Anda di halaman 1dari 2

13/04/2017 1/2

UnknownFKB_1B5202,VIN:P762353

ISTA 4.04.12.19097 Data R4.04.12 Programming -


system version data
version
VIN P762353 Vehicle 1'/F20/SHA/M135i/N55/AUTO/ECE/LL/2015/05
Int.lev.works - Int.lev. - Int.lev.(tar.) -
(cur.)
Mileage 0 km

Fault description Diagnosis monitors the voltage supply line of terminals


15N_1 and KL87_1 for open circuit and short to ground.

Malfunction monitoring conditions

The fault is detected when no voltage is applied at the


DME input (KL87_1 or 15N_1) despite the main relay
being enabled.

Condition for fault Voltage precondition


identification
- Vehicle voltage between 9V and 16V

Temperature condition

- None

Time condition

- None

Other preconditions

- None

Terminal status

- Terminal 15

Condition for fault The fault is entered within 10 seconds.


memory entry

Action in service - Check voltage supply

- Wiring harness between DME and main relay


13/04/2017 2/2

- Replace main relay

Fault effect and Breakdown in extreme cases


breakdown warning

Driver information Emissions warning light and engine warning light

Service instruction - None