2 Power turbine
Two-stage uncooled free power turbine
1 offers nominal shaft speed up to
2 6,500 rpm. For mechanical drive, it may
operate at 50 to 105 percent of the
3 nominal speed. The Power Turbine can
be matched for optimal performance
at different ambient conditions.
3 Compressor
11-stage axial-flow transonic compressor
incorporating the latest aerodynamics,
with variable guide vanes for robust op-
erability and optimized performance over
a wide range of operating conditions.
Easy to maintain, reliable, and robust twin-shaft design
for mechanical drive and power generation
siemens.com/gasturbines
SGT5-8000H 400 MW
50 Hz
SGT5-4000F 307 MW
SGT5-2000E 187 MW
SGT6-8000H 296 MW
60 Hz
SGT6-5000F 242 MW
SGT6-2000E 117 MW
Industrial Trent 60 53 to 66/54 to 62 MW
SGT-800 48 to 54 MW
SGT-750 38/39 MW
SGT-700 33/34 MW
50 or 60 Hz
Industrial RB211 27 to 32/28 to 34 MW
SGT-600 24/25 MW
SGT-500 19/19 MW
SGT-400 13 to 14 MW/13 to 15 MW
SGT-300 8/8 to 9 MW
SGT-200 7/8 MW
SGT-100 5/6 MW
Industrial 501-K 4 to 6 MW
Power generation package using the identical driver Oil and gas mechanical drive package – Gas turbines from 4 to 400 MW
as the mechanical drive package very high availability
Physical dimensions
Power generation package Mechanical drive package
Approx. weight 169,000 kg (372,581 lb) 63,000 kg (138,891 lb)
Length 18.8 m (61.7 ft) 11.7 m (38.4 ft)
Width 4.6 m (15.0 ft) 4.0 m (13.1 ft)
Height 4.0 m (13.1 ft) 4.0 m (13.1 ft)
10.8
34 32 mance features which may not always specifi
Heat rate [MJ/kWh]
10.6 9.8
32 cally reflect those described, or which may
Power [MW]
10.4 28 10.2
30 10.6 undergo modification in the course of further
10.2 Heat rate
10.0 24 [MJ/kWh] development of the products. The requested
28
9.8 11.0 performance features are binding only when
26 20
9.6 they are expressly agreed upon in the con
24 12.0 cluded contract.
9.4 16
22 9.2
20 9.0 12 Note: All combined cycle performance is based
–30 –20 –10 0 10 20 30 40 50 60 3,250 4,250 5,250 6,250 on dual pressure, no reheat. Above dimensions
Ambient temperature [° C] Power turbine speed [rpm] exclude inlet filter housing and exhaust stack.
For power generation, AC generator is included.
For mechanical drive, driven equipment is
Above performances at ISO conditions, gaseous fuel excluded.