PROJECT:

= H-TYPE
(S+7)BLDG
FOR H-TYPE (S+7) BLDG FOR LAUKIK DEVELOPERS
LAUKIK AT RAMCHANDRANAGAR-KALYAN
DEVELOP LOADING ANALYSIS
ERS
Description Thk Density Loading
Sr No
(mm) (T/cum) (T/sqm)
1 Floor Slab
1.1 Self Weight 125 2.5 0.313
1.2 Ceiling Plaster 12 2.08 0.025
1.3 Tiling 23 2.2 0.051
1.4 CM finish 21 2.32 0.049
1.5 Live Load 0.2
Total 0.637
Say 0.650
2 Roof Slab
2.1 Self Weight 125 2.5 0.313
2.2 Ceiling Plaster 12 2.08 0.025
2.3 CM finish 25 2.08 0.052
2.4 Brick Bat Coba 100 1.95 0.195
2.5 Live Load 0.15
Total 0.734
Say 0.750
3 Common Corridor / Balconies
3.1 Self Weight 125 2.5 0.313
3.2 Ceiling Plaster 12 2.08 0.025
3.3 CM finish 25 2.08 0.052
3.4 Tiling 23 2.2 0.051
3.5 Live Load 0.3
Total 0.740
Say 0.750
5 WC Slab
sunk 600
5.1 Self Weight 100 2.5 0.250
5.2 Ceiling plaster 12 2.08 0.025
5.2 WP Plaster 25 2.08 0.052
5.3 Brick Bat Coba 550 1.95 1.073
5.4 CM finish 25 2.08 0.052
5.5 Tiling 25 2.2 0.055
5.6 Live Load 0.2
Total 1.706
Say 1.710
6 Bath Slab
sunk 250
6.1 Self Weight 100 2.5 0.250
6.2 Ceiling plaster 12 2.08 0.025
6.3 WP Plaster 25 2.08 0.052
6.4 Brick Bat Coba 200 1.95 0.390
6.5 CM finish 25 2.08 0.052
6.6 Tiling 25 2.2 0.055
6.7 Live Load 0.2
Total 1.024
Say 1.030
7 Stair Case
Tread 250 mm
Rise 161.66 mm
Angle of Flight 36
7.1 Self Weight 150 2.5 0.464
7.2 Self wt. Of Steps 0.202
7.3 Ceiling plaster 12 2.08 0.025
7.4 CM finish 25 2.08 0.052
7.5 Tiling 25 2.2 0.055
7.6 Live Load 0.300
Total 1.098
Say 1.200
D:\NJG\B-TYPE\MCROOM\LOADING ANALYSIS.XLS 4/24/2003 11:42 A.M

LOADING ANALYSIS FOR M/C ROOM & WATER TANK FOR B -TYPE

M/C ROOM
THK DENSITY

1 SELF WT 0.2 25 5 KN/M2


2 LIVE LOAD - - 10 KN/M2
3 CEILING PLASTER 0.012 20.8 0.2496 KN/M2
4 C.M. BEDDING 0.025 20.8 0.52 KN/M2
5 I.P.S FLOORING 0.025 20.8 0.52 KN/M2
TOTAL 16.29 SAY 16.5 KN/M2

WATER TANK

1 SELF WT 0.2 25 5 KN/M2


2 LIVE LOAD 3.34 10 33.4 KN/M2
3 CEILING PLASTER 0.012 20.8 0.2496 KN/M2
4 C.M. BEDDING 0.025 20.8 0.52 KN/M2
5 WATER PRROFING 0.05 20.8 1.04 KN/M2
TOTAL 40.21 SAY 40.3 KN/M2

ROOF SLAB (INACCESSIBLE)


THK DENSITY

1 SELF WT 0.125 25 3.125 KN/M2


2 LIVE LOAD - - 0.75 KN/M2
3 CEILING PLASTER 0.012 20.8 0.2496 KN/M2
4 B.B COBA 0.1 19.5 1.95 KN/M2
5 I.P.S FLOORING 0.025 20.8 0.52 KN/M2
TOTAL 6.59 SAY 7.0 KN/M2

