Anda di halaman 1dari 18

DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Analysis of reinforced slopes


Input data
Project
Task : JURAIN RAILWAY OVERBRIDGE
Part : DCL-CCECC-JV
Description : DESIGN AND ANALYSIS OF ABUTMENT WITH MECHANICALLY STABILIZED EARTH WALL
Customer : SWO-WEST/BANGLADESH ARMY
Author : PRIODEEP CHOWDHURY
Date : 7/9/2017
Project ID : #DCL-CCECC-JV
Project number : 001
Settings
USA - Safety factor
Materials and standards
Concrete structures : ACI 318-11
Wall analysis
Active earth pressure calculation : Coulomb
Passive earth pressure calculation : Mazindrani (Rankin)
Earthquake analysis : Mononobe-Okabe
Shape of earth wedge : Calculate as skew
Allowable eccentricity : 0.333
Internal stability : Standard - straight slip surface
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor for overturning : SFo = 1.50 [–]
Safety factor for sliding resistance : SFs = 1.50 [–]
Safety factor for bearing capacity : SFb = 2.00 [–]
Safety factor for sliding along geo-reinforcement : SFsr = 1.50 [–]
Safety factor for geo-reinforcement strength : SFst = 1.50 [–]
Safety factor for pull out resistance of geo-reinf. : SFpo = 1.50 [–]
Safety factor for connection strength : SFcon = 1.50 [–]
Stability analysis
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor : SFs = 1.50 [–]
Geometry of structure
Number of blocks n = 8
Block height h = 0.57 m
Block width b = 0.17 m
Block offset o1 = 0.02 m
Structure foundation
Foundation width bb = 0.51 m
Foundation height lb = 0.20 m
Foundation offset ab = 0.10 m
Material
Block material
Unit weight  = 25.00 kN/m3

DCL- A Member of DCL-CCECC JV 1


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Cohesion c = 0.00 kPa


Friction f = 0.533
Shear bearing capacity of joint Rs = 0.00 kN/m
Types of reinforcements
Type of
Name reinforcemen Line type Reinforcement strength Coefficient
No. t
Tult[kN/m] Rt[kN/m] Cds[–] Ci[–]
1 Miragrid 2XT Miragrid 2XT 29.20 7.37 0.80 0.80
Enkagrid PRO
2 Enkagrid PRO 60d 64.00 24.85 0.60 0.70
60d
Enkagrid PRO
3 Enkagrid PRO 90d 98.00 38.05 0.60 0.70
90d
Enkagrid PRO
4 Enkagrid PRO 120d 120.00 47.03 0.60 0.70
120d
Reinforcement details
1. Miragrid 2XT
Short-term char. strength Tult = 29.20 kN/m
Long-term design strength Rt = 7.37 kN/m
Overall coeff. of model uncertainty FSUNC = 1.50
Calculate reduction factors
Life time : 114 years
Creep red. factor RFCR = 1.60
Chemistry : pH 4.0-9.0
Durability red. factor RFD = 1.10
Partical size : D50  22 mm
Installation damage red. factor RFID = 1.50
2. Enkagrid PRO 60d
Short-term char. strength Tult = 64.00 kN/m
Long-term design strength Rt = 24.85 kN/m
Overall coeff. of model uncertainty FSUNC = 1.50
Calculate reduction factors
Life time : 120 years
Creep red. factor RFCR = 1.62
Chemistry : pH 4.0-9.0
Durability red. factor RFD = 1.00
Partical size : D90  35 mm
Installation damage red. factor RFID = 1.06
3. Enkagrid PRO 90d
Short-term char. strength Tult = 98.00 kN/m
Long-term design strength Rt = 38.05 kN/m
Overall coeff. of model uncertainty FSUNC = 1.50
Calculate reduction factors
Life time : 120 years
Creep red. factor RFCR = 1.62
Chemistry : pH 4.0-9.0
Durability red. factor RFD = 1.00
Partical size : D90  35 mm
Installation damage red. factor RFID = 1.06
4. Enkagrid PRO 120d
Short-term char. strength Tult = 120.00 kN/m

DCL- A Member of DCL-CCECC JV 2


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Long-term design strength Rt = 47.03 kN/m


Overall coeff. of model uncertainty FSUNC = 1.50
Calculate reduction factors
Life time : 120 years
Creep red. factor RFCR = 1.62
Chemistry : pH 4.0-9.0
Durability red. factor RFD = 1.00
Partical size : D90  35 mm
Installation damage red. factor RFID = 1.05
Reinforcement
Total number of inputted reinforcements : 8.

