_NODEB_UP_RES_LIMIT_E2D_SWITCH,
PERFENH_LTE_NCELL_FILTE_OPT_SWITCH,
PERFENH_U2L_PUNISH_BASED_ABS_FREQ_SWITCH,
PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SWITCH,
PERFENH_HHO_RELOC_OUT_WITH_MR_SWITCH,
PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITCH,
PERFENH_RB_RECFG_TRIG_SERVICE_U2L_SWITCH,
PERFENH_PERMIT_U2L_ONLY_UE_FROM_L_SWITCH,
PERFENH_DTXDRX_ENABLEDELAY_CFGOPT_SWITCH,
PERFENH_MCDRD_FAIL_PENALTY_OPT_SWITCH,
PERFENH_HSDPA_SPI_WEIGHT_UPDATE_SWITCH
Unit: None
Actual Value Range:
PERFENH_RCS_PS_DL_ON_DCH_SWITCH,
PERFENH_HSUPA_CAP_CHG_HRETRY_LMT_SWITCH,
PERFENH_MC_OPT_AFTER_RETRANS_CHG_SWITCH,
PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH,
PERFENH_RRC_DRD_FAILED_RED_GSM_SWITCH,
PERFENH_IRAT_COV_HO_NCELL_PRE_SWITCH,
PERFENH_LTE_NCELL_SEL_OPT_SWITCH,
PERFENH_GSM_NCELL_SEL_OPT_SWITCH,
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWITCH,
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH,
PERFENH_MULTI_PS_DCCC_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
PERFENH_CHL_CHG_FAIL_MC_OLPC_OPT_SWITCH,
PERFENH_SET2MBR_ALLOW_D2F_SWITCH,
PERFENH_RAB_REL_WITH_PS_D2F_OPT_SWITCH,
PERFENH_DRNC_CU_WITHOUT_EXTCELL_SWITCH,
PERFENH_HO_NODEB_UP_RES_LIMIT_E2D_SWITCH,
PERFENH_LTE_NCELL_FILTE_OPT_SWITCH,
PERFENH_U2L_PUNISH_BASED_ABS_FREQ_SWITCH,
PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SWITCH,
PERFENH_HHO_RELOC_OUT_WITH_MR_SWITCH,
PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITCH,
PERFENH_RB_RECFG_TRIG_SERVICE_U2L_SWITCH,
PERFENH_PERMIT_U2L_ONLY_UE_FROM_L_SWITCH,
PERFENH_DTXDRX_ENABLEDELAY_CFGOPT_SWITCH,
PERFENH_MCDRD_FAIL_PENALTY_OPT_SWITCH,
PERFENH_HSDPA_SPI_WEIGHT_UPDATE_SWITCH
Default Value:
PERFENH_RCS_PS_DL_ON_DCH_SWITCH:0,PERFENH_H
SUPA_CAP_CHG_HRETRY_LMT_SWITCH:0,PERFENH_M
C_OPT_AFTER_RETRANS_CHG_SWITCH:1,PERFENH_CS
OVERH_H2D_RBID_CHG_SWITCH:0,PERFENH_RRC_DR
D_FAILED_RED_GSM_SWITCH:1,PERFENH_IRAT_COV_
HO_NCELL_PRE_SWITCH:0,PERFENH_LTE_NCELL_SEL_
OPT_SWITCH:0,PERFENH_GSM_NCELL_SEL_OPT_SWIT
CH:0,PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWITC
H:0,PERFENH_ICMP_ACCELERATOR_OPT_SWITCH:0,PE
RFENH_MULTI_PS_DCCC_SWITCH:0,PERFENH_CHL_CH
G_FAIL_MC_OLPC_OPT_SWITCH:1,PERFENH_SET2MBR
_ALLOW_D2F_SWITCH:1,PERFENH_RAB_REL_WITH_PS
_D2F_OPT_SWITCH:1,PERFENH_DRNC_CU_WITHOUT_E
XTCELL_SWITCH:1,PERFENH_HO_NODEB_UP_RES_LIM
IT_E2D_SWITCH:1,PERFENH_LTE_NCELL_FILTE_OPT_S
WITCH:1,PERFENH_U2L_PUNISH_BASED_ABS_FREQ_S
WITCH:0,PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SW
ITCH:1,PERFENH_HHO_RELOC_OUT_WITH_MR_SWITC
H:0,PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITCH:0,P
ERFENH_RB_RECFG_TRIG_SERVICE_U2L_SWITCH:0,PE
RFENH_PERMIT_U2L_ONLY_UE_FROM_L_SWITCH:0,PE
RFENH_DTXDRX_ENABLEDELAY_CFGOPT_SWITCH:1,P
ERFENH_MCDRD_FAIL_PENALTY_OPT_SWITCH:1,PERF
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ENH_HSDPA_SPI_WEIGHT_UPDATE_SWITCH:0
RsvS B SET No Non Meaning: RRM algorithm reserved U32 Switch Para 1. The 32-
witch1 S UAL ne e bit parameter is reserved for further change request use. Disuse
C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
0 parameter is not recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_1_BIT1,
RESERVED_SWITCH_1_BIT2,
RESERVED_SWITCH_1_BIT3,
RESERVED_SWITCH_1_BIT4,
RESERVED_SWITCH_1_BIT5,
RESERVED_SWITCH_1_BIT6,
RESERVED_SWITCH_1_BIT7,
RESERVED_SWITCH_1_BIT8,
RESERVED_SWITCH_1_BIT9,
RESERVED_SWITCH_1_BIT10,
RESERVED_SWITCH_1_BIT11,
RESERVED_SWITCH_1_BIT12,
RESERVED_SWITCH_1_BIT13,
RESERVED_SWITCH_1_BIT14,
RESERVED_SWITCH_1_BIT15,
RESERVED_SWITCH_1_BIT16,
RESERVED_SWITCH_1_BIT17,
RESERVED_SWITCH_1_BIT18,
RESERVED_SWITCH_1_BIT19,
RESERVED_SWITCH_1_BIT20,
RESERVED_SWITCH_1_BIT21,
RESERVED_SWITCH_1_BIT22,
RESERVED_SWITCH_1_BIT23,
RESERVED_SWITCH_1_BIT24,
RESERVED_SWITCH_1_BIT25,
RESERVED_SWITCH_1_BIT26,
RESERVED_SWITCH_1_BIT27,
RESERVED_SWITCH_1_BIT28,
RESERVED_SWITCH_1_BIT29,
RESERVED_SWITCH_1_BIT30,
RESERVED_SWITCH_1_BIT31,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_1_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_1_BIT1,
RESERVED_SWITCH_1_BIT2,
RESERVED_SWITCH_1_BIT3,
RESERVED_SWITCH_1_BIT4,
RESERVED_SWITCH_1_BIT5,
RESERVED_SWITCH_1_BIT6,
RESERVED_SWITCH_1_BIT7,
RESERVED_SWITCH_1_BIT8,
RESERVED_SWITCH_1_BIT9,
RESERVED_SWITCH_1_BIT10,
RESERVED_SWITCH_1_BIT11,
RESERVED_SWITCH_1_BIT12,
RESERVED_SWITCH_1_BIT13,
RESERVED_SWITCH_1_BIT14,
RESERVED_SWITCH_1_BIT15,
RESERVED_SWITCH_1_BIT16,
RESERVED_SWITCH_1_BIT17,
RESERVED_SWITCH_1_BIT18,
RESERVED_SWITCH_1_BIT19,
RESERVED_SWITCH_1_BIT20,
RESERVED_SWITCH_1_BIT21,
RESERVED_SWITCH_1_BIT22,
RESERVED_SWITCH_1_BIT23,
RESERVED_SWITCH_1_BIT24,
RESERVED_SWITCH_1_BIT25,
RESERVED_SWITCH_1_BIT26,
RESERVED_SWITCH_1_BIT27,
RESERVED_SWITCH_1_BIT28,
RESERVED_SWITCH_1_BIT29,
RESERVED_SWITCH_1_BIT30,
RESERVED_SWITCH_1_BIT31,
RESERVED_SWITCH_1_BIT32
Default Value:
RESERVED_SWITCH_1_BIT1:0,RESERVED_SWITCH_1_BI
T2:0,RESERVED_SWITCH_1_BIT3:0,RESERVED_SWITCH_
1_BIT4:0,RESERVED_SWITCH_1_BIT5:0,RESERVED_SWI
TCH_1_BIT6:0,RESERVED_SWITCH_1_BIT7:0,RESERVED
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
_SWITCH_1_BIT8:0,RESERVED_SWITCH_1_BIT9:0,RESER
VED_SWITCH_1_BIT10:0,RESERVED_SWITCH_1_BIT11:0,
RESERVED_SWITCH_1_BIT12:0,RESERVED_SWITCH_1_B
IT13:0,RESERVED_SWITCH_1_BIT14:0,RESERVED_SWIT
CH_1_BIT15:0,RESERVED_SWITCH_1_BIT16:0,RESERVED
_SWITCH_1_BIT17:0,RESERVED_SWITCH_1_BIT18:0,RES
ERVED_SWITCH_1_BIT19:0,RESERVED_SWITCH_1_BIT2
0:0,RESERVED_SWITCH_1_BIT21:0,RESERVED_SWITCH_
1_BIT22:0,RESERVED_SWITCH_1_BIT23:0,RESERVED_S
WITCH_1_BIT24:0,RESERVED_SWITCH_1_BIT25:0,RESER
VED_SWITCH_1_BIT26:0,RESERVED_SWITCH_1_BIT27:0,
RESERVED_SWITCH_1_BIT28:0,RESERVED_SWITCH_1_B
IT29:0,RESERVED_SWITCH_1_BIT30:0,RESERVED_SWIT
CH_1_BIT31:0,RESERVED_SWITCH_1_BIT32:0
RsvS B SET No Non Meaning: RRM algorithm reserved U32 Switch Para 1. The 32-
witch1 S UAL ne e bit parameter is reserved for further change request use. Disuse
C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
1 parameter is not recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_1_BIT1,
RESERVED_SWITCH_1_BIT2,
RESERVED_SWITCH_1_BIT3,
RESERVED_SWITCH_1_BIT4,
RESERVED_SWITCH_1_BIT5,
RESERVED_SWITCH_1_BIT6,
RESERVED_SWITCH_1_BIT7,
RESERVED_SWITCH_1_BIT8,
RESERVED_SWITCH_1_BIT9,
RESERVED_SWITCH_1_BIT10,
RESERVED_SWITCH_1_BIT11,
RESERVED_SWITCH_1_BIT12,
RESERVED_SWITCH_1_BIT13,
RESERVED_SWITCH_1_BIT14,
RESERVED_SWITCH_1_BIT15,
RESERVED_SWITCH_1_BIT16,
RESERVED_SWITCH_1_BIT17,
RESERVED_SWITCH_1_BIT18,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_1_BIT19,
RESERVED_SWITCH_1_BIT20,
RESERVED_SWITCH_1_BIT21,
RESERVED_SWITCH_1_BIT22,
RESERVED_SWITCH_1_BIT23,
RESERVED_SWITCH_1_BIT24,
RESERVED_SWITCH_1_BIT25,
RESERVED_SWITCH_1_BIT26,
RESERVED_SWITCH_1_BIT27,
RESERVED_SWITCH_1_BIT28,
RESERVED_SWITCH_1_BIT29,
RESERVED_SWITCH_1_BIT30,
RESERVED_SWITCH_1_BIT31,
RESERVED_SWITCH_1_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_1_BIT1,
RESERVED_SWITCH_1_BIT2,
RESERVED_SWITCH_1_BIT3,
RESERVED_SWITCH_1_BIT4,
RESERVED_SWITCH_1_BIT5,
RESERVED_SWITCH_1_BIT6,
RESERVED_SWITCH_1_BIT7,
RESERVED_SWITCH_1_BIT8,
RESERVED_SWITCH_1_BIT9,
RESERVED_SWITCH_1_BIT10,
RESERVED_SWITCH_1_BIT11,
RESERVED_SWITCH_1_BIT12,
RESERVED_SWITCH_1_BIT13,
RESERVED_SWITCH_1_BIT14,
RESERVED_SWITCH_1_BIT15,
RESERVED_SWITCH_1_BIT16,
RESERVED_SWITCH_1_BIT17,
RESERVED_SWITCH_1_BIT18,
RESERVED_SWITCH_1_BIT19,
RESERVED_SWITCH_1_BIT20,
RESERVED_SWITCH_1_BIT21,
RESERVED_SWITCH_1_BIT22,
RESERVED_SWITCH_1_BIT23,
RESERVED_SWITCH_1_BIT24,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_1_BIT25,
RESERVED_SWITCH_1_BIT26,
RESERVED_SWITCH_1_BIT27,
RESERVED_SWITCH_1_BIT28,
RESERVED_SWITCH_1_BIT29,
RESERVED_SWITCH_1_BIT30,
RESERVED_SWITCH_1_BIT31,
RESERVED_SWITCH_1_BIT32
Default Value:
RESERVED_SWITCH_1_BIT1:0,RESERVED_SWITCH_1_BI
T2:0,RESERVED_SWITCH_1_BIT3:0,RESERVED_SWITCH_
1_BIT4:0,RESERVED_SWITCH_1_BIT5:0,RESERVED_SWI
TCH_1_BIT6:0,RESERVED_SWITCH_1_BIT7:0,RESERVED
_SWITCH_1_BIT8:0,RESERVED_SWITCH_1_BIT9:0,RESER
VED_SWITCH_1_BIT10:0,RESERVED_SWITCH_1_BIT11:0,
RESERVED_SWITCH_1_BIT12:0,RESERVED_SWITCH_1_B
IT13:0,RESERVED_SWITCH_1_BIT14:0,RESERVED_SWIT
CH_1_BIT15:0,RESERVED_SWITCH_1_BIT16:0,RESERVED
_SWITCH_1_BIT17:0,RESERVED_SWITCH_1_BIT18:0,RES
ERVED_SWITCH_1_BIT19:0,RESERVED_SWITCH_1_BIT2
0:0,RESERVED_SWITCH_1_BIT21:0,RESERVED_SWITCH_
1_BIT22:0,RESERVED_SWITCH_1_BIT23:0,RESERVED_S
WITCH_1_BIT24:0,RESERVED_SWITCH_1_BIT25:0,RESER
VED_SWITCH_1_BIT26:0,RESERVED_SWITCH_1_BIT27:0,
RESERVED_SWITCH_1_BIT28:0,RESERVED_SWITCH_1_B
IT29:0,RESERVED_SWITCH_1_BIT30:0,RESERVED_SWIT
CH_1_BIT31:0,RESERVED_SWITCH_1_BIT32:0
OCO W e
V RF Inte
D- r-
02 RA
03 T
06 Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
Penalt B ADD W Inte Meaning: Length of a penalty timer for inter-RAT handover
yTime S UCE RF r- failures due to physical channel failures. During the period
ForPh C LLIN D- RA specified by "PenaltyTimeForPhyChFail", the UE is not allowed
yChFa 6 TERR 02 T to make inter-RAT handover attempts. For details about the
il 9 ATH 03 Han physical channel failure, see 3GPP TS 25.331.
0 OCO 05 dov GUI Value Range: 0~65535
0 V W er Unit: s
MOD RF Bas
Actual Value Range: 0~65535
UCE D- ed
on Default Value: 30
LLIN 02
TERR 03 Ser
ATH 06 vice
OCO W
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
V RF
D-
02
03
03
Penalt B ADD W Inte Meaning: Length of a penalty timer for inter-RAT handover
yTime S UCE RF r- failures due to physical channel failures. During the period
ForPh C LLIN D- RA specified by "PenaltyTimeForPhyChFail", the UE is not allowed
yChFa 6 TERR 02 T to make inter-RAT handover attempts. For details about the
il 9 ATH 03 Han physical channel failure, see 3GPP TS 25.331.
1 OCO 05 dov GUI Value Range: 0~65535
0 V W er Unit: s
MOD RF Bas
Actual Value Range: 0~65535
UCE D- ed
on Default Value: 30
LLIN 02
TERR 03 Ser
ATH 06 vice
OCO W
V RF
D-
02
03
03
one RLS. When this switch is turned on, the UE uses the values
of the two parameters that are for UEs having only one RLS. 23.
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWITCH:
Whether to enable a RELOCATION REQUIRED message to
contain the IE calculationTimeForCiphering. When this switch is
turned on, static relocation request messages contain the IE
calculationTimeForCiphering. 24.
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH: Whether to
trigger the DRD procedure and channel switchover from E-DCH
or HS-DSCH to DCH when messages transmitted over the Uu
and Iub interfaces do not arrive in time. When this switch is
turned off, the DRD procedure and channel switchover from E-
DCH or HS-DSCH to DCH are not triggered if messages
transmitted over the Uu and Iub interfaces do not arrive in time.
When this switch is turned on, the DRD procedure and channel
switchover from E-DCH or HS-DSCH to DCH are triggered if
messages transmitted over the Uu and Iub interfaces do not
arrive in time. 25.
PERFENH_CELL_CACLOAD_BROADCAST_AMEND:
Whether to consider CE or code resource usage when
determining the resource status of a cell whose serving boards or
CP sub-systems are different from those of its neighboring cells.
When this switch is turned on, the RNC determines the resource
status of such a cell based on power, CE, and code resource
usage. If power, CE, or code resources in a cell become
congested, the RNC determines that the cell experiences
resource congestion. When this switch is turned off, the RNC
determines the resource status of such a cell based on power
resource usage only. 26.
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH: When this
switch is turned on, candidate cells are ranked by
"InterFreqMeasQuantity" (in the "ADD
UCELLMBDRINTERFREQ" command) for MBDR, and the
cell with the best signal quality is selected as the target cell.
When this switch is turned off, candidate cells are not ranked by
InterFreqMeasQuantity for MBDR. 27.
PERFENH_RRC_DRD_PREADMISSION_SWITCH: Whether
the RNC makes a pre-admission decision on intra-RAT DRDs or
redirections during an RRC connection setup. When this switch
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
PERFENH_OLPC_TMPLT_SWITCH,
PERFENH_AMR_SP_TMPLT_SWITCH,
PERFENH_INTRAFREQ_MC_TMPLT_SWITCH,
PERFENH_INTERRAT_PENALTY_50_SWITCH,
PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH,
PERFENH_HSUPA_TTI2_ENHANCE_SWITCH,
PERFENH_UU_P2D_CUC_OPT_SWITCH,
PERFENH_RL_RECFG_SIR_CONSIDER_SWITCH,
PERFENH_RRC_REDIR_PROTECT_SWITCH,
PERFENH_H2F_OPT_SWITCH,
PERFENH_PSTRAFFIC_P2H_SWITCH,
PERFENH_VIP_USER_PCHR_MR_SWITCH,
PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH,
PERFENH_CELL_HSUPA_CAP_CHANGE_OPT_SWITCH,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWITCH,
PERFENH_DOWNLOAD_ENHANCE_SWITCH,
PERFENH_OLPC_BLER_COEF_ADJUST,
PERFENH_EMG_AGPS_MC_DELAY_SWITCH,
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITCH,
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWITCH,
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH,
PERFENH_CELL_CACLOAD_BROADCAST_AMEND,
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH,
PERFENH_RRC_DRD_PREADMISSION_SWITCH,
PERFENH_RRC_WEAK_REDIR_SWITCH,
PERFENH_L2U_CSFB_COMMCALL_SWITCH,
PERFENH_DLBLINDDETECT_WHEN_ONLYSRBONDCH,
PERFENH_DLBLINDDETECT_WHEN_SRBAMRONDCH,
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT
Default Value:
PERFENH_AMR_SPEC_BR_SWITCH:1,PERFENH_AMR_T
MPLT_SWITCH:1,PERFENH_SRB_TMPLT_SWITCH:1,PER
FENH_OLPC_TMPLT_SWITCH:1,PERFENH_AMR_SP_TMP
LT_SWITCH:1,PERFENH_INTRAFREQ_MC_TMPLT_SWIT
CH:1,PERFENH_INTERRAT_PENALTY_50_SWITCH:1,PER
FENH_SRB_OVER_HSUPA_TTI10_SWITCH:0,PERFENH_H
SUPA_TTI2_ENHANCE_SWITCH:0,PERFENH_UU_P2D_C
UC_OPT_SWITCH:0,PERFENH_RL_RECFG_SIR_CONSIDE
R_SWITCH:1,PERFENH_RRC_REDIR_PROTECT_SWITCH:
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
0,PERFENH_H2F_OPT_SWITCH:0,PERFENH_PSTRAFFIC_
P2H_SWITCH:0,PERFENH_VIP_USER_PCHR_MR_SWITC
H:0,PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH:0,PE
RFENH_CELL_HSUPA_CAP_CHANGE_OPT_SWITCH:0,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWITCH:0,PE
RFENH_DOWNLOAD_ENHANCE_SWITCH:0,PERFENH_O
LPC_BLER_COEF_ADJUST:1,PERFENH_EMG_AGPS_MC_
DELAY_SWITCH:0,PERFENH_MULTI_RLS_CQI_PARA_OP
T_SWITCH:0,PERFENH_RELOC_IE_CALCTIMEFORCIP_S
WITCH:0,PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH:0,
PERFENH_CELL_CACLOAD_BROADCAST_AMEND:1,PE
RFENH_MBDR_TARCELLSEL_OPT_SWITCH:0,PERFENH_
RRC_DRD_PREADMISSION_SWITCH:0,PERFENH_RRC_
WEAK_REDIR_SWITCH:0,PERFENH_L2U_CSFB_COMMC
ALL_SWITCH:0,PERFENH_DLBLINDDETECT_WHEN_ON
LYSRBONDCH:0,PERFENH_DLBLINDDETECT_WHEN_SR
BAMRONDCH:0,PERFENH_R6_HSUPA_TTI_10MSTO2MS_
LIMIT:0
calculationTimeForCiphering. 24.
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH: Whether to
trigger the DRD procedure and channel switchover from E-DCH
or HS-DSCH to DCH when messages transmitted over the Uu
and Iub interfaces do not arrive in time. When this switch is
turned off, the DRD procedure and channel switchover from E-
DCH or HS-DSCH to DCH are not triggered if messages
transmitted over the Uu and Iub interfaces do not arrive in time.
When this switch is turned on, the DRD procedure and channel
switchover from E-DCH or HS-DSCH to DCH are triggered if
messages transmitted over the Uu and Iub interfaces do not
arrive in time. 25.
PERFENH_CELL_CACLOAD_BROADCAST_AMEND:
Whether to consider CE or code resource usage when
determining the resource status of a cell whose serving boards or
CP sub-systems are different from those of its neighboring cells.
When this switch is turned on, the RNC determines the resource
status of such a cell based on power, CE, and code resource
usage. If power, CE, or code resources in a cell become
congested, the RNC determines that the cell experiences
resource congestion. When this switch is turned off, the RNC
determines the resource status of such a cell based on power
resource usage only. 26.
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH: When this
switch is turned on, candidate cells are ranked by
"InterFreqMeasQuantity" (in the "ADD
UCELLMBDRINTERFREQ" command) for MBDR, and the
cell with the best signal quality is selected as the target cell.
When this switch is turned off, candidate cells are not ranked by
InterFreqMeasQuantity for MBDR. 27.
PERFENH_RRC_DRD_PREADMISSION_SWITCH: Whether
the RNC makes a pre-admission decision on intra-RAT DRDs or
redirections during an RRC connection setup. When this switch
is turned on, the RNC makes a pre-admission decision on intra-
RAT DRDs or redirections during an RRC connection setup.
When this switch is turned off, the RNC does not make a pre-
admission decision on intra-RAT DRDs or redirections during an
RRC connection setup. 28.
PERFENH_RRC_WEAK_REDIR_SWITCH: Whether to
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
PERFENH_OLPC_TMPLT_SWITCH,
PERFENH_AMR_SP_TMPLT_SWITCH,
PERFENH_INTRAFREQ_MC_TMPLT_SWITCH,
PERFENH_INTERRAT_PENALTY_50_SWITCH,
PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH,
PERFENH_HSUPA_TTI2_ENHANCE_SWITCH,
PERFENH_UU_P2D_CUC_OPT_SWITCH,
PERFENH_RL_RECFG_SIR_CONSIDER_SWITCH,
PERFENH_RRC_REDIR_PROTECT_SWITCH,
PERFENH_H2F_OPT_SWITCH,
PERFENH_PSTRAFFIC_P2H_SWITCH,
PERFENH_VIP_USER_PCHR_MR_SWITCH,
PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH,
PERFENH_CELL_HSUPA_CAP_CHANGE_OPT_SWITCH,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWITCH,
PERFENH_DOWNLOAD_ENHANCE_SWITCH,
PERFENH_OLPC_BLER_COEF_ADJUST,
PERFENH_EMG_AGPS_MC_DELAY_SWITCH,
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITCH,
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWITCH,
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH,
PERFENH_CELL_CACLOAD_BROADCAST_AMEND,
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH,
PERFENH_RRC_DRD_PREADMISSION_SWITCH,
PERFENH_RRC_WEAK_REDIR_SWITCH,
PERFENH_L2U_CSFB_COMMCALL_SWITCH,
PERFENH_DLBLINDDETECT_WHEN_ONLYSRBONDCH,
PERFENH_DLBLINDDETECT_WHEN_SRBAMRONDCH,
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT
Unit: None
Actual Value Range: PERFENH_AMR_SPEC_BR_SWITCH,
PERFENH_AMR_TMPLT_SWITCH,
PERFENH_SRB_TMPLT_SWITCH,
PERFENH_OLPC_TMPLT_SWITCH,
PERFENH_AMR_SP_TMPLT_SWITCH,
PERFENH_INTRAFREQ_MC_TMPLT_SWITCH,
PERFENH_INTERRAT_PENALTY_50_SWITCH,
PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH,
PERFENH_HSUPA_TTI2_ENHANCE_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
PERFENH_UU_P2D_CUC_OPT_SWITCH,
PERFENH_RL_RECFG_SIR_CONSIDER_SWITCH,
PERFENH_RRC_REDIR_PROTECT_SWITCH,
PERFENH_H2F_OPT_SWITCH,
PERFENH_PSTRAFFIC_P2H_SWITCH,
PERFENH_VIP_USER_PCHR_MR_SWITCH,
PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH,
PERFENH_CELL_HSUPA_CAP_CHANGE_OPT_SWITCH,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWITCH,
PERFENH_DOWNLOAD_ENHANCE_SWITCH,
PERFENH_OLPC_BLER_COEF_ADJUST,
PERFENH_EMG_AGPS_MC_DELAY_SWITCH,
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITCH,
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWITCH,
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH,
PERFENH_CELL_CACLOAD_BROADCAST_AMEND,
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH,
PERFENH_RRC_DRD_PREADMISSION_SWITCH,
PERFENH_RRC_WEAK_REDIR_SWITCH,
PERFENH_L2U_CSFB_COMMCALL_SWITCH,
PERFENH_DLBLINDDETECT_WHEN_ONLYSRBONDCH,
PERFENH_DLBLINDDETECT_WHEN_SRBAMRONDCH,
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT
Default Value:
PERFENH_AMR_SPEC_BR_SWITCH:1,PERFENH_AMR_T
MPLT_SWITCH:1,PERFENH_SRB_TMPLT_SWITCH:1,PER
FENH_OLPC_TMPLT_SWITCH:1,PERFENH_AMR_SP_TMP
LT_SWITCH:1,PERFENH_INTRAFREQ_MC_TMPLT_SWIT
CH:1,PERFENH_INTERRAT_PENALTY_50_SWITCH:1,PER
FENH_SRB_OVER_HSUPA_TTI10_SWITCH:0,PERFENH_H
SUPA_TTI2_ENHANCE_SWITCH:0,PERFENH_UU_P2D_C
UC_OPT_SWITCH:0,PERFENH_RL_RECFG_SIR_CONSIDE
R_SWITCH:1,PERFENH_RRC_REDIR_PROTECT_SWITCH:
0,PERFENH_H2F_OPT_SWITCH:0,PERFENH_PSTRAFFIC_
P2H_SWITCH:0,PERFENH_VIP_USER_PCHR_MR_SWITC
H:0,PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH:0,PE
RFENH_CELL_HSUPA_CAP_CHANGE_OPT_SWITCH:0,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWITCH:0,PE
RFENH_DOWNLOAD_ENHANCE_SWITCH:0,PERFENH_O
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
LPC_BLER_COEF_ADJUST:1,PERFENH_EMG_AGPS_MC_
DELAY_SWITCH:0,PERFENH_MULTI_RLS_CQI_PARA_OP
T_SWITCH:0,PERFENH_RELOC_IE_CALCTIMEFORCIP_S
WITCH:0,PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH:0,
PERFENH_CELL_CACLOAD_BROADCAST_AMEND:1,PE
RFENH_MBDR_TARCELLSEL_OPT_SWITCH:0,PERFENH_
RRC_DRD_PREADMISSION_SWITCH:0,PERFENH_RRC_
WEAK_REDIR_SWITCH:0,PERFENH_L2U_CSFB_COMMC
ALL_SWITCH:0,PERFENH_DLBLINDDETECT_WHEN_ON
LYSRBONDCH:0,PERFENH_DLBLINDDETECT_WHEN_SR
BAMRONDCH:0,PERFENH_R6_HSUPA_TTI_10MSTO2MS_
LIMIT:0
r- CN. 0: This switch is turned off. The RNC does not send an MM
RA NULL message to the CS CN.
T 10)FD_PCH_IUR_CS_OPT_SWITCH CS paging message
Han processing switch for UEs in the CELL_PCH or URA_PCH
dov state that support fast dormancy on the drift radio network
er controller (DRNC) side. 1: This switch is turned on. The SRNC
Bas instructs these UEs to transition to the CELL_DCH state and to
ed establish CS services when these UEs receive a CS paging
on message. 0: This switch is turned off. The SRNC releases the
Cov connection of these UEs when these UEs receive a CS paging
erag message.
e 11)CELLUPT_T314_T315_TIMEOUT_OPT_SWITCH
Inte Whether the RNC releases the connection of a UE in a state
r other than CELL_DCH when the T314/T315 timer in the cell
Fre update message received by the UE expires. 1: This switch is
que turned on. The RNC continues with the cell update processing
ncy when the T314/T315 timer in the cell update message expires. 0:
Har This switch is turned off. The RNC abnormally releases the
d connection of the UE when the T314/T315 timer in the cell
Han update message expires. 12)
dov CS_HHO_ASYNC_CTRL_SWITCH(Asynchronous
er Reconfigure Switch for CS HHO) 1: This switch is turned on.
Bas The RNC does not put the activation time information element
ed (IE) in the hard handover configuration message for CS services.
on After receiving the message, the UE immediately activates the
DL configuration. 0: This switch is turned off. The RNC puts the
Qo activation time IE in the hard handover configuration message
S for CS services. After receiving the message, the UE activates
Inte the configuration at the specified activation time. 13)
r- PS_HHO_ASYNC_CTRL_SWITCH(Asynchronous
RA Reconfigure Switch for PS HHO) 1: This switch is turned on.
T The RNC does not put the activation time information element
Han (IE) in the hard handover configuration message for PS services.
dov After receiving the message, the UE immediately activates the
er configuration. 0: This switch is turned off. The RNC puts the
Bas activation time IE in the hard handover configuration message
ed for PS services. After receiving the message, the UE activates the
on configuration at the specified activation time. 14)
Ser IUR_HHO_ASYNC_CTRL_SWITCH(Asynchronous
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
vice Reconfigure Switch for Iur HHO) 1: This switch is turned on.
Inte The RNC does not put the activation time information element
r- (IE) in the hard handover configuration message across the Iur
RA interface. After receiving the message, the UE immediately
T activates the configuration. 0: This switch is turned off. The
Han RNC puts the activation time IE in the hard handover
dov configuration message across the Iur interface. After receiving
er the message, the UE activates the configuration at the specified
Bas activation time. 15) R8_UE_SEL_DPUE_SWITCH (Switch for
ed Preferentially Allocating DPUe Resources to UEs That Comply
on with 3GPP Release 8 or Later) 1: This switch is turned on. The
Loa RNC preferentially allocates DPUe resources in any subrack to
d UEs that comply with 3GPP Release 8 or later. 0: This switch is
turned off. The RNC preferentially allocates DPU resources in
the subrack that the UEs access to UEs that comply with 3GPP
Release 8 or later. The RNC allocates DPU resources in other
subracks only when the amount of consumed DPU resources in
this subrack exceeds a preset threshold for inter-subrack resource
sharing. 16) F2P_DATATRANS_OPTIMIZE_SWITCH(Switch
for Optimized Data Transmission before a State Transition from
CELL_FACH to CELL_PCH or URA_PCH) Whether the RNC
queries the RLC state before and after a UE moves from the
CELL_FACH state to the CELL_PCH or URA_PCH state due to
event 4B. A UE in the CELL_FACH state can move to the
CELL_PCH or URA_PCH state even when there is downlink
data transmission for the UE. When this occurs, data packets are
suspended on the RNC side. This switch is introduced to solve
this problem. 1: This switch is turned on. The RNC queries the
RLC state before a UE moves from the CELL_FACH state to the
CELL_PCH or URA_PCH state due to event 4B. If the state
query fails, the UE does not perform the state transition. If the
state query succeeds, the UE continues with the state transition.
The RNC queries the RLC state again after the state transition is
complete and before the L2 link is deactivated. If there is SRB3,
SRB4, or TRB data to be transmitted to the UE on the RLC, the
paging procedure is triggered. 0: This switch is turned off. The
original state transition from CELL_FACH to CELL_PCH or
URA_PCH is used. This parameter is an advanced parameter. To
modify this parameter, contact Huawei Customer Service Center
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
switch is turned on. The RNC reestablishes a radio link (RL) for
the UE during a radio bearer (RB) setup CELL_DCH-to-
CELL_DCH (D2D) procedure under the following conditions:
The RNC detects a signaling radio bearer (SRB) reset at layer 2
(L2) or all uplink RLs for the UE are out of synchronization
upon expiration of the RL Restore timer and the UE has received
the RADIO BEARER SETUP message. The UE has no response
to the RNC after the RNC sends UE a RADIO BEARER SETUP
message. The switch RB_SETUP_RL_REEST_SWITCH under
"PROCESSSWITCH4" in the "SET URRCTRLSWITCH"
command should be turned on. And it is recommended that the
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH and
RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH in
the "OptimizationSwitch4" parameter in the "SET
URRCTRLSWITCH" command be set to on. 0: This switch is
turned off. The RNC does not reestablish the radio link for the
UE under the preceding conditions.
21)RAB_SETUPMOD_CNT_FIX_SWITCH Whether to correct
the methods for measuring the counters related to RAB setup or
reconfiguration failures of UEs in the CELL_FACH state. The
RAB setup or reconfiguration is triggered by the F2F or F2D
state transition. This switch is turned off by default. 1: This
switch is turned on. The measurement methods of these counters
are corrected based on the measurement points. 0: This switch is
turned off. The measurement methods of these counters remain
unchanged.
22)PCH_UE_RLC_UNRECOVERABLEERROR_SWITCH
Whether to reestablish the call for the UE that sends a CELL
UPDATE message with the cause value "RLC unrecoverable
error" in the CELL_PCH or URA_PCH state. 1: This switch is
turned on. The RNC reestablishes the call for the UE that sends a
CELL UPDATE message with the cause value "RLC
unrecoverable error" in the CELL_PCH or URA_PCH state. 0:
This switch is turned off. The RNC does not reestablish the call
for the UE that sends a CELL UPDATE message with the cause
value "RLC unrecoverable error" in the CELL_PCH or
URA_PCH state.
23)FAST_RETURN_LTE_BY_CELL_SELECT_SWITCH
Whether a UMTS/LTE UE performs fast cell reselection. 1: This
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
R8_UE_SEL_DPUE_SWITCH,
F2P_DATATRANS_OPTIMIZE_SWITCH,
IRATHO_HOCANCEL_RL_REEST_SWITCH,
TRB_RESET_RL_REEST_SWITCH,
RB_REL_RL_REEST_SWITCH,
RB_SETUP_ENHANCE_RL_REEST_SWITCH,
RAB_SETUPMOD_CNT_FIX_SWITCH,
PCH_UE_RLC_UNRECOVERABLEERROR_SWITCH,
FAST_RETURN_LTE_BY_CELL_SELECT_SWITCH,
UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH,
PHYCHRECFG_ENH_RL_REEST_SWITCH,
RBRECFG_ENH_RL_REEST_SWITCH,
SMC_STOP_RLC_SWITCH,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWITCH,
CMP_IU_QOS_GTP_PDU_SN_SWITCH,
DL_TRB_RESET_BUFF_SWITCH,
RRC_CELLFACH_DL_TRB_RESET_TO_F2D_SWITCH,
RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH
Unit: None
Actual Value Range:
PS_F2D_OVERLAP_CELLUPT_SWITCH,
AMR_HHO_FAIL_ROLLBACK_SWITCH,
PHY_RECFG_REEST_SWITCH, IUR_RL_REEST_SWITCH,
RB_SETUP_RL_REEST_SWITCH,
RRC_CONN_SETUP_OPT_SWITCH,
TCP_ACK_ACCELERATOR_SWITCH,
RRC_CELLFACH_TRB_RESET_TO_F2D_SWITCH,
SEND_MSG_NULL_SWITCH,
FD_PCH_IUR_CS_OPT_SWITCH,
CELLUPT_T314_T315_TIMEOUT_OPT_SWITCH,
CS_HHO_ASYNC_CTRL_SWITCH,
PS_HHO_ASYNC_CTRL_SWITCH,
IUR_HHO_ASYNC_CTRL_SWITCH,
R8_UE_SEL_DPUE_SWITCH,
F2P_DATATRANS_OPTIMIZE_SWITCH,
IRATHO_HOCANCEL_RL_REEST_SWITCH,
TRB_RESET_RL_REEST_SWITCH,
RB_REL_RL_REEST_SWITCH,
RB_SETUP_ENHANCE_RL_REEST_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RAB_SETUPMOD_CNT_FIX_SWITCH,
PCH_UE_RLC_UNRECOVERABLEERROR_SWITCH,
FAST_RETURN_LTE_BY_CELL_SELECT_SWITCH,
UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH,
PHYCHRECFG_ENH_RL_REEST_SWITCH,
RBRECFG_ENH_RL_REEST_SWITCH,
SMC_STOP_RLC_SWITCH,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWITCH,
CMP_IU_QOS_GTP_PDU_SN_SWITCH,
DL_TRB_RESET_BUFF_SWITCH,
RRC_CELLFACH_DL_TRB_RESET_TO_F2D_SWITCH,
RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH
Default Value:
PS_F2D_OVERLAP_CELLUPT_SWITCH:0,AMR_HHO_FAI
L_ROLLBACK_SWITCH:0,PHY_RECFG_REEST_SWITCH:
0,IUR_RL_REEST_SWITCH:0,RB_SETUP_RL_REEST_SWI
TCH:0,RRC_CONN_SETUP_OPT_SWITCH:0,TCP_ACK_AC
CELERATOR_SWITCH:0,RRC_CELLFACH_TRB_RESET_T
O_F2D_SWITCH:0,SEND_MSG_NULL_SWITCH:0,FD_PCH
_IUR_CS_OPT_SWITCH:0,CELLUPT_T314_T315_TIMEOU
T_OPT_SWITCH:0,CS_HHO_ASYNC_CTRL_SWITCH:0,PS_
HHO_ASYNC_CTRL_SWITCH:0,IUR_HHO_ASYNC_CTRL
_SWITCH:0,R8_UE_SEL_DPUE_SWITCH:0,F2P_DATATRA
NS_OPTIMIZE_SWITCH:0,IRATHO_HOCANCEL_RL_REES
T_SWITCH:0,TRB_RESET_RL_REEST_SWITCH:0,RB_REL
_RL_REEST_SWITCH:0,RB_SETUP_ENHANCE_RL_REES
T_SWITCH:0,RAB_SETUPMOD_CNT_FIX_SWITCH:0,PCH
_UE_RLC_UNRECOVERABLEERROR_SWITCH:0,FAST_R
ETURN_LTE_BY_CELL_SELECT_SWITCH:0,UL_DUAL_M
ODE_UE_D2P_OR_D2I_SWITCH:0,PHYCHRECFG_ENH_R
L_REEST_SWITCH:0,RBRECFG_ENH_RL_REEST_SWITC
H:0,SMC_STOP_RLC_SWITCH:1,GTP_SN_IN_RAB_REL_I
NIT_BY_UTRAN_SWITCH:1,CMP_IU_QOS_GTP_PDU_SN
_SWITCH:0,DL_TRB_RESET_BUFF_SWITCH:0,RRC_CELL
FACH_DL_TRB_RESET_TO_F2D_SWITCH:0,RAB_ASS_M
OD_TNL_ADDR_SUP_SWITCH:1
h4 C CTRL D- 13.6 Services) 1: This switch is turned on. The RNC supports rollback
6 SWIT 01 /27. caused by failed hard handovers of CS AMR speech services. It
9 CH 05 2Kb is recommended that the timer T312 be set to 1 second (SET
1 10 ps UCONNMODETIMER: T312=1;) before turning on this switch.
0 W RR If the timer T312 is not set to 1 second, AMR noise will occur on
RF C some UEs. If the AMRC feature is enabled, the RNC supports
D- Con the hard handover failure rollback of only for 12.2 kbit/s
01 nect narrowband AMR services. 0: This switch is turned off. The
06 ion RNC does not support rollback caused by failed hard handovers
09 and of CS AMR speech services, leading to call drops. 2)
02 Rad RRC_CONN_SETUP_OPT_SWITCH (RRC CONNECTION
W io SETUP Message Optimization Switch) Whether optimization of
RF Acc the RRC CONNECTION SETUP message takes effect. 1: This
D- ess switch is turned on. Optimization of the RRC CONNECTION
01 Bea SETUP message takes effect. If the IE RLC info under SRB3 or
01 rer SRB4 in the RRC CONNECTION SETUP message contains the
01 Esta same information as that under SRB2, the RNC replaces the IE
blis RLC info under SRB3 or SRB4 with the IE same as RB:0x2(2)
W
hme to shorten the length of the message. 0: This switch is turned off.
RF
nt The RNC does not replace the IE RLC info under SRB3 or
D-
and SRB4 in the RRC CONNECTION SETUP message. 3)
14
Rel PS_F2D_OVERLAP_CELLUPT_SWITCH (Switch for
02
ease Simultaneous PS Service Setup F2D and Cell Update
26
Co Procedures) During the PS service setup, the RNC undoes a
W
mbi CELL_FACH-to-CELL_DCH (F2D for short) procedure when it
RF
nati receives a Cell Update message with the cause value "cell
D-
on reselection" during the F2D procedure. 1: This switch is turned
14 on. The RNC temporarily does not send the
of
01
One RANAP_RAB_ASSIGNMENT_RESP message to the CN after
03
CS the F2D procedure is undone and waits until the Cell Update
W Ser message is processed and the PS service is set up successfully. 0:
RF vice This switch is turned off. The RNC directly responds to the CN
D- and with a RANAP_RAB_ASSIGNMENT_RESP message with the
02 One cause value "IU_UNSPEC_FAIL" after the F2D procedure is
04 PS undone, indicating that the PS service fails to be set up. 4)
00 Ser TCP_ACK_ACCELERATOR_SWITCH (Switch for Throughput
02 vice Increase in the Case of Simultaneous uplink and downlink
W 3G Transmissions) This switch is turned on to increase the total
RF PP throughput in the uplink and downlink only when uplink and
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
turned on. The RNC reestablishes a radio link (RL) for the UE
during a PS radio bearer (RB) release procedure under the
following conditions: The RNC detects a signaling radio bearer
(SRB) reset at layer 2 (L2) or all uplink RLs for the UE are out
of synchronization upon expiration of the RL Restore timer or
UE has no response to RNC after RNC sends UE a RADIO
BEARER RELEASE message. The UE has both CS RAB and
PS RAB. The UE is in CELL_DCH state. It is recommended that
this switch be used together with the
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH in the
"OptimizationSwitch4" parameter in the "SET
URRCTRLSWITCH" command. 0: This switch is turned off.
The RNC does not reestablish the radio link for the UE under the
preceding conditions.
19)RB_SETUP_ENHANCE_RL_REEST_SWITCH(Switch for
Enhanced RL Reestablishments During an RB setup) 1: This
switch is turned on. The RNC reestablishes a radio link (RL) for
the UE during a radio bearer (RB) setup CELL_DCH-to-
CELL_DCH (D2D) procedure under the following conditions:
The RNC detects a signaling radio bearer (SRB) reset at layer 2
(L2) or all uplink RLs for the UE are out of synchronization
upon expiration of the RL Restore timer and the UE has received
the RADIO BEARER SETUP message. The UE has no response
to the RNC after the RNC sends UE a RADIO BEARER SETUP
message. The switch RB_SETUP_RL_REEST_SWITCH under
"PROCESSSWITCH4" in the "SET URRCTRLSWITCH"
command should be turned on. And it is recommended that the
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH and
RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH in
the "OptimizationSwitch4" parameter in the "SET
URRCTRLSWITCH" command be set to on. 0: This switch is
turned off. The RNC does not reestablish the radio link for the
UE under the preceding conditions.
20)RAB_SETUPMOD_CNT_FIX_SWITCH Whether to correct
the methods for measuring the counters related to RAB setup or
reconfiguration failures of UEs in the CELL_FACH state. The
RAB setup or reconfiguration is triggered by the F2F or F2D
state transition. This switch is turned off by default. 1: This
switch is turned on. The measurement methods of these counters
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RB_SETUP_RL_REEST_SWITCH,
RRC_CONN_SETUP_OPT_SWITCH,
TCP_ACK_ACCELERATOR_SWITCH,
RRC_CELLFACH_TRB_RESET_TO_F2D_SWITCH,
SEND_MSG_NULL_SWITCH,
FD_PCH_IUR_CS_OPT_SWITCH,
CELLUPT_T314_T315_TIMEOUT_OPT_SWITCH,
CS_HHO_ASYNC_CTRL_SWITCH,
PS_HHO_ASYNC_CTRL_SWITCH,
IUR_HHO_ASYNC_CTRL_SWITCH,
F2P_DATATRANS_OPTIMIZE_SWITCH,
IRATHO_HOCANCEL_RL_REEST_SWITCH,
TRB_RESET_RL_REEST_SWITCH,
RB_REL_RL_REEST_SWITCH,
RB_SETUP_ENHANCE_RL_REEST_SWITCH,
RAB_SETUPMOD_CNT_FIX_SWITCH,
PCH_UE_RLC_UNRECOVERABLEERROR_SWITCH,
FAST_RETURN_LTE_BY_CELL_SELECT_SWITCH,
UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH,
PHYCHRECFG_ENH_RL_REEST_SWITCH,
RBRECFG_ENH_RL_REEST_SWITCH,
SMC_STOP_RLC_SWITCH,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWITCH,
CMP_IU_QOS_GTP_PDU_SN_SWITCH,
DL_TRB_RESET_BUFF_SWITCH,
RRC_CELLFACH_DL_TRB_RESET_TO_F2D_SWITCH,
RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH
Default Value:
PS_F2D_OVERLAP_CELLUPT_SWITCH:0,AMR_HHO_FAI
L_ROLLBACK_SWITCH:0,PHY_RECFG_REEST_SWITCH:
0,IUR_RL_REEST_SWITCH:0,RB_SETUP_RL_REEST_SWI
TCH:0,RRC_CONN_SETUP_OPT_SWITCH:0,TCP_ACK_AC
CELERATOR_SWITCH:0,RRC_CELLFACH_TRB_RESET_T
O_F2D_SWITCH:0,SEND_MSG_NULL_SWITCH:0,FD_PCH
_IUR_CS_OPT_SWITCH:0,CELLUPT_T314_T315_TIMEOU
T_OPT_SWITCH:0,CS_HHO_ASYNC_CTRL_SWITCH:0,PS_
HHO_ASYNC_CTRL_SWITCH:0,IUR_HHO_ASYNC_CTRL
_SWITCH:0,F2P_DATATRANS_OPTIMIZE_SWITCH:0,IRAT
HO_HOCANCEL_RL_REEST_SWITCH:0,TRB_RESET_RL_
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
REEST_SWITCH:0,RB_REL_RL_REEST_SWITCH:0,RB_SE
TUP_ENHANCE_RL_REEST_SWITCH:0,RAB_SETUPMOD
_CNT_FIX_SWITCH:0,PCH_UE_RLC_UNRECOVERABLEE
RROR_SWITCH:0,FAST_RETURN_LTE_BY_CELL_SELEC
T_SWITCH:0,UL_DUAL_MODE_UE_D2P_OR_D2I_SWITC
H:0,PHYCHRECFG_ENH_RL_REEST_SWITCH:0,RBRECFG
_ENH_RL_REEST_SWITCH:0,SMC_STOP_RLC_SWITCH:1,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWITCH:1,CMP
_IU_QOS_GTP_PDU_SN_SWITCH:0,DL_TRB_RESET_BUF
F_SWITCH:0,RRC_CELLFACH_DL_TRB_RESET_TO_F2D_
SWITCH:0,RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH:1
SoftFa B SET W Intr Meaning: Whether to trigger state transitions from CELL_DCH
ilD2F S UINT RF a to CELL_FACH (D2F for short) if soft handover-based service
Switc C RAF D- RN admission fails. When this parameter is set to ON, failures in soft
h 6 REQ 02 C handover-based service admission trigger D2F transitions for
9 HO 02 Soft R99 non-real-time PS services if the signal quality of the target
0 02 Han cell is greater than the sum of the signal quality of the best cell
0 dov plus the "SoftFailD2FOffset" parameter value. When this
er parameter is set to OFF, D2F transitions are not triggered.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
SoftFa B SET W Intr Meaning: Whether to trigger state transitions from CELL_DCH
ilD2F S UINT RF a to CELL_FACH (D2F for short) if soft handover-based service
Switc C RAF D- RN admission fails. When this parameter is set to ON, failures in soft
h 6 REQ 02 C handover-based service admission trigger D2F transitions for
9 HO 02 Soft R99 non-real-time PS services if the signal quality of the target
1 02 Han cell is greater than the sum of the signal quality of the best cell
0 dov plus the "SoftFailD2FOffset" parameter value. When this
er parameter is set to OFF, D2F transitions are not triggered.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
SoftFa B SET W Intr Meaning: Signal quality offset of the target cell relative to the
ilD2F S UINT RF a best cell when a D2F transition is triggered due to a failure in
Offset C RAF D- RN soft handover-based service admission. Only when the signal
6 REQ 02 C quality of the target cell is greater than the sum of the signal
9 HO 02 Soft quality of the best cell plus this parameter value, a D2F transition
0 02 Han can be triggered if soft handover-based service admission fails.
0 dov GUI Value Range: -29~29
er Unit: 0.5dB
Actual Value Range: -14.5~14.5
Default Value: 4
SoftFa B SET W Intr Meaning: Signal quality offset of the target cell relative to the
ilD2F S UINT RF a best cell when a D2F transition is triggered due to a failure in
Offset C RAF D- RN soft handover-based service admission. Only when the signal
6 REQ 02 C quality of the target cell is greater than the sum of the signal
9 HO 02 Soft quality of the best cell plus this parameter value, a D2F transition
1 02 Han can be triggered if soft handover-based service admission fails.
0 dov GUI Value Range: -29~29
er Unit: 0.5dB
Actual Value Range: -14.5~14.5
Default Value: 4
SoftFa B SET W Intr Meaning: Timer during which F2D transitions are forbidden after
ilF2D S UINT RF a a D2F transition is triggered due to a failure in soft handover-
Punish C RAF D- RN based service admission.
Timer 6 REQ 02 C GUI Value Range: 0~512
9 HO 02 Soft Unit: s
0 02 Han
Actual Value Range: 0~512
0 dov
er Default Value: 10
SoftFa B SET W Intr Meaning: Timer during which F2D transitions are forbidden after
ilF2D S UINT RF a a D2F transition is triggered due to a failure in soft handover-
Punish C RAF D- RN based service admission.
Timer 6 REQ 02 C GUI Value Range: 0~512
9 HO 02 Soft Unit: s
1 02 Han
Actual Value Range: 0~512
0 dov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er Default Value: 10
SoftFa B SET W Intr Meaning: Whether to allow for channel switching from the E-
ilE2D S UINT RF a DCH to the DCH (E2D for short) after an HSUPA UE
Switc C RAF D- RN experiences a soft handover failure. If this parameter is set to
h 6 REQ 02 C ON, E2D is allowed when a soft handover fails due to uplink
9 HO 02 Soft admission failures. Otherwise, E2D is not allowed when a soft
0 02 Han handover fails.
0 dov GUI Value Range: OFF, ON
er Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
SoftFa B SET W Intr Meaning: Whether to allow for channel switching from the E-
ilE2D S UINT RF a DCH to the DCH (E2D for short) after an HSUPA UE
Switc C RAF D- RN experiences a soft handover failure. If this parameter is set to
h 6 REQ 02 C ON, E2D is allowed when a soft handover fails due to uplink
9 HO 02 Soft admission failures. Otherwise, E2D is not allowed when a soft
1 02 Han handover fails.
0 dov GUI Value Range: OFF, ON
er Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
D- Loa and Ec/N0 of the active set. In this way, the RNC can decide
01 d whether to perform an inter-RAT handover based on the Ec/N0
06 Bas of the active set. When this switch is turned off, the RNC sends
12 ed only the periodic inter-RAT measurement control to UEs
04 PS processing CS services and the Ec/N0 of the active set is not
W Han considered in the inter-RAT handovers. 7.
RF dov HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH:
D- er Whether the RNC sends the periodic inter-RAT measurement
02 fro control and periodic intra-frequency measurement control
01 m simultaneously to UEs processing PS services. When this switch
29 UM is turned on, the RNC sends the periodic inter-RAT measurement
W TS control and periodic intra-frequency measurement control
RF to simultaneously to UEs processing PS services. The inter-RAT
D- LTE measurement control carries the periodic intra-frequency
14 Ma measurement ID so that the UEs report both the inter-RAT MRs
02 cro and Ec/N0 of the active set. In this way, the RNC can decide
18 & whether to perform an inter-RAT handover based on the Ec/N0
Mic of the active set. When this switch is turned off, the RNC sends
W
ro only the periodic inter-RAT measurement control to UEs
RF
Join processing PS services and the Ec/N0 of the active set is not
D-
t considered in the inter-RAT handovers. 8.
02
Inte HO_MC_INTRAFREQ_NCELL_COMBINE_SWITCH:
03
r- Whether to use the algorithm of intra-frequency neighboring cell
05
freq combination. When this switch is turned on, the algorithm of
W intra-frequency neighboring cell combination is used for intra-
uen
RF frequency measurement objects. When this switch is turned off,
cy
D- the best cell algorithm is used. 9.
Han
02 HO_MC_INTERFREQ_NCELL_COMBINE_SWITCH:
dov
03 Whether to use the algorithm of inter-frequency neighboring cell
er
06 combination. When this switch is turned on, the algorithm of
Cov
erag inter-frequency neighboring cell combination is used for inter-
e frequency measurement objects. When this switch is turned off,
Bas the best cell algorithm is used. 10.
ed HO_MC_GSM_NCELL_COMBINE_SWITCH: Whether to use
PS the algorithm of neighboring GSM cell combination. When this
Han switch is turned on, the algorithm of neighboring GSM cell
dov combination is used for GSM measurement objects. When this
er switch is turned off, the best cell algorithm is used. 11.
fro HO_MC_LTE_NCELL_COMBINE_SWITCH: Whether to use
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Unit: None
Actual Value Range:
HO_COMACROMICRO_INTER_FREQ_OUT_SWITCH,
HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_SWITCH,
HO_U2L_COV_PS_REDIRECT_SWITCH,
HO_U2L_COV_PS_HO_SWITCH,
HO_INTER_RAT_PENALTY_FOR_UNCFG_SWITCH,
HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_MC_INTRAFREQ_NCELL_COMBINE_SWITCH,
HO_MC_INTERFREQ_NCELL_COMBINE_SWITCH,
HO_MC_GSM_NCELL_COMBINE_SWITCH,
HO_MC_LTE_NCELL_COMBINE_SWITCH,
HO_U2L_LOAD_PS_HO_SWITCH,
HO_U2L_LOAD_PS_REDIRECT_SWITCH,
HO_INTRA_FREQ_DETSET_INTO_ACTSET_OPTSWH,
HO_INTRA_DETSET_DRNC_CELL_INTO_ACTSET,
HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWITCH,
HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWITCH,
HO_SPID_MM_SWITCH,
HO_SRV_CELL_CHG_1D_RSCP_SWITCH,
HO_IUR_U2L_REDIR_SWITCH,
HO_IUR_U2L_FAST_RETURN_SWITCH,
HO_LTE_SERVICE_NEED_RSCP_SWITCH,
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_SWITCH,
HO_INTER_RAT_DRNC_GSMNCELL_FILTER_SWITCH
Default Value:
HO_COMACROMICRO_INTER_FREQ_OUT_SWITCH:0,HO
_U2L_REDIR_BASED_ABSOLUTE_FREQ_SWITCH:0,HO_
U2L_COV_PS_REDIRECT_SWITCH:0,HO_U2L_COV_PS_H
O_SWITCH:0,HO_INTER_RAT_PENALTY_FOR_UNCFG_S
WITCH:0,HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SW
ITCH:0,HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWIT
CH:0,HO_MC_INTRAFREQ_NCELL_COMBINE_SWITCH:1
,HO_MC_INTERFREQ_NCELL_COMBINE_SWITCH:1,HO_
MC_GSM_NCELL_COMBINE_SWITCH:1,HO_MC_LTE_NC
ELL_COMBINE_SWITCH:1,HO_U2L_LOAD_PS_HO_SWIT
CH:0,HO_U2L_LOAD_PS_REDIRECT_SWITCH:0,HO_INTR
A_FREQ_DETSET_INTO_ACTSET_OPTSWH:0,HO_INTRA
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
_DETSET_DRNC_CELL_INTO_ACTSET:0,HO_1A_OR_1C_
TRIG_SERV_CELL_CHG_SWITCH:0,HO_1D_TRIG_SERV_
CELL_CHG_JUDGE_SWITCH:0,HO_SPID_MM_SWITCH:0,
HO_SRV_CELL_CHG_1D_RSCP_SWITCH:0,HO_IUR_U2L_
REDIR_SWITCH:1,HO_IUR_U2L_FAST_RETURN_SWITCH
:0,HO_LTE_SERVICE_NEED_RSCP_SWITCH:0,HO_GSMN
CELL_OPGRP_CARRY_OVER_IUR_SWITCH:0,HO_INTER
_RAT_DRNC_GSMNCELL_FILTER_SWITCH:0
to is found to be the only target cell, the RNC does not include
LTE information about this cell in the active set. 16.
