SIPROTEC 7SA6 Distance Protection –

secure investment
for the future
SIPROTEC 7SA6 Distance Protection –
protecting, controlling and automating
at all voltage levels between 5 kV and 500 kV

The SIPROTEC® 7SA6 dis- Optimum protection at Automating a sub-


all voltage levels between station – simple, like in
tance protection relay is a
5 kV and 500 kV industry
universal device for protec- As a universal protection de- Even the basic variant of the
tion, control and automa- vice, the SIPROTEC 7SA6 dis- SIPROTEC 7SA6 distance pro-
tance protection relay can be tection relay includes extre-
tion on the basis of the implemented at all voltage mely flexible programmable
levels. Proven and 100% type- logics. This permits:
SIPROTEC 4 system. Its
tested function packages are • Interlocking check for the
high level of flexibility available for various appli- control unit / breaker
cation areas in resonant- • Additional protective circuits
means it can be implement- earthed, isolated-neutral or to protection functions
earthed-neutral systems. • Processing of measured
ed at all voltage levels. With
values with defined limiting
The distance protection func-
this device, you are ideally values
tion can be implemented with
equipped for the future: it different pickup methods that With the aid of the CFC editor,
are specifically tailored to the familiar from the world of
offers security of invest- various operating conditions. SIMATIC industrial automati-
You can choose between: on, the flexible opportunities
ment and also saves on op-
• Overcurrent pickup offered by the logic can be
erating costs. • Voltage and current- exploited to the full. With full-
dependent pickup graphics interface support and
• Voltage, current and phase- without any programming
This is facilitated by the
angle-dependent pickup knowledge, the logic swit-
following features:
• Impedance pickup ching elements can be selec-
• Tested protection modules
ted from a program library and
assure maximum safety Each pickup method assures
connected up on the PC. An
• Uniform operator software a particularly high degree of
ingenious consistency check
(DIGSI® 4) for all SIPROTEC protection selectivity, since
assures an error-free configu-
devices saves on training impedance measurement is
ration result and reliable ope-
costs possible in up to 6 measuring
ration.
• Clearly laid out measured- loops simultaneously. Further-
value display saves on more, SIPROTEC 7SA6 offers
external measuring many more functions for com-
instruments prehensive feeder protection
• DIGSI 4 start-up aids speed and uncomplicated operation.
up commissioning
• Integrated control unit
saves space and money
• Flexible communication
modules permit the use of
today's and future protocol
standards and give you
security of investment
• Service interface for
telecommunication reduces
maintenance and operating
costs

2
A family of Devices
– for any application
– for any installation location

More than 30,000 digital More than 20 years of experi-


distance protection ence in the development and
devices are already in use production of digital protection
and control equipment have
SIPROTEC 7SA6, the digital been incorporated into the
distance protection family wi- concept of the new family of
th control unit, is the logical devices. Powerful 32-bit
enhancement of the 7SA5 di- microprocessor systems
stance protection devices, enable us today to integrate
thousands of which are in use. number-crunching
protection algo-
rithms and pre-
ffuunnc A Alll
cise control ct
aavvaail tiioonnss aarre
technology in ilaabbl e
eennccl lee iinn aalll
one device. loossuure
vvaarria re
iannttss

3
DIGSI 4 –
easy to use

Switchgear control from DIGSI 4 – the uniform PC


remote of locally program for user-friendly
operation of all
The SIPROTEC 7SA6 distance
SIPROTEC 4 devices
protection relay enables the
breaker in the feeder to be DIGSI stands for convenient
controlled directly, taking the and user-friendly parameteri-
respective interlocking condi- zation and operation of digital
tions into account. protection equipment.
Particularly clear control is • Each window contains the
made possible by those de- information that is really
vices with a graphic display necessary – irrespective of
for displaying the feeder mim- the device you are in the
ic diagram, colored control process of configuring.
keys and 2 key switches. The • Context-sensitive menus
feeder mimic diagram can be for every situation offer you
easily designed and specific tailored functionality –
to the application with the aid there's no longer any need
of the PC program DIGSI 4. for complex searches
Those devices with a 4-line through menu hierarchies.
display also offer menu-driven • A matrix makes I/O
control. All device variants can configuration transparent.
be integrated into the remote- You can set up connections
control concepts of SCADA right through to the control
and protection systems. With and protection system with
SIPROTEC 7SA6, control com- just a single click of the
mands are executed reliably mouse.
and system faults cleared up Easy-to-use start-up aids
quickly and selectively at all offer safety and save
times. money.

