Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Organization: Organization:
DAIKIN INDUSTRIES, LTD. DAIKIN INDUSTRIES
AIR CONDITIONING MANUFACTURING DIVISION (THAILAND) LTD. All of the Daikin Group’s business
facilities and subsidiaries in Japan
Scope of Registration: Scope of Registration: are certified under the ISO 14001
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF THE DESIGN/DEVELOPMENT international standard for
COMMERCIAL AIR CONDITIONING, HEATING, COOLING, AND MANUFACTURE OF AIR environment management.
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, CONDITIONERS AND THE
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT COMPONENTS INCLUDING A special air conditioning system designed
JMI-0107 RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, JQA-1452 COMPRESSORS USED FOR THEM
COMPRESSORS AND VALVES. for small offices and shops
Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
COOLING ONLY
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
Cooling Only 50 Hz/60 Hz
c All rights reserved
08/12 Y.K.
Specifications, designs and other content appearing in this brochure are current as of August 2012 but subject to change without notice.
HEAT PUMP
Heat Pump 50 Hz/60 Hz
The ideal air conditioning system for
small offices and shops
Extending the core “5S” concept—Space saving, Sufficient capacity, Slim design, Sound-
reduced operation and Single phase power supply—Daikin’s VRVIII-S offers added value
with the “1E” concept—Easy installation. With all these features and more, we proudly
Volume
present the ideal air conditioning system designed for small-sized buildings.
Slim, compact and sufficient capacity Approx. 50%
The VRVIII-S is highly space saving, featuring slim and compact reduction
outdoor units. It is suitable for small offices and shops with capacities
of 4, 5 and 6 HP.
765 mm
320 mm
S
5S
concept Space saving
Sufficient capacity
Slim design
Sound-reduced operation
Single phase power supply
E
Outdoor unit can be installed
on a balcony
Easy installation The compact, trunk-shaped outdoor unit can easily
1E
concept
be installed on a balcony, realising complete system
installation within each floor. This enables more
useful utilisation of the space on the building rooftop.
Contents
Introduction.......... page 1 Indoor unit lineup..... page 15 Option list............ page 33
Indoor units......... page 33
Main features........ page 3 Specifications........... page 25 Outdoor units.......page 35
Indoor units............... page 25 Control systems...page 35
1
Control systems... page 9 Outdoor units............ page 32 2
MAIN FEATURES
Wide range of choices
To suit the variety of rooms found in small offices
Indoor units
14 types 71 models*
and shops, the VRVIII-S system offers wide range of
indoor and outdoor units. A wide range of indoor units includes
VRVIII-S indoor and outdoor units are almost as easy
71 models in 14 types. The indoor
units can be selected to match every
to install as residential air conditioning systems,
room and preference.
making them ideal for small offices and shops.
Outdoor units
3 models
Outdoor unit can be selected from three
models to provide the power that suits
your needs. The trunk-shaped outdoor unit
can be neatly installed outside the office.
FXDQ-PBVE
(with drain pump)
FXDQ-PBVET
(without drain pump) (700 mm width type)
Slim Ceiling
Mounted Duct
FXDQ-NBVE
(with drain pump)
FXDQ-NBVET
(without drain pump) (900/1,100 mm width type)
Ceiling Mounted
Duct FXMQ-PVE
Wall Mounted New FXAQ-PVE New New New New New New
Concealed
Floor Standing FXNQ-MAVE
Note: R-410A VRV system indoor units are not compatible with the R-22 VRV system.
*13 types and 68 models for 60 Hz specifications.
Note: BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data Book for details.