Inte HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWITCH:Whethe
r- r to trigger an HSPA serving cell change after a soft handover
RA initiated due to the reporting of event 1A or 1C is complete.
T When this switch is turned on, an HSPA serving cell change is
Han triggered after a soft handover initiated due to the reporting of
dov event 1A or 1C is complete. When this switch is turned off, an
er HSPA serving cell change is not triggered after a soft handover
Bas initiated due to the reporting of event 1A or 1C is complete. 17.
ed HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWITCH:Whethe
on r to trigger an HSPA serving cell change upon the false reporting
Ser of event 1D. The false reporting of event 1D indicates that there
vice is another cell whose signal quality is better than the signal
Inte quality of the best cell indicated in event 1D. When this switch is
r- turned on, an HSPA serving cell change is triggered upon the
RA false reporting of event 1D. When this switch is turned off, an
T HSPA serving cell change is not triggered upon the false
Han reporting of event 1D. 18. HO_SPID_MM_SWITCH: Whether
dov the RNC performs mobility management based on the SPID. 19.
er HO_SRV_CELL_CHG_1D_RSCP_SWITCH: Whether to
Bas trigger a serving cell change upon the reporting of RSCP-based
ed event 1D. When this switch is turned on, a serving cell change is
on triggered upon the reporting of RSCP-based event 1D. When this
Loa switch is turned off, a serving cell change is triggered upon the
d reporting of Ec/No-based event 1D. 20.
HO_IUR_U2L_REDIR_SWITCH: Whether the RNC can
initiate an inter-RNC UMTS-to-LTE redirection. When this
switch is turned on, the RNC can initiate an inter-RNC UMTS-
to-LTE redirection. When this switch is turned off, the RNC
cannot initiate an inter-RNC UMTS-to-LTE redirection. 21.
HO_IUR_U2L_FAST_RETURN_SWITCH: Whether to allow
UMTS-to-LTE Fast Return if the best cell for a UE is controlled
by the DRNC. When this switch is turned on. In this case,
UMTS-to-LTE Fast Return is allowed and the SRNC adds
neighboring LTE cell EARFCNs of the best cell to the RRC
Connection Release message. When this switch is turned off. In
this case, UMTS-to-LTE Fast Return is forbidden. This switch is
effective only when the
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_SWITCH,
HO_U2L_COV_PS_REDIRECT_SWITCH,
HO_U2L_COV_PS_HO_SWITCH,
HO_INTER_RAT_PENALTY_FOR_UNCFG_SWITCH,
HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_MC_INTRAFREQ_NCELL_COMBINE_SWITCH,
HO_MC_INTERFREQ_NCELL_COMBINE_SWITCH,
HO_MC_GSM_NCELL_COMBINE_SWITCH,
HO_MC_LTE_NCELL_COMBINE_SWITCH,
HO_U2L_LOAD_PS_HO_SWITCH,
HO_U2L_LOAD_PS_REDIRECT_SWITCH,
HO_INTRA_FREQ_DETSET_INTO_ACTSET_OPTSWH,
HO_INTRA_DETSET_DRNC_CELL_INTO_ACTSET,
HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWITCH,
HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWITCH,
HO_SPID_MM_SWITCH,
HO_SRV_CELL_CHG_1D_RSCP_SWITCH,
HO_IUR_U2L_REDIR_SWITCH,
HO_IUR_U2L_FAST_RETURN_SWITCH,
HO_LTE_SERVICE_NEED_RSCP_SWITCH,
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_SWITCH,
HO_INTER_RAT_DRNC_GSMNCELL_FILTER_SWITCH
Unit: None
Actual Value Range:
HO_COMACROMICRO_INTER_FREQ_OUT_SWITCH,
HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_SWITCH,
HO_U2L_COV_PS_REDIRECT_SWITCH,
HO_U2L_COV_PS_HO_SWITCH,
HO_INTER_RAT_PENALTY_FOR_UNCFG_SWITCH,
HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_MC_INTRAFREQ_NCELL_COMBINE_SWITCH,
HO_MC_INTERFREQ_NCELL_COMBINE_SWITCH,
HO_MC_GSM_NCELL_COMBINE_SWITCH,
HO_MC_LTE_NCELL_COMBINE_SWITCH,
HO_U2L_LOAD_PS_HO_SWITCH,
HO_U2L_LOAD_PS_REDIRECT_SWITCH,
HO_INTRA_FREQ_DETSET_INTO_ACTSET_OPTSWH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
HO_INTRA_DETSET_DRNC_CELL_INTO_ACTSET,
HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWITCH,
HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWITCH,
HO_SPID_MM_SWITCH,
HO_SRV_CELL_CHG_1D_RSCP_SWITCH,
HO_IUR_U2L_REDIR_SWITCH,
HO_IUR_U2L_FAST_RETURN_SWITCH,
HO_LTE_SERVICE_NEED_RSCP_SWITCH,
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_SWITCH,
HO_INTER_RAT_DRNC_GSMNCELL_FILTER_SWITCH
Default Value:
HO_COMACROMICRO_INTER_FREQ_OUT_SWITCH:0,HO
_U2L_REDIR_BASED_ABSOLUTE_FREQ_SWITCH:0,HO_
U2L_COV_PS_REDIRECT_SWITCH:0,HO_U2L_COV_PS_H
O_SWITCH:0,HO_INTER_RAT_PENALTY_FOR_UNCFG_S
WITCH:0,HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SW
ITCH:0,HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWIT
CH:0,HO_MC_INTRAFREQ_NCELL_COMBINE_SWITCH:1
,HO_MC_INTERFREQ_NCELL_COMBINE_SWITCH:1,HO_
MC_GSM_NCELL_COMBINE_SWITCH:1,HO_MC_LTE_NC
ELL_COMBINE_SWITCH:1,HO_U2L_LOAD_PS_HO_SWIT
CH:0,HO_U2L_LOAD_PS_REDIRECT_SWITCH:0,HO_INTR
A_FREQ_DETSET_INTO_ACTSET_OPTSWH:0,HO_INTRA
_DETSET_DRNC_CELL_INTO_ACTSET:0,HO_1A_OR_1C_
TRIG_SERV_CELL_CHG_SWITCH:0,HO_1D_TRIG_SERV_
CELL_CHG_JUDGE_SWITCH:0,HO_SPID_MM_SWITCH:0,
HO_SRV_CELL_CHG_1D_RSCP_SWITCH:0,HO_IUR_U2L_
REDIR_SWITCH:1,HO_IUR_U2L_FAST_RETURN_SWITCH
:0,HO_LTE_SERVICE_NEED_RSCP_SWITCH:0,HO_GSMN
CELL_OPGRP_CARRY_OVER_IUR_SWITCH:0,HO_INTER
_RAT_DRNC_GSMNCELL_FILTER_SWITCH:0
n Unit: None
Pac Actual Value Range: HO_ALGO_HCS_SPEED_EST_SWITCH,
kag HO_ALGO_LDR_ALLOW_SHO_SWITCH,
e HO_ALGO_MBMS_FLC_SWITCH,
MB HO_ALGO_OVERLAY_SWITCH,
MS HO_INTER_FREQ_HARD_HO_SWITCH,
Intr HO_LTE_SERVICE_PSHO_OUT_SWITCH,
odu HO_INTER_RAT_CS_OUT_SWITCH,
ctio HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH,
n HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH,
Pac HO_INTER_RAT_PS_OUT_SWITCH,
kag HO_INTER_RAT_RNC_SERVICE_HO_SWITCH,
e HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH,
Intr HO_INTRA_FREQ_DETSET_RPRT_SWITCH,
a HO_INTRA_FREQ_HARD_HO_SWITCH,
Fre HO_INTRA_FREQ_RPRT_1J_SWITCH,
que HO_INTRA_FREQ_SOFT_HO_SWITCH,
ncy HO_MC_MEAS_BEYOND_UE_CAP_SWITCH,
Har HO_MC_NCELL_COMBINE_SWITCH,
d HO_MC_SIGNAL_IUR_INTRA_SWITCH,
Han HO_MC_SIGNAL_SWITCH,
dov HO_MC_SNA_RESTRICTION_SWITCH,
er HO_LTE_PS_OUT_SWITCH,
Inte HO_LTE_SERVICE_PS_OUT_SWITCH,
r HO_H2G_SRVCC_SWITCH,
Fre HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWITCH,
que HO_CIO_1D_USED, HO_HCS_SPD_INI_BSD_UE_SWITCH,
ncy HO_L2U_EMGCALL_SWITCH,
Har HO_UMTS_TO_LTE_FAST_RETURN_SWITCH,
d HO_HHO_WITH_INTRA_FREQ_MR_SWITCH,
Han HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH
dov Default Value:
er HO_ALGO_HCS_SPEED_EST_SWITCH:0,HO_ALGO_LDR_
Bas ALLOW_SHO_SWITCH:1,HO_ALGO_MBMS_FLC_SWITC
ed H:0,HO_ALGO_OVERLAY_SWITCH:0,HO_INTER_FREQ_
on HARD_HO_SWITCH:0,HO_LTE_SERVICE_PSHO_OUT_SW
Cov ITCH:0,HO_INTER_RAT_CS_OUT_SWITCH:1,HO_INTER_
erag RAT_PS_3G2G_CELLCHG_NACC_SWITCH:0,HO_INTER_
e RAT_PS_3G2G_RELOCATION_SWITCH:0,HO_INTER_RAT
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Inte _PS_OUT_SWITCH:1,HO_INTER_RAT_RNC_SERVICE_HO
r- _SWITCH:0,HO_INTRA_FREQ_DETSET_INTO_ACTSET_S
RA WITCH:1,HO_INTRA_FREQ_DETSET_RPRT_SWITCH:1,H
T O_INTRA_FREQ_HARD_HO_SWITCH:1,HO_INTRA_FREQ
Han _RPRT_1J_SWITCH:0,HO_INTRA_FREQ_SOFT_HO_SWIT
dov CH:1,HO_MC_MEAS_BEYOND_UE_CAP_SWITCH:0,HO_
er MC_NCELL_COMBINE_SWITCH:1,HO_MC_SIGNAL_IUR_
Bas INTRA_SWITCH:0,HO_MC_SIGNAL_SWITCH:0,HO_MC_S
ed NA_RESTRICTION_SWITCH:0,HO_LTE_PS_OUT_SWITCH
on :0,HO_LTE_SERVICE_PS_OUT_SWITCH:0,HO_H2G_SRVC
Cov C_SWITCH:0,HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWIT
erag CH:0,HO_CIO_1D_USED:0,HO_HCS_SPD_INI_BSD_UE_S
e WITCH:0,HO_L2U_EMGCALL_SWITCH:0,HO_UMTS_TO_
PS LTE_FAST_RETURN_SWITCH:0,HO_HHO_WITH_INTRA_
Han FREQ_MR_SWITCH:0,HO_MULTIRAB_CSPS_HO_COV_PA
dov RA_SWITCH:0
er
Bet
wee
n
UM
TS
and
GP
RS
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RA
T
Han
dov
er
Bas
ed
on
Loa
d
NA
CC(
Net
wor
k
Ass
iste
d
Cell
Cha
nge
)
02 nag network and present network, also gives special handling for
02 eme mobility management of network verge. 5.
03 nt HO_INTER_FREQ_HARD_HO_SWITCH: When the switch is
W Inte on, the RNC is allowed to initiate inter-frequency measure
RF r control or the load-based inter-frequency hard handover upon the
D- RN handover decision on inter-frequency load. 6.
02 C HO_LTE_SERVICE_PSHO_OUT_SWITCH: Whether to enable
02 Soft service-based PS handover from UMTS to LTE. When this
02 Han switch is turned on, the RNC can send LTE MEASUREMENT
W dov CONTROL message based on service and initiate service-based
RF er PS handover from UMTS to LTE. When this switch is turned off,
D- Intr the RNC cannot initiate service-based PS handover from UMTS
02 a to LTE. 7. HO_INTER_RAT_CS_OUT_SWITCH: When the
03 RN switch is on, the RNC is allowed to initiate inter-frequency
09 C measure control and the CS inter-RAT hard handover from the
Soft 3G network to the 2G network. 8.
W
Han HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH:
RF
dov When the switch is on, the NACC function is supported during
D-
er the PS inter-RAT handover from the 3G network to the 2G
02
network in the cell change order process. When the switch is not
01 Inte
on, the NACC function is not supported. When
03 r-
HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH is ON,
W RA
this switch is useless. When the NACC function is supported, the
RF T
UE skips the reading procedure as the SI/PSI of the target cell is
D- Han
provided after the UE accesses the 2G cell. Thus, the delay of
02 dov
inter-cell handover is reduced. 9.
01 er
HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH: When
06 Bas
the switch is on, the PS inter-RAT handover from the 3G
W ed
network to the 2G network is performed in the relocation
RF on
process. When the switch is not on, the PS inter-RAT handover
D- DL
from the 3G network to the 2G network is performed in the cell
01 Qo
change order process. 10.
06 S
HO_INTER_RAT_PS_OUT_SWITCH: When the switch is on,
12 Inte the RNC is allowed to initiate inter-frequency measure control
04 r and the PS inter-RAT hard handover from the 3G network to the
W Fre 2G network. 11.
RF que HO_INTER_RAT_RNC_SERVICE_HO_SWITCH: When the
D- ncy switch is on, the attributes of inter-RAT handover of the services
02 Loa are based on the configuration of RNC parameters. When the
d
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
01 Bal switch is not on, the attributes are set on the basis of the CN. If
29 anc no information is provided by the CN, the attributes are then
W e based on the RNC parameters. 12.
RF Loa HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH:
D- d When the switch is on, the cells in the detected set from which
07 Res the RNC receives their valid event reports can be added to the
00 huff active set. The cells allowed to be added to the active set must be
06 ling the neighboring cells of the cells in the active set. 13.
W HS HO_INTRA_FREQ_DETSET_RPRT_SWITCH: When the
RF UP switch is on, the intra-frequency measurement reports of the
D- A detected set can be reported by UE. 14.
07 Mo HO_INTRA_FREQ_HARD_HO_SWITCH: When the switch is
00 bilit on, the RNC is allowed to initiate the intra-frequency hard
07 y handover. 15. HO_INTRA_FREQ_RPRT_1J_SWITCH: When
Ma the switch is on, the event 1J is included in the delivery of intra-
W
nag frequency measurement control if the UE version is R6 or later
RF
eme versions. 16. HO_INTRA_FREQ_SOFT_HO_SWITCH: When
D-
nt this switch is turned on, the cells under the RNC support soft
14
handovers. Upon receiving event 1A, 1B, 1C, or 1D after
01 PS
delivering an intra-frequency measurement control message to
02 Ser
the UE, the RNC initiates associated addition, removal, and
W vice
replacement of target cell of the soft handover. 17.
RF Red
HO_MC_MEAS_BEYOND_UE_CAP_SWITCH: When the
D- irec
switch is on, the neighboring cell whose frequency band is
07 tion
beyond the UE's capabilities can also be delivered in the inter-
00 fro
frequency measurement list. 18.
05 m
HO_MC_NCELL_COMBINE_SWITCH: When the switch is
W UM
on, the neighboring cell combined algorithm is used during the
RF TS
delivery of the objects to be measured. When the switch is not
D- to
on, the optimal cell algorithm is used. 19.
15 LTE
HO_MC_SIGNAL_IUR_INTRA_SWITCH: When the switch is
02 GS on, intra-frequency handover is allowed over the Iur interface if
01 M the UE has only signaling. 20. HO_MC_SIGNAL_SWITCH:
W and When the switch is on, quality measurement on the active set is
RF UM delivered after signaling setup but before service setup. If the UE
D- TS is at the cell verge or receives weak signals after accessing the
02 Loa network, the RNC can trigger inter-frequency or inter-RAT
13 d handover when the UE sets up the RRC. 21.
11 Bal HO_MC_SNA_RESTRICTION_SWITCH: When the switch is
anci
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
02 ng on, the RNC controls the UEs in the connected state based on the
W Bas configurations on the CN. The UEs can only access and move in
RF ed authorized cells. 22. HO_LTE_PS_OUT_SWITCH: Whether to
D- on enable handover from UMTS to LTE. When this switch is turned
02 Iur- on, the RNC can send LTE MEASUREMENT CONTROL
03 g message and initiate PS handover or redirection from UMTS to
04 GS LTE. When this switch is turned off, the RNC cannot perform the
W M preceding procedures. 23.
RF and HO_LTE_SERVICE_PS_OUT_SWITCH: Whether to enable
D- UM service-based redirection from UMTS to LTE. When this switch
02 TS is turned on, the RNC can send LTE MEASUREMENT
12 Traf CONTROL message based on service and initiate service-based
00 fic PS redirection from UMTS to LTE. When this switch is turned
Stee off, the RNC cannot initiate service-based PS redirection from
W
ring UMTS to LTE. 24. HO_H2G_SRVCC_SWITCH :This bit is a
RF
Bas Single Radio Voice Call Continuity (SRVCC) switch for the
D-
ed VoIP service that is handed over to GERAN. SRVCC ensures the
02
on continuity of voice services that are handed over between the CS
03
Iur- domain and the IP Multimedia Subsystem (IMS).The meaning of
08
g the bit is as follows: When it is set to "ON", it indicates that the
W VoIP service can be handed over to GERAN through SRVCC
RF CS
Fall procedure.When it is set to "OFF", it indicates that the VoIP
D- service cannot be handed over to GERAN through SRVCC
01 bac
k procedure. 25.
06 HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWITCH: This
10 Gua
rant switch controls which event to be preferentially processed when
W both an intra- frequency measurement report event and event 2D
ee
RF or 2F need to be processed. Turning on this switch allows the
for
D- intra-frequency measurement report event to be preferentially
LTE
01 processed. Turning off this switch allows event 2D or 2F to be
Em
06 preferentially processed. 26. HO_CIO_1D_USED: Whether the
erge
12 RNC instructs the UE to use the cell individual offset (CIO)
ncy
W Call parameter when reporting event 1D. If this field is selected, the
RF s RNC instructs the UE to use the CIO parameter when reporting
D- event 1D. If this field is not selected, the RNC does not instruct
NA
01 the UE to use the CIO parameter when reporting event 1D. The
CC
06 call drop rate will increase if the switch is opened when the CIO
Pro
16 is configured to a big value. 27.
ced
W HO_HCS_SPD_INI_BSD_UE_SWITCH: Whether the RNC
ure
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Pac HO_MC_SIGNAL_SWITCH,
kag HO_MC_SNA_RESTRICTION_SWITCH,
e HO_LTE_PS_OUT_SWITCH,
HS HO_LTE_SERVICE_PS_OUT_SWITCH,
UP HO_H2G_SRVCC_SWITCH,
A HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWITCH,
Intr HO_CIO_1D_USED, HO_HCS_SPD_INI_BSD_UE_SWITCH,
odu HO_L2U_EMGCALL_SWITCH,
ctio HO_UMTS_TO_LTE_FAST_RETURN_SWITCH,
n HO_HHO_WITH_INTRA_FREQ_MR_SWITCH,
Pac HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH
kag Unit: None
e Actual Value Range: HO_ALGO_HCS_SPEED_EST_SWITCH,
MB HO_ALGO_LDR_ALLOW_SHO_SWITCH,
MS HO_ALGO_MBMS_FLC_SWITCH,
Intr HO_ALGO_OVERLAY_SWITCH,
odu HO_INTER_FREQ_HARD_HO_SWITCH,
ctio HO_LTE_SERVICE_PSHO_OUT_SWITCH,
n HO_INTER_RAT_CS_OUT_SWITCH,
Pac HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH,
kag HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH,
e HO_INTER_RAT_PS_OUT_SWITCH,
Intr HO_INTER_RAT_RNC_SERVICE_HO_SWITCH,
a HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH,
Fre HO_INTRA_FREQ_DETSET_RPRT_SWITCH,
que HO_INTRA_FREQ_HARD_HO_SWITCH,
ncy HO_INTRA_FREQ_RPRT_1J_SWITCH,
Har HO_INTRA_FREQ_SOFT_HO_SWITCH,
d HO_MC_MEAS_BEYOND_UE_CAP_SWITCH,
Han HO_MC_NCELL_COMBINE_SWITCH,
dov HO_MC_SIGNAL_IUR_INTRA_SWITCH,
er HO_MC_SIGNAL_SWITCH,
Inte HO_MC_SNA_RESTRICTION_SWITCH,
r HO_LTE_PS_OUT_SWITCH,
Fre HO_LTE_SERVICE_PS_OUT_SWITCH,
que HO_H2G_SRVCC_SWITCH,
ncy HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWITCH,
Har HO_CIO_1D_USED, HO_HCS_SPD_INI_BSD_UE_SWITCH,
d HO_L2U_EMGCALL_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Han HO_UMTS_TO_LTE_FAST_RETURN_SWITCH,
dov HO_HHO_WITH_INTRA_FREQ_MR_SWITCH,
er HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH
Bas Default Value:
ed HO_ALGO_HCS_SPEED_EST_SWITCH:0,HO_ALGO_LDR_
on ALLOW_SHO_SWITCH:1,HO_ALGO_MBMS_FLC_SWITC
Cov H:0,HO_ALGO_OVERLAY_SWITCH:0,HO_INTER_FREQ_
erag HARD_HO_SWITCH:0,HO_LTE_SERVICE_PSHO_OUT_SW
e ITCH:0,HO_INTER_RAT_CS_OUT_SWITCH:1,HO_INTER_
Inte RAT_PS_3G2G_CELLCHG_NACC_SWITCH:0,HO_INTER_
r- RAT_PS_3G2G_RELOCATION_SWITCH:0,HO_INTER_RAT
RA _PS_OUT_SWITCH:1,HO_INTER_RAT_RNC_SERVICE_HO
T _SWITCH:0,HO_INTRA_FREQ_DETSET_INTO_ACTSET_S
Han WITCH:1,HO_INTRA_FREQ_DETSET_RPRT_SWITCH:1,H
dov O_INTRA_FREQ_HARD_HO_SWITCH:1,HO_INTRA_FREQ
er _RPRT_1J_SWITCH:0,HO_INTRA_FREQ_SOFT_HO_SWIT
Bas CH:1,HO_MC_MEAS_BEYOND_UE_CAP_SWITCH:0,HO_
ed MC_NCELL_COMBINE_SWITCH:1,HO_MC_SIGNAL_IUR_
on INTRA_SWITCH:0,HO_MC_SIGNAL_SWITCH:0,HO_MC_S
Cov NA_RESTRICTION_SWITCH:0,HO_LTE_PS_OUT_SWITCH
erag :0,HO_LTE_SERVICE_PS_OUT_SWITCH:0,HO_H2G_SRVC
e C_SWITCH:0,HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWIT
PS CH:0,HO_CIO_1D_USED:0,HO_HCS_SPD_INI_BSD_UE_S
Han WITCH:0,HO_L2U_EMGCALL_SWITCH:0,HO_UMTS_TO_
dov LTE_FAST_RETURN_SWITCH:0,HO_HHO_WITH_INTRA_
er FREQ_MR_SWITCH:0,HO_MULTIRAB_CSPS_HO_COV_PA
Bet RA_SWITCH:0
wee
n
UM
TS
and
GP
RS
Inte
r-
RA
T
Han
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
NA
CC(
Net
wor
k
Ass
iste
d
Cell
Cha
nge
)
Reser B SET W Dyn Meaning: CORRM algorithm reserved switch 0. The switch is
vedSw S UCO RF ami reserved for further change request use. Disuse statement: This
itch0 C RRM D- c parameter is used temporarily in patch versions and will be
6 ALG 02 Cha replaced with a new parameter in later versions. The new
9 OSWI 11 nnel parameter ID reflects the parameter function. Therefore, this
0 TCH 01 Con parameter is not recommended for the configuration interface.
0 W figu GUI Value Range: RESERVED_SWITCH_0_BIT1,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF rati RESERVED_SWITCH_0_BIT2,
D- on RESERVED_SWITCH_0_BIT3,
02 Con RESERVED_SWITCH_0_BIT4,
02 trol RESERVED_SWITCH_0_BIT5,
03 (DC RESERVED_SWITCH_0_BIT6,
W CC) RESERVED_SWITCH_0_BIT7,
RF Inte RESERVED_SWITCH_0_BIT8,
D- r RESERVED_SWITCH_0_BIT9,
02 RN RESERVED_SWITCH_0_BIT10,
04 C RESERVED_SWITCH_0_BIT11,
00 Soft RESERVED_SWITCH_0_BIT12,
01 Han RESERVED_SWITCH_0_BIT13,
W dov RESERVED_SWITCH_0_BIT14,
RF er RESERVED_SWITCH_0_BIT15,
D- Intr RESERVED_SWITCH_0_BIT16,
01 a RESERVED_SWITCH_0_BIT17,
06 Syst RESERVED_SWITCH_0_BIT18,
13 em RESERVED_SWITCH_0_BIT19,
Dir RESERVED_SWITCH_0_BIT20,
W
ect RESERVED_SWITCH_0_BIT21,
RF
Retr RESERVED_SWITCH_0_BIT22,
D-
y RESERVED_SWITCH_0_BIT23,
02
RESERVED_SWITCH_0_BIT24,
14 AM
RESERVED_SWITCH_0_BIT25,
00 R-
RESERVED_SWITCH_0_BIT26,
W WB
RESERVED_SWITCH_0_BIT27,
RF (Ad
RESERVED_SWITCH_0_BIT28,
D- apti
RESERVED_SWITCH_0_BIT29,
02 ve
RESERVED_SWITCH_0_BIT30,
07 Mul
RESERVED_SWITCH_0_BIT31,
01 ti
RESERVED_SWITCH_0_BIT32
Rat
e Unit: None
Wid Actual Value Range: RESERVED_SWITCH_0_BIT1,
e RESERVED_SWITCH_0_BIT2,
Ban RESERVED_SWITCH_0_BIT3,
d) RESERVED_SWITCH_0_BIT4,
Dir RESERVED_SWITCH_0_BIT5,
ect RESERVED_SWITCH_0_BIT6,
Sig RESERVED_SWITCH_0_BIT7,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
nali RESERVED_SWITCH_0_BIT8,
ng RESERVED_SWITCH_0_BIT9,
Con RESERVED_SWITCH_0_BIT10,
nect RESERVED_SWITCH_0_BIT11,
ion RESERVED_SWITCH_0_BIT12,
Re- RESERVED_SWITCH_0_BIT13,
esta RESERVED_SWITCH_0_BIT14,
blis RESERVED_SWITCH_0_BIT15,
hme RESERVED_SWITCH_0_BIT16,
nt RESERVED_SWITCH_0_BIT17,
(DS RESERVED_SWITCH_0_BIT18,
CR) RESERVED_SWITCH_0_BIT19,
AM RESERVED_SWITCH_0_BIT20,
R/ RESERVED_SWITCH_0_BIT21,
WB RESERVED_SWITCH_0_BIT22,
- RESERVED_SWITCH_0_BIT23,
AM RESERVED_SWITCH_0_BIT24,
R RESERVED_SWITCH_0_BIT25,
Spe RESERVED_SWITCH_0_BIT26,
ech RESERVED_SWITCH_0_BIT27,
Rat RESERVED_SWITCH_0_BIT28,
es RESERVED_SWITCH_0_BIT29,
Con RESERVED_SWITCH_0_BIT30,
trol RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Default Value: RESERVED_SWITCH_0_BIT1:0,
RESERVED_SWITCH_0_BIT2:0,
RESERVED_SWITCH_0_BIT3:0,
RESERVED_SWITCH_0_BIT4:0,
RESERVED_SWITCH_0_BIT5:0,
RESERVED_SWITCH_0_BIT6:0,
RESERVED_SWITCH_0_BIT7:0,
RESERVED_SWITCH_0_BIT8:0,
RESERVED_SWITCH_0_BIT9:0,
RESERVED_SWITCH_0_BIT10:0,
RESERVED_SWITCH_0_BIT11:0,
RESERVED_SWITCH_0_BIT12:0,
RESERVED_SWITCH_0_BIT13:0,
RESERVED_SWITCH_0_BIT14:0,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT15:0,
RESERVED_SWITCH_0_BIT16:0,
RESERVED_SWITCH_0_BIT17:0,
RESERVED_SWITCH_0_BIT18:0,
RESERVED_SWITCH_0_BIT19:0,
RESERVED_SWITCH_0_BIT20:0,
RESERVED_SWITCH_0_BIT21:0,
RESERVED_SWITCH_0_BIT22:0,
RESERVED_SWITCH_0_BIT23:0,
RESERVED_SWITCH_0_BIT24:0,
RESERVED_SWITCH_0_BIT25:0,
RESERVED_SWITCH_0_BIT26:0,
RESERVED_SWITCH_0_BIT27:0,
RESERVED_SWITCH_0_BIT28:0,
RESERVED_SWITCH_0_BIT29:0,
RESERVED_SWITCH_0_BIT30:0,
RESERVED_SWITCH_0_BIT31:0,
RESERVED_SWITCH_0_BIT32:0
Reser B SET W Dyn Meaning: CORRM algorithm reserved switch 0. The switch is
vedSw S UCO RF ami reserved for further change request use. Disuse statement: This
itch0 C RRM D- c parameter is used temporarily in patch versions and will be
6 ALG 02 Cha replaced with a new parameter in later versions. The new
9 OSWI 11 nnel parameter ID reflects the parameter function. Therefore, this
1 TCH 01 Con parameter is not recommended for the configuration interface.
0 W figu GUI Value Range: RESERVED_SWITCH_0_BIT1,
RF rati RESERVED_SWITCH_0_BIT2,
D- on RESERVED_SWITCH_0_BIT3,
02 Con RESERVED_SWITCH_0_BIT4,
02 trol RESERVED_SWITCH_0_BIT5,
03 (DC RESERVED_SWITCH_0_BIT6,
W CC) RESERVED_SWITCH_0_BIT7,
RF Inte RESERVED_SWITCH_0_BIT8,
D- r RESERVED_SWITCH_0_BIT9,
02 RN RESERVED_SWITCH_0_BIT10,
04 C RESERVED_SWITCH_0_BIT11,
00 Soft RESERVED_SWITCH_0_BIT12,
01 Han RESERVED_SWITCH_0_BIT13,
W dov RESERVED_SWITCH_0_BIT14,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF er RESERVED_SWITCH_0_BIT15,
D- Intr RESERVED_SWITCH_0_BIT16,
01 a RESERVED_SWITCH_0_BIT17,
06 Syst RESERVED_SWITCH_0_BIT18,
13 em RESERVED_SWITCH_0_BIT19,
W Dir RESERVED_SWITCH_0_BIT20,
RF ect RESERVED_SWITCH_0_BIT21,
D- Retr RESERVED_SWITCH_0_BIT22,
02 y RESERVED_SWITCH_0_BIT23,
14 AM RESERVED_SWITCH_0_BIT24,
00 R- RESERVED_SWITCH_0_BIT25,
W WB RESERVED_SWITCH_0_BIT26,
RF (Ad RESERVED_SWITCH_0_BIT27,
D- apti RESERVED_SWITCH_0_BIT28,
02 ve RESERVED_SWITCH_0_BIT29,
07 Mul RESERVED_SWITCH_0_BIT30,
01 ti RESERVED_SWITCH_0_BIT31,
Rat RESERVED_SWITCH_0_BIT32
e Unit: None
Wid Actual Value Range: RESERVED_SWITCH_0_BIT1,
e RESERVED_SWITCH_0_BIT2,
Ban RESERVED_SWITCH_0_BIT3,
d) RESERVED_SWITCH_0_BIT4,
Dir RESERVED_SWITCH_0_BIT5,
ect RESERVED_SWITCH_0_BIT6,
Sig RESERVED_SWITCH_0_BIT7,
nali RESERVED_SWITCH_0_BIT8,
ng RESERVED_SWITCH_0_BIT9,
Con RESERVED_SWITCH_0_BIT10,
nect RESERVED_SWITCH_0_BIT11,
ion RESERVED_SWITCH_0_BIT12,
Re- RESERVED_SWITCH_0_BIT13,
esta RESERVED_SWITCH_0_BIT14,
blis RESERVED_SWITCH_0_BIT15,
hme RESERVED_SWITCH_0_BIT16,
nt RESERVED_SWITCH_0_BIT17,
(DS RESERVED_SWITCH_0_BIT18,
CR) RESERVED_SWITCH_0_BIT19,
AM RESERVED_SWITCH_0_BIT20,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
R/ RESERVED_SWITCH_0_BIT21,
WB RESERVED_SWITCH_0_BIT22,
- RESERVED_SWITCH_0_BIT23,
AM RESERVED_SWITCH_0_BIT24,
R RESERVED_SWITCH_0_BIT25,
Spe RESERVED_SWITCH_0_BIT26,
ech RESERVED_SWITCH_0_BIT27,
Rat RESERVED_SWITCH_0_BIT28,
es RESERVED_SWITCH_0_BIT29,
Con RESERVED_SWITCH_0_BIT30,
trol RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Default Value: RESERVED_SWITCH_0_BIT1:0,
RESERVED_SWITCH_0_BIT2:0,
RESERVED_SWITCH_0_BIT3:0,
RESERVED_SWITCH_0_BIT4:0,
RESERVED_SWITCH_0_BIT5:0,
RESERVED_SWITCH_0_BIT6:0,
RESERVED_SWITCH_0_BIT7:0,
RESERVED_SWITCH_0_BIT8:0,
RESERVED_SWITCH_0_BIT9:0,
RESERVED_SWITCH_0_BIT10:0,
RESERVED_SWITCH_0_BIT11:0,
RESERVED_SWITCH_0_BIT12:0,
RESERVED_SWITCH_0_BIT13:0,
RESERVED_SWITCH_0_BIT14:0,
RESERVED_SWITCH_0_BIT15:0,
RESERVED_SWITCH_0_BIT16:0,
RESERVED_SWITCH_0_BIT17:0,
RESERVED_SWITCH_0_BIT18:0,
RESERVED_SWITCH_0_BIT19:0,
RESERVED_SWITCH_0_BIT20:0,
RESERVED_SWITCH_0_BIT21:0,
RESERVED_SWITCH_0_BIT22:0,
RESERVED_SWITCH_0_BIT23:0,
RESERVED_SWITCH_0_BIT24:0,
RESERVED_SWITCH_0_BIT25:0,
RESERVED_SWITCH_0_BIT26:0,
RESERVED_SWITCH_0_BIT27:0,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT28:0,
RESERVED_SWITCH_0_BIT29:0,
RESERVED_SWITCH_0_BIT30:0,
RESERVED_SWITCH_0_BIT31:0,
RESERVED_SWITCH_0_BIT32:0
Ban the reconfigured uplink rate must be smaller than or equal to the
d reconfigured downlink rate. When this switch is set to on, the
Net RNC does not consider the cell congestion state and the
wor maximum bit rates (MBRs) are used for uplink and downlink
kin admission during an AMR service setup. During RB
g reconfigurations for WB-AMR services, the RNC uses the same
Ma rate mode for the uplink and downlink. 18.
nag CMP_DL_LOAD_BALANCE_SWITCH: Whether the RNC
eme filters out the neighboring cells for blind handovers based on the
nt downlink load margin when inter-frequency DRD for load
balancing takes effect in the downlink during a blind-handover-
based non-periodic DRD. When this switch is turned off, a
neighboring cell for blind handovers cannot serve as the target
neighboring cell for inter-frequency blind handovers if the
difference between the downlink load margins of the
neighboring cell and the current cell is less than the value of the
"LdbDRDOffsetDCH" or "LdbDRDOffsetHSDPA" parameter.
When this switch is turned on, the RNC does not filter out any
neighboring cell for blind handovers. 19.
CMP_AMR_A_SUBFLOW_ZERO_BLOCK_SWITCH: Uplink
0 kbit/s transport format of AMR service subflow A, expressed
in TbNum * TbSize. When this switch is turned off, the format is
1*0. When this switch is turned on, the format is 0*TbSize. 20.
CMP_IUR_MULTI_RL_ADD_RETRY_SWITCH: Whether to
enable the compatibility algorithm when multiple RLs are added
to the same DRNC. When this switch is turned off, the RNC
stops attempting to re-establish the RL if an RL fails to be added
with the failure cause of "RadioNetwork:unspecified (14)".
When this switch is turned on, the RNC attempts to re-establish
the RL only once if an RL fails to be added with the failure cause
of "RadioNetwork:unspecified (14)". 21.
CMP_MBDR_CALL_TYPE_OTHER_AS_AMR_SWITCH:
Whether a conversational service of a UE complying with 3GPP
Release 6 and later are allowed for inter-RAT measurement-
based directed retry (MBDR) if CallType of the conversational
service is Other. 22.
CMP_SRNSR_WAMR_MODE_0_RESTORE_SWITCH:
Whether the 0 kbit/s transport format is added on the Iu interface
during an incoming static relocation of a WB-AMR speech
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CMP_RAB_DRD_ROLLBACK_PUNISH_SWITCH,
CMP_WBAMR_SUBFLOW_SWITCH,
CMP_IUR_CELLCAP_BITMAP_TRANSFORM_SWITCH,
CMP_MOCN_PLMN_SEL_SWITCH,
CMP_LOSSLESS_RELOC_RLCPDUSIZECHG_SWITCH,
CMP_CS_FIXED_RATE_WHEN_PS_EXIST_SWITCH,
CMP_SRB_H_AMR_DRD_HHO_SWITCH,
CMP_UU_AMR_DRD_HHO_COMPAT_ENH_SWITCH,
CMP_SINGLE_PTT_USE_DL_ENL2_SWITCH,
CMP_F2D_RLC_ONESIDE_REBUILD_SWITCH,
CMP_DRD_SRBOVERH_SWITCH,
CMP_AMRC_FIXED_INITRATE_SWITCH,
CMP_DL_LOAD_BALANCE_SWITCH,
CMP_AMR_A_SUBFLOW_ZERO_BLOCK_SWITCH,
CMP_IUR_MULTI_RL_ADD_RETRY_SWITCH,
CMP_MBDR_CALL_TYPE_OTHER_AS_AMR_SWITCH,
CMP_SRNSR_WAMR_MODE_0_RESTORE_SWITCH,
CMP_GSM_NCELL_BAND_1900M_SWITCH,
CMP_ACTIVESET_REPORT_WITH_SYN_SWITCH,
CMP_READSFN_IND_IN_SIB_SWITCH,
CMP_UE_NOT_USE_DL_ENL2_EXIST_PTT_SWITCH,
CMP_RELOC_IN_FACH_DEL_DCH_SWITCH,
CMP_CELL_UPDATE_FACH_TRFFIC_MC_OPT,
CMP_MR_AGPS_MC_MSG_SEND_OPT_SWITCH
Unit: None
Actual Value Range:
CMP_RELOCIN_IUUPVER_NOTCHG_SWITCH,
CMP_IUBR_DM_RTT_ALTERNATIVE_FMT_SWITCH,
CMP_IUR_CMCF_SWITCH,
CMP_STTD_RL_ADD_SWITCH,
CMP_STTD_ASU_SWITCH,
CMP_RAB_DRD_ROLLBACK_PUNISH_SWITCH,
CMP_WBAMR_SUBFLOW_SWITCH,
CMP_IUR_CELLCAP_BITMAP_TRANSFORM_SWITCH,
CMP_MOCN_PLMN_SEL_SWITCH,
CMP_LOSSLESS_RELOC_RLCPDUSIZECHG_SWITCH,
CMP_CS_FIXED_RATE_WHEN_PS_EXIST_SWITCH,
CMP_SRB_H_AMR_DRD_HHO_SWITCH,
CMP_UU_AMR_DRD_HHO_COMPAT_ENH_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CMP_SINGLE_PTT_USE_DL_ENL2_SWITCH,
CMP_F2D_RLC_ONESIDE_REBUILD_SWITCH,
CMP_DRD_SRBOVERH_SWITCH,
CMP_AMRC_FIXED_INITRATE_SWITCH,
CMP_DL_LOAD_BALANCE_SWITCH,
CMP_AMR_A_SUBFLOW_ZERO_BLOCK_SWITCH,
CMP_IUR_MULTI_RL_ADD_RETRY_SWITCH,
CMP_MBDR_CALL_TYPE_OTHER_AS_AMR_SWITCH,
CMP_SRNSR_WAMR_MODE_0_RESTORE_SWITCH,
CMP_GSM_NCELL_BAND_1900M_SWITCH,
CMP_ACTIVESET_REPORT_WITH_SYN_SWITCH,
CMP_READSFN_IND_IN_SIB_SWITCH,
CMP_UE_NOT_USE_DL_ENL2_EXIST_PTT_SWITCH,
CMP_RELOC_IN_FACH_DEL_DCH_SWITCH,
CMP_CELL_UPDATE_FACH_TRFFIC_MC_OPT,
CMP_MR_AGPS_MC_MSG_SEND_OPT_SWITCH
Default Value:
CMP_RELOCIN_IUUPVER_NOTCHG_SWITCH:0,CMP_IUB
R_DM_RTT_ALTERNATIVE_FMT_SWITCH:0,CMP_IUR_C
MCF_SWITCH:0,CMP_STTD_RL_ADD_SWITCH:0,CMP_ST
TD_ASU_SWITCH:0,CMP_RAB_DRD_ROLLBACK_PUNIS
H_SWITCH:0,CMP_WBAMR_SUBFLOW_SWITCH:0,CMP_I
UR_CELLCAP_BITMAP_TRANSFORM_SWITCH:0,CMP_M
OCN_PLMN_SEL_SWITCH:0,CMP_LOSSLESS_RELOC_RL
CPDUSIZECHG_SWITCH:0,CMP_CS_FIXED_RATE_WHEN
_PS_EXIST_SWITCH:0,CMP_SRB_H_AMR_DRD_HHO_SW
ITCH:0,CMP_UU_AMR_DRD_HHO_COMPAT_ENH_SWITC
H:0,CMP_SINGLE_PTT_USE_DL_ENL2_SWITCH:0,CMP_F
2D_RLC_ONESIDE_REBUILD_SWITCH:0,CMP_DRD_SRB
OVERH_SWITCH:0,CMP_AMRC_FIXED_INITRATE_SWIT
CH:0,CMP_DL_LOAD_BALANCE_SWITCH:0,CMP_AMR_
A_SUBFLOW_ZERO_BLOCK_SWITCH:0,CMP_IUR_MULT
I_RL_ADD_RETRY_SWITCH:0,CMP_MBDR_CALL_TYPE_
OTHER_AS_AMR_SWITCH:0,CMP_SRNSR_WAMR_MODE
_0_RESTORE_SWITCH:0,CMP_GSM_NCELL_BAND_1900
M_SWITCH:0,CMP_ACTIVESET_REPORT_WITH_SYN_S
WITCH:1,CMP_READSFN_IND_IN_SIB_SWITCH:1,CMP_U
E_NOT_USE_DL_ENL2_EXIST_PTT_SWITCH:0,CMP_REL
OC_IN_FACH_DEL_DCH_SWITCH:0,CMP_CELL_UPDATE
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
_FACH_TRFFIC_MC_OPT:0,CMP_MR_AGPS_MC_MSG_SE
ND_OPT_SWITCH:1
W Spe failed directed retry after best cell changed. By default, this
RF cifi switch is set to OFF. 7. CMP_WBAMR_SUBFLOW_SWITCH:
D- cati When the switch is set to ON, the number of WB AMR service
02 ons substreams is configured according to the number of substreams
01 3C- specified in the RAB ASSIGNMENT REQUEST message.
34 HS When the switch is set to OFF, the number of WB AMR service
W DP substreams is 3. This switch is introduced to comply with the
RF A Change Request (CR) specified in the related protocol, that is,
D- Pus three substreams need to be established for a WB AMR service.
01 h to The switch CMP_WBAMR_SUBFLOW_SWITCH in this
05 Talk version supports configuration synchronization and delivery, but
01 the RNC does not use this switch any longer. Future versions do
Con
W not support this switch. Therefore, it is recommended that users
vers
RF avoid using this switch. 8.
atio
D- CMP_IUR_CELLCAP_BITMAP_TRANSFORM_SWITCH:
nal
02 The switch is used to solve the problem that different vendors'
Qo
06 RNCs interpret the cell capability bitmap differently on the Iur
S
05 interface. When the switch is set to ON, the RNC interprets the
Cla
01 cell capability bitmap in a sequence opposite to that specified by
ss
the related protocol. When the switch is set to OFF, the RNC
W SR interprets the cell capability bitmap in the sequence specified by
RF NS the related protocol. 9. CMP_MOCN_PLMN_SEL_SWITCH:
D- Rel When the switch is set to ON, if the UE supports the MOCN
01 ocat feature, the SRNC preferentially uses the PLMN of the UE's
02 ion homing operator in the RELOCATION REQUIRED message,
02 (UE and the TRNC preferentially uses the PLMN of the UE's homing
W Not operator in the LOCATION REPORT message and the DIRECT
RF Inv TRANSFER message during relocation; if the UE does not
D- olve support the MOCN feature, the SRNC and the TRNC
15 d) preferentially use the common operator's PLMN in these above
02 UE messages. When the switch is set to OFF, the SRNC
09 Stat preferentially uses the PLMN of the UE's homing operator in the
W e in RELOCATION REQUIRED message, and the TRNC
RF Con preferentially uses the PLMN of the UE's homing operator in the
D- nect LOCATION REPORT message, but the TRNC preferentially
02 ed uses the common operator's PLMN in the DIRECT TRANSFER
04 Mo message during relocation. 10.
02 de CMP_LOSSLESS_RELOC_RLCPDUSIZECHG_SWITCH:
W (CE When the switch is set to ON, the RNC sets the "Support for
LL-
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
wor maximum bit rates (MBRs) are used for uplink and downlink
kin admission during an AMR service setup. During RB
g reconfigurations for WB-AMR services, the RNC uses the same
Ma rate mode for the uplink and downlink. 18.
nag CMP_DL_LOAD_BALANCE_SWITCH: Whether the RNC
eme filters out the neighboring cells for blind handovers based on the
nt downlink load margin when inter-frequency DRD for load
balancing takes effect in the downlink during a blind-handover-
based non-periodic DRD. When this switch is turned off, a
neighboring cell for blind handovers cannot serve as the target
neighboring cell for inter-frequency blind handovers if the
difference between the downlink load margins of the
neighboring cell and the current cell is less than the value of the
"LdbDRDOffsetDCH" or "LdbDRDOffsetHSDPA" parameter.
When this switch is turned on, the RNC does not filter out any
neighboring cell for blind handovers. 19.
CMP_AMR_A_SUBFLOW_ZERO_BLOCK_SWITCH: Uplink
0 kbit/s transport format of AMR service subflow A, expressed
in TbNum * TbSize. When this switch is turned off, the format is
1*0. When this switch is turned on, the format is 0*TbSize. 20.
CMP_IUR_MULTI_RL_ADD_RETRY_SWITCH: Whether to
enable the compatibility algorithm when multiple RLs are added
to the same DRNC. When this switch is turned off, the RNC
stops attempting to re-establish the RL if an RL fails to be added
with the failure cause of "RadioNetwork:unspecified (14)".
When this switch is turned on, the RNC attempts to re-establish
the RL only once if an RL fails to be added with the failure cause
of "RadioNetwork:unspecified (14)". 21.
CMP_MBDR_CALL_TYPE_OTHER_AS_AMR_SWITCH:
Whether a conversational service of a UE complying with 3GPP
Release 6 and later are allowed for inter-RAT measurement-
based directed retry (MBDR) if CallType of the conversational
service is Other. 22.
CMP_SRNSR_WAMR_MODE_0_RESTORE_SWITCH:
Whether the 0 kbit/s transport format is added on the Iu interface
during an incoming static relocation of a WB-AMR speech
service. When this switch is turned off, the 0 kbit/s transport
format is added on the Iu interface if the Uu interface has the 0
kbit/s transport format. When this switch is turned on, the 0
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CMP_MOCN_PLMN_SEL_SWITCH,
CMP_LOSSLESS_RELOC_RLCPDUSIZECHG_SWITCH,
CMP_CS_FIXED_RATE_WHEN_PS_EXIST_SWITCH,
CMP_SRB_H_AMR_DRD_HHO_SWITCH,
CMP_UU_AMR_DRD_HHO_COMPAT_ENH_SWITCH,
CMP_SINGLE_PTT_USE_DL_ENL2_SWITCH,
CMP_F2D_RLC_ONESIDE_REBUILD_SWITCH,
CMP_DRD_SRBOVERH_SWITCH,
CMP_AMRC_FIXED_INITRATE_SWITCH,
CMP_DL_LOAD_BALANCE_SWITCH,
CMP_AMR_A_SUBFLOW_ZERO_BLOCK_SWITCH,
CMP_IUR_MULTI_RL_ADD_RETRY_SWITCH,
CMP_MBDR_CALL_TYPE_OTHER_AS_AMR_SWITCH,
CMP_SRNSR_WAMR_MODE_0_RESTORE_SWITCH,
CMP_GSM_NCELL_BAND_1900M_SWITCH,
CMP_ACTIVESET_REPORT_WITH_SYN_SWITCH,
CMP_READSFN_IND_IN_SIB_SWITCH,
CMP_UE_NOT_USE_DL_ENL2_EXIST_PTT_SWITCH,
CMP_RELOC_IN_FACH_DEL_DCH_SWITCH,
CMP_CELL_UPDATE_FACH_TRFFIC_MC_OPT,
CMP_MR_AGPS_MC_MSG_SEND_OPT_SWITCH
Unit: None
Actual Value Range:
CMP_RELOCIN_IUUPVER_NOTCHG_SWITCH,
CMP_IUBR_DM_RTT_ALTERNATIVE_FMT_SWITCH,
CMP_IUR_CMCF_SWITCH,
CMP_STTD_RL_ADD_SWITCH,
CMP_STTD_ASU_SWITCH,
CMP_RAB_DRD_ROLLBACK_PUNISH_SWITCH,
CMP_WBAMR_SUBFLOW_SWITCH,
CMP_IUR_CELLCAP_BITMAP_TRANSFORM_SWITCH,
CMP_MOCN_PLMN_SEL_SWITCH,
CMP_LOSSLESS_RELOC_RLCPDUSIZECHG_SWITCH,
CMP_CS_FIXED_RATE_WHEN_PS_EXIST_SWITCH,
CMP_SRB_H_AMR_DRD_HHO_SWITCH,
CMP_UU_AMR_DRD_HHO_COMPAT_ENH_SWITCH,
CMP_SINGLE_PTT_USE_DL_ENL2_SWITCH,
CMP_F2D_RLC_ONESIDE_REBUILD_SWITCH,
CMP_DRD_SRBOVERH_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CMP_AMRC_FIXED_INITRATE_SWITCH,
CMP_DL_LOAD_BALANCE_SWITCH,
CMP_AMR_A_SUBFLOW_ZERO_BLOCK_SWITCH,
CMP_IUR_MULTI_RL_ADD_RETRY_SWITCH,
CMP_MBDR_CALL_TYPE_OTHER_AS_AMR_SWITCH,
CMP_SRNSR_WAMR_MODE_0_RESTORE_SWITCH,
CMP_GSM_NCELL_BAND_1900M_SWITCH,
CMP_ACTIVESET_REPORT_WITH_SYN_SWITCH,
CMP_READSFN_IND_IN_SIB_SWITCH,
CMP_UE_NOT_USE_DL_ENL2_EXIST_PTT_SWITCH,
CMP_RELOC_IN_FACH_DEL_DCH_SWITCH,
CMP_CELL_UPDATE_FACH_TRFFIC_MC_OPT,
CMP_MR_AGPS_MC_MSG_SEND_OPT_SWITCH
Default Value:
CMP_RELOCIN_IUUPVER_NOTCHG_SWITCH:0,CMP_IUB
R_DM_RTT_ALTERNATIVE_FMT_SWITCH:0,CMP_IUR_C
MCF_SWITCH:0,CMP_STTD_RL_ADD_SWITCH:0,CMP_ST
TD_ASU_SWITCH:0,CMP_RAB_DRD_ROLLBACK_PUNIS
H_SWITCH:0,CMP_WBAMR_SUBFLOW_SWITCH:0,CMP_I
UR_CELLCAP_BITMAP_TRANSFORM_SWITCH:0,CMP_M
OCN_PLMN_SEL_SWITCH:0,CMP_LOSSLESS_RELOC_RL
CPDUSIZECHG_SWITCH:0,CMP_CS_FIXED_RATE_WHEN
_PS_EXIST_SWITCH:0,CMP_SRB_H_AMR_DRD_HHO_SW
ITCH:0,CMP_UU_AMR_DRD_HHO_COMPAT_ENH_SWITC
H:0,CMP_SINGLE_PTT_USE_DL_ENL2_SWITCH:0,CMP_F
2D_RLC_ONESIDE_REBUILD_SWITCH:0,CMP_DRD_SRB
OVERH_SWITCH:0,CMP_AMRC_FIXED_INITRATE_SWIT
CH:0,CMP_DL_LOAD_BALANCE_SWITCH:0,CMP_AMR_
A_SUBFLOW_ZERO_BLOCK_SWITCH:0,CMP_IUR_MULT
I_RL_ADD_RETRY_SWITCH:0,CMP_MBDR_CALL_TYPE_
OTHER_AS_AMR_SWITCH:0,CMP_SRNSR_WAMR_MODE
_0_RESTORE_SWITCH:0,CMP_GSM_NCELL_BAND_1900
M_SWITCH:0,CMP_ACTIVESET_REPORT_WITH_SYN_S
WITCH:1,CMP_READSFN_IND_IN_SIB_SWITCH:1,CMP_U
E_NOT_USE_DL_ENL2_EXIST_PTT_SWITCH:0,CMP_REL
OC_IN_FACH_DEL_DCH_SWITCH:0,CMP_CELL_UPDATE
_FACH_TRFFIC_MC_OPT:0,CMP_MR_AGPS_MC_MSG_SE
ND_OPT_SWITCH:1
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
_BIT3:0,RSVDBIT1_BIT4:0,RSVDBIT1_BIT5:0,RSVDBIT1_
BIT6:0,RSVDBIT1_BIT7:0,RSVDBIT1_BIT8:0,RSVDBIT1_B
IT9:0,RSVDBIT1_BIT10:0,RSVDBIT1_BIT11:0,RSVDBIT1_
BIT12:0,RSVDBIT1_BIT13:0,RSVDBIT1_BIT14:0,RSVDBIT
1_BIT15:0,RSVDBIT1_BIT16:0,SYSHO_CSIN_PERMIT_SWI
TCH:1,RSVDBIT1_BIT18:1,RSVDBIT1_BIT19:1,RSVDBIT1_
BIT20:1,RSVDBIT1_BIT21:1,RSVDBIT1_BIT22:1,RSVDBIT
1_BIT23:1,RSVDBIT1_BIT24:1,RSVDBIT1_BIT25:1,RSVDBI
T1_BIT26:1,RSVDBIT1_BIT27:1,RSVDBIT1_BIT28:1,RSVD
BIT1_BIT29:1,RSVDBIT1_BIT30:1,RSVDBIT1_BIT31:1,RSV
DBIT1_BIT32:1
considered as successful.
19)COUNT_STATE_CHG_BY_RAB_EHN_SWITCH Whether
to enable certain state transition-related counters to be
incremented on a PS RAB basis. These counters include the
VS.DCCC.P2D.Att, VS.DCCC.P2D.Succ, VS.DCCC.Att.D2U,
and VS.DCCC.Succ.D2U counters. 1: This switch is turned on.
These counters are incremented on a PS RAB basis. 0: This
switch is turned off. These counters are incremented on a UE
basis. 20)RAB_RELATED_COUNTER_OPT_SWITCH(RAB
Setup Failure Statistical Optimization Switch) Whether to
optimize the statistics of counters measuring RAB setup failures
and abnormal RAB releases. 1: This switch is turned on. Under
this circumstance, the statistics of counters measuring RAB
setup failures and abnormal RAB releases are optimized. 0: This
switch is turned off. Under this circumstance, the statistics of
counters measuring RAB setup failures and abnormal RAB
releases are not optimized.
21)CELLUPDATE_PROCEDURE_OPT_SWITCH (Cell
Update Procedure Optimization Switch) Whether to enable the
optimized processing for the cell update procedure. 1: This
switch is set to on. The RNC supports the overlapping of these
two procedures: cell update procedure caused by RL failure and
P2D/D2P/D2F state transition procedure. For UEs in the
CELL_DCH state, the RNC performs a cell update procedure
based on the retransmitted CELL UPDATE message if the
retransmitted message carries an SRB or TRB reset indication.