Reinforcement details
Block Type of reinforcement Origin End Height from bottom Length
No. l1[m] l2[m] h[m] l[m]
1 Enkagrid PRO 120d -0.14 3.86 0.00 4.00
2 Enkagrid PRO 120d -0.12 3.88 0.57 4.00
3 Enkagrid PRO 120d -0.10 3.90 1.14 4.00
4 Enkagrid PRO 120d -0.08 3.92 1.71 4.00
5 Enkagrid PRO 120d -0.06 3.94 2.28 4.00
6 Enkagrid PRO 120d -0.04 3.96 2.85 4.00
7 Enkagrid PRO 90d -0.02 3.98 3.42 4.00
8 Enkagrid PRO 90d 0.00 4.00 3.99 4.00
Soil parameters
Sand with trace of fines (S-F), dense
Unit weight :  = 18.00 kN/m3
Angle of internal friction : ef = 30.00 °
Cohesion of soil : cef = 0.00 kPa
Angle of friction struc.-soil :  = 18.00 °
Saturated unit weight : sat = 20.00 kN/m3

Low plasticity silt (ML,MI), consistency firm


Unit weight :  = 20.00 kN/m3
Angle of internal friction : ef = 21.00 °
Cohesion of soil : cef = 12.00 kPa
Angle of friction struc.-soil :  = 18.00 °
Saturated unit weight : sat = 20.00 kN/m3

Geological profile and assigned soils


Layer
No. Assigned soil Pattern
[m]

1 4.50 Sand with trace of fines (S-F), dense

2 10.50 Low plasticity silt (ML,MI), consistency firm

3 - Sand with trace of fines (S-F), dense

Terrain profile
Terrain behind the structure is flat.

DCL- A Member of DCL-CCECC JV 3


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Water influence
Ground water table is located below the structure.

Input surface surcharges


Surcharge Mag.1 Mag.2 Ord.x Length Depth
No. Action
new change [kN/m2] [kN/m2] x [m] l [m] z [m]
1 YES permanent 30.00 on terrain
No. Name
1 Surcharge
Resistance on front face of the structure
Resistance on front face of the structure is not considered.

Settings of the stage of construction


Design situation : permanent

Verification No. 1
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 0.57 0.00 30.00 0.00 18.00 30.00 0.297
2 0.57 -2.01 30.00 0.00 18.00 30.00 0.282
3 0.57 -2.01 30.00 0.00 18.00 30.00 0.282
4 0.57 -2.01 30.00 0.00 18.00 30.00 0.282
5 0.57 -2.01 30.00 0.00 18.00 30.00 0.282
6 0.57 -2.01 30.00 0.00 18.00 30.00 0.282
7 0.57 -2.01 30.00 0.00 18.00 30.00 0.282
8 0.51 -2.01 30.00 0.00 18.00 30.00 0.282
9 0.06 -2.01 21.00 12.00 20.00 21.00 0.397
10 0.20 0.00 21.00 12.00 20.00 21.00 0.411
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
0.57 10.26 0.00 3.05 2.64 1.52
0.57 10.26 0.00 2.89 2.55 1.36
2
1.14 20.52 0.00 5.79 5.11 2.72
1.14 20.52 0.00 5.79 5.11 2.72
3
1.71 30.78 0.00 8.68 7.66 4.07
1.71 30.78 0.00 8.68 7.66 4.07
4
2.28 41.04 0.00 11.57 10.22 5.43
2.28 41.04 0.00 11.57 10.22 5.43
5
2.85 51.30 0.00 14.46 12.77 6.79
2.85 51.30 0.00 14.46 12.77 6.79
6
3.42 61.56 0.00 17.36 15.33 8.15
3.42 61.56 0.00 17.36 15.33 8.15
7
3.99 71.82 0.00 20.25 17.88 9.50
3.99 71.82 0.00 20.25 17.88 9.50
8
4.50 81.00 0.00 22.84 20.17 10.72

DCL- A Member of DCL-CCECC JV 4


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Layer Start [m] Z W Pressure Hor. comp. Vert. comp.


