Schindler 3100

A cost-effective, MRL traction elevator


for two- to three-story buildings

Schindler Passenger Elevators


2 Schindler 3100
The Schindler 3100 is
a competitively-priced,
machine room-less (MRL)
traction elevator that
outperforms hydraulic alternatives

Sustainable
Advanced energy-saving design is up to 60% more efficient
than hydraulic elevators.

Smooth
Superior traction engineering provides passengers with a
noticeably more comfortable and quieter ride.

Spacious
Installs in a standard hydraulic hoistway while delivering
larger cabs and more usable building space.

Smart
More efficient planning, ordering, delivery and installation
processes shorten lead times.

Sophisticated
Carefully selected design palettes can be configured to
complement any building dcor.

Schindler 3100
3
The MRL traction elevator youve
been waiting for optimized for
two- to three-story buildings
If hydraulic elevators have been the workhorses of the low-rise market,
the Schindler 3100 is a comparably priced traction thoroughbred.
Its easy to order, simple to install, a pleasure to ride, provides space and
energy saving, and of course its reliable and safe.

An enlightened elevator Performance and value


The Schindler 3100 is the smart choice for two- or The Schindler 3100 is MRL traction solution that
three-stop commercial and residential buildings. Thats provides all the benefits of our highly regarded
because it is engineered like no other low-rise elevator. Schindler 3300 but configured cost-effectively for the
It offers a distinctive range of design and aesthetic low-rise two- and three-story market. It delivers the
options along with an amazingly smooth performance same level of product quality, easy installation and
that uses less energy, makes less noise and fits easily safe, reliable service.
into a traditional hydraulic elevator hoistway.

Fast facts MRL Traction vs. MRL Hydraulic


Capacity 2100 3500 lbs., 14 23 passengers Traction Hydraulic
Travel height Max. 48, max. 3 stops, 3 front, 3 rear Energy efficient
Door width 36 42 inches
Eco-friendly
Door height 84 inches
Space saving
Drive Gearless/frequency controlled
Speed 100 FPM Smooth ride

Control Selective collective Low noise


Interior Powder coat, plastic laminate No odor
or brushed stainless steel
Large cab
Compliance Meets applicable federal, state and local codes.
(Check with your local sales representative Fits standard hoistway
for details.) Affordably priced

4 Schindler 3100
The design efficiencies of
the Schindler 3100 MRL
traction elevator reduce its
overall space requirements
by as much as 20%.

Schindler 3100
5
Sustainable
The Schindler 3100 is significantly more eco-friendly than hydraulic elevators.

More Efficient
Up To 60 %
Than Hydraulic
Elevators

Drive Control
Compact, lightweight and durable design When not in use, car lights automatically switch to
Gearless machine saves energy and avoids standby mode
power loss Car panel and floor indicators use low power LEDs
Stable start uses energy more efficiently and Multi-bus control architecture reduces cabling and
reduces electric costs material waste
Frequency converter with standby power mode Smart controls provide more efficient passenger
safely returns elevator to nearest floor during transportation.
power outage.
Cab
Car lighting uses energy-efficient CFL lamps
Central guiding system reduces friction and energy
consumption
Door drive with standby mode uses less electricity
Larger cabs are also stronger and lighter weight.

Schindler is a member of the


U.S. Green Building Council
and supports the LEED

Green Building Rating System.

6 Schindler 3100
Smooth
Traction elevators offer smoother performance than hydraulic elevators
smoother starts, stops and between-floor travel.

Schindler 3100 cabs


The Schindler 3100 uses a unique frameless cab design
that reduces system weight, energy consumption and
installation times. Constructed using high-quality,
high-strength materials they are more stable, quieter
and roomier for increased passenger comfort.
Lighter cabs also require less operating power and
consume less energy.

Suspension traction media (STM) Traction sheaves and hoist machines


Consisting of strong, surfaced-coated steel wire ropes Combining lighter cabs with more efficient drives and
sheathed in a non-circular, polyurethane jacket, the more flexible STM allows for the use of significantly
Schindler suspension traction media (STM) is quieter, smaller, space-saving sheaves. The innovative tooth
stronger, and more flexible than traditional steel design of the lightweight STM engages tightly into the
cables. Weighing less, they require less power and grooves of the pulley to insure a smooth ride, less wear
energy to operate. and a longer lifespan.

Schindler 3100
7
Spacious
The compact design of the Schindler 3100 eliminates the need for a separate
machine room, delivers cabs that are 5% larger on average and leaves more
usable building space.