For UEs in the CELL_PCH or URA_PCH state, when the
number of CELL UPDATE messages with the cause value
paging response or UL data transmission exceeds the value
specified by N381, the RNC sends an RRC connection release
message to the UE in the cell where the UE sends the last CELL
UPDATE message. For UEs in states other than CELL_DCH or
in the middle of state transitions other than P2D, if the SRNC
receives a CELL UPDATE message with HRNTI from a UE
through the DRNC while waiting for the UE's response to the
CELL UPDATE CONFIRM message, the SRNC considers the
message as a retransmitted one. 0. This switch is set to off. The
optimized processing for the cell update procedure is not
supported. 22)PTT_PAGING_PRD_CRRCT_SWITCH(Correct
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CM_CODE_CONFLICT_OPT_SWITCH(CM_CODE_CONFLI
CT_OPT_SWITCH),
H_SERV_CELL_CHANGE_MSG_OPT_SWITCH(H_SERV_C
ELL_CHANGE_MSG_OPT_SWITCH),
FAST_HSDPA_SERV_CELL_CHANGE_SWITCH(FAST_HS
DPA_SERV_CELL_CHANGE_SWITCH),
RLRST_ASU_SUCC_COUNTERS_CORRECT_SWITCH(RL
RST_ASU_SUCC_COUNTERS_CORRECT_SWITCH),
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH(COUNT_S
TATE_CHG_BY_RAB_EHN_SWITCH),
RAB_RELATED_COUNTER_OPT_SWITCH(RAB_RELATE
D_COUNTER_OPT_SWITCH),
CELLUPDATE_PROCEDURE_OPT_SWITCH(CELLUPDATE
_PROCEDURE_OPT_SWITCH),
PTT_PAGING_PRD_CRRCT_SWITCH(PTT_PAGING_PRD_
CRRCT_SWITCH),
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITCH(RRC_R
EL_STATUS_RSP_RAB_ASS_REQ_SWITCH),
L2U_UP_DELAY_OPT_SWITCH(L2U_UP_DELAY_OPT_S
WITCH),
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH(PRI_
LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH)
Unit: None
Actual Value Range:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH,
RL_REEST_PS_ON_FACH_SWITCH,
CELLUPDATE_MEASUREMENT_OPT_SWITCH,
D2F_PROCEDURE_OPTIMIZATION_SWITCH,
F2D_PROCEDURE_OPTIMIZATION_SWITCH,
FOREVER_PCH_CTRL_PLANE_SHARE_OPT,
FOREVER_PCH_USER_PLANE_SHARE_OPT,
RAB_REL_SRV_CELL_CHG_CROSS_SWITCH,
SCRIWITHCAUSE_OVERLAP_SWITCH,
P2F_CUC_REPEAT_SWITCH,
UU_ABN_REL_INFO_NOTIFY_NODEB_SWITCH,
D2F_AM_PROCEDURE_OPTIMIZATION_SWITCH,
AM_D2F_F2D_RESTMR_OPTIMIZATION_SWITCH,
D2P_DT_MSG_BUFFER_SWITCH,
CM_CODE_CONFLICT_OPT_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
H_SERV_CELL_CHANGE_MSG_OPT_SWITCH,
FAST_HSDPA_SERV_CELL_CHANGE_SWITCH,
RLRST_ASU_SUCC_COUNTERS_CORRECT_SWITCH,
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH,
RAB_RELATED_COUNTER_OPT_SWITCH,
CELLUPDATE_PROCEDURE_OPT_SWITCH,
PTT_PAGING_PRD_CRRCT_SWITCH,
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITCH,
L2U_UP_DELAY_OPT_SWITCH,
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH
Default Value:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH:1,RL_REES
T_PS_ON_FACH_SWITCH:0,CELLUPDATE_MEASUREME
NT_OPT_SWITCH:0,D2F_PROCEDURE_OPTIMIZATION_S
WITCH:0,F2D_PROCEDURE_OPTIMIZATION_SWITCH:0,F
OREVER_PCH_CTRL_PLANE_SHARE_OPT:0,FOREVER_P
CH_USER_PLANE_SHARE_OPT:0,RAB_REL_SRV_CELL_
CHG_CROSS_SWITCH:0,SCRIWITHCAUSE_OVERLAP_S
WITCH:0,P2F_CUC_REPEAT_SWITCH:0,UU_ABN_REL_IN
FO_NOTIFY_NODEB_SWITCH:0,D2F_AM_PROCEDURE_
OPTIMIZATION_SWITCH:0,AM_D2F_F2D_RESTMR_OPTI
MIZATION_SWITCH:0,D2P_DT_MSG_BUFFER_SWITCH:0,
CM_CODE_CONFLICT_OPT_SWITCH:1,H_SERV_CELL_C
HANGE_MSG_OPT_SWITCH:0,FAST_HSDPA_SERV_CELL
_CHANGE_SWITCH:0,RLRST_ASU_SUCC_COUNTERS_C
ORRECT_SWITCH:0,COUNT_STATE_CHG_BY_RAB_EHN
_SWITCH:0,RAB_RELATED_COUNTER_OPT_SWITCH:0,C
ELLUPDATE_PROCEDURE_OPT_SWITCH:1,PTT_PAGING
_PRD_CRRCT_SWITCH:0,RRC_REL_STATUS_RSP_RAB_A
SS_REQ_SWITCH:0,L2U_UP_DELAY_OPT_SWITCH:1,PRI
_LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH:0
to wait for a response message from the UE after the RNC sends
a RADIO BEARER RECONFIGURATION message to the UE
in AM during the D2F and F2D state transitions. 1: This switch
is turned on. The length of the timer equals its configured value
(value of the "RbRecfgRspTmr" parameter in the "SET
USTATETIMER" command) plus four seconds. 0: This switch is
turned off. The length of this timer equals its configured value.
14)D2P_DT_MSG_BUFFER_SWITCH (DT Message Buffer
Switch During D2P) Whether the RNC buffers the DIRECT
TRANSFER message sent by the CN during the D2P state
transition. 1: This switch is turned on. The RNC buffers the
DIRECT TRANSFER message. The RNC sends a paging
message to the UE after the D2P state transition is complete and
then sends the buffered DIRECT TRANSFER message to the
UE. 0: This switch is turned off. The RNC forwards the DIRECT
TRANSFER message to the UE immediately after receiving it.
15)CM_CODE_CONFLICT_OPT_SWITCH Used to solve code
resource conflicts in compressed mode. 1: This switch is turned
on. Code resource conflicts in compressed mode are solved. 0:
This switch is turned off. Code resource conflicts in compressed
mode are not solved.
16)H_SERV_CELL_CHANGE_MSG_OPT_SWITCH(Enable H
Serving Cell Change MSG Size Reduction) Whether to reduce
the size of the HSDPA serving cell change message. 1: This
switch is turned on. The size of the HSDPA serving cell change
message is reduced. 0: This switch is turned off. The size of the
HSDPA serving cell change message is not reduced.
17)FAST_HSDPA_SERV_CELL_CHANGE_SWITCH (Fast
HSDPA Serving Cell Change Optimization Switch) Whether to
enable the fast HSDPA serving cell change optimization
function. 1: This switch is turned on. The RNC includes the IE
Delay restriction flag in the PHYSICAL CHANNEL
RECONFIGURATION message. For details about the IE Delay
restriction flag, see section 10.2.22 in 3GPP TS25.331. 0: This
switch is turned off. The RNC does not include the IE Delay
restriction flag in the PHYSICAL CHANNEL
RECONFIGURATION message.
18)RLRST_ASU_SUCC_COUNTERS_CORRECT_SWITCH(S
HO Counting Correction Switch in RL Reestablish) When the
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UU_ABN_REL_INFO_NOTIFY_NODEB_SWITCH(UU_ABN
_REL_INFO_NOTIFY_NODEB_SWITCH),
D2F_AM_PROCEDURE_OPTIMIZATION_SWITCH(D2F_A
M_PROCEDURE_OPTIMIZATION_SWITCH),
AM_D2F_F2D_RESTMR_OPTIMIZATION_SWITCH(AM_D
2F_F2D_RESTMR_OPTIMIZATION_SWITCH),
D2P_DT_MSG_BUFFER_SWITCH(D2P_DT_MSG_BUFFER
_SWITCH),
CM_CODE_CONFLICT_OPT_SWITCH(CM_CODE_CONFLI
CT_OPT_SWITCH),
H_SERV_CELL_CHANGE_MSG_OPT_SWITCH(H_SERV_C
ELL_CHANGE_MSG_OPT_SWITCH),
FAST_HSDPA_SERV_CELL_CHANGE_SWITCH(FAST_HS
DPA_SERV_CELL_CHANGE_SWITCH),
RLRST_ASU_SUCC_COUNTERS_CORRECT_SWITCH(RL
RST_ASU_SUCC_COUNTERS_CORRECT_SWITCH),
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH(COUNT_S
TATE_CHG_BY_RAB_EHN_SWITCH),
RAB_RELATED_COUNTER_OPT_SWITCH(RAB_RELATE
D_COUNTER_OPT_SWITCH),
CELLUPDATE_PROCEDURE_OPT_SWITCH(CELLUPDATE
_PROCEDURE_OPT_SWITCH),
PTT_PAGING_PRD_CRRCT_SWITCH(PTT_PAGING_PRD_
CRRCT_SWITCH),
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITCH(RRC_R
EL_STATUS_RSP_RAB_ASS_REQ_SWITCH),
L2U_UP_DELAY_OPT_SWITCH(L2U_UP_DELAY_OPT_S
WITCH),
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH(PRI_
LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH)
Unit: None
Actual Value Range:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH,
RL_REEST_PS_ON_FACH_SWITCH,
CELLUPDATE_MEASUREMENT_OPT_SWITCH,
D2F_PROCEDURE_OPTIMIZATION_SWITCH,
F2D_PROCEDURE_OPTIMIZATION_SWITCH,
FOREVER_PCH_CTRL_PLANE_SHARE_OPT,
FOREVER_PCH_USER_PLANE_SHARE_OPT,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RAB_REL_SRV_CELL_CHG_CROSS_SWITCH,
SCRIWITHCAUSE_OVERLAP_SWITCH,
P2F_CUC_REPEAT_SWITCH,
UU_ABN_REL_INFO_NOTIFY_NODEB_SWITCH,
D2F_AM_PROCEDURE_OPTIMIZATION_SWITCH,
AM_D2F_F2D_RESTMR_OPTIMIZATION_SWITCH,
D2P_DT_MSG_BUFFER_SWITCH,
CM_CODE_CONFLICT_OPT_SWITCH,
H_SERV_CELL_CHANGE_MSG_OPT_SWITCH,
FAST_HSDPA_SERV_CELL_CHANGE_SWITCH,
RLRST_ASU_SUCC_COUNTERS_CORRECT_SWITCH,
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH,
RAB_RELATED_COUNTER_OPT_SWITCH,
CELLUPDATE_PROCEDURE_OPT_SWITCH,
PTT_PAGING_PRD_CRRCT_SWITCH,
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITCH,
L2U_UP_DELAY_OPT_SWITCH,
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH
Default Value:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH:1,RL_REES
T_PS_ON_FACH_SWITCH:0,CELLUPDATE_MEASUREME
NT_OPT_SWITCH:0,D2F_PROCEDURE_OPTIMIZATION_S
WITCH:0,F2D_PROCEDURE_OPTIMIZATION_SWITCH:0,F
OREVER_PCH_CTRL_PLANE_SHARE_OPT:0,FOREVER_P
CH_USER_PLANE_SHARE_OPT:0,RAB_REL_SRV_CELL_
CHG_CROSS_SWITCH:0,SCRIWITHCAUSE_OVERLAP_S
WITCH:0,P2F_CUC_REPEAT_SWITCH:0,UU_ABN_REL_IN
FO_NOTIFY_NODEB_SWITCH:0,D2F_AM_PROCEDURE_
OPTIMIZATION_SWITCH:0,AM_D2F_F2D_RESTMR_OPTI
MIZATION_SWITCH:0,D2P_DT_MSG_BUFFER_SWITCH:0,
CM_CODE_CONFLICT_OPT_SWITCH:1,H_SERV_CELL_C
HANGE_MSG_OPT_SWITCH:0,FAST_HSDPA_SERV_CELL
_CHANGE_SWITCH:0,RLRST_ASU_SUCC_COUNTERS_C
ORRECT_SWITCH:0,COUNT_STATE_CHG_BY_RAB_EHN
_SWITCH:0,RAB_RELATED_COUNTER_OPT_SWITCH:0,C
ELLUPDATE_PROCEDURE_OPT_SWITCH:1,PTT_PAGING
_PRD_CRRCT_SWITCH:0,RRC_REL_STATUS_RSP_RAB_A
SS_REQ_SWITCH:0,L2U_UP_DELAY_OPT_SWITCH:1,PRI
_LDR_SYSHO_OUT_USE_SELECT_OPT_SWITCH:0
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
erag
e
d
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
RA
T
Han
dov
er
Bas
ed
on
Loa
d
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
W dov
RF er
D- Bas
02 ed
04 on
02 Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
RrcRs B SET W TTI Meaning: Interval for UEs to report the RSCP during the interval
cpPeri S UCH RF Swi between RRC connection setup and RAB assignment
odTim C LQU D- tch GUI Value Range: D250, D500, D1000, D2000, D3000, D4000,
er 6 ALIT 01 for D6000, D8000, D12000, D16000, D20000, D24000, D28000,
9 YEV 06 BE D32000, D64000
0 ALU 90 Ser Unit: ms
0 ATE vice
Actual Value Range: 250, 500, 1000, 2000, 3000, 4000, 6000,
s
8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000
Bas
ed Default Value: D500
on
Cov
erag
e
RrcRs B SET W TTI Meaning: Interval for UEs to report the RSCP during the interval
cpPeri S UCH RF Swi between RRC connection setup and RAB assignment
odTim C LQU D- tch GUI Value Range: D250, D500, D1000, D2000, D3000, D4000,
er 6 ALIT 01 for D6000, D8000, D12000, D16000, D20000, D24000, D28000,
9 YEV 06 BE D32000, D64000
1 ALU 90 Ser Unit: ms
0 ATE vice
Actual Value Range: 250, 500, 1000, 2000, 3000, 4000, 6000,
s
8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000
Bas
ed Default Value: D500
on
Cov
erag
e
RabRs B SET W TTI Meaning: Interval for UEs to report the RSCP after a service
cpPeri S UCH RF Swi setup.
odTim C LQU D- tch GUI Value Range: D250, D500, D1000, D2000, D3000, D4000,
er 6 ALIT 01 for D6000, D8000, D12000, D16000, D20000, D24000, D28000,
9 YEV 06 BE D32000, D64000
0 ALU 90 Ser Unit: ms
0 ATE vice
Actual Value Range: 250, 500, 1000, 2000, 3000, 4000, 6000,
s
8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000
Bas
Default Value: D2000
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ed
on
Cov
erag
e
RabRs B SET W TTI Meaning: Interval for UEs to report the RSCP after a service
cpPeri S UCH RF Swi setup.
odTim C LQU D- tch GUI Value Range: D250, D500, D1000, D2000, D3000, D4000,
er 6 ALIT 01 for D6000, D8000, D12000, D16000, D20000, D24000, D28000,
9 YEV 06 BE D32000, D64000
1 ALU 90 Ser Unit: ms
0 ATE vice
Actual Value Range: 250, 500, 1000, 2000, 3000, 4000, 6000,
s
8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000
Bas
ed Default Value: D2000
on
Cov
erag
e
Interfr B ADD W Inte Meaning: Whether to measure the signal quality of inter-
eqMc S UCE RF r frequency neighboring cells in batches. When this switch is
Mode C LLIN D- Fre turned on, the RNC instructs UEs to preferentially measure the
6 TERF 02 que signal quality of up to two frequencies with high coverage-based
9 REQ 03 ncy inter-frequency handover priorities. If the measurement expires,
0 HOC 02 Har these UEs stop the measurement on these frequencies and start
0 OV d the measurement on the other frequencies based on their
MOD Han coverage-based inter-frequency handover priorities. The higher
UCE dov the priority of a frequency is, the more likely the signal quality
LLIN er of the frequency is measured. In each batch, up to two
TERF Bas frequencies are involved. When this switch is turned off, the
REQ ed RNC instructs UEs to measure the signal quality of only up to
HOC on two frequencies with high coverage-based inter-frequency
OV Cov handover priorities. A maximum of 32 inter-frequency
erag neighboring cells can be involved in a measurement, regardless
e of whether this switch is turned on or off. For example, there are
five inter-frequency neighboring cells (cells 1 through 5). As for
frequencies, cells 1 and 2 use frequency a, and cells 3 through 5
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Interfr B ADD W Inte Meaning: Whether to measure the signal quality of inter-
eqMc S UCE RF r frequency neighboring cells in batches. When this switch is
Mode C LLIN D- Fre turned on, the RNC instructs UEs to preferentially measure the
6 TERF 02 que signal quality of up to two frequencies with high coverage-based
9 REQ 03 ncy inter-frequency handover priorities. If the measurement expires,
1 HOC 02 Har these UEs stop the measurement on these frequencies and start
0 OV d the measurement on the other frequencies based on their
MOD Han coverage-based inter-frequency handover priorities. The higher
UCE dov the priority of a frequency is, the more likely the signal quality
LLIN er of the frequency is measured. In each batch, up to two
TERF Bas frequencies are involved. When this switch is turned off, the
REQ ed RNC instructs UEs to measure the signal quality of only up to
HOC on two frequencies with high coverage-based inter-frequency
OV Cov handover priorities. A maximum of 32 inter-frequency
erag neighboring cells can be involved in a measurement, regardless
e of whether this switch is turned on or off. For example, there are
five inter-frequency neighboring cells (cells 1 through 5). As for
frequencies, cells 1 and 2 use frequency a, and cells 3 through 5
use frequencies b through d, respectively. As for coverage-based
inter-frequency handover priorities, the priority of cells 1 and 2
is high, that of cell 3 is middle, and that of cells 4 and 5 is low.
When this switch is turned on, a UE preferentially starts a
measurement in cells 1 through 3. If the measurement expires,
the UE starts a measurement in cells 4 and 5. When this switch is
turned off, the UE performs a measurement in only cells 1
through 3.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
InterF B ADD W Inte Meaning: Whether the RNC considers the RTWP of the target
reqHO S UCE RF r cell when performing coverage-based inter-frequency handovers.
Consi C LLIN D- Fre When this switch is set to on, the RNC performs coverage-based
derRT 6 TERF 02 que inter-frequency handovers only when the uplink coverage
WPS 9 REQ 03 ncy (RTWP) of the target cell meets certain conditions. When this
w 0 HOC 02 Har switch is set to off, the RNC does not consider the uplink
0 OV d coverage of the target cell when performing coverage-based
MOD Han inter-frequency handovers.
UCE dov GUI Value Range: OFF, ON
LLIN er Unit: None
TERF Bas
Actual Value Range: ON, OFF
REQ ed
on Default Value: OFF
HOC
OV Cov
erag
e
InterF B ADD W Inte Meaning: Whether the RNC considers the RTWP of the target
reqHO S UCE RF r cell when performing coverage-based inter-frequency handovers.
Consi C LLIN D- Fre When this switch is set to on, the RNC performs coverage-based
derRT 6 TERF 02 que inter-frequency handovers only when the uplink coverage
WPS 9 REQ 03 ncy (RTWP) of the target cell meets certain conditions. When this
w 1 HOC 02 Har switch is set to off, the RNC does not consider the uplink
0 OV d coverage of the target cell when performing coverage-based
MOD Han inter-frequency handovers.
UCE dov GUI Value Range: OFF, ON
LLIN er Unit: None
TERF Bas
Actual Value Range: ON, OFF
REQ ed
on Default Value: OFF
HOC
OV Cov
erag
e
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Unit: None
Actual Value Range:
INTERRAT_LOAD_SINGLE_RPT_FOR_LTE_SWITCH,
INTERRAT_LOAD_REPORT_FROM_LTE_SWITCH,
UL_EVQI_SWITCH, DL_EVQI_SWITCH,
VIDEO_RATE_ADAPTION_SWITCH,
VOIP_MANAGE_SWITCH,
DIFF_SERVICE_ON_TERMINAL_SWITCH,
APP_GRP_RES_RSV_SWITCH, RIM_ON_ECO_SWITCH,
SRBCHG_DRD_FAST_RB_SETUP_SWITCH,
SRBNOCHG_DRD_FAST_RB_SETUP_SWITCH,
FACH_RB_RECFG_FAIL_SPEC_CAUSE_SWITCH,
WBAMR_HHO_FAIL_ROLLBACK_SWITCH
Default Value:
INTERRAT_LOAD_SINGLE_RPT_FOR_LTE_SWITCH:0,IN
TERRAT_LOAD_REPORT_FROM_LTE_SWITCH:0,UL_EVQ
I_SWITCH:0,DL_EVQI_SWITCH:0,VIDEO_RATE_ADAPTI
ON_SWITCH:0,VOIP_MANAGE_SWITCH:0,DIFF_SERVICE
_ON_TERMINAL_SWITCH:0,APP_GRP_RES_RSV_SWITC
H:0,RIM_ON_ECO_SWITCH:0,SRBCHG_DRD_FAST_RB_S
ETUP_SWITCH:0,SRBNOCHG_DRD_FAST_RB_SETUP_SW
ITCH:0,FACH_RB_RECFG_FAIL_SPEC_CAUSE_SWITCH:0
,WBAMR_HHO_FAIL_ROLLBACK_SWITCH:0
09 tiate the load information about LTE cells through the RAN
02 d information management (RIM) procedure. For details about the
11 Ser RIM procedure, see 3GPP TS 48. 018. 1: This switch is turned
W vice on. The RNC obtains the load information about LTE cells
RF Bas through the RIM procedure. 0: This switch is turned off. The
D- ed RNC cannot obtain the load information about LTE cells through
15 on the RIM procedure. 3)UL_EVQI_SWITCH(UL EVQI
02 App Evaluation Switch) Whether to enable the EVQI function in the
54 licat uplink. 1: This switch is turned on. EVQI is enabled in the
W ion uplink. 0: This switch is turned off. EVQI is disabled in the
RF Res uplink. 4)DL_EVQI_SWITCH(DL EVQI Evaluation Switch)
D- our Whether to enable the EVQI function in the downlink. 1: This
15 ce switch is turned on. EVQI is enabled in the downlink. 0: This
02 Res switch is turned off. EVQI is disabled in the downlink. 5)
55 erva VIDEO_RATE_ADAPTION_SWITCH (Video Service Rate
tion Adaption Switch) Whether the Video Service Rate Adaption
Diff feature is enabled. 1: This switch is turned on. The Video Service
eren Rate Adaption feature is enabled for PS UEs processing video
tiate services. That is, the rate of video service is ensured or is limited
d for these PS UEs. 0: This switch is turned off. The Video Service
Ser Rate Adaption feature is disabled for PS UEs. 6)
vice VOIP_MANAGE_SWITCH (VoIP Application Management
Bas Switch) Whether the VoIP application management function is
ed enabled. 1: This switch is turned on. VoIP application
on management actions are performed on PS UEs that are
Ter processing VoIP services. VoIP application management actions
min can either be VoIP application rate ensurance or VoIP application
al speed limit. 0: This switch is turned off. the VoIP application
management function is disabled for PS UEs. 7)
DIFF_SERVICE_ON_TERMINAL_SWITCH (Differentiated
Service Based on Terminal Switch) Whether the Differentiated
Service Based on Terminal feature is enabled. 1: This switch is
turned on. PS UEs processing BE services are grouped into
different terminal groups based on their type approval codes
(TACs) in IMEIs, and each terminal group is assigned an SPI
weight for BE services, thereby achieving differentiated services.
0: This switch is turned off. The Differentiated Service Based on
Terminal feature is disabled for PS UEs processing BE services.
8) APP_GRP_RES_RSV_SWITCH (Differentiated Service
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
This switch is turned off. The RNC does not release the UE's
RRC connection and rolls back the procedure.
13)WBAMR_HHO_FAIL_ROLLBACK_SWITCH Whether
RNC performs rollback operations when AMR-WB services
experience hard handover failures. 1: This switch is turned on.
The RNC performs rollback operations when AMR-WB services
experience hard handover failures. Before setting this switch to
ON, you are advised to run the "SET UCONNMODETIMER"
command to set T312 to 1s. Otherwise, some UEs experience
garbled noise. 0: This switch is turned off. The RNC does not
perform rollback operations when AMR-WB services experience
hard handover failures, and UEs experience call drops.
GUI Value Range:
INTERRAT_LOAD_SINGLE_RPT_FOR_LTE_SWITCH,
INTERRAT_LOAD_REPORT_FROM_LTE_SWITCH,
UL_EVQI_SWITCH, DL_EVQI_SWITCH,
VIDEO_RATE_ADAPTION_SWITCH,
VOIP_MANAGE_SWITCH,
DIFF_SERVICE_ON_TERMINAL_SWITCH,
APP_GRP_RES_RSV_SWITCH, RIM_ON_ECO_SWITCH,
SRBCHG_DRD_FAST_RB_SETUP_SWITCH,
SRBNOCHG_DRD_FAST_RB_SETUP_SWITCH,
FACH_RB_RECFG_FAIL_SPEC_CAUSE_SWITCH,
WBAMR_HHO_FAIL_ROLLBACK_SWITCH
Unit: None
Actual Value Range:
INTERRAT_LOAD_SINGLE_RPT_FOR_LTE_SWITCH,
INTERRAT_LOAD_REPORT_FROM_LTE_SWITCH,
UL_EVQI_SWITCH, DL_EVQI_SWITCH,
VIDEO_RATE_ADAPTION_SWITCH,
VOIP_MANAGE_SWITCH,
DIFF_SERVICE_ON_TERMINAL_SWITCH,
APP_GRP_RES_RSV_SWITCH, RIM_ON_ECO_SWITCH,
SRBCHG_DRD_FAST_RB_SETUP_SWITCH,
SRBNOCHG_DRD_FAST_RB_SETUP_SWITCH,
FACH_RB_RECFG_FAIL_SPEC_CAUSE_SWITCH,
WBAMR_HHO_FAIL_ROLLBACK_SWITCH
Default Value:
INTERRAT_LOAD_SINGLE_RPT_FOR_LTE_SWITCH:0,IN
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TERRAT_LOAD_REPORT_FROM_LTE_SWITCH:0,UL_EVQ
I_SWITCH:0,DL_EVQI_SWITCH:0,VIDEO_RATE_ADAPTI
ON_SWITCH:0,VOIP_MANAGE_SWITCH:0,DIFF_SERVICE
_ON_TERMINAL_SWITCH:0,APP_GRP_RES_RSV_SWITC
H:0,RIM_ON_ECO_SWITCH:0,SRBCHG_DRD_FAST_RB_S
ETUP_SWITCH:0,SRBNOCHG_DRD_FAST_RB_SETUP_SW
ITCH:0,FACH_RB_RECFG_FAIL_SPEC_CAUSE_SWITCH:0
,WBAMR_HHO_FAIL_ROLLBACK_SWITCH:0
DivCt B SET W Intr Meaning: Whether the NodeB implements maximum ratio
rlField S UHO RF a combination. There are two combination methods for uplink
C COM D- Nod combination of soft handover: one is maximum ratio
6 M 02 eB combination on the NodeB side, which gives the highest
9 02 Soft combination gain; the other is selective combination at the RNC,
0 01 er which gives a relatively smaller combination gain. When MAY
0 W Han is selected, the NodeB decides whether to implement maximum
RF dov ratio combination according to its own physical conditions.
D- er When MUST is selected, the NodeB is forced to carry out
02 Inte maximum ratio combination which is usually used in tests. In
02 r this case, if the NodeB does not support maximum ratio
03 RN combination, link setup or adding fails. When MUST_NOT is
W C selected, the NodeB is forbidden to carry out maximum ratio
RF Soft combination. If the NodeB does not implement maximum ratio
D- Han combination, the RNC automatically performs selective
02 dov combination.
02 er GUI Value Range: MAY(NodeB chooses whether combine at
02 Intr NodeB), MUST(Must combine at NodeB), MUST_NOT(Must
a combine at RNC)
RN Unit: None
C Actual Value Range: MAY, MUST, MUST_NOT
Soft Default Value: MAY(NodeB chooses whether combine at
Han NodeB)
dov
er
DivCt B SET W Intr Meaning: Whether the NodeB implements maximum ratio
rlField S UHO RF a combination. There are two combination methods for uplink
C COM D- Nod combination of soft handover: one is maximum ratio
6 M 02 eB combination on the NodeB side, which gives the highest
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CMP_RAB_5_CFG_ROHC_SWITCH,
CMP_RAB_6_CFG_ROHC_SWITCH,
CMP_RAB_7_CFG_ROHC_SWITCH,
CMP_RAB_8_CFG_ROHC_SWITCH,
CMP_RAB_9_CFG_ROHC_SWITCH,
CMP_HSUPA_MACD_FLOW_MUL_SWITCH,
CMP_SMLC_RSLT_MODE_TYPE_SWITCH
Unit: None
Actual Value Range:
CMP_IU_IMS_PROC_AS_NORMAL_PS_SWITCH,
CMP_IU_QOS_ASYMMETRY_IND_COMPAT_SWITCH,
CMP_IU_SYSHOIN_CMP_IUUP_FIXTO1_SWITCH,
CMP_IUR_H2D_FOR_LOWR5_NRNCCELL_SWITCH,
CMP_IUR_SHO_DIVCTRL_SWITCH,
CMP_UU_ADJACENT_FREQ_CM_SWITCH,
CMP_UU_AMR_DRD_HHO_COMPAT_SWITCH,
CMP_UU_AMR_SID_MUST_CFG_SWITCH,
CMP_UU_FDPCH_COMPAT_SWITCH,
CMP_UU_IGNORE_UE_RLC_CAP_SWITCH,
CMP_UU_INTRA_FREQ_MC_BESTCELL_CIO_SWITCH,
CMP_UU_IOS_CELL_SYNC_INFO_REPORT_SWITCH,
CMP_UU_SERV_CELL_CHG_WITH_ASU_SWITCH,
CMP_UU_SERV_CELL_CHG_WITH_RB_MOD_SWITCH,
CMP_UU_VOIP_UP_PROC_AS_NORMAL_PS_SWITCH,
CMP_F2F_RLC_ONESIDE_REBUILD_SWITCH,
CMP_D2F_RLC_ONESIDE_REBUILD_SWITCH,
CMP_RAB_5_CFG_ROHC_SWITCH,
CMP_RAB_6_CFG_ROHC_SWITCH,
CMP_RAB_7_CFG_ROHC_SWITCH,
CMP_RAB_8_CFG_ROHC_SWITCH,
CMP_RAB_9_CFG_ROHC_SWITCH,
CMP_HSUPA_MACD_FLOW_MUL_SWITCH,
CMP_SMLC_RSLT_MODE_TYPE_SWITCH,
CMP_F2P_PROCESS_OPTIMIZATION_SWITCH,
CMP_UU_SIB11_SIB12_WITH_1A1D_SWITCH
Default Value:
CMP_IU_IMS_PROC_AS_NORMAL_PS_SWITCH:0,CMP_I
U_QOS_ASYMMETRY_IND_COMPAT_SWITCH:0,CMP_IU
_SYSHOIN_CMP_IUUP_FIXTO1_SWITCH:0,CMP_IUR_H2
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
D_FOR_LOWR5_NRNCCELL_SWITCH:0,CMP_IUR_SHO_
DIVCTRL_SWITCH:0,CMP_UU_ADJACENT_FREQ_CM_S
WITCH:0,CMP_UU_AMR_DRD_HHO_COMPAT_SWITCH:1
,CMP_UU_AMR_SID_MUST_CFG_SWITCH:0,CMP_UU_FD
PCH_COMPAT_SWITCH:0,CMP_UU_IGNORE_UE_RLC_C
AP_SWITCH:1,CMP_UU_INTRA_FREQ_MC_BESTCELL_C
IO_SWITCH:0,CMP_UU_IOS_CELL_SYNC_INFO_REPORT
_SWITCH:0,CMP_UU_SERV_CELL_CHG_WITH_ASU_SWI
TCH:0,CMP_UU_SERV_CELL_CHG_WITH_RB_MOD_SWI
TCH:1,CMP_UU_VOIP_UP_PROC_AS_NORMAL_PS_SWIT
CH:1,CMP_F2F_RLC_ONESIDE_REBUILD_SWITCH:0,CMP
_D2F_RLC_ONESIDE_REBUILD_SWITCH:0,CMP_RAB_5_
CFG_ROHC_SWITCH:0,CMP_RAB_6_CFG_ROHC_SWITC
H:0,CMP_RAB_7_CFG_ROHC_SWITCH:0,CMP_RAB_8_CF
G_ROHC_SWITCH:0,CMP_RAB_9_CFG_ROHC_SWITCH:0,
CMP_HSUPA_MACD_FLOW_MUL_SWITCH:0,CMP_SMLC
_RSLT_MODE_TYPE_SWITCH:0,CMP_F2P_PROCESS_OPT
IMIZATION_SWITCH:0,CMP_UU_SIB11_SIB12_WITH_1A1
D_SWITCH:0
CMP_RAB_7_CFG_ROHC_SWITCH,
CMP_RAB_8_CFG_ROHC_SWITCH,
CMP_RAB_9_CFG_ROHC_SWITCH,
CMP_HSUPA_MACD_FLOW_MUL_SWITCH,
CMP_SMLC_RSLT_MODE_TYPE_SWITCH
Unit: None
Actual Value Range:
CMP_IU_IMS_PROC_AS_NORMAL_PS_SWITCH,
CMP_IU_QOS_ASYMMETRY_IND_COMPAT_SWITCH,
CMP_IU_SYSHOIN_CMP_IUUP_FIXTO1_SWITCH,
CMP_IUR_H2D_FOR_LOWR5_NRNCCELL_SWITCH,
CMP_IUR_SHO_DIVCTRL_SWITCH,
CMP_UU_ADJACENT_FREQ_CM_SWITCH,
CMP_UU_AMR_DRD_HHO_COMPAT_SWITCH,
CMP_UU_AMR_SID_MUST_CFG_SWITCH,
CMP_UU_FDPCH_COMPAT_SWITCH,
CMP_UU_IGNORE_UE_RLC_CAP_SWITCH,
CMP_UU_INTRA_FREQ_MC_BESTCELL_CIO_SWITCH,
CMP_UU_IOS_CELL_SYNC_INFO_REPORT_SWITCH,
CMP_UU_SERV_CELL_CHG_WITH_ASU_SWITCH,
CMP_UU_SERV_CELL_CHG_WITH_RB_MOD_SWITCH,
CMP_UU_VOIP_UP_PROC_AS_NORMAL_PS_SWITCH,
CMP_F2F_RLC_ONESIDE_REBUILD_SWITCH,
CMP_D2F_RLC_ONESIDE_REBUILD_SWITCH,
CMP_RAB_5_CFG_ROHC_SWITCH,
CMP_RAB_6_CFG_ROHC_SWITCH,
CMP_RAB_7_CFG_ROHC_SWITCH,
CMP_RAB_8_CFG_ROHC_SWITCH,
CMP_RAB_9_CFG_ROHC_SWITCH,
CMP_HSUPA_MACD_FLOW_MUL_SWITCH,
CMP_SMLC_RSLT_MODE_TYPE_SWITCH,
CMP_F2P_PROCESS_OPTIMIZATION_SWITCH,
CMP_UU_SIB11_SIB12_WITH_1A1D_SWITCH
Default Value:
CMP_IU_IMS_PROC_AS_NORMAL_PS_SWITCH:0,CMP_I
U_QOS_ASYMMETRY_IND_COMPAT_SWITCH:0,CMP_IU
_SYSHOIN_CMP_IUUP_FIXTO1_SWITCH:0,CMP_IUR_H2
D_FOR_LOWR5_NRNCCELL_SWITCH:0,CMP_IUR_SHO_
DIVCTRL_SWITCH:0,CMP_UU_ADJACENT_FREQ_CM_S
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
WITCH:0,CMP_UU_AMR_DRD_HHO_COMPAT_SWITCH:1
,CMP_UU_AMR_SID_MUST_CFG_SWITCH:0,CMP_UU_FD
PCH_COMPAT_SWITCH:0,CMP_UU_IGNORE_UE_RLC_C
AP_SWITCH:1,CMP_UU_INTRA_FREQ_MC_BESTCELL_C
IO_SWITCH:0,CMP_UU_IOS_CELL_SYNC_INFO_REPORT
_SWITCH:0,CMP_UU_SERV_CELL_CHG_WITH_ASU_SWI
TCH:0,CMP_UU_SERV_CELL_CHG_WITH_RB_MOD_SWI
TCH:1,CMP_UU_VOIP_UP_PROC_AS_NORMAL_PS_SWIT
CH:1,CMP_F2F_RLC_ONESIDE_REBUILD_SWITCH:0,CMP
_D2F_RLC_ONESIDE_REBUILD_SWITCH:0,CMP_RAB_5_
CFG_ROHC_SWITCH:0,CMP_RAB_6_CFG_ROHC_SWITC
H:0,CMP_RAB_7_CFG_ROHC_SWITCH:0,CMP_RAB_8_CF
G_ROHC_SWITCH:0,CMP_RAB_9_CFG_ROHC_SWITCH:0,
CMP_HSUPA_MACD_FLOW_MUL_SWITCH:0,CMP_SMLC
_RSLT_MODE_TYPE_SWITCH:0,CMP_F2P_PROCESS_OPT
IMIZATION_SWITCH:0,CMP_UU_SIB11_SIB12_WITH_1A1
D_SWITCH:0
HHO B ADD W Intr Meaning: Indicating whether to trigger hard handover cross the
TRIG S UNR RF a Iur interface between the RNC and the neighboring RNC.
C NC D- Fre GUI Value Range: OFF, ON
6 MOD 02 que Unit: None
9 UNR 03 ncy
Actual Value Range: OFF, ON
0 NC 01 Har
0 d Default Value: None
W
RF Han
D- dov
02 er
03 Inte
02 r
W Fre
RF que
D- ncy
02 Har
03 d
04 Han
W dov
RF er
D- Bas
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
04 ed
02 on
02 Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
RN
C
Nod
e
Red
und
anc
y
HHO B ADD W Intr Meaning: Indicating whether to trigger hard handover cross the
TRIG S UNR RF a Iur interface between the RNC and the neighboring RNC.
C NC D- Fre GUI Value Range: OFF, ON
6 MOD 02 que Unit: None
9 UNR 03 ncy
Actual Value Range: OFF, ON
1 NC 01 Har
0 d Default Value: None
W
RF Han
D- dov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
02 er
03 Inte
02 r
W Fre
RF que
D- ncy
02 Har
03 d
04 Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
SHOT B ADD W Inte Meaning: Indicating whether to trigger soft handover cross the
RIG S UNR RF r Iur interface between the RNC and the neighboring RNC: 1)
C NC D- RN CS_SHO_SWITCH. Indicating whether to trigger soft handover
6 MOD 02 C for CS cross the Iur interface. 2) HSPA_SHO_SWITCH.
9 UNR 02 Soft Whether to allow inter-Iur soft handovers for HSPA PS services.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
SHOT B ADD W Inte Meaning: Indicating whether to trigger soft handover cross the
RIG S UNR RF r Iur interface between the RNC and the neighboring RNC: 1)
C NC D- RN CS_SHO_SWITCH. Indicating whether to trigger soft handover
6 MOD 02 C for CS cross the Iur interface. 2) HSPA_SHO_SWITCH.
9 UNR 02 Soft Whether to allow inter-Iur soft handovers for HSPA PS services.
1 NC 03 Han When this switch is turned on, a UE processing HSUPA or
0 M dov HSDPA PS services can initiate a serving cell change process to
RF er the neighboring RNC. Alternatively, the UE can initiate a soft
D- Inte handover process and meanwhile changes the existing channel to
21 rfac a DCH. When this switch is turned off, the UE cannot perform
08 e any of the previous operations. 3) NON_HSPA_SHO_SWITCH.
01 Mes Indicating whether to trigger soft handover for PS(R99) cross the
sag Iur interface.
e GUI Value Range: CS_SHO_SWITCH, HSPA_SHO_SWITCH,
Tra NON_HSPA_SHO_SWITCH
cing Unit: None
Actual Value Range: CS_SHO_SWITCH,
HSPA_SHO_SWITCH, NON_HSPA_SHO_SWITCH
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Unit: None
Actual Value Range: CPICH_EC/NO, CPICH_RSCP
Default Value: CPICH_EC/NO
MaxC B ADD W Inte Meaning: Maximum number of cells in an active set. This
ellInA S UCE RF r parameter is used to achieve the balance between the signal
ctiveS C LLIN D- RN quality in the SHO area and the system performance. If more
et 6 TRAF 02 C cells are in the active set, a user can obtain a greater macro
9 REQ 02 Soft diversity gain; the intra-frequency interference is smaller. In this
0 HO 03 Han case, however, the user occupies resources of several cells. This
0 MOD W dov increases the amount of data to be processed and lowers the
UCE RF er system performance.
LLIN D- Intr GUI Value Range: 1~6
TRAF 02 a Unit: None
REQ 02 RN Actual Value Range: 1~6
HO 02 C
Default Value: 3
Soft
Han
dov
er
MaxC B ADD W Inte Meaning: Maximum number of cells in an active set. This
ellInA S UCE RF r parameter is used to achieve the balance between the signal
ctiveS C LLIN D- RN quality in the SHO area and the system performance. If more
et 6 TRAF 02 C cells are in the active set, a user can obtain a greater macro
9 REQ 02 Soft diversity gain; the intra-frequency interference is smaller. In this
1 HO 03 Han case, however, the user occupies resources of several cells. This
0 MOD W dov increases the amount of data to be processed and lowers the
UCE RF er system performance.
LLIN D- Intr GUI Value Range: 1~6
TRAF 02 a Unit: None
REQ 02 RN Actual Value Range: 1~6
HO 02 C
Default Value: 3
Soft
Han
dov
er
CIO B ADD W Intr Meaning: Cell individual offset (CIO) of the current cell. This
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
02 Fre
03 que
04 ncy
W Har
RF d
D- Han
02 dov
03 er
05 Bas
ed
on
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
on
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
CIO B ADD W Intr Meaning: Cell individual offset (CIO) of the current cell. This
S UCE RF a parameter works together with "CIOOffset" for intra-frequency
C LLSE D- Nod and inter-frequency handover decision. The larger the sum of the
6 TUP 02 eB values of this parameter and "CIOOffset", the higher the
9 MOD 02 Soft probability of handover to the neighboring cell. The smaller the
1 UCE 01 er sum of the values of this parameter and "CIOOffset", the lower
0 LLSE W Han the probability of handover to the neighboring cell. For details
TUP RF dov about this parameter, see 3GPP TS 25.331.
D- er GUI Value Range: -20~20
02 Inte Unit: 0.5dB
02 r Actual Value Range: -10~10
03 RN
Default Value: 0
W C
RF Soft
D- Han
02 dov
02 er
02 Intr
W a
RF RN
D- C
02 Soft
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
03 Han
09 dov
W er
RF Inte
D- r-
02 RA
03 T
02 Han
W dov
RF er
D- Bas
02 ed
03 on
03 DL
W Qo
RF S
D- Inte
02 r
03 Fre
04 que
W ncy
RF Har
D- d
02 Han
03 dov
05 er
Bas
ed
on
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
CIOO B ADD W Intr Meaning: CIO of a neighboring cell. This parameter works with
ffset S UINT RF a "CIO". The sum of "CIOOffset", "CIO", and the actual measured
C RAF D- Nod value are used for UE event evaluation or decisions on
6 REQ 02 eB handovers triggered by the RNC. In a handover algorithm, this
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
9 NCE 02 Soft parameter is used for moving the border of a cell. In the case of
0 LL 01 er an event-based intra-frequency measurement or inter-RAT
0 MOD Han measurement, the UE determines whether to trigger an event
UINT dov according to the sum of "CIOOffset", "CIO", and the actual
RAF er measured value. The UE does not consider the value of this
REQ parameter when evaluating an inter-frequency measurement
NCE event. In the case of a periodical inter-frequency measurement or
LL inter-RAT measurement, the RNC determines whether to initiate
a handover based on the sum of "CIOOffset", "CIO", and the
actual measured value.
GUI Value Range: -20~20
Unit: 0.5dB
Actual Value Range: -10~10
Default Value: 0
CIOO B ADD W Intr Meaning: CIO of a neighboring cell. This parameter works with
ffset S UINT RF a "CIO". The sum of "CIOOffset", "CIO", and the actual measured
C RAF D- Nod value are used for UE event evaluation or decisions on
6 REQ 02 eB handovers triggered by the RNC. In a handover algorithm, this
9 NCE 02 Soft parameter is used for moving the border of a cell. In the case of
1 LL 01 er an event-based intra-frequency measurement or inter-RAT
0 MOD Han measurement, the UE determines whether to trigger an event
UINT dov according to the sum of "CIOOffset", "CIO", and the actual
RAF er measured value. The UE does not consider the value of this
REQ parameter when evaluating an inter-frequency measurement
NCE event. In the case of a periodical inter-frequency measurement or
LL inter-RAT measurement, the RNC determines whether to initiate
a handover based on the sum of "CIOOffset", "CIO", and the
actual measured value.
GUI Value Range: -20~20
Unit: 0.5dB
Actual Value Range: -10~10
Default Value: 0
Weigh B ADD W Inte Meaning: Used for calculating the relative threshold of the soft
t S UCE RF r handover based on the measurement report of each cell in the
C LLIN D- RN active set. If this parameter is set to a greater value, the relative
6 TRAF 02 C threshold of the soft handover is greater with the other conditions
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Weigh B ADD W Inte Meaning: Used for calculating the relative threshold of the soft
t S UCE RF r handover based on the measurement report of each cell in the
C LLIN D- RN active set. If this parameter is set to a greater value, the relative
6 TRAF 02 C threshold of the soft handover is greater with the other conditions
9 REQ 02 Soft unchanged. For detailed information of this parameter, refer to
1 HO 03 Han 3GPP TS 25.133. When this parameter is set to 0, the general
0 MOD W dov quality of the active set is the quality of the best cell. In this case,
UCE RF er the relative threshold of soft handover depends on the related
LLIN D- Intr measurement values of the best cell in the active set. When this
TRAF 02 a parameter is set to 1, the relative threshold of the soft handover
REQ 02 RN depends on the equivalent signal strength obtained when
HO 02 C maximum ratio combining is performed in the downlink of all
Soft cells in the active set.
Han GUI Value Range: 0~20
dov Unit: None
er Actual Value Range: 0~2, step: 0.1
Default Value: 0
0 MOD W dov threshold of event 1A is affected when the cell is added to the
UINT RF er active set. That is, the cell signals are involved when the UE
RAF D- Intr evaluates whether event 1A should be triggered.
REQ 02 a GUI Value Range: AFFECT, NOT_AFFECT
NCE 02 RN Unit: None
LL 02 C Actual Value Range: AFFECT, NOT_AFFECT
Soft
Default Value: AFFECT
Han
dov
er
IntraR B SET W Inte Meaning: Relative threshold for event 1A decision when non-VP
elThd S UINT RF r service is performed in CS domain. If this parameter is set to a
For1A C RAF D- RN greater value, the probability of triggering event 1A increases. If
CSNV 6 REQ 02 C this parameter is set to a smaller value, the probability of
P 9 HO 02 Soft triggering event 1A reduces. For details on the definition of
0 03 Han event 1A, see 3GPP TS 25.331.The relative threshold can
0 W dov directly affect the SHO ratio. Therefore, the threshold should be
RF er wisely chosen to achieve smooth SHOs. The value of this
D- Intr parameter determines the SHO area and SHO ratio. In the
02 a CDMA system, the ratio of the UE involved in soft handover
02 RN should reach 30% to 40% to ensure smooth handover. Based on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraR B SET W Inte Meaning: Relative threshold for event 1A decision when non-VP
elThd S UINT RF r service is performed in CS domain. If this parameter is set to a
For1A C RAF D- RN greater value, the probability of triggering event 1A increases. If
CSNV 6 REQ 02 C this parameter is set to a smaller value, the probability of
P 9 HO 02 Soft triggering event 1A reduces. For details on the definition of
1 03 Han event 1A, see 3GPP TS 25.331.The relative threshold can
0 W dov directly affect the SHO ratio. Therefore, the threshold should be
RF er wisely chosen to achieve smooth SHOs. The value of this
D- Intr parameter determines the SHO area and SHO ratio. In the
02 a CDMA system, the ratio of the UE involved in soft handover
02 RN should reach 30% to 40% to ensure smooth handover. Based on
02 C simulation results, when the relative threshold is set to 5 dB, the
Soft ratio of the UE involved in soft handover (the number of cells in
Han the active set is at least 2) is about 35%. you are advised to set
dov the relative threshold to a great value (5 dB to 7 dB) during site
er deployment, and to reduce the threshold when the users increase.
the threshold must be higher than 3 dB to avoid the ping-pong
handover. You can set different relative thresholds for event 1A
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
and event 1B to reduce the ping-pong effect and change the soft
handover ratio. In general applications, the relative thresholds for
events 1A and 1B should be consistent, and you can curb the
ping-pong effect through the triggering delay, L3 filtering
coefficient, and hysteresis. In some specific applications, if the
ping-pong effect cannot be curbed by adjusting the hysteresis
values for event 1A and event 1B, you can curb it by setting a
higher relative threshold for event 1B and a lower threshold for
event 1A.
GUI Value Range: 0~29
Unit: 0.5dB
Actual Value Range: 0~14.5
Default Value: 6
IntraR B ADD W Inte Meaning: Relative threshold for event 1A decision when VP
elThd S UCE RF r service is performed. If this parameter is set to a greater value,
For1A C LLIN D- RN the probability of triggering event 1A increases. If this parameter
CSVP 6 TRAF 02 C is set to a smaller value, the probability of triggering event 1A
9 REQ 02 Soft reduces. For details on the definition of event 1A, see 3GPP TS
0 HO 03 Han 25.331.The relative threshold can directly affect the SHO ratio.
0 MOD W dov Therefore, the threshold should be wisely chosen to achieve
UCE RF er smooth SHOs. The value of this parameter determines the SHO
LLIN D- Intr area and SHO ratio. In the CDMA system, the ratio of the UE
TRAF 02 a involved in soft handover should reach 30% to 40% to ensure
REQ 02 RN smooth handover. Based on simulation results, when the relative
HO 02 C threshold is set to 5 dB, the ratio of the UE involved in soft
Soft handover (the number of cells in the active set is at least 2) is
Han about 35%. you are advised to set the relative threshold to a great
dov value (5 dB to 7 dB) during site deployment, and to reduce the
er threshold when the users increase. the threshold must be higher
than 3 dB to avoid the ping-pong handover. You can set different
relative thresholds for event 1A and event 1B to reduce the ping-
pong effect and change the soft handover ratio. In general
applications, the relative thresholds for events 1A and 1B should
be consistent, and you can curb the ping-pong effect through the
triggering delay, L3 filtering coefficient, and hysteresis. In some
specific applications, if the ping-pong effect cannot be curbed by
adjusting the hysteresis values for event 1A and event 1B, you
can curb it by setting a higher relative threshold for event 1B and
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraR B ADD W Inte Meaning: Relative threshold for event 1A decision when VP
elThd S UCE RF r service is performed. If this parameter is set to a greater value,
For1A C LLIN D- RN the probability of triggering event 1A increases. If this parameter
CSVP 6 TRAF 02 C is set to a smaller value, the probability of triggering event 1A
9 REQ 02 Soft reduces. For details on the definition of event 1A, see 3GPP TS
1 HO 03 Han 25.331.The relative threshold can directly affect the SHO ratio.
0 MOD W dov Therefore, the threshold should be wisely chosen to achieve
UCE RF er smooth SHOs. The value of this parameter determines the SHO
LLIN D- Intr area and SHO ratio. In the CDMA system, the ratio of the UE
TRAF 02 a involved in soft handover should reach 30% to 40% to ensure
REQ 02 RN smooth handover. Based on simulation results, when the relative
HO 02 C threshold is set to 5 dB, the ratio of the UE involved in soft
Soft handover (the number of cells in the active set is at least 2) is
Han about 35%. you are advised to set the relative threshold to a great
dov value (5 dB to 7 dB) during site deployment, and to reduce the
er threshold when the users increase. the threshold must be higher
than 3 dB to avoid the ping-pong handover. You can set different
relative thresholds for event 1A and event 1B to reduce the ping-
pong effect and change the soft handover ratio. In general
applications, the relative thresholds for events 1A and 1B should
be consistent, and you can curb the ping-pong effect through the
triggering delay, L3 filtering coefficient, and hysteresis. In some
specific applications, if the ping-pong effect cannot be curbed by
adjusting the hysteresis values for event 1A and event 1B, you
can curb it by setting a higher relative threshold for event 1B and
a lower threshold for event 1A.
GUI Value Range: 0~29
Unit: 0.5dB
Actual Value Range: 0~14.5
Default Value: 6
IntraR B ADD W Inte Meaning: Relative threshold for event 1A decision when PS
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraR B ADD W Inte Meaning: Relative threshold for event 1A decision when PS
elThd S UCE RF r service is performed. If this parameter is set to a greater value,
For1A C LLIN D- RN the probability of triggering event 1A increases. If this parameter
PS 6 TRAF 02 C is set to a smaller value, the probability of triggering event 1A
9 REQ 02 Soft reduces. For details on the definition of event 1A, see 3GPP TS
1 HO 03 Han 25.331. The relative threshold can directly affect the SHO ratio.
0 MOD W dov Therefore, the threshold should be wisely chosen to achieve
UCE RF er smooth SHOs. The value of this parameter determines the SHO
LLIN D- area and SHO ratio. In the CDMA system, the ratio of the UE
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TRAF 02 Intr involved in soft handover should reach 30% to 40% to ensure
REQ 02 a smooth handover. Based on simulation results, when the relative
HO 02 RN threshold is set to 5 dB, the ratio of the UE involved in soft
C handover (the number of cells in the active set is at least 2) is
Soft about 35%. You are advised to set the relative threshold to a
Han great value (5 dB to 7 dB) during site deployment, and to reduce
dov the threshold when the users increase. the threshold must be
er higher than 3 dB to avoid the ping-pong handover. You can set
different relative thresholds for event 1A and event 1B to reduce
the ping-pong effect and change the soft handover ratio. In
general applications, the relative thresholds for events 1A and 1B
should be consistent, and you can curb the ping-pong effect
through the triggering delay, L3 filtering coefficient, and
hysteresis. In some specific applications, if the ping-pong effect
cannot be curbed by adjusting the hysteresis values for event 1A
and event 1B, you can curb it by setting a higher relative
threshold for event 1B and a lower threshold for event 1A.
GUI Value Range: 0~29
Unit: 0.5dB
Actual Value Range: 0~14.5
Default Value: 6
HystF B ADD W Inte Meaning: Hysteresis for triggering event 1A. For details, see
or1A S UCE RF r 3GPP TS 25.331. This parameter can be used to reduce ping-
C LLIN D- RN pong handovers and unnecessary handovers. When adjusting the
6 TRAF 02 C setting of this parameter, you need to consider the filter
9 REQ 02 Soft coefficient and the interval between detection of event 1A and
0 HO 03 Han sending of the measurement report.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 0
REQ 02 RN
HO 02 C
Soft
Han
dov
er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
HystF B ADD W Inte Meaning: Hysteresis for triggering event 1A. For details, see
or1A S UCE RF r 3GPP TS 25.331. This parameter can be used to reduce ping-
C LLIN D- RN pong handovers and unnecessary handovers. When adjusting the
6 TRAF 02 C setting of this parameter, you need to consider the filter
9 REQ 02 Soft coefficient and the interval between detection of event 1A and
1 HO 03 Han sending of the measurement report.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 0
REQ 02 RN
HO 02 C
Soft
Han
dov
er
IntraR B ADD W Inte Meaning: Relative threshold for event 1A decision when non-VP
elThd S UCE RF r service is performed in CS domain. If this parameter is set to a
For1A C LLIN D- RN greater value, the probability of triggering event 1A increases. If
CSNV 6 TRAF 02 C this parameter is set to a smaller value, the probability of
P 9 REQ 02 Soft triggering event 1A reduces. For details on the definition of
0 HO 03 Han event 1A, see 3GPP TS 25.331.The relative threshold can
0 MOD W dov directly affect the SHO ratio. Therefore, the threshold should be
UCE RF er wisely chosen to achieve smooth SHOs. The value of this
LLIN D- Intr parameter determines the SHO area and SHO ratio. In the
TRAF 02 a CDMA system, the ratio of the UE involved in soft handover
REQ 02 RN should reach 30% to 40% to ensure smooth handover. Based on
HO 02 C simulation results, when the relative threshold is set to 5 dB, the
Soft ratio of the UE involved in soft handover (the number of cells in
Han the active set is at least 2) is about 35%. you are advised to set
dov the relative threshold to a great value (5 dB to 7 dB) during site
er deployment, and to reduce the threshold when the users increase.
the threshold must be higher than 3 dB to avoid the ping-pong
handover. You can set different relative thresholds for event 1A
and event 1B to reduce the ping-pong effect and change the soft
handover ratio. In general applications, the relative thresholds for
events 1A and 1B should be consistent, and you can curb the
ping-pong effect through the triggering delay, L3 filtering
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraR B ADD W Inte Meaning: Relative threshold for event 1A decision when non-VP
elThd S UCE RF r service is performed in CS domain. If this parameter is set to a
For1A C LLIN D- RN greater value, the probability of triggering event 1A increases. If
CSNV 6 TRAF 02 C this parameter is set to a smaller value, the probability of
P 9 REQ 02 Soft triggering event 1A reduces. For details on the definition of
1 HO 03 Han event 1A, see 3GPP TS 25.331.The relative threshold can
0 MOD W dov directly affect the SHO ratio. Therefore, the threshold should be
UCE RF er wisely chosen to achieve smooth SHOs. The value of this
LLIN D- Intr parameter determines the SHO area and SHO ratio. In the
TRAF 02 a CDMA system, the ratio of the UE involved in soft handover
REQ 02 RN should reach 30% to 40% to ensure smooth handover. Based on
HO 02 C simulation results, when the relative threshold is set to 5 dB, the
Soft ratio of the UE involved in soft handover (the number of cells in
Han the active set is at least 2) is about 35%. you are advised to set
dov the relative threshold to a great value (5 dB to 7 dB) during site
er deployment, and to reduce the threshold when the users increase.
the threshold must be higher than 3 dB to avoid the ping-pong
handover. You can set different relative thresholds for event 1A
and event 1B to reduce the ping-pong effect and change the soft
handover ratio. In general applications, the relative thresholds for
events 1A and 1B should be consistent, and you can curb the
ping-pong effect through the triggering delay, L3 filtering
coefficient, and hysteresis. In some specific applications, if the
ping-pong effect cannot be curbed by adjusting the hysteresis
values for event 1A and event 1B, you can curb it by setting a
higher relative threshold for event 1B and a lower threshold for
event 1A.
GUI Value Range: 0~29
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Unit: 0.5dB
Actual Value Range: 0~14.5
Default Value: 6
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1A S UCE RF r detection of event 1A and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
0 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
REQ 02 RN appropriate triggering delay effectively reduces the average
HO 02 C number of handovers and the number of wrong handovers,
W Soft preventing unnecessary handovers. If the handover cannot be
RF Han triggered in time, the time-to-trigger parameter for event 1A
D- dov needs to be changed to 200 ms or 100 ms, and the delay for
15 er event 1B needs to be changed to 1280 ms or 2560 ms.
02 Lay GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
05 ered D160, D200, D240, D320, D640, D1280, D2560, D5000
Pag Unit: ms
ing Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
in 240, 320, 640, 1280, 2560, 5000
Idle Default Value: D320
Mo
de
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1A S UCE RF r detection of event 1A and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
1 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CellsF B ADD W Inte Meaning: Flag of whether adding a cell into the active set will
orbidd S UINT RF r affect the relative threshold of the event 1B. This parameter is a
en1B C RAF D- RN flag of whether adding the cell into the active set will affect the
6 REQ 02 C relative threshold of the event 1B NOT_AFFECT: Adding the
9 NCE 02 Soft cell into the active set does not affect the relative threshold of the
0 LL 03 Han event 1B. The cell signal will affect the UE evaluate whether
0 MOD W dov event 1B should occur. AFFECT: Adding the cell into the active
UINT RF er set affects the relative threshold of the event 1B. The cell signal
RAF D- Intr will not affect the UE evaluate whether event 1B should occur.
REQ 02 a GUI Value Range: AFFECT, NOT_AFFECT
NCE 02 RN Unit: None
LL 02 C Actual Value Range: AFFECT, NOT_AFFECT
Soft
Default Value: AFFECT
Han
dov
er
CellsF B ADD W Inte Meaning: Flag of whether adding a cell into the active set will
orbidd S UINT RF r affect the relative threshold of the event 1B. This parameter is a
en1B C RAF D- RN flag of whether adding the cell into the active set will affect the
6 REQ 02 C relative threshold of the event 1B NOT_AFFECT: Adding the
9 NCE 02 Soft cell into the active set does not affect the relative threshold of the
1 LL 03 Han event 1B. The cell signal will affect the UE evaluate whether
0 MOD W dov event 1B should occur. AFFECT: Adding the cell into the active
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UINT RF er set affects the relative threshold of the event 1B. The cell signal
RAF D- Intr will not affect the UE evaluate whether event 1B should occur.
