Modules : SPR-327NE-WHT-D
Type: Monocrystalline
Configuration: 6 Strings
Temp. Coeffiecent of Pmax = -0.38% / oC
Temp. Coeffiecent of Voc = -176.6mV / oC
Temp. Coeffiecent of Isc= 3.5mA / oC
Port A:
Effiency Test 1st Run 2nd Run
Nominal Power 18312.00 18312.00
Solar Irradiance (W/m2) 894.00 887.00
Peak Sun Factor 0.89 0.89
Module Temperature (oC) 60 60
Temperature Factor 0.8670 0.8670
System Losses (Cable, Inverter, Etc.) 0.95 0.95
Port B:
Effiency Test 1st Run 2nd Run
Nominal Power
Solar Irradiance (W/m2) 731.00 744.00
Peak Sun Factor 0.73 0.74
Module Temperature (oC) 46 46.4
Temperature Factor 0.9202 0.9187
System Losses (Cable, Inverter, Etc.) 0.95 0.95
60
3rd Run
18312.00
18312
0.00
14
1.0950
0.95
0.00
3100.00
#DIV/0!
90%
46
3rd Run
737.00
0.74
46.4
0.9187
0.95
0.00
3090.00
#DIV/0!
90%
PV Array 2:
Modules : SPR-327NE-WHT-D
Type: Monocrystalline
Configuration: 6 Strings
Temp. Coeffiecent of Pmax = -0.38% / oC
Temp. Coeffiecent of Voc = -176.6mV / oC
Temp. Coeffiecent of Isc= 3.5mA / oC
String 2A:
Effiency Test 1st Run 2nd Run
Nominal Power 4905.00 4905.00
Solar Irradiance (W/m2) 788.00 791.00
Peak Sun Factor 0.79 0.79
Module Temperature (oC) 48.4 47.9
Temperature Factor 0.9111 0.9130
System Losses (Cable, Inverter, Etc.) 0.95 0.95
String 2B:
Effiency Test 1st Run 2nd Run
Nominal Power 4905.00 4905.00
Solar Irradiance (W/m2) 810.00 797.00
Peak Sun Factor 0.81 0.80
Module Temperature (oC) 48.3 48.3
Temperature Factor 0.9115 0.9115
System Losses (Cable, Inverter, Etc.) 0.95 0.95
String 3C:
Effiency Test 1st Run 2nd Run
Nominal Power 4905.00 4905.00
Solar Irradiance (W/m2) 808.00 815.00
Peak Sun Factor 0.81 0.82
Module Temperature (oC) 48.5 48.8
Temperature Factor 0.9107 0.9096
System Losses (Cable, Inverter, Etc.) 0.95 0.95
String 2D:
Effiency Test 1st Run 2nd Run
Nominal Power 4905.00 4905.00
Solar Irradiance (W/m2) 820.00 845.00
Peak Sun Factor 0.82 0.85
Module Temperature (oC) 48.9 49.4
Temperature Factor 0.9092 0.9073
System Losses (Cable, Inverter, Etc.) 0.95 0.95
String 2E:
Effiency Test 1st Run 2nd Run
Nominal Power 4905.00 4905.00
Solar Irradiance (W/m2) 844.00 856.00
Peak Sun Factor 0.84 0.86
Module Temperature (oC) 49.2 49
Temperature Factor 0.9080 0.9088
System Losses (Cable, Inverter, Etc.) 0.95 0.95
String 1F:
Effiency Test 1st Run 2nd Run
Nominal Power 3270.00 3270.00
Solar Irradiance (W/m2) 858.00 851.00
Peak Sun Factor 0.86 0.85
Module Temperature (oC) 49.3 49.5
Temperature Factor 0.9077 0.9069
System Losses (Cable, Inverter, Etc.) 0.95 0.95
48.4
3rd Run
4905.00
800.00
0.80
48.1
0.9122
0.95
3400.57
3300.00
97.04%
90%
48.3
3rd Run
4905.00
785.00
0.79
47.7
0.9137
0.95
3342.37
3240.00
96.94%
90%
48.5
3rd Run
4905.00
831.00
0.83
48
0.9126
0.95
3533.82
3430.00
97.06%
90%
48.9
3rd Run
4905.00
837.00
0.84
49.1
0.9084
0.95
3543.03
3390.00
95.68%
90%
49.2
3rd Run
4905.00
850.00
0.85
49.2
0.9080
0.95
3596.55
3480.00
96.76%
90%
49.3
3rd Run
3270.00
862.00
0.86
49.6
0.9065
0.95
2427.48
2350.00
96.81%
90%
Other Info
Measurement
Tilt Angle 27.5o
Azimuth of 5o E of S
Note:
Peak Sun Factor = Measured Irradiance / 1000W/m2
Temperature Factor =
1+ [((Module Temperature Coefficient for Power)/100) x (Module Temperature in oC - 25)]