1) What is the type of Siamese connection that all 125-millimeter dry standpipes shall be equipped

with?
A. Three-way (Correct Answer)
B. Two-way (Your Answer)
C. Four-way
D. One-way

2) Except on what fixture does the vent pipe opening from the soil or waste pipe must not be below
the weir of the trap?
A. Lavatory
B. Kitchen sink (Your Answer)
C. Bath tub
D. Water closet (Correct Answer)

3) What is the minimum floor area in every storey which is used for habitation, recreation, dining,
study of work and which has an occupied load of not more than 20, wherein a standard automatic
extinguishing system is a
A. 300 sq.m (Your Answer)
B. 200 sq.m (Correct Answer)
C. 400 sq.m
D. 500 sq.m

4) Article 3.2.2.2 of PD 1096 actually allows a Registered Master Plumber to sign and seal plans for
new sanitary installations of more than twenty (20) plumbing units. Aside from being a Registered
Master Plumber what is the other requirement that you must have before you can sign and seal it?
A. A registered engineer (Correct Answer)
B. An engineering graduate
C. Having a minimum experience of 5 years
D. A member of NAMPAP (Your Answer)

5) What is the name of the professional organization for the Registered Master Plumbers here in the
Philippines?
A. National Association of Master Plumbing of the Philippines
B. National Association of Master Plumbers of the Philippines
C. National Master Plumbers Association of the Philippines (Your Answer)
D. National Master Plumbing Association of the Philippines Incorrect

6) In sizing the grease interceptors, four elements are being used. Two of these elements are
number of meals per peak hour and the waste flow rate. What are the other two
elements?
A. Slope and retention time
B. Storage factor and time of concentration
C. Retention time and storage factor (Correct Answer)
D. Percolation rate and time of concentration (Your Answer)

7) If a septic tank has a compartment that exceed 3.7 m in length, what should be the additional
requirement?
A. An additional manhole (Your Answer)
B. Increase the size of the leaching chamber
C. Increase the number of compartments
D. Baffle wall is added
8) According to Batas Pambansa Blg. 344, what type of urinal should be provided for disabled
persons?
A. WALL-HUNG TYPE (Your Answer)
B. PEDESTAL TYPE
C. TROUGH TYPE (Correct Answer)
D. NONE OF THESE

9) According to the Building Code of the Philippines what is the range in height above grade should
the Siamese fire department connection be installed?
A. 30 cm to 1.2 m (Your Answer)
B. 60 cm to 1.5 m
C. 80 cm to 1.8 m
D. 50 cm to 1.0 m

10) How many units do the controversial Article 3.2.2.2 of PD 1096 otherwise known as the National
Building Code limits the practice of Master Plumber?
A. 20 (Your Answer)
B. 10
C. 5
D. 50

11) For a vertical drainage line that is installed to be truly in vertical position, what is the allowed
degree of the branch to be used?
A. 10
B. 45 (Your Answer)
C. 30
D. 60 (Correct Answer)

12)
What is the minimum total net inlet area of roof deck drains on roof deck used as sun decks and
parking decks?
A. Equal to the area of outlet pipe
B. Equal to 4 times the area of outlet pipe
C. Equal to 2 times the area of outlet pipe (Your Answer)
D. Equal to 1 1/2 times the area of outlet pipe Correct

13) What institution standard used as a reference for joining pipes?


A. ASSE
B. ASPE
C. ANSI
D. IAPMO (Your Answer)

14) Which of the following is a prohibited fixture inside a public toilet room?
A. Faucet
B. Drinking fountain (Your Answer)
C. Slop sink
D. Bidet
15) For new, additional or altered plumbing installation not exceeding 20 units, the Building Code
stated that a Licensed Master Plumber could sign and affix his seal on the following engineering
documents except
A. Plumbing plan and layout
B. Design analysis and plans of the original installation (Your Answer)
C. Isometric drawing
D. Guide specifications and bill of materials

16) One of the Code of Ethics for Master Plumber states "Take advantage of a salaried ____ position
to complete unfairly with a practicing Master Plumber." What is the missing word?
A. HIGHER (Your Answer)
B. GOVERNMENT (Correct Answer)
C. PRIVATE
D. COMPETENT

17) Where practical, all pipes from fixtures shall be run in what direction with respect to the nearest
wall or building line?
A. Offset
B. Parallel (Your Answer)
C. Across
D. Perpendicular

18) Which of the following is not included in a plumbing unit?