No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
4.50 81.00 0.00 18.49 17.49 6.02
9
4.56 82.20 0.00 18.97 17.94 6.17
4.56 82.20 0.00 20.38 19.02 7.30
10
4.76 86.20 0.00 22.02 20.56 7.89
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Gravity force 0.00 -2.46 331.56 2.33 1.000
Active pressure 50.42 -1.60 26.05 4.10 1.000
Surcharge 36.73 -2.32 19.26 4.17 1.000
Weight - wall 0.00 -2.48 19.38 0.26 1.000
Surcharge 0.00 -4.76 120.00 2.41 1.000
Verification of complete wall
Check for overturning stability
Resisting moment Mres = 1254.35 kNm/m
Overturning moment Movr = 165.99 kNm/m

Safety factor = 7.56 > 1.50


Wall for overturning is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 204.29 kN/m
Active horizontal force Hact = 87.15 kN/m

Safety factor = 2.34 > 1.50


Wall for slip is SATISFACTORY

Overall check - WALL is SATISFACTORY

Dimensioning No. 1
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 0.57 0.00 30.00 0.00 18.00 18.00 0.299
2 0.57 0.00 30.00 0.00 18.00 18.00 0.299
3 0.57 0.00 30.00 0.00 18.00 18.00 0.299
4 0.57 0.00 30.00 0.00 18.00 18.00 0.299
5 0.57 0.00 30.00 0.00 18.00 18.00 0.299
6 0.57 0.00 30.00 0.00 18.00 18.00 0.299
7 0.57 0.00 30.00 0.00 18.00 18.00 0.299
8 0.16 0.00 30.00 0.00 18.00 18.00 0.299
9 0.35 30.50 30.00 0.00 18.00 30.00 0.677
10 0.06 30.50 21.00 12.00 20.00 21.00 0.756
11 0.20 0.00 21.00 12.00 20.00 18.00 0.414

DCL- A Member of DCL-CCECC JV 5


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Active pressure distribution behind the structure (without surcharge)


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
0.57 10.26 0.00 3.06 2.91 0.95
0.57 10.26 0.00 3.06 2.91 0.95
2
1.14 20.52 0.00 6.13 5.83 1.89
1.14 20.52 0.00 6.13 5.83 1.89
3
1.71 30.78 0.00 9.19 8.74 2.84
1.71 30.78 0.00 9.19 8.74 2.84
4
2.28 41.04 0.00 12.26 11.66 3.79
2.28 41.04 0.00 12.26 11.66 3.79
5
2.85 51.30 0.00 15.32 14.57 4.73
2.85 51.30 0.00 15.32 14.57 4.73
6
3.42 61.56 0.00 18.38 17.48 5.68
3.42 61.56 0.00 18.38 17.48 5.68
7
3.99 71.82 0.00 21.45 20.40 6.63
3.99 71.82 0.00 21.45 20.40 6.63
8
4.15 74.74 0.00 22.32 21.23 6.90
4.15 74.74 0.00 50.58 24.91 44.02
9
4.50 81.00 0.00 54.81 27.00 47.71
4.50 81.00 0.00 49.76 30.98 38.94
10
4.56 82.20 0.00 50.66 31.54 39.65
4.56 82.20 0.00 20.32 19.32 6.28
11
4.76 86.20 0.00 21.98 20.90 6.79
Pressure profile due to surcharge - Surcharge
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 8.52 2.77
2 0.57 8.52 2.77
3 0.57 0.00 0.00
4 0.57 0.00 0.00
5 0.57 8.52 2.77
6 1.14 8.52 2.77
7 1.14 0.00 0.00
8 1.14 0.00 0.00
9 1.14 8.52 2.77
10 1.71 8.52 2.77
11 1.71 0.00 0.00
12 1.71 0.00 0.00
13 1.71 8.52 2.77
14 2.28 8.52 2.77
15 2.28 0.00 0.00
16 2.28 0.00 0.00
17 2.28 8.52 2.77
18 2.85 8.52 2.77
19 2.85 0.00 0.00
20 2.85 0.00 0.00

