Beam L/C Node Fx kN Fy kN Fz kN Mx kNm My kNm

Max Fx 5066 312 DL+LL+OP-WZ 2014 151.281 1.042 0 0 0


Min Fx 5066 307 DL+WZ 65 -122.859 -0.625 0 0 0
Max Fy 5054 403 DL+EQZ 2008 -76.142 1.245 0 0 0
Min Fy 5054 403 DL+EQZ 34 -77.354 -1.245 0 0 0
Max Fz 5054 301 DL+WX 2008 5.975 1.042 1.136 0 0
Min Fz 5054 301 DL+WX 34 4.267 -1.042 -1.136 0 0
Max Mx 5012 101 DL 2000 10.296 0.982 0 0 0
Min Mx 5012 101 DL 2000 10.296 0.982 0 0 0
Max My 5012 101 DL 2000 10.296 0.982 0 0 0
Min My 5012 101 DL 2000 10.296 0.982 0 0 0
Max Mz 5012 101 DL 2000 10.296 0.982 0 0 0
Min Mz 5012 101 DL 2000 10.296 0.982 0 0 0

Beam L/C Node Fx kN Fy kN Fz kN Mx kNm My kNm


Max Fx 5042 414 DL+LL+OP-EQX 2008 219.005 0.764 0 0 0
Min Fx 5049 406 DL-EQX 2199 -104.04 0.783 0 0 0
Max Fy 10647 401 DL+EQX 2002 -70.829 1.176 0 0 0
Min Fy 10647 401 DL+EQX 46 -72.074 -1.176 0 0 0
Max Fz 10647 303 DL+WZ 46 12.216 -0.973 2.652 0 0
Min Fz 10647 303 DL+WZ 2002 13.924 0.973 -2.652 0 0
Max Mx 5000 101 DL 2000 43.512 0.967 0 0 0
Min Mx 5000 101 DL 2000 43.512 0.967 0 0 0
Max My 5000 101 DL 2000 43.512 0.967 0 0 0
Min My 5000 101 DL 2000 43.512 0.967 0 0 0
Max Mz 5000 101 DL 2000 43.512 0.967 0 0 0
Min Mz 5000 101 DL 2000 43.512 0.967 0 0 0

Maximum Axial Force 219.005 kN


Mz kNm
0
0
0
0
0
0
0
0
0
0
0
0

Mz kNm
0
0
0
0
0
0
0
0
0
0
0
0
OPERATING
LIFT
SEA
ROAD
AISC-ASD - GUSSET CONNECTION

LOADS
Brace Axial Force 219.005 kN
22324.67 kg
INPUT GEOMETRY
Bolt Hole dia 26 mm
Bolt Dia 24 mm
Area of bolt 352.68 mm2
Constant K 0.5
Thickness of gusset 9 mm
Length at Whitmore section L1 200 mm
Width of Plate 200 mm
Width of Whitmore Section Lw 213.86 mm
c/c bolt distance - horizontal 110 mm
c/c bolt distance - vertical 90 mm
Hori edge dist of Tongue plate Leh 45 mm
Vert edge dist of Tongue plate Lev 45 mm
Yield Stress of Tongue Plate Fy 325 MPa
Ultimate Strength Fu 470 MPa
Young's Modulus E 200000 MPa
Strength Ratio
1) Tensile Yielding at Whitmore Section (Eq J4-1)
Partial Safety Factor 1.67
Tensile Strength of gusset Rn/ 374575.1 N 0.585
where Rn=FyxAg
As Tensile Strength is greater than required strength, Hence OK

2)Buckling Strength of Gusset (J4.4/E3)


Partial Safety Factor c 1.67
Area of Gusset Plate Aw/Ag 1924.74 mm2
slenderness ratio Kl1/r 38.49002
As KL/r is greater than 25, use AISC Sec E3

WHEN KL/r > 25 using Sec E3


Fe = 2 x E / (KL/r)2 1331.046 MPa
Fcr 293.4268 MPa
where Fcr = (0.658 ^(Fy/Fe)) x Fy when Fe>0.44Fy or Fcr = 0.877xFe when Fe<0.44Fy
Pn/ = Fcr x Ag/ Pn/ 338185.8 N
Strength Ratio 0.648
As Buckling Strength is greater than the required Strength, Hence OK

WHEN KL/r < 25 using Sec J4.4


Pn/ = Fy x Ag/ Pn/ N/A N
Strength Ratio N/A
N/A
SUMMARY OF RESULTS
Check Strength Ratio
1) Tensile Yielding at Whitmore Section (Eq J4-1) 0.585
2)Buckling Strength of Gusset (J4.4/E3) 0.648

L1=200

Lw=213.86