HP1 HP2
5 meters 5 meters
Outlet Hose
2 wire 300 bar 2 wire 300 bar
Tam single piston hand pumps have been designed Steel Powder Steel Powder
Stand
specifically for use with Tam injection materials. They are Coated Blue Coated Blue
easy to operate, portable and do not require any power.
Their simple design means that they can be easily striped Length 110 cm 110 cm
down and cleaned on site. Tam single piston hand pumps Height 75 cm 75 cm
come in two versions:
Tam HP1: for low volumes (up to 4 litres per minute)
and high pressure (up to 200bar) ► Pump Guidelines
Tam HP2: for high volumes (up to 8 litres per minute)
and low pressure (up to 60bar)
Setting up
Make sure that the pump is on a level, stable working
► Key Benefits surface and that there is clear access around the pump.
www.taminternational.com
Whilst any information and/or specification contained herein is to the best of our knowledge, true and accurate, we always recommend that a trial be carried out to confirm
suitability of the product. Please note regional climatic conditions may cause a variation in the performance of the product. No warranty is given or implied in connection
with any recommendations or suggestions made by us or our representatives, agents or distributors. The information in this data sheet is effective from the date shown
and supersedes all previous data. Please check with your local TAM office to confirm that this is current issue. HP-V1CF-09
Tam HP
Single Piston Pumps
► Equipment Page 2 of 2
Using the Pump Cleaning the pump is extremely important. If it is not done
Specific requirements in the use of the pump depend correctly, it will adversely impact the effectiveness and
largely on the type of material being injected and the working life of the pump. Grit and other solid particles
application. Please consult our Technical support team within the pump will score and wear away at the pump
for more information. parts and eventually stop it from operating.
Extreme care should be taken if using bucket mixed, multi
component materials as they may set before cleaning of
► Trouble shooting
the pump is possible.
Always make sure that the pump is thoroughly cleaned The pump will not suck up the injection material.
after use. Make sure that the intake hose is fully immersed and is
not split.
If the material lifts up the intake hose and then drops
► Ongoing Maintenance
when you lower the handle, remove the bottom seat and
check that the bottom seat is clean and not scratched or
Cleaning the Pump pitted. Also check that the ball bearing is clean and not
Flush as much of the material out of the pump as scratched or pitted. I-if they are, replace them.
possible by removing the intake hose from the material, If both the bottom seat and ball bearing are o.k. there
lift and lower the pump handle as before until satisfied may be particles within the pump. These must be
that all material has been purged from the pump. removed as they will stop the ball from seating correctly.
1. Place the intake hose into a container of TamPur
cleaner with the injection hose valve open and The pump will not hold pressure.
pointing into the cleaner to re-circulate the material. The ‘O’ ring requires replacing. If this does not work, then
2. Lift up and lower the pump handle until the cleaner there is possibly an air leak. Check that all connections
flows through the injection hose. Continue this for are done up securely.
about 1 minute.
3. Close the injection hose valve and continue to lift The pump builds up pressure but material does not
and lower the pump handle until it becomes too stiff come out of the injection hose.
to continue. Gently increase the pressure by pushing There is a blockage. Probably within the injection hose if
down on the handle and hold for a couple of the bleed valve allows material through. If this is the case,
seconds. This will ensure that the cleaner is forced carefully remove the injection hose. f this solves the
into all parts of the pump, in particular the pressure problem, replace the hose without the connector on the
gauge. end of it and try again If it now works, replace the
4. Carefully open the injection hose valve to release connector but if it doesn’t work then the hose will need
the pressure. replacing.
If the problem is not the hose or connector, dismantle the
Repeat steps 3 and 4 several times until satisfied that the bleed valve and thoroughly clean it. If this does not solve
injection material has been purged. Repeat step 1 to the problem then the valve housing will need to be taken
clear the pump of the TamPur cleaner and then using apart and checked for blockages.
fresh cleaner repeat steps 2 to 5 to purge the pump of
contaminated TamPur cleaner as many times as For any other problems, please consult our technical
necessary. support team.
When the pump is not in use for any length of time, Wear protective clothing including full eye and face
(particularly overnight), after cleaning repeat steps 1 to 5 protection. Read and abide by the health and safety data
but this time with engine oil. To ready the pump for use, sheets of all materials used in conjunction with the hand
repeat steps 1 to 5 using TamPur cleaner. pump. Only trained personnel should operate or service
the pump. Cautionary Note: Particles within the pump and
injection lines may stop the pump from functioning, this
may lead to a build up of pressure within the pump.
www.taminternational.com