More room is always better


The reduced space requirements for technical
equipment and components enable the Schindler 3100
to deliver significant advantages:
Fits into a standard hydraulic hoistway
Requires no machine room or control closet
Needs minimal hoistway overhead
Eliminates unsightly roof structures.

Space-saving measures include:


Small, powerful drive located in the hoistway
overhead
High-strength, flexible suspension traction
media (STM)
Compact inspection and test panels in the top
landing hoistway door jamb
Control distributed throughout the system
The Schindler 3100 does not require a space-
consuming machine room or control closet.
However, some jurisdictions still require such space.
In those areas please contact your local Schindler
sales representative for a room or closet solution.

The Schindler 3100 gives you


more usable building space
while reducing construction costs.

Photo top: The advanced Schindler 3100 MRL traction elevator


fits seamlessly into a standard hydraulic elevator hoistway.

Photo middle: A small gearless traction machine with best in class


motor efficiency and performance is at the heart of the
Schindler 3100 MRL design.

Photo bottom: The Schindler 3100 inspection and test panel is


incorporated into the doorframe at the top floor eliminating the
need for an additional control cabinet.

8 Schindler 3100
Smart
From planning through installation, youll find our processes are streamlined,
simplified and quick.

Planning Ordering
The Schindler 3100 requires no machine room. The design of the Schindler 3100 is sophisticated,
For you, this means less planning. Only one space, yet simple. The key factors are quickly established.
the elevator shaft, has to be designed. Standardized Since there are no complicated specifications, it is
plans simplify the process, making it fast and easy to place an order. You will quickly and effortlessly
efficient. find the product that fits your needs.

1 2

3 4

Delivery Installation
We deliver the Schindler 3100 complete and The elevator is quickly installed. No cranes or
all at once, just in time for when the building scaffoldings are required. The system is ready in
is ready for the elevator installation. about two weeks. Our well-thought-out process
makes all the difference.

Schindler 3100
9
Sophisticated
Our design palette is simple, yet refined. It keeps lead times and costs down but
your artistic expression high.

Design palette elements


Cab walls are available in brushed stainless steel,
powder coat or a choice of plastic laminates.
The ceiling design is available in brushed stainless
steel or silver-metallic powder coat.
Ceiling lighting is refined, yet illuminating using
long-lasting, energy-efficient CFL bulbs.
Landing doors are available in brushed stainless
steel, various colors of durable powder coat or
primer.
Doors are available in center-opening and left or
right side-opening.
Hall fixtures are brushed stainless steel with
tempered safety glass.

Note: The car specifications, options and colors in this


brochure are representative only and are subject to
change. Samples shown may vary from the original in
color and material.
Laminate Long Beach Blue

Brushed stainless steel

10 Schindler 3100
Landing doors Available in 11 powder coat colors or stainless steel Hall fixture Car fixture

Ceiling lighting Handrails

Schindler 3100
11
Premium Finish Options

The Schindler 3100 gives you a wide selection of


durable powder coat or colorful laminate finishes,
as well as a sleek brushed stainless steel cab.
From the fun, fresh colors of Tribeca to the
subdued natural tones of Willamette, create a
look and feel that is truly one of a kind.

Tribeca
Fresh, flashy and multifaceted

Memphis Grey Montreal Blue Havasu Beige Napa Burgundy

Edmonton White Sarasota Yellow Tucson Orange Tupelo Taupe - Primer

Montreal Blue Powder coat colors

South Beach
Warm, distinguished and genuine

Omaha Yellow Kansas City Kiwi Seattle Sprout Tampa Tangerine

Phoenix Sunset Long Beach Blue Portland Purple

Tampa Tangerine Matte finish laminates with subtle, wavelike design

12 Schindler 3100
River Walk
Clean, cool and cutting edge

Winnipeg Frosted Glass Houston Sea Glass Miami Bottle Glass

Mesa Mercury Glass Boston Antique Glass

Mesa Mercury Glass Matte or gloss finish laminates with glassy sheen;
swatches are a representation of the gloss finish.

Great Lakes
Steely, sophisticated and elegant

Toronto Grey Milwaukee Pewter

Pittsburgh Steel Chicago Carbon Brushed stainless steel

Toronto Grey Choose from gloss finish laminates with subtle, monochromatic patterns
or a distinctive brushed stainless steel cab.