REQ 02 a GUI Value Range: AFFECT, NOT_AFFECT
NCE 02 RN Unit: None
LL 02 C Actual Value Range: AFFECT, NOT_AFFECT
Soft
Default Value: AFFECT
Han
dov
er
IntraR B ADD W Inte Meaning: Relative threshold for event 1B decision when non-VP
elThd S UCE RF r service is performed in CS domain. If this parameter is set to a
For1B C LLIN D- RN smaller value, the probability of triggering event 1B increases. If
CSNV 6 TRAF 02 C this parameter is set to a greater value, the probability of
P 9 REQ 02 Soft triggering event 1B reduces. For details on the definition of
0 HO 03 Han event 1B, see 3GPP TS 25.331. The relative threshold can
0 MOD W dov directly affect the SHO ratio. Therefore, the threshold should be
UCE RF er wisely chosen to achieve smooth SHOs. The value of this
LLIN D- Intr parameter determines the SHO area and SHO ratio. In the
TRAF 02 a CDMA system, the ratio of the UE involved in soft handover
REQ 02 RN should reach 30% to 40% to ensure smooth handover. Based on
HO 02 C simulation results, when the relative threshold is set to 5 dB, the
Soft ratio of the UE involved in soft handover (the number of cells in
Han the active set is at least 2) is about 35%. You are advised to set
dov the relative threshold to a great value (5 dB to 7 dB) during site
er deployment, and to reduce the threshold when the users increase.
the threshold must be higher than 3 dB to avoid the ping-pong
handover. You can set different relative thresholds for event 1A
and event 1B to reduce the ping-pong effect and change the soft
handover ratio. In general applications, the relative thresholds for
events 1A and 1B should be consistent, and you can curb the
ping-pong effect through the triggering delay, L3 filtering
coefficient, and hysteresis. In some specific applications, if the
ping-pong effect cannot be curbed by adjusting the hysteresis
values for event 1A and event 1B, you can curb it by setting a
higher relative threshold for event 1B and a lower threshold for
event 1A.
GUI Value Range: 0~29
Unit: 0.5dB
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraR B ADD W Inte Meaning: Relative threshold for event 1B decision when non-VP
elThd S UCE RF r service is performed in CS domain. If this parameter is set to a
For1B C LLIN D- RN smaller value, the probability of triggering event 1B increases. If
CSNV 6 TRAF 02 C this parameter is set to a greater value, the probability of
P 9 REQ 02 Soft triggering event 1B reduces. For details on the definition of
1 HO 03 Han event 1B, see 3GPP TS 25.331. The relative threshold can
0 MOD W dov directly affect the SHO ratio. Therefore, the threshold should be
UCE RF er wisely chosen to achieve smooth SHOs. The value of this
LLIN D- Intr parameter determines the SHO area and SHO ratio. In the
TRAF 02 a CDMA system, the ratio of the UE involved in soft handover
REQ 02 RN should reach 30% to 40% to ensure smooth handover. Based on
HO 02 C simulation results, when the relative threshold is set to 5 dB, the
Soft ratio of the UE involved in soft handover (the number of cells in
Han the active set is at least 2) is about 35%. You are advised to set
dov the relative threshold to a great value (5 dB to 7 dB) during site
er deployment, and to reduce the threshold when the users increase.
the threshold must be higher than 3 dB to avoid the ping-pong
handover. You can set different relative thresholds for event 1A
and event 1B to reduce the ping-pong effect and change the soft
handover ratio. In general applications, the relative thresholds for
events 1A and 1B should be consistent, and you can curb the
ping-pong effect through the triggering delay, L3 filtering
coefficient, and hysteresis. In some specific applications, if the
ping-pong effect cannot be curbed by adjusting the hysteresis
values for event 1A and event 1B, you can curb it by setting a
higher relative threshold for event 1B and a lower threshold for
event 1A.
GUI Value Range: 0~29
Unit: 0.5dB
Actual Value Range: 0~14.5
Default Value: 12
IntraR B ADD W Inte Meaning: Relative threshold for event 1B decision when VP
elThd S UCE RF r service is performed. If this parameter is set to a smaller value,
For1B C LLIN D- RN the probability of triggering event 1B increases. If this parameter
CSVP 6 TRAF 02 C is set to a greater value, the probability of triggering event 1B
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
9 REQ 02 Soft reduces. For details on the definition of event 1B, see 3GPP TS
0 HO 03 Han 25.331. The relative threshold can directly affect the SHO ratio.
0 MOD W dov Therefore, the threshold should be wisely chosen to achieve
UCE RF er smooth SHOs. The value of this parameter determines the SHO
LLIN D- Intr area and SHO ratio. In the CDMA system, the ratio of the UE
TRAF 02 a involved in soft handover should reach 30% to 40% to ensure
REQ 02 RN smooth handover. Based on simulation results, when the relative
HO 02 C threshold is set to 5 dB, the ratio of the UE involved in soft
Soft handover (the number of cells in the active set is at least 2) is
Han about 35%. You are advised to set the relative threshold to a
dov great value (5 dB to 7 dB) during site deployment, and to reduce
er the threshold when the users increase. the threshold must be
higher than 3 dB to avoid the ping-pong handover. You can set
different relative thresholds for event 1A and event 1B to reduce
the ping-pong effect and change the soft handover ratio. In
general applications, the relative thresholds for events 1A and 1B
should be consistent, and you can curb the ping-pong effect
through the triggering delay, L3 filtering coefficient, and
hysteresis. In some specific applications, if the ping-pong effect
cannot be curbed by adjusting the hysteresis values for event 1A
and event 1B, you can curb it by setting a higher relative
threshold for event 1B and a lower threshold for event 1A.
GUI Value Range: 0~29
Unit: 0.5dB
Actual Value Range: 0~14.5
Default Value: 12
IntraR B ADD W Inte Meaning: Relative threshold for event 1B decision when VP
elThd S UCE RF r service is performed. If this parameter is set to a smaller value,
For1B C LLIN D- RN the probability of triggering event 1B increases. If this parameter
CSVP 6 TRAF 02 C is set to a greater value, the probability of triggering event 1B
9 REQ 02 Soft reduces. For details on the definition of event 1B, see 3GPP TS
1 HO 03 Han 25.331. The relative threshold can directly affect the SHO ratio.
0 MOD W dov Therefore, the threshold should be wisely chosen to achieve
UCE RF er smooth SHOs. The value of this parameter determines the SHO
LLIN D- Intr area and SHO ratio. In the CDMA system, the ratio of the UE
TRAF 02 a involved in soft handover should reach 30% to 40% to ensure
REQ 02 RN smooth handover. Based on simulation results, when the relative
HO 02 C threshold is set to 5 dB, the ratio of the UE involved in soft
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraR B ADD W Inte Meaning: Relative threshold for event 1B decision when PS
elThd S UCE RF r service is performed. If this parameter is set to a smaller value,
For1B C LLIN D- RN the probability of triggering event 1B increases. If this parameter
PS 6 TRAF 02 C is set to a greater value, the probability of triggering event 1B
9 REQ 02 Soft reduces. For details on the definition of event 1B, see 3GPP TS
0 HO 03 Han 25.331. The relative threshold can directly affect the SHO ratio.
0 MOD W dov Therefore, the threshold should be wisely chosen to achieve
UCE RF er smooth SHOs. The value of this parameter determines the SHO
LLIN D- Intr area and SHO ratio. In the CDMA system, the ratio of the UE
TRAF 02 a involved in soft handover should reach 30% to 40% to ensure
REQ 02 RN smooth handover. Based on simulation results, when the relative
HO 02 C threshold is set to 5 dB, the ratio of the UE involved in soft
Soft handover (the number of cells in the active set is at least 2) is
Han about 35%. You are advised to set the relative threshold to a
dov great value (5 dB to 7 dB) during site deployment, and to reduce
er the threshold when the users increase. the threshold must be
higher than 3 dB to avoid the ping-pong handover. You can set
different relative thresholds for event 1A and event 1B to reduce
the ping-pong effect and change the soft handover ratio. In
general applications, the relative thresholds for events 1A and 1B
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraR B ADD W Inte Meaning: Relative threshold for event 1B decision when PS
elThd S UCE RF r service is performed. If this parameter is set to a smaller value,
For1B C LLIN D- RN the probability of triggering event 1B increases. If this parameter
PS 6 TRAF 02 C is set to a greater value, the probability of triggering event 1B
9 REQ 02 Soft reduces. For details on the definition of event 1B, see 3GPP TS
1 HO 03 Han 25.331. The relative threshold can directly affect the SHO ratio.
0 MOD W dov Therefore, the threshold should be wisely chosen to achieve
UCE RF er smooth SHOs. The value of this parameter determines the SHO
LLIN D- Intr area and SHO ratio. In the CDMA system, the ratio of the UE
TRAF 02 a involved in soft handover should reach 30% to 40% to ensure
REQ 02 RN smooth handover. Based on simulation results, when the relative
HO 02 C threshold is set to 5 dB, the ratio of the UE involved in soft
Soft handover (the number of cells in the active set is at least 2) is
Han about 35%. You are advised to set the relative threshold to a
dov great value (5 dB to 7 dB) during site deployment, and to reduce
er the threshold when the users increase. the threshold must be
higher than 3 dB to avoid the ping-pong handover. You can set
different relative thresholds for event 1A and event 1B to reduce
the ping-pong effect and change the soft handover ratio. In
general applications, the relative thresholds for events 1A and 1B
should be consistent, and you can curb the ping-pong effect
through the triggering delay, L3 filtering coefficient, and
hysteresis. In some specific applications, if the ping-pong effect
cannot be curbed by adjusting the hysteresis values for event 1A
and event 1B, you can curb it by setting a higher relative
threshold for event 1B and a lower threshold for event 1A.
GUI Value Range: 0~29
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Unit: 0.5dB
Actual Value Range: 0~14.5
Default Value: 12
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1B S UCE RF r 1B. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
0 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 0
REQ 02 RN
HO 02 C
Soft
Han
dov
er
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1B S UCE RF r 1B. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
1 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 0
REQ 02 RN
HO 02 C
Soft
Han
dov
er
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1B S UCE RF r detection of event 1B and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
1 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
REQ 02 RN appropriate interval time effectively reduces the average number
HO 02 C of handovers and the number of wrong handovers, preventing
Soft unnecessary handovers. If the handover cannot be triggered in
Han time, the time-to-trigger parameter for event 1A needs to be
dov changed to 200 ms or 100 ms, and the delay for event 1B needs
er to be changed to 1280 ms or 2560 ms.
GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1C S UCE RF r 1C. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
0 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 8
REQ 02 RN
HO 02 C
Soft
Han
dov
er
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1C S UCE RF r 1C. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
1 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 8
REQ 02 RN
HO 02 C
Soft
Han
dov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1C S UCE RF r detection of event 1C and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
0 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
REQ 02 RN appropriate interval time effectively reduces the average number
HO 02 C of handovers and the number of wrong handovers, preventing
Soft unnecessary handovers.
Han GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
dov D160, D200, D240, D320, D640, D1280, D2560, D5000
er Unit: ms
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
240, 320, 640, 1280, 2560, 5000
Default Value: D640
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1C S UCE RF r detection of event 1C and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
1 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
REQ 02 RN appropriate interval time effectively reduces the average number
HO 02 C of handovers and the number of wrong handovers, preventing
Soft unnecessary handovers.
Han GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
dov D160, D200, D240, D320, D640, D1280, D2560, D5000
er Unit: ms
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
240, 320, 640, 1280, 2560, 5000
Default Value: D640
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1D S UCE RF r 1D. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
0 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 8
REQ 02 RN
HO 02 C
Soft
Han
dov
er
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1D S UCE RF r 1D. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
1 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 8
REQ 02 RN
HO 02 C
Soft
Han
dov
er
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1D S UCE RF r detection of event 1D and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
1 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
REQ 02 RN appropriate interval time effectively reduces the average number
HO 02 C of handovers and the number of wrong handovers, preventing
Soft unnecessary handovers.
Han GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
dov D160, D200, D240, D320, D640, D1280, D2560, D5000
er Unit: ms
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
240, 320, 640, 1280, 2560, 5000
Default Value: D640
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
SHOQ B ADD W Inte Meaning: If events 1A, 1C, and 1D are reported to the RNC, the
ualmi S UCE RF r target cell can be added to the active set only when CPICH
n C LLIN D- RN Ec/No is greater than this parameter. This parameter is used to
6 TRAF 02 C set a baseline for the quality of the radio links to be added. The
9 REQ 02 Soft current events of soft handovers are defined on the basis of
0 HO 03 Han relative thresholds and have no requirement for the absolute
0 MOD W dov quality. If the signal quality of added cells is too poor, the
UCE RF er general quality of the active set cannot be improved. In this case,
LLIN D- Intr however, more downlink resources are occupied and more TPC
TRAF 02 a errors are caused, and the soft handover performance is
REQ 02 RN worsened. Therefore, this parameter is required.
HO 02 C GUI Value Range: -24~0
Soft Unit: dB
Han Actual Value Range: -24~0
dov
Default Value: -20
er
SHOQ B ADD W Inte Meaning: If events 1A, 1C, and 1D are reported to the RNC, the
ualmi S UCE RF r target cell can be added to the active set only when CPICH
n C LLIN D- RN Ec/No is greater than this parameter. This parameter is used to
6 TRAF 02 C set a baseline for the quality of the radio links to be added. The
9 REQ 02 Soft current events of soft handovers are defined on the basis of
1 HO 03 Han relative thresholds and have no requirement for the absolute
0 MOD W dov quality. If the signal quality of added cells is too poor, the
UCE RF er general quality of the active set cannot be improved. In this case,
LLIN D- Intr however, more downlink resources are occupied and more TPC
TRAF 02 a errors are caused, and the soft handover performance is
REQ 02 RN worsened. Therefore, this parameter is required.
HO 02 C GUI Value Range: -24~0
Soft Unit: dB
Han Actual Value Range: -24~0
dov
Default Value: -20
er
RelTh B SET W Inte Meaning: Relative threshold for immediate rate reduction after
dForD S UINT RF r soft handover failure. The rate reduction of the active set and soft
wnGr C RAF D- RN handover retry procedure can be triggered without intra-
d 6 REQ 02 C frequency measurement reports if the quality of the cell in the
9 HO 02 Soft active set fulfills the following criterion: Mnew > Mbest_cell -
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RelTh B SET W Inte Meaning: Relative threshold for immediate rate reduction after
dForD S UINT RF r soft handover failure. The rate reduction of the active set and soft
wnGr C RAF D- RN handover retry procedure can be triggered without intra-
d 6 REQ 02 C frequency measurement reports if the quality of the cell in the
9 HO 02 Soft active set fulfills the following criterion: Mnew > Mbest_cell -
1 03 Han RelThdForDwnGrd Mnew indicates the CPICH Ec/No
0 W dov measurement value of Cell1 where the UE fails to be admitted.
RF er Mbest_cell indicates the CPICH Ec/No measurement value in
D- Intr the latest measurement report of the best cell identified by the
02 a RNC according to 1D. RelThdForDwnGrd indicates the relative
02 RN threshold for immediate rate reduction and can be configured on
02 C the OMU server. If this parameter is set to 29, rate reduction
Soft after soft handover failure is disabled.
Han GUI Value Range: -29~29
dov Unit: 0.5dB
er Actual Value Range: -14.5~14.5
Default Value: 2
ShoFa B SET W Inte Meaning: Maximum allowed number of soft handover failures.
ilNum S UINT RF r This parameter specifies the maximum number of event
ForD C RAF D- RN reporting from the cell that fails to be added to the active set for
wnGr 6 REQ 02 C soft handovers. If the parameter value is reached, rate reduction
d 9 HO 02 Soft of the active set will be triggered and the cell will attempt to join
0 03 Han the active set again. This parameter needs to be considered in
0 W dov combination with the settings of rate reduction evaluation
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ShoFa B SET W Inte Meaning: Maximum allowed number of soft handover failures.
ilNum S UINT RF r This parameter specifies the maximum number of event
ForD C RAF D- RN reporting from the cell that fails to be added to the active set for
wnGr 6 REQ 02 C soft handovers. If the parameter value is reached, rate reduction
d 9 HO 02 Soft of the active set will be triggered and the cell will attempt to join
1 03 Han the active set again. This parameter needs to be considered in
0 W dov combination with the settings of rate reduction evaluation
RF er period("ShoFailPeriod") and the reporting intervals of events 1A
D- Intr and 1C("ReportIntervalfor1A" and "ReportIntervalfor1C").
02 a Otherwise, the number of reports cannot reach the required value
02 RN to trigger rate reduction during the rate reduction evaluation
02 C period for soft handovers. If this parameter is set to 0, rate
Soft reduction after soft handover failure is disabled.
Han GUI Value Range: 0~63
dov Unit: None
er Actual Value Range: 0~63
Default Value: 3
ShoFa B SET W Inte Meaning: Maximum evaluation period for rate reduction after
ilPerio S UINT RF r soft handover failure. When rate reduction evaluation is
d C RAF D- RN performed on a cell that fails to join the active set, the evaluation
6 REQ 02 C timer is started. If the cell cannot fulfill the criteria for rate
9 HO 02 Soft reduction before the timer expires, the cell will not be evaluated
0 03 Han and rate reduction re-attempt will not be initiated.
0 W dov GUI Value Range: 0~120
RF er Unit: s
D- Intr Actual Value Range: 0~120
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
02 a Default Value: 60
02 RN
02 C
Soft
Han
dov
er
ShoFa B SET W Inte Meaning: Maximum evaluation period for rate reduction after
ilPerio S UINT RF r soft handover failure. When rate reduction evaluation is
d C RAF D- RN performed on a cell that fails to join the active set, the evaluation
6 REQ 02 C timer is started. If the cell cannot fulfill the criteria for rate
9 HO 02 Soft reduction before the timer expires, the cell will not be evaluated
1 03 Han and rate reduction re-attempt will not be initiated.
0 W dov GUI Value Range: 0~120
RF er Unit: s
D- Intr Actual Value Range: 0~120
02 a
Default Value: 60
02 RN
02 C
Soft
Han
dov
er
DcccS B SET W Intr Meaning: Length of penalty timer for soft handover failure after
hoPen S UINT RF a rate reduction in the active set. When the rate reduction in the
altyTi C RAF D- RN active set is performed and the re-attempt for adding the cell to
me 6 REQ 02 C the active set is initiated, the RNC starts the penalty timer for
9 HO 02 Soft soft handover failure if the target cell fails to join the active
0 02 Han again. Before the timer expires, rate increase in the active set is
0 dov prohibited but rate reduction is not prohibited. The penalty
er policy is applied in the following scenario: A cell, which has
high signal strength and heavy traffic load, cannot be added to
the active set. This cell enters the soft handover rate reduction
evaluation process repeatedly, which results in rate reduction in
the active set. If the cell fails to be added to the active set, the
rate in the active set increases during the evaluation process
because of the DCCC algorithm. To avoid such rate fluctuation,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
the RNC uses the mechanism of rate increase penalty after soft
handover rate reduction fails again.
GUI Value Range: 0~255
Unit: s
Actual Value Range: 0~255
Default Value: 30
DcccS B SET W Intr Meaning: Length of penalty timer for soft handover failure after
hoPen S UINT RF a rate reduction in the active set. When the rate reduction in the
altyTi C RAF D- RN active set is performed and the re-attempt for adding the cell to
me 6 REQ 02 C the active set is initiated, the RNC starts the penalty timer for
9 HO 02 Soft soft handover failure if the target cell fails to join the active
1 02 Han again. Before the timer expires, rate increase in the active set is
0 dov prohibited but rate reduction is not prohibited. The penalty
er policy is applied in the following scenario: A cell, which has
high signal strength and heavy traffic load, cannot be added to
the active set. This cell enters the soft handover rate reduction
evaluation process repeatedly, which results in rate reduction in
the active set. If the cell fails to be added to the active set, the
rate in the active set increases during the evaluation process
because of the DCCC algorithm. To avoid such rate fluctuation,
the RNC uses the mechanism of rate increase penalty after soft
handover rate reduction fails again.
GUI Value Range: 0~255
Unit: s
Actual Value Range: 0~255
Default Value: 30
02 DC BE_4A_THD_ADJ_FOR_FACH_CONG_SWITCH: Whether to
14 H, activate the algorithm for setting event 4A threshold for BE
W CE services. This parameter is a cell-level parameter. When this
RF LL- switch is turned on and the threshold specified in
D- PC "BeF2DHTvmThdForFACHCong" is exceeded, the RNC transits
01 H, the UEs reporting event 4A from CELL_FACH to CELL_DCH.
06 UR When this switch is turned off, the RNC uses original thresholds
11 A- in different scenarios. 4. DRA_URA_PCH_SWITCH: Whether
37 PC to preferentially transit some UEs to the URA_PCH state. This
H, switch is a cell-level switch. When this switch is turned on, the
CE RNC preferentially transits the following UEs to the URA_PCH
LL- state: UEs that are shifted to the current cell from another cell
FA through cell reselection and UEs that are about to transit from
CH) the CELL_FACH or CELL_DCH state to the CELL_PCH or
Loa URA_PCH state. 5.
d- DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH:
bas Whether the load based state transition parameters are used for
ed UEs in a cell. When this switch is set to on and the
Inte DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH under
llig the "DraSwitch2" in the "SET UCORRMALGOSWITCH"
ent command is set to on for a cell, the following load based state
Stat transition parameters are used for UEs in the cell:
e "HiLdBeD2FStateTransTimer" in the "SET
Tra UUESTATETRANSTIMER" command,
nsiti "HiLdCellDchPSInactTimer" in the "SET UPSINACTTIMER"
on command, and "HiLdBeDLF2DHTvmThd" and
"HiLdBeULF2DETvmThd" in the "SET UUESTATETRANS"
command.
GUI Value Range:
DRA_SMART_FAST_STATE_TRANS_SWITCH,
DRA_PCH_UE_SMART_P2D_SWITCH,
BE_4A_THD_ADJ_FOR_FACH_CONG_SWITCH,
DRA_URA_PCH_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH
Unit: None
Actual Value Range:
DRA_SMART_FAST_STATE_TRANS_SWITCH,
DRA_PCH_UE_SMART_P2D_SWITCH,
BE_4A_THD_ADJ_FOR_FACH_CONG_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
DRA_URA_PCH_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH
Default Value:
DRA_SMART_FAST_STATE_TRANS_SWITCH:0,DRA_PCH
_UE_SMART_P2D_SWITCH:0,BE_4A_THD_ADJ_FOR_FAC
H_CONG_SWITCH:0,DRA_URA_PCH_SWITCH:0,DRA_IN
TELL_STATE_TRANS_ON_LOAD_SWITCH:0
W LL- 4B. In addition, the updated P-CPICH Ec/N0 value is used for
RF PC decisions on coverage-based TTI selection and coverage-based
D- H, E2D for UEs with RRC connections. 3.
01 UR DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH: Whether
06 A- the initial establishing BE service of a UE is switched from
12 PC HSUPA channels to R99 channels in weak coverage areas. When
W H, this switch is turned off, the BE service of the UE is not switched
RF CE from HSUPA channels to R99 channels in weak coverage areas.
D- LL- When this switch is turned on, the BE service of the UE is
16 FA switched from HSUPA channels to R99 channels in weak
02 CH) coverage areas. Note: When the Ec/No in the RACH
14 Dyn measurement report from the UE is less than or equal to the
ami value of "EcN0ThdForBaseCoverE2D" in the "SET UFRC"
c command, the UE is in the weak coverage area. 4.
Cha DRA_BASE_COVER_BE_E2D_SWITCH: Whether BE
nnel services can be switched over from HSUPA to R99 due to
Con insufficient coverage in connected mode. When this switch is
figu turned on, BE services can be switched over from HSUPA to
rati R99 due to insufficient coverage. If the coverage recovers after
on the UE moves to the cell center and the throughput is high, the
Con BE services can be transferred to HSUPA. Note: When event
trol 6A1 is reported, the UE is in connected mode under weak
(DC coverage. 5. DRA_D2F_OVER_IUR_SWITCH: Whether to
CC) trigger D2F state transition when no CCCH is configured over
HS the Iur interface and an Iur link is established. When this switch
UP is turned off, the RNC does not trigger the D2F procedure over
A the Iur interface if no CCCH is configured over the Iur interface.
Intr When this switch is turned on, the D2F procedure is triggered
odu regardless of the existence of the CCCH over the Iur interface. 6.
ctio DRA_CSPS_0K_RATE_UP_SWITCH: Whether the PS BE
n service in the CS+PS BE combined service supports event-4A-
Pac triggered DCCC data rate increasing when its data rate is 0
kag kbit/s. ON: This switch is turned on. The PS BE service in the
e CS+PS BE combined service supports event-4A-triggered
DCCC data rate increasing when its data rate is 0 kbit/s. OFF:
Loa
This switch is turned off. The PS BE service in the CS+PS BE
d-
combined service does not support event-4A-triggered DCCC
bas
data rate increasing when its data rate is 0 kbit/s. 7.
ed
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH: Whether the
Inte
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UUESTATETRANSTIMER" command,
"HiLdCellDchPSInactTimer" in the "SET UPSINACTTIMER"
command, and "HiLdBeDLF2DHTvmThd" and
"HiLdBeULF2DETvmThd" in the "SET UUESTATETRANS"
command. 14.
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH: Whether
the coverage-based and load-based algorithm for dynamic
reconfiguration of the channel mapped to downlink signaling
radio bearers (SRBs) takes effect.When this switch is turned off,
the algorithm does not take effect. When this switch is turned on,
The algorithm takes effect. Operations of the algorithm: 1.
Access mode: The algorithm also considers coverage and loads
to determine whether the downlink SRBs can be carried on the
HS-DSCH when a UE transits from the idle, CELL_FACH,
CELL_PCH, or URA_PCH state to the CELL_DCH state during
an RRC connection setup, RAB setup, or RAB modification or
when a CELL_DCH UE experiences an incoming inter-RAT
handover or an incoming combined hard handover and SRNS
relocation. 2. Connected mode: After a UE accesses a cell, the
algorithm determines whether to deliver periodic RSCP and
Ec/N0 measurement control messages. When the RNC receives
periodic measurement reports on the RSCP and Ec/N0, the
algorithm determines whether to initiate the SRB reconfiguration
process.
GUI Value Range:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SWITCH,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWITCH,
DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH,
DRA_BASE_COVER_BE_E2D_SWITCH,
DRA_D2F_OVER_IUR_SWITCH,
DRA_CSPS_0K_RATE_UP_SWITCH,
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH,
DRA_PS_STATE_TRANS_WHEN_CS_REL_SWITCH,
DRA_BASE_COVER_E2D_DCCC_SWITCH,
DRA_WEB_FACH_DELAY_OPT_SWITCH,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Unit: None
Actual Value Range:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SWITCH,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWITCH,
DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH,
DRA_BASE_COVER_BE_E2D_SWITCH,
DRA_D2F_OVER_IUR_SWITCH,
DRA_CSPS_0K_RATE_UP_SWITCH,
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH,
DRA_PS_STATE_TRANS_WHEN_CS_REL_SWITCH,
DRA_BASE_COVER_E2D_DCCC_SWITCH,
DRA_WEB_FACH_DELAY_OPT_SWITCH,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH
Default Value:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SWITCH:0,D
RA_PCPICH_ECN0_ON_RACH_UPDATE_SWITCH:0,DRA_
BASE_COVER_BE_E2D_INITSEL_SWITCH:0,DRA_BASE_
COVER_BE_E2D_SWITCH:0,DRA_D2F_OVER_IUR_SWIT
CH:0,DRA_CSPS_0K_RATE_UP_SWITCH:1,DRA_CSPS_BO
TH_ULDL_RATE_UP_SWITCH:0,DRA_PS_STATE_TRANS_
WHEN_CS_REL_SWITCH:0,DRA_BASE_COVER_E2D_DC
CC_SWITCH:0,DRA_WEB_FACH_DELAY_OPT_SWITCH:0,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH:0,DRA_D2
P_WHEN_PS_INACT_SWITCH:0,DRA_INTELL_STATE_TR
ANS_ON_LOAD_SWITCH:0,DRA_BASE_COVER_LOAD_S
RB_H2D_SWITCH:0
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH
Unit: None
Actual Value Range:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SWITCH,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWITCH,
DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH,
DRA_BASE_COVER_BE_E2D_SWITCH,
DRA_D2F_OVER_IUR_SWITCH,
DRA_CSPS_0K_RATE_UP_SWITCH,
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH,
DRA_PS_STATE_TRANS_WHEN_CS_REL_SWITCH,
DRA_BASE_COVER_E2D_DCCC_SWITCH,
DRA_WEB_FACH_DELAY_OPT_SWITCH,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWITCH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH
Default Value:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SWITCH:0,D
RA_PCPICH_ECN0_ON_RACH_UPDATE_SWITCH:0,DRA_
BASE_COVER_BE_E2D_INITSEL_SWITCH:0,DRA_BASE_
COVER_BE_E2D_SWITCH:0,DRA_D2F_OVER_IUR_SWIT
CH:0,DRA_CSPS_0K_RATE_UP_SWITCH:1,DRA_CSPS_BO
TH_ULDL_RATE_UP_SWITCH:0,DRA_PS_STATE_TRANS_
WHEN_CS_REL_SWITCH:0,DRA_BASE_COVER_E2D_DC
CC_SWITCH:0,DRA_WEB_FACH_DELAY_OPT_SWITCH:0,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH:0,DRA_D2
P_WHEN_PS_INACT_SWITCH:0,DRA_INTELL_STATE_TR
ANS_ON_LOAD_SWITCH:0,DRA_BASE_COVER_LOAD_S
RB_H2D_SWITCH:0
IntraF B ADD W Inte Meaning: This parameter specifies the Layer 3 filter coefficient
reqFilt S UCE RF r for the intra-frequency measurement. According to 3GPP TS
erCoef C LLIN D- RN 25.331, the filtered measurement value is calculated using the
6 TRAF 02 C following formula, where k represents this parameter: Fn = (1 -
9 REQ 02 Soft a) * Fn - 1 + a * Mn a = 1/(2 ^ (k/2)) Here, Fn: filtered
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraF B ADD W Inte Meaning: This parameter specifies the Layer 3 filter coefficient
reqFilt S UCE RF r for the intra-frequency measurement. According to 3GPP TS
erCoef C LLIN D- RN 25.331, the filtered measurement value is calculated using the
6 TRAF 02 C following formula, where k represents this parameter: Fn = (1 -
9 REQ 02 Soft a) * Fn - 1 + a * Mn a = 1/(2 ^ (k/2)) Here, Fn: filtered
1 HO 03 Han measurement result Fn - 1: previously filtered measurement
0 MOD W dov result Mn: latest received measurement result from physical
UCE RF er layer When a is set to 1, L3 filtering is not applied. The input
LLIN D- Intr measurement value to L3 filter has been filtered by L1 filter,
TRAF 02 a where the impact of fast fading is almost eliminated. In this case,
REQ 02 RN smooth filtering should be applied through L3 filter, to eliminate
HO 02 C the effect of shadow fading and peaks caused by fast fading, thus
Soft the filtered measurement value can reflect the variation of the
Han actual measurement value, and provide more reliable
dov measurement result for event judgement. Note that this
er parameter has great impact on the overall performance of the
handover. Therefore, set this parameter with caution.
GUI Value Range: D0, D1, D2, D3, D4, D5, D6, D7, D8, D9,
D11, D13, D15, D17, D19
Unit: None
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RsvU B SET No Non Meaning: RRM algorithm reserved U32 para 8. The 32-bit
32Par S UAL ne e parameter is reserved for further change request use. Disuse
a8 C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
0 parameter is not recommended for the configuration interface.
0 GUI Value Range: 0~4294967295
Unit: None
Actual Value Range: 0~4294967295
Default Value: 0
RsvU B SET No Non Meaning: RRM algorithm reserved U32 para 8. The 32-bit
32Par S UAL ne e parameter is reserved for further change request use. Disuse
a8 C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
1 parameter is not recommended for the configuration interface.
0 GUI Value Range: 0~4294967295
Unit: None
Actual Value Range: 0~4294967295
Default Value: 0
er
Bas
ed
on
Cov
erag
e
ect
Retr
y
InterR B ADD W Inte Meaning: Interval that the UE reports inter-RAT measurement
ATPer S UCE RF r- results to the RNC. This parameter specifies the interval that the
iodRe C LLIN D- RA UE sends inter-RAT measurement results to the RNC in
portInt 6 TERR 02 T periodical reporting mode. It is not recommended that this
erval 9 ATH 03 Han parameter is set to NON_PERIODIC_REPORT since the UE
0 OCO 09 dov behavior may be unknown. The GSM RSSI measurement period
0 V W er is 480 ms. Therefore, the inter-RAT periodical reporting interval
MOD RF Bas should be longer than 480 ms. If the periodical reporting interval
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UCE D- ed is excessively high, the handover decision time will be long, and
LLIN 02 on handovers will be slow. The adjustment should be made
TERR 03 DL according to the configured GSM RSSI measurement
ATH 03 Qo compressed mode sequence. According to the current configured
OCO W S GSM RSSI measurement compressed mode sequence, the RSSI
V RF Inte measurement of eight GSM cells can be finished in 480 ms.
D- r- Therefore, the RSSI measurement of 16 GSM cells can be
02 RA finished in 1000 ms. According to 3GPP specifications, the
04 T number of inter-RAT neighboring cells should not exceed 32.
02 Han Therefore, the parameter value can be set to 2000 ms if the
dov number of neighboring GSM cells exceeds 16.
er GUI Value Range: NON_PERIODIC_REPORT(Non periodical
Bas reporting), D250(D250), D500(D500), D1000(D1000),
ed D2000(D2000), D3000(D3000), D4000(D4000),
on D6000(D6000), D8000(D8000), D12000(D12000),
Cov D16000(D16000), D20000(D20000), D24000(D24000),
erag D28000(D28000), D32000(D32000), D64000(D64000)
e Unit: ms
Me Actual Value Range: NON_PERIODIC_REPORT, 250, 500,
asur 1000, 2000, 3000, 4000, 6000, 8000, 12000, 16000, 20000,
eme 24000, 28000, 32000, 64000
nt Default Value: D1000(D1000)
Bas
ed
Dir
ect
Retr
y
InterR B ADD W Inte Meaning: Interval that the UE reports inter-RAT measurement
ATPer S UCE RF r- results to the RNC. This parameter specifies the interval that the
iodRe C LLIN D- RA UE sends inter-RAT measurement results to the RNC in
portInt 6 TERR 02 T periodical reporting mode. It is not recommended that this
erval 9 ATH 03 Han parameter is set to NON_PERIODIC_REPORT since the UE
1 OCO 09 dov behavior may be unknown. The GSM RSSI measurement period
0 V W er is 480 ms. Therefore, the inter-RAT periodical reporting interval
MOD RF Bas should be longer than 480 ms. If the periodical reporting interval
UCE D- ed is excessively high, the handover decision time will be long, and
LLIN 02 on handovers will be slow. The adjustment should be made
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UsedF B ADD W Inte Meaning: This parameter configures the used frequency
reqMe S UCE RF r- measurement quantity to trigger the inter-RAT measurement for
asQua C LLQ D- RA the purpose of QoS-based handover. The parameter is valid when
ntityF 6 OSH 02 T the event reporting mode is selected for inter-RAT. Ec/No:
orQos 9 O 03 Han signal-to-noise ratio RSCP: received signal code power
3A 0 MOD 09 dov CPICH_Ec/NO: the measurement quantity used for event 2D and
0 UCE er 2F, with unit of dB CPICH_RSCP: the measurement quantity
LLQ Bas used for event 2D and 2F, with unit of dBm The RNC, in the
OSH ed coverage-based inter-RAT measurement, may configure that the
O on inter-RAT measurement quantity are delivered according to
DL event 2D that triggers the measurement, which causes the result
Qo that the QoS-based inter-RAT measurement cannot refer to the
S coverage-based configurations. Under this condition, it is
necessary for the QoS-based inter-RAT measurement to set the
used frequency separately. When both the QoS-based and the
coverage-based inter-RAT measurements exist, refer to this
parameter. As for the impact on network performance: When the
UE moves to the cell border, and there is a intra-frequency
neighboring cell in the moving direction, CPCICH Ec/No varies
faster than RSCP and the quality of the current cell should be
evaluated according to CPCICH Ec/No. When there is no intra-
frequency neighboring cell in the direction, CPCICH RSCP
varies faster than Ec/No and the quality should be evaluated
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UsedF B ADD W Inte Meaning: This parameter configures the used frequency
reqMe S UCE RF r- measurement quantity to trigger the inter-RAT measurement for
asQua C LLQ D- RA the purpose of QoS-based handover. The parameter is valid when
ntityF 6 OSH 02 T the event reporting mode is selected for inter-RAT. Ec/No:
orQos 9 O 03 Han signal-to-noise ratio RSCP: received signal code power
3A 1 MOD 09 dov CPICH_Ec/NO: the measurement quantity used for event 2D and
0 UCE er 2F, with unit of dB CPICH_RSCP: the measurement quantity
LLQ Bas used for event 2D and 2F, with unit of dBm The RNC, in the
OSH ed coverage-based inter-RAT measurement, may configure that the
O on inter-RAT measurement quantity are delivered according to
DL event 2D that triggers the measurement, which causes the result
Qo that the QoS-based inter-RAT measurement cannot refer to the
S coverage-based configurations. Under this condition, it is
necessary for the QoS-based inter-RAT measurement to set the
used frequency separately. When both the QoS-based and the
coverage-based inter-RAT measurements exist, refer to this
parameter. As for the impact on network performance: When the
UE moves to the cell border, and there is a intra-frequency
neighboring cell in the moving direction, CPCICH Ec/No varies
faster than RSCP and the quality of the current cell should be
evaluated according to CPCICH Ec/No. When there is no intra-
frequency neighboring cell in the direction, CPCICH RSCP
varies faster than Ec/No and the quality should be evaluated
according to CPCICH RSCP. If the measurement quantity is not
properly selected, the handover may not be performed timely,
thus resulting in call drops.
GUI Value Range: CPICH_EC/NO, CPICH_RSCP
Unit: None
Actual Value Range: CPICH_EC/NO, CPICH_RSCP
Default Value: CPICH_RSCP
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TimeT B ADD W Inte Meaning: Time delay to trigger event 2D. A UE reports an event
oTrig2 S UCE RF r 2D measurement report if the conditions for triggering event 2D
D C LLIN D- Fre are met and persist during the time period specified by this
6 TERF 02 que parameter.
9 REQ 03 ncy GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
0 HOC 02 Har D160, D200, D240, D320, D640, D1280, D2560, D5000
0 OV d Unit: ms
MOD Han
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
UCE dov
240, 320, 640, 1280, 2560, 5000
LLIN er
Bas Default Value: D320
TERF
REQ ed
HOC on
OV Cov
erag
e
TimeT B ADD W Inte Meaning: Time delay to trigger event 2D. A UE reports an event
oTrig2 S UCE RF r 2D measurement report if the conditions for triggering event 2D
D C LLIN D- Fre are met and persist during the time period specified by this
6 TERF 02 que parameter.
9 REQ 03 ncy GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
1 HOC 02 Har D160, D200, D240, D320, D640, D1280, D2560, D5000
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
0 OV d Unit: ms
MOD Han Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
UCE dov 240, 320, 640, 1280, 2560, 5000
LLIN er Default Value: D320
TERF Bas
REQ ed
HOC on
OV Cov
erag
e
HystF B ADD W Inte Meaning: Hysteresis for triggering event 2D. When
or2D S UCE RF r "InterFreqReportMode" is set to PERIODICAL_REPORTING,
C LLIN D- Fre the hysteresis in active set quality measurement is used to
6 TERF 02 que prevent the ping-pong reporting of event 2D (triggered when the
9 REQ 03 ncy estimated quality of the frequency in use is lower than the
0 HOC 02 Har threshold) and event 2F (triggered when the estimated quality of
0 OV d the frequency in use is higher than the threshold). Event 2D is
MOD Han used to enable the compression mode and event 2F is used to
UCE dov disable the compression mode.To prevent the compression mode
LLIN er from being frequently enabled and disabled, you can set
TERF Bas "Hystfor2D" and "Hystfor2F" to be greater than their
REQ ed recommended values according to the statistics of the ping-pong
HOC on inter-frequency handover.
OV Cov GUI Value Range: 0~29
erag Unit: 0.5dB; 0.5dBm
e
Actual Value Range: 0~14.5
Default Value: 4
HystF B ADD W Inte Meaning: Hysteresis for triggering event 2D. When
or2D S UCE RF r "InterFreqReportMode" is set to PERIODICAL_REPORTING,
C LLIN D- Fre the hysteresis in active set quality measurement is used to
6 TERF 02 que prevent the ping-pong reporting of event 2D (triggered when the
9 REQ 03 ncy estimated quality of the frequency in use is lower than the
1 HOC 02 Har threshold) and event 2F (triggered when the estimated quality of
0 OV d the frequency in use is higher than the threshold). Event 2D is
MOD Han used to enable the compression mode and event 2F is used to
UCE dov disable the compression mode.To prevent the compression mode
LLIN er from being frequently enabled and disabled, you can set
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Hystfo B ADD W Inte Meaning: Hysteresis for event 2D. The hysteresis can be
r2D S UCE RF r- evaluated based on the Ec/N0 or RSCP. For details about this
C LLIN D- RA parameter, see 3GPP TS 25.331.
6 TERR 02 T GUI Value Range: 0~29
9 ATH 03 Han Unit: 0.5dB; 0.5dBm
0 OCO 03 dov
Actual Value Range: 0~14.5
0 V er
Bas Default Value: 4
MOD
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
Hystfo B ADD W Inte Meaning: Hysteresis for event 2D. The hysteresis can be
r2D S UCE RF r- evaluated based on the Ec/N0 or RSCP. For details about this
C LLIN D- RA parameter, see 3GPP TS 25.331.
6 TERR 02 T GUI Value Range: 0~29
9 ATH 03 Han Unit: 0.5dB; 0.5dBm
1 OCO 03 dov
Actual Value Range: 0~14.5
0 V er
Bas Default Value: 4
MOD
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
V Unit: dB
Actual Value Range: -24~0
Default Value: -15
SCP 9 ATH 03 Han signaling to enable the compressed mode and start inter-RAT
1 OCO 03 dov measurements. Event 2D and event 2F are used to enable and
0 V er disable the compressed mode respectively. To enable the
MOD Bas compressed mode earlier, increase the threshold of triggering
UCE ed event 2D; otherwise, decrease the threshold of triggering event
LLIN on 2D. To prevent the frequent enabling and disabling of the
TERR Cov compressed mode, increase the difference between the thresholds
ATH erag of triggering event 2D and event 2F.
OCO e GUI Value Range: -115~-25
V Unit: dBm
Actual Value Range: -115~-25
Default Value: -110
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
TimeT B ADD W Inte Meaning: Time delay to trigger event 2F. A UE reports an event
oTrig2 S UCE RF r 2F measurement report if the conditions for triggering event 2F
F C LLIN D- Fre are met and persist during the time period specified by this
6 TERF 02 que parameter.
9 REQ 03 ncy GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
0 HOC 02 Har D160, D200, D240, D320, D640, D1280, D2560, D5000
0 OV d Unit: ms
MOD Han
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
UCE dov
240, 320, 640, 1280, 2560, 5000
LLIN er
Bas Default Value: D1280
TERF
REQ ed
HOC on
OV Cov
erag
e
TimeT B ADD W Inte Meaning: Time delay to trigger event 2F. A UE reports an event
oTrig2 S UCE RF r 2F measurement report if the conditions for triggering event 2F
F C LLIN D- Fre are met and persist during the time period specified by this
6 TERF 02 que parameter.
9 REQ 03 ncy GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
1 HOC 02 Har D160, D200, D240, D320, D640, D1280, D2560, D5000
0 OV d Unit: ms
MOD Han
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
UCE dov
240, 320, 640, 1280, 2560, 5000
LLIN er
Default Value: D1280
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TERF Bas
REQ ed
HOC on
OV Cov
erag
e
HystF B ADD W Inte Meaning: Hysteresis for triggering event 2F. When
or2F S UCE RF r "InterFreqReportMode" is set to PERIODICAL_REPORTING,
C LLIN D- Fre the hysteresis in active set quality measurement is used to
6 TERF 02 que prevent the ping-pong reporting of event 2D (triggered when the
9 REQ 03 ncy estimated quality of the frequency in use is lower than the
0 HOC 02 Har threshold) and event 2F (triggered when the estimated quality of
0 OV d the frequency in use is higher than the threshold). Event 2D is
MOD Han used to enable the compression mode and event 2F is used to
UCE dov disable the compression mode.To prevent the compression mode
LLIN er from being frequently enabled and disabled, you can set
TERF Bas "Hystfor2D" and "Hystfor2F" to be greater than their
REQ ed recommended values according to the statistics of the ping-pong
HOC on inter-frequency handover.
OV Cov GUI Value Range: 0~29
erag Unit: 0.5dB; 0.5dBm
e
Actual Value Range: 0~14.5
Default Value: 4
HystF B ADD W Inte Meaning: Hysteresis for triggering event 2F. When
or2F S UCE RF r "InterFreqReportMode" is set to PERIODICAL_REPORTING,
C LLIN D- Fre the hysteresis in active set quality measurement is used to
6 TERF 02 que prevent the ping-pong reporting of event 2D (triggered when the
9 REQ 03 ncy estimated quality of the frequency in use is lower than the
1 HOC 02 Har threshold) and event 2F (triggered when the estimated quality of
0 OV d the frequency in use is higher than the threshold). Event 2D is
MOD Han used to enable the compression mode and event 2F is used to
UCE dov disable the compression mode.To prevent the compression mode
LLIN er from being frequently enabled and disabled, you can set
TERF Bas "Hystfor2D" and "Hystfor2F" to be greater than their
REQ ed recommended values according to the statistics of the ping-pong
HOC on inter-frequency handover.
OV Cov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Hystfo B ADD W Inte Meaning: Hysteresis for event 2F. The hysteresis can be
r2F S UCE RF r- evaluated based on the Ec/N0 or RSCP. For details about this
C LLIN D- RA parameter, see 3GPP TS 25.331.
6 TERR 02 T
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Hystfo B ADD W Inte Meaning: Hysteresis for event 2F. The hysteresis can be
r2F S UCE RF r- evaluated based on the Ec/N0 or RSCP. For details about this
C LLIN D- RA parameter, see 3GPP TS 25.331.
6 TERR 02 T GUI Value Range: 0~29
9 ATH 03 Han Unit: 0.5dB; 0.5dBm
1 OCO 03 dov
Actual Value Range: 0~14.5
0 V er
Bas Default Value: 4
MOD
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
V Unit: dB
Actual Value Range: -24~0
Default Value: -12
9 ATH 03 Han disable the compressed mode and stop inter-RAT measurements.
1 OCO 03 dov Event 2D and event 2F are used to enable and disable the
0 V er compressed mode respectively. To disable the compressed mode
MOD Bas earlier, reduce the threshold of triggering event 2F; otherwise,
UCE ed increase the threshold of triggering event 2F. To prevent the
LLIN on frequent enabling and disabling of the compressed mode,
TERR Cov increase the difference between the thresholds of triggering event
ATH erag 2D and event 2F.
OCO e GUI Value Range: -24~0
V Unit: dB
Actual Value Range: -24~0
Default Value: -13
ULTI 03 Bas increase the difference between the event 2D threshold and event
RAB 03 ed 2F threshold.
HOC on GUI Value Range: -24~0
OV Cov Unit: dB
erag
Actual Value Range: -24~0
e
Default Value: -12
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
T
Han
dov
er
Bas
ed
on
Cov
erag
e
TimeT B ADD W Inte Meaning: Time delay to trigger event 2B. A UE reports an event
oTrig2 S UCE RF r 2B measurement report if the conditions for triggering event 2B
B C LLIN D- Fre are met and persist during the time period specified by this
6 TERF 02 que parameter.
9 REQ 03 ncy GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
0 HOC 02 Har D160, D200, D240, D320, D640, D1280, D2560, D5000
0 OV W d Unit: ms
MOD RF Han
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
UCE D- dov
240, 320, 640, 1280, 2560, 5000
LLIN 02 er
Bas Default Value: D0
TERF 03
REQ 04 ed
HOC on
OV Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
TimeT B ADD W Inte Meaning: Time delay to trigger event 2B. A UE reports an event
oTrig2 S UCE RF r 2B measurement report if the conditions for triggering event 2B
B C LLIN D- Fre are met and persist during the time period specified by this
6 TERF 02 que parameter.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
9 REQ 03 ncy GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
1 HOC 02 Har D160, D200, D240, D320, D640, D1280, D2560, D5000
0 OV W d Unit: ms
MOD RF Han Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
UCE D- dov 240, 320, 640, 1280, 2560, 5000
LLIN 02 er
Default Value: D0
TERF 03 Bas
REQ 04 ed
HOC on
OV Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
HystF B ADD W Inte Meaning: Event 2B hysteresis. The hysteresis can be the Ec/No
or2B S UCE RF r or RSCP. For details, see 3GPP TS 25.331.
C LLIN D- Fre GUI Value Range: 0~29
6 TERF 02 que Unit: 0.5dB; 0.5dBm
9 REQ 03 ncy
Actual Value Range: 0~14.5
0 HOC 02 Har
0 OV d Default Value: 4
MOD Han
UCE dov
LLIN er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TERF Bas
REQ ed
HOC on
OV Cov
erag
e
HystF B ADD W Inte Meaning: Event 2B hysteresis. The hysteresis can be the Ec/No
or2B S UCE RF r or RSCP. For details, see 3GPP TS 25.331.
C LLIN D- Fre GUI Value Range: 0~29
6 TERF 02 que Unit: 0.5dB; 0.5dBm
9 REQ 03 ncy
Actual Value Range: 0~14.5
1 HOC 02 Har
0 OV d Default Value: 4
MOD Han
UCE dov
LLIN er
TERF Bas
REQ ed
HOC on
OV Cov
erag
e
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqC S UCE RF r frequency measurement based on measurement quantity of
sThdE C LLIN D- Fre Ec/No for CS services. For CS services, if the inter-frequency
cN0 6 TERF 02 que reporting mode is set to "EVENT_TRIGGER", this parameter is
9 REQ 03 ncy used to set the criterion for triggering event 2B. That is, event 2B
0 HOC 02 Har can be triggered when the quality of the target frequency is
0 OV d higher than this threshold. If the inter-frequency reporting mode
MOD Han is set to "PERIODIC_TRIGGER", this parameter is used for
UCE dov handover decision.
LLIN er GUI Value Range: -24~0
TERF Bas Unit: dB
REQ ed
Actual Value Range: -24~0
HOC on
Cov Default Value: -12
OV
erag
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqC S UCE RF r frequency measurement based on measurement quantity of
sThdE C LLIN D- Fre Ec/No for CS services. For CS services, if the inter-frequency
cN0 6 TERF 02 que reporting mode is set to "EVENT_TRIGGER", this parameter is
9 REQ 03 ncy used to set the criterion for triggering event 2B. That is, event 2B
1 HOC 02 Har can be triggered when the quality of the target frequency is
0 OV d higher than this threshold. If the inter-frequency reporting mode
MOD Han is set to "PERIODIC_TRIGGER", this parameter is used for
UCE dov handover decision.
LLIN er GUI Value Range: -24~0
TERF Bas Unit: dB
REQ ed
Actual Value Range: -24~0
HOC on
Cov Default Value: -12
OV
erag
e
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqC S UCE RF r frequency measurement based on measurement quantity of
sThdR C LLIN D- Fre RSCP for CS services. For CS services, if the inter-frequency
scp 6 TERF 02 que reporting mode is set to "EVENT_TRIGGER", this parameter is
9 REQ 03 ncy used to set the criterion for triggering event 2B. That is, event 2B
0 HOC 02 Har can be triggered when the quality of the target frequency is
0 OV d higher than this threshold. If the inter-frequency reporting mode
MOD Han is set to "PERIODIC_TRIGGER", this parameter is used for
UCE dov handover decision.
LLIN er GUI Value Range: -115~-25
TERF Bas Unit: dBm
REQ ed
Actual Value Range: -115~-25
HOC on
Cov Default Value: -92
OV
erag
e
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqC S UCE RF r frequency measurement based on measurement quantity of
sThdR C LLIN D- Fre RSCP for CS services. For CS services, if the inter-frequency
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqR S UCE RF r frequency measurement based on measurement quantity of
99PsT C LLIN D- Fre Ec/No for non-HSPA services in PS domain.For non-HSPA
hdEc 6 TERF 02 que services in PS domain, if the inter-frequency reporting mode is
N0 9 REQ 03 ncy set to "EVENT_TRIGGER", this parameter is used to set the
0 HOC 02 Har criterion for triggering event 2B. That is, event 2B can be
0 OV d triggered when the quality of the target frequency is higher than
MOD Han this threshold. If the inter-frequency reporting mode is set to
UCE dov "PERIODIC_TRIGGER", this parameter is used for handover
LLIN er decision.
TERF Bas GUI Value Range: -24~0
REQ ed Unit: dB
HOC on
Actual Value Range: -24~0
OV Cov
erag Default Value: -12
e
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqR S UCE RF r frequency measurement based on measurement quantity of
99PsT C LLIN D- Fre Ec/No for non-HSPA services in PS domain.For non-HSPA
hdEc 6 TERF 02 que services in PS domain, if the inter-frequency reporting mode is
N0 9 REQ 03 ncy set to "EVENT_TRIGGER", this parameter is used to set the
1 HOC 02 Har criterion for triggering event 2B. That is, event 2B can be
0 OV d triggered when the quality of the target frequency is higher than
MOD Han this threshold. If the inter-frequency reporting mode is set to
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqR S UCE RF r frequency measurement based on measurement quantity of
99PsT C LLIN D- Fre RSCP for non-HSPA services in PS domain.For non-HSPA
hdRsc 6 TERF 02 que services in PS domain, if the inter-frequency reporting mode is
p 9 REQ 03 ncy set to "EVENT_TRIGGER", this parameter is used to set the
0 HOC 02 Har criterion for triggering event 2B. That is, event 2B can be
0 OV d triggered when the quality of the target frequency is higher than
MOD Han this threshold. If the inter-frequency reporting mode is set to
UCE dov "PERIODIC_TRIGGER", this parameter is used for handover
LLIN er decision.
TERF Bas GUI Value Range: -115~-25
REQ ed Unit: dBm
HOC on
Actual Value Range: -115~-25
OV Cov
erag Default Value: -92
e
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqR S UCE RF r frequency measurement based on measurement quantity of
99PsT C LLIN D- Fre RSCP for non-HSPA services in PS domain.For non-HSPA
hdRsc 6 TERF 02 que services in PS domain, if the inter-frequency reporting mode is
p 9 REQ 03 ncy set to "EVENT_TRIGGER", this parameter is used to set the
1 HOC 02 Har criterion for triggering event 2B. That is, event 2B can be
0 OV d triggered when the quality of the target frequency is higher than
MOD Han this threshold. If the inter-frequency reporting mode is set to
UCE dov "PERIODIC_TRIGGER", this parameter is used for handover
LLIN er decision.
TERF Bas GUI Value Range: -115~-25
REQ ed Unit: dBm
HOC on
Actual Value Range: -115~-25
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqH S UCE RF r frequency measurement based on measurement quantity of
ThdEc C LLIN D- Fre Ec/No for HSPA services.For HSPA services, if the inter-
N0 6 TERF 02 que frequency reporting mode is set to "EVENT_TRIGGER", this
9 REQ 03 ncy parameter is used to set the criterion for triggering event 2B.
0 HOC 02 Har That is, event 2B can be triggered when the quality of the target
0 OV d frequency is higher than this threshold. If the inter-frequency
MOD Han reporting mode is set to "PERIODIC_TRIGGER", this parameter
UCE dov is used for handover decision.
LLIN er GUI Value Range: -24~0
TERF Bas Unit: dB
REQ ed
Actual Value Range: -24~0
HOC on
Cov Default Value: -12
OV
erag
e
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqH S UCE RF r frequency measurement based on measurement quantity of
ThdEc C LLIN D- Fre Ec/No for HSPA services.For HSPA services, if the inter-
N0 6 TERF 02 que frequency reporting mode is set to "EVENT_TRIGGER", this
9 REQ 03 ncy parameter is used to set the criterion for triggering event 2B.
1 HOC 02 Har That is, event 2B can be triggered when the quality of the target
0 OV d frequency is higher than this threshold. If the inter-frequency
MOD Han reporting mode is set to "PERIODIC_TRIGGER", this parameter
UCE dov is used for handover decision.
LLIN er GUI Value Range: -24~0
TERF Bas Unit: dB
REQ ed
Actual Value Range: -24~0
HOC on
Cov Default Value: -12
OV
erag
e
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Threshold of the target frequency for triggering inter-
FreqH S UCE RF r frequency measurement based on measurement quantity of
ThdRs C LLIN D- Fre RSCP for HSPA services. For HSPA services, if the inter-
cp 6 TERF 02 que frequency reporting mode is set to "EVENT_TRIGGER", this
9 REQ 03 ncy parameter is used to set the criterion for triggering event 2B.
1 HOC 02 Har That is, event 2B can be triggered when the quality of the target
0 OV d frequency is higher than this threshold. If the inter-frequency
MOD Han reporting mode is set to "PERIODIC_TRIGGER", this parameter
UCE dov is used for handover decision. After handover, to prevent ping-
LLIN er pong handover, the inter-frequency measurement should not be
TERF Bas started again. That is, this parameter is usually set greater than
REQ ed the start threshold for event 2D or equal to the threshold of event
HOC on 2F.