A. Water Meter (Your Answer)
B. Floor Drain
C. Urinal (Correct Answer)
D. Laundry Tray

19) What is the maximum height should a water closet have if it is intended for a disabled person.
A. 0.40m (Your Answer)
B. 0.50m *
C. 0.45m (Correct Answer)
D. 0.35m

20) The cover of gravity tanks shall be vented using a screened


A. Return bend pipe (Your Answer)
B. Upright pipe
C. Horizontal nipple
D. All of these

21) A fitting for lead-caulked joint that is prohibited when in vertical position
A. Single hub
B. Double hub (Correct Answer)
C. Double tapped tee
D. All of these (Your Answer)

22) In what year did NAMPAP was incorporated as a professional organization?


A. 1935 (Your Answer)
B. 1956
C. 1946
D. 1968
23) Who among the Board Examiners is not a signatory to PRC Resolution 04 that request for the
adoption and promulgation of the Revised National Plumbing Code of the Philippines in 1999?

A. Imelda Perez (Correct Answer)


B. Aida Emely Luz
C. Fortunato Amosco (Your Answer)
D. Jesus Pacheco

24) Who was the first Charter President of NAMPAP?


A. Antonio Mansueto Sr. (Your Answer)
B. Comelio G. Odvina
C. Jesus Tanghal Dera
D. Catalino C. Casupanan (Correct Answer)

25) What Congress of the Republic of the Philippines approved after the third reading Rep. Act 1378
otherwise known as the Plumbing Law of the Philippines?
A. Third Congress (Your Answer)
B. Sixth Congress
C. Second Congress
D. Fifth Congress

26) What type of PVC female screws for water piping is prohibited under the code?
A. Tapped
B. Job fabricated (Your Answer)
C. Seamless
D. Schedule 20 screws

27) What portion of the trap should the vent pipe opening will not go below from a soil or waste
pipe?
A. Slip joint
B. Weir (Your Answer)
C. Sleeve
D. Seal

28) What is the shape for the signage for women's comfort room in order to aid visually impaired
women readily determine whether a washroom is for men or women?
A. CIRCLE (Correct Answer)
B. RECTANGLE
C. TRIANGLE (Your Answer)
D. SQUARE

29) According to the Code, the design of roof gutters is based on the maximum roof area. What is
the shape of the gutter does the design table for storm sewer is being based to?
A. Circular
B. Rectangular (Your Answer)
C. Ovate
D. Semi-circular (Correct Answer)

30) What is the minimum pipe size of the standpipe if the highest outlet is located 23 meters or less
above the Fire Service connection?
A. 3 inches
B. 6 inches (Your Answer)
C. 5 inches
D. 4 inches (Correct Answer)

31) The Building Code stated that all dry standpipe outlets shall be equipped with valves having
substantial chains. What kind of valve is this?

A. Check valve
B. Globe valve (Your Answer)
C. Gate valve (Correct Answer)
D. Ball valve

32) According to Rep. Act 1378 for at leasrt how many years must the appointee to the Board of
Master Plumbers must have been actively engaged in the trade of plumbing?
A. Ten years
B. Eight years
C. Two years
D. Five years (Your Answer)

33) The following are grounds for non-issuance of the certificate of registration by the Board of
Master Plumbers EXCEPT
A. Convicted by court for any criminal offense
B. Of unsound mind
C. Guilty of immoral or dishonorable conduct
D. Failure to pay the required fees (Your Answer)

34) Which of the following is not considered as suds-producing fixture?


A. Kitchen sink
B. Bath tub
C. Washing machine
D. Bidet (Your Answer)

35) When shall the installation of plumbing equipment to supply building or structures from existing
water supply system only be allowed to?
A. If the water demand is inadequate (Your Answer)
B. Whenever the water supply is scantity availbale
C. When there is always water in the main (Correct Answer)
D. When water is not available in the vicinity

36) What kind of concealed connections on fixtures that it is required to provide an access panel or
utility at least 0.30 meter in its least dimension for easy inspection and repair?
A. Slip joint (Your Answer)
B. Ball and socket
C. Hubless
D. Flanged

37) What kind of septic tank is prohibited?