3 4
MAIN FEATURES
Energy efficiency and quiet operation A collection of cutting-edge technologies
Outdoor units use Daikin’s unique scroll compressor to realise energy saving
realises efficient and quiet operation.
performance and quiet operation. The high efficiency compressor to achieve a higher COP
1 Compressor equipped with Reluctance DC motor 3
High COP
achieved Daikin DC inverter models are equipped with the Reluctance DC
High COP during both cooling and in all ranges! motor for compressor. The Reluctance DC motor uses 2 different 2
compressor. 5 HP 3.41
70 More than 20% RX(Y)MQ4PVE
RX(Y)MQ5PVE
AC motor RX(Y)MQ6PVE
6 HP 3.19 60
Quiet operation provides Note: Data are based on studies conducted under
Lower operation sound is achieved controlled conditions at a Daikin laboratory
luxurious comfort in cooling operation! 1 dB(A) reduced
using Daikin products.
Starting time and ending time can be input. (An external DC motor efficiency
Step 1 max. - 3 dB(A) Efficiency improved in all areas compared (comparison with AC motor)
Step 1: 47 dB(A)
control adaptor for outdoor unit, DTA104A61 or ( 4 HP/11.2 kW)
100
DTA104A62, and a locally obtained timer are 47
Step 2 max. - 6 dB(A)
to conventional AC motors, especially at
necessary.) Step 2: 44 dB(A)
( 4 HP/11.2 kW) low speeds. 80
DC motor
Efficiency (%)
44
Step 3 max. - 9 dB(A) Approx.
Step 3: 41 dB(A) 60
Mode 3. Combined mode ( 4 HP/11.2 kW) DC fan motor structure 20%
41 increase
Combinations of modes 1 and 2 can be used Night mode starts Night mode ends 40 Approx.
depending on your needs. 8:00 12:00 16:00 20:00 0:00 4:00 8:00 40% AC motor
Note: Data are based on
*1. Initial setting. Can be selected from 6, 8 and 10 hours. Note: • This function is available in setting at site. 20 increase
studies conducted under
*2. Initial setting. Can be selected from 8, 9 and 10 hours. • The relationship of outdoor temperature (load) and time shown in the 0 controlled conditions at
graph is just an example.
200 300 400 500 600 700 800 900 1000 a Daikin laboratory.
The capacity reduction rate differs depending on the operation sound level
step selected.
Motor speed (rpm)
5 6
MAIN FEATURES
Design flexibility Easy installation
VRVIII-S systems offer broad design flexibility with long refrigerant piping lengths and A variety of functions are provided that make installation easier, such as simple wiring
multiple indoor unit combinations, which provides generous freedom for office and shop and piping and automatic test operation.
design both inside and out. Previous model
VRVII-S
For a 6 HP installation
Automatic test operation
Simply press the test operation button and the unit performs an automatic system check,
1 2 3 4
Max.
including wiring, shutoff valves, and sensors. The results are returned automatically after the
9 units
check finishes.
>> Max. 8 indoor units for a 5 HP
installation
5 6 7 8 9
>> Max. 6 indoor units for a 4 HP
installation
Simple wiring and piping connection
Unique piping and wiring systems make it possible to install a VRVIII-S system quickly and easily.
small-diameter piping.
Outdoor temperature (°CDB)
40
The versatile operation range of the VRVIII-S system 30 20 15.5°CWB
works to reduce limitations on installation locations. The 10
20
operation temperature range for heating goes all the way
0
down to -20°C, while cooling can be performed with 10
outdoor temperatures as high as 46°C. Both these 0 -10
achievements are due to the adoption of a high-pressure -5°CDB -20
-10 –20°CWB
dome-type compressor.
Cooling Heating
7 8
CONTROL SYSTEMS
Control systems
The VRVIII-S system uses the same DIII-NET communication system as the
VRV, enabling the use of advanced control systems.
Wired remote controller (Option) Wired remote controller Wireless remote Signal receiver unit
(Installed type)
controller
2 Remote control
Indoor unit Wired remote controller with
Remote controller The wiring of remote controller can be
Remote controller weekly schedule timer
extended to max. 500 m and it is possible (BRC1D61)
to install the remote controllers for the
different indoor units in one place.
Wireless remote controller*
(Installed type signal receiver unit)
Remote
controller 3 Control for the combined operation
The operation of Heat Reclaim Ventilator can
Forced OFF be controlled by the remote controller of the Wireless remote controller*
input (Separate type signal receiver unit)
indoor unit. Of course, the remote controller
can display the time to clean the filter.