OV Cov GUI Value Range: -115~-25
erag Unit: dBm
e
Actual Value Range: -115~-25
Default Value: -92
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqCS S UCE RF r RSCP-based measurement for CS services. When RSCP is used
ThdR C LLIN D- Fre as the measurement quantity for CS services, one of the
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
SCP 6 TERF 02 que necessary conditions for triggering event 2B can be met only
9 REQ 03 ncy when the quality of the used frequency is lower than the value of
0 HOC 02 Har this parameter. Event 2B is triggered only when both the
0 OV d necessary conditions are met.
MOD Han GUI Value Range: -115~-25
UCE dov Unit: dBm
LLIN er
Actual Value Range: -115~-25
TERF Bas
REQ ed Default Value: -92
HOC on
OV Cov
erag
e
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqCS S UCE RF r RSCP-based measurement for CS services. When RSCP is used
ThdR C LLIN D- Fre as the measurement quantity for CS services, one of the
SCP 6 TERF 02 que necessary conditions for triggering event 2B can be met only
9 REQ 03 ncy when the quality of the used frequency is lower than the value of
1 HOC 02 Har this parameter. Event 2B is triggered only when both the
0 OV d necessary conditions are met.
MOD Han GUI Value Range: -115~-25
UCE dov Unit: dBm
LLIN er
Actual Value Range: -115~-25
TERF Bas
ed Default Value: -92
REQ
HOC on
OV Cov
erag
e
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqR9 S UCE RF r RSCP-based measurement for PS non-HSPA services. When
9PsTh C LLIN D- Fre RSCP is used as the measurement quantity for PS non-HSPA
dRSC 6 TERF 02 que services, one of the necessary conditions for triggering event 2B
P 9 REQ 03 ncy can be met only when the quality of the used frequency is lower
0 HOC 02 Har than the value of this parameter. Event 2B is triggered only when
0 OV d both the necessary conditions are met.
MOD Han GUI Value Range: -115~-25
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqR9 S UCE RF r RSCP-based measurement for PS non-HSPA services. When
9PsTh C LLIN D- Fre RSCP is used as the measurement quantity for PS non-HSPA
dRSC 6 TERF 02 que services, one of the necessary conditions for triggering event 2B
P 9 REQ 03 ncy can be met only when the quality of the used frequency is lower
1 HOC 02 Har than the value of this parameter. Event 2B is triggered only when
0 OV d both the necessary conditions are met.
MOD Han GUI Value Range: -115~-25
UCE dov Unit: dBm
LLIN er
Actual Value Range: -115~-25
TERF Bas
ed Default Value: -92
REQ
HOC on
OV Cov
erag
e
UsedF B ADD W Inte Meaning: The larger the value of this parameter, the more
reqHT S UCE RF r difficult it will be to trigger event 2B and inter-frequency
hdRS C LLIN D- Fre handovers, and the more easily call drops occur due to delayed
CP 6 TERF 02 que handovers. The smaller the value of this parameter, the easier it
9 REQ 03 ncy will be to trigger event 2B. If this parameter is set to a very small
0 HOC 02 Har value, the handover success rate decreases. In most cases, this
0 OV d value of this parameter should be smaller than the threshold for
MOD Han triggering event 2F or should be equal to the threshold for
UCE dov triggering event 2D.
LLIN er GUI Value Range: -115~-25
TERF Bas Unit: dBm
REQ ed
Actual Value Range: -115~-25
HOC on
Default Value: -92
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
OV Cov
erag
e
UsedF B ADD W Inte Meaning: The larger the value of this parameter, the more
reqHT S UCE RF r difficult it will be to trigger event 2B and inter-frequency
hdRS C LLIN D- Fre handovers, and the more easily call drops occur due to delayed
CP 6 TERF 02 que handovers. The smaller the value of this parameter, the easier it
9 REQ 03 ncy will be to trigger event 2B. If this parameter is set to a very small
1 HOC 02 Har value, the handover success rate decreases. In most cases, this
0 OV d value of this parameter should be smaller than the threshold for
MOD Han triggering event 2F or should be equal to the threshold for
UCE dov triggering event 2D.
LLIN er GUI Value Range: -115~-25
TERF Bas Unit: dBm
REQ ed
Actual Value Range: -115~-25
HOC on
Cov Default Value: -92
OV
erag
e
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqCS S UCE RF r Ec/No-based measurement for CS services. When Ec/No is used
ThdEc C LLIN D- Fre as the measurement quantity for CS services, one of the
N0 6 TERF 02 que necessary conditions for triggering event 2B can be met only
9 REQ 03 ncy when the quality of the used frequency is lower than the value of
0 HOC 02 Har this parameter. Event 2B is triggered only when both the
0 OV d necessary conditions are met.
MOD Han GUI Value Range: -24~0
UCE dov Unit: dB
LLIN er
Actual Value Range: -24~0
TERF Bas
ed Default Value: -12
REQ
HOC on
OV Cov
erag
e
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqR9 S UCE RF r Ec/No-based measurement for PS non-HSPA services. When
9PsTh C LLIN D- Fre Ec/No is used as the measurement quantity for PS non-HSPA
dEcN 6 TERF 02 que services, one of the necessary conditions for triggering event 2B
0 9 REQ 03 ncy can be met only when the quality of the used frequency is lower
0 HOC 02 Har than the value of this parameter. Event 2B is triggered only when
0 OV d both the necessary conditions are met.
MOD Han GUI Value Range: -24~0
UCE dov Unit: dB
LLIN er
Actual Value Range: -24~0
TERF Bas
ed Default Value: -12
REQ
HOC on
OV Cov
erag
e
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqR9 S UCE RF r Ec/No-based measurement for PS non-HSPA services. When
9PsTh C LLIN D- Fre Ec/No is used as the measurement quantity for PS non-HSPA
dEcN 6 TERF 02 que services, one of the necessary conditions for triggering event 2B
0 9 REQ 03 ncy can be met only when the quality of the used frequency is lower
1 HOC 02 Har than the value of this parameter. Event 2B is triggered only when
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqHT S UCE RF r Ec/No-based measurement for HSPA services. When Ec/No is
hdEc C LLIN D- Fre used as the measurement quantity for HSPA services, one of the
N0 6 TERF 02 que necessary conditions for triggering event 2B can be met only
9 REQ 03 ncy when the quality of the used frequency is lower than the value of
0 HOC 02 Har this parameter. Event 2B is triggered only when both the
0 OV d necessary conditions are met.
MOD Han GUI Value Range: -24~0
UCE dov Unit: dB
LLIN er
Actual Value Range: -24~0
TERF Bas
ed Default Value: -12
REQ
HOC on
OV Cov
erag
e
UsedF B ADD W Inte Meaning: Threshold of used frequency quality for triggering
reqHT S UCE RF r Ec/No-based measurement for HSPA services. When Ec/No is
hdEc C LLIN D- Fre used as the measurement quantity for HSPA services, one of the
N0 6 TERF 02 que necessary conditions for triggering event 2B can be met only
9 REQ 03 ncy when the quality of the used frequency is lower than the value of
1 HOC 02 Har this parameter. Event 2B is triggered only when both the
0 OV d necessary conditions are met.
MOD Han GUI Value Range: -24~0
UCE dov Unit: dB
LLIN er
Actual Value Range: -24~0
TERF Bas
Default Value: -12
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
REQ ed
HOC on
OV Cov
erag
e
RABT 6 ULTI 02 que when both of the following conditions are met: -The event-
hdEc 9 RAB 03 ncy triggered reporting mode is used for inter-frequency
No 1 HOC 02 Har measurement, and signal quality in the cell that operates at the
0 OV W d target frequency is higher than this threshold. -The criterion for
MOD RF Han UsedFreqCSPSThdEcN0 is fulfilled. If the periodic reporting
UCE D- dov mode is used for inter-frequency measurement, the RNC makes a
LLM 02 er handover decision based on this threshold.
ULTI 03 Bas GUI Value Range: -24~0
RAB 03 ed Unit: dB
HOC on
Actual Value Range: -24~0
OV Cov
erag Default Value: -12
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
dov
er
Bas
ed
on
Cov
erag
e
DlRsc B ADD W Inte Meaning: Frequency hysteresis of downlink RSCP QoS. This
pQos S UCE RF r- parameter controls the used frequency thresholds for the inter-
Hyst C LLQ D- RA frequency and inter-RAT measurement based on QoS. In event
6 OSH 02 T mode, if the inter-frequency and inter-RAT measurement events
9 O 03 Han occurred for the downlink QoS reason, the used frequency
0 MOD 09 dov threshold of the RSCP measurement quantity is equal to the used
0 UCE W er frequency threshold that is configured on the OMU server in
LLQ RF Bas coverage measurement plus this parameter. As for the impact on
OSH D- ed network performance: The larger the value of the parameter is,
O 02 on the more easily event 2B, inter-frequency handover based on
03 DL QoS, and event 3A, inter-RAT handover based on QoS, can be
04 Qo triggered, and thus the more timely the handover to the target
S cell can be performed.
Inte GUI Value Range: -15~15
r Unit: dB
Fre Actual Value Range: -15~15
que
Default Value: 10
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
DlRsc B ADD W Inte Meaning: Frequency hysteresis of downlink RSCP QoS. This
pQos S UCE RF r- parameter controls the used frequency thresholds for the inter-
Hyst C LLQ D- RA frequency and inter-RAT measurement based on QoS. In event
6 OSH 02 T mode, if the inter-frequency and inter-RAT measurement events
9 O 03 Han occurred for the downlink QoS reason, the used frequency
1 MOD 09 dov threshold of the RSCP measurement quantity is equal to the used
0 UCE W er frequency threshold that is configured on the OMU server in
LLQ RF Bas coverage measurement plus this parameter. As for the impact on
OSH D- ed network performance: The larger the value of the parameter is,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CIOO B ADD W Intr Meaning: CIO of a neighboring cell. This parameter works with
ffset S UINT RF a "CIO". The sum of "CIOOffset", "CIO", and the actual measured
C ERFR D- Nod value are used for UE event evaluation or decisions on
6 EQN 02 eB handovers triggered by the RNC. In a handover algorithm, this
9 CELL 02 Soft parameter is used for moving the border of a cell. In the case of
0 MOD 01 er an event-based intra-frequency measurement or inter-RAT
0 UINT Han measurement, the UE determines whether to trigger an event
ERFR dov according to the sum of "CIOOffset", "CIO", and the actual
EQN er measured value. The UE does not consider the value of this
CELL parameter when evaluating an inter-frequency measurement
event. In the case of a periodical inter-frequency measurement or
inter-RAT measurement, the RNC determines whether to initiate
a handover based on the sum of "CIOOffset", "CIO", and the
actual measured value.
GUI Value Range: -20~20
Unit: 0.5dB
Actual Value Range: -10~10
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Default Value: 0
CIOO B ADD W Intr Meaning: CIO of a neighboring cell. This parameter works with
ffset S UINT RF a "CIO". The sum of "CIOOffset", "CIO", and the actual measured
C ERFR D- Nod value are used for UE event evaluation or decisions on
6 EQN 02 eB handovers triggered by the RNC. In a handover algorithm, this
9 CELL 02 Soft parameter is used for moving the border of a cell. In the case of
1 MOD 01 er an event-based intra-frequency measurement or inter-RAT
0 UINT Han measurement, the UE determines whether to trigger an event
ERFR dov according to the sum of "CIOOffset", "CIO", and the actual
EQN er measured value. The UE does not consider the value of this
CELL parameter when evaluating an inter-frequency measurement
event. In the case of a periodical inter-frequency measurement or
inter-RAT measurement, the RNC determines whether to initiate
a handover based on the sum of "CIOOffset", "CIO", and the
actual measured value.
GUI Value Range: -20~20
Unit: 0.5dB
Actual Value Range: -10~10
Default Value: 0
Target B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
RatCs S UCE RF r- inter-RAT CS handovers. For CS services, if "Inter-RAT
Thd C LLIN D- RA Reporting Mode" is set to EVENT_TRIGGER, this parameter is
6 TERR 02 T used to set the criterion for triggering event 3A. That is, event 3A
9 ATH 03 Han can be triggered only when the quality of the target frequency is
0 OCO 03 dov higher than this threshold and the measurement quality of the
0 V er current CS services is lower than the quality of the currently
MOD Bas used frequency. If "Inter-RAT Reporting Mode" is set to
UCE ed PERIODIC_TRIGGER, this parameter is used for inter-RAT
LLIN on handover decisions on the RNC. Note that value 0 indicates the
TERR Cov value of this parameter is smaller than -110 dBm. If "Inter-RAT
ATH erag Reporting Mode" is set to PERIODIC_TRIGGER, this
OCO e parameter is used for the assessment of coverage-based inter-
V RAT handovers. That is, Tother_RAT in the following formula.
This parameter is the absolute threshold of the cell of another
RAT (Received Signal Strength Indicator: RSSI) for the inter-
RAT handover decisions. If the quality of the cell of another
RAT in the inter-RAT measurement report fulfills the following
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
RatCs S UCE RF r- inter-RAT CS handovers. For CS services, if "Inter-RAT
Thd C LLIN D- RA Reporting Mode" is set to EVENT_TRIGGER, this parameter is
6 TERR 02 T used to set the criterion for triggering event 3A. That is, event 3A
9 ATH 03 Han can be triggered only when the quality of the target frequency is
1 OCO 03 dov higher than this threshold and the measurement quality of the
0 V er current CS services is lower than the quality of the currently
MOD Bas used frequency. If "Inter-RAT Reporting Mode" is set to
UCE ed PERIODIC_TRIGGER, this parameter is used for inter-RAT
LLIN on handover decisions on the RNC. Note that value 0 indicates the
TERR Cov value of this parameter is smaller than -110 dBm. If "Inter-RAT
ATH erag Reporting Mode" is set to PERIODIC_TRIGGER, this
OCO e parameter is used for the assessment of coverage-based inter-
V RAT handovers. That is, Tother_RAT in the following formula.
This parameter is the absolute threshold of the cell of another
RAT (Received Signal Strength Indicator: RSSI) for the inter-
RAT handover decisions. If the quality of the cell of another
RAT in the inter-RAT measurement report fulfills the following
criterion: Mother_RAT + CIO >= Tother_RAT + H/2 The system
starts the trigger timer, and makes the handover decision after the
timer expires. If the quality of the cell of another RAT fulfills the
following criterion before timeout: Mother_RAT + CIO <
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Tother_RAT - H/2 The RNC stops the timer and waits for
another inter-RAT measurement report. Where, 1 Mother_RAT is
the measurement result of the GSM RSSI. 2 Tother_RAT is the
inter-RAT handover decision threshold. 3 Cell Individual Offset
(CIO) is the offset for the cell of another RAT. 4 H represents the
hysteresis, the setting of which can reduce false decisions caused
by signal jitters.
GUI Value Range: 0~63
Unit: dBm
Actual Value Range: -110~-48(Actual value meets the condition:
Actual Value = GUI Value - 111)
Default Value: 16
Target B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
RatR9 S UCE RF r- inter-RAT PS non-HSPA service handovers. For PS non-HSPA
9PsTh C LLIN D- RA services, if "Inter-RAT Reporting Mode" is set to
d 6 TERR 02 T EVENT_TRIGGER, this parameter is used to set the criterion
9 ATH 03 Han for triggering event 3A. That is, event 3A can be triggered only
0 OCO 03 dov when the quality of the target frequency is higher than this
0 V er threshold and the measurement quality of the current PS services
MOD Bas is lower than the quality of the currently used frequency. If
UCE ed "Inter-RAT Reporting Mode" is set to PERIODIC_TRIGGER,
LLIN on this parameter is used for inter-RAT handover decisions on the
TERR Cov RNC. Note that value 0 indicates the value of this parameter is
ATH erag smaller than -110 dBm. If "Inter-RAT Reporting Mode" is set to
OCO e PERIODIC_TRIGGER, this parameter is used for the
V assessment of coverage-based inter-RAT handovers. That is,
Tother_RAT in the following formula. This parameter is the
absolute threshold of the cell of another RAT (RSSI) for the
inter-RAT handover decisions. If the quality of the cell of
another RAT in the inter-RAT measurement report fulfills the
following criterion: Mother_RAT + CIO >= Tother_RAT + H/2
The system starts the trigger timer, and makes the handover
decision after the timer expires. If the quality of the cell of
another RAT fulfills the following criterion before timeout:
Mother_RAT + CIO < Tother_RAT - H/2 The RNC stops the
timer and waits for another inter-RAT measurement report.
Where, 1 Mother_RAT is the measurement result of the GSM
RSSI. 2 Tother_RAT is the inter-RAT handover decision
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
threshold. 3 Cell Individual Offset (CIO) is the offset for the cell
of another RAT. 4 H represents the hysteresis, the setting of
which can reduce false decisions caused by signal jitters. Impact
on Radio Network Performance The setting of this parameter
affects number of hard handovers. If this parameter is set to a
small value, hard handovers are likely to be triggered, but ping-
pong handovers may occur. If this parameter is set to a large
value, hard handovers are unlikely to be triggered, but call drops
may occur.
GUI Value Range: 0~63
Unit: dBm
Actual Value Range: -110~-48(Actual value meets the condition:
Actual Value = GUI Value - 111)
Default Value: 16
Target B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
RatR9 S UCE RF r- inter-RAT PS non-HSPA service handovers. For PS non-HSPA
9PsTh C LLIN D- RA services, if "Inter-RAT Reporting Mode" is set to
d 6 TERR 02 T EVENT_TRIGGER, this parameter is used to set the criterion
9 ATH 03 Han for triggering event 3A. That is, event 3A can be triggered only
1 OCO 03 dov when the quality of the target frequency is higher than this
0 V er threshold and the measurement quality of the current PS services
MOD Bas is lower than the quality of the currently used frequency. If
UCE ed "Inter-RAT Reporting Mode" is set to PERIODIC_TRIGGER,
LLIN on this parameter is used for inter-RAT handover decisions on the
TERR Cov RNC. Note that value 0 indicates the value of this parameter is
ATH erag smaller than -110 dBm. If "Inter-RAT Reporting Mode" is set to
OCO e PERIODIC_TRIGGER, this parameter is used for the
V assessment of coverage-based inter-RAT handovers. That is,
Tother_RAT in the following formula. This parameter is the
absolute threshold of the cell of another RAT (RSSI) for the
inter-RAT handover decisions. If the quality of the cell of
another RAT in the inter-RAT measurement report fulfills the
following criterion: Mother_RAT + CIO >= Tother_RAT + H/2
The system starts the trigger timer, and makes the handover
decision after the timer expires. If the quality of the cell of
another RAT fulfills the following criterion before timeout:
Mother_RAT + CIO < Tother_RAT - H/2 The RNC stops the
timer and waits for another inter-RAT measurement report.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
RatHT S UCE RF r- inter-RAT HSPA handovers. For PS services, if "Inter-RAT
hd C LLIN D- RA Reporting Mode" is set to EVENT_TRIGGER, this parameter is
6 TERR 02 T used to set the criterion for triggering event 3A. That is, event 3A
9 ATH 03 Han can be triggered only when the quality of the target frequency is
0 OCO 03 dov higher than this threshold and the measurement quality of the
0 V er current PS services is lower than the quality of the currently used
MOD Bas frequency. If "Inter-RAT Reporting Mode" is set to
UCE ed PERIODIC_TRIGGER, this parameter is used for inter-RAT
LLIN on handover decisions on the RNC. Note that value 0 indicates the
TERR Cov value of this parameter is smaller than -110 dBm. If "Inter-RAT
ATH erag Reporting Mode" is set to PERIODIC_TRIGGER, this
OCO e parameter is used for the assessment of coverage-based inter-
V RAT handovers. That is, Tother_RAT in the following formula.
This parameter is the absolute threshold of the cell of another
RAT (RSSI) for the inter-RAT handover decisions. If the quality
of the cell of another RAT in the inter-RAT measurement report
fulfills the following criterion: Mother_RAT + CIO >=
Tother_RAT + H/2 The system starts the trigger timer, and makes
the handover decision after the timer expires. If the quality of the
cell of another RAT fulfills the following criterion before
timeout: Mother_RAT + CIO < Tother_RAT - H/2 The RNC
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
RatHT S UCE RF r- inter-RAT HSPA handovers. For PS services, if "Inter-RAT
hd C LLIN D- RA Reporting Mode" is set to EVENT_TRIGGER, this parameter is
6 TERR 02 T used to set the criterion for triggering event 3A. That is, event 3A
9 ATH 03 Han can be triggered only when the quality of the target frequency is
1 OCO 03 dov higher than this threshold and the measurement quality of the
0 V er current PS services is lower than the quality of the currently used
MOD Bas frequency. If "Inter-RAT Reporting Mode" is set to
UCE ed PERIODIC_TRIGGER, this parameter is used for inter-RAT
LLIN on handover decisions on the RNC. Note that value 0 indicates the
TERR Cov value of this parameter is smaller than -110 dBm. If "Inter-RAT
ATH erag Reporting Mode" is set to PERIODIC_TRIGGER, this
OCO e parameter is used for the assessment of coverage-based inter-
V RAT handovers. That is, Tother_RAT in the following formula.
This parameter is the absolute threshold of the cell of another
RAT (RSSI) for the inter-RAT handover decisions. If the quality
of the cell of another RAT in the inter-RAT measurement report
fulfills the following criterion: Mother_RAT + CIO >=
Tother_RAT + H/2 The system starts the trigger timer, and makes
the handover decision after the timer expires. If the quality of the
cell of another RAT fulfills the following criterion before
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Han
dov
er
Bas
ed
on
Cov
erag
e
Target B SET W Inte Meaning: Signal quality threshold for the target cell during a
RatCS S UMU RF r decision on inter-RAT handover of CS and PS combined
PSMR C LTIR D- Fre services. If the event-triggered reporting mode is used for inter-
ABTh 6 ABH 02 que RAT measurement, the RNC sends an event 3A-based
d 9 OCO 03 ncy MEASUREMENT CONTROL message containing this
0 V 02 Har parameter to a UE. Event 3A is reported when both of the
0 W d following conditions are met: -The signal quality in the cell that
RF Han operates at the target frequency is higher than this threshold.
D- dov -The signal quality in the current cell is lower than the value of
02 er UsedFreqCSPSThdEcN0 or UsedFreqCSPSThdRSCP. If the
03 Bas periodical reporting mode is used for inter-RAT measurement,
03 ed the RNC makes a decision on coverage-based inter-RAT
on handovers based on this parameter. Assume that the receiver
Cov sensitivity of a GSM mobile phone is -102 dBm, compensation
erag for fast fading is 3 dB, compensation for slow fading is 5 dBm,
e compensation for interference noise is 2 dB, and compensation
Inte for ambient noise is 2 dB. Then, the outdoor receive level should
r- not be lower than -90 dBm. The value of this parameter varies
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B SET W Inte Meaning: Signal quality threshold for the target cell during a
RatCS S UMU RF r decision on inter-RAT handover of CS and PS combined
PSMR C LTIR D- Fre services. If the event-triggered reporting mode is used for inter-
ABTh 6 ABH 02 que RAT measurement, the RNC sends an event 3A-based
d 9 OCO 03 ncy MEASUREMENT CONTROL message containing this
1 V 02 Har parameter to a UE. Event 3A is reported when both of the
0 W d following conditions are met: -The signal quality in the cell that
RF Han operates at the target frequency is higher than this threshold.
D- dov -The signal quality in the current cell is lower than the value of
02 er UsedFreqCSPSThdEcN0 or UsedFreqCSPSThdRSCP. If the
03 Bas periodical reporting mode is used for inter-RAT measurement,
03 ed the RNC makes a decision on coverage-based inter-RAT
on handovers based on this parameter. Assume that the receiver
Cov sensitivity of a GSM mobile phone is -102 dBm, compensation
erag for fast fading is 3 dB, compensation for slow fading is 5 dBm,
e compensation for interference noise is 2 dB, and compensation
Inte for ambient noise is 2 dB. Then, the outdoor receive level should
r- not be lower than -90 dBm. The value of this parameter varies
RA with the handover policy. To enable UEs to be handed over only
T to GSM cells of high quality, set this parameter to a
Han comparatively large value, for example, -85 dBm.
dov GUI Value Range: 0~63
er Unit: dBm
Bas Actual Value Range: -110~-48
ed
Default Value: 16
on
Cov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
erag
e
RsvU B SET No Non Meaning: RRM algorithm reserved U32 para 15. The 32-bit
32Par S UAL ne e parameter is reserved for further change request use. Disuse
a15 C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
0 parameter is not recommended for the configuration interface.
0 GUI Value Range: 0~4294967295
Unit: None
Actual Value Range: 0~4294967295
Default Value: 0
RsvU B SET No Non Meaning: RRM algorithm reserved U32 para 15. The 32-bit
32Par S UAL ne e parameter is reserved for further change request use. Disuse
a15 C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
1 parameter is not recommended for the configuration interface.
0 GUI Value Range: 0~4294967295
Unit: None
Actual Value Range: 0~4294967295
Default Value: 0
Penalt B SET W Inte Meaning: Penalty timer on compressed mode after coverage-
yTime S UHO RF r- based measurement expires. After coverage-based inter-
rForC C COM D- RA frequency measurement (inter-RAT or UMTS-to-LTE) expires,
MFail 6 M 02 T this timer is started and a UE cannot start the compressed mode
Cov 9 03 Han for inter-frequency measurement (inter-RAT or UMTS-to-LTE)
0 09 dov during the period specified by this timer.
0 W er GUI Value Range: 0~65535
RF Bas Unit: s
D- ed
Actual Value Range: 0~65535
02 on
DL Default Value: 10
03
02 Qo
W S
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF Inte
D- r
02 Fre
03 que
03 ncy
W Har
RF d
D- Han
02 dov
03 er
04 Bas
ed
on
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Bas
ed
on
DL
Qo
S
Penalt B SET W Inte Meaning: Penalty timer on compressed mode after coverage-
yTime S UHO RF r- based measurement expires. After coverage-based inter-
rForC C COM D- RA frequency measurement (inter-RAT or UMTS-to-LTE) expires,
MFail 6 M 02 T this timer is started and a UE cannot start the compressed mode
Cov 9 03 Han for inter-frequency measurement (inter-RAT or UMTS-to-LTE)
1 09 dov during the period specified by this timer.
0 W er GUI Value Range: 0~65535
RF Bas Unit: s
D- ed
Actual Value Range: 0~65535
02 on
DL Default Value: 10
03
02 Qo
W S
RF Inte
D- r
02 Fre
03 que
03 ncy
W Har
RF d
D- Han
02 dov
03 er
04 Bas
ed
on
Cov
erag
e
Inte
r-
RA
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
T
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
BSIC B ADD W Inte Meaning: This parameter is used to control cells where inter-
Verify S UCE RF r- RAT measurement reports are triggered. If this parameter is set
C LLIN D- RA to REQUIRED, the measurement reporting is triggered after the
6 TERR 02 T BSIC of the measured cell is decoded correctly. If the parameter
9 ATH 03 Han is set to NOT_REQUIRE, the measurement reporting is
0 ONC 03 dov triggered regardless of whether the BSIC of the measured cell is
0 OV W er decoded correctly. This parameter is valid for both periodical
MOD RF Bas reporting mode and event-triggered reporting mode. However, to
UCE D- ed ensure handover reliability, it is recommended that the system
LLIN 02 on reports only the cells whose BSIC is decoded correctly. If this
TERR 03 Cov parameter is set to NOT_REQUIRED, handovers are likely to be
ATH 05 erag triggered, but handover reliability is lower than that in the
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
BSIC B ADD W Inte Meaning: This parameter is used to control cells where inter-
Verify S UCE RF r- RAT measurement reports are triggered. If this parameter is set
C LLIN D- RA to REQUIRED, the measurement reporting is triggered after the
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ed
Dir
ect
Retr
y
HystF B ADD W Intr Meaning: Hysteresis for the inter-frequency hard handover. This
orPrdI S UCE RF a parameter is reported periodically. This parameter is used to
nterFr C LLIN D- Nod estimate the inter-frequency handover on the RNC.
eq 6 TERF 02 eB GUI Value Range: 0~29
9 REQ 02 Soft Unit: 0.5dB; 0.5dBm
0 HOC 01 er
Actual Value Range: 0~14.5
0 OV W Han
dov Default Value: 0
MOD RF
UCE D- er
LLIN 02 Me
TERF 04 asur
REQ 02 eme
HOC nt
OV Bas
ed
Dir
ect
Retr
y
HystF B ADD W Intr Meaning: Hysteresis for the inter-frequency hard handover. This
orPrdI S UCE RF a parameter is reported periodically. This parameter is used to
nterFr C LLIN D- Nod estimate the inter-frequency handover on the RNC.
eq 6 TERF 02 eB GUI Value Range: 0~29
9 REQ 02 Soft Unit: 0.5dB; 0.5dBm
1 HOC 01 er
Actual Value Range: 0~14.5
0 OV W Han
dov Default Value: 0
MOD RF
UCE D- er
LLIN 02 Me
TERF 04 asur
REQ 02 eme
HOC nt
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
OV Bas
ed
Dir
ect
Retr
y
RsvS B ADD No Non Meaning: CORRM algorithm reserved U32 Switch Para 0. The
witch0 S UCE ne e 32-bit parameter is reserved for further change request use.
C LLC Disuse statement: This parameter is used temporarily in patch
6 OAL versions and will be replaced with a new parameter in later
9 GOE versions. The new parameter ID reflects the parameter function.
0 NHP Therefore, this parameter is not recommended for the
0 ARA configuration interface.
MOD GUI Value Range: RESERVED_SWITCH_0_BIT1,
UCE RESERVED_SWITCH_0_BIT2,
LLC RESERVED_SWITCH_0_BIT3,
OAL RESERVED_SWITCH_0_BIT4,
GOE RESERVED_SWITCH_0_BIT5,
NHP RESERVED_SWITCH_0_BIT6,
ARA RESERVED_SWITCH_0_BIT7,
RESERVED_SWITCH_0_BIT8,
RESERVED_SWITCH_0_BIT9,
RESERVED_SWITCH_0_BIT10,
RESERVED_SWITCH_0_BIT11,
RESERVED_SWITCH_0_BIT12,
RESERVED_SWITCH_0_BIT13,
RESERVED_SWITCH_0_BIT14,
RESERVED_SWITCH_0_BIT15,
RESERVED_SWITCH_0_BIT16,
RESERVED_SWITCH_0_BIT17,
RESERVED_SWITCH_0_BIT18,
RESERVED_SWITCH_0_BIT19,
RESERVED_SWITCH_0_BIT20,
RESERVED_SWITCH_0_BIT21,
RESERVED_SWITCH_0_BIT22,
RESERVED_SWITCH_0_BIT23,
RESERVED_SWITCH_0_BIT24,
RESERVED_SWITCH_0_BIT25,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT26,
RESERVED_SWITCH_0_BIT27,
RESERVED_SWITCH_0_BIT28,
RESERVED_SWITCH_0_BIT29,
RESERVED_SWITCH_0_BIT30,
RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_0_BIT1,
RESERVED_SWITCH_0_BIT2,
RESERVED_SWITCH_0_BIT3,
RESERVED_SWITCH_0_BIT4,
RESERVED_SWITCH_0_BIT5,
RESERVED_SWITCH_0_BIT6,
RESERVED_SWITCH_0_BIT7,
RESERVED_SWITCH_0_BIT8,
RESERVED_SWITCH_0_BIT9,
RESERVED_SWITCH_0_BIT10,
RESERVED_SWITCH_0_BIT11,
RESERVED_SWITCH_0_BIT12,
RESERVED_SWITCH_0_BIT13,
RESERVED_SWITCH_0_BIT14,
RESERVED_SWITCH_0_BIT15,
RESERVED_SWITCH_0_BIT16,
RESERVED_SWITCH_0_BIT17,
RESERVED_SWITCH_0_BIT18,
RESERVED_SWITCH_0_BIT19,
RESERVED_SWITCH_0_BIT20,
RESERVED_SWITCH_0_BIT21,
RESERVED_SWITCH_0_BIT22,
RESERVED_SWITCH_0_BIT23,
RESERVED_SWITCH_0_BIT24,
RESERVED_SWITCH_0_BIT25,
RESERVED_SWITCH_0_BIT26,
RESERVED_SWITCH_0_BIT27,
RESERVED_SWITCH_0_BIT28,
RESERVED_SWITCH_0_BIT29,
RESERVED_SWITCH_0_BIT30,
RESERVED_SWITCH_0_BIT31,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT32
Default Value: RESERVED_SWITCH_0_BIT1:0,
RESERVED_SWITCH_0_BIT2:0,
RESERVED_SWITCH_0_BIT3:0,
RESERVED_SWITCH_0_BIT4:0,
RESERVED_SWITCH_0_BIT5:0,
RESERVED_SWITCH_0_BIT6:0,
RESERVED_SWITCH_0_BIT7:0,
RESERVED_SWITCH_0_BIT8:0,
RESERVED_SWITCH_0_BIT9:0,
RESERVED_SWITCH_0_BIT10:0,
RESERVED_SWITCH_0_BIT11:0,
RESERVED_SWITCH_0_BIT12:0,
RESERVED_SWITCH_0_BIT13:0,
RESERVED_SWITCH_0_BIT14:0,
RESERVED_SWITCH_0_BIT15:0,
RESERVED_SWITCH_0_BIT16:0,
RESERVED_SWITCH_0_BIT17:0,
RESERVED_SWITCH_0_BIT18:0,
RESERVED_SWITCH_0_BIT19:0,
RESERVED_SWITCH_0_BIT20:0,
RESERVED_SWITCH_0_BIT21:0,
RESERVED_SWITCH_0_BIT22:0,
RESERVED_SWITCH_0_BIT23:0,
RESERVED_SWITCH_0_BIT24:0,
RESERVED_SWITCH_0_BIT25:0,
RESERVED_SWITCH_0_BIT26:0,
RESERVED_SWITCH_0_BIT27:0,
RESERVED_SWITCH_0_BIT28:0,
RESERVED_SWITCH_0_BIT29:0,
RESERVED_SWITCH_0_BIT30:0,
RESERVED_SWITCH_0_BIT31:0,
RESERVED_SWITCH_0_BIT32:0
RsvS B ADD No Non Meaning: CORRM algorithm reserved U32 Switch Para 0. The
witch0 S UCE ne e 32-bit parameter is reserved for further change request use.
C LLC Disuse statement: This parameter is used temporarily in patch
6 OAL versions and will be replaced with a new parameter in later
9 GOE versions. The new parameter ID reflects the parameter function.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT5,
RESERVED_SWITCH_0_BIT6,
RESERVED_SWITCH_0_BIT7,
RESERVED_SWITCH_0_BIT8,
RESERVED_SWITCH_0_BIT9,
RESERVED_SWITCH_0_BIT10,
RESERVED_SWITCH_0_BIT11,
RESERVED_SWITCH_0_BIT12,
RESERVED_SWITCH_0_BIT13,
RESERVED_SWITCH_0_BIT14,
RESERVED_SWITCH_0_BIT15,
RESERVED_SWITCH_0_BIT16,
RESERVED_SWITCH_0_BIT17,
RESERVED_SWITCH_0_BIT18,
RESERVED_SWITCH_0_BIT19,
RESERVED_SWITCH_0_BIT20,
RESERVED_SWITCH_0_BIT21,
RESERVED_SWITCH_0_BIT22,
RESERVED_SWITCH_0_BIT23,
RESERVED_SWITCH_0_BIT24,
RESERVED_SWITCH_0_BIT25,
RESERVED_SWITCH_0_BIT26,
RESERVED_SWITCH_0_BIT27,
RESERVED_SWITCH_0_BIT28,
RESERVED_SWITCH_0_BIT29,
RESERVED_SWITCH_0_BIT30,
RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Default Value: RESERVED_SWITCH_0_BIT1:0,
RESERVED_SWITCH_0_BIT2:0,
RESERVED_SWITCH_0_BIT3:0,
RESERVED_SWITCH_0_BIT4:0,
RESERVED_SWITCH_0_BIT5:0,
RESERVED_SWITCH_0_BIT6:0,
RESERVED_SWITCH_0_BIT7:0,
RESERVED_SWITCH_0_BIT8:0,
RESERVED_SWITCH_0_BIT9:0,
RESERVED_SWITCH_0_BIT10:0,
RESERVED_SWITCH_0_BIT11:0,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT12:0,
RESERVED_SWITCH_0_BIT13:0,
RESERVED_SWITCH_0_BIT14:0,
RESERVED_SWITCH_0_BIT15:0,
RESERVED_SWITCH_0_BIT16:0,
RESERVED_SWITCH_0_BIT17:0,
RESERVED_SWITCH_0_BIT18:0,
RESERVED_SWITCH_0_BIT19:0,
RESERVED_SWITCH_0_BIT20:0,
RESERVED_SWITCH_0_BIT21:0,
RESERVED_SWITCH_0_BIT22:0,
RESERVED_SWITCH_0_BIT23:0,
RESERVED_SWITCH_0_BIT24:0,
RESERVED_SWITCH_0_BIT25:0,
RESERVED_SWITCH_0_BIT26:0,
RESERVED_SWITCH_0_BIT27:0,
RESERVED_SWITCH_0_BIT28:0,
RESERVED_SWITCH_0_BIT29:0,
RESERVED_SWITCH_0_BIT30:0,
RESERVED_SWITCH_0_BIT31:0,
RESERVED_SWITCH_0_BIT32:0
TimeT B ADD W Inte Meaning: Interval between reception of periodical reports and
oTrig S UCE RF r triggering of the inter-frequency handover.
ForPr C LLIN D- Fre GUI Value Range: 0~64000
dInter 6 TERF 02 que Unit: ms
Freq 9 REQ 03 ncy
Actual Value Range: 0~64000
0 HOC 02 Har
0 OV d Default Value: 0
W
MOD RF Han
UCE D- dov
LLIN 02 er
TERF 04 Bas
REQ 02 ed
HOC on
OV Cov
erag
e
Me
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
TimeT B ADD W Inte Meaning: Interval between reception of periodical reports and
oTrig S UCE RF r triggering of the inter-frequency handover.
ForPr C LLIN D- Fre GUI Value Range: 0~64000
dInter 6 TERF 02 que Unit: ms
Freq 9 REQ 03 ncy
Actual Value Range: 0~64000
1 HOC 02 Har
0 OV d Default Value: 0
W
MOD RF Han
UCE D- dov
LLIN 02 er
TERF 04 Bas
REQ 02 ed
HOC on
OV Cov
erag
e
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
CIOO B ADD W Intr Meaning: Cell individual offset (CIO) of neighboring GSM cells.
ffset S U2G RF a The value of this parameter together with the value of the CIO
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er
Bas
ed
on
Ser
vice
CIOO B ADD W Intr Meaning: Cell individual offset (CIO) of neighboring GSM cells.
ffset S U2G RF a The value of this parameter together with the value of the CIO
C NCE D- Nod parameter in the "ADD UEXT2GCELL" command determine
6 LL 02 eB whether to perform a handover. For details, see 3GPP TS 25.331.
9 MOD 02 Soft GUI Value Range: -50~50
1 U2G 01 er Unit: dB
0 NCE W Han
Actual Value Range: -50~50
LL RF dov
er Default Value: 0
D-
02 Inte
03 r-
09 RA
W T
RF Han
D- dov
02 er
03 Bas
03 ed
W on
RF DL
D- Qo
02 S
03 Inte
05 r-
RA
T
Han
dov
er
Bas
ed
on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Hystfo B ADD W Inte Meaning: Hysteresis for inter-RAT periodic reporting. The
rInter S UCE RF r- hysteresis can be evaluated based on the Ec/N0 or RSCP. For
RAT C LLIN D- RA details about this parameter, see 3GPP TS 25.331.
6 TERR 02 T GUI Value Range: 0~15
9 ATH 03 Han Unit: 0.5dB
0 OCO 03 dov
Actual Value Range: 0~7.5
0 V er
Bas Default Value: 0
MOD
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
Hystfo B ADD W Inte Meaning: Hysteresis for inter-RAT periodic reporting. The
rInter S UCE RF r- hysteresis can be evaluated based on the Ec/N0 or RSCP. For
RAT C LLIN D- RA details about this parameter, see 3GPP TS 25.331.
6 TERR 02 T GUI Value Range: 0~15
9 ATH 03 Han Unit: 0.5dB
1 OCO 03 dov
Actual Value Range: 0~7.5
0 V er
Bas Default Value: 0
MOD
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
TimeT B ADD W Inte Meaning: Time delay for triggering handovers to GSM cells with
oTrig S UCE RF r- verified BSIC. During the period specified by this parameter, if
ForVe C LLIN D- RA the signal quality in a neighboring GSM cell meets inter-RAT
rify 6 TERR 02 T handover decision requirements and the neighboring GSM cell is
9 ATH 03 Han verified, an inter-RAT handover is triggered. For details about
0 OCO 09 dov this parameter, see 3GPP TS 25.331.
0 V W er GUI Value Range: 0~64000
MOD RF Bas Unit: ms
UCE D- ed
Actual Value Range: 0~64000
LLIN 02 on
DL Default Value: 0
TERR 03
ATH 03 Qo
OCO W S
V RF Inte
D- r-
02 RA
04 T
02 Han
dov
er
Bas
ed
on
Cov
erag
e
Me
asur
eme
nt
Bas
ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Dir
ect
Retr
y
TimeT B ADD W Inte Meaning: Time delay for triggering handovers to GSM cells with
oTrig S UCE RF r- verified BSIC. During the period specified by this parameter, if
ForVe C LLIN D- RA the signal quality in a neighboring GSM cell meets inter-RAT
rify 6 TERR 02 T handover decision requirements and the neighboring GSM cell is
9 ATH 03 Han verified, an inter-RAT handover is triggered. For details about
1 OCO 09 dov this parameter, see 3GPP TS 25.331.
0 V W er GUI Value Range: 0~64000
MOD RF Bas Unit: ms
UCE D- ed
Actual Value Range: 0~64000
LLIN 02 on
DL Default Value: 0
TERR 03
ATH 03 Qo
OCO W S
V RF Inte
D- r-
02 RA
04 T
02 Han
dov
er
Bas
ed
on
Cov
erag
e
Me
asur
eme
nt
Bas
ed
Dir
ect
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Retr
y
TimeT B SET W Inte Meaning: Maximum time delay for triggering handovers to GSM
oTrig S UINT RF r- cells with non-verified BSIC. BSIC stands for base transceiver
ForNo C ERR D- RA station identity code of a GSM cell. During the period specified
nVerif 6 ATH 02 T by this parameter, if the signal quality in a neighboring GSM cell
y 9 OCO 03 Han meets inter-RAT handover decision requirements and the
0 V 09 dov neighboring GSM cell is not verified, an inter-RAT handover is
0 W er triggered. If this parameter is set to 65535, the RNC does not
RF Bas perform inter-RAT handovers to non-verified GSM cells. If this
D- ed parameter is set to a large value, the average number of
02 on handovers decreases, but call drops may occur. For details, see
03 DL 3GPP TS 25.331.
03 Qo GUI Value Range: 0~64000;65535
W S Unit: ms
RF Inte Actual Value Range: 0~64000, 65535
D- r-
Default Value: 0
02 RA
04 T
02 Han
dov
er
Bas
ed
on
Cov
erag
e
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TimeT B SET W Inte Meaning: Maximum time delay for triggering handovers to GSM
oTrig S UINT RF r- cells with non-verified BSIC. BSIC stands for base transceiver
ForNo C ERR D- RA station identity code of a GSM cell. During the period specified
nVerif 6 ATH 02 T by this parameter, if the signal quality in a neighboring GSM cell
y 9 OCO 03 Han meets inter-RAT handover decision requirements and the
1 V 09 dov neighboring GSM cell is not verified, an inter-RAT handover is
0 W er triggered. If this parameter is set to 65535, the RNC does not
RF Bas perform inter-RAT handovers to non-verified GSM cells. If this
D- ed parameter is set to a large value, the average number of
02 on handovers decreases, but call drops may occur. For details, see
03 DL 3GPP TS 25.331.
03 Qo GUI Value Range: 0~64000;65535
W S Unit: ms
RF Inte Actual Value Range: 0~64000, 65535
D- r-
Default Value: 0
02 RA
04 T
02 Han
dov
er
Bas
ed
on
Cov
erag
e
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
BSIC B ADD W Inte Meaning: This parameter is used to control cells where inter-
Verify S UCE RF r- RAT measurement reports are triggered. If this parameter is set
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Bas
ed
Dir
ect
Retr
y
BSIC B ADD W Inte Meaning: This parameter is used to control cells where inter-
Verify S UCE RF r- RAT measurement reports are triggered. If this parameter is set
C LLIN D- RA to REQUIRED, the measurement reporting is triggered after the
6 TERR 02 T BSIC of the measured cell is decoded correctly. If the parameter
9 ATH 03 Han is set to NOT_REQUIRE, the measurement reporting is
1 OCO 03 dov triggered regardless of whether the BSIC of the measured cell is
0 V W er decoded correctly. This parameter is valid for both periodical
MOD RF Bas reporting mode and event-triggered reporting mode. However, to
UCE D- ed ensure handover reliability, it is recommended that the system
LLIN 02 on reports only the cells whose BSIC is decoded correctly. If this
TERR 03 Cov parameter is set to NOT_REQUIRED, handovers are likely to be
ATH 05 erag triggered, but handover reliability is lower than that in the
OCO W e situation this parameter is set to REQUIRED.
V RF Inte GUI Value Range: REQUIRED(Verify mode),
D- r- NOT_REQUIRE(Non-verify mode)
02 RA Unit: None
03 T Actual Value Range: REQUIRED, NOT_REQUIRE
06 Han
Default Value: REQUIRED(Verify mode)
W dov
RF er
D- Bas
02 ed
04 on
02 Ser
vice
Inte
r-
RA
T
Han
dov
er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Bas
ed
on
Loa
d
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
NPrior B ADD W Intr Meaning: This parameter specifies the absolute priority level of
ity S UCE RF a the E-UTRA frequency. The UE compares the value of this
C LLNF D- Nod parameter with the absolute priority level of the serving cell, and
6 REQP 02 eB specifies the target frequency based on the comparison result.
9 RIOI 02 Soft That is, when the value of this parameter is greater than the
0 NFO 01 er priority level of the serving cell, the UE measures the
0 MOD W Han neighboring frequency. If the signal of cells on the neighboring
UCE RF dov frequency satisfies relevant requirements, the UE initiates the
LLNF D- er cell reselection. When the value of this parameter is smaller than
REQP 02 Inte the priority level of the serving cell, the UE measures the
RIOI 02 r neighboring frequency only when the signal of the serving cell is
NFO 03 RN weak. If the signal of cells on the neighboring frequency satisfies
W C relevant requirements, the UE initiates the cell reselection. The
RF Soft value of this parameter is set during network planning. The
D- Han greater the value of this parameter is, the easier the UE reselects
02 dov a cell on this frequency, the smaller the value of this parameter
02 er is, the harder the UE reselects a cell on this frequency. For
02 Intr details on this parameter, see 3GPP TS 25.304.
W a GUI Value Range: 0~7
RF RN Unit: None
D- C Actual Value Range: 0~7
01 Soft Default Value: None
06 Han
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
14 dov
04 er
W HS
RF UP
D- A
02 2ms
03 /10
08 ms
02 TTI
W Han
RF dov
D- er
02 PS
12 Han
00 dov
W er
RF Bet
D- wee
14 n
02 UM
26 TS
W and
RF GP
D- RS
02 HC
03 S
10 (Hi
W erar
RF chic
D- al
15 Cell
02 Stru
19 ctur
e)
W
RF Fast
D- Ret
02 urn
03 fro
m
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
08 UM
W TS
RF to
D- LTE
01 3G/
06 2G
12 Co
04 mm
W on
RF Loa
D- d
02 Ma
03 nag
09 eme
W nt
RF Cov
D- erag
02 e
01 Bas
26 ed
W PS
RF Red
D- irec
02 tion
03 fro
01 m
UM
W
TS
RF
to
D-
LTE
02
01 Inte
29 r-
RA
W
T
RF
Han
D-
dov
02
er
03
Pha
02
se 2
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
W HS
RF UP
D- A
02 Mo
03 bilit
03 y
W Ma
RF nag
D- eme
02 nt
03 Inte
04 r-
W RA
RF T
D- Han
02 dov
03 er
05 Bas
W ed
RF on
D- DL
02 Qo
03 S
06 Mo
W bilit
RF y
D- Bet
02 wee
03 n
08 UM
01 TS
and
LTE
Pha
se 1
Intr
a
Fre
que
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ncy
Har
d
Han
dov
er
PS
Ser
vice
Red
irec
tion
fro
m
UM
TS
to
LTE
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r-
RA
T
Han
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
T
Han
dov
er
Bas
ed
on
Loa
d
NA
CC(
Net
wor
k
Ass
iste
d
Cell
Cha
nge
)
NPrior B ADD W Intr Meaning: This parameter specifies the absolute priority level of
ity S UCE RF a the E-UTRA frequency. The UE compares the value of this
C LLNF D- Nod parameter with the absolute priority level of the serving cell, and
6 REQP 02 eB specifies the target frequency based on the comparison result.
9 RIOI 02 Soft That is, when the value of this parameter is greater than the
1 NFO 01 er priority level of the serving cell, the UE measures the
0 MOD W Han neighboring frequency. If the signal of cells on the neighboring
UCE RF dov frequency satisfies relevant requirements, the UE initiates the
LLNF D- er cell reselection. When the value of this parameter is smaller than
REQP 02 Inte the priority level of the serving cell, the UE measures the
RIOI 02 r neighboring frequency only when the signal of the serving cell is
NFO 03 RN weak. If the signal of cells on the neighboring frequency satisfies
W C relevant requirements, the UE initiates the cell reselection. The
RF Soft value of this parameter is set during network planning. The
D- Han greater the value of this parameter is, the easier the UE reselects
02 dov a cell on this frequency, the smaller the value of this parameter
02 er is, the harder the UE reselects a cell on this frequency. For
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
19 e)
W Fast
RF Ret
D- urn
02 fro
03 m
08 UM
W TS
RF to
D- LTE
01 3G/
06 2G
12 Co
04 mm
W on
RF Loa
D- d
02 Ma
03 nag
09 eme
W nt
RF Cov
D- erag
02 e
01 Bas
26 ed
W PS
RF Red
D- irec
02 tion
03 fro
01 m
UM
W
TS
RF
to
D-
LTE
02
01 Inte
29 r-
RA
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
W T
RF Han
D- dov
02 er
03 Pha
02 se 2
W HS
RF UP
D- A
02 Mo
03 bilit
03 y
W Ma
RF nag
D- eme
02 nt
03 Inte
04 r-
W RA
RF T
D- Han
02 dov
03 er
05 Bas
W ed
RF on
D- DL
02 Qo
03 S
06 Mo
W bilit
RF y
D- Bet
02 wee
03 n
08 UM
01 TS
and
LTE
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Pha
se 1
Intr
a
Fre
que
ncy
Har
d
Han
dov
er
PS
Ser
vice
Red
irec
tion
fro
m
UM
TS
to
LTE
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
NA
CC(
Net
wor
k
Ass
iste
d
Cell
Cha
nge
)
HOPri B ADD W Inte Meaning: Priority of the neighboring cell as a target cell for a
o S U2G RF r- handover. Value 0 indicates the highest priority and value 7
C NCE D- RA indicates the lowest priority. When this parameter takes effect,
6 LL 02 T the RNC preferentially selects the cell with the highest priority
9 MOD 03 Han as the target cell. If two or more cells have the same priority, the
0 U2G 03 dov RNC selects a target cell with the best signal quality.
0 NCE er GUI Value Range: 0~7
LL Bas Unit: None
ed
Actual Value Range: 0~7
on
Cov Default Value: 0
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
erag
e
HOPri B ADD W Inte Meaning: Priority of the neighboring cell as a target cell for a
o S U2G RF r- handover. Value 0 indicates the highest priority and value 7
C NCE D- RA indicates the lowest priority. When this parameter takes effect,
6 LL 02 T the RNC preferentially selects the cell with the highest priority
9 MOD 03 Han as the target cell. If two or more cells have the same priority, the
1 U2G 03 dov RNC selects a target cell with the best signal quality.
0 NCE er GUI Value Range: 0~7
LL Bas Unit: None
ed
Actual Value Range: 0~7
on
Cov Default Value: 0
erag
e
RatCe B ADD W Inte Meaning: Identifying the type of the inter-RAT cell
llType S UEX RF r- NO_CAPABILITY indicates that the capacity of the GSM cell
C T2GC D- RA remains unknown. It is not recommended to set the cell type to
6 ELL 02 T NO_CAPABILITY. If the cell type is NO_CAPABILITY, the
9 MOD 03 Han inter-RAT handover cannot be triggered.
0 UEX 09 dov GUI Value Range: NO_CAPABILITY(Cell capability unknown),
0 T2GC W er GSM(GSM), GPRS(GPRS), EDGE(EDGE)
ELL RF Bas Unit: None
D- ed
Actual Value Range: NO_CAPABILITY, GSM, GPRS, EDGE
02 on
DL Default Value: None
03
03 Qo
W S
RF Inte
D- r-
02 RA
03 T
05 Han
W dov
RF er
D- Bas
02 ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
03 on
06 Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
RatCe B ADD W Inte Meaning: Identifying the type of the inter-RAT cell
llType S UEX RF r- NO_CAPABILITY indicates that the capacity of the GSM cell
C T2GC D- RA remains unknown. It is not recommended to set the cell type to
6 ELL 02 T NO_CAPABILITY. If the cell type is NO_CAPABILITY, the
9 MOD 03 Han inter-RAT handover cannot be triggered.
1 UEX 09 dov GUI Value Range: NO_CAPABILITY(Cell capability unknown),
0 T2GC W er GSM(GSM), GPRS(GPRS), EDGE(EDGE)
ELL RF Bas Unit: None
D- ed
Actual Value Range: NO_CAPABILITY, GSM, GPRS, EDGE
02 on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Req2 B ADD W Inte Meaning: Minimum capability of the 2G cell required for inter-
GCap S UTY RF r- RAT handover from 3G network to 2G network. If the 2G cell is
C PRA D- RA not capable, the handover will not be performed. An EDGE cell
6 BBA 02 T is more capable of supporting PS services than a GPRS cell,
9 SIC 03 Han whereas a GPRS cell more capable than a GSM cell.
0 MOD 09 dov GUI Value Range: GSM, GPRS, EDGE
0 UTY W er Unit: None
PRA RF Bas
Actual Value Range: GSM, GPRS, EDGE
BBA D- ed
on Default Value: None
SIC 02
03 DL
03 Qo
W S
RF Inte
D- r-
02 RA
03 T
08 Han
02 dov
W er
RF Bas
D- ed
02 on
03 Cov
05 erag
e
W
RF PS
D- Han
02 dov
03 er
06 Bet
wee
n
UM
TS
and
GP
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RS
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
Req2 B ADD W Inte Meaning: Minimum capability of the 2G cell required for inter-
GCap S UTY RF r- RAT handover from 3G network to 2G network. If the 2G cell is
C PRA D- RA not capable, the handover will not be performed. An EDGE cell
6 BBA 02 T is more capable of supporting PS services than a GPRS cell,
9 SIC 03 Han whereas a GPRS cell more capable than a GSM cell.
1 MOD 09 dov GUI Value Range: GSM, GPRS, EDGE
0 UTY W er Unit: None
PRA RF Bas
Actual Value Range: GSM, GPRS, EDGE
BBA D- ed
on Default Value: None
SIC 02
03 DL
03 Qo
W S
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF Inte
D- r-
02 RA
03 T
08 Han
02 dov
W er
RF Bas
D- ed
02 on
03 Cov
05 erag
W e
RF PS
D- Han
02 dov
03 er
06 Bet
wee
n
UM
TS
and
GP
RS
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RA
T
Han
dov
er
Bas
ed
on
Loa
d
02 dov
03 er
06 Bet
wee
n
UM
TS
and
GP
RS
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
SuppR B ADD W NA Meaning: Identifying whether the inter-RAT cell supports RIM.
IMFla S UEX RF CC (RIM is used to obtain the SI/PSI information of the inter-RAT
g C T2GC D- Pro cell.) For the details of RIM process, refer to the 3GPP TS
6 ELL 07 ced 25.901 protocol. RIM:RAN Information Management;
9 MOD 00 ure SI:System Information; PSI:Packet System Information;
0 UEX 05 Opt GUI Value Range: FALSE, TRUE
0 T2GC W imi Unit: None
ELL RF zati
Actual Value Range: FALSE, TRUE
D- on
Bas Default Value: False
02
03 ed
08 on
01 Iur-
g
NA
CC(
Net
wor
k
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Ass
iste
d
Cell
Cha
nge
)
SuppR B ADD W NA Meaning: Identifying whether the inter-RAT cell supports RIM.
IMFla S UEX RF CC (RIM is used to obtain the SI/PSI information of the inter-RAT
g C T2GC D- Pro cell.) For the details of RIM process, refer to the 3GPP TS
6 ELL 07 ced 25.901 protocol. RIM:RAN Information Management;
9 MOD 00 ure SI:System Information; PSI:Packet System Information;
1 UEX 05 Opt GUI Value Range: FALSE, TRUE
0 T2GC W imi Unit: None
ELL RF zati
Actual Value Range: FALSE, TRUE
D- on
Bas Default Value: False
02
03 ed
08 on
01 Iur-
g
NA
CC(
Net
wor
k
Ass
iste
d
Cell
Cha
nge
)
Penalt B ADD W Inte Meaning: Duration after which the coverage-based inter-
yTime S UCE RF r- frequency handover, inter-frequency blind handover triggered by
rForIF C LLIN D- RA event 1F, or QoS-based inter-frequency handover to a cell can be
HoFai 6 TERF 02 T re-initiated after a failure of such handover to this cell due to the
l 9 REQ 03 Han air interface faults.
0 HOC 09 dov GUI Value Range: 0~65535
0 OV W er Unit: s
MOD RF Bas
Actual Value Range: 0~65535
UCE D- ed
on Default Value: 0
LLIN 02
TERF 03 DL
REQ 02 Qo
HOC S
OV Inte
r
Fre
que
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
Penalt B ADD W Inte Meaning: Duration after which the coverage-based inter-
yTime S UCE RF r- frequency handover, inter-frequency blind handover triggered by
rForIF C LLIN D- RA event 1F, or QoS-based inter-frequency handover to a cell can be
HoFai 6 TERF 02 T re-initiated after a failure of such handover to this cell due to the
l 9 REQ 03 Han air interface faults.
1 HOC 09 dov GUI Value Range: 0~65535
0 OV W er Unit: s
MOD RF Bas
Actual Value Range: 0~65535
UCE D- ed
on Default Value: 0
LLIN 02
TERF 03 DL
REQ 02 Qo
HOC S
OV Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Cov
erag
e
1 HOC 09 dov call is greater than the value of this parameter, the RNC
0 OV W er penalizes the UE and the UE cannot initiate such inter-frequency
MOD RF Bas handovers within the penalty period.
UCE D- ed GUI Value Range: 0~63
LLIN 02 on Unit: None
TERF 03 DL
Actual Value Range: 0~63
REQ 02 Qo
S Default Value: 3
HOC
OV Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
UEPe B ADD W Inte Meaning: Duration after which the coverage-based inter-
naltyT S UCE RF r- frequency handover, inter-frequency blind handover triggered by
imerF C LLIN D- RA event 1F, or QoS-based inter-frequency handover to a cell can be
orIFH 6 TERF 02 T re-initiated after a failure of such handover to this cell due to the
oFail 9 REQ 03 Han air interface faults.