Willamette
Rich, natural and classic

Raleigh Blonde Washington Cherry Baltimore Cherry

Shaker Heights Cherry Columbia Walnut New York Night

Baltimore Cherry Matte and gloss finish laminates with rich, wood-grain colors;
swatches are a representation of the gloss finish.

Schindler 3100
13
Striking Details

Entrances and cab details are available in durable


powder-coated and stainless steel finishes. Mix or
match entrances and landing doors finishes as desired
and make the statement that suits your design.

Memphis Grey Montreal Blue Havasu Beige Napa Burgundy Edmonton White Sarasota Yellow

Tucson Orange Cleveland Satin Jacksonville Bronze Denver Ivy Tupelo Taupe (Primer) Brushed Stainless Steel

14 Schindler 3100
Intelligent Performance

The Schindler 3100 enhances rider experience,


improves safety and minimizes downtime.

Control
The control system is based on low-energy
multiprocessor technology. The compact main
inspection and test panel of the decentralized system
is integrated in the doorjamb.

Control functions
Miconic NX microprocessor
On-board diagnostics, self-testing
Light curtain
Overload detection
Two-way, hands-free emergency communication
Firefighters Service operation
Independent service
Automatic car light.

Schindler Direct
Supports Schindler predictive maintenance,
anticipating difficulties before they occur and
allowing rapid response to service calls.

Fixtures
The combination of back-printed white glass and
stainless steel give the elevator a contemporary,
modern look while meeting all applicable codes.

Schindler 3100
15
Service

With Schindler Service you can be confident


of fewer callbacks, fewer inconveniences
and less downtime.
SCS
N

Why Schindler Service is better


Dig
Tooital
Schindler technicians receive over 50 hours of lcas
e
ned
training every year to keep their skills sharp and Traiicians
hn
current. Using their FieldLink digital device, they can Tec
resolve issues quickly by accessing the Schindler Digital
Toolcase, a database of experience-based solutions. Sch
in
Diredler
ct
Schindler Direct wireless connectivity allows us
to monitor your equipment 24/7 and provide error
and shutdown protection, prioritized solutions and
advanced data collection, which gives you 20%
improvement in first-time fixes, up to 32% faster return
to service, and up to 33% reduction in service calls.
Plus, Schindler Direct can help eliminate Running on
Arrival (ROA) charges.

If an issue does arise, one toll-free call to


1.800.225.3123, the Schindler Customer Service
Network (SCSN), connects you to a dedicated rd
boa
customer support team any time, day or night. This ash
er D
tom
direct communication and personalized service helps Cus
oard
Dashb e
quickly resolve your problem. Mobil

Genuine manufacturers replacement parts from


extensive local and national inventories are available
within 24 hours to help expedite repairs.

Schindler Dashboard and Dashboard Mobile


keep you advised on how your building is performing,
even when everythings running smoothly. And when
youre ready to drill deeper, you can track trends, view
performance reports and service records in real time.

16 Schindler 3100
Schindler 3100 MRL Traction Elevator
General Purpose
Standard Speeds: 100 (0.5 m/s)
Openings: 3 front, 3 rear
Travel: Up to 48 (14.6 m)

Machine room-less traction elevator with frequency-controlled drive

Capacity 2100 3500 lbs, 14 23 passengers


Capacity Passengers Speed Number Available Car Door Shaft Travel
max. of stops entrances (Inside) (Inside) height
max. max. max.

