Anda di halaman 1dari 7

PROVISION FAS (INCOTERMS) 300 MW OF THERMOELECTRICAL GENERATION

COMPOSED OF FOUR (4) DUAL TURBOGENERATORS (DIESEL/NATURAL GAS) AERO-


DERIVATIVE COMBUSTION MODEL GE-LM-6000/50 MW ISO AND (1) DUAL
TURBOGENERATOR (DIESEL/NATURAL GAS) AERO-DERIVATIVE COMBUSTION MODEL
GE-LMS100/100 MW ISO.

DESCRIPTIVE

MEMORY

02-08-2010 1 ORIGINAL EMISION A.MENENDEZ B.HERRERA


DATE VERSIN REVISIN CHECK APPROVED
COMPANY: CONSORCIO KCT CUMANA II INTERNACIONAL S.A. PREPARED BY: LUIS FRANCA
DATE: 02-08-2010 REFERENCE: FILE N: CC-152-001
PROVISION FAS (INCOTERMS) 300 MW OF THERMOELECTRICAL GENERATION
COMPOSED OF FOUR (4) DUAL TURBOGENERATORS (DIESEL/NATURAL GAS) AERO-
DERIVATIVE COMBUSTION MODEL GE-LM-6000/50 MW ISO AND (1) DUAL
TURBOGENERATOR (DIESEL/NATURAL GAS) AERO-DERIVATIVE COMBUSTION
MODEL GE-LMS100/100 MW ISO.

1.- OBJECTIVE

The object of this document is to describe the systems and equipment that are part of the
300 MW Thermoelectrical Generation to be supplied in short term.

2.- SCOPE OF THE OFFER

This offer includes the supply of the following equipment, FAS port of shipment:

One (01) dual fuel (Natural Gas / Diesel) Turbine Generator Set aero-derivative
Model GE-LM-6000/ 50 MW - ISO, 13,8/115 kV, located in Abilene, Texas USA. FAS
- Houston, Texas USA.

One (01) dual fuel (Natural Gas / Diesel) Turbine Generator Set aero-derivative
Model GE-LM-6000/ 50 MW - ISO, 13,8/115 kV, in process of manufacture in GE,
Hungary. FAS Constanta, Rumany.

One (01) dual fuel (Natural Gas / Diesel) Turbine Generator Set aero-derivative
Model GE-LMS100/ 100 MW - ISO, in process of manufacture in GE, Houston,
Texas USA. FAS - Houston, Texas USA.

Two (02) dual fuel (Natural Gas / Diesel) Turbine Generator Set aero-derivative
Model GE-LM-6000 / 50 MW - ISO, 13,8/115 kV, in process of manufacture in GE,
Houston, Texas USA. FAS - Houston, Texas USA.

3.- DESIGN CRITERIA

For the development of the proposal the following criteria are considered:

1. Necessity to contribute to the Generation of the National Electrical System with 300
MW in the shortest possible time with the intention of taking care of the increasing
and existing demand in the Bolivarian Republic of Venezuela.

2. To diminish the implementation time of the projects through the use of existing
equipment that may be readily available or to be supplied in 2010.

3. It includes the supply of step-up transformers.

2 de 7
PROVISION FAS (INCOTERMS) 300 MW OF THERMOELECTRICAL GENERATION
COMPOSED OF FOUR (4) DUAL TURBOGENERATORS (DIESEL/NATURAL GAS) AERO-
DERIVATIVE COMBUSTION MODEL GE-LM-6000/50 MW ISO AND (1) DUAL
TURBOGENERATOR (DIESEL/NATURAL GAS) AERO-DERIVATIVE COMBUSTION
MODEL GE-LMS100/100 MW ISO.