0 HOC 09 dov GUI Value Range: 0~65535
0 OV W er Unit: s
MOD RF Bas
Actual Value Range: 0~65535
UCE D- ed
on Default Value: 0
LLIN 02
TERF 03 DL
REQ 02 Qo
HOC S
OV Inte
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
UEPe B ADD W Inte Meaning: Duration after which the coverage-based inter-
naltyT S UCE RF r- frequency handover, inter-frequency blind handover triggered by
imerF C LLIN D- RA event 1F, or QoS-based inter-frequency handover to a cell can be
orIFH 6 TERF 02 T re-initiated after a failure of such handover to this cell due to the
oFail 9 REQ 03 Han air interface faults.
1 HOC 09 dov GUI Value Range: 0~65535
0 OV W er Unit: s
MOD RF Bas
Actual Value Range: 0~65535
UCE D- ed
on Default Value: 0
LLIN 02
TERF 03 DL
REQ 02 Qo
HOC S
OV Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Bas
ed
on
Cov
erag
e
0 LLLD W Ma cover the same area. If these two types of scenario coexist in a
R RF nag network, you are advised to set this parameter to
D- eme PRIOBLINDHO. When this parameter is set to PRIOBLINDHO,
02 nt the RNC preferentially performs LDR-triggered blind inter-
01 Loa frequency handover. If none of the configured neighboring cells
06 d for blind handover meets the related requirements, the RNC then
W Res selects one cell from the configured cells that support LDR-
RF huff triggered measurement-based inter-frequency handover as the
D- ling target cell.
02 Inte GUI Value Range: BLINDHO(BLINDHO),
01 r MEASUREHO(MEASUREHO),
03 Fre PRIOBLINDHO(PRIOBLINDHO)
que Unit: None
ncy Actual Value Range: BLINDHO, MEASUREHO,
Loa PRIOBLINDHO
d Default Value: BLINDHO(BLINDHO)
Bal
anc
e
Blind B SET W Inte Meaning: The number of required measurement reports for
HOInt S UINT RF r triggering an inter-frequency blind handover. If the number of
rafreq C RAF D- Fre intra-frequency measurement reports continuously reported by
MRA 6 REQ 02 que the UE reaches or exceeds the number of intra-frequency
mount 9 HO 01 ncy measurement reports for triggering a blind handover
0 03 Loa ("BlindHOIntrafreqMRAmount"), the RNC initiates a blind
0 d handover. Measurements are terminated if the UE reports a
Bal measurement report indicating that the handover criteria are not
anc met. In this case, the RNC does not initiate a blind handover to
e the target cell.
GUI Value Range: D1, D2, D4, D8
Unit: None
Actual Value Range: 1, 2, 4, 8
Default Value: D2
Blind B SET W Inte Meaning: The number of required measurement reports for
HOInt S UINT RF r triggering an inter-frequency blind handover. If the number of
rafreq C RAF D- Fre intra-frequency measurement reports continuously reported by
MRA 6 REQ 02 que the UE reaches or exceeds the number of intra-frequency
mount 9 HO 01 ncy measurement reports for triggering a blind handover
1 03 Loa ("BlindHOIntrafreqMRAmount"), the RNC initiates a blind
0 d handover. Measurements are terminated if the UE reports a
Bal measurement report indicating that the handover criteria are not
anc met. In this case, the RNC does not initiate a blind handover to
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Blind B ADD W Ma Meaning: RSCP threshold for triggering blind handovers. If the
HOQu S UINT RF cro RSCP value of the current cell exceeds the value of this
alityC C ERFR D- & parameter, the RNC initiates a blind handover to switch the UE
onditi 6 EQN 15 Mic to the inter-frequency neighboring cell. This threshold applies to
on 9 CELL 02 ro load-balancing-based blind handovers, and directed retries from
0 MOD 01 Co- low-frequency-band cells to high-frequency-band cells.
0 UINT W carr GUI Value Range: -115~-25
ERFR RF ier Unit: dBm
EQN D- Upl
Actual Value Range: -115~-25
CELL 15 ink
Inte Default Value: -92
02
32 rfer
enc
e
Con
trol
Mul
tiba
nd
Dir
ect
Retr
y
Bas
ed
on
UE
Loc
atio
n
Blind B ADD W Ma Meaning: RSCP threshold for triggering blind handovers. If the
HOQu S UINT RF cro RSCP value of the current cell exceeds the value of this
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
alityC C ERFR D- & parameter, the RNC initiates a blind handover to switch the UE
onditi 6 EQN 15 Mic to the inter-frequency neighboring cell. This threshold applies to
on 9 CELL 02 ro load-balancing-based blind handovers, and directed retries from
1 MOD 01 Co- low-frequency-band cells to high-frequency-band cells.
0 UINT W carr GUI Value Range: -115~-25
ERFR RF ier Unit: dBm
EQN D- Upl
Actual Value Range: -115~-25
CELL 15 ink
Inte Default Value: -92
02
32 rfer
enc
e
Con
trol
Mul
tiba
nd
Dir
ect
Retr
y
Bas
ed
on
UE
Loc
atio
n
Target B ADD W Inte Meaning: RSCP threshold of the target cell for triggering inter-
FreqT S UCE RF r frequency MCLDR handovers. This parameter is used to
hdRsc C LLM D- Fre evaluate the signal quality in the periodic reports. Inter-
p 6 CLD 02 que frequency handovers are triggered only when the signal quality
9 R 01 ncy of the target cell is higher than the value of this parameter. The
0 MOD 03 Loa threshold can be reached only when RSCP and Ec/N0 of the
0 UCE W d target cell are above the RSCP and Ec/N0 specified by this
LLM RF Bal parameter.
CLD D- anc GUI Value Range: -115~-25
R 02 e Unit: dBm
01 Enh Actual Value Range: -115~-25
60 anc
Default Value: -92
ed
Mul
tiba
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
nd
Ma
nag
eme
nt
Target B ADD W Inte Meaning: RSCP threshold of the target cell for triggering inter-
FreqT S UCE RF r frequency MCLDR handovers. This parameter is used to
hdRsc C LLM D- Fre evaluate the signal quality in the periodic reports. Inter-
p 6 CLD 02 que frequency handovers are triggered only when the signal quality
9 R 01 ncy of the target cell is higher than the value of this parameter. The
1 MOD 03 Loa threshold can be reached only when RSCP and Ec/N0 of the
0 UCE W d target cell are above the RSCP and Ec/N0 specified by this
LLM RF Bal parameter.
CLD D- anc GUI Value Range: -115~-25
R 02 e Unit: dBm
01 Enh Actual Value Range: -115~-25
60 anc
Default Value: -92
ed
Mul
tiba
nd
Ma
nag
eme
nt
Target B ADD W Inte Meaning: Ec/N0 threshold of the target cell for triggering inter-
FreqT S UCE RF r frequency MCLDR handovers. This parameter is used to
hdEc C LLM D- Fre evaluate the signal quality in the periodic reports. Inter-
N0 6 CLD 02 que frequency handovers are triggered only when the signal quality
9 R 01 ncy of the target cell is higher than the value of this parameter. The
0 MOD 03 Loa threshold can be reached only when RSCP and Ec/N0 of the
0 UCE W d target cell are above the RSCP and Ec/N0 specified by this
LLM RF Bal parameter.
CLD D- anc GUI Value Range: -24~0
R 02 e Unit: dB
01 Enh Actual Value Range: -24~0
60 anc
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Target B ADD W Inte Meaning: Ec/N0 threshold of the target cell for triggering inter-
FreqT S UCE RF r frequency MCLDR handovers. This parameter is used to
hdEc C LLM D- Fre evaluate the signal quality in the periodic reports. Inter-
N0 6 CLD 02 que frequency handovers are triggered only when the signal quality
9 R 01 ncy of the target cell is higher than the value of this parameter. The
1 MOD 03 Loa threshold can be reached only when RSCP and Ec/N0 of the
0 UCE W d target cell are above the RSCP and Ec/N0 specified by this
LLM RF Bal parameter.
CLD D- anc GUI Value Range: -24~0
R 02 e Unit: dB
01 Enh Actual Value Range: -24~0
60 anc
Default Value: -12
ed
Mul
tiba
nd
Ma
nag
eme
nt
LLIN 02 on
TERR 03 Ser
ATH 06 vice
ONC W Inte
OV RF r-
D- RA
02 T
04 Han
02 dov
er
Bas
ed
on
Loa
d
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
OV RF r-
D- RA
02 T
04 Han
02 dov
er
Bas
ed
on
Loa
d
Me
asur
eme
nt
Bas
ed
Dir
ect
Retr
y
05 Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
05 Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
InterR B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
ATNC S UCE RF r- inter-RAT CS handovers. If the quality of the target frequency is
ovHO C LLIN D- RA higher than this threshold, event 3C is triggered. Value 0
CSTh 6 TERR 02 T indicates the value of this parameter is smaller than -110 dBm.
d 9 ATH 03 Han GUI Value Range: 0~63
0 ONC 05 dov Unit: dBm
0 OV W er
Actual Value Range: -110~-48(Actual value meets the condition:
MOD RF Bas
Actual Value = GUI Value - 111)
UCE D- ed
on Default Value: 21
LLIN 02
TERR 03 Ser
ATH 06 vice
ONC Inte
OV r-
RA
T
Han
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
dov
er
Bas
ed
on
Loa
d
InterR B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
ATNC S UCE RF r- inter-RAT CS handovers. If the quality of the target frequency is
ovHO C LLIN D- RA higher than this threshold, event 3C is triggered. Value 0
CSTh 6 TERR 02 T indicates the value of this parameter is smaller than -110 dBm.
d 9 ATH 03 Han GUI Value Range: 0~63
1 ONC 05 dov Unit: dBm
0 OV W er
Actual Value Range: -110~-48(Actual value meets the condition:
MOD RF Bas
Actual Value = GUI Value - 111)
UCE D- ed
on Default Value: 21
LLIN 02
TERR 03 Ser
ATH 06 vice
ONC Inte
OV r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
InterR B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
ATNC S UCE RF r- inter-RAT PS handovers. This parameter is used for
ovHO C LLIN D- RA measurement control on event 3C. If the quality of the target
PSThd 6 TERR 02 T frequency is higher than this threshold, event 3C is triggered.
9 ATH 03 Han Value 0 indicates the value of this parameter is smaller than -110
0 ONC 05 dov dBm.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
InterR B ADD W Inte Meaning: Quality requirement for the cell of another RAT during
ATNC S UCE RF r- inter-RAT PS handovers. This parameter is used for
ovHO C LLIN D- RA measurement control on event 3C. If the quality of the target
PSThd 6 TERR 02 T frequency is higher than this threshold, event 3C is triggered.
9 ATH 03 Han Value 0 indicates the value of this parameter is smaller than -110
1 ONC 05 dov dBm.
0 OV W er GUI Value Range: 0~63
MOD RF Bas Unit: dBm
UCE D- ed
Actual Value Range: -110~-48(Actual value meets the condition:
LLIN 02 on
Actual Value = GUI Value - 111)
TERR 03 Ser
vice Default Value: 21
ATH 06
ONC Inte
OV r-
RA
T
Han
dov
er
Bas
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ed
on
Loa
d
er
Bas
ed
on
Loa
d
CSSer B ADD W GS Meaning: Whether the cell allows inter-RAT handover for only
viceH S UCE RF M CS services. When the switch is set to ON, the inter-RAT
OSwit C LLH D- and handover for CS services is enabled. When the switch is set to
ch 6 OCO 07 UM OFF, the inter-RAT handover for CS services is disabled. Based
9 MM 00 TS on the Service Handover Indicator of a service and the related
0 MOD 07 Traf parameter configurations on the network side, related
0 UCE W fic measurements and inter-RAT handover are triggered
LLH RF Stee immediately once a service is set up. For hybrid services, the
OCO D- ring service handover is not triggered.
MM 02 Bas GUI Value Range: ON, OFF
03 ed Unit: None
05 on
Actual Value Range: OFF, ON
Iur-
g Default Value: OFF
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
CSSer B ADD W GS Meaning: Whether the cell allows inter-RAT handover for only
viceH S UCE RF M CS services. When the switch is set to ON, the inter-RAT
OSwit C LLH D- and handover for CS services is enabled. When the switch is set to
ch 6 OCO 07 UM OFF, the inter-RAT handover for CS services is disabled. Based
9 MM 00 TS on the Service Handover Indicator of a service and the related
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
PSSer B ADD W GS Meaning: Whether the cell allows inter-RAT handover for only
viceH S UCE RF M PS services. When the switch is set to ON, the inter-RAT
OSwit C LLH D- and handover for PS services is enabled. When the switch is set to
ch 6 OCO 07 UM OFF, the inter-RAT handover for PS services is disabled. Based
9 MM 00 TS on the Service Handover Indicator of a service and the related
0 MOD 07 Traf parameter configurations on the network side, related
0 UCE W fic measurements and inter-RAT handover are triggered
LLH RF Stee immediately once a service is set up. For hybrid services, the
OCO D- ring service handover is not triggered.
MM 02 Bas GUI Value Range: ON, OFF
03 ed Unit: None
05 on
Actual Value Range: OFF, ON
Iur-
g Default Value: OFF
Inte
r-
RA
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
T
Han
dov
er
Bas
ed
on
Ser
vice
PSSer B ADD W GS Meaning: Whether the cell allows inter-RAT handover for only
viceH S UCE RF M PS services. When the switch is set to ON, the inter-RAT
OSwit C LLH D- and handover for PS services is enabled. When the switch is set to
ch 6 OCO 07 UM OFF, the inter-RAT handover for PS services is disabled. Based
9 MM 00 TS on the Service Handover Indicator of a service and the related
1 MOD 07 Traf parameter configurations on the network side, related
0 UCE W fic measurements and inter-RAT handover are triggered
LLH RF Stee immediately once a service is set up. For hybrid services, the
OCO D- ring service handover is not triggered.
MM 02 Bas GUI Value Range: ON, OFF
03 ed Unit: None
05 on
Actual Value Range: OFF, ON
Iur-
g Default Value: OFF
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
SndLd B SET W Inte Meaning: Switch for sending load information to the GSM
Info2 S UINT RF r- network. This parameter is designed for the UMTS load-based
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
GsmIn C ERR D- RA access control strategy when the 3G-to-2G handover is required.
d 6 ATH 02 T When the UE is handed over from the UMTS network to the
9 ONC 03 Han GSM network, the RNC obtains the load information of the best
0 OV 05 dov cell and sends it to the GSM network. This parameter is valid
0 W er only for CS service. The RNC does not send UMTS cell load
RF Bas information to the GSM in PS domain.
D- ed GUI Value Range: OFF, ON
02 on Unit: None
03 Ser
Actual Value Range: OFF, ON
06 vice
Default Value: ON
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
SndLd B SET W Inte Meaning: Switch for sending load information to the GSM
Info2 S UINT RF r- network. This parameter is designed for the UMTS load-based
GsmIn C ERR D- RA access control strategy when the 3G-to-2G handover is required.
d 6 ATH 02 T When the UE is handed over from the UMTS network to the
9 ONC 03 Han GSM network, the RNC obtains the load information of the best
1 OV 05 dov cell and sends it to the GSM network. This parameter is valid
0 W er only for CS service. The RNC does not send UMTS cell load
RF Bas information to the GSM in PS domain.
D- ed GUI Value Range: OFF, ON
02 on Unit: None
03 Ser
Actual Value Range: OFF, ON
06 vice
Default Value: ON
Inte
r-
RA
T
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Han
dov
er
Bas
ed
on
Loa
d
Ncov B SET W Inte Meaning: Threshold for 2G load for outgoing inter-RAT PS
HoOn S UINT RF r- handovers. This parameter specifies the threshold for 2G load for
2GldI C ERR D- RA outgoing inter-RAT PS handovers. If the GSM load policy is
nd 6 ATH 02 T used, that is, "NcovHoOn2GldInd" in the "SET
9 ONC 03 Han UINTERRATHONCOV" command is set to ON, a non-
0 OV 05 dov coverage-based handover from the 3G cell to the 2G cell is
0 W er stopped if the uplink or downlink normalized load carried in the
RF Bas relocation response message from the 2G network exceeds the
D- ed value of this parameter.
02 on GUI Value Range: OFF, ON
03 Ser Unit: None
06 vice
Actual Value Range: OFF, ON
Inte
Default Value: ON
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
Ncov B SET W Inte Meaning: Threshold for 2G load for outgoing inter-RAT PS
HoOn S UINT RF r- handovers. This parameter specifies the threshold for 2G load for
2GldI C ERR D- RA outgoing inter-RAT PS handovers. If the GSM load policy is
nd 6 ATH 02 T used, that is, "NcovHoOn2GldInd" in the "SET
9 ONC 03 Han UINTERRATHONCOV" command is set to ON, a non-
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
CSHO B ADD W Inte Meaning: Threshold for 2G load for outgoing inter-RAT CS
Out2G S UCE RF r- handovers. If the GSM load policy is used, that is,
loadT C LLIN D- RA "NcovHoOn2GldInd" in the "SET UINTERRATHONCOV"
hd 6 TERR 07 T command is set to ON, a non-coverage-based handover from the
9 ATH 00 Han 3G cell to the 2G cell is stopped if the uplink or downlink
0 ONC 04 dov normalized load carried in the relocation response message from
0 OV W er the 2G network exceeds the value of this parameter.
MOD RF Bas GUI Value Range: 0~100
UCE D- ed Unit: %
LLIN 02 on
Actual Value Range: 0~100
TERR 03 Ser
10 vice Default Value: 80
ATH
ONC W Inte
OV RF r-
D- RA
02 T
03 Han
05 dov
W er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF Bas
D- ed
02 on
03 Loa
06 d
CSHO B ADD W Inte Meaning: Threshold for 2G load for outgoing inter-RAT CS
Out2G S UCE RF r- handovers. If the GSM load policy is used, that is,
loadT C LLIN D- RA "NcovHoOn2GldInd" in the "SET UINTERRATHONCOV"
hd 6 TERR 07 T command is set to ON, a non-coverage-based handover from the
9 ATH 00 Han 3G cell to the 2G cell is stopped if the uplink or downlink
1 ONC 04 dov normalized load carried in the relocation response message from
0 OV W er the 2G network exceeds the value of this parameter.
MOD RF Bas GUI Value Range: 0~100
UCE D- ed Unit: %
LLIN 02 on
Actual Value Range: 0~100
TERR 03 Ser
10 vice Default Value: 80
ATH
ONC W Inte
OV RF r-
D- RA
02 T
03 Han
05 dov
W er
RF Bas
D- ed
02 on
03 Loa
06 d
PSHO B ADD W Inte Meaning: Threshold for 2G load for outgoing inter-RAT PS
Out2G S UCE RF r- handovers. This parameter specifies the threshold for 2G load for
loadT C LLIN D- RA outgoing inter-RAT PS handovers. If the GSM load policy is
hd 6 TERR 07 T used, that is, "NcovHoOn2GldInd" in the "SET
9 ATH 00 Han UINTERRATHONCOV" command is set to ON, a non-
0 ONC 04 dov coverage-based handover from the 3G cell to the 2G cell is
0 OV W er stopped if the uplink or downlink normalized load carried in the
MOD RF Bas relocation response message from the 2G network exceeds the
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
PSHO B ADD W Inte Meaning: Threshold for 2G load for outgoing inter-RAT PS
Out2G S UCE RF r- handovers. This parameter specifies the threshold for 2G load for
loadT C LLIN D- RA outgoing inter-RAT PS handovers. If the GSM load policy is
hd 6 TERR 07 T used, that is, "NcovHoOn2GldInd" in the "SET
9 ATH 00 Han UINTERRATHONCOV" command is set to ON, a non-
1 ONC 04 dov coverage-based handover from the 3G cell to the 2G cell is
0 OV W er stopped if the uplink or downlink normalized load carried in the
MOD RF Bas relocation response message from the 2G network exceeds the
UCE D- ed value of this parameter.
LLIN 02 on GUI Value Range: 0~100
TERR 03 Ser Unit: %
ATH 10 vice
Actual Value Range: 0~100
ONC W Inte
Default Value: 60
OV RF r-
D- RA
02 T
03 Han
05 dov
W er
RF Bas
D- ed
02 on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
03 Loa
06 d
HspaT B SET W HS Meaning: Length of the HSPA serving cell change penalty timer.
imerL S UHO RF DP This timer shall be started after the HSPA serving cell is
en C COM D- A changed. No more serving cell change shall be performed until
6 M 01 Mo the timer expires. The value 0 means this timer shall not be
9 06 bilit started and serving cell change be initiated immediately.
0 10 y GUI Value Range: 0~1024
0 06 Ma Unit: s
W nag
Actual Value Range: 0~1024
RF eme
nt Default Value: 0
D-
01 HS
06 UP
12 A
04 Mo
bilit
y
Ma
nag
eme
nt
HspaT B SET W HS Meaning: Length of the HSPA serving cell change penalty timer.
imerL S UHO RF DP This timer shall be started after the HSPA serving cell is
en C COM D- A changed. No more serving cell change shall be performed until
6 M 01 Mo the timer expires. The value 0 means this timer shall not be
9 06 bilit started and serving cell change be initiated immediately.
1 10 y GUI Value Range: 0~1024
0 06 Ma Unit: s
W nag
Actual Value Range: 0~1024
RF eme
nt Default Value: 0
D-
01 HS
06 UP
12 A
04 Mo
bilit
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
y
Ma
nag
eme
nt
NBM B ADD W HS Meaning: The algorithms with the above values represent are as
Machs S UCE RF DP follow: ALGORITHM_REQUIRED: Always reset the mac-hs no
Reset C LLAL D- A matter the cells in question are in the same NodeB or not.
AlgoS 6 GOS 01 Mo ALGORITHM_DEPEND_ON_LCG: Reset the mac-hs only
elSwit 9 WITC 06 bilit when the cells in question are in the different local cell group.
ch 0 H 10 y GUI Value Range: ALGORITHM_REQUIRED,
0 MOD 06 Ma ALGORITHM_DEPEND_ON_LCG
UCE nag Unit: None
LLAL eme
Actual Value Range: ALGORITHM_REQUIRED,
GOS nt
ALGORITHM_DEPEND_ON_LCG
WITC
Default Value: ALGORITHM_DEPEND_ON_LCG
H
NBM B ADD W HS Meaning: The algorithms with the above values represent are as
Machs S UCE RF DP follow: ALGORITHM_REQUIRED: Always reset the mac-hs no
Reset C LLAL D- A matter the cells in question are in the same NodeB or not.
AlgoS 6 GOS 01 Mo ALGORITHM_DEPEND_ON_LCG: Reset the mac-hs only
elSwit 9 WITC 06 bilit when the cells in question are in the different local cell group.
ch 1 H 10 y GUI Value Range: ALGORITHM_REQUIRED,
0 MOD 06 Ma ALGORITHM_DEPEND_ON_LCG
UCE nag Unit: None
LLAL eme
Actual Value Range: ALGORITHM_REQUIRED,
GOS nt
ALGORITHM_DEPEND_ON_LCG
WITC
Default Value: ALGORITHM_DEPEND_ON_LCG
H
RlRstr B SET W 3G Meaning: A timer to RNC wait for radio link restoration
Tmr S USTA RF PP indication in the radio link procedure. Note: The value range of
C TETI D- R9 "RlRstrTmr" is 1 to 300000 in the current version. In a later
6 MER 01 Spe version, the value range changes into 100 to 300000. In the
9 01 cifi current version, if you enter a value within the range of 1 to 100
0 01 cati including 1, this value can still be synchronized and issued but
0 W ons the system regards the value as 11000, the recommended value.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF Call Therefore, you are advised not to enter a value smaller than 100.
D- Ree Disuse Statement:The value range of "RlRstrTmr" is 1 to 300000
14 stab in the current version. In a later version, the value range changes
01 lish into 100 to 300000. In the current version, if you enter a value
03 men within the range of 1 to 100 including 1, this value can still be
t synchronized and issued but the system regards the value as
11000, the recommended value. Therefore, you are advised not
to enter a value smaller than 100.
GUI Value Range: 1~300000
Unit: ms
Actual Value Range: 1~300000
Default Value: 11000
RlRstr B SET W 3G Meaning: A timer to RNC wait for radio link restoration
Tmr S USTA RF PP indication in the radio link procedure. Note: The value range of
C TETI D- R9 "RlRstrTmr" is 1 to 300000 in the current version. In a later
6 MER 01 Spe version, the value range changes into 100 to 300000. In the
9 01 cifi current version, if you enter a value within the range of 1 to 100
1 01 cati including 1, this value can still be synchronized and issued but
0 W ons the system regards the value as 11000, the recommended value.
RF Call Therefore, you are advised not to enter a value smaller than 100.
D- Ree Disuse Statement:The value range of "RlRstrTmr" is 1 to 300000
14 stab in the current version. In a later version, the value range changes
01 lish into 100 to 300000. In the current version, if you enter a value
03 men within the range of 1 to 100 including 1, this value can still be
t synchronized and issued but the system regards the value as
11000, the recommended value. Therefore, you are advised not
to enter a value smaller than 100.
GUI Value Range: 1~300000
Unit: ms
Actual Value Range: 1~300000
Default Value: 11000
ceOve S UNR RF DP performed before the relocation procedure when the CS services
rHspa C NC D- A are carried on the HSPA. If this parameter is set to OFF, the
SuppI 6 MOD 01 Dyn HSPA needs to be degraded to the DCH before the relocation
nd 9 UNR 06 ami procedure. If this parameter is set to ON, the HSPA need not be
1 NC 10 c degraded to the DCH before the relocation procedure.
0 19 Po GUI Value Range: OFF, ON
wer Unit: None
All
Actual Value Range: OFF, ON
ocat
ion Default Value: OFF
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1J S UCE RF r 1J. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
0 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 8
REQ 02 RN
HO 02 C
Soft
Han
dov
er
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1J S UCE RF r 1J. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331.In addition, filter coefficient and
1 HO 03 Han interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 8
REQ 02 RN
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
HO 02 C
Soft
Han
dov
er
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1J S UCE RF r detection of event 1J and sending of the measurement report. The
C LLIN D- RN value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
0 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
REQ 02 RN appropriate interval time effectively reduces the average number
HO 02 C of handovers and the number of wrong handovers, preventing
Soft unnecessary handovers.
Han GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
dov D160, D200, D240, D320, D640, D1280, D2560, D5000
er Unit: ms
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
240, 320, 640, 1280, 2560, 5000
Default Value: D640
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1J S UCE RF r detection of event 1J and sending of the measurement report. The
C LLIN D- RN value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
1 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
REQ 02 RN appropriate interval time effectively reduces the average number
HO 02 C of handovers and the number of wrong handovers, preventing
Soft unnecessary handovers.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Han GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
dov D160, D200, D240, D320, D640, D1280, D2560, D5000
er Unit: ms
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
240, 320, 640, 1280, 2560, 5000
Default Value: D640
Period B ADD W Inte Meaning: Number of times event 1J is reported after the
MRRe S UCE RF r reporting mode is changed to periodic reporting. When the
portN C LLIN D- RN number of times event 1J is reported exceeds this parameter
umfor 6 TRAF 02 C value, periodic reporting of event 1J is disabled.
1J 9 REQ 02 Soft GUI Value Range: D1, D2, D4, D8, D16, D32, D64, INFINITY
0 HO 03 Han Unit: None
0 MOD W dov
Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
UCE RF er
Default Value: D64
LLIN D- Intr
TRAF 02 a
REQ 02 RN
HO 02 C
Soft
Han
dov
er
Period B ADD W Inte Meaning: Number of times event 1J is reported after the
MRRe S UCE RF r reporting mode is changed to periodic reporting. When the
portN C LLIN D- RN number of times event 1J is reported exceeds this parameter
umfor 6 TRAF 02 C value, periodic reporting of event 1J is disabled.
1J 9 REQ 02 Soft GUI Value Range: D1, D2, D4, D8, D16, D32, D64, INFINITY
1 HO 03 Han Unit: None
0 MOD W dov
Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
UCE RF er
Default Value: D64
LLIN D- Intr
TRAF 02 a
REQ 02 RN
HO 02 C
Soft
Han
dov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er
Report B ADD W Inte Meaning: Interval at which event 1J is reported after the
Interv S UCE RF r reporting mode is changed to periodical reporting. Generally,
alfor1 C LLIN D- RN event 1J is reported only once. To avoid the loss of measurement
J 6 TRAF 02 C reports, the UE set the mode of reporting event 1J to periodical if
9 REQ 02 Soft the cell reporting event 1J is not added to the DCH active set in a
0 HO 03 Han specified period of time. Event 1J is reported for
0 MOD W dov "PeriodMRReportNumfor1J" times at the interval specified by
UCE RF er this parameter.If the mode of reporting event 1J is set to
LLIN D- Intr "NON_PERIODIC_REPORT", the UE cannot change the event
TRAF 02 a 1J reporting mode to periodical.
REQ 02 RN GUI Value Range: NON_PERIODIC_REPORT, D250, D500,
HO 02 C D1000, D2000, D4000, D8000, D16000
Soft Unit: ms
Han Actual Value Range: NON_PERIODIC_REPORT, 250, 500,
dov 1000, 2000, 4000, 8000, 16000
er
Default Value: D1000
Report B ADD W Inte Meaning: Interval at which event 1J is reported after the
Interv S UCE RF r reporting mode is changed to periodical reporting. Generally,
alfor1 C LLIN D- RN event 1J is reported only once. To avoid the loss of measurement
J 6 TRAF 02 C reports, the UE set the mode of reporting event 1J to periodical if
9 REQ 02 Soft the cell reporting event 1J is not added to the DCH active set in a
1 HO 03 Han specified period of time. Event 1J is reported for
0 MOD W dov "PeriodMRReportNumfor1J" times at the interval specified by
UCE RF er this parameter.If the mode of reporting event 1J is set to
LLIN D- Intr "NON_PERIODIC_REPORT", the UE cannot change the event
TRAF 02 a 1J reporting mode to periodical.
REQ 02 RN GUI Value Range: NON_PERIODIC_REPORT, D250, D500,
HO 02 C D1000, D2000, D4000, D8000, D16000
Soft Unit: ms
Han Actual Value Range: NON_PERIODIC_REPORT, 250, 500,
dov 1000, 2000, 4000, 8000, 16000
er
Default Value: D1000
tainer C T3GC D- RN means that the cell support delay activation. Delayed Activation
Fdd 6 ELL 02 C IE indicates that the activation of the DL power shall be delayed
9 MOD 02 Soft until an indicated CFN or until a separate activation indication is
0 UEX 03 Han received. 2)HSDSCH_SUPPORT(HSDSCH support
0 T3GC W dov indicator):when the indicator is TRUE, it means that the cell
ELL RF er support HSDSCH and enable downlink traffic to be established
D- Dir in HSDSCH. 3)FDPCH_SUPPORT(F-DPCH support
02 ect indicator):when the indicator is TRUE, it means that the cell
14 Sig support F-DPCH and enable downlink signal to be established in
00 nali F-DPCH, but the cell can not support F-DPCH if it does not
ng support HSDSCH. 4)EDCH_SUPPORT(E-DCH support
Con indicator):when the indicator is TRUE, it means that the cell
nect support E-DCH and enable uplink signal and traffic to be
ion established in E-DCH.. 5)EDCH_2MS_TTI_SUPPORT(E-DCH
Re- 2ms TTI support indicator):when the indicator is TRUE, it
esta means that the cell support E-DCH 2ms TTI.
blis 6)EDCH_2SF2_AND_2SF4_SUPPORT(E-DCH max SF
hme support 2SF2+2SF4 indicator):when the indicator is TRUE, it
nt means that the cell has E-DCH SF capability of 2SF2+2SF4.
(DS 7)EDCH_2SF2_SUPPORT(E-DCH max SF support 2SF
CR) indicator):when the indicator is TRUE, it means that the cell has
E-DCH SF capability of 2SF2. 8)EDCH_2SF4_SUPPORT(E-
DCH max SF support 2SF4 indicator):when the indicator is
TRUE, it means that the cell has E-DCH SF capability of 2SF4.
9)EDCH_SF4_SUPPORT(E-DCH max SF support SF4
indicator):when the indicator is TRUE, it means that the cell has
E-DCH SF capability of SF4. 10)EDCH_SF8_SUPPORT(E-
DCH max SF support SF8 indicator):when the indicator is
TRUE, it means that the cell has E-DCH SF capability of SF8.
11)EDCH_HARQ_IR_COMBIN_SUPPORT(E-DCH support
HARQ IR Combining indicator):when the indicator is TRUE, it
means that the cell use IR combine Mode when MAC-e PDUs
are received more than one time in E-DCH.
12)EDCH_HARQ_CHASE_COMBIN_SUPPORT(E-DCH
support HARQ CHASE Combining indicator): when the
indicator is TRUE, it means that the cell use CHASE combine
Mode when MAC-e PDUs are received more than one time in E-
DCH. 13)CPC_DTX_DRX_SUPPORT(CPC DTX-DRX support
indicator): when the indicator is TRUE, it indicates that the cell
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
FLEX_MACD_PDU_SIZE_SUPPORT,
FDPCH_SLOT_FORMAT_SUPPORT,
HSPAPLUS_DL_64QAM_SUPPORT
Default Value: None
Chann B SET W HS Meaning: This parameter specifies the value of the channel retry
elRetr S UCOI RF UP handover timer. When handover is performed and some higher
yHoTi C FTIM D- A HSPA or HSPA plus technique is supported, UTRAN will trigger
merLe 6 ER 01 2ms the reconfiguration for the higher techniques. Pingpang will
n 9 06 TTI happen when the reconfiguration is triggered immediately when
0 14 Dyn handover succeeds, because handover procedure is frequently. In
0 03 ami order to avoid the pingpang, this timer will start after handover
W c procedure is performed, and the reconfiguration will not be
RF Cha triggered until the timer expires.
D- nnel GUI Value Range: 0~999
02 Con Unit: s
11 figu Actual Value Range: 0~999
01 rati
Default Value: 2
W on
RF Con
D- trol
01 (DC
06 CC)
85 Do
W wnl
RF ink
D- Enh
01 anc
06 ed
52 L2
W SR
RF B
D- ove
01 r
06 HS
86 DP
W A
RF CP
C-
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
D- DT
01 X/
06 DR
87 X
W CP
RF C-
D- HS-
01 SC
06 CH
84 less
W ope
RF rati
D- on
01 2x2
06 MI
14 MO
04 HS
W UP
RF A
D- 2ms
01 /10
06 ms
83 TTI
W Han
RF dov
D- er
15 Do
02 wnl
09 ink
W 64Q
RF AM
D- DB-
01 HS
06 DP
36 A
W SR
RF B
D- ove
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
02 r
12 HS
00 UP
A
HC
S
(Hi
erar
chic
al
Cell
Stru
ctur
e)
Chann B SET W HS Meaning: This parameter specifies the value of the channel retry
elRetr S UCOI RF UP handover timer. When handover is performed and some higher
yHoTi C FTIM D- A HSPA or HSPA plus technique is supported, UTRAN will trigger
merLe 6 ER 01 2ms the reconfiguration for the higher techniques. Pingpang will
n 9 06 TTI happen when the reconfiguration is triggered immediately when
1 14 Dyn handover succeeds, because handover procedure is frequently. In
0 03 ami order to avoid the pingpang, this timer will start after handover
W c procedure is performed, and the reconfiguration will not be
RF Cha triggered until the timer expires.
D- nnel GUI Value Range: 0~999
02 Con Unit: s
11 figu Actual Value Range: 0~999
01 rati
Default Value: 2
W on
RF Con
D- trol
01 (DC
06 CC)
85 Do
W wnl
RF ink
D- Enh
01 anc
06 ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
52 L2
W SR
RF B
D- ove
01 r
06 HS
86 DP
W A
RF CP
D- C-
01 DT
06 X/
87 DR
W X
RF CP
D- C-
01 HS-
06 SC
84 CH
W less
RF ope
D- rati
01 on
06 2x2
14 MI
04 MO
W HS
RF UP
D- A
01 2ms
06 /10
83 ms
W TTI
RF Han
D- dov
15 er
02 Do
09 wnl
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
W ink
RF 64Q
D- AM
01 DB-
06 HS
36 DP
W A
RF SR
D- B
02 ove
12 r
00 HS
UP
A
HC
S
(Hi
erar
chic
al
Cell
Stru
ctur
e)
Chann B SET W HS Meaning: This parameter specifies the value of the channel retry
elRetr S UCOI RF UP timer. The timer will start when traffic is set up or reconfigured
yTime C FTIM D- A and some higher technique is not configured by some reason
rLen 6 ER 01 2ms except for the capability of UE or cell. Channel retry will be
9 06 TTI performed after this timer expires.
0 14 Dyn GUI Value Range: 0~180
0 03 ami Unit: s
W c Actual Value Range: 0~180
RF Cha
Default Value: 5
D- nnel
02 Con
11 figu
01 rati
W on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF Con
D- trol
01 (DC
06 CC)
94 UL
W 16Q
RF AM
D- DL
01 64Q
06 AM
93 +M
W IM
RF O
D- 4C-
15 HS
02 DP
07 A
W SR
RF B
D- ove
01 r
06 HS
52 DP
W A
RF CP
D- C-
01 DT
06 X/
86 DR
W X
RF CP
D- C-
01 HS-
06 SC
87 CH
W less
RF ope
D- rati
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
01 on
06 2x2
84 MI
W MO
RF Do
D- wnl
01 ink
06 Enh
85 anc
W ed
RF L2
D- Do
01 wnl
06 ink
83 64Q
W AM
RF Inte
D- ract
01 ive
06 and
10 Bac
08 kgr
W oun
RF d
D- Traf
15 fic
02 Cla
09 ss
W on
RF HS
D- DP
01 A
06 DB-
12 HS
06 DP
W A
RF Inte
D- ract
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
14 ive
02 and
04 Bac
W kgr
RF oun
D- d
01 Traf
06 fic
96 Cla
W ss
RF on
D- HS
15 UP
02 A
50 DC-
W HS
RF UP
D- A
01 DC-
06 HS
36 DP
W A
RF 3C-
D- HS
01 DP
06 A
30 SR
W B
RF ove
D- r
01 HS
06 UP
32 A
W Stre
RF ami
D- ng
01 Traf
06 fic
Cla
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
11 ss
12 on
HS
DP
A
Stre
ami
ng
Traf
fic
Cla
ss
on
HS
UP
A
HS
DP
A
DR
D
Chann B SET W HS Meaning: This parameter specifies the value of the channel retry
elRetr S UCOI RF UP timer. The timer will start when traffic is set up or reconfigured
yTime C FTIM D- A and some higher technique is not configured by some reason
rLen 6 ER 01 2ms except for the capability of UE or cell. Channel retry will be
9 06 TTI performed after this timer expires.
1 14 Dyn GUI Value Range: 0~180
0 03 ami Unit: s
W c Actual Value Range: 0~180
RF Cha
Default Value: 5
D- nnel
02 Con
11 figu
01 rati
W on
RF Con
D- trol
01 (DC
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
06 CC)
94 UL
W 16Q
RF AM
D- DL
01 64Q
06 AM
93 +M
W IM
RF O
D- 4C-
15 HS
02 DP
07 A
W SR
RF B
D- ove
01 r
06 HS
52 DP
W A
RF CP
D- C-
01 DT
06 X/
86 DR
W X
RF CP
D- C-
01 HS-
06 SC
87 CH
W less
RF ope
D- rati
01 on
06 2x2
84 MI
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
W MO
RF Do
D- wnl
01 ink
06 Enh
85 anc
W ed
RF L2
D- Do
01 wnl
06 ink
83 64Q
W AM
RF Inte
D- ract
01 ive
06 and
10 Bac
08 kgr
W oun
RF d
D- Traf
15 fic
02 Cla
09 ss
W on
RF HS
D- DP
01 A
06 DB-
12 HS
06 DP
W A
RF Inte
D- ract
14 ive
02 and
04 Bac
kgr
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
W oun
RF d
D- Traf
01 fic
06 Cla
96 ss
W on
RF HS
D- UP
15 A
02 DC-
50 HS
W UP
RF A
D- DC-
01 HS
06 DP
36 A
W 3C-
RF HS
D- DP
01 A
06 SR
30 B
W ove
RF r
D- HS
01 UP
06 A
32 Stre
W ami
RF ng
D- Traf
01 fic
06 Cla
11 ss
12 on
HS
DP
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
A
Stre
ami
ng
Traf
fic
Cla
ss
on
HS
UP
A
HS
DP
A
DR
D
Retry B SET W HS Meaning: This parameter specifies which HSPA technologies can
Capab S UFR RF UP be retried by UEs. When the HSPA technologies are selected and
ility C C D- A currently UE is not using them, "RNC" will initiate these HSPA
6 01 2ms technologies retry for UE.
9 06 TTI GUI Value Range: SRB_OVER_HSDPA, SRB_OVER_HSUPA,
0 14 DC- TTI_2MS, MIMO, 64QAM, DL_L2_ENHANCE, DTX_DRX,
0 03 HS HSSCCH_LESS_OPERATION, MIMO_64QAM, DC_HSDPA,
W DP UL_L2_ENHANCE, UL_16QAM, EDPCCH_BOOSTING,
RF A+ DCMIMO_HSDPA, DC_HSUPA, HSDPA_4C_MIMO,
D- MI HSDPA_4C, DBMIMO_HSDPA, DB_HSDPA
01 MO Unit: None
06 Ma Actual Value Range: SRB_OVER_HSDPA,
99 cro- SRB_OVER_HSUPA, TTI_2MS, MIMO, 64QAM,
W Mic DL_L2_ENHANCE, DTX_DRX,
RF ro HSSCCH_LESS_OPERATION, MIMO_64QAM, DC_HSDPA,
D- DC- UL_L2_ENHANCE, UL_16QAM, EDPCCH_BOOSTING,
15 HS DCMIMO_HSDPA, DC_HSUPA, HSDPA_4C_MIMO,
12 DP HSDPA_4C, DBMIMO_HSDPA, DB_HSDPA
09 A Default Value:
W 4C- SRB_OVER_HSDPA:0,SRB_OVER_HSUPA:0,TTI_2MS:0,MI
RF HS
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
D- DP MO:1,64QAM:1,DL_L2_ENHANCE:1,DTX_DRX:1,HSSCCH
15 A _LESS_OPERATION:1,MIMO_64QAM:0,DC_HSDPA:0,UL_L
02 SR 2_ENHANCE:0,UL_16QAM:0,EDPCCH_BOOSTING:0,DCMI
07 B MO_HSDPA:0,DC_HSUPA:0,HSDPA_4C_MIMO:0,HSDPA_4
W ove C:0,DBMIMO_HSDPA:0,DB_HSDPA:0
RF r
D- HS
01 DP
06 A
52 CP
W C-
RF DT
D- X/
01 DR
06 X
86 CP
W C-
RF HS-
D- SC
01 CH
06 less
87 ope
W rati
RF on
D- 2x2
01 MI
06 MO
84 Do
W wnl
RF ink
D- Enh
01 anc
06 ed
85 L2
W UL
RF Lay
D- er 2
01 Imp
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
06 rov
95 eme
W nt
RF Do
D- wnl
01 ink
06 64Q
83 AM
W E-
RF DP
D- CC
01 H
06 Boo
97 stin
W g
RF UL
D- 16Q
01 AM
06 DB-
94 HS
W DP
RF A+
D- MI
15 MO
02 DB-
27 HS
W DP
RF A
D- 3C-
15 HS
02 DP
09 A
W SR
RF B
D- ove
15 r
02 HS
50 UP
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
W A
RF DC-
D- HS
01 DP
06 A
36 MC
W -
RF HS
D- DP
01 A+
06 MI
96 MO
W DL
RF 64Q
D- AM
15 +M
02 IM
23 O
W
RF
D-
01
06
93
Retry B SET W HS Meaning: This parameter specifies which HSPA technologies can
Capab S UFR RF UP be retried by UEs. When the HSPA technologies are selected and
ility C C D- A currently UE is not using them, "RNC" will initiate these HSPA
6 01 2ms technologies retry for UE.
9 06 TTI GUI Value Range: SRB_OVER_HSDPA, SRB_OVER_HSUPA,
1 14 DC- TTI_2MS, MIMO, 64QAM, DL_L2_ENHANCE, DTX_DRX,
0 03 HS HSSCCH_LESS_OPERATION, MIMO_64QAM, DC_HSDPA,
W DP UL_L2_ENHANCE, UL_16QAM, EDPCCH_BOOSTING,
RF A+ DCMIMO_HSDPA, DC_HSUPA, HSDPA_4C_MIMO,
D- MI HSDPA_4C, DBMIMO_HSDPA, DB_HSDPA
01 MO Unit: None
06 Ma Actual Value Range: SRB_OVER_HSDPA,
99 cro- SRB_OVER_HSUPA, TTI_2MS, MIMO, 64QAM,
W Mic
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF ro DL_L2_ENHANCE, DTX_DRX,
D- DC- HSSCCH_LESS_OPERATION, MIMO_64QAM, DC_HSDPA,
15 HS UL_L2_ENHANCE, UL_16QAM, EDPCCH_BOOSTING,
12 DP DCMIMO_HSDPA, DC_HSUPA, HSDPA_4C_MIMO,
09 A HSDPA_4C, DBMIMO_HSDPA, DB_HSDPA
W 4C- Default Value:
RF HS SRB_OVER_HSDPA:0,SRB_OVER_HSUPA:0,TTI_2MS:0,MI
D- DP MO:1,64QAM:1,DL_L2_ENHANCE:1,DTX_DRX:1,HSSCCH
15 A _LESS_OPERATION:1,MIMO_64QAM:0,DC_HSDPA:0,UL_L
02 SR 2_ENHANCE:0,UL_16QAM:0,EDPCCH_BOOSTING:0,DCMI
07 B MO_HSDPA:0,DC_HSUPA:0,HSDPA_4C_MIMO:0,HSDPA_4
W ove C:0,DBMIMO_HSDPA:0,DB_HSDPA:0
RF r
D- HS
01 DP
06 A
52 CP
W C-
RF DT
D- X/
01 DR
06 X
86 CP
W C-
RF HS-
D- SC
01 CH
06 less
87 ope
W rati
RF on
D- 2x2
01 MI
06 MO
84 Do
W wnl
RF ink
D- Enh
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
01 anc
06 ed
85 L2
W UL
RF Lay
D- er 2
01 Imp
06 rov
95 eme
W nt
RF Do
D- wnl
01 ink
06 64Q
83 AM
W E-
RF DP
D- CC
01 H
06 Boo
97 stin
W g
RF UL
D- 16Q
01 AM
06 DB-
94 HS
W DP
RF A+
D- MI
15 MO
02 DB-
27 HS
W DP
RF A
D- 3C-
15 HS
02 DP
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
09 A
W SR
RF B
D- ove
15 r
02 HS
50 UP
W A
RF DC-
D- HS
01 DP
06 A
36 MC
W -
RF HS
D- DP
01 A+
06 MI
96 MO
W DL
RF 64Q
D- AM
15 +M
02 IM
23 O
W
RF
D-
01
06
93
HCSP B ADD W Intr Meaning: HCS priority of a cell in an HCS network. The value
rio S UCE RF a of this parameter depends on HCS rules. For details, see 3GPP
C LLH D- RN TS 25.304. The value 0 indicates the highest-hierarchy cell and
6 CS 01 C the value 7 indicates the lowest-hierarchy cell. High-hierarchy
9 MOD 08 Cell cells are macro cells having large coverage areas where UEs
0 UCE 01 Upd move at high speeds. Low-hierarchy cells are micro cells having
0
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
LLH W ate small coverage areas where UEs move at low speeds.
CS RF HC GUI Value Range: 0~7
D- S Unit: None
02 (Hi Actual Value Range: 0~7
12 erar
00 Default Value: 0
chic
W al
RF Cell
D- Stru
01 ctur
08 e)
02 Inte
r
RN
C
Cell
Upd
ate
HCSP B ADD W Intr Meaning: HCS priority of a cell in an HCS network. The value
rio S UCE RF a of this parameter depends on HCS rules. For details, see 3GPP
C LLH D- RN TS 25.304. The value 0 indicates the highest-hierarchy cell and
6 CS 01 C the value 7 indicates the lowest-hierarchy cell. High-hierarchy
9 MOD 08 Cell cells are macro cells having large coverage areas where UEs
1 UCE 01 Upd move at high speeds. Low-hierarchy cells are micro cells having
0 LLH W ate small coverage areas where UEs move at low speeds.
CS RF HC GUI Value Range: 0~7
D- S Unit: None
02 (Hi Actual Value Range: 0~7
12 erar
Default Value: 0
00 chic
W al
RF Cell
D- Stru
01 ctur
08 e)
02 Inte
r
RN
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
C
Cell
Upd
ate
Blind B ADD W Inte Meaning: Whether a neighboring cell is a candidate cell for blind
HoFla S UINT RF r handovers. Value FALSE indicates that the neighboring cell is
g C ERFR D- Fre not considered as a candidate cell for blind handovers. Therefore,
6 EQN 02 que blind handovers to this cell cannot be triggered. Value TRUE
9 CELL 01 ncy indicates that the cell is considered as a candidate cell for blind
0 MOD 03 Loa handovers and blind handovers to this cell can be triggered.
0 UINT W d GUI Value Range: FALSE, TRUE
ERFR RF Bal Unit: None
EQN D- anc
Actual Value Range: FALSE, TRUE
CELL 02 e
Default Value: False
12 HC
00 S
W (Hi
RF erar
D- chic
02 al
01 Cell
22 Stru
W ctur
RF e)
D- Mul
02 ti-
04 Car
00 rier
01 Swi
W tch
RF off
D- Bas
02 ed
01 on
17 Qo
S
W
RF Intr
D- a
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
02 Syst
04 em
00 Dir
ect
Retr
y
Mul
ti-
Car
rier
Swi
tch
off
Bas
ed
on
Traf
fic
Loa
d
DR
D
Intr
odu
ctio
n
Pac
kag
e
Blind B ADD W Inte Meaning: Whether a neighboring cell is a candidate cell for blind
HoFla S UINT RF r handovers. Value FALSE indicates that the neighboring cell is
g C ERFR D- Fre not considered as a candidate cell for blind handovers. Therefore,
6 EQN 02 que blind handovers to this cell cannot be triggered. Value TRUE
9 CELL 01 ncy indicates that the cell is considered as a candidate cell for blind
1 MOD 03 Loa handovers and blind handovers to this cell can be triggered.
0 UINT W d GUI Value Range: FALSE, TRUE
ERFR RF Bal Unit: None
EQN D- anc
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ed
on
Traf
fic
Loa
d
DR
D
Intr
odu
ctio
n
Pac
kag
e
Default Value: 15
TFast B ADD W HC Meaning: Time window for estimating whether the UE is in the
SpdEs S UCE RF S high-mobility state. The start point of the estimation is the
t C LLH D- (Hi moment of the last reporting of event 1D, and the backdated time
6 CSH 02 erar length is determined by this parameter. If this parameter is set to
9 O 12 chic 0, the RNC does not determine whether the UE is in the high-
0 MOD 00 al mobility state.
0 UCE Cell GUI Value Range: 0~511
LLH Stru Unit: s
CSH ctur
Actual Value Range: 0~511
O e)
Default Value: 180
TFast B ADD W HC Meaning: Time window for estimating whether the UE is in the
SpdEs S UCE RF S high-mobility state. The start point of the estimation is the
t C LLH D- (Hi moment of the last reporting of event 1D, and the backdated time
6 CSH 02 erar length is determined by this parameter. If this parameter is set to
9 O 12 chic 0, the RNC does not determine whether the UE is in the high-
1 MOD 00 al mobility state.
0 UCE Cell GUI Value Range: 0~511
LLH Stru Unit: s
CSH ctur
Actual Value Range: 0~511
O e)
Default Value: 180
TCycl B ADD W HC Meaning: Period for determine whether the UE is in the low-
eSlow S UCE RF S mobility state. The RNC periodically determines whether the UE
C LLH D- (Hi is in the low-mobility state. The smaller the value of this
6 CSH 02 erar parameter, the more frequently the state estimation is triggered.
9 O 12 chic If this parameter is set to 0, the RNC does not determine whether
0 MOD 00 al the UE is in the low-mobility state.
0 UCE Cell GUI Value Range: 0~255
LLH Stru Unit: s
CSH ctur
Actual Value Range: 0~255
O e)
Default Value: 60
TCycl B ADD W HC Meaning: Period for determine whether the UE is in the low-
eSlow S UCE RF S mobility state. The RNC periodically determines whether the UE
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
C LLH D- (Hi is in the low-mobility state. The smaller the value of this
6 CSH 02 erar parameter, the more frequently the state estimation is triggered.
9 O 12 chic If this parameter is set to 0, the RNC does not determine whether
1 MOD 00 al the UE is in the low-mobility state.
0 UCE Cell GUI Value Range: 0~255
LLH Stru Unit: s
CSH ctur
Actual Value Range: 0~255
O e)
Default Value: 60
TSlow B ADD W HC Meaning: Time window for deciding whether the UE is in the
SpdEs S UCE RF S low-mobility state. Every time the slow speed period timer
t C LLH D- (Hi expires, the RNC estimates whether the UE is in the low-
6 CSH 02 erar mobility state. This parameter specifies the duration of the timer.
9 O 12 chic If this parameter is set to 0, the RNC does not determine whether
0 MOD 00 al the UE is in the low-mobility state.
0 UCE Cell GUI Value Range: 0~511
LLH Stru Unit: s
CSH ctur
Actual Value Range: 0~511
O e)
Default Value: 240
TSlow B ADD W HC Meaning: Time window for deciding whether the UE is in the
SpdEs S UCE RF S low-mobility state. Every time the slow speed period timer
t C LLH D- (Hi expires, the RNC estimates whether the UE is in the low-
6 CSH 02 erar mobility state. This parameter specifies the duration of the timer.
9 O 12 chic If this parameter is set to 0, the RNC does not determine whether
1 MOD 00 al the UE is in the low-mobility state.
0 UCE Cell GUI Value Range: 0~511
LLH Stru Unit: s
CSH ctur
Actual Value Range: 0~511
O e)
Default Value: 240
TrigTi B ADD W Inte Meaning: Interval between detection of event 2C and sending of
me2C S UCE RF r the measurement report.
C LLIN D- Fre GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
6 TERF 02 que D160, D200, D240, D320, D640, D1280, D2560, D5000
9 REQ 01 ncy Unit: ms
0 HON 03 Loa
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
0 COV W d
240, 320, 640, 1280, 2560, 5000
MOD RF Bal
anc Default Value: D640
UCE D-
LLIN 02 e
TERF 03 Inte
REQ 04 r
HON Fre
COV que
ncy
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
TrigTi B ADD W Inte Meaning: Interval between detection of event 2C and sending of
me2C S UCE RF r the measurement report.
C LLIN D- Fre GUI Value Range: D0, D10, D20, D40, D60, D80, D100, D120,
6 TERF 02 que D160, D200, D240, D320, D640, D1280, D2560, D5000
9 REQ 01 ncy Unit: ms
1 HON 03 Loa
Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200,
0 COV W d
240, 320, 640, 1280, 2560, 5000
MOD RF Bal
anc Default Value: D640
UCE D-
LLIN 02 e
TERF 03 Inte
REQ 04 r
HON Fre
COV que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
InterF B SET W HC Meaning: Threshold of signal quality of the target frequency for
reqNC S UINT RF S triggering inter-frequency measurement. This parameter is used
ovHO C ERFR D- (Hi to set measurement control on the event 2C. The event 2C is
ThdEc 6 EQH 02 erar triggered when the signal quality of the target frequency is above
N0 9 ONC 12 chic this threshold.
0 OV 00 al GUI Value Range: -24~0
0 Cell Unit: dB
Stru
Actual Value Range: -24~0
ctur
e) Default Value: -16
InterF B SET W HC Meaning: Threshold of signal quality of the target frequency for
reqNC S UINT RF S triggering inter-frequency measurement. This parameter is used
ovHO C ERFR D- (Hi to set measurement control on the event 2C. The event 2C is
ThdEc 6 EQH 02 erar triggered when the signal quality of the target frequency is above
N0 9 ONC 12 chic this threshold.
1 OV 00 al GUI Value Range: -24~0
0 Cell Unit: dB
Stru
Actual Value Range: -24~0
ctur
e) Default Value: -16
Hystfo B ADD W Inte Meaning: Event 2C hysteresis. The hysteresis can be the Ec/No
r2C S UCE RF r or RSCP. For details, see 3GPP TS 25.331.
C LLIN D- Fre GUI Value Range: 0~29
6 TERF 02 que Unit: 0.5dB
9 REQ 01 ncy
Actual Value Range: 0~14.5
0 HON 03 Loa
0 COV d Default Value: 6
MOD Bal
UCE anc
LLIN e
TERF
REQ
HON
COV
Hystfo B ADD W Inte Meaning: Event 2C hysteresis. The hysteresis can be the Ec/No
r2C S UCE RF r or RSCP. For details, see 3GPP TS 25.331.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
04 Qo Default Value: 30
W S
RF Inte
D- r
02 Fre
03 que
05 ncy
W Har
RF d
D- Han
02 dov
03 er
06 Bas
ed
on
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
on
Loa
d
UseOf B ADD W Intr Meaning: Whether a cell uses HCS. In a HCS network, macro
Hcs S UEX RF a cells provide continuous coverage and micro cells provide
C T3GC D- RN hotspot coverage.
6 ELL 01 C GUI Value Range: USED(HCS cell), NOT_USED(Non HCS
9 MOD 08 Cell cell)
0 UEX 01 Upd Unit: None
0 T3GC W ate
Actual Value Range: USED, NOT_USED
ELL RF HC
Default Value: NOT_USED(Non HCS cell)
D- S
02 (Hi
12 erar
00 chic
W al
RF Cell
D- Stru
01 ctur
08 e)
02 Inte
r
RN
C
Cell
Upd
ate
UseOf B ADD W Intr Meaning: Whether a cell uses HCS. In a HCS network, macro
Hcs S UEX RF a cells provide continuous coverage and micro cells provide
C T3GC D- RN hotspot coverage.
