DISEO DE PUENTE CON VIGAS POSTENSADOS (VIGAS AASHTO) Ver tabla 2.5.2.6.

3-1 (LRFD 2010)


1) Predimensionamiento de la seccion:
Luz = 25.8 m 1 Vereda 1.2 m
fcviga = 350 kg/cm2 N carriles 2
fy = 4200 kg/cm2 Calzada 9 m
P. esp. ASF. = 2200 kg/m3 Ancho puente 11.4 m
P. esp. C = 2400 Kg/m3 Carpeta asfaltica 0.0508 m
fpu 18984 kg/cm2 270 KSI
fcilosa = 280 kg/cm2 STRANDS Diametro= 1/2 Pulgadas
R= 0.85 perdida de 15% A = 0.196 pulgadas 2
1.1) Predimensionamiento Tablero 1.267 cm2
Ver tabla 2.5.2.6.3-1 (LRFD 2010)
Ver tabla 4.6.2.2.2b-1 (LRFD 2010) (ASUMIR RANGOS)
S= 2 m criterio
ts = 0.2 m por tabla
L= 25.8 m
Nb = 4 generalmente son 4 (evitar peraltamiento)
Seccion Transversal Puente

ANCHO DEL PUENTE

vereda
Altura Branda

carril carril vereda

B ts

ANCHO VEREDA
S S S
E ALTURA VIGA

S S S
extremo extremo
b b b b
TABLA n3
Vereda = 1.20 m ts = 0.2 m
CARRIL = 4.50 m E= 1.5 m
Ancho puente 11.40 m
Extremo = 2.33 m
S= 2.00 m
b= 0.75 m ancho menor viga (funcion tipo de viga TABLA n3)
h= 1.30 m altura viga (funcion tipo de viga TABLA n3) criterio
B= 1.10 m ancho mayor viga (funcion tipo de viga TABLA n3)
S = 1.25 m
Anc. Ver. 0.25 m criterio
Alt.baran. 1.00 m criterio
Nb = 4.00 criterio
*) VIGA DIAFRAGMA
espaciamiento entre vigas S = L / N diafragmas S = 8.6 m
N diafragmas = 3 criterio generalmente en postensado

peralte diafragma = h viga principal - 0.25 1.05 m


1.2 m criterio
ancho diagragma = 0.25 m criterio

1.2) Predimensionamiento Viga Postensado


Metodo Johannes Johanson
h = L /15 o L /20 h =L/15 1.72 h=L/20 1.29
H ASUMIDO = 1.5 m CORROBORA LA ALTURA DE NUESTRA VIGA
b= 0.75 m DE DISEO

2) PROPIEDADES DE LA SECCION

y1 = Aiyi/Ai 0.5503 m
y2 = H - y1 0.9547 m
SECCION COMPUESTA ( VIGA + LOSA)
TIPO b(m) h(m) yi(m) Ai(m2) Aiyi(m3) Inerc.(m4) Ai*(y1-yi)2
I 1.79 0.2 0.1 0.358 0.036 0.00119 0.0726
II 1.1 0.12 0.26 0.132 0.034 0.00016 0.0111
III 0.2 1.03 0.835 0.206 0.172 0.01821 0.0167
IV 0.75 0.15 1.425 0.113 0.160 0.00021 0.0861
V 0.275 0.25 1.267 0.069 0.087 0.00036 0.0353
VI 0.325 0.08 0.347 0.026 0.009 0.00001 0.0011
VII 0.13 0.1 0.433 0.013 0.006 0.00001 0.0002
SUMATORIA 0.916 0.504 0.02016 0.2231

y1 = Aiyi/Ai 0.642 m
y2 = H - y1 0.658 m

SECCION NO COMPUESTA ( VIGA )


