∑ Fy = 0
RA + RB − F = 0
RA + RB = 39.2
RA = 18.96N
∑ MA = 0
RB × 241.7 − 39.2 × 124.8 = 0
RB = 20.24 N
RA
∑ Mo = 0
−18.96x + M = 0
M = 18.96x
M(0) = 0
M(124.8) = 2.366Nm
M(120.8) = 2.29Nm (Momento flector)
Fibras a compresión:
−𝑀𝑦
𝜎=
𝐼
𝑏ℎ³
𝐼=
12
0.2417 ∗ (0.0054)³
𝐼=
12
𝐼 = 3.17 ∗ 10−9
−2.29 ∗ 0.2555
𝜎=
3.17 ∗ 10−9
𝜎 = −184.5𝑀𝑃𝑎
Fibras a tracción:
𝑀𝑦
𝜎=
𝐼
𝑏ℎ³
𝐼=
12
0.2417 ∗ (0.0054)³
𝐼=
12
𝐼 = 3.17 ∗ 10−9
2.29 ∗ 0.2555
𝜎=
3.17 ∗ 10−9
𝜎 = 184.5𝑀𝑃𝑎
Fibras neutras:
𝑀𝑦
𝜎=
𝐼
𝑏ℎ³
𝐼=
12
0.0054 ∗ (0.2417)³
𝐼=
12
𝐼 = 6.35 ∗ 10−6
2.29 ∗ 0
𝜎=
6.35 ∗ 10−6
𝜎 = 0 Pa
Empotramiento
Fibras a tención
M ∑ 𝑀𝐴 = 0
A
39.2(68𝑚𝑚) − 𝑀 = 0
68mm
𝑀 = 2.652𝑁𝑚
4kg
𝑏 ℎ3
𝐼=
12
5.4mm (0.2417𝑚)(0.0054𝑚)3
=
mm 12
= 3.805 ∗ 10−8 𝑚4
-Calculo práctico
𝑀𝑦
𝜎=
𝐼
2.652 ∗ 0.0054𝑚
𝜎=
2 ∗ 3.805 ∗ 10−8 𝑚4
𝜎 = 0.18𝑀𝑃𝑎
Fibras a Compresión
M
A ∑ 𝑀𝐴 = 0
68mm 39.2(68𝑚𝑚) − 𝑀 = 0
𝑀 = 2.652𝑁𝑚
2.5kg
5.4mm
𝑏 ℎ3
mm 𝐼=
12
(0.2417𝑚)(0.0054𝑚)3
=
12
= 3.805 ∗ 10−8 𝑚4
-Calculo práctico
𝑀𝑦
𝜎=
𝐼
2.652 ∗ 0.0054𝑚
𝜎=
2 ∗ 3.805 ∗ 10−8 𝑚4
𝜎 = −0.18𝑀𝑃𝑎
Fibras Neutras
M ∑ 𝑀𝐴 = 0
A
39.2(68𝑚𝑚) − 𝑀 = 0
68mm
𝑀 = 2.652𝑁𝑚
4kg
𝑏 ℎ3
𝐼=
12
241.7mm (0.0054𝑚)(0.2417𝑚)3
=
12
= 6.35 ∗ 10−6 𝑚4
-Calculo práctico
𝑀𝑦
𝜎=
𝐼
2.652 ∗ 0𝑐𝑚
𝜎=
2 ∗ 6.35 ∗ 10−6 𝑚4
𝜎 = 0 𝑃𝑎
Conclusiones
Cuando la línea neutra pasa por el strain gage observamos que el valor de “y” va a
ser igual a cero, ya que “y” es la distancia desde la LN hasta el strain gage. (Ana
Oña
Mediante el uso del strain gages comprobamos que las fibras sometidas a
compresión se registra un signo negativo, mientras que las fibras sometidas a
tracción poseen signo positivo.