6 ELL 01 C GUI Value Range: USED(HCS cell), NOT_USED(Non HCS
9 MOD 08 Cell cell)
1 UEX 01 Upd Unit: None
0 T3GC W ate
Actual Value Range: USED, NOT_USED
ELL RF HC
Default Value: NOT_USED(Non HCS cell)
D- S
02 (Hi
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
12 erar
00 chic
W al
RF Cell
D- Stru
01 ctur
08 e)
02 Inte
r
RN
C
Cell
Upd
ate
Blind B ADD W Inte Meaning: Whether a neighboring cell is a candidate cell for blind
HoFla S U2G RF r handovers. Value FALSE indicates that the neighboring cell is
g C NCE D- Syst not considered as a candidate cell for blind handovers. Therefore,
6 LL 02 em blind handovers to this cell cannot be triggered. Value TRUE
9 MOD 04 Dir indicates that the cell is considered as a candidate cell for blind
0 U2G 00 ect handovers and blind handovers to this cell can be triggered.
0 NCE 02 Retr GUI Value Range: FALSE, TRUE
LL W y Unit: None
RF DR Actual Value Range: FALSE, TRUE
D- D
Default Value: False
02 Intr
04 odu
00 ctio
n
Pac
kag
e
Blind B ADD W Inte Meaning: Whether a neighboring cell is a candidate cell for blind
HoFla S U2G RF r handovers. Value FALSE indicates that the neighboring cell is
g C NCE D- Syst not considered as a candidate cell for blind handovers. Therefore,
6 LL 02 em blind handovers to this cell cannot be triggered. Value TRUE
9 MOD 04 Dir indicates that the cell is considered as a candidate cell for blind
1 U2G 00 ect handovers and blind handovers to this cell can be triggered.
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Blind B ADD W 3G/ Meaning: Priority of the neighboring cell for a blind handover.
HOPri S U2G RF 2G The value 0 represents the highest priority and the value 30
o C NCE D- Co represents the lowest priority. Priorities 0 to 15 are assigned to
6 LL 02 mm concentric neighboring cells, which ensures successful blind
9 MOD 03 on handovers. Priorities 16 to 30 are assigned to the neighboring
0 U2G 10 Loa cells which allow blind handovers but cannot ensure successful
0 NCE W d blind handovers.
LL RF Ma GUI Value Range: 0~30
D- nag Unit: None
15 eme
Actual Value Range: 0~30
02 nt
Default Value: None
32 Mul
W tiba
RF nd
D- Dir
01 ect
06 Retr
11 y
12 Bas
ed
on
UE
Loc
atio
n
HS
DP
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
A
DR
D
Blind B ADD W 3G/ Meaning: Priority of the neighboring cell for a blind handover.
HOPri S U2G RF 2G The value 0 represents the highest priority and the value 30
o C NCE D- Co represents the lowest priority. Priorities 0 to 15 are assigned to
6 LL 02 mm concentric neighboring cells, which ensures successful blind
9 MOD 03 on handovers. Priorities 16 to 30 are assigned to the neighboring
1 U2G 10 Loa cells which allow blind handovers but cannot ensure successful
0 NCE W d blind handovers.
LL RF Ma GUI Value Range: 0~30
D- nag Unit: None
15 eme
Actual Value Range: 0~30
02 nt
Default Value: None
32 Mul
W tiba
RF nd
D- Dir
01 ect
06 Retr
11 y
12 Bas
ed
on
UE
Loc
atio
n
HS
DP
A
DR
D
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1F S UCE RF r detection of event 1F and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
TrigTi B ADD W Inte Meaning: This parameter specifies the interval time between
me1F S UCE RF r detection of event 1F and sending of the measurement report.
C LLIN D- RN The value of this parameter is associated with slow fading. If this
6 TRAF 02 C parameter is set to a greater value, the probability of incorrect
9 REQ 02 Soft decision becomes low; however, the handover algorithm
1 HO 03 Han becomes slow in responding to signal change. The time-to-
0 MOD W dov trigger mechanism is introduced for the following purposes: -
UCE RF er reducing the number of wrong event reports caused by burst
LLIN D- Intr signals, - preventing the ping-pong handover, - reducing the
TRAF 02 a impact of shadow fading on event decisions. Setting an
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraA B ADD W Inte Meaning: RSCP absolute threshold for event 1F in the software
blThd S UCE RF r handover algorithm. This parameter must be set to a value that
For1F C LLIN D- RN guarantees the quality of basic services. In addition, the setting
RSCP 6 TRAF 02 C of this parameter affects event 1F triggering. Event 1F is
9 REQ 02 Soft reported to trigger an emergent blind handover. If event 1F is
0 HO 03 Han reported for a cell in the active set, the signal quality of the
0 MOD W dov active set is poor. Under this situation, a blind handover is
UCE RF er triggered to prevent call drops. Emergent blind handovers are
LLIN D- Intr triggered in special occasions that require on-site measurement
TRAF 02 a of the pilot strength and signal quality of the best cell where the
REQ 02 RN UE is located. This function is rarely used. Therefore, this
HO 02 C parameter is set to the smallest value by default. For the event
W Soft definition, see 3GPP TS 25.331.
RF Han GUI Value Range: -115~-25
D- dov Unit: dBm
02 er Actual Value Range: -115~-25
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
IntraA B ADD W Inte Meaning: RSCP absolute threshold for event 1F in the software
blThd S UCE RF r handover algorithm. This parameter must be set to a value that
For1F C LLIN D- RN guarantees the quality of basic services. In addition, the setting
RSCP 6 TRAF 02 C of this parameter affects event 1F triggering. Event 1F is
9 REQ 02 Soft reported to trigger an emergent blind handover. If event 1F is
1 HO 03 Han reported for a cell in the active set, the signal quality of the
0 MOD W dov active set is poor. Under this situation, a blind handover is
UCE RF er triggered to prevent call drops. Emergent blind handovers are
LLIN D- Intr triggered in special occasions that require on-site measurement
TRAF 02 a of the pilot strength and signal quality of the best cell where the
REQ 02 RN UE is located. This function is rarely used. Therefore, this
HO 02 C parameter is set to the smallest value by default. For the event
W Soft definition, see 3GPP TS 25.331.
RF Han GUI Value Range: -115~-25
D- dov Unit: dBm
02 er Actual Value Range: -115~-25
03 Inte Default Value: -115
02 r
Fre
que
ncy
Har
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
d
Han
dov
er
Bas
ed
on
Cov
erag
e
IntraA B ADD W Inte Meaning: Ec/No absolute threshold for event 1F in the software
blThd S UCE RF r handover algorithm. This parameter must be set to a value that
For1F C LLIN D- RN guarantees the quality of basic services. In addition, the setting
EcNo 6 TRAF 02 C of this parameter affects event 1F triggering. Event 1F is
9 REQ 02 Soft reported to trigger an emergent blind handover. If event 1F is
0 HO 03 Han reported for a cell in the active set, the signal quality of the
0 MOD W dov active set is poor. Under this situation, a blind handover is
UCE RF er triggered to prevent call drops. Emergent blind handovers are
LLIN D- Intr triggered in special occasions that require on-site measurement
TRAF 02 a of the pilot strength and signal quality of the best cell where the
REQ 02 RN UE is located. This function is rarely used. Therefore, this
HO 02 C parameter is set to the smallest value by default. For the event
W Soft definition, see 3GPP TS 25.331.
RF Han GUI Value Range: -24~0
D- dov Unit: dB
02 er Actual Value Range: -24~0
03 Inte Default Value: -24
02 r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
on
Cov
erag
e
IntraA B ADD W Inte Meaning: Ec/No absolute threshold for event 1F in the software
blThd S UCE RF r handover algorithm. This parameter must be set to a value that
For1F C LLIN D- RN guarantees the quality of basic services. In addition, the setting
EcNo 6 TRAF 02 C of this parameter affects event 1F triggering. Event 1F is
9 REQ 02 Soft reported to trigger an emergent blind handover. If event 1F is
1 HO 03 Han reported for a cell in the active set, the signal quality of the
0 MOD W dov active set is poor. Under this situation, a blind handover is
UCE RF er triggered to prevent call drops. Emergent blind handovers are
LLIN D- Intr triggered in special occasions that require on-site measurement
TRAF 02 a of the pilot strength and signal quality of the best cell where the
REQ 02 RN UE is located. This function is rarely used. Therefore, this
HO 02 C parameter is set to the smallest value by default. For the event
W Soft definition, see 3GPP TS 25.331.
RF Han GUI Value Range: -24~0
D- dov Unit: dB
02 er Actual Value Range: -24~0
03 Inte Default Value: -24
02 r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
or1F S UCE RF r 1F. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331. In addition, filter coefficient
0 HO 03 Han and interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
UCE RF er Unit: 0.5dB
LLIN D- Intr Actual Value Range: 0~7.5
TRAF 02 a
Default Value: 8
REQ 02 RN
HO 02 C
W Soft
RF Han
D- dov
02 er
03 Inte
02 r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
HystF B ADD W Inte Meaning: This parameter specifies the hysteretic value for event
or1F S UCE RF r 1F. The value of this parameter is associated with the slow
C LLIN D- RN fading, and it can be used to reduce ping-pong handovers and
6 TRAF 02 C incorrect handovers. For details on the definition of this
9 REQ 02 Soft parameter, see 3GPP TS 25.331. In addition, filter coefficient
1 HO 03 Han and interval time must be considered in setting this parameter.
0 MOD W dov GUI Value Range: 0~15
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Blind B ADD W Inte Meaning: Quality threshold for triggering an emergent blind
HORS S UCE RF r handover to a cell in the event 1F report. A blind handover is
CP1F C LLIN D- Fre triggered only when the signal quality of a cell in the event 1F
Thres 6 TRAF 02 que report exceeds the value of this parameter. Otherwise, the report
hold 9 REQ 03 ncy is discarded. This parameter is used to increase the success rate
0 HO 02 Har of blind handovers. If the signal quality of all the cells in the
0 MOD d event 1F report is poor, the UE may be located at the edge of the
UCE Han coverage area. Under this situation, triggering blind handovers
LLIN dov may cause call drops.
TRAF er GUI Value Range: -115~-25
REQ Bas Unit: dBm
HO ed
Actual Value Range: -115~-25
on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Blind B ADD W Inte Meaning: Quality threshold for triggering an emergent blind
HORS S UCE RF r handover to a cell in the event 1F report. A blind handover is
CP1F C LLIN D- Fre triggered only when the signal quality of a cell in the event 1F
Thres 6 TRAF 02 que report exceeds the value of this parameter. Otherwise, the report
hold 9 REQ 03 ncy is discarded. This parameter is used to increase the success rate
1 HO 02 Har of blind handovers. If the signal quality of all the cells in the
0 MOD d event 1F report is poor, the UE may be located at the edge of the
UCE Han coverage area. Under this situation, triggering blind handovers
LLIN dov may cause call drops.
TRAF er GUI Value Range: -115~-25
REQ Bas Unit: dBm
HO ed
Actual Value Range: -115~-25
on
Cov Default Value: -115
erag
e
IFHoP B ADD W Inte Meaning: Duration after which the coverage-based inter-
ingPo S UCE RF r- frequency handover, inter-frequency blind handover triggered by
ngTim C LLIN D- RA event 1F, or QoS-based inter-frequency handover can be re-
er 6 TERF 02 T initiated after the success of such handover.
9 REQ 03 Han GUI Value Range: 0~65535
0 HOC 09 dov Unit: s
0 OV W er
Actual Value Range: 0~65535
MOD RF Bas
ed Default Value: 0
UCE D-
LLIN 02 on
TERF 03 DL
REQ 02 Qo
HOC S
OV Inte
r
Fre
que
ncy
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
IFHoP B ADD W Inte Meaning: Duration after which the coverage-based inter-
ingPo S UCE RF r- frequency handover, inter-frequency blind handover triggered by
ngTim C LLIN D- RA event 1F, or QoS-based inter-frequency handover can be re-
er 6 TERF 02 T initiated after the success of such handover.
9 REQ 03 Han GUI Value Range: 0~65535
1 HOC 09 dov Unit: s
0 OV W er
Actual Value Range: 0~65535
MOD RF Bas
ed Default Value: 0
UCE D-
LLIN 02 on
TERF 03 DL
REQ 02 Qo
HOC S
OV Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
erag
e
InterR B ADD W Inte Meaning: Length of the timer to avoid ping-pong handovers
ATPin S UCE RF r- between 2G and 3G networks. When a UE in the CS domain is
gPong C LLIN D- RA handed over from a 2G network to a 3G network, the system
Timer 6 TERR 02 T increases the hysteresis used for event 3A to prevent the ping-
9 ATH 03 Han pong handover between the 2G network and the 3G network in
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
0 OCO 03 dov the period specified by this parameter. During the penalty time,
0 V er the previous periodical report will be changed to the event 3A
MOD Bas report. The value 0 indicates that the system does not take
UCE ed measures to avoid ping-pong handover between 2G and 3G
LLIN on networks.
TERR Cov GUI Value Range: 0~65535
ATH erag Unit: s
OCO e
Actual Value Range: 0~65535
V
Default Value: 0
InterR B ADD W Inte Meaning: Length of the timer to avoid ping-pong handovers
ATPin S UCE RF r- between 2G and 3G networks. When a UE in the CS domain is
gPong C LLIN D- RA handed over from a 2G network to a 3G network, the system
Timer 6 TERR 02 T increases the hysteresis used for event 3A to prevent the ping-
9 ATH 03 Han pong handover between the 2G network and the 3G network in
1 OCO 03 dov the period specified by this parameter. During the penalty time,
0 V er the previous periodical report will be changed to the event 3A
MOD Bas report. The value 0 indicates that the system does not take
UCE ed measures to avoid ping-pong handover between 2G and 3G
LLIN on networks.
TERR Cov GUI Value Range: 0~65535
ATH erag Unit: s
OCO e
Actual Value Range: 0~65535
V
Default Value: 0
Period B ADD W Inte Meaning: Sets the interval between the failure in the inter-
For2B S UCE RF r frequency handover triggered by the event 2B and the inter-
C LLIN D- Fre frequency handover retry.
6 TERF 02 que GUI Value Range: 1~64
9 REQ 03 ncy Unit: 500ms
0 HOC 02 Har
Actual Value Range: 500~32000
0 OV W d
Han Default Value: 1
MOD RF
UCE D- dov
LLIN 02 er
TERF 03 Bas
REQ 04 ed
HOC on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
OV Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
Period B ADD W Inte Meaning: Sets the interval between the failure in the inter-
For2B S UCE RF r frequency handover triggered by the event 2B and the inter-
C LLIN D- Fre frequency handover retry.
6 TERF 02 que GUI Value Range: 1~64
9 REQ 03 ncy Unit: 500ms
1 HOC 02 Har
Actual Value Range: 500~32000
0 OV W d
Han Default Value: 1
MOD RF
UCE D- dov
LLIN 02 er
TERF 03 Bas
REQ 04 ed
HOC on
OV Cov
erag
e
Inte
r
Fre
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
er
Bas
ed
on
DL
Qo
S
TERF 03 Inte
REQ 04 r
HON Fre
COV que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
Period B ADD W Inte Meaning: Interval between handover attempts for event 3A.
For3A S UCE RF r- GUI Value Range: 1~64
C LLIN D- RA Unit: 500ms
6 TERR 02 T
Actual Value Range: 500~32000
9 ATH 03 Han
0 OCO 03 dov Default Value: 1
0 V er
MOD Bas
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
Period B ADD W Inte Meaning: Interval between handover attempts for event 3A.
For3A S UCE RF r- GUI Value Range: 1~64
C LLIN D- RA Unit: 500ms
6 TERR 02 T
Actual Value Range: 500~32000
9 ATH 03 Han
1 OCO 03 dov Default Value: 1
0 V er
MOD Bas
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
Amnt B ADD W Inte Meaning: Number of handover attempts after the UE sends to the
OfRpt S UCE RF r- CN a message indicating that inter-RAT handovers triggered by
3A C LLIN D- RA event 3A fail.
6 TERR 02 T GUI Value Range: 0~63
9 ATH 03 Han Unit: None
0 OCO 03 dov
Actual Value Range: 0~62, 63(Infinity)
0 V er
Bas Default Value: 4
MOD
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
Amnt B ADD W Inte Meaning: Number of handover attempts after the UE sends to the
OfRpt S UCE RF r- CN a message indicating that inter-RAT handovers triggered by
3A C LLIN D- RA event 3A fail.
6 TERR 02 T GUI Value Range: 0~63
9 ATH 03 Han Unit: None
1 OCO 03 dov
Actual Value Range: 0~62, 63(Infinity)
0 V er
Bas Default Value: 4
MOD
UCE ed
LLIN on
TERR Cov
ATH erag
OCO e
V
Period B ADD W Inte Meaning: Interval between handover attempts for event 3A.
For3C S UCE RF r- GUI Value Range: 1~64
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Period B ADD W Inte Meaning: Interval between handover attempts for event 3A.
For3C S UCE RF r- GUI Value Range: 1~64
C LLIN D- RA Unit: 500ms
6 TERR 02 T
Actual Value Range: 500~32000
9 ATH 03 Han
1 ONC 05 dov Default Value: 4
0 OV W er
MOD RF Bas
UCE D- ed
LLIN 02 on
TERR 03 Ser
ATH 06 vice
ONC Inte
OV r-
RA
T
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Han
dov
er
Bas
ed
on
Loa
d
Amnt B ADD W Inte Meaning: Number of handover attempts after the UE sends to the
OfRpt S UCE RF r- CN a message indicating that inter-RAT handovers triggered by
3C C LLIN D- RA event 3C fail.
6 TERR 02 T GUI Value Range: 0~63
9 ATH 03 Han Unit: None
0 ONC 05 dov
Actual Value Range: 0~62, 63(Infinity)
0 OV W er
Bas Default Value: 1
MOD RF
UCE D- ed
LLIN 02 on
TERR 03 Ser
ATH 06 vice
ONC Inte
OV r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
Amnt B ADD W Inte Meaning: Number of handover attempts after the UE sends to the
OfRpt S UCE RF r- CN a message indicating that inter-RAT handovers triggered by
3C C LLIN D- RA event 3C fail.
6 TERR 02 T GUI Value Range: 0~63
9 ATH 03 Han Unit: None
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Report B ADD W Inte Meaning: Interval at which event 1A is reported after the
Interv S UCE RF r reporting mode is changed to periodical reporting. Generally,
alfor1 C LLIN D- RN event 1A is reported only once. To avoid the loss of
A 6 TRAF 02 C measurement reports, the UE sets the mode of reporting event
9 REQ 02 Soft 1A to periodical if the cell reporting event 1A is not added to the
0 HO 03 Han active set in a specified period of time. Event 1A is reported for
0 MOD W dov "PeriodMRReportNumfor1A" times at the interval specified by
UCE RF er this parameter. If the mode of reporting event 1A is set to
LLIN D- Intr "NON_PERIODIC_REPORT", the UE cannot change the event
TRAF 02 a 1A reporting mode to periodical.
REQ 02 RN GUI Value Range: NON_PERIODIC_REPORT, D250, D500,
HO 02 C D1000, D2000, D4000, D8000, D16000
Soft Unit: ms
Han Actual Value Range: NON_PERIODIC_REPORT, 250, 500,
dov 1000, 2000, 4000, 8000, 16000
er
Default Value: D4000
Report B ADD W Inte Meaning: Interval at which event 1A is reported after the
Interv S UCE RF r reporting mode is changed to periodical reporting. Generally,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Report B ADD W Inte Meaning: Interval at which event 1A is reported after the
Interv S UCE RF r reporting mode is changed to periodical reporting. Generally,
alfor1 C LLIN D- RN event 1C is reported only once. To avoid the loss of
C 6 TRAF 02 C measurement reports, the UE set the mode of reporting event 1C
9 REQ 02 Soft to periodical if the cell reporting event 1C is not added to the
0 HO 03 Han active set in a specified period of time. Event 1C is reported for
0 MOD W dov "PeriodMRReportNumfor1C" times at the interval specified by
UCE RF er this parameter.If the mode of reporting event 1C is set to
LLIN D- Intr "NON_PERIODIC_REPORT", the UE cannot change the event
TRAF 02 a 1C reporting mode to periodical.
REQ 02 RN GUI Value Range: NON_PERIODIC_REPORT, D250, D500,
HO 02 C D1000, D2000, D4000, D8000, D16000
Soft Unit: ms
Han Actual Value Range: NON_PERIODIC_REPORT, 250, 500,
dov 1000, 2000, 4000, 8000, 16000
er
Default Value: D4000
Report B ADD W Inte Meaning: Interval at which event 1A is reported after the
Interv S UCE RF r reporting mode is changed to periodical reporting. Generally,
alfor1 C LLIN D- RN event 1C is reported only once. To avoid the loss of
C 6 TRAF 02 C measurement reports, the UE set the mode of reporting event 1C
9 REQ 02 Soft to periodical if the cell reporting event 1C is not added to the
1 HO 03 Han active set in a specified period of time. Event 1C is reported for
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Period B ADD W Inte Meaning: Number of times event 1A is reported after the
MRRe S UCE RF r reporting mode is changed to periodic reporting. When the
portN C LLIN D- RN number of times event 1A is reported exceeds this parameter
umfor 6 TRAF 02 C value, periodic reporting of event 1A is disabled.
1A 9 REQ 02 Soft GUI Value Range: D1, D2, D4, D8, D16, D32, D64, INFINITY
0 HO 03 Han Unit: None
0 MOD W dov
Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
UCE RF er
Default Value: D16
LLIN D- Intr
TRAF 02 a
REQ 02 RN
HO 02 C
Soft
Han
dov
er
Period B ADD W Inte Meaning: Number of times event 1A is reported after the
MRRe S UCE RF r reporting mode is changed to periodic reporting. When the
portN C LLIN D- RN number of times event 1A is reported exceeds this parameter
umfor 6 TRAF 02 C value, periodic reporting of event 1A is disabled.
1A 9 REQ 02 Soft GUI Value Range: D1, D2, D4, D8, D16, D32, D64, INFINITY
1 HO 03 Han Unit: None
0 MOD W dov
Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
UCE RF er
Default Value: D16
LLIN D- Intr
TRAF 02 a
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
REQ 02 RN
HO 02 C
Soft
Han
dov
er
Period B ADD W Inte Meaning: Number of times event 1C is reported after the
MRRe S UCE RF r reporting mode is changed to periodic reporting. When the
portN C LLIN D- RN number of times event 1C is reported exceeds this parameter
umfor 6 TRAF 02 C value, periodic reporting of event 1C is disabled.
1C 9 REQ 02 Soft GUI Value Range: D1, D2, D4, D8, D16, D32, D64, INFINITY
0 HO 03 Han Unit: None
0 MOD W dov
Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
UCE RF er
Default Value: D16
LLIN D- Intr
TRAF 02 a
REQ 02 RN
HO 02 C
Soft
Han
dov
er
Period B ADD W Inte Meaning: Number of times event 1C is reported after the
MRRe S UCE RF r reporting mode is changed to periodic reporting. When the
portN C LLIN D- RN number of times event 1C is reported exceeds this parameter
umfor 6 TRAF 02 C value, periodic reporting of event 1C is disabled.
1C 9 REQ 02 Soft GUI Value Range: D1, D2, D4, D8, D16, D32, D64, INFINITY
1 HO 03 Han Unit: None
0 MOD W dov
Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
UCE RF er
Default Value: D16
LLIN D- Intr
TRAF 02 a
REQ 02 RN
HO 02 C
Soft
Han
dov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er
NPrio B ADD W Inte Meaning: Whether to configure the priority flag for a
Flag S UINT RF r neighboring cell. The value FALSE indicates that the
C RAF D- Fre neighboring cell priority is not configured. In the algorithm of
6 REQ 02 que neighboring cell combination, the cell with an invalid priority is
9 NCE 03 ncy the last one to be considered as the measurement object. The
0 LL 02 Har value TRUE indicates that the neighboring cell priority is
0 MOD d configured. When the algorithm of neighboring cell combination
UINT Han (controlled by "HO_MC_NCELL_COMBINE_SWITCH") is
RAF dov enabled and the total number of neighboring cells to all cells in
REQ er the active set exceeds 32, the RNC considers this parameter as
NCE Bas one of conditions for selecting the neighboring cells. That is, a
LL ed neighboring cell with a high priority is preferentially selected. If
on a neighboring cell is not configured with the priority flag, the
Cov lowest priority is assigned to this cell.
erag GUI Value Range: FALSE, TRUE
e Unit: None
Actual Value Range: FALSE, TRUE
Default Value: False
NPrio B ADD W Inte Meaning: Whether to configure the priority flag for a
Flag S UINT RF r neighboring cell. The value FALSE indicates that the
C RAF D- Fre neighboring cell priority is not configured. In the algorithm of
6 REQ 02 que neighboring cell combination, the cell with an invalid priority is
9 NCE 03 ncy the last one to be considered as the measurement object. The
1 LL 02 Har value TRUE indicates that the neighboring cell priority is
0 MOD d configured. When the algorithm of neighboring cell combination
UINT Han (controlled by "HO_MC_NCELL_COMBINE_SWITCH") is
RAF dov enabled and the total number of neighboring cells to all cells in
REQ er the active set exceeds 32, the RNC considers this parameter as
NCE Bas one of conditions for selecting the neighboring cells. That is, a
LL ed neighboring cell with a high priority is preferentially selected. If
on a neighboring cell is not configured with the priority flag, the
Cov lowest priority is assigned to this cell.
erag GUI Value Range: FALSE, TRUE
e Unit: None
Actual Value Range: FALSE, TRUE
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
NPrio B ADD W Inte Meaning: Priority of a neighboring cell. The smaller the value of
S UINT RF r this parameter, the higher the priority of a neighboring cell. If
C RAF D- RN "NPrioFlag" of a neighboring cell is set to False, the neighboring
6 REQ 02 C cell has the lowest priority. If the total number of neighboring
9 NCE 02 Soft cells exceeds 32, the RNC considers this parameter as a
0 LL 03 Han condition for selecting neighboring cells. That is, a neighboring
0 MOD W dov cell with a high priority is preferentially measured.
UINT RF er GUI Value Range: 0~30
RAF D- Intr Unit: None
REQ 02 a Actual Value Range: 0~30
NCE 02 RN
Default Value: None
LL 02 C
Soft
Han
dov
er
NPrio B ADD W Inte Meaning: Priority of a neighboring cell. The smaller the value of
S UINT RF r this parameter, the higher the priority of a neighboring cell. If
C RAF D- RN "NPrioFlag" of a neighboring cell is set to False, the neighboring
6 REQ 02 C cell has the lowest priority. If the total number of neighboring
9 NCE 02 Soft cells exceeds 32, the RNC considers this parameter as a
1 LL 03 Han condition for selecting neighboring cells. That is, a neighboring
0 MOD W dov cell with a high priority is preferentially measured.
UINT RF er GUI Value Range: 0~30
RAF D- Intr Unit: None
REQ 02 a Actual Value Range: 0~30
NCE 02 RN
Default Value: None
LL 02 C
Soft
Han
dov
er
IntraF B SET No Non Meaning: Whether the detection function of missing intra-
reqNC S UNC ne e frequency neighboring cells is enabled. This switch is turned on.
ellDet C ELLD The function of detecting missing intra-frequency neighboring
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ectSwi 6 ETEC cells is enabled. That is, the UE reports the intra-frequency
tch 9 TSWI measurement results in the detection set to the RNC and the
0 TCH RNC then reports the detected missing intra-frequency
0 neighboring cells to the Nastar or LMT. This switch is turned off.
The function of detecting missing intra-frequency neighboring
cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
IntraF B SET No Non Meaning: Whether the detection function of missing intra-
reqNC S UNC ne e frequency neighboring cells is enabled. This switch is turned on.
ellDet C ELLD The function of detecting missing intra-frequency neighboring
ectSwi 6 ETEC cells is enabled. That is, the UE reports the intra-frequency
tch 9 TSWI measurement results in the detection set to the RNC and the
1 TCH RNC then reports the detected missing intra-frequency
0 neighboring cells to the Nastar or LMT. This switch is turned off.
The function of detecting missing intra-frequency neighboring
cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
InterF B SET No Non Meaning: Whether the function of detecting missing inter-
reqNC S UNC ne e frequency neighboring cells is enabled. This switch is turned on.
ellDet C ELLD The function of detecting missing inter-frequency neighboring
ectSwi 6 ETEC cells is enabled. That is, the UE reports the inter-frequency
tch 9 TSWI measurement results to the RNC and the RNC then reports the
0 TCH detected missing inter-frequency neighboring cells to the Nastar
0 or LMT. This switch is turned off. The function of detecting
missing inter-frequency neighboring cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
InterF B SET No Non Meaning: Whether the function of detecting missing inter-
reqNC S UNC ne e frequency neighboring cells is enabled. This switch is turned on.
ellDet C ELLD The function of detecting missing inter-frequency neighboring
ectSwi 6 ETEC cells is enabled. That is, the UE reports the inter-frequency
tch 9 TSWI measurement results to the RNC and the RNC then reports the
1 TCH detected missing inter-frequency neighboring cells to the Nastar
0 or LMT. This switch is turned off. The function of detecting
missing inter-frequency neighboring cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
DlSFL B SET W Inte Meaning: Whether the CM is limited by the downlink spreading
imitC S UCM RF r factor (SF). Starting the compressed mode is resource consuming
MInd C CF D- Fre for the fast-moving UEs, so this parameter is set to control
6 02 que whether the downlink SF of the current DCH channel should be
9 03 ncy considered. When this parameter is set to FALSE, the enabling
0 02 Har of CM does not consider the SF of the downlink DCH channel;
0 W d when this parameter is set to TRUE, the enabling of CM
RF Han considers the SF of the downlink DCH channel.
D- dov GUI Value Range: FALSE(Not Limited), TRUE(Limited)
02 er Unit: None
03 Bas
Actual Value Range: FALSE, TRUE
03 ed
on Default Value: FALSE(Not Limited)
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Cov
erag
e
DlSFL B SET W Inte Meaning: Whether the CM is limited by the downlink spreading
imitC S UCM RF r factor (SF). Starting the compressed mode is resource consuming
MInd C CF D- Fre for the fast-moving UEs, so this parameter is set to control
6 02 que whether the downlink SF of the current DCH channel should be
9 03 ncy considered. When this parameter is set to FALSE, the enabling
1 02 Har of CM does not consider the SF of the downlink DCH channel;
0 W d when this parameter is set to TRUE, the enabling of CM
RF Han considers the SF of the downlink DCH channel.
D- dov GUI Value Range: FALSE(Not Limited), TRUE(Limited)
02 er Unit: None
03 Bas
Actual Value Range: FALSE, TRUE
03 ed
on Default Value: FALSE(Not Limited)
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
Limit B SET W Inte Meaning: Downlink SF threshold for enabling compressed mode
CMDl S UCM RF r (CM). When the parameter "DlSFLimitCMInd" is set to TRUE
SFThd C CF D- Fre and the current downlink SF is smaller than or equal to the value
6 02 que of this parameter, the active set quality measurement is not
9 03 ncy allowed, that is, the CM cannot be enabled. When the parameter
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Limit B SET W Inte Meaning: Downlink SF threshold for enabling compressed mode
CMDl S UCM RF r (CM). When the parameter "DlSFLimitCMInd" is set to TRUE
SFThd C CF D- Fre and the current downlink SF is smaller than or equal to the value
6 02 que of this parameter, the active set quality measurement is not
9 03 ncy allowed, that is, the CM cannot be enabled. When the parameter
1 02 Har "DlSFLimitCMInd" is set to TRUE and the current downlink SF
0 W d is greater than the value of this parameter, the active set quality
RF Han measurement is allowed, that is, the CM can be enabled.
D- dov GUI Value Range: D8, D16, D32, D64, D128, D256
02 er Unit: None
03 Bas
Actual Value Range: 8, 16, 32, 64, 128, 256
03 ed
on Default Value: D8
Cov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
03 nag
05 eme
W nt
RF Inte
D- r
02 Fre
03 que
06 ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Han
dov
er
Bas
ed
on
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
03 GP Default Value:
02 RS CMCF_DL_HLS_SWITCH:1,CMCF_UL_HLS_SWITCH:1,C
W Inte MCF_UL_PRECFG_TOLERANCE_SWITCH:0,CMCF_WITH
RF r- OUT_UE_CAP_REPORT_SWITCH:0,CMCF_AVOID_DL_SF
D- RA _2_CHG_SCCODE_SWITCH:0
02 T
03 Han
03 dov
W er
RF Pha
D- se 2
02 HS
03 UP
04 A
W Mo
RF bilit
D- y
02 Ma
03 nag
05 eme
W nt
RF Inte
D- r
02 Fre
03 que
06 ncy
Har
d
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r-
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
DlSFT B ADD W Inte Meaning: Spreading factor (SF) threshold for UEs to start the
urnPoi S UCE RF r CM in the downlink in a cell. When the downlink spreading
nt C LLC D- Fre factor is greater than or equal to the value of this parameter, the
6 MCF 02 que SF/2 mode is preferred. Otherwise, the high-layer scheduling
9 MOD 03 ncy mode is preferred. The SF/2 mode consumes more system
0 UCE 02 Har resources than the high-layer scheduling mode. Therefore, this
0 LLC W d mode is recommended only for low-rate users. The high-layer
MCF RF Han scheduling mode requires variable multiplexing positions of
D- dov transport channels and is applicable to a relatively narrow range.
02 er In addition, this approach affects the transmission rate of users.
03 Bas Therefore, this mode is recommended only when the SF/2
03 ed approach is unavailable or there are high-rate users.
on GUI Value Range: D8, D16, D32, D64, D128, D256
Cov Unit: None
erag
Actual Value Range: 8, 16, 32, 64, 128, 256
e
Default Value: D64
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Cov
erag
e
DlSFT B ADD W Inte Meaning: Spreading factor (SF) threshold for UEs to start the
urnPoi S UCE RF r CM in the downlink in a cell. When the downlink spreading
nt C LLC D- Fre factor is greater than or equal to the value of this parameter, the
6 MCF 02 que SF/2 mode is preferred. Otherwise, the high-layer scheduling
9 MOD 03 ncy mode is preferred. The SF/2 mode consumes more system
1 UCE 02 Har resources than the high-layer scheduling mode. Therefore, this
0 LLC W d mode is recommended only for low-rate users. The high-layer
MCF RF Han scheduling mode requires variable multiplexing positions of
D- dov transport channels and is applicable to a relatively narrow range.
02 er In addition, this approach affects the transmission rate of users.
03 Bas Therefore, this mode is recommended only when the SF/2
03 ed approach is unavailable or there are high-rate users.
on GUI Value Range: D8, D16, D32, D64, D128, D256
Cov Unit: None
erag
Actual Value Range: 8, 16, 32, 64, 128, 256
e
Default Value: D64
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
UlSFT B ADD W Inte Meaning: SF threshold for UEs to start the CM in the uplink in a
urnPoi S UCE RF r cell. When the uplink spreading factor is greater than or equal to
nt C LLC D- Fre the value of this parameter, the SF/2 mode is preferred.
6 MCF 02 que Otherwise, the high-layer scheduling mode is preferred. The
9 MOD 03 ncy SF/2 mode consumes more system resources than the high-layer
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
0 UCE 02 Har scheduling mode. Therefore, this mode is recommended only for
0 LLC W d low-rate users. The high-layer scheduling mode requires variable
MCF RF Han multiplexing positions of transport channels and is applicable to
D- dov a relatively narrow range. In addition, this approach affects the
02 er transmission rate of users. Therefore, this mode is recommended
03 Bas only when the SF/2 approach is unavailable or there are high-rate
03 ed users.
on GUI Value Range: D8, D16, D32, D64, D128, D256
Cov Unit: None
erag
Actual Value Range: 8, 16, 32, 64, 128, 256
e
Default Value: D64
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
UlSFT B ADD W Inte Meaning: SF threshold for UEs to start the CM in the uplink in a
urnPoi S UCE RF r cell. When the uplink spreading factor is greater than or equal to
nt C LLC D- Fre the value of this parameter, the SF/2 mode is preferred.
6 MCF 02 que Otherwise, the high-layer scheduling mode is preferred. The
9 MOD 03 ncy SF/2 mode consumes more system resources than the high-layer
1 UCE 02 Har scheduling mode. Therefore, this mode is recommended only for
0 LLC W d low-rate users. The high-layer scheduling mode requires variable
MCF RF Han multiplexing positions of transport channels and is applicable to
D- dov a relatively narrow range. In addition, this approach affects the
02 er transmission rate of users. Therefore, this mode is recommended
03 Bas only when the SF/2 approach is unavailable or there are high-rate
03 ed users.
on GUI Value Range: D8, D16, D32, D64, D128, D256
Cov Unit: None
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
InterF B ADD W Inte Meaning: RAT type of the measured neighboring cell during a
reqRA S UCE RF r coverage-based handover when inter-frequency and inter-RAT
TSwit C LLH D- Fre neighboring cells are configured. When INTERFREQ is
ch 6 OCO 02 que selected, only inter-frequency neighboring cells are measured
9 MM 03 ncy and inter-frequency handover is performed. When INTERRAT is
0 MOD 02 Har selected, only neighboring GSM cells are measured and inter-
0 UCE W d RAT handover is performed. When SIMINTERFREQRAT is
LLH RF Han selected, both inter-frequency and inter-RAT cells are measured,
OCO D- dov and the handover is performed according to the type of the cell
MM 02 er that first meets the handover decision criteria. This parameter
03 Bas does not affect measurements or handovers towards a
03 ed neighboring LTE cell.
on GUI Value Range: INTERFREQ(inter-frequency handover
Cov only), INTERRAT(inter-RAT handover only),
erag SIMINTERFREQRAT(inter-frequency and inter-RAT handover)
e Unit: None
Inte Actual Value Range: INTERFREQ, INTERRAT,
r- SIMINTERFREQRAT
RA
Default Value: SIMINTERFREQRAT(inter-frequency and inter-
T
RAT handover)
Han
dov
er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Bas
ed
on
Cov
erag
e
InterF B ADD W Inte Meaning: RAT type of the measured neighboring cell during a
reqRA S UCE RF r coverage-based handover when inter-frequency and inter-RAT
TSwit C LLH D- Fre neighboring cells are configured. When INTERFREQ is
ch 6 OCO 02 que selected, only inter-frequency neighboring cells are measured
9 MM 03 ncy and inter-frequency handover is performed. When INTERRAT is
1 MOD 02 Har selected, only neighboring GSM cells are measured and inter-
0 UCE W d RAT handover is performed. When SIMINTERFREQRAT is
LLH RF Han selected, both inter-frequency and inter-RAT cells are measured,
OCO D- dov and the handover is performed according to the type of the cell
MM 02 er that first meets the handover decision criteria. This parameter
03 Bas does not affect measurements or handovers towards a
03 ed neighboring LTE cell.
on GUI Value Range: INTERFREQ(inter-frequency handover
Cov only), INTERRAT(inter-RAT handover only),
erag SIMINTERFREQRAT(inter-frequency and inter-RAT handover)
e Unit: None
Inte Actual Value Range: INTERFREQ, INTERRAT,
r- SIMINTERFREQRAT
RA
Default Value: SIMINTERFREQRAT(inter-frequency and inter-
T
RAT handover)
Han
dov
er
Bas
ed
on
Cov
erag
e
InterF B ADD W Inte Meaning: Length of the timer for the inter-frequency
reqMe S UCE RF r measurement. If the inter-frequency handover is not performed
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
asTim C LLIN D- Fre before this timer expires, the inter-frequency measurement is
e 6 TERF 02 que stopped and the compression mode is disabled (if enabled
9 REQ 03 ncy before). The value 0 indicates that this timer is not to be started.
0 HOC 02 Har This parameter is used to prevent the long duration of the inter-
0 OV W d frequency measurement state (compression mode) due to
MOD RF Han unavailability of a target cell that meets the handover criteria.
UCE D- dov GUI Value Range: 0~512
LLIN 02 er Unit: s
TERF 03 Bas
Actual Value Range: 0~512
REQ 04 ed
on Default Value: 60
HOC W
OV RF Cov
D- erag
02 e
12 Inte
00 r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
HC
S
(Hi
erar
chic
al
Cell
Stru
ctur
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
e)
InterF B ADD W Inte Meaning: Length of the timer for the inter-frequency
reqMe S UCE RF r measurement. If the inter-frequency handover is not performed
asTim C LLIN D- Fre before this timer expires, the inter-frequency measurement is
e 6 TERF 02 que stopped and the compression mode is disabled (if enabled
9 REQ 03 ncy before). The value 0 indicates that this timer is not to be started.
1 HOC 02 Har This parameter is used to prevent the long duration of the inter-
0 OV W d frequency measurement state (compression mode) due to
MOD RF Han unavailability of a target cell that meets the handover criteria.
UCE D- dov GUI Value Range: 0~512
LLIN 02 er Unit: s
TERF 03 Bas
Actual Value Range: 0~512
REQ 04 ed
on Default Value: 60
HOC W
OV RF Cov
D- erag
02 e
12 Inte
00 r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
HC
S
(Hi
erar
chic
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
al
Cell
Stru
ctur
e)
InterF B ADD W Inte Meaning: Length of the timer for the inter-frequency
reqMe S UCE RF r measurement. If the inter-frequency handover is not performed
asTim C LLIN D- Fre before this timer expires, the inter-frequency measurement is
e 6 TERF 02 que stopped and the compression mode is disabled (if enabled
9 REQ 01 ncy before). The value 0 indicates that this timer is not to be started.
0 HON 03 Loa This parameter is used to prevent the long duration of the inter-
0 COV W d frequency measurement state (compression mode) due to
MOD RF Bal unavailability of a target cell that meets the handover criteria.
UCE D- anc GUI Value Range: 0~512
LLIN 02 e Unit: s
TERF 03 Inte Actual Value Range: 0~512
REQ 02 r
Default Value: 15
HON W Fre
COV RF que
D- ncy
02 Har
03 d
04 Han
W dov
RF er
D- Bas
02 ed
12 on
00 Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Han
dov
er
Bas
ed
on
DL
Qo
S
HC
S
(Hi
erar
chic
al
Cell
Stru
ctur
e)
InterF B ADD W Inte Meaning: Length of the timer for the inter-frequency
reqMe S UCE RF r measurement. If the inter-frequency handover is not performed
asTim C LLIN D- Fre before this timer expires, the inter-frequency measurement is
e 6 TERF 02 que stopped and the compression mode is disabled (if enabled
9 REQ 01 ncy before). The value 0 indicates that this timer is not to be started.
1 HON 03 Loa This parameter is used to prevent the long duration of the inter-
0 COV W d frequency measurement state (compression mode) due to
MOD RF Bal unavailability of a target cell that meets the handover criteria.
UCE D- anc GUI Value Range: 0~512
LLIN 02 e Unit: s
TERF 03 Inte Actual Value Range: 0~512
REQ 02 r
Default Value: 15
HON W Fre
COV RF que
D- ncy
02 Har
03 d
04 Han
W dov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RF er
D- Bas
02 ed
12 on
00 Cov
erag
e
Inte
r
Fre
que
ncy
Har
d
Han
dov
er
Bas
ed
on
DL
Qo
S
HC
S
(Hi
erar
chic
al
Cell
Stru
ctur
e)
InterR B ADD W Inte Meaning: Length of a timer for inter-RAT measurements. After
ATMe S UCE RF r- the inter-RAT measurement starts, if no inter-RAT handover is
asTim C LLIN D- RA performed when this timer expires, the inter-RAT measurement
e 6 TERR 02 T is stopped. In addition, the compressed mode (if activated)
9 ATH 03 Han should be deactivated. The value 0 indicates that the inter-RAT
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er
Bas
ed
on
Loa
d
InterR B ADD W Inte Meaning: Length of a timer for inter-RAT measurements. After
ATMe S UCE RF r- the inter-RAT measurement starts, if no inter-RAT handover is
asTim C LLIN D- RA performed when this timer expires, the inter-RAT measurement
e 6 TERR 02 T is stopped. In addition, the compressed mode (if activated)
9 ATH 03 Han should be deactivated. The value 0 indicates that the inter-RAT
1 OCO 09 dov measurement timer is not started.
0 V W er GUI Value Range: 0~512
MOD RF Bas Unit: s
UCE D- ed
Actual Value Range: 0~512
LLIN 02 on
DL Default Value: 60
TERR 03
ATH 03 Qo
OCO W S
V RF Inte
D- r-
02 RA
03 T
05 Han
W dov
RF er
D- Bas
02 ed
03 on
06 Cov
erag
e
Inte
r-
RA
T
Han
dov
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
InterR B ADD W Inte Meaning: Length of a timer for inter-RAT measurements. After
ATMe S UCE RF r- the inter-RAT measurement starts, if no inter-RAT handover is
asTim C LLIN D- RA performed when this timer expires, the inter-RAT measurement
e 6 TERR 02 T is stopped. In addition, the compressed mode (if activated)
9 ATH 03 Han should be deactivated. The value 0 indicates that the inter-RAT
0 ONC 09 dov measurement timer is not started.
0 OV W er GUI Value Range: 0~512
MOD RF Bas Unit: s
UCE D- ed
Actual Value Range: 0~512
LLIN 02 on
DL Default Value: 15
TERR 03
ATH 03 Qo
ONC W S
OV RF Inte
D- r-
02 RA
03 T
05 Han
W dov
RF er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
D- Bas
02 ed
03 on
06 Cov
erag
e
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Ser
vice
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Loa
d
InterR B ADD W Inte Meaning: Length of a timer for inter-RAT measurements. After
ATMe S UCE RF r- the inter-RAT measurement starts, if no inter-RAT handover is
asTim C LLIN D- RA performed when this timer expires, the inter-RAT measurement
e 6 TERR 02 T is stopped. In addition, the compressed mode (if activated)
9 ATH 03 Han should be deactivated. The value 0 indicates that the inter-RAT
1 ONC 09 dov measurement timer is not started.
0 OV W er GUI Value Range: 0~512
MOD RF Bas Unit: s
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
on
Loa
d
DLQo B ADD W Inte Meaning: Timer length for downlink QoS measurement. This
sMcTi S UCE RF r- parameter controls the time lengths for the inter-frequency and
merLe C LLQ D- RA inter-RAT measurement based on QoS. After inter-frequency or
n 6 OSH 02 T inter-RAT measurement starts, if no inter-frequency handover is
9 O 03 Han performed when this timer expires, the measurement is stopped,
0 MOD 09 dov and the compressed mode is deactivated, if any. If this parameter
0 UCE W er is set to 0, this indicates that the timer will not be started. For the
LLQ RF Bas inter-frequency or inter-RAT measurement based on coverage,
OSH D- ed the compressed mode can be stopped through reporting event 2F.
O 02 on For measurement that is not based on coverage, event 2F is not
03 DL reported, and the timer must be set but should not be set to 0. As
04 Qo for the impact on network performance: It reduces the influence
S of long time compressed mode to the serving cell. The
Inte compressed mode may be stopped ahead of time, which can
r cause the result that the UE fails to initiate inter-frequency or
Fre inter-RAT handover, and thus can lead to call drops.
que GUI Value Range: 0~512
ncy Unit: s
Har Actual Value Range: 0~512
d
Default Value: 20
Han
dov
er
Bas
ed
on
DL
Qo
S
DLQo B ADD W Inte Meaning: Timer length for downlink QoS measurement. This
sMcTi S UCE RF r- parameter controls the time lengths for the inter-frequency and
merLe C LLQ D- RA inter-RAT measurement based on QoS. After inter-frequency or
n 6 OSH 02 T inter-RAT measurement starts, if no inter-frequency handover is
9 O 03 Han performed when this timer expires, the measurement is stopped,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
1 MOD 09 dov and the compressed mode is deactivated, if any. If this parameter
0 UCE W er is set to 0, this indicates that the timer will not be started. For the
LLQ RF Bas inter-frequency or inter-RAT measurement based on coverage,
OSH D- ed the compressed mode can be stopped through reporting event 2F.
O 02 on For measurement that is not based on coverage, event 2F is not
03 DL reported, and the timer must be set but should not be set to 0. As
04 Qo for the impact on network performance: It reduces the influence
S of long time compressed mode to the serving cell. The
Inte compressed mode may be stopped ahead of time, which can
r cause the result that the UE fails to initiate inter-frequency or
Fre inter-RAT handover, and thus can lead to call drops.
que GUI Value Range: 0~512
ncy Unit: s
Har Actual Value Range: 0~512
d
Default Value: 20
Han
dov
er
Bas
ed
on
DL
Qo
S
ULQo B ADD W Inte Meaning: Timer length for uplink QoS measurement. This
sMcTi S UCE RF r- parameter controls the time lengths for the inter-frequency and
merLe C LLQ D- RA inter-RAT measurement based on Qos. After inter-frequency or
n 6 OSH 02 T inter-RAT measurement starts, if no inter-frequency handover is
9 O 03 Han performed when this timer expires, the measurement is stopped,
0 MOD 09 dov and the compressed mode is deactivated, if any. If this parameter
0 UCE W er is set to 0, this indicates that the timer will not be started. For the
LLQ RF Bas inter-frequency or inter-RAT measurement based on coverage,
OSH D- ed the compressed mode can be stopped through reporting event 2F.
O 02 on For measurement that is not based on coverage, event 2F is not
03 DL reported, and the timer must be set but should not be set to 0. As
04 Qo for the impact on network performance: It reduces the influence
S of long time compressed mode to the serving cell. The
Inte compressed mode may be stopped ahead of time, which can
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ULQo B ADD W Inte Meaning: Timer length for uplink QoS measurement. This
sMcTi S UCE RF r- parameter controls the time lengths for the inter-frequency and
merLe C LLQ D- RA inter-RAT measurement based on Qos. After inter-frequency or
n 6 OSH 02 T inter-RAT measurement starts, if no inter-frequency handover is
9 O 03 Han performed when this timer expires, the measurement is stopped,
1 MOD 09 dov and the compressed mode is deactivated, if any. If this parameter
0 UCE W er is set to 0, this indicates that the timer will not be started. For the
LLQ RF Bas inter-frequency or inter-RAT measurement based on coverage,
OSH D- ed the compressed mode can be stopped through reporting event 2F.
O 02 on For measurement that is not based on coverage, event 2F is not
03 DL reported, and the timer must be set but should not be set to 0. As
04 Qo for the impact on network performance: It reduces the influence
S of long time compressed mode to the serving cell. The
Inte compressed mode may be stopped ahead of time, which can
r cause the result that the UE fails to initiate inter-frequency or
Fre inter-RAT handover, and thus can lead to call drops.
que GUI Value Range: 0~512
ncy Unit: s
Har Actual Value Range: 0~512
d
Default Value: 20
Han
dov
er
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Bas
ed
on
DL
Qo
S
25)PAGING_OVERLAP_CU_OPT_SWITCH(Optimize CS
Paging During Cell Update) Whether the RNC optimizes CS
paging that occurs during a cell update procedure. 1: This switch
is set to on. The RNC optimizes CS paging that occurs during a
cell update procedure. 0: This switch is set to off. The RNC does
not optimize CS paging that occurs during a cell update
procedure, and as a result, the access delay of the CS called
partly is long.
26)SRVCC_RELOC_IN_USE_CS_KEY_SWITCH(SRVCC
Incoming Relocation Using CS CK Switch) Whether UEs that
are processing CS+PS combined services use the CS cipher key
(CK) during an SRVCC incoming relocation. 1: This switch is
set to on. UEs that are processing CS+PS combined services use
the CS CK during an SRVCC incoming relocation. This prevents
relocation failures caused by incorrect CKs. 0: This switch is set
to off. UEs that are processing CS+PS combined services use the
CK of the last released domain during an SRVCC incoming
relocation. If the last released domain is PS, the incoming
relocation fails.
27)SOCKET_RECEIVE_DATA_CORRECT_SWITCH(CBC
Socket Receive Data Length Control Switch) Whether the RNC
correctly processes the messages whose size is greater than 32
kbytes and that are sent by the cell broadcast center (CBC)
server. 1: This switch is set to on. The RNC correctly processes
the messages whose size is greater than 32 Kbytes and that are
sent by the CBC server. 0: This switch is set to off. The RNC
cannot correctly process the messages whose size is greater than
32 kbytes and that are sent by the CBC server.
28)CU_PRI_OVERLAP_OTHER_PROC_SWITCH(Preferential
ly Process Cell Update in Process Overlap) Whether the RNC
preferentially processes the cell update procedure when it
overlaps with other procedures. 1: When this switch is set to on,
the RNC preferentially processes the cell update procedure in the
preceding scenario. 0: When this switch is set to off, the original
processing method is used.
29)INTERRAT2U_INTEG_PROTECT_OPT_SWITCH(Integrit
y Protection Optimization Switch for Incoming Inter-RAT
Handovers) Whether the optimized integrity protection function
is enabled for incoming L2U or G2U inter-RAT handovers. 1:
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
AMRC_ON_122_AMR_HHO_ROLL_BACK_SWITCH,
RELOC_IN_RG_COMB_INDEX_ALLOC_SWITCH,
SCM_CU_CROSS_SWITCH,
DRNC_HSPA_CM_OPT_SWITCH,
IUB_TRANSID_OPT_SWITCH,
L2_ENHENCE_RECFG_OPT_SWITCH,
ASYN_RL_REEST_OPT_SWITCH,
RNC_IMSI_HO_OPT_SWITCH,
IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWITCH,
URA_PCH_LAC_RAC_CHG_NO_PAGING_SWITCH,
PAGING_OVERLAP_CU_OPT_SWITCH,
SRVCC_RELOC_IN_USE_CS_KEY_SWITCH,
SOCKET_RECEIVE_DATA_CORRECT_SWITCH,
CU_PRI_OVERLAP_OTHER_PROC_SWITCH,
INTERRAT2U_INTEG_PROTECT_OPT_SWITCH,
INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITCH,
DRNC_RL_PARA_UPT_OPT_SWITCH
Unit: None
Actual Value Range:
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH,
RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH,
DRNC_RL_REEST_OPT_SWITCH,
URA2FACH_OVERLAP_CELLUPT_PROC_SWITCH,
RB_SETUP_F2D_USE_AM_RLC_SWITCH,
RB_RECFG_D2F_USE_AM_RLC_SWITCH,
RB_RECFG_F2D_USE_AM_RLC_SWITCH,
RRC_UE_USER_SMOOTH_OPT_SWITCH,
TRNC_LOAD_CTRL_SWITCH,
IU_SIG_REL_PCH_PAGING_SWITCH,
CPC_OPT_FOR_RLSETUP_SWITCH,
D2P_L2DEACT_FAIL_OPT_SWITCH,
EFACH_RRC_REG_CMP_SWITCH,
P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITCH,
AMRC_ON_122_AMR_HHO_ROLL_BACK_SWITCH,
RELOC_IN_RG_COMB_INDEX_ALLOC_SWITCH,
SCM_CU_CROSS_SWITCH,
DRNC_HSPA_CM_OPT_SWITCH,
IUB_TRANSID_OPT_SWITCH,
L2_ENHENCE_RECFG_OPT_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
ASYN_RL_REEST_OPT_SWITCH,
RNC_IMSI_HO_OPT_SWITCH,
IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWITCH,
URA_PCH_LAC_RAC_CHG_NO_PAGING_SWITCH,
PAGING_OVERLAP_CU_OPT_SWITCH,
SRVCC_RELOC_IN_USE_CS_KEY_SWITCH,
SOCKET_RECEIVE_DATA_CORRECT_SWITCH,
CU_PRI_OVERLAP_OTHER_PROC_SWITCH,
INTERRAT2U_INTEG_PROTECT_OPT_SWITCH,
INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITCH,
DRNC_RL_PARA_UPT_OPT_SWITCH
Default Value:
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH:0,RB_SET
UP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH:0,DRNC_R
L_REEST_OPT_SWITCH:1,URA2FACH_OVERLAP_CELLU
PT_PROC_SWITCH:0,RB_SETUP_F2D_USE_AM_RLC_SWI
TCH:0,RB_RECFG_D2F_USE_AM_RLC_SWITCH:0,RB_RE
CFG_F2D_USE_AM_RLC_SWITCH:0,RRC_UE_USER_SMO
OTH_OPT_SWITCH:1,TRNC_LOAD_CTRL_SWITCH:0,IU_
SIG_REL_PCH_PAGING_SWITCH:0,CPC_OPT_FOR_RLSE
TUP_SWITCH:1,D2P_L2DEACT_FAIL_OPT_SWITCH:0,EF
ACH_RRC_REG_CMP_SWITCH:0,P2D_TSID_ERR_UE_RSP
_MSG_DISCD_SWITCH:0,AMRC_ON_122_AMR_HHO_RO
LL_BACK_SWITCH:0,RELOC_IN_RG_COMB_INDEX_ALL
OC_SWITCH:0,SCM_CU_CROSS_SWITCH:0,DRNC_HSPA_
CM_OPT_SWITCH:0,IUB_TRANSID_OPT_SWITCH:0,L2_E
NHENCE_RECFG_OPT_SWITCH:0,ASYN_RL_REEST_OPT
_SWITCH:0,RNC_IMSI_HO_OPT_SWITCH:0,IUR_PRIQUE
UE_INFO_TO_MODIFY_OPT_SWITCH:0,URA_PCH_LAC_
RAC_CHG_NO_PAGING_SWITCH:0,PAGING_OVERLAP_C
U_OPT_SWITCH:0,SRVCC_RELOC_IN_USE_CS_KEY_SWI
TCH:1,SOCKET_RECEIVE_DATA_CORRECT_SWITCH:1,C
U_PRI_OVERLAP_OTHER_PROC_SWITCH:0,INTERRAT2
U_INTEG_PROTECT_OPT_SWITCH:0,INTRA_NODEB_RL
CC_INIT_CAP_OPT_SWITCH:0,DRNC_RL_PARA_UPT_OP
T_SWITCH:1
Switc C CTRL sh TRB RLC in AM for RL Reestablish) When radio link (RL)
h4 6 SWIT reestablishment is triggered during RB related procedures, the
9 CH encryption parameters configured for the RNC become
1 inconsistent with those configured for the UE if the following
0 conditions are met: The RB related procedure succeeds; the TRB
is in acknowledged mode (AM) or the size of the RLC PDU
changes in AM; the RLC entity is not reestablished for the TRB.
As a result, data transmission fails on the user plane, and the
TRB is reset. This parameter specifies whether the RNC
reestablishes the RLC entity for TRBs that use AM in the
preceding scenario. 1: This switch is turned on. The RLC entity
is reestablished for the TRB in the preceding scenario. 0: This
switch is turned off. The RLC entity is not reestablished for the
TRB in the preceding scenario.
2)RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH(
Optimize RL Reestablishment for UM TRB) When RL
reestablishment is triggered during an RB setup procedure in
unacknowledged mode (UM), the encryption parameters for the
RNC and UE cannot be reconfigured. As a result, after the RL is
reestablished, data transmission fails on the user plane because
the encryption parameters configured for the RNC are
inconsistent with those configured for the UE. Services are
interrupted. This parameter specifies whether the RNC
reestablishes the RL for TRBs that use UM in the preceding
scenario. 1: This switch is turned on. If the TRB has been
established for the UE, RL reestablishment is not performed in
the preceding scenario even if its trigger conditions are met. 0:
This switch is turned off. RL reestablishment is performed in the
preceding scenario when its trigger conditions are met.
3)DRNC_RL_REEST_OPT_SWITCH(DRNC RL
Reestablishment Optimization Switch) Whether the RNC
receives a complete message from the UE during radio link (RL)
reestablishment over the Iur interface. 1: This switch is turned
on. The RNC receives a complete message from the UE in the
preceding scenario. 0: This switch is turned off. The RNC does
not receive a complete message from the UE in the preceding
scenario.