Door
type
A B C D E F (iii)(vii) G H (viii) I (iv) J (vi)
lbs fpm in in in in in ft ft ft ft ft (m) /
(kg) (m/s) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) FPM (m/s)
7-4(vii) 5-9 5-0 12-7
3 3 Front
2100 100 5-9 5/16 4-4 7/8 7-9 3-0 7 (2235) (1755) (1524) (3835)
14 2SSO 48 (14.6) / 100 (.5)
(950) (.5) 3 Front (1761) (1343) (2366) (915) (2134) 7-4(vii) 6-5 5/8 5-0 12-7
3/3
3 Rear (2235) (1972) (1524) (3835)
8-4(vii) 5-9 5-0 12-7
3 3 Front
2500 100 6-9 5/16 4-4 7/8 7-9 2SSO/ 3-6 7 (2540) (1755) (1524) (3835)
17 48 (14.6) / 100 (.5)
(1135) (.5) 3 Front (2066) (1343) (2366) SSCO (1067) (2134) 8-4(vii) 6-5 5/8 5-0 12-7
3/3
3 Rear (2540) (1972) (1524) (3835)
8-4(vii) 6-3 5-0 12-7
3 3 Front
3000 100 6-9 5/16 4-10 7/8 7-9 2SSO/ 3-6 7 (2540) (1905) (1524) (3835)
20 48 (14.6) / 100 (.5)
(1360) (.5) 3 Front (2066) (1495) (2366) SSCO (1067) (2134) 8-4(vii) 6-11 5/8 5-0 12-7
3/3
3 Rear (2540) (2124) (1524) (3835)
8-4(vii) 6-11 1/16 5-0 12-7
3 3 Front
3500 100 6-9 5/16 5-6 7/8 7-9 2SSO/ 3-6 7 (2540) (2110) (1524) (3835)
23 48 (14.6) / 100 (.5)
(1590) (.5) 3 Front (2066) (1699) (2366) SSCO (1067) (2134) 8-4(vii) 7-7 5/8 5-0 12-7
3/3
3 Rear (2540) (2328) (1524) (3835)
A Inside cab width 2SSO 2-speed side F Shaft width
B Inside cab depth opening (i) G Shaft depth
C Inside cab height to SSCO Single speed center H Pit depth
underside of roof. opening I Overhead
[Inside cab height to
finished ceiling is D Door Width
7-5 3/16 (2265).] E Door Height

Notes:
(i) 2SSO doors available with right or left opening.
(ii) Duplex operation available.
(iii) Areas in seismic zone 2 or greater may require up to 3 1/2 more hoistway width. Please contact your Schindler Sales Representative for details and options.
(iv) Clear overhead is defined from the lowest point below any obstruction such as: hoist beam(s), building beams, or roof structure to floor of top landing.
(v) Where permitted by code, no control closet is required. A 3-phase disconnect must be located in both the hoistway overhead and a location in the building outside of the hoistway.
110v disconnect should be located outside of hoistway. Disconnects are not required to be an elevator-dedicated space. Please confirm with local requirements.
(vi) 24 max. floor to floor travel.
(vii) Schindler recommends 8-6 (2500 3500 lbs) and 7-6 (2100 lbs), providing additional hoistway tolerances.
(viii) Please contact your Schindler Sales Representative for options less than 5-0.
(ix) Please contact your Schindler Sales Representative for additional hatch options such as diagonal entrances.
(x) All dimensions are for information only and cannot be used for construction purposes without Schindler confirmation.

Schindler 3100
17
Schindler 3100 MRL Traction Elevator
General Purpose
Standard Speeds: 100 (0.5 m/s)
Openings: 3 front, 3 rear
Travel: Up to 48 (14.6 m)

Hatch plans Hoistways

Front opening (ix)Front/rear opening (ix) Front opening Front/rear opening


two-speed left opening two-speed left opening
(2SSO) (2SSO)
F F

A
A

B B
G G

C E I C E I

D D

Front opening (ix) Front/rear opening (ix)

two-speed right opening two-speed right opening


(2SSO) (2SSO)
F F

A
A

B B
G G

E J E E J

D D

H H
Front opening Front/rear opening
single-speed center opening single-speed center opening
(SSCO) (SSCO)
F F

A
A

B G B G

D D

18 Schindler 3100
Schindler 3100 MRL Traction Elevator
General Purpose
Standard Speeds: 100 (0.5 m/s)
Openings: 3 front, 3 rear
Travel: Up to 48 (14.6 m)

General requirements 15. For ALL power circuits:


