Anda di halaman 1dari 1

Hollister-Whitney rope gripper

Maintenance Guideline

Symptoms Possible causes Action


Pump does not stop and Brake ready microswitch Connect multimeter probes to
solenoid does not trigger in contact does not open. RG1 and RG4. Check
primed position. adjustment of contact.
Replace the faulty switches.
Refer to AS-04.08.090.

© 2006 KONE Corporation ASG-04.08.090


All rights reserved. 17 (18) (-) 2006-03-02