With reference to the flowmeters supplied against the referred LPO's, there is few
changes in model codes as mentioned below. These variations in model codes is the reflection of
upgrades to the ordered flowmeters.
Item Description Ordered Model Code Delivered Model Code List of Deviations
ABB WaterMaster FEF.121.999.K.1.S.1.S2. FEF.121.999.K.1.S.4.S2. A) Two Grounding ring
Electromagnetic Z.1.A.1.A.2.A.3.D.1.A.1 Z.1.A.1.A.5.A.3.D.1.A.1 added for enhanced
Flowmeter – .V0.CWA/SPX .V0.CWA/SPX performance.
50mmNB (2”) B A
B)The requested extra
cable length of 50 & 100
ABB WaterMaster FEF.121.100.K.1.S.1.S2. FEF.121.100.K.1.S.4.S2. meter is added.
Electromagnetic Z.1.A.1.A.2.A.3.D.1.A.1 Z.1.A.1.A.6.A.2.D.1.A.1
Flowmeter – .V0.CWA/SPX .V0.CWA/SPX C) Since the cable
100mmNB (4”) length is more for this
C
flowmeter, it is not
potted at factory. Will
be done at site.
Regards
Jamesh Babu M
Projects Engineer
Flowmeter Technical Services
+974-31341400
Page 1 of 1