MASTERFILL™ 300

Semi -flexible epoxy joint sealant

DESCRIPTION Vertical Holdup (paste) : 10 x 10 mm joint


MASTERFILL 300 is a semi-flexible, 100% solids epoxy MAF ±7%
joint sealant designed to protect joint edges and to Heat deflection temp : 12°C
prevent spalling due to traffic impact in control and relief
Shore D Hardness : 62
joints in concrete floors. MASTERFILL 300 may also be
used as a mortar binder for repairing concrete spalls. For MAF - Movement Accommodation Factor
tough slip or skid-resistant coatings, MASTERFILL 300 Test specimens were cured 7 days @23°C
may be applied with a broadcast of selected aggregates. Properties listed are typical and descriptive of the
It is available in pourable and paste grade. product, and may be used as a guide for determining
MASTERFILL 300 conforms to ACI 302.1R(4.10) Guide suitability for particular applications.
to concrete floor and slab construction.
PROPERTIES
RECOMMENDED FOR
Supply form : Pouring grade
MASTERFILL 300 is recommended areas such as; Paste grade
• low movement joints in manufacturing and
warehouse floors Colour : A wide range of colours
• filling saw-cut, relief and control joints Mix ratio (by volume) : Part A:Part B 1:1
• filling and sealing wire slots in concrete and asphalt Pot life (4L) : 25 to 30 min
pavement (eg. Inductive loop detectors).
• miscellaneous patching of concrete spalls APPLICATION
• use with BASF Construction Chemicals Mastertop
floors Surface preparation
• situations where spillage of diesel or chemicals To obtain maximum performance:
degrade traditional sealants. 1. Concrete should be well cured, at least 28 days old
and have a minimum compressive strength of
FEATURES AND BENEFITS 25MPa.
2. Joint surfaces must be dry and free from all
Flexible Flexibility at low temperature substance detrimental to the bonding of epoxy
with a lower brittle point than compounds and clean with no dust, oils,
normal epoxies. construction debris, laitance. Roughen with angle
Pre-portioned Easy application. grinder if in doubt.
packing Priming
Available in Match close to colour of floor. Priming is not required on dry surfaces. On wet or damp
selected range of surfaces, prime with Mastertop Primer 9
colours Placing
Achieves seamless Aesthetic. Joints: The mixed material should be applied by pouring
floor surfaces or knifing into joints that have a backing rod placed as
per diagram below.
Can be supplied Treated area easily
Using paste grade and knifing flush will produce
with a fugitive dye identifiable. No wasteful
seamless ramping or briding across joints. When coating
repetitive coatings or
with MASTERFILL 300 pourable, apply with trowel or
risk of untreated areas.
roller, with or without F1/F5 fillers to provide non skid
TYPICAL PERFORMANCE DATA textures and semi-resilient surfaces for enhanced work
environments.
Test at 23°C
Joint dimension: standard width to depth ratio will be
Tensile strength (ASTM D 638) : 3.4 to 5.5 MPa between 1:1 and 2:1.
Tensile elongation (ASTM D638) : 40 to 50% Minimum depth of MASTERFILL 300 s 12mm.
Impact resistance (Gardner-direct) : 18.1 Nm Use closed cell backing rods in joints with no gap
forming board to determine correct depth. In joints with
Bond to concrete (ASTM D 2240) : >2.5MPa board in place, debonding tape can be used.
(concrete failure)

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road – Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
MASTERFILL™ 300
Mixing ESTIMATING DATA
Mix only the amount of material that can be used before
the expiration of the pot life. Add 1 x 0.6kg of Mastertop
Litre per metre Metre run
X1 colour pack to part A and blend until uniform. Joint size (mm)
run per 10 L kit
(Should a deeper colour be required, add 2 x 0.6 kg of
Mastertop X1 colour packs in total). Mix each component 5x5 0.025 400
separately and then measure the components carefully. 10 x 20 0.100 100
Add hardener (Part B) to resin (Part A). Mix the 15 x 10 0.150 66.6
combined components of MASTERFILL 300 for a 20 x 10 0.200 50
minimum of 3 minutes using an electric drill powered 25 x 15 0.375 26.6
paint mixer. Carefully scrape the sides and bottom of the 30 x 15 0.450 22.2
container while mixing. Estimates do not take into consideration of material lost
during mixing and application.
CURING
PACKAGING
Thin film @23°C
Tak free time : 8 hours MASTERFILL 300 is available in :
Hard dry time : 12 hours 10 litre kits Part A - 4.7 L
Full cure time : 7 days Part B - 5.0 L
X1 colour pack - 0.6 kg (0.3L)
CLEANING
SHELF LIFE
Epoxies are much easier to clean up before they cure.
Remove excess material from surfaces and tools. MASTERFILL 300 can be kept for 12 months from date
Suitable solvents for this purpose are acetone, of manufacture in original unopened packaging, if stored
methylethyl ketone (MEK) or Toluene (all flammable); in enclosed area at temperatures between 4°C to 32°C.
and 1,1,1, trichloroethane (non flammable). Follow all
manufacturer's safety precautions and disposal PRECAUTIONS
procedures.
As with all epoxy products, wear protective overalls and
gloves - prolonged contact with skin should be avoided
as it could produce dermatitis, particular with people
whose skin may be sensitive to epoxy resin systems,
ensure adequate ventilation.
Do not attempt to split units unless accurate measuring
can be assured.
Do not use at temperatures of less than 8°C unless
artificial means of heating can be used to assist cure.
During cold weather Part A should be pre-warmed to
between 20 and 30°C.
Not to be used for conditions where fluctuations in
temperature exist eg -15°C to +15°C.
For detailed Health, Safety, Environmental
Recommendations, please consult and follow all
instructions on the product Material Safety Data Sheet.
Mfill300/02/0301

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.