Anda di halaman 1dari 2

Non-Shrink General Purpose Grout

Commercial grade construction grout


TCC Materials March 2015 Version 1.0

Product Description Technical Data demand and mix temperature must be


SAKRETE Non-Shrink General Purpose determined using standard test methods
Technical Data Tests
Grout is a non-shrink, non-metallic, for consistency and temperature
Portland cement based structural Plastic Flowable measurement at the time of application.
hydraulic cement for high-strength For best results, use a mechanical mixer
Compressive Strength (ASTM C109)
grouting. with rotating blades. Use a mixer large
1 Day 1,940 psi 1,450 psi enough to permit continuous placement
When/Where to Use before any part of the grout has set.
3 Days 3,300 psi 2,790 psi
Grouting of poured in place, precast, Always mix entire contents of bag. Add
7 Days 4,680 psi 4,280 psi approximately of the expected mix
tilt-up and pre-stressed concrete
Grouting of heavy machinery 28 Days 6,770 psi 5,580 psi water into the mixer, add the non-shrink
Grouting of sole plates and steel grout mix, then add additional water in
Height Change Expansion % (ASTM C1090) small increments until desired
bearing plates
1 Day +0.05% +0.03% consistency is reached. Mix no longer
Securing anchor bolts, and dowel rods
than 5 minutes. Do not mix more than
Grouting of post tension steel 3 Days +0.15% +0.13%
can be placed in a 30 minute time frame.
reinforcement in bonded and
14 Days +0.13% +0.11%
unbonded post tensioned concrete Desired Grout Consistency:
applications 28 Days +0.12% +0.10% Flowable (Pumping Consistency), 50
Concrete columns lbs. (22.7kg) grout, approximately 8
Consistency of Flow
pints water (4 L)
Advantages ASTM C942 101% 129%
Plastic (Trowel Consistency), 50 lbs.
Meets ASTM C 1107 Packaged Dry, (22.7 kg) grout, approximately 7 pints
Hydraulic-Cement Grout (Non-shrink) Surface Preparation
water (3.5 L)
Non-chloride formula will not promote Remove all unsound concrete, grease,
corrosion of steel oil, paint, and any other foreign material
Application
Non-shrink, Per ASTM C 1107 that will inhibit performance. Prior to
grout placement, all surfaces must be Read all directions before starting work.
Non-metallic, non-staining, gray color
clean and saturated with water. Remove After cleaning and pre-wetting the
Meets Corps of Engineers
excess water before placing the grout. surface, place the grout quickly in a
Specification CRD-C 621
Provide air relief holes where necessary manner to avoid air entrapment. Rodding
Plastic and flowable fluid consistency
if grouting is beneath large plates. the grout lightly will help move material.
Pumpable for easy placement
Avoid segregation, be careful to not
Super plasticized for improved
Suggestions in Form Work: Wood form overwork grout. Avoid vibration which
strength work or other absorbent forms should be can cause bleeding and segregation.
coated with a form release oil to prevent Shut down nearby machines that will
Packaging
grout adherence and water absorption. cause vibration of the grout for at least
50 lb. (22.7 kg) pail (BOM 120025)
Design form work to facilitate rapid, 24 hours. Whenever possible, bolt holes
continuous and complete filling of the should be grouted first. Placement and
Typical Yield
space to be grouted. Use methods that consolidation should be continuous for
One 50 lb. bag will yield 0.45 cu. ft.
will enable the grout to flow by gravity any one section of the grout. Excess
(12.7 L) at a flowable consistency
between the surfaces and keep the grout grout may be removed after the initial
in full contact with these surfaces until it set. Non-Shrink General Purpose Grout
has hardened. Refer to: ACI 351.R-99 should not be re-tempered. The air, mix,
Report on Grouting between and substrate temperatures should all be
Foundations and Bases for Support between 40F (4.4C) and 90F (32.2C)
WARNING: INJURIOUS TO EYES! Equipment and Machinery for important within 24 hours of application.
information and recommendations
KEEP OUT OF REACH OF CHILDREN!
Curing
Mixing
Non-Shrink General Purpose Grout can
Helpful Items: Add only clean water. The water be exposed under normal weathering
quantities shown are approximate and conditions. Forms may be removed as
may vary slightly with type of equipment soon as the grout reaches its final set.
and application conditions. Water Protect from freezing for a minimum of

2025 Centre Point Blvd, Suite 300 Mendota Heights, MN 55120 | P 651.686.9116 | F 651.688.9164 | www.tccmaterials.com
Non-Shrink General Purpose Grout
Commercial grade construction grout
TCC Materials March 2015 Version 1.0

48 hours after placement. ACI 308- Limited Product Warranty


Standard Practice for Curing Concrete. The manufacturer warrants that this
product shall be of merchantable quality
Clean up when used or applied in accordance with
Use warm, soapy water for cleaning the manufacturers instructions. This
hands and tools while product is wet. product is not warranted as suitable for
SAKRETE Concrete Mortar Dissolver any purpose other than the general
can be used if dried or hardened on tools purpose for which it is intended. This
and equipment. warranty runs for one (1) year from the
dates the product is purchased. ANY
Notes and Limitations IMPLIED WARRANTY OF
Gloves and goggles are MERCHANTABILITY OR FITNESS FOR
recommended safety equipment A PARTICULAR PURPOSE ON THIS
Use only clean mixing container and PRODUCT IS LIMITED TO THE
tools DURATION OF THIS WARRANTY.
Store in tightly closed container off the Liability under this warranty is limited to
floor in a dry place replacement of defective products or, at
Proper application and installation of all the manufacturers option, refund of the
SAKRETE products are the responsibility purchase price. CONSEQUENTIAL AND
of the end user. INCIDENTAL DAMAGES ARE NOT
RECOVERABLE UNDER THIS
Warning WARRANTY.
WARNING! CAUSES IRRITATION -
Avoid contact with eyes, skin and Environmental Advisory
clothing. Wash thoroughly after handling. Uncured or crushed cured cement is an
Exposure may result in irritation of the environmental hazard, which may
skin, eyes or nasal passages from alkali adversely affect fish and wildlife. Dispose
in Portland cement. When wet, contact of construction debris containing cement,
with the skin or eyes may result in including empty bags, at a permitted
irritation or burns. FIRST AID: In case of municipal disposal firm. Do not use
eye contact, flush immediately with crushed concrete as a fill near an aquatic
plenty of water for at least 15 minutes habitat.
and get prompt medical attention; for
skin, wash thoroughly with plenty of soap
and water. If irritation persists, get SAKRETE and the background design are
registered trademarks of SAKRETE of North
medical attention. WARNING! HAMFUL America LLC, Charlotte, NC 28273 2006.
IF INHALED - Avoid breathing dust. SAKRETE is manufactured under license from
Keep container closed. Use with SAKRETE of North America LLC.
adequate ventilation. Excessive
exposure by inhalation over an extended
period of time may result in the
development of pulmonary diseases
including pneumoconiosis and silicosis.
Crystalline Silica has been classified by Shelf Life
One year in original, unopened
container.
IARC and NTP as a carcinogen.
WARNING: Wear protective clothing and Storage Conditions
Store dry in tightly sealed
container.
equipment. KEEP OUT OF REACH OF
CHILDREN. READ and UNDERSTAND the Color Gray
Safety Data Sheet (SDS) before using this
product.

2025 Centre Point Blvd, Suite 300 Mendota Heights, MN 55120 | P 651.686.9116 | F 651.688.9164 | www.tccmaterials.com

Anda mungkin juga menyukai