Heat Reclaim
Ventilator
Remote
Simplified remote controller
Remote controller controller Remote controller (Exposed type)
Remote controller Remote controller 4 Expansion of system control (BRC2C51)
9 Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. *Refer to page 35 for the name of each model. 10
CONTROL SYSTEMS
Centralised control systems
Up to 64 groups of indoor units (128 units) can be centrally controlled.
Residential central remote controller* (Option)
Optional controllers for centralised control can be combined and optimised in Max. 16 groups of indoor units can be easily controlled with
accordance with building scale and purpose. the large LCD panel.
Max. 16 groups (128 indoor units) controllable
System integration with various air-conditioning peripheral equipment such as Backlight and large LCD panel for easy readability
ON/OFF, temperature settings and scheduling can be controlled individually for indoor units.
Heat Reclaim Ventilator is easy. All indoor units can be turned on or off at once with “ALL” button.
Each group has a dedicated button for convenience.
Outside temperature display
Wiring can be run up to a total length of 2 km, and adapts easily to large-scale DCS303A51
*For residential use only. Cannot be used with other centralised control equipment.
system expansion.
11 12
CONTROL SYSTEMS
Advanced control systems
New
Internet
Intranet LAN iTM plus adaptor line iTM plus adaptor (Max. 7 adaptors)
Max. 50m
Web Access
Lighting Pump Fan Sensor
Features Features
Central control
• Handy area settings simplify detailed management of VRV. Colour LCD touch panel icon display
• Display of floor plans enables a quick search of desired air conditioning units.
• Operation history shows manner of control and origin in past operations of air conditioning units. Small manageable size
Remote access
• Remote access with a PC allows total air conditioning management using the same type of screens as those displayed in the Simplified engineering
intelligent Touch Manager.
Multi language (English, French, Italian, German,
• Authorised users can centrally control individual air conditioning units from their own computers.
Automatic control Spanish, Dutch, Portuguese, Chinese and Korean)
• VRVs are controlled automatically throughout the year by the schedule function.
• Interlocking VRVs and other equipment enables easy automation of building facilities operation. Yearly schedule
• Setback adjusts temperature settings even when rooms are unoccupied.
Energy management
Auto heat/cool change-over
• The Energy Navigator feature simplifies energy management by tracking energy consumption data and identifying inefficient Temperature limitation
operation.
Troubleshooting Enhanced history function
• Contact information of maintenance contractors can be registered and displayed.
• E-mails are sent automatically to alert of malfunctions and potential trouble. Simple Interlock Function
• The intelligent Touch Manager can link to the Air Conditioning Network Service System for 24-hour monitoring of operating Built-in modem for connecting to Air Conditioning Network Service System (Option)
conditions and status.
Scalability Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)
• A single intelligent Touch Manager can manage a small building or be expanded to handle medium- to large-sized buildings.
• Large building properties can also take advantage of the iTM integrator to link up and expand system up to 5 intelligent Touch Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit)
Managers for integrated control.
13 14
INDOOR UNIT LINEUP
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Round Flow) Type (Compact Multi Flow) Type
FXFQ25P/ FXFQ32P/ FXFQ40P
FXZQ20M/FXZQ25M
FXFQ50P/ FXFQ63P/ FXFQ80P
FXZQ32M/FXZQ40M
FXFQ100P/ FXFQ125P
FXZQ50M
FXZQ-M 20/25 32 40 50
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet.
15 16
INDOOR UNIT LINEUP
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Double Flow) Type Corner Type
FXCQ20M/ FXCQ25M / FXCQ32M FXKQ25MA/FXKQ32MA
FXCQ40M/ FXCQ50M / FXCQ63M FXKQ40MA/FXKQ63MA
FXCQ80M/ FXCQ125M
and a detachable blade make cleaning easy. A long-life filter (maintenance free up to one
year ) is equipped as standard accessory.