TIPO b(m) h(m) yi(m) Ai(m2) Aiyi(m3) Inerc.(m4) Ai*(y1-yi)2
II 1.1 0.12 0.06 0.132 0.008 0.00016 0.0447
III 0.2 1.03 0.635 0.206 0.131 0.01821 0.0000
IV 0.75 0.15 1.225 0.113 0.138 0.00021 0.0383
V 0.275 0.25 1.088 0.069 0.075 0.00036 0.0137
VI 0.325 0.08 0.147 0.026 0.004 0.00001 0.0064
VII 0.13 0.1 0.233 0.013 0.003 0.00001 0.0022
SUMATORIA 0.558 0.358 0.01896 0.1052
2.1) PROPIEDADES DE LA SECCION COMPUESTA
Propiedades de la Seccion Distancias al nucleo Modulos de seccion
A(m2) Icg(m4) r2(m2) y1(m) y2(m) k1(m) k2(m) s1(m3) s2(m3)
0.916 0.2469 0.2695 0.5503 0.9547 0.2823 0.4897 0.4487 0.2586

r2 = 0.2695 K1 = 0.2823 K2 = 0.4897 I= 0.2469

ef = 51.29 % OK

2.2) PROPIEDADES DE LA SECCION NO COMPUESTA


Propiedades de la Seccion Distancias al nucleo Modulos de seccion
A(m2) Icg(m4) r2(m2) y1(m) y2(m) k1(m) k2(m) s1(m3) s2(m3)
0.558 0.1473 0.2639 0.6416 0.6584 0.4009 0.4113 0.2296 0.2238

ef = 53.96 % OK
3) CALCULO DE FUERZAS ACTUANTES "Mo" y M(d+l):
3.1) Cargas iniciales Mo ( Peso propio de vigas + diafragama)
a) Peso Propio (DC1)
Ai * Peso Especifico Concreto
Peso de la losa + Viga 0.916 * 2400 2199 Kg/m
DC = 2.20 tn/m
182.97 Ton-m

Peso de la viga 0.558 * 2400 1339.80 kg/m


1.340 ton/m
111.48 ton-m
b) Peso Propio de la Viga Diafragma (DC2) METODO

Peso de Viga Diafragma = 0.25*(peralte diagrafma-ts)*S


= 0.9000
Calculo Reaccion = (Peso viga diafragma * Napoyos)/2
= 1.80 ton

0.9 ton 0
0.9 ton 0.9 ton 0.90

8.6 8.6 8.6

25.8 m
1.80 ton 1.80

7.74 ton-m

190.71 ton-m Para seccion compuesta


111.48 ton-m Para seccion simple sin Losa
3.2) Cargas Aplicadas M(d+l)
a) Carga de Asfalto (DW)

= 0.25 ton/m
20.59 ton-m
b) Carga Viva Vehicular : HL-93K (LRFD)
b.1) Calculo del momento por flexion:
Para el CAMION de Diseo CARGA VIVA (LL)

14.515 ton 14.515 ton 3.62 ton

8.630 4.27 4.27 8.630

y1 = 4.315 y = 6.450 y2 = 4.315

12.900 12.900

25.80

CARGA VIVA (LL) = 171.87 ton-m


EFECTO DINAMICO = 33% 56.72 ton-m
MLL+IM = 228.59 ton-m

Sobre Carga Distribuida MLL+IM

0.952 ton/m
0.000
25.80 m

MLL+IM = 79.21 ton-m

= 307.80 ton-m

c) CALCULO DEL FACTOR DISTRIBUCION DEL MOMENTO EN VIGA INTERIOR

2.00

0.2

eg = 0.85 I= 0.137 m4
1.3 1.5 A= 0.975 m2

0.75
Parametros de Rigidez Longitudinal
= 8.50E+11 mm4
n= 1 Modulo de los MATERIALES
Nb = 4
C = 11400 mm ancho total puente
S= 2000 mm separacion vigas
L = 25800 mm longitud del puente
ts = 200 mm espesor losa
(Kg/L * ts3) 4.116243 mm4 baranda metalica
Por un Momento Flector
Un carril cargado
g= 0.454

Dos Carriles

g= 0.628

Por lo tanto se utilizara


VIGAS INTERIORES = g = 0.628

Momento de Diseo
MHL-93 Viga Interior 193.22 ton-m MLL+IM * g
M(d+l) = Viga Interior 213.81 ton-m (MLL+IM * g) + peso asfalto

d) RESUMEN DE CARGAS DE DISEO


Mo = 190.71 ton-m Momento De cargas permanentes
M(d+l) = 213.81 ton-m Momento de Camion HL-93, S/C ; asfalto
Mt = 404.52 ton-m

