Anda di halaman 1dari 16

PT.

Perusahaan Gas Negara


No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. X65M
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 24 inch = 610 mm
11 OD pl : Outside Diameter of Pipeline = 24 inch = 610 mm
12
13 Pd : Design Pressure = 720 psi = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 65300 psi = 450 M
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.5875 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 8 % = 0.08
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27 2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.4410 in
32 = 11.2025 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 = 0.547 inch = 13.90 mm
37
38 t selected = 0.562 inch = 14.27 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. X42M
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 16 inch = 406 mm
11 OD pl : Outside Diameter of Pipeline = 16 inch = 406 mm
12
13 Pd : Design Pressure = 720 psi = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 42100 psi = 290 MPa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.5875 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 10 % = 0.1
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.4561 in
32 = 11.5838 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 = 0.576 inch = 14.63 mm
37
38 t selected = 0.625 inch = 15.88 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. X52M
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 16 inch = 406 mm
11 OD pl : Outside Diameter of Pipeline = 16 inch = 406 mm
12
13 Pd : Design Pressure = 720 Psi = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 52200 Psi 360 Mpa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.5875 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 10 % = 0.1
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.3678 in
32 = 9.3425 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 = 0.478 inch = 12.14 mm
37
38 t selected = 0.500 inch = 12.70 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. BM
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 16 inch = 406 mm
11 OD pl : Outside Diameter of Pipeline = 16 inch = 406 mm
12
13 Pd : Design Pressure = 720 Psi = 50 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 Psi = 245 Mpa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.6 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 10 % = 0.1
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.5408 in
32 = 13.7375 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 = 0.670 inch = 17.03 mm
37
38 t selected = 0.688 inch = 17.48 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. BM
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 12 inch = 305 mm
11 OD pl : Outside Diameter of Pipeline = 12.75 inch = 324 mm
12
13 Pd : Design Pressure = 720 psi = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.5875 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 10 % = 0.1
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.4310 in
32 = 10.9470 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.548 inch = 13.93 mm
37
38 t selected = 0.562 inch = 14.27 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. X46M
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 12 inch = 305 mm
11 OD pl : Outside Diameter of Pipeline = 12.75 inch = 324 mm
12
13 Pd : Design Pressure = 720 Psi = 50 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 46400 Psi 320 Mpa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.6 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21
22 Parameter of Calculation
23 a. The equation for minimum wall thickness
24
PD
25
t min
26
2 SFET
27
28 b. Design wall thickness
29
30 t min = 0.3297 in
31 8.3754 mm
32
33 CONCLUSION
34 Wall thickness for Line Pipe
35 t design = t min + CA = 0.392 inch = 9.96 mm
36
37 t selected = 0.406 inch = 10.31 mm
38
39
40 where,
41 t min = Minimum design wall thickness due to internal pressure
42 t design = Minimum wall thickness for installation
43 t selected = Selected wall thickness
44
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. X42M
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 12 inch = 305 mm
11 OD pl : Outside Diameter of Pipeline = 12.75 inch = 324 mm
12
13 Pd : Design Pressure = 720 Psi = 50 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 42100 Psi 290 Mpa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.6 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21
22 Parameter of Calculation
23 a. The equation for minimum wall thickness
24
PD
25
t min
26
2 SFET
27
28 b. Design wall thickness
29
30 t min = 0.3634 in
31 9.2309 mm
32
33 CONCLUSION
34 Wall thickness for Line Pipe
35 t design = t min + CA = 0.426 inch = 10.82 mm
36
37 t selected = 0.438 inch = 11.13 mm
38
39
40 where,
41 t min = Minimum design wall thickness due to internal pressure
42 t design = Minimum wall thickness for installation
43 t selected = Selected wall thickness
44
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. BM
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 10 inch = 254 mm
11 OD pl : Outside Diameter of Pipeline = 10.75 inch = 273 mm
12
13 Pd : Design Pressure = 720 psi = 50 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.5875 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 10 % = 0.1
