1)
Mining Engineering
A concentrically loaded member subjected to a design
axial compression (N*) shall satisfy both:
b fy
λe =
t 250
be b
Effective width of flat plate element (Clause 6.2.4):
λ t
be = b ey ≤ b t
λe
be b
Ae = Ag − ∑ ({b − be }t )i
n
i =1
- ineffective area
n : number of plate elements
Ae
kf =
Nominal section capacity (Clause 6.2): N s = k f An f y Ag
3 4
Nominal Member Capacity (Clause 6.3):
2
90
Member slenderness reduction factor: α c = ξ 1 − 1 −
ξλ
λ
2
+1+η
ξ =
90 λ = λn + α aα b η = 0.00326(λ − 13.5) ≥ 0
λ
2
2
90
l fy 2100(λn − 13.5)
λn = e k f αa =
r λ − 13.5λn + 2050
2
250 n
7 The table covers a wide rage of value (0 to 600 with and interval of 5 ) of λn 8
Different boundary conditions – Effective length concept Member Buckling Analysis (Clause 4.6)
π 2 EI
Elastic buckling load of a member (Clause 4.6.2): N om =
(kel )2
2π 2 EI 4π 2 EI
π 2 EI P cr = P cr =
P cr = L2 L2
L2
π EI
2
P cr =
4 L2 π 2 EI Figure 4.6.3.2 Effective length factors (ke) of members with idealized
Generalized buckling load: P cr = L e : Effective length 9 10
L2e conditions of end restraints (Clause 4.6.3.2)
10
Example 1: Calculate the nominal member capacity of a column having the Ag = An = 10160 mm2
cross-section as shown. The column has a length of 6 m and its two end are
strongly encased within solid concrete slabs. 150 150
Compression flange: be = 126.3 mm
8 8
10
Gross cross-sectional area: x x
500
Web plate : λe = 79 λey = 45
150 150 Ag = 2 × [(150 × 2 + 8) × 10] + 500 × 8 f y = 400 MPa
λ 45
= 10160 mm2 be = b ey = 500 × = 284.8 mm
8 8 λ
e 79
Net cross-sectional area:
500
An = Ag (as there are no holes due to bolts etc) 10
f y = 400 MPa
n
Compression flange: Effective cross-sectional area: Ae = Ag − ∑ ({b − be }t )i
i =1
b f y 150 400
10 λe = = = 19 Ae = 10160 − 4 × [(150 − 126.3) × 10 − (500 − 284.8) × 8 = 7490.4 mm2
t 250 10 250
Web plate :
λey = 16 λe > λey Ae 7490.4
b f y 500 400 Table 6.2.4: Form factor: k f = = = 0.737
λe = = = 79 Ag 10160
t 250 8 250
λ 16
λe > λey be = b ey = 150 × = 126.3 mm Nominal section capacity: N s = k f An f y = 0.737 × 10160 × 400 / 1000 = 2995 kN
Table 6.2.4: λey = 45 λe 19 11 12
y k f = 0.737 λn = 65.86 α b = 0 .5 N s = 2995 kN
10
150 150
Ag = An = 10160 mm2 2100(λn − 13.5) 2100 × (65.86 − 13.5)
αa = = = 20
10 × (150 × 2 + 8)3 λ2n − 13.5λn + 2050 (65.86) 2 − 13.5 × 65.86 + 2050
8 8 Iy = 2×
12
x x 500 6m
500 × (8)3 λ = λn + α aα b = 65.86 + 20 × 0.5 = 75.86
+ = 4872 × 104 mm 4
12
f y = 400 MPa
η = 0.00326(λ − 13.5) = 0.00326 × (75.86 − 13.5) = 0.2 ≥ 0 (OK)
Iy 4872 × 104
ry = =
λ
A 10160 2 2
75.86 From Table 6.3.3(3)
+1+η
10
y = 69.25 mm + 1 + 0.2
ξ= 90 = 90
= 1.35 α c = 0.714
Nominal member capacity: N c = α c N s ≤ N s λ
2
75.86
2