Anda di halaman 1dari 18

Nokia Siemens Networks GSM/EDGE BSS, rel.

RG10(BSS), operating documentation, issue 1

EG - GSM Timer and BSC


Parameter Handling

DN9813203 # Nokia Siemens Networks 1 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted in
any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity, or
performance of the mentioned hardware or software products are given “as is” and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS
DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,
DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT
NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA, THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE
INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of
Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners,
and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2009. All rights reserved.

2 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
Contents

Contents

Contents 3

List of tables 4

List of figures 5

Summary of changes 7

EG - GSM TIMER AND BSC PARAMETER HANDLING 9

EGO OUTPUT TIMERS/PARAMETERS 11

EGT MODIFY TIMER 13

EGP MODIFY PARAMETER 17

DN9813203 # Nokia Siemens Networks 3 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

List of tables

4 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
List of figures

List of figures

DN9813203 # Nokia Siemens Networks 5 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

6 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
Summary of changes

Summary of changes

Changes between document issues are cumulative. Therefore, the latest


document issue contains all changes made to previous issues.

Changes made between issues 10-0 and 9-0

EGO OUTPUT TIMERS/PARAMETERS


Added the timer T3111_DTM to the execution
printout.

Changes made between issues 9-0 and 8-1

EGO OUTPUT TIMERS/PARAMETERS


The execution printout was updated.

Changes made between issues 8-1 and 8-0

EGT MODIFY TIMER


Changed the explanation of 'time unit' as timers
T3168 and T3192 have different ranges of values.

DN9813203 # Nokia Siemens Networks 7 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

8 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
EG - GSM TIMER AND BSC PARAMETER HANDLING

EG - GSM TIMER AND BSC PARAMETER


HANDLING
With the commands of this command group you handle GSM timers and
BSC parameters.

Menu of the command group:

GSM TIMER AND BSC PARAMETER HANDLING COMMANDS

? ..... DISPLAY MENU


O: ..... OUTPUT TIMERS/PARAMETERS
T: ..... MODIFY TIMER
P: ..... MODIFY PARAMETER
Z; ..... RETURN TO MAIN LEVEL

DN9813203 # Nokia Siemens Networks 9 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

10 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
EGO OUTPUT TIMERS/PARAMETERS

EGO OUTPUT TIMERS/PARAMETERS


Function With the command EGO you print out the name, value, preset value, and
type of timers and parameters.

Parameters output category;

Syntax EGO: [ <output category> | <all> def ];

Parameter output category


explanations
The parameter can have the following values:

TIM Displays timers.


PAR Displays parameters.
ALL Displays all timers and parameters.

The default value is all timers and parameters.

Examples 1. Display all timers and parameters.

ZEGO; or ZEGO:ALL;
2. Display timers.
ZEGO:TIM;

Execution The execution printout for example 2 is the following:


printouts

PRESET
PARAMETER VALUE VALUE MODIFIABLE
-------------------------------- —--------------------------------
T4 60.00 S 60.00 S YES
T7 20.00 S 20.00 S YES
T8 12.00 S 12.00 S YES
T10 8.00 S 8.00 S YES
T13 15.00 S 15.00 S YES

DN9813203 # Nokia Siemens Networks 11 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

T17 4.00 S 4.00 S YES


T18 12.00 S 12.00 S YES
T3101 3.00 S 3.00 S YES
T3103 6.00 S 6.00 S YES
T3105_D 0.28 S 0.28 S NO
T3105_F 0.10 S 0.10 S NO
T3107 6.00 S 6.00 S YES
T3109 12.00 S 12.00 S YES
T3111 0.50 S 0.50 S NO
T3111_DTM 0.30 S 0.30 S YES
T3121 12.00 S 12.00 S YES
T3122 6.00 S 6.00 S YES
T3168 1.00 S 1.00 S YES
T3192 0.50 S 0.50 S YES
T9101 10.00 S 10.00 S NO
T9103 2.00 S 2.00 S NO
T9104 15.00 S 15.00 S YES
T9105 10.00 S 10.00 S YES
T9108 2.00 S 2.00 S NO
T9113 13.00 S 13.00 S YES
TBBI 15.00 S 15.00 S YES

COMMAND EXECUTED

The values of all timers are displayed in seconds.

Semantic error If an error occurs, the general semantic error messages of MML
messages commands are printed out.

Execution error
messages

/*** READING PARAMETER FILE FAILED ***/

The MML is unable to read the parameter file.

12 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
EGT MODIFY TIMER

EGT MODIFY TIMER


Function With the command EGT you modify the value of the timer.

Parameters timer name: time unit, timer value;

Syntax EGT: ( <timer name> ) :


[ <time unit> | 1 def] ,
( <timer value> ) ;

Parameter timer name


explanations
The parameter indicates the timer which is to be modified.

