friendly
For high temperature AQYLON’s ORC modules are AQYLON’s ORC modules apply
applications, AQYLON’s organic designed for durability and fit into cutting edge technology
working fluids have a very low standard containers, allowing for to maximize efficiency according
Global Warming Potential modular deployment. to the heat source. AQYLON
(GWP 3-20). holds four patents related to
turbines and ORC technology,
and eight more are pending.
Electrical network
or factory grid
AQYLON ORC
module
ORC module
Parameters Unit
ATM-1000H ATM-3000H ATM-5000H
Gross electrical production (with nominal heat values), up to kWe 1230 3655 6081
kWe
Electrical Power
Net electrical production (with nominal heat values), up to 1160 3475 5791
Self comsumption % 5,7% 4,9% 4,7%
H range - High temperature range - 260°C to 330°C
Inlet temperature of thermal oil (to get nominal power production) °C 305 305 305
Outlet temperature of thermal oil (back to exchanger) °C 205 205 205
Thermal oil flow rate kg/s 21 61 101
Thermal power available on the cold circuit (maximum supplied) kWth 3850 11585 19319
Inlet temperature of cooling water (to get nominal power production) °C 35 35 35
Outlet temperature on the cold circuit (to get nominal power production) °C 45 45 45
Cooling water flow rate kg/s 91.6 276 460
Organic fluid - (MM) Hexamethyldisiloxane (MM) Hexamethyldisiloxane (MM) Hexamethyldisiloxane
Quantity of organic fluid in the module t <2 <6 < 10
ORC hot circuit flanges - DN150 PN16 DN150 PN16 DN150 PN16
ORC cold circuit flanges - DN250 PN16 DN250 PN16 DN250 PN16
ORC dimensions (HxWxD) m3 6,5 x 12,2 x 2,5 6,5 x 12,2 x 10 6,5 x 12,2 x 15
ORC weight t 54 188 322
Coolers dimensions (HxWxD) m3 6 x 11 x 6 6 x 11 x 18 6 x 11 x 30
Coolers weight t 10 30 50
In the figure above we can see a heat exchanger with its bypass,
placed on the fumes of glass factory. The heat is sent to the ORC
through a thermal oil loop. Dry coolers are used for the cold loop
of the ORC.
AQYLON offers two business models. Customers may invest through the usual product purchasing process. For customers not
willing to invest, we have a “ZERO CAPEX/ OPEX” option with turnkey solutions fully financed with the sale of the produced electricity,
at a lower price than the grid (PPA).