Requirements for installation vary by type of equipment selected. These general requirements assist a. If a sprinkler head is located in the hoitway or other disconnect location, any disconnect
you in preparing your building for the installation of Schindler elevators. All designs, clearances, served by that sprinkler head must be NEMA 3 compliant. Sprinklers shall be located at the
construction, workmanship and materials, unless specifically excepted, shall be in accordance with the top and bottom of the hoistway per NFPA 12-2010 requirement 8.15.5.6 (see also 8.15.5.3)
requirements of the latest published ASME A17.1 Code for electric traction elevators plus applicable and A.8.15.5.3).
b. In U.S. jurisdictions ONLY, when a sprinkler head is located in the hoistway, the building
building code and local codes. State or local requirements must be used if more stringent.
shall provide shunt trip activation of a) JH, the main disconnect or b) the feed to the
Items to be provided A complete installation includes the following items not included in the main disconnect, triggered by contacts of the fire recall initiating devices (as defined by
elevator contract: NFPA). These devices, located in the hoistway or other disconnect location, shall provide
1. Clear, plumb hoistway, with variations on a minimum dimension hoistway not to exceed 0 independent disconnection of electrical power to both main and auxiliary power circuits prior
and +1 (25.4 mm) per side at any point. Tolerance may increase to variations not to exceed to sprinkler activation (ASME A17.1-2007/CSA B44-07 rule 2.8.3.3. and/or local code).
1 (25.4 mm) and +1 (25.4 mm) per side at any point when an additional 2 (50.8 mm) is
Control spaces (When specified in lieu of an Inspection and Test Panel, a partial or full
provided on the hoistway width dimension.
body entry space/room shall be provided.)
2. Two-hour fire resistance of hoistway walls or rating to meet applicable local codes. 75 bevel
16. Enclosed and protected control space at top landing adjacent to the hoistway wall closest to the
guards on all projections, recesses or setbacks over 4 (102 mm) except on side used for loading
elevator hoist machine. Two-hour fire rating of control space walls or rating to meet applicable
or unloading. The overhead machinery space temperature at top of hoistway to be maintained
local codes.
between 41 F (5 C) and 104 F (40 C) and < 95% relative humidity, non-condensing.
17. Provide fire-rated, self-closing, self-locking door. Door must be capable of opening 180 degrees
3. Supports for rail brackets at pit, each floor and one or two locations above top floor in the
for access to control space.
overhead (application dependent). Divider beams between hoistways at each floor level and
18. 42 (1067 mm) minimum clear space is required in hallway in front of control space door and top
one or two locations above top floor in the overhead for guide rail bracket supports. Locate per
hoistway entrance for service barriers. Additional hallway width may be required, subject to local
layout. For masonry block hoistway construction, Schindler will provide rail bracket inserts for
building, fire and ADA codes.
installation by others, located per the Schindler final layout drawings. Where inserts are not used,
19. The temperature in front of the control space must be maintained between 32 F (0 C) and
hollow masonry blocks are not acceptable for bracket fastening. Provide 125 mm (5) concrete
104 F (40 C) and less than 95% relative humidity, non-condensing, for proper operation of
belt around hoistway or other acceptable support at each floor, in overhead, and intermediate
equipment.
levels (if required). For max. rail bracket vertical spacing, contact your local sales representative.
20. Disconnects for each elevator must be provided per National Electrical Code (NFPA No. 70) and
4. Supply hoist/safety beam for elevator construction and service work. Beam to run across the width
located inside the elevator control space.
of the elevator shaft. Locate per layout. Hoist beam to be left in place after elevator installation.
5. A temporary work platform is required for installation. It is to be constructed at the top floor Other wiring
of each elevator. It must comply with applicable governing codes and regulations. The platform 21. Suitable copper feeder, ground and branch wiring circuits for signal system and power operated
shall be securely fastened to the building structure. Erection, maintenance, and removal are by door. Feeder and branch wiring circuits for car light and fan.
others. (Reference Schindler drawing TD440.) 22. Telephone outlet provided at the inspection and test panel or in control closet (where applicable).
6. Lighting, light switch and duplex receptacle (GFCI) for each elevator, in the center of hoistway 23. All conduit and wire runs remote from either the control space or hoistways (if required).
pit and in the elevator overhead/machinery space, as indicated by Schindler. The pit light switch 24. Heat, smoke or products of combustion-sensing devices connected to elevator control space
located adjacent to access door. terminals when such devices are required. Sprinklers shall be located at the top and bottom of
7. Recesses, supports, and patching, as required, to accommodate hall button boxes, signal the hoistway per NFPA 13-2010 requirement 8.15.5.6 (see also 8.15.5.3 and A.8.15.5.3). Shunt
fixtures, etc. (if required). trip circuit breaker shall also be installed when sprinklers are present in the hoist way.
8. All barricades outside elevator hoistways or between elevators inside hoistways.
9. Dry pit reinforced to sustain normal vertical forces from rails and buffers. Emergency provisions