DCL- A Member of DCL-CCECC JV 6


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
21 2.85 8.52 2.77
22 3.42 8.52 2.77
23 3.42 0.00 0.00
24 3.42 0.00 0.00
25 3.42 8.52 2.77
26 3.99 8.52 2.77
27 3.99 0.00 0.00
28 3.99 0.00 0.00
29 3.99 8.52 2.77
30 4.15 8.52 2.77
31 4.15 10.00 17.67
32 4.50 10.00 17.67
33 4.50 14.12 17.75
34 4.56 14.12 17.75
35 4.56 11.83 3.84
36 4.76 11.83 3.84
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -2.48 19.38 0.26 1.000
Weight - earth wedge 0.00 -0.33 0.91 0.35 1.000
Active pressure 58.99 -1.57 33.92 0.37 1.000
Surcharge 42.06 -2.30 19.47 0.37 1.000
Reinforcement -47.03 -0.20 0.00 0.37 1.000
Reinforcement -47.03 -0.77 0.00 0.75 1.000
Reinforcement -47.03 -1.34 0.00 1.12 1.000
Reinforcement -47.03 -1.91 0.00 1.50 1.000
Reinforcement -47.03 -2.48 0.00 1.88 1.000
Reinforcement -47.03 -3.05 0.00 2.26 1.000
Reinforcement -29.13 -3.62 0.00 2.63 1.000
Reinforcement -11.60 -4.19 0.00 3.01 1.000
Verification of complete wall
Check for overturning stability
Resisting moment Mres = 637.49 kNm/m
Overturning moment Movr = 189.37 kNm/m

Safety factor = 3.37 > 1.50


Wall for overturning is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 357.33 kN/m
Active horizontal force Hact = 101.05 kN/m

Safety factor = 3.54 > 1.50


Wall for slip is SATISFACTORY

Overall check - WALL is SATISFACTORY

DCL- A Member of DCL-CCECC JV 7


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Bearing capacity of foundation soil


Design load acting at the center of footing bottom
Moment Norm. force Shear Force Eccentricity Stress
No.
[kNm/m] [kN/m] [kN/m] [–] [kPa]
1 -429.33 73.68 -221.87 0.000 144.47
Service load acting at the center of footing bottom
Moment Norm. force Shear Force
No.
[kNm/m] [kN/m] [kN/m]
1 -429.33 73.68 -221.87
Verification of foundation soil
Eccentricity verification
Max. eccentricity of normal force e = 0.000
Maximum allowable eccentricity ealw = 0.333
Eccentricity of the normal force is SATISFACTORY

Verification of bearing capacity


Max. stress at footing bottom  = 144.47 kPa
Bearing capacity of foundation soil Rd = 300.00 kPa
Safety factor = 2.08 > 2.00
Bearing capacity of foundation soil is SATISFACTORY

Overall verification - bearing capacity of found. soil is SATISFACTORY

Verification of slip on georeinforcement No. 1


Forces acting on construction (verification of most utilized reinforcement)
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -2.28 19.38 -0.02 1.000
Active pressure 46.44 -1.52 24.50 4.05 1.000
Surcharge 34.29 -2.27 18.11 4.08 1.000
Gravity force 0.00 -2.28 329.59 2.07 1.000
Surcharge 0.00 -4.56 120.58 2.15 1.000
Reinforcement -0.01 -0.57 0.00 4.02 1.000
Reinforcement -0.01 -1.14 0.00 4.04 1.000
Reinforcement -0.01 -1.71 0.00 4.06 1.000
Reinforcement -0.01 -2.28 0.00 4.08 1.000
Reinforcement -0.01 -2.85 0.00 4.10 1.000
Reinforcement -0.01 -3.42 0.00 4.12 1.000
Reinforcement -0.01 -3.99 0.00 4.14 1.000
Check for slip along geo-reinforcement with the maximal utilization (Reinforc. No.: 1)
Inclination of slip surface = 88.00 °
Overall normal force acting on reinforcement = 492.77 kN/m
Coefficient of reduction of slip along = 0.60
geo-textile
Wall resistance = 10.33 kN/m
Overall bearing capacity of reinforcements = 0.07 kN/m
Resistance along geo-reinforcement = 113.49 kN/m

