Anda di halaman 1dari 13

TUGAS PRAKTIKUM

PERANCANGAN PROSES ENERGI


SIMULASI DAN ANALISIS HEAT EXCHANGER
DENGAN SOFTWARE HYSYS

Oleh:
MOHAMMAD ANSHAR JULIASNYAH ALAM
(141734018)
Kelas : 4D-TKE

D4 TEKNIK KONSERVASI ENERGI


JURUSAN TEKNIK KONVERSI ENERGI
POLITEKNIK NEGERI BANDUNG
2017
SOAL
(Sumber: LKPUNTIRTA, 2014)
Alat perpindahan panas shell tube dipergunakan untuk mendinginkan benzena dari
temperature 180F ke temperatur 100F pada laju alir 100 lb/hr dan tekanan 1.2 bar. Air
dipergunakan sebagai cooling yang dialirkan berlawanan arah dengan temperatur masuk 70F
dengan tekanan 1 bar dan laju alir 125 lb/hr. Berapa temperatur keluar air dan bagaimana
kondisi operasi HE double pipe tersebut?
Aliran panas (tube)
Fluida = Benzene
Temperatur (F) = 180
Pressure (bar) = 1.2
Mass Flow (lb/hr) = 100
Pressure drop (kg/cm2) = 0.2
Fouling Resistance (hr.m2.C/kcal) = 0.0002
Diameter Tube, OD (mm) = 19.05
Inside Diameter (mm) = 14
Tube Length (m) = 20
Aliran dingin (shell)
Fluida = Air
Temperatur (F) = 70
Pressure (kg/cm2) =1
Mass Flow (lb/hr) = 125
Pressure drop (kg/cm2) = 0.86
Fouling Resistance (hr.m2.C/kcal) = 0.0004
Diameter shell (mm) = 1500
Jumlah tube/shell = 150
Tube pitch (in) = 1.5

SKEMA

LANGKAH PENYELESAIAN
1. Buka program Aspen HYSYS
2. Pilih new case
3. Kemudian di tab properties pilih component lists, dan masukan komponen yang diketahui
dengan cara meng-klik add

4. Setelah semua komponen dimasukkan, kemudian klik fluid package, lalu pilih Peng-
Robinson

5. Kemudian lakukan simulasi dengan meng-klik tab simulation


6. Setelah itu definisikan aliran umpan yang terlibat dengan memasukan parameter-
parameter yang diketahui di bagian conditions dan composition
7. Kemudian pilih alat heat exchanger, definisikan aliran yang terlibat, parameter- parameter
serta dimensi yang diketahui di bagian design-connections, design-parameters, dan rating-
sizing
8. Setelah semua parameter dimasukkan, kemudian performance heat exchanger bisa
diketahui dari tab performance-details

9. Kemudian untuk hasil akhir simulasi heat exchanger dapat dillihat dari tab worksheet-
conditions
10. Untuk grafik performance heat exchanger, bisa diketahui dari tab performance-plots

JAWABAN
Dari simulasi yang telah dilakukan, maka bisa diketahui bahwa temperatur keluar air dari heat
exchanger sebesar 34.96C.
ANALISA PENGARUH PERUBAHAN INPUT TERHADAP LAJU KELUAR
AIR DAN OVERALL UA

