Anda di halaman 1dari 31

Copyright Sophic Automation Sdn. Bhd.

1
How Monnit Works?

Copyright Sophic Automation Sdn. Bhd. 2


System Architecture

Copyright Sophic Automation Sdn. Bhd. 3


Monnit Wireless Quad Temperature
Sensor
• Four independent temperature probes
to measure and track multiple
temperatures with one device

• Sensor data is stored in the iMonnit


Online Sensor Monitoring and Notification
System and can be reviewed and exported
as needed from web

• Set notifications and alerts from the system so you can know
immediately if temperatures are above or below an optimal range

Copyright Sophic Automation Sdn. Bhd. 4


Monnit Wireless Duct Temperature
Sensor
• Accurately measure
temperatures in duct work,

• The sensor will measure temperature


in the duct work and send data to the
iMonnit Online Sensor Monitoring and
Notification System

• The data is stored in the online system and


can be reviewed and exported as a data
sheet or graph

• Allows you to set notifications and alerts from the system so you
can know immediately if temperatures are above or below an
optimal range

• Probe temperature range of -40°C to +150°C ( -40°F to +302°F )


Copyright Sophic Automation Sdn. Bhd. 5
Monnit Wireless Humidity Sensor

• Monitor relative humidity of air within a room or


enclosure

• Ideal for monitoring humidity within


greenhouses, industrial spaces, museums, saunas

Copyright Sophic Automation Sdn. Bhd. 6


Monnit Wireless Liquid Level Sensor

• Measure the level of a liquid in a container

• Able to set the frequency of sensor readings and the


ability to set thresholds for notifications and alerts from
the iMonnit online sensor monitoring system

Copyright Sophic Automation Sdn. Bhd. 7


How The System
Works?
• Use up to 100 wireless sensors with one
Monnit gateway
• Different versions available - Cellular
Gateway (CDMA or GSM) - Ethernet
Gateway - USB Gateway - Serial MODBUS
Gateway
• Cellular gateways are available with 24
hour battery backup
• 250 - 300 ft. device range

• Over 50 sensor types available


• 250 - 300 ft. device range
• Up to 10 years battery life

Copyright Sophic Automation Sdn. Bhd. 8


How The System
Works?

Copyright Sophic Automation Sdn. Bhd. 9


Why Choose Monnit?
Easy to Setup and Use

• Monnit remote monitoring systems can be setup in just a few minutes

Exceptional Wireless Range

• Provides superior wireless range for covering large areas

Low Cost

• Online sensor monitoring and notifications are FREE!

Low Power / Long Life

• Monnit wireless sensors feature industry leading power management, allowing


sensors to last for up to 10 years

Global RF Frequencies

• Wireless products are available in global frequencies (900, 920, 868 and 433 MHz)
Copyright Sophic Automation Sdn. Bhd. 10
Getting Started

Setting Up Your iMonnit Account and


Wireless sensor network

Copyright Sophic Automation Sdn. Bhd. 11


Step 1: Login
1. Go to monnit website : www.imonnit.com
2. Enter Username : kk.sjaya
Password : kksj1234

Copyright Sophic Automation Sdn. Bhd. 12


Step 2: Add Gateway
2a

1. Switch on the Monnit Link Cellular Gateway wireless sensors


2. Go to Manage -> Add Gateway

Copyright Sophic Automation Sdn. Bhd. 13


Step 2: Add Gateway
2b

Fill in the required details and press the ‘Assign Gateway’ button

The Gateway ID can be found


on the bottom of the QR code
label located on the gateway

Press Assign Gateway


2 to assign the gateway
in the network
The Gateway Code can be found
on the bottom of the QR code 3
label (The security code consists
of all letters, no number) Copyright Sophic Automation Sdn. Bhd. 14
2c Step 2: Add Gateway

Gateway successfully added


Copyright Sophic Automation Sdn. Bhd. 15
3a Step 3: Assign Sensor
1. Switch on the wireless sensor
2. Go to Manage -> Add Sensor

Press
Copyright Sophic Automation ‘Add
Sdn. Bhd. Sensor’ button 16
3b Step 3: Assign Sensor
Fill in the required details and press the ‘Assign Sensor’ button. For this tutorial, we use
the humidity wireless sensor
The Sensor ID can be found
on the back of the sensor

2 3
The Sensor Code can be found on
the back of the sensor (all letters,
no numbers)
Copyright Sophic Automation Sdn. Bhd. 17
3c Step 3: Assign Sensor
Fill in the required details and press the ‘Continue’ button.

Copyright Sophic Automation Sdn. Bhd. 18


3d Step 3: Assign Sensor
1. The message will pop up when sensor is assigned successfully
2. Click Done button

Sensor assigned
successfully

Copyright Sophic Automation Sdn. Bhd. 19


3e Step 3: Assign Sensor

Reading
of the
humidity
is
displayed

The system get data every 1 minute and display data


in the web for every 10 minute
Copyright Sophic Automation Sdn. Bhd. 20
3f Step 3: Assign Sensor
Click on Manage button to check the status of the sensor

Not
Connected

Copyright Sophic Automation Sdn. Bhd. Connected


21
4a Step 4: Add notification to the sensor
Go to Notifications -> Add Notification

1 2

Go to Sensor Reading Notification -> Select Type of Sensor

Copyright Sophic Automation Sdn. Bhd. 22


4b Step 4: Add notification to the sensor
Fill in the required information

Insert the
notification name

Insert the
notification text

Select the alert


condition

Press enter when all


necessary data
Copyright Sophic Automation Sdn. Bhd. fulfilled 23
4c Step 4: Add notification to the sensor

Tick the triggering


sensor

Copyright Sophic Automation Sdn. Bhd. 24


4d Step 4: Add notification to the sensor

Tick the triggering


sensor

Copyright Sophic Automation Sdn. Bhd. 25


5a Step 5: Monitoring the data
1. Go to Overview -> Select the type of sensor
2. Choose the visualization representation based on the menu button

Copyright Sophic Automation Sdn. Bhd. 26


Step 5: Monitoring the data

Copyright Sophic Automation Sdn. Bhd. 27


Step 6: Change Fahrenheit to Celsius
1. Choose the sensor
2. Select the Scale button
3. Change the ‘Fahrenheit’ to ‘Celsius’
4. Click save button
5. Click continue button

3 4

Copyright Sophic Automation Sdn. Bhd. 28


Change from fahrenheit to Celsius
Step 7: Export data
1. Go to overview
2. Select the sensor
3. Press Export menu bar
4. Press Export data to csv file

Copyright Sophic Automation Sdn. Bhd. 29


Step 8: Edit the data setting
1. Go to overview
2. Select the sensor
3. Press Edit menu bar
4. Change/ edit the data
5. Press Save button

Edit/Change

Copyright Sophic Automation Sdn. Bhd. 30


Class Activity
• In a group, discuss an idea of a project using
the following wireless monnit sensors

1) Monnit Wireless Humidity Sensor


2) Monnit Wireless Liquid Level Sensor
3) Monnit Wireless Duct Temperature Sensor
4) Monnit Industrial Wireless Quad
Temperature Sensor
Copyright Sophic Automation Sdn. Bhd. 31

Anda mungkin juga menyukai