The timer names comprise 1-10 characters. The names of timers are listed
in the guidance texts.

The parameter is obligatory.

time unit

The parameter, given in decimal format, indicates which time unit has been
used as a value.

The parameter can have the following values:

1 Value in seconds.
2 Value in 10 milliseconds.

The default value is seconds.

For timers T3168 and T3192, the timer unit is either seconds or
milliseconds. The values of these timers are decimal values which indicate
the timer values from 0.5 to 4 seconds for timer T3168 and from 0.5 to 1.5
seconds for timer T3192 every half second. In these cases, the parameter
can have the following values:

DN9813203 # Nokia Siemens Networks 13 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

1 Value in seconds.
2 Value in milliseconds.

The default value is seconds.

timer value

The parameter, given in decimal format, indicates the new value of the
timer. The guidance text shows the name, current value, and value range
of the timer in the selected time unit.

Parts of seconds can only be given by using the 10 milliseconds time unit
(for timers T3168 and T3192).

The parameter is obligatory.

Examples 1. Modify the value of T4 to 10 seconds.

ZEGT:T4:,10; or ZEGT:T4:1,10;
2. Modify the value of T3107 to 3.50 seconds.
ZEGT:T3107:2,350;
3. Output the guidance text for the timer value of timer T3168 in
seconds.
ZEGT:T3168:1

/* IDENTIFY VALUE OF TIMER T3168


DECIMAL NUMERAL 0 ... 7

0 ... 0,5 s
1 ... 1,0 s
2 ... 1,5 s
3 ... 2,0 s
4 ... 2,5 s
5 ... 3,0 s
6 ... 3,5 s
7 ... 4,0 s

PARAMETERS CURRENT VALUE IS 1,0 S

PARAMETER IS OBLIGATORY */

Additional After completion of semantic checks, the MML writes the value to the
information PAFILE. If this is carried out successfully, the file is updated to the disks.
After updating the file, the file is distributed to other units. If these actions
are not successfully carried out, the previous value is applied and rewritten
to the file.

14 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
EGT MODIFY TIMER

Execution
printouts

COMMAND EXECUTED

The MML has updated the new value of the timer to the file.

Semantic error If an error occurs, the general semantic error messages of MML
messages commands are printed out.

Execution error
messages

/*** MODIFYING FAILED ***/

The MML is unable to modify the timer. The reason for the failure is stored
in the log file of the system.

/*** STORING FAILED ***/

The MML is unable to store the value of the timer in the file.

/*** MCMU - 01 NOT UPDATED ***/


/*** BCSU - 02 NOT UPDATED ***/
/*** TRY AGAIN ***/

The units that have not updated the file are listed. You can re-enter the
command to update the file and distribute it to other units.

DN9813203 # Nokia Siemens Networks 15 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

16 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008
EGP MODIFY PARAMETER

EGP MODIFY PARAMETER


Function With the command EGP you modify the value of the parameter.

Parameters parameter number: parameter value;

Syntax EGP: ( <parameter number> ) : ( <parameter value> ) ;

Parameter parameter number


explanations
The parameter indicates the parameter which is to be modified. The
names of the parameters and the corresponding numbers are displayed
on the output device.

The parameter is obligatory.

parameter value

The parameter indicates the new value of the parameter. The name of the
parameter, its current value, and the range of the value are displayed.

The parameter is obligatory.

Examples 1. Modify the value of the first parameter to 1.

ZEGP:1:1;
2. Modify the value of the sixth parameter to 1.
ZEGP:6:1;

Additional After completing semantic checks, the MML writes the value to the
information PAFILE. If this is carried out successfully, the file is updated to the disks.
After updating the file, the file is distributed to other units. If these actions
are not successfully carried out, the previous value is applied and rewritten
to the file.

DN9813203 # Nokia Siemens Networks 17 (18)


Issue 10-0 en
04/03/2008
EG - GSM Timer and BSC Parameter Handling

Execution COMMAND EXECUTED


printouts

The MML has updated the new value of the parameter to the file.

Semantic error If an error occurs, the general semantic error messages of MML
messages commands are printed out.

Execution error
messages

/*** MODIFYING FAILED ***/

The MML is unable to modify the parameter. The reason for the failure is
stored in the log file of the system.

/*** STORING PARAMETER FAILED ***/

The MML is unable to store the value of the parameter in the file.

/*** MCMU - 01 NOT UPDATED ***/


/*** BCSU - 02 NOT UPDATED ***/
/*** TRY AGAIN ***/

The units that have not updated the file are listed. You can re-enter the
command to update the file and distribute it to other units.

18 (18) # Nokia Siemens Networks DN9813203


Issue 10-0 en
04/03/2008

Anda mungkin juga menyukai