4)URA2FACH_OVERLAP_CELLUPT_PROC_SWITCH
Whether the RAN processes a cell update procedure caused by
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
23)IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWITCH(Opt
imize the priorityQueue-Info-to-Modify IE in RADIO LINK
RECONFIGURATION PREPARE Messages over Iur) Whether
the RADIO LINK RECONFIGURATION PREPARE message
over the Iur interface carries the MAChsGuaranteedBitRate or
DiscardTimer field in the priorityQueue-Info-to-Modify IE when
the field will remain unchanged after the reconfiguration. 1: This
switch is set to on. the RADIO LINK RECONFIGURATION
PREPARE message over the Iur interface carries the
MAChsGuaranteedBitRate or DiscardTimer field in the
priorityQueue-Info-to-Modify IE when the field will remain
unchanged after the reconfiguration. In this case, the DRNC can
successfully reinitiate a relocation process after a UE of Release
6 and earlier versions whose SRB is carried on an HSDPA
channel is relocated to the DRNC. 0: This switch is set to off. the
RADIO LINK RECONFIGURATION PREPARE message over
the Iur interface does not carry the priorityQueue-Info-to-Modify
IE when MAChsGuaranteedBitRate and DiscardTimer remain
unchanged after the reconfiguration. In this case, a UE of
Release 6 and earlier versions whose SRB is carried on an
HSDPA channel fails to reinitiate a relocation process after being
relocated to the DRNC.
24)URA_PCH_LAC_RAC_CHG_NO_PAGING_SWITCH (No
Paging Switch for LAC or SAC Change During URA Update)
Whether paging is performed when the location area code (LAC)
or service area code (SAC) of the target cell differs from that of
the source cell during a UTRAN registration area (URA) update.
1: This switch is set to on. Paging is not performed in the
preceding scenario. 0: This switch is set to off. Paging is
performed in the preceding scenario.
25)PAGING_OVERLAP_CU_OPT_SWITCH(Optimize CS
Paging During Cell Update) Whether the RNC optimizes CS
paging that occurs during a cell update procedure. 1: This switch
is set to on. The RNC optimizes CS paging that occurs during a
cell update procedure. 0: This switch is set to off. The RNC does
not optimize CS paging that occurs during a cell update
procedure, and as a result, the access delay of the CS called
partly is long.
26)SRVCC_RELOC_IN_USE_CS_KEY_SWITCH(SRVCC
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
URA_PCH_LAC_RAC_CHG_NO_PAGING_SWITCH,
PAGING_OVERLAP_CU_OPT_SWITCH,
SRVCC_RELOC_IN_USE_CS_KEY_SWITCH,
SOCKET_RECEIVE_DATA_CORRECT_SWITCH,
CU_PRI_OVERLAP_OTHER_PROC_SWITCH,
INTERRAT2U_INTEG_PROTECT_OPT_SWITCH,
INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITCH,
DRNC_RL_PARA_UPT_OPT_SWITCH
Unit: None
Actual Value Range:
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH,
RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH,
DRNC_RL_REEST_OPT_SWITCH,
URA2FACH_OVERLAP_CELLUPT_PROC_SWITCH,
RB_SETUP_F2D_USE_AM_RLC_SWITCH,
RB_RECFG_D2F_USE_AM_RLC_SWITCH,
RB_RECFG_F2D_USE_AM_RLC_SWITCH,
RRC_UE_USER_SMOOTH_OPT_SWITCH,
TRNC_LOAD_CTRL_SWITCH,
IU_SIG_REL_PCH_PAGING_SWITCH,
CPC_OPT_FOR_RLSETUP_SWITCH,
D2P_L2DEACT_FAIL_OPT_SWITCH,
EFACH_RRC_REG_CMP_SWITCH,
P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITCH,
AMRC_ON_122_AMR_HHO_ROLL_BACK_SWITCH,
RELOC_IN_RG_COMB_INDEX_ALLOC_SWITCH,
SCM_CU_CROSS_SWITCH,
DRNC_HSPA_CM_OPT_SWITCH,
IUB_TRANSID_OPT_SWITCH,
L2_ENHENCE_RECFG_OPT_SWITCH,
ASYN_RL_REEST_OPT_SWITCH,
RNC_IMSI_HO_OPT_SWITCH,
IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWITCH,
URA_PCH_LAC_RAC_CHG_NO_PAGING_SWITCH,
PAGING_OVERLAP_CU_OPT_SWITCH,
SRVCC_RELOC_IN_USE_CS_KEY_SWITCH,
SOCKET_RECEIVE_DATA_CORRECT_SWITCH,
CU_PRI_OVERLAP_OTHER_PROC_SWITCH,
INTERRAT2U_INTEG_PROTECT_OPT_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITCH,
DRNC_RL_PARA_UPT_OPT_SWITCH
Default Value:
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH:0,RB_SET
UP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH:0,DRNC_R
L_REEST_OPT_SWITCH:1,URA2FACH_OVERLAP_CELLU
PT_PROC_SWITCH:0,RB_SETUP_F2D_USE_AM_RLC_SWI
TCH:0,RB_RECFG_D2F_USE_AM_RLC_SWITCH:0,RB_RE
CFG_F2D_USE_AM_RLC_SWITCH:0,RRC_UE_USER_SMO
OTH_OPT_SWITCH:1,TRNC_LOAD_CTRL_SWITCH:0,IU_
SIG_REL_PCH_PAGING_SWITCH:0,CPC_OPT_FOR_RLSE
TUP_SWITCH:1,D2P_L2DEACT_FAIL_OPT_SWITCH:0,EF
ACH_RRC_REG_CMP_SWITCH:0,P2D_TSID_ERR_UE_RSP
_MSG_DISCD_SWITCH:0,AMRC_ON_122_AMR_HHO_RO
LL_BACK_SWITCH:0,RELOC_IN_RG_COMB_INDEX_ALL
OC_SWITCH:0,SCM_CU_CROSS_SWITCH:0,DRNC_HSPA_
CM_OPT_SWITCH:0,IUB_TRANSID_OPT_SWITCH:0,L2_E
NHENCE_RECFG_OPT_SWITCH:0,ASYN_RL_REEST_OPT
_SWITCH:0,RNC_IMSI_HO_OPT_SWITCH:0,IUR_PRIQUE
UE_INFO_TO_MODIFY_OPT_SWITCH:0,URA_PCH_LAC_
RAC_CHG_NO_PAGING_SWITCH:0,PAGING_OVERLAP_C
U_OPT_SWITCH:0,SRVCC_RELOC_IN_USE_CS_KEY_SWI
TCH:1,SOCKET_RECEIVE_DATA_CORRECT_SWITCH:1,C
U_PRI_OVERLAP_OTHER_PROC_SWITCH:0,INTERRAT2
U_INTEG_PROTECT_OPT_SWITCH:0,INTRA_NODEB_RL
CC_INIT_CAP_OPT_SWITCH:0,DRNC_RL_PARA_UPT_OP
T_SWITCH:1
RNC_NODE_REDUNDANCY_COMPATIBLE_SWITCH:0,HS
DPA_IE_COMPATIBLE_SWITCH:0,NRNC_COMPATIBLE_S
WITCH:0
command. 0: This switch is set to off. The NRNC does not need
compatibility processing.
GUI Value Range:
RNC_NODE_REDUNDANCY_COMPATIBLE_SWITCH(RN
C_NODE_REDUNDANCY_COMPATIBLE_SWITCH),
HSDPA_IE_COMPATIBLE_SWITCH(HSDPA_IE_COMPATIB
LE_SWITCH),
NRNC_COMPATIBLE_SWITCH(NRNC_COMPATIBLE_SWI
TCH)
Unit: None
Actual Value Range:
RNC_NODE_REDUNDANCY_COMPATIBLE_SWITCH,
HSDPA_IE_COMPATIBLE_SWITCH,
NRNC_COMPATIBLE_SWITCH
Default Value:
RNC_NODE_REDUNDANCY_COMPATIBLE_SWITCH:0,HS
DPA_IE_COMPATIBLE_SWITCH:0,NRNC_COMPATIBLE_S
WITCH:0
RsvS B SET No Non Meaning: RRM algorithm reserved U32 Switch Para 5. The 32-
witch5 S UAL ne e bit parameter is reserved for further change request use. Disuse
C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
0 parameter is not recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_5_BIT1,
RESERVED_SWITCH_5_BIT2,
RESERVED_SWITCH_5_BIT3,
RESERVED_SWITCH_5_BIT4,
RESERVED_SWITCH_5_BIT5,
RESERVED_SWITCH_5_BIT6,
RESERVED_SWITCH_5_BIT7,
RESERVED_SWITCH_5_BIT8,
RESERVED_SWITCH_5_BIT9,
RESERVED_SWITCH_5_BIT10,
RESERVED_SWITCH_5_BIT11,
RESERVED_SWITCH_5_BIT12,
RESERVED_SWITCH_5_BIT13,
RESERVED_SWITCH_5_BIT14,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_5_BIT15,
RESERVED_SWITCH_5_BIT16,
RESERVED_SWITCH_5_BIT17,
RESERVED_SWITCH_5_BIT18,
RESERVED_SWITCH_5_BIT19,
RESERVED_SWITCH_5_BIT20,
RESERVED_SWITCH_5_BIT21,
RESERVED_SWITCH_5_BIT22,
RESERVED_SWITCH_5_BIT23,
RESERVED_SWITCH_5_BIT24,
RESERVED_SWITCH_5_BIT25,
RESERVED_SWITCH_5_BIT26,
RESERVED_SWITCH_5_BIT27,
RESERVED_SWITCH_5_BIT28,
RESERVED_SWITCH_5_BIT29,
RESERVED_SWITCH_5_BIT30,
RESERVED_SWITCH_5_BIT31,
RESERVED_SWITCH_5_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_5_BIT1,
RESERVED_SWITCH_5_BIT2,
RESERVED_SWITCH_5_BIT3,
RESERVED_SWITCH_5_BIT4,
RESERVED_SWITCH_5_BIT5,
RESERVED_SWITCH_5_BIT6,
RESERVED_SWITCH_5_BIT7,
RESERVED_SWITCH_5_BIT8,
RESERVED_SWITCH_5_BIT9,
RESERVED_SWITCH_5_BIT10,
RESERVED_SWITCH_5_BIT11,
RESERVED_SWITCH_5_BIT12,
RESERVED_SWITCH_5_BIT13,
RESERVED_SWITCH_5_BIT14,
RESERVED_SWITCH_5_BIT15,
RESERVED_SWITCH_5_BIT16,
RESERVED_SWITCH_5_BIT17,
RESERVED_SWITCH_5_BIT18,
RESERVED_SWITCH_5_BIT19,
RESERVED_SWITCH_5_BIT20,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_5_BIT21,
RESERVED_SWITCH_5_BIT22,
RESERVED_SWITCH_5_BIT23,
RESERVED_SWITCH_5_BIT24,
RESERVED_SWITCH_5_BIT25,
RESERVED_SWITCH_5_BIT26,
RESERVED_SWITCH_5_BIT27,
RESERVED_SWITCH_5_BIT28,
RESERVED_SWITCH_5_BIT29,
RESERVED_SWITCH_5_BIT30,
RESERVED_SWITCH_5_BIT31,
RESERVED_SWITCH_5_BIT32
Default Value:
RESERVED_SWITCH_5_BIT1:1,RESERVED_SWITCH_5_BI
T2:1,RESERVED_SWITCH_5_BIT3:1,RESERVED_SWITCH_
5_BIT4:1,RESERVED_SWITCH_5_BIT5:1,RESERVED_SWI
TCH_5_BIT6:1,RESERVED_SWITCH_5_BIT7:1,RESERVED
_SWITCH_5_BIT8:1,RESERVED_SWITCH_5_BIT9:1,RESER
VED_SWITCH_5_BIT10:1,RESERVED_SWITCH_5_BIT11:1,
RESERVED_SWITCH_5_BIT12:1,RESERVED_SWITCH_5_B
IT13:1,RESERVED_SWITCH_5_BIT14:1,RESERVED_SWIT
CH_5_BIT15:1,RESERVED_SWITCH_5_BIT16:1,RESERVED
_SWITCH_5_BIT17:1,RESERVED_SWITCH_5_BIT18:1,RES
ERVED_SWITCH_5_BIT19:1,RESERVED_SWITCH_5_BIT2
0:1,RESERVED_SWITCH_5_BIT21:1,RESERVED_SWITCH_
5_BIT22:1,RESERVED_SWITCH_5_BIT23:1,RESERVED_S
WITCH_5_BIT24:1,RESERVED_SWITCH_5_BIT25:1,RESER
VED_SWITCH_5_BIT26:1,RESERVED_SWITCH_5_BIT27:1,
RESERVED_SWITCH_5_BIT28:1,RESERVED_SWITCH_5_B
IT29:1,RESERVED_SWITCH_5_BIT30:1,RESERVED_SWIT
CH_5_BIT31:1,RESERVED_SWITCH_5_BIT32:1
RsvS B SET No Non Meaning: RRM algorithm reserved U32 Switch Para 5. The 32-
witch5 S UAL ne e bit parameter is reserved for further change request use. Disuse
C GOR statement: This parameter is used temporarily in patch versions
6 SVPA and will be replaced with a new parameter in later versions. The
9 RA new parameter ID reflects the parameter function. Therefore, this
1 parameter is not recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_5_BIT1,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_5_BIT2,
RESERVED_SWITCH_5_BIT3,
RESERVED_SWITCH_5_BIT4,
RESERVED_SWITCH_5_BIT5,
RESERVED_SWITCH_5_BIT6,
RESERVED_SWITCH_5_BIT7,
RESERVED_SWITCH_5_BIT8,
RESERVED_SWITCH_5_BIT9,
RESERVED_SWITCH_5_BIT10,
RESERVED_SWITCH_5_BIT11,
RESERVED_SWITCH_5_BIT12,
RESERVED_SWITCH_5_BIT13,
RESERVED_SWITCH_5_BIT14,
RESERVED_SWITCH_5_BIT15,
RESERVED_SWITCH_5_BIT16,
RESERVED_SWITCH_5_BIT17,
RESERVED_SWITCH_5_BIT18,
RESERVED_SWITCH_5_BIT19,
RESERVED_SWITCH_5_BIT20,
RESERVED_SWITCH_5_BIT21,
RESERVED_SWITCH_5_BIT22,
RESERVED_SWITCH_5_BIT23,
RESERVED_SWITCH_5_BIT24,
RESERVED_SWITCH_5_BIT25,
RESERVED_SWITCH_5_BIT26,
RESERVED_SWITCH_5_BIT27,
RESERVED_SWITCH_5_BIT28,
RESERVED_SWITCH_5_BIT29,
RESERVED_SWITCH_5_BIT30,
RESERVED_SWITCH_5_BIT31,
RESERVED_SWITCH_5_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_5_BIT1,
RESERVED_SWITCH_5_BIT2,
RESERVED_SWITCH_5_BIT3,
RESERVED_SWITCH_5_BIT4,
RESERVED_SWITCH_5_BIT5,
RESERVED_SWITCH_5_BIT6,
RESERVED_SWITCH_5_BIT7,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_5_BIT8,
RESERVED_SWITCH_5_BIT9,
RESERVED_SWITCH_5_BIT10,
RESERVED_SWITCH_5_BIT11,
RESERVED_SWITCH_5_BIT12,
RESERVED_SWITCH_5_BIT13,
RESERVED_SWITCH_5_BIT14,
RESERVED_SWITCH_5_BIT15,
RESERVED_SWITCH_5_BIT16,
RESERVED_SWITCH_5_BIT17,
RESERVED_SWITCH_5_BIT18,
RESERVED_SWITCH_5_BIT19,
RESERVED_SWITCH_5_BIT20,
RESERVED_SWITCH_5_BIT21,
RESERVED_SWITCH_5_BIT22,
RESERVED_SWITCH_5_BIT23,
RESERVED_SWITCH_5_BIT24,
RESERVED_SWITCH_5_BIT25,
RESERVED_SWITCH_5_BIT26,
RESERVED_SWITCH_5_BIT27,
RESERVED_SWITCH_5_BIT28,
RESERVED_SWITCH_5_BIT29,
RESERVED_SWITCH_5_BIT30,
RESERVED_SWITCH_5_BIT31,
RESERVED_SWITCH_5_BIT32
Default Value:
RESERVED_SWITCH_5_BIT1:1,RESERVED_SWITCH_5_BI
T2:1,RESERVED_SWITCH_5_BIT3:1,RESERVED_SWITCH_
5_BIT4:1,RESERVED_SWITCH_5_BIT5:1,RESERVED_SWI
TCH_5_BIT6:1,RESERVED_SWITCH_5_BIT7:1,RESERVED
_SWITCH_5_BIT8:1,RESERVED_SWITCH_5_BIT9:1,RESER
VED_SWITCH_5_BIT10:1,RESERVED_SWITCH_5_BIT11:1,
RESERVED_SWITCH_5_BIT12:1,RESERVED_SWITCH_5_B
IT13:1,RESERVED_SWITCH_5_BIT14:1,RESERVED_SWIT
CH_5_BIT15:1,RESERVED_SWITCH_5_BIT16:1,RESERVED
_SWITCH_5_BIT17:1,RESERVED_SWITCH_5_BIT18:1,RES
ERVED_SWITCH_5_BIT19:1,RESERVED_SWITCH_5_BIT2
0:1,RESERVED_SWITCH_5_BIT21:1,RESERVED_SWITCH_
5_BIT22:1,RESERVED_SWITCH_5_BIT23:1,RESERVED_S
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
WITCH_5_BIT24:1,RESERVED_SWITCH_5_BIT25:1,RESER
VED_SWITCH_5_BIT26:1,RESERVED_SWITCH_5_BIT27:1,
RESERVED_SWITCH_5_BIT28:1,RESERVED_SWITCH_5_B
IT29:1,RESERVED_SWITCH_5_BIT30:1,RESERVED_SWIT
CH_5_BIT31:1,RESERVED_SWITCH_5_BIT32:1
RSVS B SET No Non Meaning: Reserved Switch 0. The para reserved for further
WITC S UNR ne e change request use. Disuse statement: This parameter is used
H0 C NCR temporarily in patch versions and will be replaced with a new
6 SVPA parameter in later versions. The new parameter ID reflects the
9 RA parameter function. Therefore, this parameter is not
0 recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_0_BIT1,
RESERVED_SWITCH_0_BIT2,
RESERVED_SWITCH_0_BIT3,
RESERVED_SWITCH_0_BIT4,
RESERVED_SWITCH_0_BIT5,
RESERVED_SWITCH_0_BIT6,
RESERVED_SWITCH_0_BIT7,
RESERVED_SWITCH_0_BIT8,
RESERVED_SWITCH_0_BIT9,
RESERVED_SWITCH_0_BIT10,
RESERVED_SWITCH_0_BIT11,
RESERVED_SWITCH_0_BIT12,
RESERVED_SWITCH_0_BIT13,
RESERVED_SWITCH_0_BIT14,
RESERVED_SWITCH_0_BIT15,
RESERVED_SWITCH_0_BIT16,
RESERVED_SWITCH_0_BIT17,
RESERVED_SWITCH_0_BIT18,
RESERVED_SWITCH_0_BIT19,
RESERVED_SWITCH_0_BIT20,
RESERVED_SWITCH_0_BIT21,
RESERVED_SWITCH_0_BIT22,
RESERVED_SWITCH_0_BIT23,
RESERVED_SWITCH_0_BIT24,
RESERVED_SWITCH_0_BIT25,
RESERVED_SWITCH_0_BIT26,
RESERVED_SWITCH_0_BIT27,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT28,
RESERVED_SWITCH_0_BIT29,
RESERVED_SWITCH_0_BIT30,
RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_0_BIT1,
RESERVED_SWITCH_0_BIT2,
RESERVED_SWITCH_0_BIT3,
RESERVED_SWITCH_0_BIT4,
RESERVED_SWITCH_0_BIT5,
RESERVED_SWITCH_0_BIT6,
RESERVED_SWITCH_0_BIT7,
RESERVED_SWITCH_0_BIT8,
RESERVED_SWITCH_0_BIT9,
RESERVED_SWITCH_0_BIT10,
RESERVED_SWITCH_0_BIT11,
RESERVED_SWITCH_0_BIT12,
RESERVED_SWITCH_0_BIT13,
RESERVED_SWITCH_0_BIT14,
RESERVED_SWITCH_0_BIT15,
RESERVED_SWITCH_0_BIT16,
RESERVED_SWITCH_0_BIT17,
RESERVED_SWITCH_0_BIT18,
RESERVED_SWITCH_0_BIT19,
RESERVED_SWITCH_0_BIT20,
RESERVED_SWITCH_0_BIT21,
RESERVED_SWITCH_0_BIT22,
RESERVED_SWITCH_0_BIT23,
RESERVED_SWITCH_0_BIT24,
RESERVED_SWITCH_0_BIT25,
RESERVED_SWITCH_0_BIT26,
RESERVED_SWITCH_0_BIT27,
RESERVED_SWITCH_0_BIT28,
RESERVED_SWITCH_0_BIT29,
RESERVED_SWITCH_0_BIT30,
RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Default Value:
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT1:0,RESERVED_SWITCH_0_BI
T2:0,RESERVED_SWITCH_0_BIT3:0,RESERVED_SWITCH_
0_BIT4:0,RESERVED_SWITCH_0_BIT5:0,RESERVED_SWI
TCH_0_BIT6:0,RESERVED_SWITCH_0_BIT7:0,RESERVED
_SWITCH_0_BIT8:0,RESERVED_SWITCH_0_BIT9:0,RESER
VED_SWITCH_0_BIT10:0,RESERVED_SWITCH_0_BIT11:0,
RESERVED_SWITCH_0_BIT12:0,RESERVED_SWITCH_0_B
IT13:0,RESERVED_SWITCH_0_BIT14:0,RESERVED_SWIT
CH_0_BIT15:0,RESERVED_SWITCH_0_BIT16:0,RESERVED
_SWITCH_0_BIT17:0,RESERVED_SWITCH_0_BIT18:0,RES
ERVED_SWITCH_0_BIT19:0,RESERVED_SWITCH_0_BIT2
0:0,RESERVED_SWITCH_0_BIT21:0,RESERVED_SWITCH_
0_BIT22:0,RESERVED_SWITCH_0_BIT23:0,RESERVED_S
WITCH_0_BIT24:0,RESERVED_SWITCH_0_BIT25:0,RESER
VED_SWITCH_0_BIT26:0,RESERVED_SWITCH_0_BIT27:0,
RESERVED_SWITCH_0_BIT28:0,RESERVED_SWITCH_0_B
IT29:0,RESERVED_SWITCH_0_BIT30:0,RESERVED_SWIT
CH_0_BIT31:0,RESERVED_SWITCH_0_BIT32:0
RSVS B SET No Non Meaning: Reserved Switch 0. The para reserved for further
WITC S UNR ne e change request use. Disuse statement: This parameter is used
H0 C NCR temporarily in patch versions and will be replaced with a new
6 SVPA parameter in later versions. The new parameter ID reflects the
9 RA parameter function. Therefore, this parameter is not
1 recommended for the configuration interface.
0 GUI Value Range: RESERVED_SWITCH_0_BIT1,
RESERVED_SWITCH_0_BIT2,
RESERVED_SWITCH_0_BIT3,
RESERVED_SWITCH_0_BIT4,
RESERVED_SWITCH_0_BIT5,
RESERVED_SWITCH_0_BIT6,
RESERVED_SWITCH_0_BIT7,
RESERVED_SWITCH_0_BIT8,
RESERVED_SWITCH_0_BIT9,
RESERVED_SWITCH_0_BIT10,
RESERVED_SWITCH_0_BIT11,
RESERVED_SWITCH_0_BIT12,
RESERVED_SWITCH_0_BIT13,
RESERVED_SWITCH_0_BIT14,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT15,
RESERVED_SWITCH_0_BIT16,
RESERVED_SWITCH_0_BIT17,
RESERVED_SWITCH_0_BIT18,
RESERVED_SWITCH_0_BIT19,
RESERVED_SWITCH_0_BIT20,
RESERVED_SWITCH_0_BIT21,
RESERVED_SWITCH_0_BIT22,
RESERVED_SWITCH_0_BIT23,
RESERVED_SWITCH_0_BIT24,
RESERVED_SWITCH_0_BIT25,
RESERVED_SWITCH_0_BIT26,
RESERVED_SWITCH_0_BIT27,
RESERVED_SWITCH_0_BIT28,
RESERVED_SWITCH_0_BIT29,
RESERVED_SWITCH_0_BIT30,
RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_0_BIT1,
RESERVED_SWITCH_0_BIT2,
RESERVED_SWITCH_0_BIT3,
RESERVED_SWITCH_0_BIT4,
RESERVED_SWITCH_0_BIT5,
RESERVED_SWITCH_0_BIT6,
RESERVED_SWITCH_0_BIT7,
RESERVED_SWITCH_0_BIT8,
RESERVED_SWITCH_0_BIT9,
RESERVED_SWITCH_0_BIT10,
RESERVED_SWITCH_0_BIT11,
RESERVED_SWITCH_0_BIT12,
RESERVED_SWITCH_0_BIT13,
RESERVED_SWITCH_0_BIT14,
RESERVED_SWITCH_0_BIT15,
RESERVED_SWITCH_0_BIT16,
RESERVED_SWITCH_0_BIT17,
RESERVED_SWITCH_0_BIT18,
RESERVED_SWITCH_0_BIT19,
RESERVED_SWITCH_0_BIT20,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
RESERVED_SWITCH_0_BIT21,
RESERVED_SWITCH_0_BIT22,
RESERVED_SWITCH_0_BIT23,
RESERVED_SWITCH_0_BIT24,
RESERVED_SWITCH_0_BIT25,
RESERVED_SWITCH_0_BIT26,
RESERVED_SWITCH_0_BIT27,
RESERVED_SWITCH_0_BIT28,
RESERVED_SWITCH_0_BIT29,
RESERVED_SWITCH_0_BIT30,
RESERVED_SWITCH_0_BIT31,
RESERVED_SWITCH_0_BIT32
Default Value:
RESERVED_SWITCH_0_BIT1:0,RESERVED_SWITCH_0_BI
T2:0,RESERVED_SWITCH_0_BIT3:0,RESERVED_SWITCH_
0_BIT4:0,RESERVED_SWITCH_0_BIT5:0,RESERVED_SWI
TCH_0_BIT6:0,RESERVED_SWITCH_0_BIT7:0,RESERVED
_SWITCH_0_BIT8:0,RESERVED_SWITCH_0_BIT9:0,RESER
VED_SWITCH_0_BIT10:0,RESERVED_SWITCH_0_BIT11:0,
RESERVED_SWITCH_0_BIT12:0,RESERVED_SWITCH_0_B
IT13:0,RESERVED_SWITCH_0_BIT14:0,RESERVED_SWIT
CH_0_BIT15:0,RESERVED_SWITCH_0_BIT16:0,RESERVED
_SWITCH_0_BIT17:0,RESERVED_SWITCH_0_BIT18:0,RES
ERVED_SWITCH_0_BIT19:0,RESERVED_SWITCH_0_BIT2
0:0,RESERVED_SWITCH_0_BIT21:0,RESERVED_SWITCH_
0_BIT22:0,RESERVED_SWITCH_0_BIT23:0,RESERVED_S
WITCH_0_BIT24:0,RESERVED_SWITCH_0_BIT25:0,RESER
VED_SWITCH_0_BIT26:0,RESERVED_SWITCH_0_BIT27:0,
RESERVED_SWITCH_0_BIT28:0,RESERVED_SWITCH_0_B
IT29:0,RESERVED_SWITCH_0_BIT30:0,RESERVED_SWIT
CH_0_BIT31:0,RESERVED_SWITCH_0_BIT32:0
Hsdpa B SET W HS Meaning: Whether the compressed mode (CM) can be activated
CMPe S UCM RF UP when an HSDPA service is in progress and whether an HSDPA
rmissi C CF D- A service can be set up when the CM is active. If this parameter is
onInd 6 01 Mo set to TRUE: 1. the RNC can enable the CM for HSDPA
9 06 bilit services. 2. The HSDPA services can be enabled when the CM is
0 12 y enabled. If this parameter is set to FALSE: 1. the CM for HSDPA
0 04 Ma services can be enabled only after the H2D (HS-DSCH to DCH)
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Hsdpa B SET W HS Meaning: Whether the compressed mode (CM) can be activated
CMPe S UCM RF UP when an HSDPA service is in progress and whether an HSDPA
rmissi C CF D- A service can be set up when the CM is active. If this parameter is
onInd 6 01 Mo set to TRUE: 1. the RNC can enable the CM for HSDPA
9 06 bilit services. 2. The HSDPA services can be enabled when the CM is
1 12 y enabled. If this parameter is set to FALSE: 1. the CM for HSDPA
0 04 Ma services can be enabled only after the H2D (HS-DSCH to DCH)
W nag channel switch. 2. The HSDPA services cannot be enabled when
RF eme the CM is enabled. This switch is used for the compatibility of
D- nt the HSDPA terminals that do not support CM when HSDPA is
02 Inte enabled.
03 r- GUI Value Range: FALSE(Forbidden), TRUE(Permit)
06 RA Unit: None
T Actual Value Range: FALSE, TRUE
Han
Default Value: TRUE(Permit)
dov
er
Bas
ed
on
Loa
d
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Hsupa B SET W HS Meaning: Whether the compressed mode (CM) can be activated
CMPe S UCM RF DP when an HSUPA service is in progress and whether an HSUPA
rmissi C CF D- A service can be set up when the CM is active. If this parameter is
onInd 6 01 Mo set to Permit: 1. the RNC can enable the CM for HSUPA
9 06 bilit services. 2. The HSUPA services can be enabled when the CM is
0 10 y enabled. If this parameter is set to Limited: 1. the CM for
0 06 Ma HSUPA services can be enabled only after the E2D (E-DCH to
W nag DCH) channel switch. 2. The HSUPA services cannot be enabled
RF eme when the CM is enabled. If this parameter is set to
D- nt BasedonUECap, the RNC determines whether CM can be
02 Inte enabled for HSUPA services and whether HSUPA services can
03 r- be enabled when the CM is enabled by considering the UE
06 RA capability. This switch is used for the compatibility of the
T HSUPA terminals that do not support CM when HSUPA is
Han enabled.
dov GUI Value Range: Limited(Limited), Permit(Permit),
er BasedOnUECap(Based On UE Capability)
Bas Unit: None
ed Actual Value Range: Limited, Permit, BasedOnUECap
on
Default Value: BasedOnUECap(Based On UE Capability)
Loa
d
Hsupa B SET W HS Meaning: Whether the compressed mode (CM) can be activated
CMPe S UCM RF DP when an HSUPA service is in progress and whether an HSUPA
rmissi C CF D- A service can be set up when the CM is active. If this parameter is
onInd 6 01 Mo set to Permit: 1. the RNC can enable the CM for HSUPA
9 06 bilit services. 2. The HSUPA services can be enabled when the CM is
1 10 y enabled. If this parameter is set to Limited: 1. the CM for
0 06 Ma HSUPA services can be enabled only after the E2D (E-DCH to
W nag DCH) channel switch. 2. The HSUPA services cannot be enabled
RF eme when the CM is enabled. If this parameter is set to
D- nt BasedonUECap, the RNC determines whether CM can be
02 Inte enabled for HSUPA services and whether HSUPA services can
03 r- be enabled when the CM is enabled by considering the UE
06 RA capability. This switch is used for the compatibility of the
T HSUPA terminals that do not support CM when HSUPA is
Han enabled.
dov GUI Value Range: Limited(Limited), Permit(Permit),
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
er BasedOnUECap(Based On UE Capability)
Bas Unit: None
ed Actual Value Range: Limited, Permit, BasedOnUECap
on
Default Value: BasedOnUECap(Based On UE Capability)
Loa
d
EHSP B SET W Inte Meaning: Whether the compressed mode (CM) can be activated
ACM S UCM RF r when an HSPA+ service is in progress and whether an HSPA+
Permi C CF D- Fre service can be set up when the CM is active. If this parameter is
ssionI 6 02 que set to TRUE: 1. the RNC can enable the CM for HSPA+
nd 9 03 ncy services. 2. The HSPA+ services can be enabled when the CM is
0 02 Har enabled. If this parameter is set to FALSE: 1. the CM for HSPA+
0 W d services can be enabled only after the uplink E2D (E-DCH to
RF Han DCH) and downlink H2D (HS-DSCH to DCH) channel switch.
D- dov 2. The HSPA+ services cannot be enabled when the CM is
02 er enabled. This switch is used for the compatibility of the HSPA+
03 Bas terminals that do not support CM when HSPA+ is enabled.
03 ed GUI Value Range: FALSE(Forbidden), TRUE(Permit)
on Unit: None
Cov
Actual Value Range: FALSE, TRUE
erag
e Default Value: FALSE(Forbidden)
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
EHSP B SET W Inte Meaning: Whether the compressed mode (CM) can be activated
ACM S UCM RF r when an HSPA+ service is in progress and whether an HSPA+
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Permi C CF D- Fre service can be set up when the CM is active. If this parameter is
ssionI 6 02 que set to TRUE: 1. the RNC can enable the CM for HSPA+
nd 9 03 ncy services. 2. The HSPA+ services can be enabled when the CM is
1 02 Har enabled. If this parameter is set to FALSE: 1. the CM for HSPA+
0 W d services can be enabled only after the uplink E2D (E-DCH to
RF Han DCH) and downlink H2D (HS-DSCH to DCH) channel switch.
D- dov 2. The HSPA+ services cannot be enabled when the CM is
02 er enabled. This switch is used for the compatibility of the HSPA+
03 Bas terminals that do not support CM when HSPA+ is enabled.
03 ed GUI Value Range: FALSE(Forbidden), TRUE(Permit)
on Unit: None
Cov
Actual Value Range: FALSE, TRUE
erag
e Default Value: FALSE(Forbidden)
Inte
r-
RA
T
Han
dov
er
Bas
ed
on
Cov
erag
e
McHs B SET No Non Meaning: Whether the RNC reconfigures MC-HSDPA services
dpaLt S UCM ne e as HSDPA services for UEs during the LTE cell measurement in
eCMP C CF CM. If this parameter is set to FALSE, The RNC reconfigures
ermiss 6 MC-HSDPA services as HSDPA services. If this parameter is set
ionInd 9 to TRUE, The original algorithm applies.
0 GUI Value Range: FALSE(Forbidden), TRUE(Permit)
0 Unit: None
Actual Value Range: FALSE, TRUE
Default Value: TRUE(Permit)
McHs B SET No Non Meaning: Whether the RNC reconfigures MC-HSDPA services
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
dpaLt S UCM ne e as HSDPA services for UEs during the LTE cell measurement in
eCMP C CF CM. If this parameter is set to FALSE, The RNC reconfigures
ermiss 6 MC-HSDPA services as HSDPA services. If this parameter is set
ionInd 9 to TRUE, The original algorithm applies.
1 GUI Value Range: FALSE(Forbidden), TRUE(Permit)
0 Unit: None
Actual Value Range: FALSE, TRUE
Default Value: TRUE(Permit)
PS_STREAM_IU_QOS_NEG_ENHANCE_SWITCH,
PS_STREAM_IU_QOS_RENEG_SWITCH
Default Value:
PS_BE_EXTRA_LOW_RATE_ACCESS_SWITCH:0,PS_BE_I
NIT_RATE_DYNAMIC_CFG_SWITCH:0,PS_BE_IU_QOS_N
EG_SWITCH:0,PS_RAB_DOWNSIZING_SWITCH:1,PS_STR
EAM_IU_QOS_NEG_SWITCH:0,PS_BE_STRICT_IU_QOS_
NEG_SWITCH:0,HSPA_ADPTIVE_RATE_ALGO_SWITCH:0
,PS_CM_COV_H2D_0K_SWITCH:0,PS_CMACTIVE_PROCE
SS_OPT_SWITCH:0,PS_CMTIMEOUT_UP_LIMIT_SWITCH
:0,PS_STREAM_IU_QOS_NEG_ENHANCE_SWITCH:0,
PS_STREAM_IU_QOS_RENEG_SWITCH:1
services takes effect. When this switch is turned on, the Iu QoS
negotiation Enhancement function of PS streaming services
takes effect. The Iu QoS negotiation enhancement function of PS
streaming services includes the following: 1)The Iu QoS
negotiation on alternative guarantee bit rates of PS streaming
services is now supported. 2)The Iu QoS negotiation function of
PS services is supported in the inter-RAT handover process.
When this switch is turned off, the Iu QoS negotiation
Enhancement function of PS streaming services does not take
effect. 12. PS_STREAM_IU_QOS_RENEG_SWITCH: Whether
Iu QoS re-negotiation is performed for PS streaming services.
When this switch is turned on, Iu QoS re-negotiation is
performed for streaming services. That is, if the rate over the Uu
interface changes after the RAB establishment, the RNC sends
the RAB MOBIFY REQUEST message to instruct the CN to
modify the maximum bit rate and guarantee bit rate. When this
switch is turned off, Iu QoS re-negotiation is not performed for
streaming services.
GUI Value Range:
PS_BE_EXTRA_LOW_RATE_ACCESS_SWITCH,
PS_BE_INIT_RATE_DYNAMIC_CFG_SWITCH,
PS_BE_IU_QOS_NEG_SWITCH,
PS_RAB_DOWNSIZING_SWITCH,
PS_STREAM_IU_QOS_NEG_SWITCH,
PS_BE_STRICT_IU_QOS_NEG_SWITCH,
HSPA_ADPTIVE_RATE_ALGO_SWITCH,
PS_CM_COV_H2D_0K_SWITCH,
PS_CMACTIVE_PROCESS_OPT_SWITCH,
PS_CMTIMEOUT_UP_LIMIT_SWITCH,
PS_STREAM_IU_QOS_NEG_ENHANCE_SWITCH,
PS_STREAM_IU_QOS_RENEG_SWITCH
Unit: None
Actual Value Range:
PS_BE_EXTRA_LOW_RATE_ACCESS_SWITCH,
PS_BE_INIT_RATE_DYNAMIC_CFG_SWITCH,
PS_BE_IU_QOS_NEG_SWITCH,
PS_RAB_DOWNSIZING_SWITCH,
PS_STREAM_IU_QOS_NEG_SWITCH,
PS_BE_STRICT_IU_QOS_NEG_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
HSPA_ADPTIVE_RATE_ALGO_SWITCH,
PS_CM_COV_H2D_0K_SWITCH,
PS_CMACTIVE_PROCESS_OPT_SWITCH,
PS_CMTIMEOUT_UP_LIMIT_SWITCH,
PS_STREAM_IU_QOS_NEG_ENHANCE_SWITCH,
PS_STREAM_IU_QOS_RENEG_SWITCH
Default Value:
PS_BE_EXTRA_LOW_RATE_ACCESS_SWITCH:0,PS_BE_I
NIT_RATE_DYNAMIC_CFG_SWITCH:0,PS_BE_IU_QOS_N
EG_SWITCH:0,PS_RAB_DOWNSIZING_SWITCH:1,PS_STR
EAM_IU_QOS_NEG_SWITCH:0,PS_BE_STRICT_IU_QOS_
NEG_SWITCH:0,HSPA_ADPTIVE_RATE_ALGO_SWITCH:0
,PS_CM_COV_H2D_0K_SWITCH:0,PS_CMACTIVE_PROCE
SS_OPT_SWITCH:0,PS_CMTIMEOUT_UP_LIMIT_SWITCH
:0,PS_STREAM_IU_QOS_NEG_ENHANCE_SWITCH:0,
PS_STREAM_IU_QOS_RENEG_SWITCH:1
FastH B ADD W HS Meaning: Activation time offset delivered to the UE during the
SCCA S UCE RF DP fast HSDPA serving cell change procedure. This parameter is an
ctTim C LLRL D- A advanced parameter. Therefore, modify the setting of this
eDefO 6 ACT 01 Mo parameter under the instruction of Huawei technical support.
ffVal 9 TIME 06 bilit GUI Value Range: 1~255
0 MOD 10 y Unit: 10ms
0 UCE 06 Ma
Actual Value Range: 10~2550
LLRL nag
eme Default Value: 30
ACT
TIME nt
FastH B ADD W HS Meaning: Activation time offset delivered to the UE during the
SCCA S UCE RF DP fast HSDPA serving cell change procedure. This parameter is an
ctTim C LLRL D- A advanced parameter. Therefore, modify the setting of this
eDefO 6 ACT 01 Mo parameter under the instruction of Huawei technical support.
ffVal 9 TIME 06 bilit GUI Value Range: 1~255
1 MOD 10 y Unit: 10ms
0 UCE 06 Ma
Actual Value Range: 10~2550
LLRL nag
eme Default Value: 30
ACT
TIME nt
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
14)FAST_H_SERV_CELL_CHANGE_DISABLED_SWITCH
(Fast HSDPA Serving Cell Change Optimization Disable Switch)
Whether to disable the fast HSDPA serving cell change
optimization function for a specified UE. 1: When this switch is
turned on, the fast HSDPA serving cell change optimization
function cannot be used for a specified UE. The original HSDPA
serving cell change procedure is used. 0: When this switch is
turned off, the fast HSDPA serving cell change optimization
function can be used for a specified UE.
15)SPECUSER_R6_EFACH_CMP_SWITCH Whether the RNC
performs special processing on special users that comply with
3GPP Release 6 when these users mistakenly switch to the
enhanced CELL_FACH state in an E-FACH cell. 1: When this
switch is set to on, special users are not allowed to switch to the
CELL_PCH or CELL_FACH state. That is, when special users
have data to transmit, they switch to the CELL_DCH state.
Otherwise, they stay in the idle mode. When special users move
from a FACH cell to an E-FACH cell and initiate a cell
reselection or cell update procedure, the RNC releases the
special users' connections after the cell update or cell reselection
procedure is complete if the UE is in the CELL_FACH state
before the cell reselection or cell update procedure. If the UE is
in the CELL_PCH state before the cell reselection or cell update
procedure, the RNC switches the UE to the CELL_DCH state. 0:
When this switch is set to off, the RNC performs no special
processing on the UE.
GUI Value Range: P2F_REDIR_DISABLED_SWITCH,
SPECUSER_SRB_OVER_HSDPA_DISABLED_SWITCH,
SPECUSER_CPC_DTX_DRX_DISABLED_SWITCH,
SPECUSER_EFACH_DISABLED_SWITCH,
SPECUSER_ERACH_DISABLED_SWITCH,
SPECUSER_PCH_FACH2EFACH_DISABLED_SWITCH,
SPECUSER_INHIBIT_D2P_SWITCH,
H_SERV_CELL_CHG_MSG_OPT_DISABLED_SWITCH,
EFACH_ERACH_UE_D2P_DISABLED_SWITCH,
SPECUSER_DL_BLER_MEAS_DISABLED_SWITCH,
SPECUSER_AGPS_MEAS_DISABLED_SWITCH,
SPECUSER_UE_TX_PWR_MEAS_DISABLED_SWITCH,
SPECUSER_CELLID_RTT_MEAS_DISABLED_SWITCH,
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
FAST_H_SERV_CELL_CHANGE_DISABLED_SWITCH,
SPECUSER_R6_EFACH_CMP_SWITCH
Unit: None
Actual Value Range: P2F_REDIR_DISABLED_SWITCH,
SPECUSER_SRB_OVER_HSDPA_DISABLED_SWITCH,
SPECUSER_CPC_DTX_DRX_DISABLED_SWITCH,
SPECUSER_EFACH_DISABLED_SWITCH,
SPECUSER_ERACH_DISABLED_SWITCH,
SPECUSER_PCH_FACH2EFACH_DISABLED_SWITCH,
SPECUSER_INHIBIT_D2P_SWITCH,
H_SERV_CELL_CHG_MSG_OPT_DISABLED_SWITCH,
EFACH_ERACH_UE_D2P_DISABLED_SWITCH,
SPECUSER_DL_BLER_MEAS_DISABLED_SWITCH,
SPECUSER_AGPS_MEAS_DISABLED_SWITCH,
SPECUSER_UE_TX_PWR_MEAS_DISABLED_SWITCH,
SPECUSER_CELLID_RTT_MEAS_DISABLED_SWITCH,
FAST_H_SERV_CELL_CHANGE_DISABLED_SWITCH,
SPECUSER_R6_EFACH_CMP_SWITCH
Default Value:
P2F_REDIR_DISABLED_SWITCH:0,SPECUSER_SRB_OVE
R_HSDPA_DISABLED_SWITCH:0,
SPECUSER_CPC_DTX_DRX_DISABLED_SWITCH:0,
SPECUSER_EFACH_DISABLED_SWITCH:0,
SPECUSER_ERACH_DISABLED_SWITCH:0,SPECUSER_P
CH_FACH2EFACH_DISABLED_SWITCH:0,SPECUSER_IN
HIBIT_D2P_SWITCH:0,H_SERV_CELL_CHG_MSG_OPT_D
ISABLED_SWITCH:0,EFACH_ERACH_UE_D2P_DISABLE
D_SWITCH:0,SPECUSER_DL_BLER_MEAS_DISABLED_S
WITCH:0,SPECUSER_AGPS_MEAS_DISABLED_SWITCH:0
,SPECUSER_UE_TX_PWR_MEAS_DISABLED_SWITCH:0,S
PECUSER_CELLID_RTT_MEAS_DISABLED_SWITCH:0,FA
ST_H_SERV_CELL_CHANGE_DISABLED_SWITCH:0,SPE
CUSER_R6_EFACH_CMP_SWITCH:0
SPECUSER_CPC_DTX_DRX_DISABLED_SWITCH,
SPECUSER_EFACH_DISABLED_SWITCH,
SPECUSER_ERACH_DISABLED_SWITCH,
SPECUSER_PCH_FACH2EFACH_DISABLED_SWITCH,
SPECUSER_INHIBIT_D2P_SWITCH,
H_SERV_CELL_CHG_MSG_OPT_DISABLED_SWITCH,
EFACH_ERACH_UE_D2P_DISABLED_SWITCH,
SPECUSER_DL_BLER_MEAS_DISABLED_SWITCH,
SPECUSER_AGPS_MEAS_DISABLED_SWITCH,
SPECUSER_UE_TX_PWR_MEAS_DISABLED_SWITCH,
SPECUSER_CELLID_RTT_MEAS_DISABLED_SWITCH,
FAST_H_SERV_CELL_CHANGE_DISABLED_SWITCH,
SPECUSER_R6_EFACH_CMP_SWITCH
Default Value:
P2F_REDIR_DISABLED_SWITCH:0,SPECUSER_SRB_OVE
R_HSDPA_DISABLED_SWITCH:0,
SPECUSER_CPC_DTX_DRX_DISABLED_SWITCH:0,
SPECUSER_EFACH_DISABLED_SWITCH:0,
SPECUSER_ERACH_DISABLED_SWITCH:0,SPECUSER_P
CH_FACH2EFACH_DISABLED_SWITCH:0,SPECUSER_IN
HIBIT_D2P_SWITCH:0,H_SERV_CELL_CHG_MSG_OPT_D
ISABLED_SWITCH:0,EFACH_ERACH_UE_D2P_DISABLE
D_SWITCH:0,SPECUSER_DL_BLER_MEAS_DISABLED_S
WITCH:0,SPECUSER_AGPS_MEAS_DISABLED_SWITCH:0
,SPECUSER_UE_TX_PWR_MEAS_DISABLED_SWITCH:0,S
PECUSER_CELLID_RTT_MEAS_DISABLED_SWITCH:0,FA
ST_H_SERV_CELL_CHANGE_DISABLED_SWITCH:0,SPE
CUSER_R6_EFACH_CMP_SWITCH:0
UlLdr B ADD W Loa Meaning: Threshold for triggering uplink LDR. If the ratio of the
TrigT S UCE RF d uplink load to the uplink capacity is higher than or equal to this
hd C LLLD D- Me threshold for a duration longer than that specified by the
6 M 02 asur "UlLdTrnsHysTime" parameter, uplink LDR (preliminary
9 MOD 01 eme congestion state) is triggered and LDR actions are performed to
0 UCE 02 nt reduce the cell load. The recommended value difference between
0 LLLD W Inte "UlLdrRelThd" and "UlLdrTrigThd" is higher than 10% because
M RF r the load fluctuates. Otherwise, a cell frequently enters and leaves
D- Fre the preliminary congestion state.
02 que GUI Value Range: 0~100
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
01 ncy Unit: %
03 Loa Actual Value Range: 0~100
W d Default Value: 55
RF Bal
D- anc
02 e
01 Loa
06 d
Res
huff
ling
UlLdr B ADD W Loa Meaning: Threshold for triggering uplink LDR. If the ratio of the
TrigT S UCE RF d uplink load to the uplink capacity is higher than or equal to this
hd C LLLD D- Me threshold for a duration longer than that specified by the
6 M 02 asur "UlLdTrnsHysTime" parameter, uplink LDR (preliminary
9 MOD 01 eme congestion state) is triggered and LDR actions are performed to
1 UCE 02 nt reduce the cell load. The recommended value difference between
0 LLLD W Inte "UlLdrRelThd" and "UlLdrTrigThd" is higher than 10% because
M RF r the load fluctuates. Otherwise, a cell frequently enters and leaves
D- Fre the preliminary congestion state.
02 que GUI Value Range: 0~100
01 ncy Unit: %
03 Loa Actual Value Range: 0~100
W d
Default Value: 55
RF Bal
D- anc
02 e
01 Loa
06 d
Res
huff
ling
DlLdr B ADD W Loa Meaning: Threshold for triggering downlink LDR. If the ratio of
TrigT S UCE RF d the downlink load to the downlink capacity is higher than or
hd C LLLD D- Me equal to this threshold for a duration longer than that specified
6 M 02 asur by the "DlLdTrnsHysTime" parameter, downlink LDR
9 MOD 01 eme (preliminary congestion state) is triggered and LDR actions are
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
on
Qo
S
DlLdr B ADD W Loa Meaning: Threshold for triggering downlink LDR. If the ratio of
TrigT S UCE RF d the downlink load to the downlink capacity is higher than or
hd C LLLD D- Me equal to this threshold for a duration longer than that specified
6 M 02 asur by the "DlLdTrnsHysTime" parameter, downlink LDR
9 MOD 01 eme (preliminary congestion state) is triggered and LDR actions are
1 UCE 02 nt performed to reduce the cell load. The recommended value
0 LLLD W Inte difference between "DlLdrRelThd" and "DlLdrTrigThd" is
M RF r higher than 10% because the load fluctuates. Otherwise, a cell
D- Fre frequently enters and leaves the preliminary congestion state.
02 que GUI Value Range: 0~100
01 ncy Unit: %
03 Loa Actual Value Range: 0~100
W d
Default Value: 70
RF Bal
D- anc
02 e
01 Mul
17 ti-
W Car
RF rier
D- Swi
02 tch
01 off
06 Bas
W ed
RF on
D- Traf
02 fic
01 Loa
22 d
Loa
d
Res
huff
ling
Para N MML Fe Fea Description
meter E Com at ture
ID mand ur Na
e me
ID
Mul
ti-
Car
rier
Swi
tch
off
Bas
ed
on
Qo
S
18 Counters
Table 18-1 Counter description
4 Frequency
Hard
Handover
Based on
DL QoS
D- Handover
02030 Based on
6 Load
DL QoS
D- Coverage
02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
Outgoing 3 Coverage
Handovers WRF Inter-RAT
Between D- Handover
Neighboring 02030 Based on
Cells 5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
Handover D- Coverage
Attempts for 02030 Inter
Cell 4 Frequency
WRF Hard
D- Handover
02010 Based on
6 DL QoS
Load
Reshufflin
g
Inter-RAT 6 Load
Handovers
Initiated by
UTRAN
Based on
Load for Cell
Cell 3 Coverage
(Relocation WRF Inter-RAT
Failure in D- Handover
Target 02030 Based on
CN/RNC or 5 Service
Target WRF Inter-RAT
System) D- Handover
02030 Based on
6 Load
02030 Based on
6 Load
5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
for CS 3 Coverage
Incoming WRF Inter-RAT
Inter-RAT D- Handover
Handover for 02030 Based on
RNC 5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
Cell 3 Coverage
WRF Inter-RAT
D- Handover
02030 Based on
5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
Requests
Initiated by
UE for Cell
Neighboring
Cells
Handovers D- Coverage
Attempts 02030 Inter
Between 4 Frequency
Different Hard
NodeBs of Handover
RNC for Cell Based on
DL QoS
Additions 204 nt
and
Deletions by
Soft
Handover for
Cell
Cell
Handover for
Cell
(TRELOCall
oc expiry)
Cell (Traffic
Load In The
Target Cell
Higher Than
In The
Source Cell)
Handover for
cell (No
resource
available)
Attempts
Based on
EcNo for
Cell
Hard
Handover
Based on
DL QoS
DL QoS
Handover
Status for
Cell
Inter- 2 Handover
Frequency WRF Based on
Hard D- Coverage
Handovers 02030 Inter
Between the 4 Frequency
RNCs for Hard
Cell (Invalid Handover
Configuratio Based on
n) DL QoS
Code Power
for Cell
Based on
RSCP for
Cell
Hard D- Frequency
Handovers 02030 Hard
2 Handover
WRF Based on
D- Coverage
02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
Handover
Based on
DL QoS
Hard
Handover
Based on
DL QoS
Intra-RNC 1 Handover
Inter-NodeB WRF Inter
Inter-Cell D- Frequency
Hard 02030 Hard
Handovers 2 Handover
(Physical WRF Based on
Channel D- Coverage
Failure) 02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
02030 Based on
5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
Handover
Preparations
(Relocation
desirable for
radio
reasons)
Handover
Based on
DL QoS
Frequency 2 Handover
Hard Based on
Handovers Coverage
Based on
RSCP for
Cell
Handovers D- Handover
due to UE 02030 Based on
Reselection 5 Service
Back to a WRF Inter-RAT
UTRAN Cell D- Handover
02030 Based on
6 Load
Number of
Occupied
CEs During
RB
Reconfigurat
ion in a
Cell(2ms to
10ms)
02030 Based on
6 Load
CS WRF Inter-RAT
Handovers D- Handover
Due to 02030 Based on
Abnormal 3 Coverage
Connection WRF Inter-RAT
Release by D- Handover
CN for Cell 02030 Based on
(Unspecified 5 Service
Failure) WRF Inter-RAT
D- Handover
02030 Based on
6 Load
5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
02030 Inter-RAT
3 Handover
Based on
Coverage
6 Load
Reshufflin
g
Failure) Based on
DL QoS
Hard 1 Handover
Handovers WRF Inter
for Cell D- Frequency
02030 Hard
2 Handover
WRF Based on
D- Coverage
02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
(Coverage,
QoS, or
HCS) for
Cell
Cell 3 Coverage
WRF Inter-RAT
D- Handover
02030 Based on
5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
02030 Based on
6 Load
5 Service
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
6 Load
Congestion
for Cell
Channel
Change for
Cell
Initiated by
the RNC
Based on
Service Type
for Cell
Inter- 2 Handover
Frequency WRF Based on
Hard D- Coverage
Handovers 02030 Inter
Between 4 Frequency
RNCs for Hard
Cell Handover
Based on
DL QoS
Attempts for
Cell
Cell
Channel
Change for
Cell
Channel
Change for
Cell
Attempts for
Cell(EDCH
to DCH)
Handovers 4 Frequency
Due to Radio Hard
Link Handover
Establishmen Based on
t Failure for DL QoS
Cell
6 Load
Command D- Handover
Expires in PS 02030 Based on
Outgoing 5 Service
Inter-RAT WRF Inter-RAT
Handover D- Handover
Initiated by 02030 Based on
RNC for Cell 6 Load
n
Unsupported
)
Handover for
Cell
Measurement 4 Frequency
Expiry for Hard
Cell Handover
Based on
DL QoS
Attempts Coverage
Based on
RSCP for
Cell
Cell
Activation D- Coverage
Requests for 02030 Inter
Cell 4 Frequency
Hard
Handover
Based on
DL QoS
Hard
Handover
Based on
DL QoS
without
Channel
Change for
Cell
Reconfigurat
ion)
for Cell
Attempts DL QoS
Based on DL
Transmit
Power for
Cell
DL QoS
Based on
DL QoS
Hard D- Frequency
Handover 02030 Hard
Attempts 2 Handover
WRF Based on
D- Coverage
02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
Handover
Based on
DL QoS
Hard
Handover
Based on
DL QoS
Inter-RNC 1 Handover
Inter-Cell WRF Inter
Hard D- Frequency
Handovers 02030 Hard
(Configuratio 2 Handover
n WRF Based on
Unsupported D- Coverage
) 02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
02030 Inter
4 Frequency
Hard
Handover
Based on
DL QoS
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
02030 Based on
6 Load
6 Load
Inter-RAT 3 Coverage
Handover WRF Inter-RAT
Preparations D- Handover
(Relocation 02030 Based on
Failure in 5 Service
Target WRF Inter-RAT
CN/RNC or D- Handover
Target 02030 Based on
System) 6 Load
Handovers 4 Frequency
for Cell Hard
Handover
Based on
DL QoS
Based on
DL QoS
Triggered by
SRVCC for
VoIP
Services for
Cell
Inter-RAT 3 Coverage
Handovers WRF Inter-RAT
for D- Handover
Cell(Signalli 02030 Based on
ng 5 Service
Connection WRF Inter-RAT
Release D- Handover
Indication) 02030 Based on
6 Load
Handover D- Handover
Command 02030 Based on
for Cell 5 Service
for Cell
WRF Inter-RAT
D- Handover
02030 Based on
6 Load
DL QoS
19 Glossary
For the acronyms, abbreviations, terms, and definitions, see Glossary.
20 Reference Documents
1. 3GPP TS 23.122, "Non Access Stratum functions related to Mobile Station (MS) in idle mode"
2. 3GPP TS 24.008, "Mobile radio interface layer 3 specification; Core Network Protocols - Stage 3"
3. 3GPP TS 25.304, "UE Procedures in Idle Mode and Procedures for Cell Reselection in
Connected Mode"
4. 3GPP TS 25.331, "RRC Protocol Specification"
5. 3GPP TS 23.060, "General Packet Radio Service (GPRS); Service description"
6. 3GPP TS 25.931, "UTRAN Functions, Examples on Signaling Procedures"
7. Directed Retry Decision Feature Parameter Description
8. CE Resource Management Feature Parameter Description
9. Load Control Feature Parameter Description
10. Interoperability Between UMTS and LTE Feature Parameter Description
11. AMR Feature Parameter Description
12. DCCC Feature Parameter Description
13. UE Behaviors in Idle Mode Feature Parameter Description
14. License Management Feature Parameter Description
15. Inter-Frequency Load Balancing Feature Parameter Description