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
17 18
INDOOR UNIT LINEUP
Slim Ceiling Mounted Ceiling Mounted
Duct Type Duct Type
FXMQ20P/FXMQ25P/FXMQ32P
Slim design, quietness and FXMQ40P/FXMQ50P/FXMQ63P
FXMQ80P/FXMQ100P/FXMQ125P
static pressure switching FXMQ140P
28 kg.
19 20
INDOOR UNIT LINEUP
Ceiling Suspended Type Wall Mounted Type
FXAQ20P/FXAQ25P
FXHQ32MA / FXHQ63MA New FXAQ32P/FXAQ40P
FXHQ100MA
FXAQ50P/FXAQ63P
FXHQ-MA 32 63 100
Sound level
Drain pan and air filter can be kept clean by
36/31 39/34 45/37
(H/L) mould-proof polystyrene.
Installation is easy
Vertical auto-swing realises efficiency of air
Drain pump kit (option) can be easily
distribution. The louvre closes automatically
incorporated. when the unit stops.
600 mm
Maintenance is easy 5 steps of discharge angle can be set by
Non-dew Flap with no implanted bristles remote controller.
Drain pump kit
(built inside main unit) Bristle-free Flap minimises
contamination and makes
Drain pump kit is available as optional accessory,
cleaning simpler. Discharge angle is automatically set at the which lifts the drain 1,000 mm from the bottom of
Wide air discharge openings produce a Non-dew Flap
same angle as the previous operation when the unit.
spreading 100° airflow. Easy-to-clean flat design restarting. (Initial setting: 10˚ for cooling and
Height of drain-up
70˚ for heating)
Maintenance is easier because servicing can
be performed from below the unit.
1,000 mm
Flexible installation
A long-life filter (maintenance free up to one
year) is equipped as standard accessory. Drain pipe can be fitted to from either left or
right sides. Indoor unit
100° Drain pump kit
21 22
INDOOR UNIT LINEUP
Connection unit series indoor units
Concealed Floor
Standing Type Only one unit is needed to distribute comfortable air
throughout an L-shaped store.
FXNQ20MA / FXNQ25MA
FXNQ32MA / FXNQ40MA
FXNQ50MA / FXNQ63MA
Connection unit Connection unit is the device for connecting above indoor unit to VRVIII-S.
Designed to be concealed in the perimeter skirting-wall
BEVQ71MA/BEVQ100MA/BEVQ125MA
The unit is concealed in skirting-wall of perimeter, that enables
Refrigerant piping layout External wiring layout *1
to create high class interior design. Maximum piping length
Connection unit for indoor unit Model between the BEV unit
and the indoor unit.
FXUQ-MA 5m
The connecting port faces VRV -S series
outdoor unit
Notes:
downward, greatly facilitating Gas pipe
BEVQ-MAVE Super wiring (DIII-NET) • When connecting centralised-control device, it is
Liquid necessary to install an interface adaptor for an
Connecting Single-phase 220-240 V
on-site piping work. port
pipe
power supply indoor unit (DTA102A52).
• Connection unit BEVQ-MA is necessary for each
Indoor unit indoor unit.
Refrigerant • The refrigerant piping height difference between
A long-life filter (maintenance piping the indoor units and the BEV unit must be within
4 m.
• The BEV unit must be installed within a
free up to one year ) is equipped Piping length*1 Indoor unit maximum height difference between indoor units
Applies also to Floor Standing type (FXLQ-MA). of 15 m.
as standard accessory. Remote controller • Branching of the refrigerant piping is not
possible downstream of the BEV unit.
