Power Supply CBA Top View

CAUTION ! Because a hot chassis ground is present in the power supply


Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. CAUTION ! : For continued protection against risk of fire, NOTE: circuit, an isolation transformer must be used when repairing.
If Main Fuse (F1) is blown , check to see that all components in the power supply replace only with same type 5 A, 250V fuse. The voltage for parts in hot circuit is measured using Also, in order to have the ability to increase the input slowly,
circuit are not defective before you connect the AC plug to the AC power supply. 5A/250V ATTENTION : Utiliser un fusible de rechange de même type de 5A, 250V. when troubleshooting this type of power supply circuit,
hot GND as a common terminal.
Otherwise it may cause some components in the power supply circuit to fail. a variable isolation transformer is required.

10-19 DPS-40
Power Supply CBA Bottom View
CAUTION ! Because a hot chassis ground is present in the power supply
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. CAUTION ! : For continued protection against risk of fire, NOTE: circuit, an isolation transformer must be used when repairing.
If Main Fuse (F1) is blown , check to see that all components in the power supply replace only with same type 5 A, 250V fuse. The voltage for parts in hot circuit is measured using Also, in order to have the ability to increase the input slowly,
circuit are not defective before you connect the AC plug to the AC power supply. 5A/250V ATTENTION : Utiliser un fusible de rechange de même type de 5A, 250V. when troubleshooting this type of power supply circuit,
hot GND as a common terminal.
Otherwise it may cause some components in the power supply circuit to fail. a variable isolation transformer is required.

10-20 DPS-40
Power Supply Schematic Diagram
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
CAUTION ! : For continued protection against risk of fire, NOTE:
If Main Fuse (F1) is blown , check to see that all components in the power supply
replace only with same type 5 A, 250V fuse. The voltage for parts in hot circuit is measured using
circuit are not defective before you connect the AC plug to the AC power supply. 5A/250V ATTENTION : Utiliser un fusible de rechange de même type de 5A, 250V. hot GND as a common terminal.
Otherwise it may cause some components in the power supply circuit to fail.

10-16 PL10.4SCP