For FEXX refer below table with the coversion of 1 ksi = 6.89476 Mpa
ASD
Allowable strength = Rn Permissible strength
For 6mm weld For 6mm weld
Effective area = 0.707 x 6 mm x 1mm length Effective area
Aw = 4.242 mm 2
Hence, Hence,
For 6mm weld and A36 steel For 6mm weld and A36 steel
Considering = 90 o Considering
Allowable strength = 0.60*FEXX*(1.0+0.5*Sin1.5) * Aw Design strength
= 921 N for 1mm length of weld
mm weld
= 0.707 x 6 mm x 1mm length
Aw = 4.242 mm 2
h of weld = 1044 mm
ngency factor = 1
= 1
carrying capacity = 961.524 / (1x1)
r capacity) = 961.52 kN for 1044mm length of weld.
Flat bar size
Width B = 30 mm
Depth D = 3 mm B
RoGyr r = 0.87 mm
Length L = 234 mm
Eff. Length factor K = 2 D
Weight of angle
Length 21 Nos * 13.3 m
5 Nos * 20.34 m
Total 381 m
Wt. = 670.0 kg
kg
kg
kg
kg
kN
LOAD TRANSFER BETWEEN ANGLE SUPPORTS OF LINING PANEL AND ANGLE SUPPORT FOR RAISED FLOOR
Total load to be transferred from one angle to the other angle = 0.21 + 2.25 + 0.039
= 2.50 kN