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
23 24
SPECIFICATIONS
INDOOR UNITS Ceiling Mounted Cassette (Double Flow) Type
MODEL FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE
Ceiling Mounted Cassette (Round Flow) Type Power supply 1-phase, 220 - 240 V/220 V, 50/60 Hz
MODEL FXFQ25PVE FXFQ32PVE FXFQ40PVE FXFQ50PVE FXFQ63PVE FXFQ80PVE FXFQ100PVE FXFQ125PVE kcal/h (*1) 2,000 2,500 3,200 4,000 5,000 6,300 8,000 12,500
Btu/h (*1) 7,800 9,900 12,600 16,000 19,800 24,900 31,700 49,500
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz Cooling capacity
(*1) 2.3 2.9 3.7 4.7 5.8 7.3 9.3 14.5
kcal/h(*1) 2,500 3,200 4,000 5,000 6,300 8,000 10,000 12,500 kW
(*2) 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
Btu/h(*1) 9,900 12,600 16,000 19,800 24,900 31,700 39,600 49,500
Cooling capacity kcal/h 2,200 2,800 3,400 4,300 5,400 6,900 8,600 13,800
(*1) 2.9 3.7 4.7 5.8 7.3 9.3 11.6 14.5
kW Heating capacity Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 34,100 54,600
(*2) 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0
kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0
kcal/h 2,800 3,400 4,300 5,400 6,900 8,600 10,800 13,800
Heating capacity Btu/h 10,900 13,600 17,100 21,500 27,300 34,100 42,700 54,600 Power consumption Cooling 0.077/0.081 0.092/0.095 0.092/0.095 0.130/0.132 0.130/0.132 0.161/0.157 0.209/0.216 0.256/0.278
kW
(50 Hz/60 Hz) Heating 0.044/0.048 0.059/0.062 0.059/0.062 0.097/0.099 0.097/0.099 0.126/0.124 0.176/0.183 0.223/0.245
kW 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0
Casing Galvanised steel plate
Power consumption Cooling 0.033/0.032 0.033/0.032 0.047/0.042 0.052/0.050 0.066/0.063 0.093/0.092 0.187/0.186 0.209/0.208
kW m3/min 7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25
(50 Hz/60 Hz) Heating 0.027/0.027 0.027/0.027 0.034/0.034 0.038/0.038 0.053/0.053 0.075/0.075 0.174/0.174 0.200/0.200 Airflow rate (H/L)
cfm 247/177 318/230 318/230 424/318 424/318 582/459 918/741 1,165/883
Casing Galvanised steel plate
220 V 32/27 34/28 34/28 34/29 34/29 37/32 39/34 44/38
m3/min 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5 Sound level (H/L) dB(A)
Airflow rate (HH/H/L) 240 V 34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40
cfm 459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794
Dimensions (HXWXD) mm 305X775X600 305X775X600 305X775X600 305X990X600 305X990X600 305X1,175X600 305X1,665X600 305X1,665X600
Sound level (HH/H/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34
Machine weight kg 26 26 26 31 32 35 47 48
Dimensions (HXWXD) mm 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 288X840X840 288X840X840
Liquid (Flare) 6.4 6.4 6.4 6.4 6.4 9.5 9.5 9.5
Machine weight kg 19.5 19.5 19.5 19.5 22 22 25 25 Piping
mm
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7 15.9 15.9 15.9
Liquid (Flare) 6.4 6.4 6.4 6.4 9.5 9.5 9.5 9.5
Drain VP25 (External Dia, 32/Internal Dia, 25)
Piping
mm
connections Gas (Flare) 12.7 12.7 12.7 12.7 15.9 15.9 15.9 15.9
Model BYBC32G-W1 BYBC50G-W1 BYBC63G-W1 BYBC125G-W1
Drain VP25 (External Dia, 32/Internal Dia, 25)
Panel Colour White (10Y9/0.5)
Model BYCP125K-W1 (Option) Dimensions (HXWXD) mm 53X1,030X680 53X1,030X680 53X1,030X680 53X1,245X680 53X1,245X680 53X1,430X680 53X1,920X680 53X1,920X680
Panel Colour Fresh white
Weight kg 8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0
(Option) Dimensions (HXWXD) mm 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950
Weight kg 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Ceiling Mounted Cassette Corner Type
Ceiling Mounted Cassette (Compact Multi Flow) Type MODEL FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE
MODEL FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE Power supply 1-phase, 220 - 240 V/220 V, 50/60 Hz
29 30
SPECIFICATIONS
Connection unit series indoor units
OUTDOOR UNITS
* A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data Book for details.