A. CONCRETE (Your Answer)
B. STEEL
C. PLASTIC
D. WOODEN (Correct Answer)

38) What is the minimum number of water closet in a floor level wherein you have to provide 1
water closet for disabled persons as provided by Batas Pambansa Blg. 344? in excess of this number
you have to provide 2.
A. 12
B. 15 (Your Answer)
C. 20 (Correct Answer)
D. 10

39) NAMPAP is a professional organization of Registered Master Plumber under PRC. What is the
PRC accreditation number of NAMPAP?
A. 10
B. 14 (Correct Answer)
C. 18 (Your Answer)
D. 12

40) Under the Accessibilty Law, what is the minimum area of water closet stalls?
A. 1.7 x 1.8 meters (Your Answer)
B. 2.0 x 2.0 meters
C. 1.5 x 1.8 meters
D. 1.2 x 2.0 meters

41) Who was awarded as the most outstanding Registered Master Plumber for the Year 2011?
A. Dave Vela (Correct Answer)
B. Alberto Azarcon (Your Answer)
C. Alberto Cabael
D. Thelma Cardente

42) In the excreta drainage system, which of the following pipe materials should not be used
underground?
A. Vitrified clay pipe
B. Hubless cast iron (Your Answer)
C. Galvanized wrought iron (Correct Answer)
D. None of the above

43) What is the minimum allowable interval for the support of plastic pipes when installed vertically
A. 2ft
B. 5ft
C. 1 meter (Your Answer)
D. 1.5 meter

44) What is the minimum number of approved slip joints fittings may be used on the putlet side of
the trap?
A. Three
B. Two (Your Answer)
C. None
D. One (Correct Answer)
45) In order as not to impede the movement of a person in wheel chair and to have a convenient
access on the lavatory, what is the allowable knee recess vertical clearance that will be provided?
A. 0.50 m to 0.80 m
B. 0.60 m to 0.80 m (Your Answer)
C. 0.40 m to 0.70 m
D. 0.60 m to 0.70 m (Correct Answer)

46) A plumbing permit shall expire and become null and void if the plumbing work authorized
therein if not started for how many days?
A. 30 days
B. 45 days
C. 100 days
D. 365 days (Your Answer)

47) Which of the following is the primary basics for sizing vertical rainwater piping in the Revised
National Plumbing Code?
A. Intensity of rainfall (Correct Answer)
B. Wind direction
C. Slope of roof
D. Roof area (Your Answer)

48) What shape of signage is shown for mens showroom?


A. SQUARE
B. CIRCLE
C. TRIANGLE (Your Answer)
D. RECTANGLE

49) Who shall set the criteria for the quality of drinking water from meteoric, surface or
underground sources?
A. National Water Resources Board
B. Department of Health
C. National Standards for Drinking Water (Your Answer)
D. Department of Environment and Natural Resources

50) When permitted by DENR, which of the following below is NOT used as a basis in determining
the type of the private sewage disposal system to be used?
A. SOIL POROSITY
B. GROUND WATER LEVEL
C. NUMBER OF OCCUPANTS (Your Answer)
D. LOCATION

51) What is the minimum height of raised letters on an iron or bronze sign that will read
"CONNECTION TO DRY STANDPIPE"?
A. 20mm
B. 1/4inch
C. 25mm (Your Answer)
D. 30mm

52) According to Art 3.2.2.2 of PD 1096 what scope of work in plan preparation for new sanitary
installations with more than 20 units does a sanitary engineer differs with a Registered Master
Plumber?
A. Det. all drawings of septic tanks in the absence of disposal field (Correct Answer)
B. Sanitary plan, layout and details (Your Answer)
C. Cost estimate
D. Isometric drawings of roughing in.

53) Unless prohibited by structural conditions, what is the reference of each vertical vent pipes
before offsetting horizontally to join the stack vent or vent stack?
A. Invert of trap
B. Air gap of fixture
C. Water level inside the trap
D. Highest flood level rim of fixture (Your Answer)

54) What installation standard is followed in joining plastic pipe and fittings by solvent cement?
A. ISO
B. ANSI
C. IAPMO (Your Answer)
D. ASHRAE

55) Within how many meters away shall unions be installed from regulating equipment, water
heater, conditioning tank and similar equipment which require removal for servicing or
replacement?
A. 2 ft
B. 1 m
C. 5 ft
D. 0.3 m (Your Answer)

56) Who has the power to remove any member of the Board of Master Plumbers for neglect of duty,
incompetence, malpratice and unprofessional or dishonorable conduct?
A. President of the Philippines (Your Answer)
B. Civil Service Commisioner
C. Chairman of PRC Commisioners
D. Commision on Appointments

57) Who is empowered to administer the provision of Rep. Act 1378?