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.3634 in
32 = 9.2299 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.473 inch = 12.02 mm
37
38 t selected = 0.500 inch = 12.70 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : ASTM A106 Gr.B
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 4 inch = 102 mm
11 OD pl : Outside Diameter of Pipeline = 4.5 inch = 114 mm
12
13 Pd : Design Pressure = 720 psi = 50 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.1260 inch = 3.2 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 12.5 % = 0.125
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.1521 in
32 3.8637 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.318 inch = 8.07 mm
37
38 t selected = 0.337 inch = 8.56 mm
39 80
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : ASTM A106 Gr.B
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 4 inch = 102 mm
11 OD pl : Outside Diameter of Pipeline = 4.5 inch = 114 mm
12
13 Pd : Design Pressure = 235 psi = 16.20 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.1250 inch = 3.175 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.0496 in
32 = 1.2611 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.175 inch = 4.44 mm
37
38 t selected = 0.237 inch = 6.02 mm
39 SCH 40
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. X42M
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 2 inch = 51 mm
11 OD pl : Outside Diameter of Pipeline = 2.375 inch = 60 mm
12
13 Pd : Design Pressure = 720 pai = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 42100 psi = 290 MPa
16
17 CA : Corrosion Allowance = 0.1250 inch = 3.175 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 0
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.0677 in
32 = 1.7195 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.193 inch = 4.89 mm
37
38 t selected = 0.218 inch = 5.54 mm
39 SCH 80
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : ASTM A106 Gr.B
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 2 inch = 51 mm
11 OD pl : Outside Diameter of Pipeline = 2.375 inch = 60 mm
12
13 Pd : Design Pressure = 720 pai = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.1250 inch = 3.175 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.0803 in
32 = 2.0392 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.205 inch = 5.21 mm
37
38 t selected = 0.218 inch = 5.54 mm
39 SCH 80
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : ASTM A106 Gr.B
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 2 inch = 51 mm
11 OD pl : Outside Diameter of Pipeline = 2.375 inch = 60 mm
12
13 Pd : Design Pressure = 235 psi = 16 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.1260 inch = 3.2 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 12.5 % = 0.125
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.0262 in
32 0.6656 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.174 inch = 4.42 mm
37
38 t selected = 0.203 inch = 5.16 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : ASTM A106 Gr.B
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 1 inch = 25.4 mm
11 OD pl : Outside Diameter of Pipeline = 1.315 inch = 33.4 mm
12
13 Pd : Design Pressure = 720 psi = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.1250 inch = 3.175 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.0445 in
32 = 1.1290 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.169 inch = 4.30 mm
37
38 t selected = 0.250 inch = 6.35 mm
39 SCH 160
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : ASTM A106 Gr.B
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 0.75 inch = 19 mm
11 OD pl : Outside Diameter of Pipeline = 1.05 inch = 27 mm
12
13 Pd : Design Pressure = 720 psi = 49.64 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.1250 inch = 3.175 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27
2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.0355 in
32 = 0.9015 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.160 inch = 4.08 mm
37
38 t selected = 0.219 inch = 5.56 mm
39 SCH 160
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45
PT. Perusahaan Gas Negara
No (Persero) Tbk.
1 GENERAL
2 Code : ASME B31.8
3 Description : Line Pipe
4 Material : API 5L Gr. BM
5 Condition : Operating
6
7 WALL THICKNESS CALCULATION
8 Input Data
9
10 D pl : Nominal Diameter of Pipeline = 6 inch = 152 mm
11 OD pl : Outside Diameter of Pipeline = 6.625 inch = 168 mm
12
13 Pd : Design Pressure = 720 psi = 50 barg
14 Td : Design Temperature = 130 o
F = 54.44 o
C
15 S : Specified Minimum Yield Stress = 35500 psi = 245 MPa
16
17 CA : Corrosion Allowance = 0.0625 inch = 1.5875 mm
18 E : Joint Efficiency Factor = 1.00
19 F : Design Factor (Class 4) = 0.30
20 T : Temperature Derating Factor = 1.000
21 MT : Mill Tolerance = 10 % = 0.1
22
23 Parameter of Calculation
24 a. The equation for minimum wall thickness
25
PD
26
t min
27 2 SFET
28
29 b. Design wall thickness
30
31 t min = 0.2239 in
32 = 5.6882 mm
33
34 CONCLUSION
35 Wall thickness for Line Pipe
36 t design = t min + CA = 0.318 inch = 8.08 mm
37
38 t selected = 0.432 inch = 10.97 mm
39
40
41 where,
42 t min = Minimum design wall thickness due to internal pressure
43 t design = Minimum wall thickness for installation
44 t selected = Selected wall thickness
45