* If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other
series, cooling/heating switchover will not be possible using the remote controller of the Connection unit series indoor units. Cooling Only
However, if the remote controller of an indoor unit from the other series is set as a master remote controller, cooling/heating
MODEL RXMQ4PVE RXMQ5PVE RXMQ6PVE
switchover will be possible.
* If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable Power supply 1-phase, 220-230 V, 50 Hz/220 V 60 Hz
cooling/heating switchover. Kcal/h 9,600 12,000 13,300
* Group control between Connection Unit series equipment within one system is possible. However, group control with the other Cooling capacity Btu/h 38,200 47,700 52,900
VRV indoor units is not possible. kW 11.2 14.0 15.5
Power consumption kW 2.95 3.97 4.44
Capacity control % 24 to 100
Ceiling Suspended Cassette Type (50 Hz only) Casing colour Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type
Compressor
Motor output kW 2.5 3.0 3.5
Indoor unit FXUQ71MAV1 FXUQ100MAV1 FXUQ125MAV1 3
MODEL Airflow rate m /min 106
Connection unit BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE Dimensions (H x W x D) mm 1,345 x 900 x 320
Power supply 1-phase, 220-240 V, 50 Hz Machine weight kg 125
Kcal/h(*1) 7,100 10,000 12,500 Sound level dB(A) 50 51 53
Btu/h(*1) 28,300 39,600 49,500 Operation range °CDB -5 to 46
Cooling capacity
(*1) 8.3 11.6 14.5 Type R-410A
kW Refrigerant
(*2) 8.0 11.2 14.0 Charge kg 4.0
Kcal/h 7,700 10,800 12,000 Piping Liquid ø9.5 (Flare)
mm
Heating capacity (Max.) Btu/h 30,700 42,700 47,800 connections Gas ø15.9 (Flare) ø19.1 (Brazing)
kW 9.0 12.5 14.0
31 32
OPTION LIST
INDOOR UNITS
Ceiling Mounted Cassette (Round Flow) Type Ceiling Mounted Duct Type
No. Type FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P No. Type FXMQ20P FXMQ50P FXMQ100P
Item Item FXMQ25P FXMQ40P FXMQ63P FXMQ125P
1 Decoration Panel BYCP125K-W1 FXMQ32P FXMQ80P FXMQ140P
2 Sealing member of air discharge outlet KDBH55K160F 65% KAF372AA36 KAF372AA56 KAF372AA80 KAF372AA160
3 Panel spacer KDBP55H160FA 1 High efficiency filter
90% KAF373AA36 KAF373AA56 KAF373AA80 KAF373AA160
High efficiency filter unit 65% KAFP556B80 KAFP556B160
2 Filter chamber KDDF37AA36 KDDF37AA56 KDDF37AA80 KDDF37AA160
High efficiency filter unit 90% KAFP557B80 KAFP557B160
Replacement high efficiency filter 65% KAFP552B80 KAFP552B160 3 Long life replacement filter KAF371AA36 KAF371AA56 KAF371AA80 KAF371AA160
Replacement high efficiency filter 90% KAFP553B80 KAFP553B160 4 Long life filter chamber kit KAF375AA36 KAF375AA56 KAF375AA80 KAF375AA160
4 Filter related
Filter chamber KDDFP55B160 White KTBJ25K36W KTB25KA56W KTB25KA80W KTB25KA160W
Long life replacement filter Non-woven type KAFP551K160 5 Service panel Fresh white KTBJ25K36F KTBJ25K56F KTBJ25K80F KTBJ25K160F
Ultra long-life filter KAFP55B160
Replacement ultra long-life filter KAFP55H160H Brown KTBJ25K36T KTBJ25K56T KTBJ25K80T KTBJ25K160T
Without T shape and fan KDDP55B160 6 Air discharge adaptor KDAJ25K36A KDAJ25K56A KDAJ25K71A KDAJ25K140A
Chamber type
5 Fresh air intake kit With T shape without fan KDDP55B160K
Direct installation type KDDP55X160