A. Office of the President
B. Congress of the Philippines
C. The Board of Examiners for Master Plumbers (Your Answer)
D. Professional Regulation Commision

58) Aside from the number of fixture units connected to it, the size of the vent piping is determined
by its
A. Number of inlets
B. Length (Correct Answer)
C. Discharge (Your Answer)
D. Loading

59) Except for plastic piping system, hot and cold water piping may be tested wtih ___
A. 50 psi of the working pressure of the water in the system for at least 15 minutes (Your Answer)
B. 100 psi air for at least 10 minutes
C. 35 psi air for at least 15 minutes
D. 40 psi air or 150 psi water for 10 minutes
60) Aside from galvanized steel, what is the other material for dry standpipe that the Building Code
allows?
A. PVC pipe
B. Wrought iron (Your Answer)
C. PE pipe
D. Brass

61) What is the minimum horizontal clear dsitance from the septic tank to the property line of the
adjoining private property?
A. 1.0 m
B. 1.2 m
C. 1.5 m (Your Answer)
D. 1.8 m

62) Wet venting is applied whenever


A. There are 1 or 2 fixtures at every level (Your Answer)
B. Fixtures are of the same level (Correct Answer)
C. Fixtures are not vented individually
D. None of these

63) If ever pipes are to pass through masonry by using pipe sleeves, how far must each pipe be from
each other?
A. Minimum of three diameters, center to center (Your Answer)
B. Minimum of three diameters flushed from each hole
C. Minimum of 0.15 m on centers
D. Maximum of two diameters flushed from each hole

64) In 1966- 1969, the Board of Master Plumbers and NAMPAP prepared a curriculum for Plumbing
Engineering and approved by the Department of Education. What was the first school that
introduced the Plumbing Engineering curriculum?
A. Feati University (Your Answer)
B. University of the Philippines
C. Mapua Institute of Technology
D. National University

65) According to the Fire Code of the Philippines what is the required slope of all horizontal runs of
dry standpipes system for purpose of drawing?
A. 10%
B. 20% (Correct Answer)
C. 5%
D. 2% (Your Answer)

66) The appropriate sealant that will be used to cover void spaces between pipes and sleeves
through concrete floors in the ground
A. Bitumen (Your Answer)
B. Epoxy
C. Grease
D. Putty

67) Aside from Bell and Spigot, B & S in the code means
A. Ball and Socket
B. Browning and Smith
C. Butt and Soldered
D. Brown and Sharp (Your Answer)

68) What is the minimum age requirement for an appointee to become a member of the Board of
Master Plumbers?
A. Thirty years old (Correct Answer)
B. Twenty eight years old
C. Thirty two years old
D. Thirty five years old (Your Answer)

69) Who is the current chairman of the Board of Examiners for Master Plumber?
A. Fortunato Amosco
B. Virgilio Simbulan (Your Answer)
C. Jessie Mariano
D. Valerin Maogila

70) In accordance to the Building Code, what must be provided in addition to septic tanks by building
located in areas where there is no sanitary sewerage system whenever they will dispose their waste?
A. Baffle plate
B. Subsurface absorption filed (Correct Answer)
C. Imhoff tank
D. Settling chamber (Your Answer)

71) What is the minimum dimension for a turning space in a water closet stall intended for disabled
persons?
A. 2.00 m
B. 1.20 m (Your Answer)
C. 1.00 m
D. 1.50 m (Correct Answer)

72) What is the fee if an expired plumbing permit is renewed?


