Anda di halaman 1dari 16

NEC PASOLINK NEO Microwave

Acceptance Test Record


(V1.0)

Contract Number __________________


Project Name __________________
User __________________
Acceptance Date __________________

ZTE CORPORATION
Legal Information

All rights reserved. No part of this documentation may be excerpted,


reproduced, translated, annotated or duplicated, in any form or by any means
without the prior written permission of ZTE Corporation.

and
are the

registered trade marks of ZTE Corporation. The names and logos of ZTE
products are proprietary logos or registered trade marks. The names of other
products and companies mentioned in this manual may be proprietary to their
owners respectively. Without the prior written permission of ZTE or the owners
of third-party trade marks or trade names, this manual does not grant the
reader any permission or right to use any marker appeared in the manual.

The product described herein conforms to the design requirements of


environment protection and human security. The storage, usage, and discard
of the product shall comply with the manual, related contract, or laws and
regulations of related countries.

The actual product may differ from what is described in this standard due to
frequent update of ZTE products and fast development of technologies. Please
contact the local ZTE office for the latest updating information of the product.
For the latest document information, please visit our website:
http://tsm.zte.com.cn
Feedback Table

You are invited to give your suggestions and opinions to improve ZTE user manuals and enjoy better
service by sending emails to yddoc@zte.com.cn. Thank you for your cooperation!

Document Name NEC PAS0LINK NEO Microwave Test Record (V1.0)


Product Version Document Version
NEO V1.0
No. No.
Please provide your information for further contact:
Compan
Name
y
Post Code Address
Tel E-mail
Very
Good Ordinary Bad Very Bad
Good
General View
Maneuverability
Installation environment
Equipment installation
Cable layout
Layout of cable troughs
Cable specifications
Grounding system
Outlook and assembly
Comments Labeling requirements
Correct content
Complete content
You may give suggestions
from any perspective such
as the content, structure,
details, depth, expression,
figures/tables, special tools,
FAQ and so on. The
suggestions are not
confined to this document.

Suggestions
Revision Records
Document Prepared/ Prepared/Revi Reason for Contents of Revision
Total Pages
Version No. Revised by sed on Revision (Key Points Only)
The first
V1.0 He Li 2009-09-17 None
issue

Note 1: This table must be completed before updating the archived document (the document archived in the
archival room of the division or the Company).
Note 2: Fill "None" in "Reason for Revision" and "Contents of Revision" when archiving this document for
the first time.
NEC PASOLINK NEO Microwave Acceptance Test Record

1 Participants in Acceptance Test:

Customer Project name

Date of
Date of
commenceme
completion
nt
Person in charge:

Customer’s Participants:
personnel

Person in charge:

ZTE’s Participants:
personnel

Person in charge:

Project
supervisor’s Participants:
personnel

3
NEC PASOLINK NEO Microwave Acceptance Test Record

Constructor’s Person in charge:


personnel

Participants:

Remarks

4
NEC PASOLINK NEO Microwave Acceptance Test Record

2 XX Test Record

Note: This test record lists all possible test items of the whole project. You
need to select from these test items to suit specific device functionality and
project category (new, expansion or reform) of a contract.

2.1 Site Information


Site ID:
Site Name:
Date of Check:
Subcontractor:
Opposite ID:
Opposite Name:

2.2 Configuration Check


Configuration □ 1 + 0 | □ 1 + 1 HSB | □ 1 + 1 SD
Freq. band GHz | Sub-band:
Hardware Capacity 5E1 | □ 5/10/16E1 | □ STM-1

2.3 Serial number Information


Equipment Qty Type Serial Number ch.1 Serial Number ch.2
IDU
ODU
Antenna

Type for IDU: 1+1 HSB/ 1+0/ ; STM1 OPT/ELECT or 5/10/16/40/48E1 or LAN INTFC

5
NEC PASOLINK NEO Microwave Acceptance Test Record

ODU: NEO 7/11/13/15GHz

Antenna: SP 7/11/13/15GHz or DP 7/11/13/15GHz

2.4 Antenna Information


Antenna
- Diameter [Main] ________ (M), [SD] ________ (M)
- Heights [Main] ________ (M), [SD] ________ (M)
- Polarization: □ Vertical □ Horizontal

2.5 Installation Check List


Note: Severity levels can be classified according to actual status on site. Level 1 is the
most serious and Level 4 is the small problem. The following table is just a reference
for severity classification.

Severity
NO. Check Item Points of Check OK NOK Remark
Level

1.Indoor Installation

The positions and heights of wiring racks meet the


1.1 Wiring rack installation 3
requirements of project design.
All wiring racks are well grounded. The electric
characters of all joints are good, and their
1.2 Wiring rack installation 2
connections with the main grounding point in the
host room are sound.
DDF/ Distributing The positions of distributing frames meet the
1.3 3
frames installation requirements of project installation.
Distributing frames shall be connected to the
DDF/ Distributing protection grounding point in the host room not
1.4 4
frames installation less 16 mm2 (or above) grounding wires, and the
connecting points shall be well contacted.

6
NEC PASOLINK NEO Microwave Acceptance Test Record

NO. Check Item Severity Points of Check OK NOK Remark


Level
NEC PASOLINK NEO The verticality of Racks shall meet the
1.5 4
IDU Rack installation requirements with a deviation less than 2mm-3mm.