4
Retrofittable communication Open communication Measurement and testing
modules are available for all standards functions
SIPROTEC 7SA6 distance pro-
tection devices. This means Communication by IEC proto- Integrated in the SIPROTEC
you can and will be able to col and PROFIBUS: the inter- 7SA6 distance protection relay
satisfy today's and future national, standardized inter- are a large number of meas-
requirements of different face defined in IEC 60870-5- urement and testing functions
communications protocols. At 103 has proven itself as an for commissioning and opera-
the same time, absolutely all open communications stand- tional measurements.
SIPROTEC devices can be ard for connecting protection
In addition to the usual meas-
operated via modem and/or equipment from different ven-
ured values taken for operating
star coupler and communicate dors. Alternatively, other forms
currents, voltages and power,
with higher-level control and of fieldbus interfacing, via
the equipment now also offers
protection systems such as PROFIBUS or other protocols,
min./max. values, demand val-
SICAM. are also available with
ues and energy metering.
SIPROTEC 4 – widely imple-
mented standards, particularly
in the fields of control and
protection systems and auto-
mation engineering.

5
Performance Characteristics
of the 7SA6 distance protection family

Function ANSI no. Function ANSI no.


Protection functions Protection functions
Trip mode • 3-pole only Thermal overload 49 • Prewarning stage and tripping stage
• 1-/3-pole protection • Measured values
Distance protection 21, 21N • 6-loop measurement Circuit-breaker failure protection 50BF • 2-stages with short reset times
Distance-protection • Overcurrent I> Control
pickup method • Undervoltage/overcurrent U/I
• Undervoltage/overcurrent/ Control function • Number of controllable switching
angle U/I/ϕ devices dependent only on
• Impedance Z the number of inputs and outputs
Teleprotection schemes 85–21 • Permissive trip PUTT, POTT available
for distance protection • Blocking, Unblocking • Extensive choice of all common
• Reverse interlocking single and double commands/alarms
• Pilot wire comparison • Interlocking by means of freely
via DC loop programmable logic
• Multi-end applications Feeder control display • Freely programmable
Remote intertripping • Direct breaker intertripping Programmable keys • 4 function keys
via binary input DUTT • Control keys
Weak infeed 27WI • Echo Programmable logic
protection • Tripping on carrier reception
• All common logic functions with
and U<
CFC software via PC
Fault locator FL • Optionally with load-current
• Processing of interlock and
compensation
protection signals
• Fault location display on device
via DIGSI, via system interface, Additional functions
via 20 mA analog output, BCD Automatic reclosing 79 • Up to 8 reclosing cycles
Parallel-line – • For distance measurement With/without action time
compensation for and fault locator control
overhead lines • ADT (= adaptive dead time
Power-swing 68 • Blocking the distance protection control)
detection 68T • Tripping on loss of • RDT (= reduced dead time
synchronism control)
Directional earth-fault 50N • Definite-time overcurrent • DLC (= dead line check)
protection for earthed- 51N • Inverse time overcurrent, various Synchrocheck 25 • Measurement of ∆U, ∆f, ∆ϕ
system starpoints 67N characteristics Tripping circuit 74TC • Optional with 1 or 2 inputs
• U0 inverse monitoring • 1 or 3 tripping circuits
• Direction determination with U0, IY, U2-I2 Lock-out 86 • Reclosing after final tripping
• 4-stages only after special reset
Teleprotection schemes 85–67N • Directional comparison command
for directional earth- • Blocking, Unblocking Fault recording • Analog channels, customer-
fault protection • Multi-end applications specific choice of digital channels
Earth-fault protection • Earth-fault direction with
for resonant-earthed/ wattmetric measurement principle Measured values
isolated-neutral system • Measured earth-fault values Measured values • Extensive choice of operat. measured
starpoints • Transient-earth-fault meas. principle values, measuring accuracy <1%
with supplementary device 7SN60 • Energy metering
Overcurrent-time 50, 51 • As emergency function for failure • Energy metering with meter-pulse
protection 50N, 51N of measuring-circuit voltage or processing
running in parallel with dist. protect. • Min./max. values
• Definite-time overcurrent • Demand values
• Inverse time, various characteristics Communication
Voltage protection 27, 59 • Phase/positive-sequence
overvoltage U> Communication • 1 IRIG-B time-sync. input
• Phase/positve-sequence • 1 RS232/RS485 serial interface,
undervoltage U< at rear, electrically isolated
• Negative-sequence overvoltage U2> • 2 serial interfaces, at rear,
• Zero-sequence overvoltage 3U0> electricalor optical, variable
with plug-in communication
modules
• 1 RS232 serial interface,
at front

Siemens AG
Power Transmission and Distribution Group
Protection and Substation Control
Systems Division
P.O. Box 48 06
D-90026 Nuremberg
www.ev.siemens.de
Power
to the
Subject to change without prior notice
Siemens Aktiengesellschaft Order No. E50001-U321-A153-X-7600
Printed in Germany
Dispo-Stelle 06200
61D6254 Ra/Sö 101671 03005.