Check for slip:


Resisting horizontal force Hres = 123.89 kN/m

DCL- A Member of DCL-CCECC JV 8


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Active horiz. force Hact = 80.74 kN/m


Factor of safety = 1.53 > 1.50
Slip along geotextile is SATISFACTORY

Calculation of internal stability No. 1


Calculated forces and strength of geo-reinforcements
Name Fx Depth Rt Utilization Tp Utilization
No.
[kN/m] z[m] [kN/m] [%] [kN/m] [%]
1 Enkagrid PRO 120d -8.82 4.56 47.03 28.13 176.70 7.49
2 Enkagrid PRO 120d -16.19 3.99 47.03 51.64 213.43 11.38
3 Enkagrid PRO 120d -14.28 3.42 47.03 45.55 166.85 12.84
4 Enkagrid PRO 120d -12.68 2.85 47.03 40.45 125.64 15.14
5 Enkagrid PRO 120d -11.08 2.28 47.03 35.34 89.78 18.51
6 Enkagrid PRO 120d -9.48 1.71 47.03 30.24 59.29 23.99
7 Enkagrid PRO 90d -7.88 1.14 38.05 31.07 34.16 34.60
8 Enkagrid PRO 90d -8.82 0.57 38.05 34.77 14.40 91.87
Check for tensile strength (georeinforcement No.2)
Tensile strength Rt = 47.03 kN/m
Geo-reinforcement force Fx = 16.19 kN/m
Factor of safety = 2.90 > 1.50
Geo-reinforcement for tensile strength is SATISFACTORY

Check for pull out resistance (georeinforcement No.8)


Pull out resistance Tp = 14.40 kN/m
Geo-reinforcement force Fx = 8.82 kN/m
Factor of safety = 1.63 > 1.50
Geo-reinforcement for pull out resistance is SATISFACTORY

Overall verification - geo-reinforcement is SATISFACTORY

Global stability analysis No. 1


Slip surface parameters
(analysis without slip surface optimization)
Center S = (-1.30;-0.06) m
Radius r = 5.14 m
Angle 1 = -20.32 °
2 = 89.33 °
Slope stability check (Spencer)
FS = 3.99 > 1.50
Slope stability is SATISFACTORY
Solution was found for reduction of forces in reinforcements 90.23 %.
Slope stability analysis
Input data
Project
Settings
USA - Safety factor
Stability analysis
Earthquake analysis : Standard
Verification methodology : Safety factors (ASD)

DCL- A Member of DCL-CCECC JV 9


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Safety factors
Permanent design situation
Safety factor : SFs = 1.50 [–]
Interface
Coordinates of interface points [m]
No. Interface location
x z x z x z
1 -0.29 -3.99 -0.14 -3.99 -0.12 -3.99
-0.12 -3.42 -0.10 -3.42 -0.10 -2.85
-0.08 -2.85 -0.08 -2.28 -0.06 -2.28
-0.06 -1.71 -0.04 -1.71 -0.04 -1.14
-0.02 -1.14 -0.02 -0.57 0.00 -0.57
0.00 0.00

2 -11.90 -4.76 -0.41 -4.76 -0.41 -4.56


-0.31 -4.56 -0.31 -3.99 -0.29 -3.99
-0.29 -3.42 -0.27 -3.42 -0.27 -2.85
-0.25 -2.85 -0.25 -2.28 -0.23 -2.28
-0.23 -1.71 -0.21 -1.71 -0.21 -1.14
-0.19 -1.14 -0.19 -0.57 -0.17 -0.57
-0.17 0.00 0.00 0.00 14.28 0.00

