Anda di halaman 1dari 6

Thermal Power Plant Calcul

Subject : Coal Parameter

Perihal Satuan

Fixed carbon % %
Volatile matter % %
Moisture % %
Ash % %
Grindability index HGI
Coal calorific value Kcal/kg
Size of the coal to mill mm
Total contract fuel fired Ton/jam

Dikutip dari buku "PRACTICAL B


batu bara dari stockpile akan dige
Pacitan Steam Plant Boiler Specification menggunakan konveyor. Di bawa

Name Symbol

As received Carbon Car


As received Hydrogen Har
As received Oxygen Oar
As received Nitrogen Nar
As received Sulfur St.ar
As received Ash Content Aar
As received Moisture Content M t.ar
Air dried Moisture M ad
Dry ash free Volatile Content Vdaf
As received Lower Heating Value Qner.ar
Grind ability coefficient HGI
hermal Power Plant Calculation PLTU Pacitan 2 x 315 MW

Supplier : PT Bukit Asam (BA 4

Batas Nilai Toleransi


Desain Toleransi (%) Aktual Selisih
Keatas Kebawah
47.56 16% 76 55 29 -18.56
50 0% 50 0 35 15
30 17% 35 0 30 0
3.5 47% 6 3 6 -2.5
45 44% 65 35 52 -7
4120 9% 4500 3900 4500 -380
25 20% 25 20 20 5
53 4% 55 5 51.3 1.7

Dikutip dari buku "PRACTICAL BOILER OPERATION ENGINEERING AND POWER PLANT" hlm. 88, pada umumnya
batu bara dari stockpile akan digerus hingga sebesar 20 - 25 mm, kemudian akan disalurkan ke bunker dengan
menggunakan konveyor. Di bawah bunker terdapat feeder untuk menyalurkan batu bara ke coal mill.

Design coal Coal rank


Unit
rank scope Untuk batas nilai toleransi atas
47.65 55~76 maupun bawah menggunakan
langsung spesifikasi boiler PLTU
3.36 4.5~7 Pacitan
14.49 10~25
0.77 0.5~1.5
0.23 0.1~0.35 Semua data diambil dari referensi,
3.5 3~6 1) Boiler Operation Manual Pacitan 2 x 315
30 25~35 2) Practical Boiler Operation Engineering an
20 15~25 3) PT Adaro Energy, Tbk Company Profile
50
kcal/kg 4120 3900~4500 Keterangan:
/ 45 45~65 Parameter Terpenting dalam
ier : PT Bukit Asam (BA 45)

Kondisi
Rekomendasi: Salah satu supplier batubara
WARNING emisi yang akan untuk PLTU Pacitan adalah PT
GOOD dihasilkan akan Bukit Asam Tbk, dengan
melewati ambang spesifikasi batu bara jenis BA 45
GOOD batas spesifikasi, ganti (Nilai Kalori 4500 Kcal/Kg)
GOOD dengan mutu batu
bara yang lebih baik.
GOOD
GOOD Untuk mengimbangi,
GOOD dapat menggunakan
batubara Envirocoal
GOOD (Nilai Kalori berkisar
antara 4000 hingga
m. 88, pada umumnya 5000 Kcal/Kg) dari PT
ker dengan Adaro energy, Tbk.
l.
Produk Envircoal
diklaim lebih ramah
lingkungan dengan
kadar volatile dan abu
lebih rendah

mbil dari referensi,


on Manual Pacitan 2 x 315 MW Coal-fired Power Plant (DongFang Electric)
r Operation Engineering and Power Plant (Edisi ke-4)
rgy, Tbk Company Profile

arameter Terpenting dalam menentukan kualitas Batubara


Thermal Power Plant Calculation PL
Subject : Air Preheater

Perihal Satuan Desain

Air quantity at APH outlet (primary) Ton/jam 793


Ambient air oC 50
Air heater outlet (secondary) Ton/jam 533
Total combustion air Ton/jam
Air temperature at fan outlet oC 27.15
Air outlet temperature of APH primary oC 319.66
Air outlet temperature of APH secondary oC 308.67
Oxygen content in flue gas before APH % % 7.42
Excess air % in flue gas before APH % % 53.57
Exhaust gas inlet temperature oC oC 343
Exhaust gas outlet temperature oC oC 134
Exhaust gas quantity tph Ton/jam 768.3
r Plant Calculation PLTU Palabuhan Ratu

Batas Nilai Toleransi


Toleransi (%) Aktual Selisih Kondisi
Keatas Kebawah
Rekomendas
5% 832.65 753.35 714 -79 WARNING Membersihkan
5% 52.5 47.5 36 14 WARNING udara yang da
5% 559.65 506.35 510 23 GOOD
0 0 0 UNKNOWN Rekomendas
5% 28.51 25.73 31.1 -3.95 WARNING Tidak terlalu b
5% 335.643 303.677 331.3 -11.64 GOOD berbagai temp
diterima menc
5% 324.1035 293.2365 323.1 -14.43 GOOD
5% 7.791 7.049 6.52 0.9 WARNING Rekomendas
5% 56.2485 50.8915 44.2 9.37 WARNING Periksa putaran
5% 360.15 325.85 347 -4 GOOD
5% 140.7 127.3 144.8 -10.8 WARNING Rekomendas
5% 806.715 729.885 804.3 -36 GOOD Mengatur ulan

Rekomendas
Mengatur ulan
Keterangan :
Data tidak ditemukan Rekomendas
Periksa profile
pengotor (slag
mengurangi da
Rekomendasi:
Membersihkan filter udara untuk menormalkan kembali kuantitas
udara yang dapat masuk

Rekomendasi:
Tidak terlalu berpengaruh, karena design dapat digunakan di
berbagai tempat hingga suhu lingkungan maksimum yang dapat
diterima mencapai 50 C.

Rekomendasi:
Periksa putaran motor fan dan bersihkan filter

Rekomendasi:
Mengatur ulang perbandingan komposisi pembakaran

Rekomendasi:
Mengatur ulang perbandingan komposisi pembakaran

Rekomendasi:
Periksa profile heat exchanger, apakah terdapat banyak zat
pengotor (slagging, fouling, corrossion) sehingga dapat
mengurangi daya tangkap panas.