A. P 150.00
B. Equal to the original fee
C. Double of the original fee
D. 1/2 of the original fee (Your Answer)

73) What is not needed to be installed when a combination standpipe system is installed in
accordance with the Fire Code?
A. Dry standpipe (Your Answer)
B. Wet standpipe
C. Sprinkler system
D. Siamese connection

74) Which of the following plumbing code in USA does the National Plumbing Code of the Philippines
was being patterned for?
A. Standard Plumbing Code
B. ASPE Code
C. Uniform Plumbing Code (Your Answer)
D. International Plumbing Code
75) With what standard specification must all pipe materials must conform to?
A. Product Strandard of the Philippines (Correct Answer)
B. Interational Producers Standard
C. Philippine Standard Council (Your Answer)
D. Department of Trade and Industry

76) Unless serving sinks or urinals, cleanouts may be omitted on a horizontal drain line that is
A. Equal to 2.0 meters
B. Greater than 2.0 meters
C. Less than 1.5 meters (Your Answer)
D. None of these

77) Under what law did plumbing became a duly recognized profession by the Philppine
government?
A. Nat'l Plumbing Code of the Phil of 1959
B. Tydings McDuffie Act of 1905
C. Jones Law of 1907 (Your Answer)
D. Republic Act 1378

78) A kind of cleanout plugs that will be installed in case where raised heads may cause hazards to
passing personnel or vehicles.

A. Depressed
B. Countersunk (Your Answer)
C. Embedded
D. Recessed

79) What kind of joint is not allowed in cast iron pipe?


A. Welded
B. Threaded (Your Answer)
C. Soldered
D. Ball and Spigot

80) What is the masimum length of the fire hose that shall be equipped on wet standpipes?
A. 12 meters
B. 23 meters (Your Answer)
C. 17 meters
D. 25 meters

81) A stack, as defined in the code, is ___


A. The main vent
B. Any vertical vent
C. The horizontal main of soil, waste, or vent stack (Your Answer)
D. The vertical main of soil, waste, or vent piping that extends one or more stories (Correct Answer)

82) Within how many days upon the approval of Rep. Act No. 1378 does it require to have a Board
Examiners for Master Plumbers formed?
A. Thirty days (Correct Answer)
B. Fortyfive days (Your Answer)
C. Sixty days
D. Fifteen days
83) What is the maximum allowable lead content of pipe and fitting for potable piping system?
A. 0% (Your Answer)
B. 2%
C. 5%
D. 8% (Correct Answer)

84) When can a vertical piping be considered to be wet vented?


A. Between openings of vent pipes
B. Between any two consecutive inlet levels (Your Answer)
C. On stack vent
D. When serving two water closets at different levels

85) What shall be issued by the Administrative Authority for the construction of a part of a large
and/or complicated plumbing system before the entire plans and specifications for the whole system
have been submitted or approved?
A. Restraining order
B. Partial permit (Correct Answer)
C. Summon
D. Evaluation sheet (Your Answer)

86) Which of the following could be omitted if the trap arm changes direction that does not exceed
90 degrees?
A. Wye
B. Cleanout (Your Answer)
C. Long sweep
D. Combination of 1/8 bend and wye

87) What is the minimum number of years of experience must a Registered Master Plumber be
before he can be a technical staff of a Building Office?
A. One year
B. Three years (Correct Answer)
C. Two years
D. Five years (Your Answer)

88)Who is authorized to issue rules and regulations to carry into effect the objectives of Rep. Act
1378?
A. Board of Master Plumbers (Your Answer)
B. Congress of the Philippines
C. President of the Philippines (Correct Answer)
D. Professional Regulation Commision

89) What government agency is tasked to set the criteria in the discharge of sanitary sewage from
buildings or pretreated industrial wastewater directly into the nearest sanitary sewer main?
A. National Pollution Control Commission
B. Dept of Environment and Natural Resources (Your Answer)
C. Department of Health
D. Department of Public Works

90) How does a pneumatic tank be designed to supply adequate water pressure in all floors of a
building that will be in accordance with the Building Code?
A. Twice the maximum total dynamic pressure required (Correct Answer)
B. Equal to the total water supply fixture units
C. Twice the total demand per capita
D. Equal to the total dynamic head and minus all the head losses (Your Answer)

91) What is the PRC Resolution Number is issued by the Board of Master Plumbing for the adoption
and promulgation of the Revised National Plumbing Code of the Philippines?
A. Res. No. 2
B. Res. No. 1378
C. Res. No. 4 (Your Answer)
D. Res. No. 962

92) To allow cleaning of the soil and waste line each cleanout should be installed
A. In the direction of flow (Your Answer)
B. Opening upward
C. Vertically above flow line
D. All of these

93) In the water test of the entire plumbing system all openings should be tightly closed except at
A. Producing cleanouts (Your Answer)
B. Highest opening (Correct Answer)
C. Stack vent
D. Bleeders

