actual
Data natural gas natural gas+purge gas
desain satuan desain satuan
T 22 C C
P 381 Psi bar
flow kg/hr kg/hr
LHV kcal/kg kcal/kg
LHV kcal/Nm kcal/Nm
GHV 1079.152 Btu/Scf
spesific grafity 0.83 g/cm g/cm
komponen
H - %mol %mol
N 0.063 %mol %mol
CH 89.753 %mol %mol
Ar - %mol %mol
CO 3.529 %mol %mol
CH 2.917 %mol %mol
CH 2.062 %mol %mol
i-CH 0.443 %mol %mol
ni-CH 0.534 %mol %mol
i-CH 0.21 %mol %mol
n-CH 0.137 %mol %mol
CH 0.352 %mol %mol
Nilai Cp
komposisi A B C D E
H2 2.54E+01 2.02E-02 -3.85E-05 3.19E-08 -8.76E-12
N2 2.93E+01 -3.54E-03 1.01E-05 -4.31E-09 2.59E-13
CH4 34.942 -4.00E-02 1.92E-04 -1.53E-07 3.93E-11
AR 20.786 0.00E+00 0.00E+00 0.00E+00 0.00E+00
CO2 27.437 4.23E-02 -1.96E-05 4.00E-09 -2.99E-13
C2H6 28.146 4.34E-02 1.89E-04 -1.91E-07 5.33E-11
C3H8 28.277 1.16E-01 1.96E-04 -2.33E-07 6.87E-11
i-C4 6.772 3.41E-01 -1.03E-04 -3.68E-08 2.04E-11
n-C4 20.056 2.82E-01 -1.31E-04 -9.46E-08 3.41E-11
I-C5 -0.881 4.75E-01 -2.48E-04 6.75E-08 -8.53E-12
n-C5 26.671 3.23E-01 4.28E-04 -1.66E-07 5.60E-11
C6
Actual
Mixed coil preheat Coil
kg-mol/hr kg-mol/hr
flow total kg/hr flow total kg/hr
pressure inlet kg/cma pressure inlet kg/cma
allowable pressure drope k9/cm allowable pressure d k9/cm
T inlet C T inlet C
T outlet C T outlet C
coil duty Mmkcal/hr coil duty Mmkcal/hr
Feed coil superheat coil low presure boiler C
flow total kg-mol/hr flow total steam kg-mol/hr
kg/hr kg/hr
pressure inlet kg/cma pressure inlet kg/cma
allowable pressure drope k9/cm allowable pressure d k9/cm
T inlet C T inlet C
T outlet C T outlet C
coil duty Mmkcal/hr coil duty Mmkcal/hr
COIL
Mixed coil steam and air heater
kg-mol/hr kg-mol/hr
flow total 196928 kg/hr flow total 104204 kg/hr
pressure inlet 39.78 kg/cm pressure inlet 35.15 kg/cm
pressure outlet 39.36 k9/cm pressure outlet 34.16 k9/cm
T inlet 398.1 C T inlet 179 C
T outlet 621.1 C T outlet 441 C
heat absorbtion 15.99 kcal/hr heat absorbtion 10 7.26 kcal/hr
boiler Coil
kg-mol/hr
flow total stea kg/hr
pressure inlet kg/cma
allowable pressure drope k9/cm
T inlet C
T outlet C
coil duty Mmkcal/hr
low presure boiler Coil
water in kg-mol/hr
kg/hr
steam out kg-mol/hr
kg/hr
pressure inlet kg/cma
allowable pressure drope k9/cm
T inlet C
T outlet C
coil duty Mmkcal/hr
actual
Feedpreheat coil
kg-mol/hr
flow total 42156 kg/hr
pressure inlet 41.21 kg/cm
pressure outlet 40.5 k9/cm
T inlet 205 C
T outlet 399 C
heat absorbtion 6.03 kcal/hr