Anda di halaman 1dari 4

NOTES:

1. CUSTOMER TO PROVIDE A "DRY CLEAN AIR SUPPLY" (DCAS) BETWEEN 4.14 AND 17.24 BARG
(60 AND 250 PSIG). DO NOT USE TAPE AS SEALANT ON ANY THREADED CONNECTION OR JOINT.
RECOMMENDED SIZE OF SUPPLY AND SIGNAL AIR TUBING IS 3/8".
2. EACH ALARM AND TRIP TABLE IS ASSOCIATED WITH A SPECIFIC STAGE. OTHER ALARM AND
TRIP SETTINGS CAN BE MADE AT THE CUSTOMER'S DISCRETION.
3. INLET CONTROL VALVE SHOULD BE PRECEDED BY A MINIMUM OF 4 PIPE DIAMETERS
STRAIGHT RUN OF PIPE TO INSURE UNIFORM FLOW DISTRIBUTION AT THE VALVE.
4. LOCATE THE CHECK VALVE IN A HORIZONTAL SECTION OF PIPING.
5. RULES FOR PROPER COMPRESSOR VENTING:
a. ALL VENT PIPING MUST BE AS SHORT AS AND STRAIGHT AS POSSIBLE. RESTRICTIONS
CREATE PRESSURE DROPS THAT IMPEDE VENTING AND CAUSE COMPRESSOR SURGING
b. THE PIPING IMMEDIATELY DOWNSTREAM OF THE BYPASS SILENCER MUST RETURN TO A
LOW PRESSURE POINT. THIS PIPE SIZE MUST BE EQUAL OR GREATER THAN THE PIPE
SIZE AT THE LOW PRESSURE POINT TO ASSURE MINIMAL PRESSURE DROP IN THE PIPE.
c. THE COMPRESSOR DISCHARGE PIPE TO THE BLOW-OFF VALVE SHOULD NOT EXCEED 10
FT.(3.0 M)
d. THE MAXIMUM DISCHARGE VOLUME BETWEEN THE COMPRESSOR DISCHARGE, CHECK
INLET DISCHARGE VALVE, AND BLOW-OFF VALVE IS NOT TO EXCEED 0.1% OF ICFM MAX.
PRESSURE TEMPERATURE PRESSURE TEMPERATURE
STAGE 6. VIBRATION SYSTEM USES A BENTLY NEVADA 3300 NSV (RAM PROBE), EXTENSION CABLE, AND
BARG PSIG BARG PSIG 990 SERIES, 4-20MA, 2 WIRE TRANSMITTER.
1 13.79 200.0 176.7 350.0 29.99 435.0 176.7 350.0
7. CAMERON TO SUPPLY COMPANION FLANGES AT CUSTOMER CONNECTIONS AND FOR LOOSE
2 29.99 435.0 176.7 350.0 41.71 605.0 176.7 350.0 SHIPPED FLANGED DEVICES. FLANGES TO BE WELD-NECK TYPE, CAMERON TO SUPPLY NUTS,
3 41.71 605.0 176.7 350.0 52.40 760.0 176.7 350.0 BOLTS AND SPIRAL WOUND GASKETS WITH THE FLANGES.
8. THE USER IS REQUIRED TO PROVIDE INLET PRESSURE CONTROL TO PREVENT MECHANICAL
OVERLOADING OF THE COMPRESSOR DURING OPERATION. CAMERON COMPRESSION
COOLER DESIGN
PRESSURES/TEMPERATURES
REQUIRES THAT THE INLET PRESSURE TO THE COMPRESSOR NOT EXCEED 110% OF THE
DESIGN INLET PRESSURE.
P T
880 PSIG 9. TO PROPERLY PROTECT THE COMPRESSORS PRESSURE CONTAINING COMPONENTS FROM
A/C OVERPRESSURE DURING SYSTEM OR PROCESS UPSETS- INCLUDING A FAILURE OF THE
60.67 BARG
CONTROL SYSTEM- THE CUSTOMER MUST SUPPLY INLET AND DISCHARGE RELIEF VALVES SET
AT THE FOLLOWING PRESSURES:

FUEL GAS PROCESS FUEL GAS PROCESS


INLET: 197 PSIG (13.58 BARG) DISCHARGE: 758 PSIG (52.26 BARG)

10. DISCHARGE PIPING MUST MEET OR EXCEED PRESSURE/TEMPERATURE RATING FOR 3RD
STAGE PROCESS 1.
11. PDT-XXX FOR 18969 IS PDT-120. PDT-XXX FOR 18970 IS PDT-220.