94) A type of drainage and venting system with universal branch line that is prohibited
A. Single (Correct Answer)
B. Dual
C. Dependent (Your Answer)
D. Alternate

95) Of the four board subjects given for Master Plumbers examination, which of this subject was
originally split into two subject?
A. Practical Problems (Correct Answer)
B. Design And Installations (Your Answer)
C. Plumbing Code
D. Plumbing Arithmetic

96) For at least how many working days shall a required for inspection of the plumbing works be
filed before such inspection be intended?
A. 7 working days
B. 5 working days
C. 3 working days (Your Answer)
D. 10 working days

97) What should be done whenever a partition contains some piping and runs parallel to the floor
joist underneath?
A. Notching should be introduced into the joist (Your Answer)
B. Adjust the joist to make it perpendicular with the direction of pipe
C. Space the joist wider to accommodate the pipe
D. Double the joist (Correct Answer)
98) PD No. 1185 is another law that Master Plumbers used as their guide in the practice of the
plumbing profession.What is PD No. 1185?
A. Accessibilty Law
B. Fire Code of the Philippines (Correct Answer)
C. Water Code of the Philippines (Your Answer)
D. Code of Sanitation

99) To what provision does the design, construction and operation of deep wells for the abstraction
of ground water will have to follow?
A. National Plumbing Code of the Philippines
B. National Standards for Drinking Water
C. Water Code of the Philippines (Your Answer)
D. Code of Sanitation

100) What is the minimum pipe size of the standpipe if the highest outlet is located more than 23
meters above the Fire Service connection?
A. 3 inches
B. 6 inches (Correct Answer)
C. 5 inches
D. 4 inches (Your Answer)

101) If the discharge of a fixture or drain may contain solids or semisolids heavier than water that
would be harmful to the drainage system or cause stopaage within the system, where the discharge
must pass first?
A. Sand interceptor (Correct Answer)
B. Screen wire mesh (Your Answer)
C. Wooden baffle

102) Whenever the piping is pressurized by a pump or ejector, what kind of pipe should not be used
in the excreta drainage system?
A. Vitrified clay pipe (Correct Answer)
B. Hubless cast iron
C. Galvanized wrought iron (Your Answer)
D. None of these

103) The following are the data required whenever a Registered Master Plumber sign the blueprint
of the building plan EXCEPT
A. Date of PRC registration
B. PTR date
C. Registration expiry date (Your Answer)
D. None of these

104) Building sewers shall be tested by completely filling the sewer with water from the ___
A. Lowest to the highest point (Your Answer)
B. Lowest to at least ground level
C. Lowest to at least a 10-foot head
D. Lowest to at least a 5-foot head

105) What is the maximum distance as where supports of vertical cast iron soil pipes are made?
A. Every 3.0 m
B. Every meter
C. Every storey (Your Answer)
D. Every joint

106) Where should the overflow pipe lead for overhead tank installed on buildings?
A. Soil stack
B. Scuppers
C. Storm drain (Your Answer)
D. Gutter

107) What is the minimum diameter of vent pipe is allowed in the revised Code?
A. 1 inch
B. 1 1/4 inch (Your Answer)
C. 2 inch
D. 1 1/2 inch

108) For how many days shall the revised National Plumbing Code will take effect following its
complete publication in the Official Gazette?
A. 100 days (Correct Answer)
B. 60 days (Your Answer)
C. 50 days
D. 30 days

109) What is the maximum water pressure must standpipe fittings and connections must withstand
to when ready for service?
A. 21 kg/cm (Correct Answer)
B. 34 kg/cm
C. 15 kg/cm
D. 8 kg/cm (Your Answer)

110) Where the number of water closets in a floor level exceeds 20, how many of these shall be
provided to the disabled persons?
A. 1
B. 2 (Your Answer)
C. 3
D. 4

111) The minimum requirement for the slope of horizontal drainage pipes between manholes is
A. 2% (Your Answer)
B. 2 1/2%
C. 3%
D. 4%

112) For the hot and cold water distribution system, on what side should the hot water supply be
placed in combination fittings?
A. Left (Correct Answer)
B. Right
C. Center (Your Answer)
D. None of these

113) Drainage piping serving fixtures located below the crown level of the main sewer shall
discharge into an approved water tight
A. Septic tank
B. Sump (Correct Answer)
C. Cesspool
D. Leaching tank (Your Answer)