Design Data:
Total Discharge = 18.920 m3/sec
No. of Pumps = 5
Discharge through each pump = 3.7840 m3/sec
Q = AxV
* D2
3.7840 = x 1.30
4
Inlet Bell Diametre ( D ) = 1.93 m
or say = 1.95 m
Motor Floor
+ 428.000
Earth Dan
Trash rack
G.L. + 427.000
SECTION
C.L.of Pump
Trash rack
2.00
3.00
PLAN
Design of Pumps :
1. Design Data:
Total Discharge = 18.9200 Cumecs or 668.10 Cusecs
MDDL = + 413.000 m
FTL of dam = + 426.000 m
Delivery level = + 470.000 m
Pump Platform level = + 428.000 m
Sump floor level = + 409.100 m
Length of delivery pipe = 25.00 m or 82.025 feets
No. of Pumps = 6.0 no's
No. of rows of pressure main = 1.0 no.
Dia. of pressure main = 3.150 m or 10.34 feets
Length of pressure main = 12234.00 m or 40139.75 feets
Hazen William's Co-efficient ( C) = 130.00 (Steel Pipe)
Hazen William's Co-efficient ( C) = 130.00 (HDPE Pipe)
Efficiency of pump = 80.0 %
Pump speed = 740.0 rpm
2.Calculations:
Diacharge through Pressure main = 18.9200 Cumecs or 668.103 Cusecs
Diacharge through each pump = 3.1533 Cumecs or 111.351 Cusecs
or ### ussgpm
= 0.500 x 1.239 ^2
2 x 9.81
= 0.039 m ( or ) 0.128 ft
= 0.200 x 1.239 ^2
2 x 9.81
No's = 1.0
= 0.016 m ( or ) 0.051 ft
iii. Due to 90 deg. bend = 0.900 x V2
2g
= 0.900 x 1.239 ^2
2 x 9.81
= 0.070 m ( or ) 0.231 ft
= 0.230 x 1.239 ^2
2 x 9.81
= 0.018 m ( or ) 0.059 ft
= 108.811 HP
i. Loss in line shaft
Dia. of line shaft = HP x 32100 0.33
7000.0 x Pump speed
= 0.878 feets
= 0.500 x 1.239 ^2
2 x 9.81
= 0.039 m ( or ) 0.128 ft
= 0.110 x 1.239 ^2
2 x 9.81
= 0.009 m ( or ) 0.028 ft
Total loss in column assembly and delivery pipe upto pressure mains
Total loss = a + b = 0.744 m ( or ) 2.442 ft II
iii. Loss due to friction in pressure main
a) Due to friction
1.85
hf = 10.670 x Q xL
D 4.87
C
1.85
= 10.670 x 18.9200 x 12234.00
3.150 ^4.87 130.00
b) Due to bends
Area = 7.793 m2
Velocity (V) = 2.428 m/sec
c) Exit = 1.000 x V2
2g
= 1.000 x 2.428 ^2
2 x 9.81
= 0.300 m ( or ) 0.986 ft
III
Total losses in Pressure main = 14.675 m ( or ) 16.628 ft
= 2544.841
= 179.862
v. Calculation of HP
HP of each Pump = * Q * H * PF
550 *
where
= Unit weight of water in lb/ft3 62.25
Q = Discharge in cusecs
H = Head in feets
PF = Power factor 1.3
= 5353.321 HP
Add 20% towards cushioning = 1070.664 HP