1 Measurements Tab
Digital Energy Monitoring & Diagnostics
During an analysis, the serial number and operational state of the Next create a new database: To download from the device right click the device in the Asset This tab displays results stored in the device.
TRANSFIX will be displayed on the LCD. Explorer within Perception and select Download. You can see the 1
File > New Database > [Enter database name] progress of the download in the device Properties tab within the
[ENTER] 2
Quick Start Guide 1 Quick Start Guide 2 Quick Start Guide 3 Quick Start Guide 4 Quick Start Guide 5 Quick Start Guide 6
4.2 DGA Scheduling Tab 4.3 Configuring Alarms 5. Viewing Results Using PERCEPTION 5.3 Trend Chart 6.2 Gas Ratios* 6.4 Total Dissolved Combustible Gas (TDCG)*
This tab is used to configure the measurement interval. Once a In PERCEPTION, clicking on the device will display the following tabs. Displays results in graphical form, points can be added/removed by Seleting this tab displays a 3D rotatable Gas Ratio Diagram as per Provides TDCG analysis
device exceeds the levels set in the Alarms tab, it will enter Caution right clicking the graph. Custom Ratios trend charts are available in IEC 60599 or IEE C57.104. The ratio table option shows Doernenburg,
and Alarm Modes and automatically accelerate the measurement 5.1 Status Perception Desktop. Rogers and C57.104 Transformer conditions ratios.
frequency.
1 Displays the current state of the device, with alarm levels indicating
any caution/alarm readings.
2
Japanese ETRA diagram is also available. For further information consult the user guide
or GEDigitalEnergy.com/MD.htm.
*Diagnostic feature not available in PERCEPTION EXPRESS
3 6. Diagnosis of Data using PERCEPTION DESKTOP*
4
5.2 Data Table 6.1 Duvals Triangle* 6.3 Key Gas* Maintenance
Recommended Settings Displays results in tabular format highlighting any caution/alarm Selecting this tab displays Duvals triangle with historical plotting Consult the user guides for details of air intake and oil filter cleaning.
This compares the DGA results to profiles of known faults as per IEEE
Recommended settings for TRANSFIX / MINITRANS are: readings. measurements included. The drop down tab on the right hand side C57.104. Statistical analysis is provided to assist the user. Error Codes as displayed on LCD Screen
allows switching to Duvals Tap Changer Triangle.
Normal Mode: 4 Hrs 01 Missing mains input 14 Gas leak test: Pump pressure too low
02 PGA power supply voltage too low 15 Gas leak test: Pressure decay too high
Caution Mode: 2 Hrs 03 PGA chopper frequency outside range 16 Oil temperature too low
This tab is used to configure the alarm settings on the device. 04 PGA IR-source outside range 17 Oil temperature too high
Alarm Mode: 1 Hr 05 Gas flow lower than limit 18 Oil pressure too low
1. Separate Caution & Alarm tab’s and several User Alarm tabs 06 Background noise/vibration too high 19 Oil pressure too high
2. User Configurable Alarm Limits 07 Microphone test failed 20 Oil pump tacho count too high
Recommended settings for TAPTRANS / MULTITRANS are:
08 No levelsensor1 signal (oil level) 21 Oil pump pressure too low
Normal Mode: 6 Hrs 3. Rate of Change (ROC) time window & minimum number of samples 09 No Levelsensor3 signal (oil drain) 22 Oil pump speed out of range
for ROC calculation 10 Levelsensor1 signal (oil level) 23 Manual oil sampling switch
Caution Mode: 3 Hrs 4. Alerts – Alert sent when the Alarm Condition (Limit) is reached
11 Levelsensor2 signal (oil level alert) 24 Oil pump tacho count too low
12 PGA Air temperature outside limits 25 Oil pump not turning
Alarm Mode: 1 Hr Click on Apply to apply any changes. The device will reset but will 13 Bad communication with controlboard
not affect any measurement in progress. Click on Exit to close the
connection and return to PERCEPTION to view the results.
*Diagnostic feature not available in PERCEPTION EXPRESS *Diagnostic feature not available in PERCEPTION EXPRESS GEDigitalEnergy.com