Berdasarkan hasil simulasi yang telah dilakukan sebelumnya, dilakukan perubahan


input pada HE untuk mengetahui pengaruhnya terhadap nilai lainnya. Pada simulasi ini
parameter yang diubah adalah:
1. Temperature masuk Benzene
2. Temperature keluar benzene
3. Tekanan benzene input
4. Mass flow benzene
Setelah dilakukan simulasi dengan mengubah parameter-parameter yang ada
didapatkan tabel sebagai berikut :
Temperature Masuk Benzene
Kondisi awal Kondisi 2 Kondisi 3
Object Variable Value Units Object Variable Value Units Object Variable Value Units
Benzene Temperature 82,2222 C Benzene Temperature 50 C Benzene Temperature 30 C
Benzene Pressure 120 kPa Benzene Pressure 120 kPa Benzene Pressure 120 kPa
Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C
Benzene Out Pressure 100,387 kPa Benzene Out Pressure 100,387 kPa Benzene Out Pressure 100,387 kPa
H20 Temperature 21,1111 C H20 Temperature 21,1111 C H20 Temperature 21,1111 C
H20 Pressure 100 kPa H20 Pressure 100 kPa H20 Pressure 100 kPa
H2O Out Temperature 34,9602 C H2O Out Temperature 24,7654 C H2O Out Temperature 18,8799 C
H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa
E-100 Overall UA 115,262 kJ/C-h E-100 Overall UA 43,0957 kJ/C-h E-100 Overall UA -40,0872 kJ/C-h
2 2
E-100 Overall U 0,641976 kJ/h-m -C E-100 Overall U 0,240031 kJ/h-m -C E-100 Overall U -0,223275 kJ/h-m2-C

Temperature Out Benzene


Kondisi Awal Kondisi 1 Kondisi 2
Object Variable Value Units Object Variable Value Units Object Variable Value Units
Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C
Benzene Pressure 140 kPa Benzene Pressure 120 kPa Benzene Pressure 120 kPa
Benzene Out Temperature 37,7778 C Benzene Out Temperature 60 C Benzene Out Temperature 25 C
Benzene Out Pressure 120,387 kPa Benzene Out Pressure 100,387 kPa Benzene Out Pressure 100,387 kPa
H20 Temperature 21,1111 C H20 Temperature 21,1111 C H20 Temperature 21,1111 C
H20 Pressure 100 kPa H20 Pressure 100 kPa H20 Pressure 100 kPa
H2O Out Temperature 34,9597 C H2O Out Temperature 28,2545 C H2O Out Temperature 38,6281 C
H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa
E-100 Overall UA 115,257 kJ/C-h E-100 Overall UA 37,8879 kJ/C-h E-100 Overall UA 259,987 kJ/C-h
2 2
E-100 Overall U 0,641948 kJ/h-m -C E-100 Overall U 0,211025 kJ/h-m -C E-100 Overall U 1,44806 kJ/h-m2-C
Tekanan Masuk Benzene

Kondisi awal Kondisi 1 Kondisi 2 Kondisi 3

Object Variable Value Units Object Variable Value Units Object Variable Value Units Object Variable Value Units

Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C

Benzene Pressure 120 kPa Benzene Pressure 100 kPa Benzene Pressure 140 kPa Benzene Pressure 80 kPa

Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C

Benzene Out Pressure 100,387 kPa Benzene Out Pressure 80,3867 kPa Benzene Out Pressure 120,387 kPa Benzene Out Pressure 60,3867 kPa

H20 Temperature 21,1111 C H20 Temperature 21,1111 C H20 Temperature 21,1111 C H20 Temperature 21,1111 C

H20 Pressure 100 kPa H20 Pressure 100 kPa H20 Pressure 100 kPa H20 Pressure 100 kPa

H2O Out Temperature 34,9602 C H2O Out Temperature 55,0219 C H2O Out Temperature 34,9597 C H2O Out Temperature 55,0196 C

H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa

E-100 Overall UA 115,262 kJ/C-h E-100 Overall UA 978,937 kJ/C-h E-100 Overall UA 115,257 kJ/C-h E-100 Overall UA 980,139 kJ/C-h

E-100 Overall U 0,641976 kJ/h-m2-C E-100 Overall U 5,45241 kJ/h-m2-C E-100 Overall U 0,641948 kJ/h-m2-C E-100 Overall U 5,45911 kJ/h-m2-C

Massflow masuk Benzene

Kondisi Awal Kondisi 1 Kondisi 2 Kondisi 3

Object Variable Value Units Object Variable Value Units Object Variable Value Units Object Variable Value Units

Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C Benzene Temperature 82,2222 C

Benzene Pressure 120 kPa Benzene Pressure 120 kPa Benzene Pressure 120 kPa Benzene Pressure 120 kPa

Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C Benzene Out Temperature 37,7778 C