3 -0.14 -3.99 -0.14 -4.50 14.28 -4.50

4 -0.14 -4.50 -0.14 -4.56 0.10 -4.56

5 -0.41 -4.76 0.10 -4.76 0.10 -4.56


14.28 -4.56

6 -11.90 -15.00 14.28 -15.00

DCL- A Member of DCL-CCECC JV 10


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Soil parameters - effective stress state


ef cef 
No. Name Pattern
[°] [kPa] [kN/m3]

1 Sand with trace of fines (S-F), dense 30.00 0.00 18.00

2 Low plasticity silt (ML,MI), consistency firm 21.00 12.00 20.00

Soil parameters - uplift


sat s n
No. Name Pattern
[kN/m3] [kN/m3] [–]

1 Sand with trace of fines (S-F), dense 20.00

2 Low plasticity silt (ML,MI), consistency firm 20.00

Soil parameters
Sand with trace of fines (S-F), dense
Unit weight :  = 18.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 30.00 °
Cohesion of soil : cef = 0.00 kPa
Saturated unit weight : sat = 20.00 kN/m3

Low plasticity silt (ML,MI), consistency firm


Unit weight :  = 20.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 21.00 °
Cohesion of soil : cef = 12.00 kPa
Saturated unit weight : sat = 20.00 kN/m3

Rigid bodies

No. Name Sample
[kN/m3]

1 Wall material 25.00

DCL- A Member of DCL-CCECC JV 11


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Assigning and surfaces


Coordinates of surface points [m] Assigned
No. Surface position
x z x Z soil
1 -0.17 0.00 -0.17 -0.57
Wall material
-0.19 -0.57 -0.19 -1.14
-0.21 -1.14 -0.21 -1.71
-0.23 -1.71 -0.23 -2.28
-0.25 -2.28 -0.25 -2.85
-0.27 -2.85 -0.27 -3.42
-0.29 -3.42 -0.29 -3.99
-0.14 -3.99 -0.12 -3.99
-0.12 -3.42 -0.10 -3.42
-0.10 -2.85 -0.08 -2.85
-0.08 -2.28 -0.06 -2.28
-0.06 -1.71 -0.04 -1.71
-0.04 -1.14 -0.02 -1.14
-0.02 -0.57 0.00 -0.57
0.00 0.00

2 -0.14 -4.50 14.28 -4.50 Sand with trace of fines


14.28 0.00 0.00 0.00 (S-F), dense
0.00 -0.57 -0.02 -0.57
-0.02 -1.14 -0.04 -1.14
-0.04 -1.71 -0.06 -1.71
-0.06 -2.28 -0.08 -2.28
-0.08 -2.85 -0.10 -2.85
-0.10 -3.42 -0.12 -3.42
-0.12 -3.99 -0.14 -3.99

3 14.28 -4.56 14.28 -4.50 Low plasticity silt (ML,MI),


-0.14 -4.50 -0.14 -4.56 consistency firm
0.10 -4.56

4 0.10 -4.76 0.10 -4.56


Wall material
-0.14 -4.56 -0.14 -4.50
-0.14 -3.99 -0.29 -3.99
-0.31 -3.99 -0.31 -4.56
-0.41 -4.56 -0.41 -4.76

DCL- A Member of DCL-CCECC JV 12


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Coordinates of surface points [m] Assigned


No. Surface position
x z x Z soil
5 14.28 -15.00 14.28 -4.56 Low plasticity silt (ML,MI),
0.10 -4.56 0.10 -4.76 consistency firm
-0.41 -4.76 -11.90 -4.76
-11.90 -15.00

