Anda di halaman 1dari 1

1 2 3 4 5 6 7 8 9 10

DO NOT SCALE THIRD ANGLE PROJECTION FIXING SCREW


DIMENSIONS IN MILLIMETRES
TORQUE SETTINGS
M4 2.2 Nm
A A
M5 4.3 Nm
29
M6 7.3 Nm
M8 17.7 Nm

5 M10 35.5 Nm

B 4 B

168

142
1

155

118
131
2

107
84

61

24
37
3 C
C

13
48
67
96

D D

E E

SCHEMATIC

F F
MAINSTAGE PORTS MAINSTAGE VALVE
- 04 (1/4" NPT) - 10 BAR MAX MAINSTAGE PRESSURE
- 06 (3/8" NPT) - 3 BAR MIN PILOT NC, 5 BAR MIN PILOT NO (3 BAR NO - P16 OPTION)
- 08 (1/2" NPT) - NPT PORTS STANDARD (BSP PORTS - K6 OPTION)
- 12 (3/4" NPT) - 1/4" NPT PILOT CONNECTION STANDARD (WHERE APPLICABLE)
- 16 (1" NPT) - 2 OFF M5x9 MOUNTING HOLES
NOTES : We take care to ensure that the product information in this configurator is Bifold Fluidpower Limited
Bifold Group, Oldham Broadway Business Park, Chadderton, Gr. Manchester OL9 9XA
1.) O-RING MATERIAL CODE `X` S = NITRILE reasonably accurate and up-to-date. However, our products are continually Telephone (44) 0161 345 4777 Fax (44) 0161 345 4780

developed and updated so to ensure accurate and up-to-date information PROJECT TITLE PROJECT No.
V = VITON please contact a member of our sales team. SPR-08-06-P1-52-XX-P1-X
G AL = FLUOROSILICONE DRAWING TITLE DRAWING No. REV.
G
When selecting a product, the applicable operating system design must be
AG = SILICONE
considered to ensure safe use. The products function, material compatibility, GENERAL INSTALLATION 0-IN2088 0
0 15.02.16 CONF PRODUCTION ISSUE adequate ratings, correct installation, operation and maintenance are the DRAWN
CONF
DATE
15.02.16
REV DATE DRAWN REVISION 2.) ALL DIMENSIONS NOMINAL UNLESS OTHERWISE STATED. responsibilities of the system designer and user. Copyright C 2000 BIFOLD FLUIDPOWER LTD. All Rights Reserved C.A.D. Produced Drawing DO NOT Change By Hand
1 2 3 4 5 6 7 8 9 10