5) CALCULO DE ESFUERZOS PERMISIBLES:


5.1) Esfuerzos iniciales de Transferencia
a) Fibra superior
De acuerdo a tabla 5.9.4.1.2-1 LRFD 2010 tenemos:
fti 13.387 kg/cm2 <= 14.0 Kg/cm2 OK

b) Fibra Inferior
De acuerdo a la Tabla 5.9.4.1.1-1 LRFD 2010 tenemos:
-168.0 kg/cm2 fci

5.2) Esfuerzos en Servicio


a) Fibra Superior
CASO I: CARGA TOTAL
De acuerdo a la tabla 5.9.4.2.1-1 LRFD 2010 tenemos

1 VER TABLA asumiendo


fcs= -210 kg/cm2

CASO II: Sobrecarga y semisuma de Preesforzado + cargas permanentes

fcs = -140 Kg/cm2

b) Fibra Inferior:
De acuerdo a la Tabla 5.9.4.2.2-1 LRFD 2010; Indica que no debe existir traccion :
fts = 0 Kg/cm2

5) MODULOS DE SECCION REQUERIDOS

S1 = 109503.15 cm3

S2 = 169759.47 cm3

COMPARAMOS:
S1 = 448685.9 cm3 > 109503.15 cm3 SECCION ADECUADA
S2 = 258614.0 cm3 > 169759.47 cm3 SECCION ADECUADA

6) CALCULO DE LA EXCENTRICIDAD DE LOS CABLES Y FIERZA INICIAL EN EL CENTRO


Para esta parte vamos a utilizar las inecuaciones de Magnel para determinar la excentircidad las
unidades que se utilizaran en cm.

1 e - 48.97
>
P1 25077141.02

1 e + 28.23
>
>
P1 62517931.29

1 e + 28.23
<
P1 47590370.22

1 e - 48.97
<
P1 -63261451.52
PARA LA GRAFICA TABULACION
a continuacion vamos a realizar la tabulacion de las inecuaciones de Magnel y se graficara para poder Ec.1 "1/P" Kg Ec.2 "1/P" Kg Ec.3 "1/P" Kg Ec.4 "1/P" Kg
determinar la excentricidad maxima y minima: -31.49 -0.28 -0.37 12.48
VALORES DE 1/P MULTIPLICADOS 10000000 SOLO PARA LA GRAFICA -27.50 1.32 1.73 10.90
-23.52 2.92 3.83 9.32
e(cm) Ec.1 "1/P" Kg Ec.2 "1/P" Kg Ec.3 "1/P" Kg Ec.4 "1/P" Kg -19.53 4.51 5.93 7.74
-30 -3.15E-06 -2.84E-08 -3.73E-08 1.248E-06 -15.54 6.11 8.03 6.16
-20 -2.75E-06 1.316E-07 1.728E-07 1.09E-06 -11.55 7.71 10.13 4.58
-10 -2.35E-06 2.915E-07 3.83E-07 9.322E-07 -7.56 9.31 12.23 3.00
0 -1.95E-06 4.515E-07 5.931E-07 7.741E-07 -3.58 10.91 14.34 1.42
10 -1.55E-06 6.114E-07 8.032E-07 6.16E-07 0.41 12.51 16.44 -0.16
20 -1.16E-06 7.714E-07 1.013E-06 4.579E-07 4.40 14.11 18.54 -1.74
30 -7.56E-07 9.313E-07 1.223E-06 2.999E-07 8.39 15.71 20.64 -3.32
40 -3.58E-07 1.091E-06 1.434E-06 1.418E-07 12.37 17.31 22.74 -4.91
50 4.11E-08 1.251E-06 1.644E-06 -1.63E-08 16.36 18.91 24.84 -6.49
60 4.40E-07 1.411E-06 1.854E-06 -1.74E-07 20.35 20.51 26.94 -8.07
70 8.39E-07 1.571E-06 2.064E-06 -3.32E-07 24.34 22.11 29.04 -9.65
80 1.24E-06 1.731E-06 2.274E-06 -4.91E-07 28.32 23.71 31.15 -11.23
90 1.64E-06 1.891E-06 2.484E-06 -6.49E-07 32.31 25.31 33.25 -12.81
100 2.03E-06 2.051E-06 2.694E-06 -8.07E-07 36.30 26.91 35.35 -14.39
110 2.43E-06 2.211E-06 2.904E-06 -9.65E-07 40.29 28.51 37.45 -15.97
120 2.83E-06 2.371E-06 3.115E-06 -1.12E-06 44.28 30.11 39.55 -17.55
130 3.23E-06 2.531E-06 3.325E-06 -1.28E-06 48.26 31.71 41.65 -19.13
140 3.63E-06 2.691E-06 3.535E-06 -1.44E-06 52.25 33.31 43.75 -20.71
150 4.03E-06 2.851E-06 3.745E-06 -1.6E-06
160 4.43E-06 3.011E-06 3.955E-06 -1.76E-06
170 4.83E-06 3.171E-06 4.165E-06 -1.91E-06
180 5.23E-06 3.331E-06 4.375E-06 -2.07E-06