6 -11.90 -15.00 -11.90 -20.00 Sand with trace of fines


14.28 -20.00 14.28 -15.00 (S-F), dense

Reinforcements
Point to the left Point to the right Length Strength End of
No. Pull out resist.
x [m] z [m] x [m] z [m] L [m] Rt [kN/m] reinf.
1 0.00 -0.57 4.00 -0.57 4.00 38.05 Tp = 11.85 kN/m2 Fixed
2 -0.02 -1.14 3.98 -1.14 4.00 38.05 Tp = 23.69 kN/m2 Fixed
3 -0.04 -1.71 3.96 -1.71 4.00 47.03 Tp = 35.54 kN/m2 Fixed
4 -0.06 -2.28 3.94 -2.28 4.00 47.03 Tp = 47.39 kN/m2 Fixed
5 -0.08 -2.85 3.92 -2.85 4.00 47.03 Tp = 59.24 kN/m2 Fixed
6 -0.10 -3.42 3.90 -3.42 4.00 47.03 Tp = 71.08 kN/m2 Fixed
7 -0.12 -3.99 3.88 -3.99 4.00 47.03 Tp = 82.93 kN/m2 Fixed
8 -0.14 -4.56 3.86 -4.56 4.00 47.03 Tp = 63.11 kN/m2 Fixed

Surcharge
Location Origin Length Width Slope Magnitude
No. Type Type of action
z [m] x [m] l [m] b [m]  [°] q, q1, f, F q2 unit
1 strip permanent on terrain x = 0.00 l = 14.28 0.00 30.00 kN/m2
Surcharges

No. Name

1 Surcharge
Water
Water type : No water
Tensile crack
Tensile crack not inputted.
Earthquake
Earthquake not included.
Settings of the stage of construction
Design situation : permanent

DCL- A Member of DCL-CCECC JV 13


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
DCL DESIGN & ANALYSIS OF MSE WALL

(A MEMBER OF DCL-CCECC JV) ANALYSED BY: PRIODEEP CHOWDHURY

Results (Stage of construction 1)


Analysis 1
Circular slip surface
Slip surface parameters
x= -0.40 [m] 1 = -32.20 [°]
Center : Angles :
z= 1.95 [m] 2 = 75.76 [°]
Radius : R= 7.93 [m]
Analysis of the slip surface without optimization.
Reinforcement forces
Reinforcement Force [kN/m]
1 0.00
2 0.00
3 0.00
4 0.00
5 0.00
6 0.00
7 0.00
8 0.00
Slope stability verification (Spencer)
Factor of safety = 1.50 > 1.50
Slope stability ACCEPTABLE

DCL- A Member of DCL-CCECC JV 14


[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
JURAIN RAILWAY OVERBRIDGE
PRIODEEP CHOWDHURY DCL-CCECC-JV

Name : Stage : 1

Sand with trace of fines (S-F), dense Low plasticity silt (ML,MI), consistency firm

[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
JURAIN RAILWAY OVERBRIDGE
PRIODEEP CHOWDHURY ANALYSIS FOR GLOBAL STABILITY DCL-CCECC-JV

Name : Stage - analysis : 1 - 1

(-1.30;-0.06) +x
8

+z
6

Sand with trace of fines (S-F), dense Low plasticity silt (ML,MI), consistency firm

[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
JURAIN RAILWAY OVERBRIDGE
PRIODEEP CHOWDHURY ANALYSIS FOR SLOPE STABILITY DCL-CCECC-JV

Name : Stage - analysis : 1 - 1

Wall material Sand with trace of fines (S-F), dense

Low plasticity silt (ML,MI), consistency firm

Analysis of the slip surface without optimization.


Slope stability verification (Fellenius / Petterson)
Sum of active forces : Fa = 212.48 kN/m
Sum of passive forces : Fp = 516.70 kN/m
Sliding moment : Ma = 1238.77 kNm/m
Resisting moment : Mp = 3012.37 kNm/m
Factor of safety = 2.43 > 1.50
Slope stability ACCEPTABLE

[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
JURAIN RAILWAY OVERBRIDGE
PRIODEEP CHOWDHURY ANALYSIS FOR SLIP STABILITY DCL-CCECC-JV

Name : Stage - analysis : 1 - 1

120.58

8
0.01
7
329.59 0.01
6
19.38 0.01
5 38.78
0.01
4
0.01 52.51
3
0.01
2
0.01
1
+x

+z

Sand with trace of fines (S-F), dense Low plasticity silt (ML,MI), consistency firm

[GeoStructural Analysis - MSE Wall | version 5.19.5.0 | Copyright © 2015 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]

Anda mungkin juga menyukai