DATASHEET FOR STEPDOWN TRANSFORMER
TITLE

ATTOCK PETROLEUM LIMITED DOCUMENT NO. 2548-DSE-005 REV-0

GENERAL
1 Equipment Name As per Vendor 6 Location
2 Tag Number TF-001 7 Manufacturer
3 Number Required 1 8 Model No.
4 Major Dimensions (L X W X H) mm VTS 9 Weight (Kg)
5 Performance Standard As per Specification 10

ENVIRONMENTAL DATA
11 Maximum Temperature 50 oC 17 Area Classification
12 Minimum Temperature 0 C
o
18 Zone
13 Ambient Temperature 35 oC 19 Group
14 Maximum Humidity 90% 20 Location
15 Altitude Above Sea Level 550 Meters 21 Temperature Class
16 Maximum Sound Level at 1 m 85 dB

TRANSFORMER CHARACTERSTICS
22 Transformer Capacity 1250 kVA Effeciency at 50 %Load
32
23 Primary No-Load Voltage 11 kV 75 oC * %
24 Secondary No-Load Voltage 0.4 kV 33 Impedance voltage (rated current, frequency
25 No. of Phase 3 Regulation at Rated Power
34
26 Frequency 50 Hz at 75 oC
27 Vector Group Dyn11 35 BIL Level
28 No Load Loss(at rated voltage frequency) VTS kW 0% 36 System Fault Level
29 Load Loss(at rated voltage, current and frequency at 55 oC) VTS kW 0%
30 Cooler Loss(at rated voltage, current and frequency at 55 oC) VTS kW 0%
31 X / R Ratio VTS

OTHER OPERATIONAL AND PHYSICAL CHARACTERSTICS


ANAN ANAF AN AF 40 Conservator Required
37 Cooling Method ONAN ONAF OFAN ODAN 41 Oil Type
OFAF ODAF Max. Temp Rise of top oil at 100% full load
42
38 Duty Continuous Stand-by Intermittent (Measured by Thermometer)
39 Finishing Paint type Epoxy paint 43 Paint Shade

WINDINGS OPERATING PARAMETERS


Low Voltage Winding/Secondary High Voltage Winding/P
44 Winding Material Copper 53 Winding Material
45 Low Voltage Winding Voltage 0.4 kV 54 High Voltage Winding Voltage
46 Voltage operating range 5 % 55 Voltage operating range
47 Winding Connection Star Delta 56 Winding Connection
Secondary Solid Ungrounded NER (Low Resistance) Primary System Solid Ungrounded
48 57
System Earthing NER (High Resistance) Earthing Transformer Earthing NER (High Resistance)

Page 1 of 4
FUEL FARM FACILITY AT ISLAMABAD INTERNATIONAL
AIRPORT

DOCUMENT
DATASHEET FOR STEPDOWN TRANSFORMER
TITLE

ATTOCK PETROLEUM LIMITED DOCUMENT NO. 2548-DSE-005 REV-0

NER (High Resistance) Earthing Transformer NER (High Resistance)


49 Secondary terminal box withstand capacity VTS kA for 1 sec 58 Primary terminal box withstand capacity
50 Type of Insulation of Winding Cellulose Based/Class A 59 Type of Insulation of Winding
51 Winding Resistance VTS 60 Winding Resistance
52 Winding temperature Rise 65 C
o 61 Winding temperature Rise

TERMINATIONS
62 LV Termination Cable 65 HV Termination
63 Neutral Termination Cable 66 Star Point Termination
64 Disconnecting Chambers VTS 67 Jacking Lugs

TAP CHANGERS
68 Tap Changer Required Not Required 69 HV side Tap Changers as 2.5%, 5% and -7.5

SURGE ARRESTER
Low Voltage Side High Voltage Sid
70 Surge Arresters Required Not Required 71 Surge Arresters Required

ACCESSORIES
72 Oil Temperature Indication Required Not Required 75 Winding Temperature Indication
73 Oil Level Indication Required Not Required 76 Pressure Relief Vent
74 Lower Oil Sample Valve Required Not Required 77 Upper Fill/Filter Valve
78 Buchholz Relay

TRANSFORMER ARRANGEMENTS
Dry
79 Transformer Tank Type Sealed Conservator
Type
80 Mounting Arrnagements Pad Mount
81 Oil Required

STANDARDS AND CERTIFICATION AUTHORITES


82 As per Specifications

Notes
VTS Vendor to Specify
** On Request Only (Not Required in this Project)
*** Manufacturer to Provide Complete Specification and applicable standards for this type of arrangements

12/19/2015 0 ISSUED FOR REVIEW HUN


Date Rev Description Prep.

Page 2 of 4
GENERAL
Transformer Area
Siemens / PEL
As per Vendor
VTS

IRONMENTAL DATA
Hazardous Non-Hazardous
1 2
IIA IIB IIC
Indoor Outdoor
-

RMER CHARACTERSTICS
75% Load 100 % Load
* % * %
Impedance voltage (rated current, frequency at 75 oC) * %
0.8 PF 1.0 PF
* % * %
75 kV
30 kA

L AND PHYSICAL CHARACTERSTICS


Required Not-Required
Mineral Oil
Max. Temp Rise of top oil at 100% full load
55 oC
(Measured by Thermometer)
RAL 7032

OPERATING PARAMETERS
High Voltage Winding/Primary
Copper
11 kV
5 %
Star Delta
NER (Low
Ungrounded Resistance)
NER (High Resistance) Earthing Transformer

Page 3 of 4
NER (High Resistance) Earthing Transformer
VTS kA for 1 sec
Cellulose Based/Class A
VTS
65 C
o

TERMINATIONS
Cable
Cable
Copper

TAP CHANGERS
HV side Tap Changers as 2.5%, 5% and -7.5%

URGE ARRESTER
High Voltage Side
Required Not Required

ACCESSORIES
Required Not Required
Required Not Required
Required Not Required
Required Not Required

ORMER ARRANGEMENTS
Pad Mount Other
* Litres

D CERTIFICATION AUTHORITES

on and applicable standards for this type of arrangements

IA SMS
Chk. Appr.

Page 4 of 4

Anda mungkin juga menyukai