GRAFICA DE LAS INECUACIONES DE MAGNEL

1/P
60.00 y = 0.3988x - 19.528
(1)
50.00
y = 0.2101x + 5.9309
40.00 (3)

30.00 y = 0.16x + 4.5147


(2)
20.00

e.max.realx emax.x Ec.1


10.00
e (cm) Ec.2
0.00 Ec.3
-50 0 50 100 150 200
Ec.4
-10.00 emin.x
Lineal (Ec.1)
-20.00 Lineal (Ec.2)
y = -0.1581x + 7.7409 Lineal (Ec.3)
-30.00 (4)
Lineal (Ec.4)
-40.00

Y = mX + b
Ecuacion 1 Y1: 0.3988 x + -19.528
Ecuacion 2 Y2: 0.1600 x + 1.515
Ecuacion 3 Y3: 0.2101 x + 5.931
Ecuacion 4 Y4: -0.1581 x + 7.758

Igualando la Ecuacion 1 con ecuacion 3 obtenems emax = 134.92 cm maximo teorico


Igualando la Ecuacion 3 con ecuacion 4 ontenemos emin = 4.96 cm Minimo teorico
Finalmente la distancia entre el eje del cable y la fibra extrema lo tomaremos como el 0.10h, este valor
aproximado

20
55.03 cm = Y1
E.N
150.5 cm
emax real = 80.47
95.47 cm = Y2
z= 15

Ducto para cables


z = h/10 = 15 cm

El valor de la "E real" maxima se reemplazar en la Ecuacion (3) de Magnel y obtendremos la FUERZA DE
TENSADO "P"
e max real = 80.47 cm
1 1
= 2.28E-06
Pi kg

Pi = 437.83 ton Fuerza de Tensado

7) ESTADOS LIMITES APLICABLES


De acuerdo a la Tabla 3.4.1-1 del AASHTO-LRFD tenemos las siguientes
ecuaciones de resistencia

8) COMPROBACION DE ESFUERZOS EN EL CENTRO DE LA LUZ


Pi = 437825.5 kg
A comp. = 9162.500 cm2 S compuesta S simple
A simp. = 5582.500 cm2 S1= 448685.9 cm3 S1= 229617.2 cm3
emax..real= 80.47 cm S2= 258614.0 cm3 S2= 223777.9 cm3
R= 0.85
R*Pi = 372151.7 kg M(d+l) = 213.81 ton-m Mt = 404.52 ton-m
Mo = 190.71 ton-m Mpp = 111.48 ton-m M.asf = 20.59 ton-m
Mi = 193.22 ton-m

8.1) ESTADO DE SERVICIO I


En condiciones iniciales de servivio : Tensado de la Viga sin losa
Fibra Superior (ecuacion I)

fti= 0 Kg/cm2 < fti admisible = 13.387 kg/cm2


Seccion en Compresion Seccion en Traccion OK

Fibra Inferior (Ecuacion II)

fci= -150.65 Kg/cm2 < fci admisible = -168 kg/cm2


Seccion en Compresion Seccion en Compresion OK

En condiciones finales de servicio: Viga con cargas permanentes + trafico


P = R * Pi = 372151.7 kg

CASO I (Carga Total)