4.- SCOPE OF SUPPLY

4.1 GENERAL ELECTRIC EQUIPMENTS - NEW.

The supply of the Turbo generators model LM 6000 PC Sprint, 50 MW ISO, as well as
model LMS100, 100 MW ISO, includes the following equipment:

4.1.2 PACKAGE OF THE TURBINE GENERATOR SET LM 6000:

Turbine Model LM 6000 PC Sprint as described in Annex No. 1 (GE LM 6000 Gas
Turbine Generator Set, Scope of Supply).
Generator operating at 13,8 kV.-
Turbine/Generator enclosure
Turbine/Generator Base plate
Air inlet sytem
Turbine Exhaust
Fuel System
Lube Oil System
Electro Hydraulic Star System
Fire Protection System
Digital Control System
Battery System
Generator Protective Relay
Soak Wash System
Component Testing and Package Test
Generator Protective Relays
Drawings, Data and Manual
Training
Power System Stabilizer (PSS)
Dual Fuel System
Water injection for NOx Control
Remote Monitoring and Diagnostic Service
Power Control Module
Combustion Turbine Generator (CTG) Motor Control Center
Intercooler Water Pump Skid Motor Control Center
CTG Foundation Anchoring System

3 de 7
PROVISION FAS (INCOTERMS) 300 MW OF THERMOELECTRICAL GENERATION
COMPOSED OF FOUR (4) DUAL TURBOGENERATORS (DIESEL/NATURAL GAS) AERO-
DERIVATIVE COMBUSTION MODEL GE-LM-6000/50 MW ISO AND (1) DUAL
TURBOGENERATOR (DIESEL/NATURAL GAS) AERO-DERIVATIVE COMBUSTION
MODEL GE-LMS100/100 MW ISO.

Air Cooled Generator 13,8 kV / 60 Hz.


Modules of Auxiliary Services (Lubrication, Fire Protection System, Fuel)
Ducts & Filters for combustion Air.

4.1.3 OTHER EQUIPMENT PROVIDED WITH LM 6000:

Exhaust System (Chimney).


Step-up Power Transformer 13,8 / 115 kV 70/90 MVA 60 Hz
Auxiliary transformer 13,8 KV / 4,16 kV - 5 MVA, 60 Hz.
Auxiliary transformer 750 KVA 4,16 kV/ 480 V.
Bus Bar ducts.
Power Circuit Breaker - Generator. (Synchronism switch in 13,8 kV).
.
4.2.1 PACKAGE OF THE TURBINE GENERATOR SET LMS 100:

Turbine Model LMS 100 Sprint as described in Annex No. 2 (GE LMS 100 Gas Turbine
Generator Set , Scope of Supply).
Generator operating at 13,8 kV.
Turbine/Generator enclosure
Turbine/Generator Base plate
Air inlet sytem
Intercooler
Turbine Exhaust
Fuel System
Lube Oil System
Electro Hydraulic Star System
Fire Protection System
Digital Control System
Battery System
Generator Protective Relay
On/Off Line Cleaning and Soak Wash System
Component Testing and Package Test
Generator Protective Relays
Drawings, Data and Manual
Training
Power System Stabilizer (PSS)
Dual Fuel System
Water injection for NOx Control
Remote Monitoring and Diagnostic Service
Power Control Module
Combustion Turbine Generator (CTG) Motor Control Center

4 de 7
PROVISION FAS (INCOTERMS) 300 MW OF THERMOELECTRICAL GENERATION
COMPOSED OF FOUR (4) DUAL TURBOGENERATORS (DIESEL/NATURAL GAS) AERO-
DERIVATIVE COMBUSTION MODEL GE-LM-6000/50 MW ISO AND (1) DUAL
TURBOGENERATOR (DIESEL/NATURAL GAS) AERO-DERIVATIVE COMBUSTION
MODEL GE-LMS100/100 MW ISO.

Intercooler Water Pump Skid Motor Control Center


CTG Foundation Anchoring System
Air Cooled Generator 13.8 kV / 60 Hz.
Modules of Auxiliary Services (Lubrication, Fire Protection System, Fuel)
Ducts & Filters for combustion Air.

4.2.2 OTHER EQUIPMENT PROVIDED LMS 100:

Exhaust System (Chimney).


Step-up Power Transformer 13,8/230 kV 125/150 MVA 60 Hz.
Auxiliary transformer 13.8 kV / 4,16 kV, 10 MVA, 60 HZ.
Auxiliary transformer 1500 KVA - 4,16 kV/ 480 V.
Bus Bar ducts.
Power Circuit Breaker - Generator.
Chilled water system for turbine intercooler

5.0 SPARE PARTS

Our offer include the spare parts necessary for one year of operation of the equipment
being supplied as shown in Annex No. 3.

6.0 LIMITS OF SUPPLY/INTERFACES

6.1 LM 6000 TURBINE GENERATOR SET

The scope of supply ends at the following interface point boundaries:

ELECTRICAL:

At the high voltage connection (115 kV) of the main (step-up ) transformers, at the bushing
point.

