A. Data
Pipe Length, L = 10.04 m
Diameter of inner pipe = 0.5 in
Trial 1 Trial 2
Inlet Steam Temperature, () 102 102
Inlet Cooling Water Temperature, () 30 30
Outlet Steam Temperature, () 36 36
Outlet Cooling Water Temperature, () 36 36
Log Mean Temperature Difference, () 8.11 8.11
B. Sample Calculations
a) Heat Transfer area
A 2 Di L
0.0254 m
A 2 0.5 in 10.4 m
1 in
A 0.801 m 2
Data shown in the Table 1 and 2 are the average of the four runs.
c) Mass flow rate of cooling water
Refers to the average volumetric flow rate
m V
0.993342 g 250.18 mL
m
mL s
m 248.5 g
To Tho Tco
To 36 C 36 C
To 0C
when To 0C , the log mean temperature difference will into a mathematical error (ln (0)). Since the principle
behind heat exchangers do not allow equilibrium of temperatures between the two fluids (only at infinite area), there
must be a temperature difference but is very small such that no difference can be observed from temperature gauge.
This very small temperature difference To will be assumed to have a value of To 0.01 C .
Ti Tho Tco
Ti 102 C 30 C
Ti 72 C
0.01C 72C
TLM
ln 0.01C / 72C
Q
U
ATLM
22.43 103 kJ/hr
U
0.801 m 8.11C
2
U 3455 kJ/hr m 2 C