ROOF BEAMS
AT EXTERNAL FACE WIDTH DEPTH DENSITY UDL

1 SELF WT 0.15 0.75 25 2.8125 KN/M


2 WALL LOAD 0.1 0.95 25 2.375 KN/M

TOTAL 5.19 SAY 5.3 KN/M

ROOF BEAMS
AT INTERNAL FACE WIDTH DEPTH DENSITY UDL

1 SELF WT 0.15 0.45 25 1.6875 KN/M


2 WALL LOAD 0 0.95 25 0 KN/M
TOTAL 1.69 SAY 2.5 KN/M

SOFFIT BEAMS
FOR WALL BEAM WIDTH DEPTH DENSITY UDL

1 SELF WT 0.15 3.615 25 13.55625 KN/M

TOTAL 13.556 SAY 13.6 KN/M

SOFFIT BEAMS
FOR WALL+ BEAM WIDTH DEPTH DENSITY UDL

1 SELF 0.15 0.6 25 2.25 KN/M


2 WALL LOAD 0.15 2.94 7.8 3.4398
3 PLASTER 0.032 3.54 20.8 2.356
TOTAL 8.046 SAY 8.1KN/M

SOFFIT BEAMS
FOR WALL+ BEAM WIDTH DEPTH DENSITY UDL

1 SELF 0.15 0.6 25 2.25 KN/M


2 WALL LOAD 0.15 4.4 7.8 5.148
3 PLASTER 0.032 4.4 20.8 2.929
TOTAL 10.327 SAY 10.5KN/M

SOFFIT BEAMS
FOR WALL+ BEAM WIDTH DEPTH DENSITY UDL

1 SELF 0.15 0.2 25 0.75 KN/M


2 WALL LOAD 0.15 3.34 25 12.525

TOTAL 13.275 SAY 13.3KN/M


13.6 KN/M
PROJEC := H-TYPE (S+7) BLDG FOR LAUKIK DEVELOPERS
AT RAMCHANDRANAGAR-KALYAN

Floor to Floor Height 2.9 m


Plinth Height 0.15 m
Floor Beam Depth 0.6 m
Plinth Beam Depth 0.6 m
Ht Of Beam below Plinth 0.2 m

LOADING ANALYSIS

Description Width Depth Density Loading


Sr No
(mm) (mm) (T/cum) (T/m)
1 External Wall @Floor
1.1 Self Weight of beam 230 600 2.5 0.345
1.2 Wt of Brick Wall 150 2300 1.95 0.673
1.3 Plaster 36 2900 2.08 0.217
Total 1.235
Say 1.250
2 Internal Wall @Floor
2.1 Self Weight of beam 230 600 2.5 0.345
2.2 Wt of Brick Wall 150 2300 1.95 0.673
2.3 Plaster 24 2900 2.08 0.145
Total 1.163
Say 1.250
3 Parapet Wall @ Roof
3.1 Self Weight of beam 230 600 2.5 0.345
3.2 Wt of Brick Wall 150 1150 1.95 0.336
3.3 Wt of Coping 150 50 2.08 0.016
3.4 Plaster 36 1800 2.08 0.135
Total 0.832
Say 0.850
4 External Wall / Internal Wall @ Plinth (Stilt Portion)
4.1 Self Weight of beam 230 600 2.5 0.345
4.2 Wt of Brick Wall 150 0 1.95 0.000
4.3 Plaster 36 0 2.08 0.000
Total 0.345
Say 0.345
7 OF11

HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. SH. NO.


Subject : EARTH QUAKE COEFFICICENT CALCULATION STANDARD EXCEL DESIGN REV. R0
Details : Horizontal Seismic coefficient Calculation DATE 13-02-06
as Per IS 1893 -2000 BY NITESH
REF

PROJECT :

CALCULATION OF DESIGN HORIZONTAL SEISMIC COEFFICIENT AS PER IS - 1893-2002

PARAMETERS:=
Type of Soil Site 2
( 1- Hard Soil , 2 - Medium Soil , 3 - Soft Soil )

Type of Structure 3
( 1- RC Str , 2 - Steel Str , 3 - All other )

Height of Structure 6.6 m


(2.0 + 4.6 = 6.6 m )