Benzene Out Pressure 100,387 kPa Benzene Out Pressure 100,387 kPa Benzene Out Pressure 100,387 kPa Benzene Out Pressure 100,387 kPa

H20 Temperature 21,1111 C H20 Temperature 21,1111 C H20 Temperature 21,1111 C H20 Temperature 21,1111 C

H20 Pressure 100 kPa H20 Pressure 100 kPa H20 Pressure 100 kPa H20 Pressure 100 kPa

H2O Out Temperature 34,9602 C H2O Out Temperature 36,3752 C H2O Out Temperature 39,4241 C H2O Out Temperature 30,2759 C

H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa H2O Out Pressure 15,6628 kPa

E-100 Overall UA 115,262 kJ/C-h E-100 Overall UA 129,33 kJ/C-h E-100 Overall UA 161,521 kJ/C-h E-100 Overall UA 72,1015 kJ/C-h

E-100 Overall U 0,641976 kJ/h-m2-C E-100 Overall U 0,720334 kJ/h-m2-C E-100 Overall U 0,899628 kJ/h-m2-C E-100 Overall U 0,401585 kJ/h-m2-C

Benzene Mass Flow 45,3597 kg/h Benzene Mass Flow 50 kg/h Benzene Mass Flow 60 kg/h Benzene Mass Flow 30 kg/h

Benzene Out Mass Flow 45,3597 kg/h Benzene Out Mass Flow 50 kg/h Benzene Out Mass Flow 60 kg/h Benzene Out Mass Flow 30 kg/h
Berdasarkan data-data diatas didapatkan grafik pengaruh input terhadap laju alir keluaran air dan
overall UA sebagai berikut:

Pengaruh Temperature Masuk Benzene Terhadap


Temperature keluar Air dan overall UA
40 140
35 120

overall UA (kJ/C-h)
100
30
80
Suhu (oC)

25 60
20 40
15 20
0
10
-20
5 -40
0 -60
30 50 82.22
Temp Out Air 18.8799 24.7654 34.9602
Overall UA -40.0872 43.0957 115.262
Suhu (oC)

Temp Out Air Overall UA

Pengaruh Temperature Keluar Benzene Terhadap


Temperature keluar Air dan overall UA
45 300
40

overall UA (kJ/C-h)
250
35
30 200
Suhu (oC)

25
150
20
15 100
10
50
5
0 0
25 37.7778 60
Temp Out Air 38.6281 34.9597 28.2545
Overall UA 259.987 115.257 37.8879
Suhu (oC)

Temp Out Air Overall UA


Pengaruh Tekanan Input Benzene Terhadap
Temperature keluar Air dan overall UA

60 1200

overall UA (kJ/C-h)
50 1000
40 800
Suhu (OC)

30 600
20 400
10 200
0 0
80 100 120 140
Temp Out Air 55.0196 55.0219 34.9602 34.9597
Overall UA 980.139 978.937 115.262 115.257
Axis Title

Temp Out Air Overall UA

Pengaruh Mass flow Benzene Terhadap


Temperature keluar Air dan overall UA
45 180
40 160

overall UA (kJ/C-h)
35 140
30 120
Suhu (OC)

25 100
20 80
15 60
10 40
5 20
0 0
30 45.3597 50 60
Temp Out Benzene 30.2759 34.9602 36.3752 39.4241
Overall UA 72.1015 115.262 129.33 161.521
Mass flow (kg/h)

Temp Out Benzene Overall UA


Berdsarkan hasil simulasi dan analisis didapatkan kesimpulan bahwa:

1. Dengan bertambahnya nilai temperature masuk benzene menyebabkan nilai temperature


keluaran air dan nilai overall UA bertambah.
2. Dengan bertambahnya nilai temperature keluar benzene menyebabkan nilai temperature
keluaran air dan nilai overall UA berkurang.
3. Dengan bertambahnya nilai tekanan masuk benzene menyebabkan nilai temperature
keluaran air dan nilai overall UA berkurang.
4. Dengan bertambahnya nilai mass flow masuk benzene menyebabkan nilai temperature
keluaran air dan nilai overall UA bertambah.

Anda mungkin juga menyukai