Calmet TE30
Measure of power network parameters
in class 0.05 or 0.1
Voltage ranges 0.05600V and 0.140kV
Current ranges
0.00112(120)(1200)(30/300/3000)A
Testing of electricity meters
and CT/PT Transformers
Recording and analyse of power quality
Vector, oscilloscope, bar and trend charts
of three phase network
Powering from 50450V AC power network
and internal battery with charger
Large 7" color Touchscreen
and Calmet TE30 PC soft
Data readout and meter control
via USB, Ethernet and Bluetooth
Data storage in SD flash memory card up to 32GB
Calibration Certificate
Examples of applications
Electricity meter testing direct connection Electricity meter testing connection with clamps
1 3 4 6 7 9 10 12 1 3 4 6 7 9 10 12
L1 L1
L2 L2
L3 L3
N N
CT Ratio error and phase error testing Electricity meter testing connection with clamps
S1 S2 S1 S2 S1 S2
P1 P2 P1 P2 P1 P2 S1 S2 S1 S2 S1 S2
L1 P1 P2 P1 P2 P1 P2
L2 L1
L3 L2
L3
www.calmet.com.pl Three Phase Network Analyser and Tester of Electricity Meters and Instrument Transformers TE30 Data sheet EN 2016-03 1/4
The Calmet TE30 as a power network analyser
Smart Calibration Devices
range +20+26C, humidity and power supply voltage in range 50450V, frequency in range 4565Hz)
3) Em sensor basic error, Em=1%+0.1%* (Flexible Clamps FCT3000AC), Em=2%+0.2%* (VoltLiteWire 40kV and
AmpLiteWire 2000A)
4) power and energy errors related to apparent power
5) in voltage range 10600V (Direct)
6) in current range 0.0112A (Direct)
7) in current range: 0.1A12A (Clamps CT10AC), 0.1A120A (Clamps CT100AC), 10A1200A (Clamps CT1000AC)
General parameters
Weight and dimensions (width x height x depth) 2kg (with internal battery) and (270x245x90)mm
50450V / 47...63Hz / 15VA or
Power supply
replaceable batteries Ni-MH 5xAA 1.2V / 2600mAh / 2h
Safety: Isolation protection and Measurement Category IEC 61010-1 and 300V CAT III
Degree of protection IP-40 (device) / IP-67 (ET30 transportation case)
Operation / storage temperature -10+50C / -20+60C
Operation / storage relative humidity <90% @ +0...+30C and <75% @ +30...+50C / <95% @ 0...+50C
www.calmet.com.pl Three Phase Network Analyser and Tester of Electricity Meters and Instrument Transformers TE30 Data sheet EN 2016-03 2/4
The Calmet TE30 as a tester of electricity meters and instrument transformers
Smart Calibration Devices
Testing of instrument transformers (LV and MV current CT and potential PT simultaneously in three phases)
directly on site:
functions of calculating
transformer ratio error directly in
[%],
functions of calculating phase
error,
functions of burden
measurements of transformer
(ambient temperature in range +20+26C, humidity and power supply voltage in range 50-450V, frequency in range
4565Hz)
3) Em sensor basic error, Em=1%+0.1%* (Flexible Clamps FCT3000AC), Em=2%+0.2%* (AmpLiteWire 2000A
and VoltLiteWire 40kV)
www.calmet.com.pl Three Phase Network Analyser and Tester of Electricity Meters and Instrument Transformers TE30 Data sheet EN 2016-03 3/4
The Calmet TE30 as a power quality analyser
Smart Calibration Devices
+20+26C, humidity and power supply voltage in range 50-450V, frequency in range 4565Hz
2) of input for 80-140Hz frequency range of harmonics with linear rise to 0.4% of input for 3200Hz
3)
for 80-140Hz frequency range of harmonics with linear rise to 8 for 3200Hz
4) of input for 80-140Hz frequency range of interharmonics with linear rise to 5% of input for 3200Hz
5) the highest non-harmonic amplitude and frequency
Calmet Ltd
Kukulcza 18, 65-472 Zielona Gora, Poland
Phone +48 68 324 04 56 Fax +48 68 324 04 57
E-mail: mail@calmet.com.pl Web access: http://www.calmet.com.pl
www.calmet.com.pl Three Phase Network Analyser and Tester of Electricity Meters and Instrument Transformers TE30 Data sheet EN 2016-03 4/4