10. Drains & sumps in elevator pits, where provided, shall comply with the plumbing code, and shall 25. Elevator Firefighters and other emergency services, depending on height of the building or num-
be provided with a positive means to prevent water, gases and odors from entering the hoistway. ber of landings, per ASME A17.1 Rule 2.27.3 and local codes.
The cover must be secured and level with the pit floor and located to clear elevator equipment. 26. Elevator Firefighters and other emergency services wiring and interconnections to automatic
(Cannot be connected directly to storm drain or sewer.) sprinkler systems or heat and smoke-sensing devices furnished by others.
11. Pit ladders shall be provided where required. 27. When emergency/standby power operation of elevators is required, the Electrical Contractor
should coordinate with Schindler for operation requirements.
Inspection and test panel 28. Provisions for earthquake protection, dictated by building code, are required in various sections
12. A switch placed adjacent to the jamb-mounted inspection and test panel enclosure shall control of the country.
lighting in front of the panel. Minimum lighting to be 200 lux (19 fc).
13. A lockable, 13 1/2 x 15 1/2 x 3 1/2 (minimum), metal cabinet with group-1 key to house required Entrances
electrical schematics and maintenance history documents, shall be wall mounted, adjacent to 29. Hoistway walls must have a fire rating per ASME A17.1 Rule 2.1.1.1.
the disconnect switch, by others, at the top landing. The supplier, location, and mounting of the 30. Furnishing, installing and maintaining the required fire rating of elevator hoistway walls,
cabinet shall be coordinated with Schindler. including the control spaces and also the penetration of fire wall by elevator fixture boxes (if
14. Provide, preferably on the same floor as the elevator inspection and test panel, a lockable panel applicable), is not the responsibility of the elevator contractor.
with a fused disconnect switch or circuit breaker suitable for 3-phase power for the elevator 31. The interface of the elevator wall with the hoistway entrance assembly shall be in strict
control, and a fused disconnect switch or circuit breaker for car lighting for each elevator in a compliance with the elevator contractors requirements.
separate lockable panel adjacent to the 3-phase panel or within the 3 phase panel. The panel(s) 32. Entrance wall and finished floor are not to be constructed until after door frames and sills are
must be accessible to qualified personnel only (NEC NFPA req. 620.51[C]) with a Group 2 key in place.
(ASME A17.1 req. 8.1.3). Alternative locations for the panel(s) can be considered, provided they a. W here front walls are of reinforced concrete, the concrete openings must be minimum 16
are located in accessible areas without obstructions to qualified personnel in compliance with (406 mm) wider [8 (203 mm) on each side] and 8 (203 mm) higher than the clear opening.
NEC NFPA req. 620.51(C). Locate and mark the panels and disconnects with appropriate signage, b. W here drywall or sheet rock construction is used for front walls, it shall be of sufficient
(NEC NFPA 70 req. 620-22 and 620-51, or CSA C22.1-02 sections 38-022 and 38-053). The strength to maintain the doors in true lateral alignment. Drywall contractor to coordinate with
disconnects or circuit breakers may also be located without panels in a Group 2 key-secured the elevator contractor.
room identified and dedicated to elevator apparatus only, and in all cases must be capable Note: A support member must be provided for floor heights greater than 15-0 (4572 mm) to
of being locked in the open position with a lock that cannot be removed from the devices or support entrance header struts.
panel(s). FOR DRIVE IN HOISTWAY CONFIGURATION ONLY: Electrical contractor to supply an c. Door frames are to be anchored to walls and properly grouted in place to maintain legal fire
additional lockable auxiliary non-fused disconnect in the hoistway at the location of the drive rating (masonry construction).
(motor controller), along with wiring from the main disconnect to the auxiliary disconnect (see 33. Filling and grouting around entrance by others.
also NEC NFPA 70 - 2008 req. 620.51[C]{1}). This disconnect must also be lockable in the open 34. Where openings occur, all walls and sill supports must be plumb.
position with a secured lock that cannot be removed from the device.

Schindler 3100
19
Committed to performance,
sustainability and safety

Redefining reliability Sustainability and safety


Schindler is redefining reliability to reduce service At Schindler, we are continually working to
calls and maximize your equipment availability. develop products that are energy-efficient and
Using structured maintenance routines, real-time highly recyclable. We are also committed to
dynamic scheduling, and 24/7 remote monitoring enhancing customer and employee safety. We
on all brands, our highly trained technicians provide see the protection of people and the environment
the service your need when you need it as essential components of our corporate
because life is a moving experience. responsibility and our position as an industry leader.

Schindler Your First Choice


Trusted. Professional. Smart.

Schindler Elevator Corporation


For more information, including location of the
Schindler office nearest you, please visit:

U.S. Headquarters. Morristown, New Jersey


Tel. 973.397.6500
www.us.schindler.com Schindler is a member organization of the
U.S. Green Building Council.

Canada Headquarters. Toronto, Ontario


G17PDF

Tel. 416.332.8280 Schindler has received renewal to ISO 9001 and


www.ca.schindler.com ISO 14001 certificates.
BRN-1027c