MECHANICAL:
At the following connection points of the turbine auxiliary equipment:

Fuel Gas: natural gas to be supplied by others at the base plate of the turbine for
connection to the fuel-metering valve of the turbine fuel gas system. Fuel gas must
be supplied by others at a pressure of 675 psig +/- 20 psig and meet the
requirements of GE specification MID-TD-0000-6.

5 de 7
PROVISION FAS (INCOTERMS) 300 MW OF THERMOELECTRICAL GENERATION
COMPOSED OF FOUR (4) DUAL TURBOGENERATORS (DIESEL/NATURAL GAS) AERO-
DERIVATIVE COMBUSTION MODEL GE-LM-6000/50 MW ISO AND (1) DUAL
TURBOGENERATOR (DIESEL/NATURAL GAS) AERO-DERIVATIVE COMBUSTION
MODEL GE-LMS100/100 MW ISO.

Cooling Water: to be provided by others for the cooling of the turbine lube oil
coolers located in the auxiliary equipment module of the turbine and in the main skid
base plate.

Demineralized water: to be provided by others for the following uses at the


following locations:

Turbine Cleaning System: water to be provided at the auxiliary skid connections


of the turbine. Water must be supplied at 15-65 psig and meet the requirements
of GE specification MID-TD-0000-4.

Sprint Power Augmentation: water to be supplied at a flow rate of 5 to 30 gpm at


the connections in the turbine. Water must meet the requirements of GE
specification MID-TD-0000-3.

NOx Control: water must be supplied at a flow rate of 55 gpm for fuel gas and
78 gpm for liquid fuel at a pressure of 5-25 psig. The water must be supplied at
the water injection module of the turbine. Water must meet GE specification
MID- TD-0000-3.

Liquid Fuel: liquid fuel to be supplied by others at the connection of the fuel boost
module at 20-50 psig and at a minimum of 11 C above the wax point temperature.
Fuel must be clean and meet GE specification MD-TD-0000-2.

Compressed Air: compressed air must be supplied 80 to 120 psig by others at the
turbine.

6.2 LMS 100 TURBINE GENERATOR SET

The scope of supply ends at the following interface point boundaries:

ELECTRICAL:

At the high voltage connection (230 kV) of the main (step-up ) transformers, at the bushing
point.

MECHANICAL:

At the following connection points of the turbine auxiliary equipment :

Fuel Gas: natural gas to be supplied by others at the base plate of the turbine for
connection to the fuel-metering valve of the turbine fuel gas system. Fuel gas must
be supplied at a pressure of 830 to 940 psig and meet the requirements of GE
specification MID-TD-0000-1.

6 de 7
PROVISION FAS (INCOTERMS) 300 MW OF THERMOELECTRICAL GENERATION
COMPOSED OF FOUR (4) DUAL TURBOGENERATORS (DIESEL/NATURAL GAS) AERO-
DERIVATIVE COMBUSTION MODEL GE-LM-6000/50 MW ISO AND (1) DUAL
TURBOGENERATOR (DIESEL/NATURAL GAS) AERO-DERIVATIVE COMBUSTION
MODEL GE-LMS100/100 MW ISO.

Cooling Water: to be provided by others for the cooling of the turbine lube oil
coolers located in the auxiliary equipment module of the turbine and in the main skid
base plate.

Demineralized water: to be provided by others for the following uses at the


following locations:

Turbine Cleaning System: water to be provided at the auxiliary skid connections


of the turbine. Water must be supplied at 15-65 psig and meet the requirements
of GE specification MID-TD-0000-4.

NOx Control: water must be supplied at a flow rate of 55 gpm for fuel gas and
78 gpm for liquid fuel at a pressure of 5-25 psig. The water must be supplied at
the water injection module of the turbine. Water must meet GE specification
MID- TD-0000-3.

Liquid Fuel: liquid fuel to be supplied by others at the connection of the fuel boost
module at 45 to 115 psig and at a minimum of 11 C above the wax point
temperature. Fuel must be clean, filtered and meet GE specification MD-TD-0000-2.

Compressed Air: compressed air must be supplied 80 to 120 psig by others at the
turbine auxiliary skid.

7 de 7

Anda mungkin juga menyukai