6 Branch duct chamber KDJP55B80 KDJP55B160 Ceiling Suspended Type
7 Chamber connection kit KKSJ55KA160
No. Type FXHQ32MA FXHQ63MA FXHQ100MA
8 Insulation kit for high humidity KDTP55K80 KDTP55K160 Item
1 Drain pump kit KDU50N60VE KDU50N125VE
2 Replacement long-life filter (Resin net) KAF501DA56 KAF501DA80 KAF501DA112
Ceiling Mounted Cassette (Compact Multi Flow) Type 3 L-type piping kit (for upward direction) KHFP5MA63 KHFP5MA160
No. Item Type FXZQ20M FXZQ25M FXZQ32M FXZQ40M FXZQ50M
1 Decoration panel BYFQ60B8W1
2 Sealing member of air discharge outlet KDBH44BA60 Wall Mounted Type
3 Panel spacer KDBQ44BA60A No. Type FXAQ20P FXAQ25P FXAQ32P FXAQ40P FXAQ50P FXAQ63P
Replacement long-life filter KAFQ441BA60
Item
4
1 Drain pump kit K-KDU572EVE
5 Fresh air intake kit Direct installation type KDDQ44XA60
33 34
OPTION LIST
OUTDOOR UNITS CONTROL SYSTEMS
Cooling only System Configuration
Type
No. Item RXMQ4P RXMQ5P RXMQ6P No. Item Model No. Function
Note 3
1 Cool/Heat Selector KRC19-26A •Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF,
1 Residential central remote controller DCS303A51
temperature settings and scheduling can be controlled individually for indoor units.
5 Fixture for preventing overturning KPT-60B160 3-2 Noise filter (for electromagnetic interface use only) KEK26-1A
Note 2
6 Wire fixture for preventing K-KYZP15C •Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units
4 Schedule timer DST301BA61 (128 units). Can turn units ON/OFF twice per day.
CONTROL SYSTEMS 1-1 Option Hardware DIII-NET plus adaptor DCS601A52 •Additional 64 groups (10 outside units) is possible.
1-2 Electrical box with earth terminal (4 blocks) KJB411A •Wall embedded switch box.
3 Wired remote controller with weekly schedule timer BRC1D61 2-5 Di unit DEC101A51 •8 pairs based on a pair of On/Off input and abnormality input.
•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-
8 Remote sensor (for indoor temperature) KRCS01-4B KRCS01-1B KRCS01-4B KRCS01-1B 4 *2 Interface for use in LONWORKS ®
DMS504B51
conditioning systems through LONWORKS communication.
®
Note 2,3 Note 4.6 Note 2,3 Note 4,6 Note 2,3 Note 3 Note 2,3
9 Installation box for adaptor PCB KRP1H98 KRP1BA101 KRP1B96 — KRP1BA101 KRP4A96 KRP1CA93 KRP4AA93 — KRP1BA97 5
Contact/analogue Unification adaptor for
DCS302A52 •Interface between the central monitoring board and central control units.
signal computerised control
10 External control adaptor for outdoor unit DTA104A62 DTA104A62 DTA104A61 DTA104A61 DTA104A53 DTA104A61 DTA104A62 DTA104A61 DTA104A61 — ®
Notes: *1. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
*2. LONWORKS is a trademark of Echelon Corporation registered in the United States and other countries.
®
11 Adaptor for multi tenant DTA114A61 — DTA114A61 — DTA114A61 — *3. Installation box for adaptor must be obtained locally.
Note: 1. Installation box is necessary for each adaptor marked . 3. Only one installation box can be installed for each indoor unit. 5. Installation box is necessary for second adaptor.
2. Up to 2 adaptors can be fixed for each installation box. 4. Up to 2 installation boxes can be installed for each indoor unit. 6. Installation box is necessary for each adaptor.
35 36
MEMO