Type of Brick Infill Panel with

Base Dimension of structure along X-direction 24 m

Base Dimension of structure along Z-direction 18 m


EXPRESSION :=
Ah = Z x I x Sa
2x Rxg

Where,
Ah Design horizonal Seismic Coefficent

Z Zone Factor 0.10

I Importance Factor 1.5

R Response Reduction Factor 3.0

Sa/g Average Resspose Accleration Coefficient


for rock or soil sites

For Rocky or Hard Soil Sites ( SS = 1)


X-dir Z-dir
1 + 15 T 0.00 <= T <= 0.10
Sa/g 2.50 0.10 <= T <= 0.40
1.00 / T 0.4 <= T <= 4.00
For Medium Soil Sites ( SS =2 )
1 + 15 T 0.00 <= T <= 0.10
Sa/g 2.50 2.5 2.5 0.10 <= T <= 0.40
8 OF11

HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. SH. NO.


Subject : EARTH QUAKE COEFFICICENT CALCULATION STANDARD EXCEL DESIGN REV. R0
Details : Horizontal Seismic coefficient Calculation DATE 13-02-06
as Per IS 1893 -2000 BY NITESH
REF

1.36 / T 0.4 <= T <= 4.00


For Soft Soil Sites ( SS = 3)
1 + 15 T 0.00 <= T <= 0.10
Sa/g 2.50 0.10 <= T <= 0.40
1.67 / T 0.4 <= T <= 4.00

Where T= approximate fundamental natural period of vibration ( Ta ) in Sec

FOR MOMENT RESISTING FRAME BUILDING WITHOUT BRICK INFILL PANELS

for X & Z- direction

for RC frame building for Steel frame building

Ta= 0.075 h 0.75 Ta= 0.085 h 0.75


sec sec
where,
h= Height of building in m

FOR ALL OTHER BUILDING INCLUDING MOMENT RESISTING FRAME BUILDING WITH BRICK INFILL PANELS

Ta= 0.09h / sqrt ( d )


where,
h= Height of Building in m
d= Base dimension of the building at the plinth level in m,
along the considered direction of the lateral force
for X- direction for Z- direction
Tax= 0.121 sec Taz= 0.140 sec

FOR X- DIRECTION FOR Z- DIRECTION

Tax= 0.121 sec Taz= 0.140 sec


sa/g= 2.5 sa/g= 2.5

Ahx = Z x I x Sa Ahz = Z x I x Sa
2x Rxg 2x Rxg

Design horizonal Seismic Coefficent are,


Ahx = 0.0625 Ahz = 0.0625
6.25 % 6.25 %
9 OF11

HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. SH. NO.


Subject : EARTH QUAKE COEFFICICENT CALCULATION STANDARD EXCEL DESIGN REV. R0
Details : Horizontal Seismic coefficient Calculation DATE 13-02-06
as Per IS 1893 -2000 BY NITESH
REF
10OF11

HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. SH. NO.


Subject : WIND PRESSURE CALCULATION STANDARD EXCEL DESIGN REV. R0
Details : Wind Pressure Calculation as Per DATE 18-12-17
IS 875 ( Part 3 )-1987 BY NITESH
REF

WIND PRESSURE CALCULATION ( AS PER IS - 875-PART-III )-1987

PARAMETERS:=

Pz = 0.6 x VZ2

Vz = Vb x K1 x K2 x K3

Where,
Pz Design Wind Pressure in N/m2 at height z

Vz Design Wind Velocity in m / sec at height z

Vb Basic Wind Speed in m/sec VISAKHAPATNAM 50 m/sec

Design Life of Structure / Building = 5 Years

K1 Probablity Factor( Risk Coefficient) 0.70

K2 Terrain Height and Structure Size Factor


Height of Structure = 10 m
Category 2 Class A #VALUE!

K3 Topography Factor 1.0

VZ = Vb x K1 x K2 x K3

VZ = #VALUE! m/sec

Pz = 0.6 x VZ2

Pz = #VALUE! N/m2

Pz = #VALUE! Kg/m2

Pz = #VALUE! T/m2

ADOPT DESIGN WIND PRESSURE = #VALUE! T/m2


11OF11