Anda di halaman 1dari 10

Confidential

SII Printek Inc.

Tickling test of RC1536


With ZSCHIMMER&SCHWARZ
Water Based Ink

31th/August/2016
SII Printek Inc.

Revision05
1
Confidential
WaveformBlue-Generation3.0 (ICE897) SII Printek Inc.
Waveform0 (Not fire)

Waveform1 (1drop) 6.4 us

3.4 us

Waveform2 (2drop) 9.4 us 6.4 us

3.0 us 3.2 us

Waveform3 (3drop) 9.8 us 9.6 us 6.4 us

2.6 us 2.8 us 3.0 us

Waveform4 (4drop) 10.2 us 10.0 us 9.8 us 6.4 us

2.6 us 2.8 us 2.8 us 3.0 us

Waveform5 (5drop) 10.2 us 10.0 us 10.0 us 9.8 us 6.4 us

2.6 us 2.8 us 2.8 us 2.8 us 3.0 us

Waveform6 (6drop) 10.2 us 10.0 us 10.0 us 10.0 us 9.8 us 6.4 us

2.8 us 2.8 us 2.8 us 2.8 us 3.0 us 3.0 us

Waveform7 (7drop) 10.0 us 10.0 us 10.0 us 10.0 us 9.8 us 9.8 us 6.4 us

1.4 us

Waveform8 (tickling)

31th/Aug/2016 2
Confidential
WaveformBlue-Generation3.0 (ICE897) SII Printek Inc.

sampleclk=10
waveform0=2@0
waveform1=2@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@1,0@0
waveform2=2@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,94@1,34@0,64@1,0@0
waveform3=2@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,98@1,30@0,96@1,32@0,64@1,0@0
waveform4=2@0,64@0,64@0,64@0,64@0,64@0,64@0,102@1,26@0,100@1,28@0,98@1,30@0,64@1,0@0
waveform5=2@0,64@0,64@0,64@0,64@0,102@1,26@0,100@1,28@0,100@1,28@0,98@1,30@0,64@1,0@0
waveform6=2@0,64@0,64@0,102@1,26@0,100@1,28@0,100@1,28@0,100@1,28@0,98@1,30@0,64@1,0@0
waveform7=2@0,100@1,28@0,100@1,28@0,100@1,28@0,100@1,28@0,98@1,30@0,98@1,30@0,64@1,0@0
waveform8=2@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,64@0,14@1,0@0

Waveform 0 : Not Fire


Waveform 1 : 1drop
Waveform 2 : 2drop
Waveform 3: 3drop
Waveform 4 : 4drop
Waveform 5 : 5drop
Waveform 6 : 6drop
Waveform 7 : 7drop
Waveform 8 : Tickling

31th/Aug/2016 3
Confidential
Test Condition -Tickling test- SII Printek Inc.

Test Print Head : RC1536


Environment : 28 45%
Test Ink : ZSCHIMMER&SCHWARZ Water Based ink
: Generation3.0 Blue ICE897
Ink system : Circulation Ink system for test (made by SPT)
Ink Condition : Degassed
Ink temperature : 45 [degree C] THM1 temperature)
Pressure difference (Pin-Pout) : 9.4 kPa (between inlet port and outlet port)
Average pressure at nozzle : -1.0 kPa
Waveform : 1drop (See Page 2-3, Waveform1)
: Tickling (See Page 2-3, Waveform8)
Frequency : 5kHz
Dpi : 360dpi360dpi
Spitting : None

31th/Aug/2016 4
Confidential
Result -Tickling test- SII Printek Inc.

31th/Aug./2016 Update
Result
Jetting Frequency Tickling Frequency
Tickling time Standing time * Result
(kHz) (kHz)
5.0 2sec < 1min Good
< 1min Good
30min Good
0.50 2sec
3hours Good
5.0 7hours Good
0.25 2sec < 1min NG
2sec < 1min NG
0.17 10sec < 1min Good
10sec 1hour Good
* Left without Tickling and Capping

Recommended Tickling Condition


Tickling Frequency : 0.5 kHz and more
Waveform (Tickling) : 1.4 s
Tickling time : 2 seconds and more

The results with printing image are shown in the Page 6-9.

31th/Aug/2016 5
Confidential
Test Condition -Tickling test- SII Printek Inc.

Tickling Frequency : 0.50 kHz


Tickling time : 2sec
Standing time : 3hour

Printing direction

31th/Aug/2016 6
Confidential
Test Condition -Tickling test- SII Printek Inc.

Tickling Frequency : 0.25 kHz


Tickling time : 2sec
Standing time : < 1min

Printing direction

31th/Aug/2016 7
Confidential
Test Condition -Tickling test- SII Printek Inc.

Tickling Frequency : 0.17 kHz


Tickling time : 2sec
Standing time : < 1min

Printing direction

31th/Aug/2016 8
Confidential
Test Condition -Tickling test- SII Printek Inc.

Tickling Frequency : 0.17 kHz


Tickling time : 10sec
Standing time : 1hour

Printing direction

31th/Aug/2016 9
Confidential
Conclusions SII Printek Inc.

31th/Aug./2016 Update
Recommended Tickling Condition
Tickling Frequency : 0.5 kHz and more
Waveform (Tickling) : 1.4 s
Tickling time : 2 seconds and more

Notes
It is confirmed by the test that the result is no problem under the recommended
condition above, if leaved to stand within 7 hours without Tickling and Capping.
(Not confirmed the printing quality in the case of the standing time that
is more than 7 hours.)
On the other, please be aware that the result will be also depending on the test
condition, too, such as temperature, humidity and so on.
(The details of our test condition is described on Page 4.)
Even during the standing time, it is important to avoid to make ink on surface of nozzle
plate dry. It is recommended to always keep the surface wet as much as possible by
capping the printhead or other alternative ways.
If not gained good printing quality under the recommended condition above on your
test, Additional purging and wiping would work to improve it.