NEC PASOLINK NEO The Racks are fixed in accordance with the
1.6 4
IDU Rack installation installation requirements, which shall be firm.
NEC PASOLINK NEO’s modules or cards should
NEC PASOLINK NEO
1.7 2 be correctly mounted, and have no damages. These
IDU Installation
modules or cards should be well fixed by bolts.
The ground wiring in equipment room shall meet
1.8 2
the requirements of project design.

Both work ground and protection ground shall use


Checking grounding
1.9 2 wires of a whole piece, yellow-green wires over
system
16mm2 long. Multiple connections are not allowed.

Each ground line from the grounding bus is


1.10 3
connected with only one set of equipment.
Tight and reliable contact with IDU; good electric
1.11 2
IF cable indoor performance.
installation Lines shall be straight without obvious undulation
1.12 4
or skewness, and also without crossover.

Lines shall be straight without obvious undulation


1.13 2M line layout 3
or skewness, and also without crossover

The cables shall be connected to the right positions


1.14 2M line layout 3
tightly. Good electric performance.
Power line installation The DC power supply is connected to the power
1.15 3 terminal on a rack, with the anode and cathode
connected correctly.
1.16 3 The specifications of power lines shall be in
compliance with design requirements, straightly
laid with sound connection.

7
NEC PASOLINK NEO Microwave Acceptance Test Record

NO. Check Item Severity Points of Check OK NOK Remark


Level
The copper lugs of power lines shall be firm and
1.17 3
upright.

1.18 2 Power lines and signal lines shall be separated.

E1 lines, power lines and IF cables are all correctly


1.19 3
labeled.

2.Outdoor Installation

2.1 ODU installation 2 ODU installation position complies with project


design requirements. Its direction of polarization is
cons
ODU fixing complies with installation
2.2 ODU installation 2
requirements. The fasteners are firm
When ODU can not be connected with antennas
2.3 ODU installation 2
directly.
2.4 Outdoor wiring racks 4 Outdoor wiring racks are installed between
equipment room and antenna pole (or iron tower).
Anti-oxidization measure is made to the wiring rac
The joint of the feed line and ODU connector shall
2.5 2
be in good contact.
2.6 IF cable outdoor 3 The routing of feed lines shall be tidy without
installation crossover, twist or damage. Use a fastener to fasten
the lines every .1.0m-1.5m.

2.7 3 Attach labels to each of the feeder connectors.

2.8 Antenna installation 3 Antenna must be stable and firm


2.9 Antenna installation 2 The spacing of antennas and that of diversity
reception shall meet the requirements of project
design.
The antenna shall be installed within the protection
2.10 Antenna installation 3
range of the lightning rod.

8
NEC PASOLINK NEO Microwave Acceptance Test Record

NO. Check Item Severity Points of Check OK NOK Remark


Level
The cross arm structure of the iron pole on the iron
Antenna supporting
2.11 3 tower and the antenna-supporting pole shall be
parts
firm, installed stably.
Verify the antenna is single-polarized or dual-
2.12 Antenna polarity mode 3
polarized in polarity mode.
Verify the antenna is horizontal-polarized or
Polarity direction of
vertical-polarized in
2.13 single-polarized 2
polarity direction.
antenna
(Do not apply to dual-polarized antenna.)
Record antenna diameter and frequency, at the
same time, verify whether they are meet design
Antenna diameter and
2.14 3 requirements.
frequency
For dual-polarized antenna, record the frequency of
each polarity direction

3.Other Installation

3.1 DC power supply test 2 DC voltage is within the range of -40.5 V to -57 V.

Hardware damaged or
3.2 2 All hardware equipments and modules are in good
not

3.3 Cables connection 2 All cables are connected correctly.

4. Test Record

4.1 Power Supply Test 2 IDU DC power test

Test operation &


4.2 1 Parameter setting function
maintenance functions
Test operation &
4.3 2 System monitoring functions
maintenance functions
Test operation & Alarm query function and IDU front panel
4.4 2
maintenance functions indicator alarm test

9
NEC PASOLINK NEO Microwave Acceptance Test Record

NO. Check Item Severity Points of Check OK NOK Remark


Level
4.5

Test operation &


2 User management function
maintenance functions

4.6

Test operation &


3 Log query function
maintenance functions

Test operation &


4.7 3 Self-loop test function
maintenance functions

4.8 System function test 1 1+1 protection auto switchover

System performance
4.9 1 Transmission power test
test
System performance
4.10 1 Receiving signal level test
test
System performance
4.11 3 Transmission frequency record
test

10
NEC PASOLINK NEO Microwave Acceptance Test Record

NO. Check Item Severity Points of Check OK NOK Remark


Level
4.12

System performance
3 Receiving frequency record
test

11
NEC PASOLINK NEO Microwave Acceptance Test Record

3 Conclusion

Customer’s
comments

Signature: Date:

ZTE’s
comments

Signature: Date:

Project
supervisor’s
comments

13
NEC PASOLINK NEO Microwave Acceptance Test Record

Signature: Date:

Constructor’s

Signature: Date:

comments

14