Anda di halaman 1dari 2

Highlights of switch disconnectors

Avoid electrical accidents End-to-end safety


Enhanced touch protection thanks to terminal
covers
Locking functions help to prevent unauthorized
operation

Ensure system availability


Enhanced protection against interphase arcing
High reliability thanks to rugged technology

Increase productivity
Modular system ensures fast installation and
easy retrofitting of additional functions
Operating systems safely and reliably
Integrated technology for industrial plants,
infrastructure, and buildings With technical systems, safety is top priority for
personnel and machines. For that reason, it must
Improve flexibility be possible to reliably disconnect the system
Can be used individually as main control, from the power supply when maintenance work
EMERGENCY-STOP, or maintenance switches is performed. At the same time, only an uninter-
Versatile connection options, operating mecha- ruptible power supply can achieve high system
nism designs, and comprehensive accessories availability.
available Switch disconnectors greater safety for
operating personnel
The switch disconnectors from Siemens make it
possible to continuously connect and disconnect
the system under load and protect users from
electric shock. At the same time, they prevent
unauthorized operation on machines.
Transfer switching equipment for a
continuous supply of power
Published by
A power failure can have serious consequences.
The transfer switching equipment from Siemens
Switch disconnectors
Siemens AG 2017
Energy Management achieves reliable and uninterrupted switching

and transfer switching


Siemensstr. 10 between two power sources. In addition, this
93055 Regensburg
same equipment comprises two switch disconnec-
Germany
Article No. EMLP-B10082-00-7600
Dispo 25600 0417 3.0
equipment tors that are connected to each other by means
of a mechanical and an electrical interlock. It
Printed in Germany provides maximum protection and complies with
End-to-end safety for users and systems
Subject to changes and errors the requirements of IEC standards.
The information given in this document only contains general descrip-
tions and/or performance features which may not always specifically
3KF switch disconnectors with fuses are modular and flexible: simple
reflect those described. The requested performance features are binding siemens.com/switching-devices
retrofitting of additional poles
only when they are expressly agreed upon in the concluded contract.
3KC transfer switching equipment 3KD switch disconnectors 3KF switch disconnectors with fuses One click for all information

The new portfolio for your global challenges:


Versions Rated current In: 16 A to 1,600 A Rated current In: 32 A to 800 A
Discover the switch disconnectors and transfer
Remote transfer switching equipment Frame sizes: 5 Frame sizes: 5 switching equipment from Siemens for the reliable
(3KC RTSE) protection of personnel and high system
Number of poles: 3-pole, 4-pole, 6-pole Number of poles: 3-pole, 4-pole availability.
Automatic transfer switching equipment
(3KC ATSE) Connection options: Connection options:
All information at:
Manual transfer switching equipment Box terminal Box terminal
siemens.com/switching-devices
(3KC MTSE) Flat terminal Flat terminal
Rear flat terminal
3KC MTSE Installation:
Standard mounting rail Installation:
Rated current In: 16 A to 1,600 A
Mounting plate Standard mounting rail
Frame sizes: 5
Switching versions: Mounting plate
Number of poles: 3-pole, 4-pole
Direct operating mechanism Switching versions:
Connection options: Door-coupling rotary operating mechanism Direct operating mechanism
Box terminal Side operating mechanism Door-coupling rotary operating mechanism
Flat terminal Side operating mechanism
More information at:
Installation: siemens.com/product?3kd Double contact interruption
Standard mounting rail
Suitable LV HRC fuse links up to 800 A
Mounting plate
More information at:
More information at: siemens.com/product?3kf
siemens.com/product?3kc

Any questions?
Our support staff is always happy to help.

Information Planning/ Operation/ Training


ordering service

We support you from the planning stages to


commissioning to operation.
Technical assistance: +49-911-895-5900
3KC MTSE with direct operating mechanism, 3-pole 3KD switch disconnector with direct operating mechanism, 3-pole 3KF switch disconnector with fuses and direct operating mechanism, siemens.com/lowvoltage/support
3-pole

Anda mungkin juga menyukai