Fibra Superior (Ecuacion III) con carga total

fcs= -112.41 Kg/cm2 < fci admisible = -210 kg/cm2


Seccion en Compresion Seccion en Compresion OK
CASO II (Sobrecarga y Semisuma de presforzado +carga permanente)

fci= -98.28 Kg/cm2 < fci admisible = -140 kg/cm2


Seccion en Compresion Seccion en Compresion OK

Fibra Inferior (Ecuacion V)

fts= -19.72 Kg/cm2 < fts admisible = 0 kg/cm2


Seccion en Compresion Seccion NO genera Traccion OK

8.2) ESTADO DE SERVIVIO III


En condiciones iniciales de servivio : Tensado de Viga + losa
Fibra Superior (Ecuacion I)

fti= -11.7641 Kg/cm2 < fti admisible = 13.387 kg/cm2


Seccion en Compresion Seccion en Traccion OK

Fibra Inferior (Ecuacion II)

fci= -110.28 Kg/cm2 < fci admisible = -168 kg/cm2


Seccion en Compresion Seccion en Compresion OK

En condiciones finales de servicio: Viga con cargas permanentes + trafico


P = R * Pi = 372151.7 kg

CASO I (Carga Total)


Fibra Superior (Ecuacion III) con carga total
fcs= -55.42 Kg/cm2 < fci admisible = -210 kg/cm2
Seccion en Compresion Seccion en Compresion OK

CASO II (Sobrecarga y Semisuma de presforzado +carga permanente)

fci= -44.93 Kg/cm2 < fci admisible = -140 kg/cm2


Seccion en Compresion Seccion en Compresion OK

Fibra Inferior (Ecuacion V)

fts= -14.94 Kg/cm2 < fts admisible = 0 kg/cm2


Seccion en Compresion Seccion NO genera Traccion OK

8.3) NUMERO DE STRANDS REQUERIDOS POR VIGA


Con Strands de Diametro = 1/2 pulgadas A = 0.196 pulgadas2
fpu = 18984 kg/cm2 1.267 cm2
fpi = 13288.8 kg/cm2 fpi= 0.7fpu ; considerado tabla 5.9.3-1 AASHTO-LRFD

La capacidad tomada para un STRANDS sera de :


fpi = 13288.8 kg/cm2 para STRANDS de 1/2 pulg.
capacidad = 16833.84 Kg
con Pi = 437.83 ton (centro de Luz)
P = R*Pi P = 372.15 ton N Strands = 23.00 STRANDS de 1/2 pulgadas
P * 1000
capacidad
9) VERIFICACION POR ESTADO DE RESISTENCIA I
Calculamos el momento aplicado

Mu = 643.44 ton-m
Calculamos el momento resistente de la viga
Se determina la profundidad del bloque de compresion de acuerdo C5.7.3.2.2 del ASSHTo -
LRFD teniendo la siguiente expresion:

fpy = 17085.6 kg/cm2 TABLA C5.7.3.1.1-1


fpu = 18984 kg/cm2
fpe = 12773.06 kg/cm2 > 0.50*fpu= 9492 kg/cm2 OK fpe= P*1000 Aps
B1 = 0.8
K= 0.28 para cables de baja relajacion de la Tabla C5.7.3.1.1-1 AASHTO-LRFD
h-z= dp = 135.5 cm distancia desde la fibra extrema en compresion al centroide del tendon de presfuerzo
Aps = 29.14 cm2 are de acero de Presfuerzo Aps = N Strads*A acero(cm2)
b= 200.00 cm ancho del patin

C= 9.120791 cm < hf = 20 cm OK
espesor losa
Por lo tanto la seccion se esta comportando como seccion "RECTANGULAR"
El esfuerzo promedio en el acero de presfuerzo es :

fps = 18626.2 kg/cm2


El bloque de compresion esta dado por a = CxB1, por lo tanto:
a= 7.30 cm

Finalmente el momento RESISTENTE estara dado por la siguiente Expresion:

especificado en 5.7.3.3.3-1 AASHTO - LRFD

Mn = 716 ton-m > Mu = 643.44 ton-m


OK
La seccion esta cumpliendo con la norma AASHTO - LRFD
Ver tabla 4.6.2.2.2b-1 (LRFD 2010)
ton

ton
8.630
0.000

Anda mungkin juga menyukai